Mao Z, Bleiel H, Beuer F, Böse MWH, Soetebeer M. Occlusal changes on implant-supported single crowns with one year follow-up after loading: A systematic review and meta-analysis. J Dent 2024; 146:105000. [PMID: 38734300 DOI: 10.1016/j.jdent.2024.105000] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Accepted: 04/17/2024] [Indexed: 05/13/2024] Open
Abstract
OBJECTIVE This systematic review evaluated the occlusal changes after loading with implant-supported single crowns. SOURCES An electronic literature search was conducted in PubMed, Embase and Cochrane library for randomized (RCTs) or non-randomized controlled clinical trials (CCTs), with a minimum of 10 patients. STUDY SELECTION Studies reporting the occlusal force changes on implant-supported single crowns - with natural teeth as antagonist - measured at baseline and after loading periods were included. 4 CCTs including 133 ISCs in posterior sites were included for meta-analysis. All analyzed ISCs had no contact at a light bite and a light contact at a heavy bite in MIP at loading (baseline). DATA The relative occlusal forces (ROFs) of each implant-supported single crown (ISC) or control tooth (CT) were extracted. ROFs were defined as percentage of the total occlusal force of the entire dentition at maximum intercuspal position (MIP). A meta-analysis was conducted to compare the ROF changes at different follow-up periods and the weighted mean differences in ROF between ISCs and CTs were pooled and analyzed. The amount of change in ROF was significantly lower in 6 to 12 months after loading comparing the follow-up period between baseline and 6 month (p < 0.05). At baseline and 3-month follow-up, CTs presented significant higher ROF than ISCs (p < 0.05), while no significant difference was found after half year following. CONCLUSIONS This study showed that the ROF changes significantly over time after loading of ISCs. It might prove that the occlusal concept defined at the time of prosthetic delivery changes or adapts naturally over time. CLINICAL SIGNIFICANCE The function of specific implant occlusal concept (no contact at a light bite and a light contact at a heavy bite in MIP) is limited over time and careful monitoring and occlusal adjustments should be recommendable during the first-year follow-up.
Collapse
Affiliation(s)
- Zhen Mao
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4-6, 14197 Berlin, Germany.
| | - Hannah Bleiel
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4-6, 14197 Berlin, Germany
| | - Florian Beuer
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4-6, 14197 Berlin, Germany
| | - Mats Wernfried Heinrich Böse
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4-6, 14197 Berlin, Germany
| | - Maren Soetebeer
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4-6, 14197 Berlin, Germany
| |
Collapse
|
2
|
Balel Y, Grillo R. The past forty-three years of dental implantology literature. A global mapping and scientometric analysis. JOURNAL OF STOMATOLOGY, ORAL AND MAXILLOFACIAL SURGERY 2024:101945. [PMID: 38857690 DOI: 10.1016/j.jormas.2024.101945] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2023] [Revised: 06/06/2024] [Accepted: 06/07/2024] [Indexed: 06/12/2024]
Abstract
PURPOSE The aim of this research is to make a scientometric analysis of the dental implantology literature and to present the results in a more understandable way to the reader by visualizing them with maps. METHODS The dental implantology literature was accessed through the Web of Science database. Scientometric data was obtained with Citespace 6.1 software, co-citation, clustering analysis, citation burst, and mapping analyzes were performed. Scimago Graphica software was used for additional visualizations. RESULTS A total of 35,704 articles were included in the analysis. There were 88,616 authors, 72,333 institutes, 142 countries/regions, and 3,265 journals contributing to the dental implantology literature. The United States was first with 7,334 publications and 225,868 citations. The literature between 1980 and 2023 was divided into 19 different clusters, and the literature between 2000 and 2023 was divided into 16 different clusters. CONCLUSIONS Key themes in the field include the use of autogenous bone, advancements in implant surface technology, and the use of platform switching and intraoral scanners. Emerging topics of interest include esthetic considerations in the treatment of the anterior region, stress distribution, the use of zirconia, and the impact of implant treatment on oral health-related quality of life. With similar scientometric analysis studies to be done in the future, the progress of the literature can be followed on the basis of evidence.
Collapse
Affiliation(s)
- Yunus Balel
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Tokat Gaziosmanpasa University, Merkez, Tokat 60030, Turkey.
| | - Ricardo Grillo
- Department of Oral & Maxillofacial Surgery, Traumatology and Prosthesis - Faculty of Dentistry of the University of São Paulo, Brazil; Department of Oral & Maxillofacial Surgery, Faculdade Patos de Minas, Brasília, Brazil
| |
Collapse
|
3
|
Steyer E, Theisen K, Hulla H, Ubaidha Maheen C, Sokolowski A, Lorenzoni M. Eleven- to fifteen-year outcome for two-piece implants with an internal tube-in-tube connection: a cross-sectional analysis of 245 implants. Oral Maxillofac Surg 2024; 28:859-867. [PMID: 38315402 DOI: 10.1007/s10006-024-01215-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 01/19/2024] [Indexed: 02/07/2024]
Abstract
PURPOSE The aim of this retrospective study was to evaluate the outcomes of a two-piece implant system with a tube-in-tube internal connection after up to 15 years of clinical use. MATERIAL AND METHODS A retrospective follow-up examination of patients treated with internal tube-in-tube implants between 2003 and 2006 was conducted. The implant survival rates, peri-implant conditions (marginal bone loss, bleeding on probing, plaque index, probing depth), and technical complications were determined. RESULTS In total, 312 dental implants were placed in 152 patients. Of the original 152 patients enrolled, 245 implants in 112 patients were available for a follow-up evaluation after 11 to 15 years (mean observation time, 12.9 ± 1.1 years). The overall implant survival rate was 93.9%. Outcomes for MBL (1.49 ± 1.23 mm), PI (24.3 ± 22.2%), BOP (18.3 ± 28.7%), and PD (2.74 ± 1.21 mm) were observed. Selected parameters (time after implant surgery, smoking habits, bone augmentation (GBR)) showed an influence on MBL and PD. CONCLUSIONS The internal tube-in-tube implant system showed favorable long-term results. The correlation of MBL and PD with the patient-specific factor smoking habit is in accordance with other studies. CLINICAL RELEVANCE Camlog Root-Line implants with a tube-in-tube implant-abutment connection and a 1.6-mm polished neck configuration have demonstrated favorable long-term outcomes in daily clinical practice. However, it is important to note that these implants are no longer available on the market.
Collapse
Affiliation(s)
- Elisabeth Steyer
- Division of Operative Dentistry, Periodontology and Prosthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, Billrothgasse 4, 8010, Graz, Austria
| | - Kerstin Theisen
- Division of Operative Dentistry, Periodontology and Prosthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, Billrothgasse 4, 8010, Graz, Austria.
| | - Helfried Hulla
- Division of Operative Dentistry, Periodontology and Prosthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, Billrothgasse 4, 8010, Graz, Austria
- Private Practice Straß, Graz, Austria
| | - Ceeneena Ubaidha Maheen
- Division of Operative Dentistry, Periodontology and Prosthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, Billrothgasse 4, 8010, Graz, Austria
| | - Alwin Sokolowski
- Division of Operative Dentistry, Periodontology and Prosthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, Billrothgasse 4, 8010, Graz, Austria
| | - Martin Lorenzoni
- Division of Operative Dentistry, Periodontology and Prosthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, Billrothgasse 4, 8010, Graz, Austria
| |
Collapse
|
4
|
Hosseini M, Worsaae N, Gotfredsen K. SURVIVAL RATE OF IMPLANT-SUPPORTED, SINGLE-TOOTH RESTORATIONS BASED ON ZIRCONIA OR METAL ABUTMENT IN PATIENTS WITH TOOTH AGENESIS: A 5-YEARS PROSPECTIVE CLINICAL STUDY. J Evid Based Dent Pract 2024; 24:101970. [PMID: 38821661 DOI: 10.1016/j.jebdp.2024.101970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Revised: 12/22/2023] [Accepted: 01/13/2024] [Indexed: 06/02/2024]
Abstract
OBJECTIVES The primary aim was to investigate survival rate of zirconia versus metal abutments, and the secondary aim was clinical outcomes of all-ceramic versus metal-ceramic crowns on single-tooth implants. METHODS Patients with tooth-agenesis participated to previously published prospective clinical study with 3-year follow-up were recalled after 5 years. Biological variables included survival and success rate of implants, marginal bone level, modified Plaque and Sulcus Bleeding Index and biological complications. Technical variables included restoration survival rate, marginal adaptation and technical complications. The aesthetic outcome of crowns and peri-implant mucosa in addition to patient-reported outcome were recorded. Descriptive analysis, linear mixed model for quantitative data, or generalized linear mixed model for ordinal categorical data were applied; significance was set to 0.05. RESULTS Fifty-three patients (mean age: 32.4 years), with 89 implants participated to the 5-years examination. The implants supported 50 zirconia abutments with 50 all-ceramic (AC) crown and 39 metal abutments with 29 metal-ceramic (MC) and 10 AC crowns. The Implant and restoration survival rate was 100% and 96%, respectively. No clinically relevant biological difference between implants supporting metal or zirconia abutments was registered. The technical complications were veneering fracture of AC-crowns (n = 3), crown loosening of MC-crowns (n = 4) and one abutment screw loosening (MC-crown on metal abutment). MC-crowns had significantly better marginal adaptation than AC-crowns (p = .01). AC-crowns had significantly better color and morphology than MC-crowns (p = .01). CONCLUSIONS Zirconia-based single-tooth restorations are reliable alternative materials to metal-based restorations with favorable biological and aesthetic outcome, and few technical complications.
Collapse
Affiliation(s)
- Mandana Hosseini
- Section of Oral Rehabilitation, Department of Odontology, Faculty of Health Science, University of Copenhagen, Copenhagen N-2200, Denmark.
| | - Nils Worsaae
- Department of Oral and Maxillofacial Surgery, University Hospital, Rigshospitalet, Copenhagen, Denmark
| | - Klaus Gotfredsen
- Section of Oral Rehabilitation, Department of Odontology, Faculty of Health Science, University of Copenhagen, Copenhagen N-2200, Denmark
| |
Collapse
|
5
|
Back LS, Silva J, Morsch CS, Tumedei M, Magini RDS, Piatelli A, Benfatti CAM. Clinical Performance of 170 Frictional Morse Taper Implants: 2 Years Follow-Up. J ORAL IMPLANTOL 2024; 50:127-135. [PMID: 38530824 DOI: 10.1563/aaid-joi-d-23-00054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/28/2024]
Abstract
This study evaluated the clinical survival rates of 170 Morse taper implants through clinical and mechanical parameters in different therapeutic approaches such as single crowns, fixed partial prostheses, and fixed full-arch prostheses. Patients referred to the Center on Education and Research on Dental Implants from May 2017 to July 2018 with the indication for dental implant therapy, aged >18 years, without periodontal disease, recent evidence of inflammatory activity or other oral disorders, current pregnancy, uncontrolled diabetes mellitus or heavy smoking habit were included in this study. After 12 weeks of healing since the implants were placed in the mandible and after 16 weeks following implants placed in the maxilla, patients returned to the Center for prosthetic rehabilitation. After implant therapy, all patients underwent periodical, clinical, and prosthetic examinations every 6 months. Prosthetic restorations involved 109 fixed reconstructions in function. Few prosthetic complications were reported (6.55%). Twenty implants were rehabilitated with cemented prostheses; from those, 1 crown suffered a loss in retention/decementation. Of the 148 implants rehabilitated with screwed-retained prostheses, 6.76% suffered prosthetic screw loosening. The cumulative implant survival rate was 98.2%. When peri-implant tissue health was evaluated, the keratinized mucosa band appeared related to peri-implant tissue stability. Thus, Morse taper implants represented a successful procedure for implant rehabilitation, with a high cumulative implant survival rate, low prevalence of biological and prosthetic complications, and good stability of peri-implant tissues over the assessed period.
Collapse
Affiliation(s)
- Lara Steiner Back
- Department of Dentistry, Center for Education and Research on Dental Implants (CEPID), Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
| | - Joseane Silva
- Department of Dentistry, Center for Education and Research on Dental Implants (CEPID), Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
| | - Carolina Schäffer Morsch
- Department of Dentistry, Center for Education and Research on Dental Implants (CEPID), Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
| | - Margherita Tumedei
- Department of Biomedical, Surgical and Dental Sciences, State University of Milano, Milano, Italy and IRCCS, Fondazione Ca' Granda, IRCCS Ospedale Maggiore Policlinico, Milano, Italy
| | - Ricardo de Souza Magini
- Department of Dentistry, Center for Education and Research on Dental Implants (CEPID), Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
| | - Adriano Piatelli
- School of Dentistry, Saint Camillus International University for Health Sciences (Unicamillus), Rome, Italy and Facultad de Medicina, Universidad Catolica San Antonio de Murcia, Murcia Spain
| | - Cesar Augusto Magalhães Benfatti
- Department of Dentistry, Center for Education and Research on Dental Implants (CEPID), Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
| |
Collapse
|
6
|
Donker VJJ, Raghoebar GM, Slagter KW, Hentenaar DFM, Vissink A, Meijer HJA. Immediate implant placement with immediate or delayed provisionalization in the maxillary aesthetic zone: A 10-year randomized trial. J Clin Periodontol 2024; 51:722-732. [PMID: 38454548 DOI: 10.1111/jcpe.13971] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 02/07/2024] [Accepted: 02/21/2024] [Indexed: 03/09/2024]
Abstract
AIM To compare the marginal bone level of immediately placed implants, with either immediate or delayed provisionalization (IP or DP), in the maxillary aesthetic zone after 10 years of function. MATERIALS AND METHODS Participants with a failing tooth in the maxillary aesthetic zone were randomly assigned to immediate implant placement with either IP (n = 20) or DP (n = 20) after primary wound closure with a free gingival graft. The final restoration was placed 3 months after provisionalization. The primary outcome was change in marginal bone level. In addition, implant survival, restoration survival and success, peri-implant tissue health, mucosa levels, aesthetic indices, buccal bone thickness and patient satisfaction were evaluated. RESULTS After 10 years, the mean mesial and distal changes in marginal bone level were -0.47 ± 0.45 mm and -0.49 ± 0.52 mm in the IP group and -0.58 ± 0.76 mm and -0.41 ± 0.72 mm in the DP group (p = .61; p = .71). The survival rate was 100% for the implants; for the restorations, it was 88.9% in the IP group and 87.5% in the DP group. Restoration success, according to modified USPHS criteria, was 77.8% in the IP group and 75.0% in the DP group. The prevalence of peri-implant mucositis was 38.9% and 35.7% and of peri-implantitis 0.0% and 6.3%, respectively, in the IP group and DP group (p = 1.0; p = .40). The Pink Esthetic Score and White Esthetic Score was 15.28 ± 2.32 in the IP group and 14.64 ± 2.74 in the DP group, both clinically acceptable (p = .48). The buccal bone thickness was lower in the DP group. Patient satisfaction was similar in both groups (p = .75). CONCLUSIONS The mean marginal bone level changes after immediate implant placement with IP were similar to those after immediate placement with DP. CLINICAL TRIAL REGISTRATION Registered in the National Trial Register (NL9340).
Collapse
Affiliation(s)
- Vincent J J Donker
- Department of Oral and Maxillofacial Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Gerry M Raghoebar
- Department of Oral and Maxillofacial Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Kirsten W Slagter
- Department of Oral and Maxillofacial Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Diederik F M Hentenaar
- Department of Oral and Maxillofacial Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Arjan Vissink
- Department of Oral and Maxillofacial Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Henny J A Meijer
- Department of Oral and Maxillofacial Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
- Department of Restorative Dentistry, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| |
Collapse
|
7
|
Deste Gökay G, Oyar P, Gökçimen G, Durkan R. Static and dynamic stress analysis of different crown materials on a titanium base abutment in an implant-supported single crown: a 3D finite element analysis. BMC Oral Health 2024; 24:545. [PMID: 38730391 PMCID: PMC11088090 DOI: 10.1186/s12903-024-04328-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Accepted: 05/03/2024] [Indexed: 05/12/2024] Open
Abstract
BACKGROUND This Finite Element Analysis was conducted to analyze the biomechanical behaviors of titanium base abutments and several crown materials with respect to fatigue lifetime and stress distribution in implants and prosthetic components. METHODS Five distinct designs of implant-supported single crowns were modeled, including a polyetheretherketone (PEEK), polymer-infiltrated ceramic network, monolithic lithium disilicate, and precrystallized and crystallized zirconia-reinforced lithium silicates supported by a titanium base abutment. For the static load, a 100 N oblique load was applied to the buccal incline of the palatal cusp of the maxillary right first premolar. The dynamic load was applied in the same way as in static loading with a frequency of 1 Hz. The principal stresses in the peripheral bone as well as the von Mises stresses and fatigue strength of the implants, abutments, prosthetic screws, and crowns were assessed. RESULTS All of the models had comparable von Mises stress values from the implants and abutments, as well as comparable maximum and minimum principal stress values from the cortical and trabecular bones. The PEEK crown showed the lowest stress (46.89 MPa) in the cervical region. The prosthetic screws and implants exhibited the highest von Mises stress among the models. The lithium disilicate crown model had approximately 9.5 times more cycles to fatique values for implants and 1.7 times more cycles to fatique values for abutments than for the lowest ones. CONCLUSIONS With the promise of at least ten years of clinical success and favorable stress distributions in implants and prosthetic components, clinicians can suggest using an implant-supported lithium disilicate crown with a titanium base abutment.
Collapse
Affiliation(s)
- Gonca Deste Gökay
- Department of Prosthodontics, Faculty of Dentistry, Bursa Uludag University, Bursa, Türkiye.
| | - Perihan Oyar
- Dental Prosthetics Technology, School of Health Services, Hacettepe University, Ankara, Türkiye
| | - Gülsüm Gökçimen
- Department of Prosthodontics, Ankara 75Th Year Oral and Dental Health Hospital, Ankara, Türkiye
| | - Rukiye Durkan
- Department of Prosthodontics, Faculty of Dentistry, Istanbul Okan University, Istanbul, Türkiye
| |
Collapse
|
8
|
Kohal RJ, Riesterer E, Vach K, Patzelt SBM, Iveković A, Einfalt L, Kocjan A, Hillebrecht AL. Fracture Resistance of a Bone-Level Two-Piece Zirconia Oral Implant System-The Influence of Artificial Loading and Hydrothermal Aging. J Funct Biomater 2024; 15:122. [PMID: 38786633 PMCID: PMC11122605 DOI: 10.3390/jfb15050122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Revised: 04/24/2024] [Accepted: 05/04/2024] [Indexed: 05/25/2024] Open
Abstract
Preclinical and clinical research on two-piece zirconia implants are warranted. Therefore, we evaluated the in vitro fracture resistance of such a zirconia oral implant system. The present study comprised 32 two-piece zirconia implants and abutments attached to the implants using a titanium (n = 16) or a zirconia abutment screw (n = 16). Both groups were subdivided (n = 8): group T-0 comprised implants with a titanium abutment screw and no artificial loading; group T-HL was the titanium screw group exposed to hydro-thermomechanical loading in a chewing simulator; group Z-0 was the zirconia abutment screw group with no artificial loading; and group Z-HL comprised the zirconia screw group with hydro-thermomechanical loading. Groups T-HL and Z-HL were loaded with 98 N and aged in 85 °C hot water for 107 chewing cycles. All samples were loaded to fracture. Kruskal-Wallis tests were executed to assess the loading/bending moment group differences. The significance level was established at a probability of 0.05. During the artificial loading, there was a single occurrence of an implant fracture. The mean fracture resistances measured in a universal testing machine were 749 N for group T-0, 828 N for group Z-0, 652 N for group T-HL, and 826 N for group Z-HL. The corresponding bending moments were as follows: group T-0, 411 Ncm; group Z-0, 452 Ncm; group T-HL, 356 Ncm; and group Z-HL, 456 Ncm. There were no statistically significant differences found between the experimental groups. Therefore, the conclusion was that loading and aging did not diminish the fracture resistance of the evaluated implant system.
Collapse
Affiliation(s)
- Ralf J. Kohal
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (E.R.)
| | - Ellen Riesterer
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (E.R.)
| | - Kirstin Vach
- Medical Center—University of Freiburg, Institute of Medical Biometry and Statistics, Faculty of Medicine, University of Freiburg, 79104 Freiburg, Germany;
| | - Sebastian B. M. Patzelt
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (E.R.)
- Private Dental Clinic, 78658 Zimmern ob Rottweil, Germany
| | - Aljaž Iveković
- Department for Nanostructured Materials, Jožef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia; (A.I.); (L.E.)
| | - Lara Einfalt
- Department for Nanostructured Materials, Jožef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia; (A.I.); (L.E.)
- Jožef Stefan International Postgraduate School, Jamova 39, 1000 Ljubljana, Slovenia
| | - Andraž Kocjan
- Department for Nanostructured Materials, Jožef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia; (A.I.); (L.E.)
| | - Anna-Lena Hillebrecht
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany; (E.R.)
| |
Collapse
|
9
|
Raghoebar GM, Meijer HJA, Vissink A. Immediate repair of bony defects in the posterior mandibular region following removal of a fractured implant: a feasible treatment? Int J Oral Maxillofac Surg 2024; 53:430-435. [PMID: 38061953 DOI: 10.1016/j.ijom.2023.11.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 11/24/2023] [Accepted: 11/28/2023] [Indexed: 04/16/2024]
Abstract
The aim of this study was to assess whether immediate bone reconstruction after removal of a fractured dental implant in the posterior mandible provides a sound base for implant replacement, with a favourable treatment outcome and high patient satisfaction. Eight consecutive patients with a fractured implant neck were included. The implant was removed via osteotomy, following which the site was immediately repaired with a mixture of autogenous bone and bone substitute. After a 4-month healing period, sufficient bone and favourable soft tissue conditions were present, allowing implant placement with adequate primary stability. After a further 3 months, the implants were restored with an all-ceramic restoration. Patient satisfaction, the aesthetic outcome, complications, and postoperative morbidity were assessed using standardized clinical and radiographic examinations up to 5 years after crown placement. No implant failures were observed during the follow-up. Plaque accumulation, the presence of calculus, bleeding tendency, and peri-implant inflammation indices were low, indicating healthy peri-implant conditions. The mean marginal bone level change at the 5-year follow-up was - 0.17 ± 0.46 mm. All patients reported a high level of satisfaction (mean overall score 9.3 ± 0.5). In conclusion, immediate reconstruction of the hard tissue after removal of a fractured dental implant is a viable treatment option. This approach facilitates rehabilitation, reduces morbidity, and leads to favourable aesthetic outcomes.
Collapse
Affiliation(s)
- G M Raghoebar
- Department of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands.
| | - H J A Meijer
- Department of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands; Department of Implant Dentistry, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - A Vissink
- Department of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| |
Collapse
|
10
|
Chittavoravanich N, Jirajariyavej B, Bencharit S, Thanasrisuebwong P. Comparison of Four Different Dental Implant Removal Techniques in Terms of the Weight and Volume of Bone Loss. Cureus 2024; 16:e61104. [PMID: 38919230 PMCID: PMC11197631 DOI: 10.7759/cureus.61104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/26/2024] [Indexed: 06/27/2024] Open
Abstract
PURPOSE Several approaches have been suggested for implant removal. However, further research is necessary to review data regarding the amount of bone removed and the duration of removal time for different procedures. This study evaluates and compares various implant removal techniques. Materials and methods: A polyurethane block was scanned to create an implant surgical guide. Afterward, implant-guided surgery was performed on 60 simulated bone blocks. The implants were then separated into four groups and removed utilizing the counter-torque ratchet, trephine drills, burs, and piezosurgery. RESULTS For the weight of bone loss, there were significant differences in the median between the counter-torque ratchet technique (CTRT) and trephine (p < 0.01), CTRT and bur (p < 0.01), trephine and piezo (p < 0.01), and bur and piezo (p = 0.04). All groups, except CTRT and the piezo group, demonstrated a statistically significant difference (p < 0.01) in the procedure durations. Regarding the volume of bone loss, a statistically significant difference (p < 0.01) was found between each group. Conclusions: CTRT showed the least amount of bone loss. On the other hand, the trephine technique was demonstrated to be the fastest. It is essential to consider the limitations and risks when choosing the approach for implant removal.
Collapse
Affiliation(s)
| | | | - Sompop Bencharit
- Workman School of Dental Medicine, High Point University, High Point, USA
| | | |
Collapse
|
11
|
Parreira GJG, de Araújo Nobre MA, Moreira AGCR, Luís HPS. Limosilactobacillus reuteri as an Adjuvant in the Treatment of Peri-implant Mucositis in Total Rehabilitation: An Exploratory Study. Eur J Dent 2024; 18:610-618. [PMID: 38555646 PMCID: PMC11132781 DOI: 10.1055/s-0043-1777822] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/02/2024] Open
Abstract
OBJECTIVES Mechanical debridement is the traditional method for the treatment of peri-implant mucositis (P-im) and its success depends on the patient's correct oral hygiene. It is believed that probiotics may help by their ability to modulate the oral biofilm, resulting in anti-inflammatory and antibacterial plaque action. The aim of this study was to evaluate the adjuvant effect of the probiotic Limosilactobacillus reuteri (LR) in the mechanical treatment of P-im. MATERIALS AND METHODS This exploratory study included 29 subjects with implant-supported total rehabilitation and P-im, divided into test (TG) and control (CG) groups, equally subjected to professional mechanical debridement, with the administration of a daily GUM PerioBalance lozenge for 30 days added to the TG. The modified Plaque Index (mPlI) modified Sulcus Bleeding Index (mBI) and pocket depth (PD) were evaluated before the intervention (baseline) and 6 and 10 weeks later. STATISTICAL ANALYSIS Parametric and nonparametric tests with 5% significance level were used in the statistical analysis, using IBM SPSS Statistics 27.0 software. RESULTS Both treatments resulted in reduced mPlI, mBI, and PD at 6 weeks; while from 6 to 10 weeks there was an increase in mPlI and mBI and maintenance of PD. Compared with baseline, differences were close to statistical significance in the reduction in PD at 10 weeks in the CG (p = 0.018), after Bonferroni correction, and statistically significant in the mPlI at 6 weeks in the CG (p = 0.004) and in the TG (p = 0.002) as well as at 10 weeks in the TG (p = 0.016). Comparing the groups in the postintervention assessments, no statistically significant differences were found. CONCLUSION LR adjuvant mechanical treatment of P-im does not show a clear benefit compared with mechanical treatment alone, with both interventions achieving similar clinical results. Further prospective and long-term studies are needed.
Collapse
Affiliation(s)
- Gonçalo J G Parreira
- Universidade de Lisboa, Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Lisboa, Portugal
- Oral Hygiene Department, Maló Clinic, Lisbon, Portugal
- Universidade de Lisboa, Faculdade de Medicina Dentária, Rede de Higienistas Orais para o Desenvolvimento da Ciência (RHODes), Lisboa, Portugal
| | - Miguel A de Araújo Nobre
- Oral Hygiene Department, Maló Clinic, Lisbon, Portugal
- Research and Development Department, Maló Clinic, Lisbon, Portugal
- Clínica Universitária de Estomatologia, Faculdade de Medicina, Universidade de Lisboa, Portugal
| | - André G C R Moreira
- Universidade de Lisboa, Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Lisboa, Portugal
| | - Henrique P S Luís
- Universidade de Lisboa, Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Lisboa, Portugal
- Universidade de Lisboa, Faculdade de Medicina Dentária, Rede de Higienistas Orais para o Desenvolvimento da Ciência (RHODes), Lisboa, Portugal
- Center for Innovative Care and Health Technology (ciTechcare), Polytechnic of Leiria, Leiria, Portugal
| |
Collapse
|
12
|
Wach T, Okulski J, Zieliński R, Trybek G, Michcik A, Kozakiewicz M. New Radiological Corticalization Index as an Indicator of Implant Success Rate Depending on Prosthetic Restoration-5 Years of Follow-Up. Diagnostics (Basel) 2024; 14:867. [PMID: 38732281 PMCID: PMC11083295 DOI: 10.3390/diagnostics14090867] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2024] [Revised: 04/17/2024] [Accepted: 04/19/2024] [Indexed: 05/13/2024] Open
Abstract
The new Radiological Corticalization Index (CI) is an indicator that describes bone remodeling near the dental implant's neck at the pixel level and is not visible to the naked eye. The aim of this research was to evaluate the correlation between the CI and bone remodeling using only radiographic (RTG) images. RTG samples were divided into groups depending on prosthetic restoration; the implant neck area around dental implants was examined, and texture features of the RTG images were analyzed. The study also investigated the type of prosthetic restoration and its influence as a factor on bone structure. The statistical analysis included evaluating feature distribution, comparing means (t-test) or medians (W-test), and performing a regression analysis and one-way analysis of variance or the Kruskal-Wallis test, as no normal distribution or between-group variance was indicated for the significant differences in the investigated groups. Differences or relationships were considered statistically significant at p < 0.05. The research revealed correlations between single crowns, overdenture restoration, bridge restoration, platform switching, prosthetic fracture, CI, and also marginal bone loss where p was lower than 0.05. However, the corticalization phenomenon itself has not yet been fully explored. The findings suggest that, depending on the type of prosthetic restoration, the corticalization index may correlate with marginal bone loss or not. Further research is necessary, as the index is suspected to not be homogeneous.
Collapse
Affiliation(s)
- Tomasz Wach
- Department of Maxillofacial Surgery, Medical University of Lodz, 113 Żeromskiego Str., 90-549 Lodz, Poland; (J.O.); (R.Z.); (M.K.)
| | - Jakub Okulski
- Department of Maxillofacial Surgery, Medical University of Lodz, 113 Żeromskiego Str., 90-549 Lodz, Poland; (J.O.); (R.Z.); (M.K.)
| | - Rafał Zieliński
- Department of Maxillofacial Surgery, Medical University of Lodz, 113 Żeromskiego Str., 90-549 Lodz, Poland; (J.O.); (R.Z.); (M.K.)
| | - Grzegorz Trybek
- Department of Oral Surgery, Pomeranian Medical University in Szczecin, 70-111 Szczecin, Poland;
- 4th Military Clinical Hospital in Wroclaw, ul. Rudolfa Weigla 5, 50-981 Wroclaw, Poland
| | - Adam Michcik
- Department of Maxillofacial Surgery, Medical University of Gdansk, Mariana Smoluchowskiego 17, 80-214 Gdansk, Poland;
| | - Marcin Kozakiewicz
- Department of Maxillofacial Surgery, Medical University of Lodz, 113 Żeromskiego Str., 90-549 Lodz, Poland; (J.O.); (R.Z.); (M.K.)
| |
Collapse
|
13
|
Alqutaibi AY, Alghauli MA, Almuzaini SA, Alharbi AF, Alsani AA, Mubarak AM, Alhajj MN. Failure and complication rates of different materials, designs, and bonding techniques of ceramic cantilever resin-bonded fixed dental prostheses for restoring missing anterior teeth: A systematic review and meta-analysis. J ESTHET RESTOR DENT 2024. [PMID: 38623053 DOI: 10.1111/jerd.13238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2024] [Revised: 03/30/2024] [Accepted: 04/03/2024] [Indexed: 04/17/2024]
Abstract
OBJECTIVES The objective of this review was to assess clinical trials that have examined the materials, design, and bonding of ceramic cantilevered resin-bonded fixed dental prostheses (RBFDPs) as a potential option for replacing missing anterior teeth. The evaluation primarily focuses on the rate of restoration failure and clinical complications. MATERIALS AND METHODS A thorough search of databases including PubMed/MEDLINE, Scopus, and the Cochrane Library, was conducted. The most recent search was performed in October 2023. Clinical studies that compared ceramic cantilevered RBFDPs with double retainers or cantilevered RBFDPs using different ceramic materials or bonding systems were included. The outcome measures considered were restoration failure and complication rates. RESULTS Twelve studies met the eligibility criteria. The pooled data showed a statistically significant decrease in complication events when using cantilever designs compared with double retainer designs (p < 0.05); however, there were no differences found between the two designs in terms of restoration failure. The complication and failure rate of cantilever RBFDPs did not show a statistically significant difference with or without ceramic primer application before luting with phosphate monomer-containing luting resin (p > 0.05). CONCLUSIONS Ceramic cantilevered RBFDPs have lower complication rates compared with those with double retainers. The use of a ceramic primer prior to luting composite resin for ceramic cantilevered RBFDPs decreases the occurrence of complications and failures, although this effect was not statistically significant. Additional research is required to confirm these findings. Glass ceramic cantilever RBFDPs showed a decrease in success after 6 years, requiring ongoing monitoring, but both zirconia and glass-infiltrated alumina cantilever RBFDPs have demonstrated durability with excellent long-term success and survival rates for up to 10 and 15 years. CLINICAL SIGNIFICANCE Cantilever ceramic RBFDPs in the anterior region are a less invasive and valuable treatment option, providing good esthetic results.
Collapse
Affiliation(s)
- Ahmed Yaseen Alqutaibi
- Substitutive Dental Science Department, College of Dentistry, Taibah University, Al-Madinah, Saudi Arabia
- Department of Prosthodontics, Faculty of Dentistry, Ibb University, Ibb, Yemen
| | | | | | | | | | - Arwa M Mubarak
- College of Dentistry, Taibah University, Al-Madinah, Saudi Arabia
| | | |
Collapse
|
14
|
Thoma DS, Haas R, Sporniak-Tutak K, Garcia A, Taylor TD, Tutak M, Pohl V, Hämmerle CHF. Randomized controlled multi-centre study comparing shorter dental implants (6 mm) to longer dental implants (11-15 mm) in combination with sinus floor elevation procedures: 10-year data. J Clin Periodontol 2024; 51:499-509. [PMID: 38296249 DOI: 10.1111/jcpe.13954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 10/27/2023] [Accepted: 01/12/2024] [Indexed: 03/16/2024]
Abstract
AIM To compare implant survival and complication rates between shorter and standard-length implants with sinus augmentation and restored with single crowns, at 10 years of loading. MATERIALS AND METHODS One-hundred and one patients (137 implants) with a ridge height of 5-7 mm in the posterior maxilla were randomly assigned to two treatment modalities: shorter implants (6 mm) (group short [GS]) or standard-length implants (11-15 mm) with sinus grafting (group graft [GG]). Following the insertion of final restorations, patients were regularly recalled for up to 10 years. Assessed outcomes encompassed implant survival, marginal bone levels (MBLs), biological and technical parameters and patient-reported outcome measures (OHIP-49 = Oral Health Impact Profile). Non-parametric statistical analysis was used to analyse the data. RESULTS For the 5- to 10-year follow-up period, 77 patients with 105 implants (GS: 36 patients/48 implants; GG: 41/57) were available for re-examination (drop-out rate 21%). Implant survival rates at the patient level were 96.0% (GS; 2 failures) and 100% (GG) (inter-group p = .24). Median MBLs amounted to 0.00 mm (min 0.00; max 3.25; GS) and 0.00 mm (min 0.00; max 4.55; GG) (inter-group p = .73). Technical complications predominantly occurred within the first 5 years (inter-group p > .05). Peri-implantitis rates were 4.2% (GS) and 13.3% (GG) (intergroup p = .37). Median OHIP-49 scores were 7.00 (0.00; 39.00; GS) and 9.00 (0.00; 196; GG) (inter-group p = .61) at 10 years. CONCLUSIONS Based on similar 10-year implant survival rates, reduced patient morbidity and lower costs, the use of shorter dental implants might well serve as an alternative treatment concept to longer implants placed in conjunction with sinus grafting for patients with a limited ridge height in the posterior maxilla. Study register: https://clinicaltrials.gov/ct2/show/NCT01030523.
Collapse
Affiliation(s)
- Daniel S Thoma
- Clinic of Reconstructive Dentistry Center of Dental Medicine, University of Zurich, Zürich, Switzerland
| | - Robert Haas
- Akademie für Orale Implantologie, Private Practice, Vienna, Austria
| | | | - Abel Garcia
- University of Santiago de Compostela, Santiago de Compostela, Spain
| | | | - Marcin Tutak
- Aesthetic Dent, Private Practice, Szczecin, Poland
| | - Veronika Pohl
- Akademie für Orale Implantologie, Private Practice, Vienna, Austria
| | - Christoph H F Hämmerle
- Clinic of Reconstructive Dentistry Center of Dental Medicine, University of Zurich, Zürich, Switzerland
| |
Collapse
|
15
|
Yum H, Han HS, Kim K, Kim S, Cho YD. The cumulative survival rate of sandblasted, large-grit, acid-etched dental implants: a retrospective analysis. J Periodontal Implant Sci 2024; 54:122-135. [PMID: 37524380 PMCID: PMC11065536 DOI: 10.5051/jpis.2301440072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 04/26/2023] [Accepted: 05/11/2023] [Indexed: 08/02/2023] Open
Abstract
PURPOSE This retrospective study aimed to assess the long-term cumulative survival rate of titanium, sandblasted, large-grit, acid-etched implants over a 10-year follow-up period and investigate the factors affecting the survival rate and change in marginal bone loss (MBL). METHODS The study included 400 patients who underwent dental implant placement at the Department of Periodontology of Seoul National University Dental Hospital (SNUDH) between 2005 and 2015. Panoramic radiographic images and dental records of patients were collected and examined using Kaplan-Meier analysis, Cox proportional hazards regression analysis, and multiple regression analysis to determine the survival rates and identify any factors related to implant failure and MBL. RESULTS A total of 782 implants were placed with a follow-up period ranging from 0 to 16 years (mean: 8.21±3.75 years). Overall, 25 implants were lost, resulting in a cumulative survival rate of 96.8%. Comparisons of the research variables regarding cumulative survival rate mostly yielded insignificant results. The mean mesial and distal MBLs were 1.85±2.31 mm and 1.59±2.03 mm, respectively. Factors influencing these values included age, diabetes mellitus (DM), jaw location, implant diameter, bone augmentation surgery, and prosthetic unit. CONCLUSIONS This study found that the implant survival rates at SNUDH fell within the acceptable published criteria. The patients' sex, age, DM status, implant location, implant design, implant size, surgical type, bone augmentation, and prosthetic unit had no discernible influence on long-term implant survival. Sandblasted, large-grit, acid-etched implants might offer advantages in terms of implant longevity and consistent clinical outcomes.
Collapse
Affiliation(s)
- Haeji Yum
- Department of Periodontology, School of Dentistry and Dental Research Institute, Seoul National University and Seoul National University Dental Hospital, Seoul, Korea
| | - Hee-Seung Han
- Department of Periodontology, School of Dentistry and Dental Research Institute, Seoul National University and Seoul National University Dental Hospital, Seoul, Korea
| | - Kitae Kim
- Department of Molecular Genetics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Korea
| | - Sungtae Kim
- Department of Periodontology, School of Dentistry and Dental Research Institute, Seoul National University and Seoul National University Dental Hospital, Seoul, Korea
| | - Young-Dan Cho
- Department of Periodontology, School of Dentistry and Dental Research Institute, Seoul National University and Seoul National University Dental Hospital, Seoul, Korea.
| |
Collapse
|
16
|
Tabarak N, Srivastava G, Padhiary SK, Panda S, Das AC, Mohapatra A. Assessment of reproducibility and influence of different dental specialties on functional implant prosthodontic score: A prospective clinical study analyzing single-unit implant crowns. J Indian Prosthodont Soc 2024; 24:122-127. [PMID: 38650336 PMCID: PMC11129812 DOI: 10.4103/jips.jips_441_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 01/05/2024] [Accepted: 01/10/2024] [Indexed: 04/25/2024] Open
Abstract
AIM Implant therapy in partially edentulous patients has become the most adapted and predictable treatment modality. The success rate of implants has been measured in terms of esthetic, biological, and technical factors such as radiographic bone loss, prosthetic complications, and stability. Despite the existence of several indices for the esthetic assessment of implant crowns, a need for functional evaluation of the implant crown with an objective and reproducible score has arisen. The study aims to validate the reproducibility of the functional implant prosthodontic score (FIPS) and the influence exerted by different dental specialties while evaluating posterior single-unit implant crowns. STUDY SETTING AND DESIGN This was a prospective clinical study. MATERIALS AND METHODS Fifteen patients with cement-retained single-implant crowns in the posterior region of the jaws were included. Eight examiners, two prosthodontists, two periodontists, two oral surgeons, and two orthodontists evaluated 15 photographs of single-unit implant crowns during the 1-year follow-up examination. The examiners assessed the photographs for FIPS, which includes five parameters for objectively evaluating the single-unit implant crowns. Assessments were performed twice at a gap of 4 weeks. STATISTICAL ANALYSIS USED Pearson's correlation with a 95% confidence interval was calculated for the intra-examiner and the Kruskal-Wallis test for inter-examiner reproducibility. RESULTS The mean total FIPS scores for all included examiners were 7.133 for time T1 and 7.074 for time T2, showing a strong Pearson correlation coefficient for intra-examiner reproducibility. No significant difference was analyzed among different specialties with statistically significant values of the Kruskal-Wallis test. CONCLUSION Intra- and inter-examiner analysis showed very consistent results during the reproducibility assessment of FIPS. The results validated the use of FIPS as a long-term predictive functional evaluation tool for the single-implant crowns in posterior sites irrespective of the effect of different dental specialties. It could be used for risk estimation and prognosis for long-term survival and performance of implant crowns.
Collapse
Affiliation(s)
- Naghma Tabarak
- Department of Prosthodontics, Institute of Dental Sciences, Siksha 'O' Anusandhan Deemed to be University, Bhubaneswar, Odisha, India
| | - Gunjan Srivastava
- Department of Prosthodontics, Institute of Dental Sciences, Siksha 'O' Anusandhan Deemed to be University, Bhubaneswar, Odisha, India
| | - Subrat Kumar Padhiary
- Department of Oral and Maxillofacial Surgery, Institute of Dental Sciences, Siksha 'O' Anusandhan Deemed to be University, Bhubaneswar, Odisha, India
| | - Swagatika Panda
- Department of Oral and Maxillofacial Pathology, Institute of Dental Sciences, Siksha 'O' Anusandhan Deemed to be University, Bhubaneswar, Odisha, India
| | - Abhaya Chandra Das
- Department of Periodontics, Institute of Dental Sciences, Siksha 'O' Anusandhan Deemed to be University, Bhubaneswar, Odisha, India
| | - Abhilash Mohapatra
- Department of Prosthodontics, Institute of Dental Sciences, Siksha 'O' Anusandhan Deemed to be University, Bhubaneswar, Odisha, India
| |
Collapse
|
17
|
Goldstein G, Goodacre C, Brown MS, Tarnow DP. Proposal regarding potential causes related to certain complications with dental implants and adjacent natural teeth: Physics applied to prosthodontics. J Prosthodont 2024. [PMID: 38512996 DOI: 10.1111/jopr.13843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Accepted: 03/03/2024] [Indexed: 03/23/2024] Open
Abstract
PURPOSE Complications can and do occur with implants and their restorations with causes having been proposed for some single implant complications but not for others. METHODS A review of pertinent literature was conducted. A PubMed search of vibration, movement, and dentistry had 175 citations, while stress waves, movement, and dentistry had zero citations as did stress waves, movement. This paper discusses the physics of vibration, elastic and inelastic collision, and stress waves as potentially causative factors related to clinical complications. RESULTS Multiple potential causes for interproximal contact loss have been presented, but it has not been fully understood. Likewise, theories have been suggested regarding the intrusion of natural teeth when they are connected to an implant as part of a fixed partial denture as well as intrusion when a tooth is located between adjacent implants, but the process of intrusion, and resultant extrusion, is not fully understood. A third complication with single implants and their crowns is abutment screw loosening with several of the clinical characteristics having been discussed but without determining the underlying process(es). CONCLUSIONS Interproximal contact loss, natural tooth intrusion, and abutment screw loosening are common complications that occur with implant retained restorations. Occlusion is a significant confounding variable. The hypothesis is that vibration, or possibly stress waves, generated from occlusal impact forces on implant crowns and transmitted to adjacent teeth, are the causative factors in these events. Since occlusion appears to play a role in these complications, it is recommended that occlusal contacts provide centralized stability on implant crowns and not be located on any inclined surfaces that transmit lateral forces that could be transmitted to an adjacent tooth and cause interproximal contact loss or intrusion. The intensity, form, and location of proximal contacts between a natural tooth located between adjacent single implant crowns seem to play a role in the intrusion of the natural tooth. Currently, there is a lack of information about the underlying mechanisms related to these occurrences and research is needed to define any confounding variables.
Collapse
Affiliation(s)
- Gary Goldstein
- Department of Prosthodontics, New York University College of Dentistry, New York, New York, USA
| | - Charles Goodacre
- Advanced Education Program in Implant Dentistry, Loma Linda University School of Dentistry, Loma Linda, California, USA
| | | | - Dennis P Tarnow
- Columbia University College of Dental Medicine, New York, New York, USA
| |
Collapse
|
18
|
Herrera-Pérez P, García-De-La-Fuente AM, Andia-Larrea E, Marichalar-Mendia X, Aguirre-Urizar JM, Aguirre-Zorzano LA. Clinical analysis of the tooth-implant papilla for two narrow-diameter titanium-zirconium implants in the anterior area: prospective controlled clinical study. BMC Oral Health 2024; 24:310. [PMID: 38443879 PMCID: PMC10916199 DOI: 10.1186/s12903-024-04075-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2023] [Accepted: 02/26/2024] [Indexed: 03/07/2024] Open
Abstract
BACKGROUND Rehabilitation of the anterior area when the mesio-distal space is reduced is a challenge for the clinician, due to the patient's anatomical limitations and aesthetic requirements. Narrow Diameter Implants (NDI) are an option of treatment when the standard diameter implant is not possible, but the evidence is scarce. This prospective clinical study aims to analyze the formation of the tooth-implant papilla between the implant and the adjacent natural tooth in the maxillary lateral incisors and mandibular incisors. METHODS A total of 40 patients treated with NDI, of titanium-zirconium (Ti-Zr) alloy i.e., 2.9 mm Test Group (TG) and 3.3 mm Control Group (CG), were included. The mesiodistal distance between the adjacent natural teeth was used for implant selection, maintaining 1.5 mm between the fixation and the adjacent tooth. Clinical assessment was performed by a clinical examiner at 6 and 12 months after the final prosthesis. The primary variable was the Jemt Papillary Index. Also, implant survival rate (SR), complications, Implant Stability Quotient (ISQ), and patient-reported outcomes measures (PROMs) such as aesthetics, chewing, phonation, comfort, and self-esteem were analyzed. RESULTS A significant amount of papilla filling was observed concerning the baseline, with a trend towards more formation of the papilla in the TG, with a JPI score of 3. No significant differences were observed between the two groups regarding implant SR, clinical parameters, and complications. In terms of PROMs, a higher satisfaction in the TG was observed, with significant intergroup differences for aesthetics, comfort, self-esteem, and primary stability ISQ (TG: 59.05 (SD: 5.4) vs. CG: 51.55 (SD: 5.7)). CONCLUSIONS The 2.9 mm diameter Ti-Zr implants achieved a formation of papilla similar to 3.3 mm implants in the anterior region at 12 months of follow-up after the final prosthetic restoration. The use of Ti-Zr implants with a diameter of 2.9 mm to rehabilitate single teeth in areas of the anterior region, where the mesiodistal distance is limited, showed favorable clinical results and a high degree of satisfaction during 1 year of observation similar to 3.3 mm dental implants. TRIAL REGISTRATION This study was retrospectively registered in ClinicalTrials.gov with the number NCT05642520, dated 18/11/2022.
Collapse
Affiliation(s)
| | - Ana María García-De-La-Fuente
- Research Group: GIU21/042Department of StomatologyFaculty of Medicine and Nursing, University of the Basque Country (UPV/EHU), Barrio Sarriena S/N, 48940, Leioa, Biscay, Spain.
| | - Eztizen Andia-Larrea
- International University of Catalunya, Barcelona, Spain
- Department of Stomatology, University of the Basque Country (UPV/EHU), Biscay, Spain
| | - Xabier Marichalar-Mendia
- Research Group: GIU21/042, Department of Nursery I, University of the Basque Country (UPV/EHU), Biscay, Spain
| | - José Manuel Aguirre-Urizar
- Research Group: GIU21/042Department of StomatologyFaculty of Medicine and Nursing, University of the Basque Country (UPV/EHU), Barrio Sarriena S/N, 48940, Leioa, Biscay, Spain
| | - Luis Antonio Aguirre-Zorzano
- Research Group: GIU21/042Department of StomatologyFaculty of Medicine and Nursing, University of the Basque Country (UPV/EHU), Barrio Sarriena S/N, 48940, Leioa, Biscay, Spain
| |
Collapse
|
19
|
de Holanda Cavalcanti Pereira AK, de Oliveira Limirio JPJ, Cavalcanti do Egito Vasconcelos B, Pellizzer EP, Dantas de Moraes SL. Mechanical behavior of titanium and zirconia abutments at the implant-abutment interface: A systematic review. J Prosthet Dent 2024; 131:420-426. [PMID: 35292155 DOI: 10.1016/j.prosdent.2022.01.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2021] [Revised: 01/06/2022] [Accepted: 01/07/2022] [Indexed: 10/18/2022]
Abstract
STATEMENT OF PROBLEM Zirconia has become popular for dental implant abutments in the esthetic zone but can damage the implant connection interface. Studies have been conducted to compare zirconia abutments with conventional titanium abutments; however, a consensus or systematic review is lacking. PURPOSE The purpose of this systematic review was to evaluate the performance of abutments made of zirconia and titanium in relation to wear and misfit at the implant-abutment interface. MATERIAL AND METHODS Electronic databases (PubMed/MEDLINE, Embase, Web of Science) were independently searched by 2 researchers for relevant studies published up to June 2021. The population, intervention, comparison, outcome (PICO) question was "Do zirconia abutments cause greater wear at the implant-abutment interface than titanium abutments under occlusal forces?" Eligible studies included in vitro studies that evaluated changes in the surface of external and/or internal connections and single and/or multiple, screwed and/or cemented prostheses rehabilitated with titanium and zirconia abutments submitted to mechanical cycling. RESULTS Nine studies were included for qualitative analysis. A total of 172 specimens were analyzed, 86 zirconia and 86 titanium abutments. In terms of wear on the implant connection surface, zirconia abutments caused more severe wear, more scratches, and more rounding of the hexagonal angles at the implant connection interface than titanium abutments. In terms of misfit at the connection interface, zirconia abutments showed greater misfit than titanium abutments. CONCLUSIONS Zirconia abutments produce more wear at the titanium implant connection interface, titanium abutments showed better fit to the implant connection interface, and the fit can be influenced by the abutment manufacturing method.
Collapse
Affiliation(s)
| | | | | | - Eduardo Piza Pellizzer
- Full Professor, Department of Dental Materials and Prosthodontics, Sao Paulo State University (UNESP), Araçatuba, São Paulo, Brazil.
| | - Sandra Lúcia Dantas de Moraes
- Associate Professor, Division of Oral Rehabilitation, Faculty of Dentistry, University of Pernambuco (UFPE), Recife, Pernambuco, Brazil
| |
Collapse
|
20
|
Alhomsi A, Aldoss H, Aljoujou AA, Mashlah AM, Hajeer MY, Alyafi A, Almasri IA. Exploring How People Interact With Dental Misinformation on Social Media: A Cross-Sectional Study. Cureus 2024; 16:e56625. [PMID: 38516284 PMCID: PMC10956376 DOI: 10.7759/cureus.56625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/21/2024] [Indexed: 03/23/2024] Open
Abstract
BACKGROUND Social media has been widely utilized to spread health-related information, which has led to the possibility of spreading medical misinformation. The extent of the issue is unknown, even though policymakers, researchers, and medical professionals agree that health misinformation must be controlled and combated. OBJECTIVE A cross-sectional study was conducted by the faculty of dentistry at Damascus University. METHODS This quantitative cross-sectional study used a voluntary questionnaire distributed online in social media groups. Participants were of different ages, genders, and educational levels. RESULTS Of the 301 questionnaires collected, 291 were analyzed. The study sample comprised secondary education certificates, university students, and postgraduate students. 96.6% of the study sample used two or more SM applications. 71.5% of the study sample uses Facebook more than other applications for dental information research, followed by Instagram (14.8%), Telegram (8.2%), and finally WhatsApp (5.5%). There was a significant difference between the age of the respondents and the SM application they used most (p = 0.027). 46.4% of the study sample were neutral in their answer about what they believed in the trust of information on SM sites, followed by 42.3% who did not agree with the trust of information on SM sites and 11.3 who agreed. 89.7% of the study sample visit the dentist when facing a medical problem, while 10.3% follow advice on SM sites. There was a significant difference between the age of respondents and the source they relied on when facing a medical problem (p = 0.019). 50.2% of the study sample sometimes feels that the advice on SM sites is marketing for a company or product or advertising for doctors and not others. CONCLUSION In particular, understanding the methods and prevalence of health misinformation, as well as the current gaps in knowledge in this area, will help us to guide future research and, more specifically, to develop evidence-based digital policy action plans targeted at addressing this public health issue through various social media platforms.
Collapse
Affiliation(s)
- Alaa Alhomsi
- Department of Oral Medicine, Faculty of Dentistry, University of Damascus, Damascus, SYR
| | - Hala Aldoss
- Department of Oral Medicine, Faculty of Dentistry, University of Damascus, Damascus, SYR
| | - Abeer A Aljoujou
- Department of Oral Medicine, Faculty of Dentistry, University of Damascus, Damascus, SYR
| | - Ammar Mahmoud Mashlah
- Department of Oral Medicine, Faculty of Dentistry, University of Damascus, Damascus, SYR
| | - Mohammad Y Hajeer
- Department of Orthodontics, Faculty of Dentistry, University of Damascus, Damascus, SYR
| | - Amr Alyafi
- Department of Oral Medicine, Faculty of Dentistry, University of Damascus, Damascus, SYR
| | - Imad Addin Almasri
- Department of Applied Statistics, Faculty of Economics, University of Damascus, Damascus, SYR
| |
Collapse
|
21
|
Tekpınar L, Yiğit V. Cost-Effectiveness Analysis of Implant-Supported Single Crown and Tooth-Supported Fixed Dental Prostheses in Türkiye. Value Health Reg Issues 2024; 42:11-17. [PMID: 38340673 DOI: 10.1016/j.vhri.2024.01.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2023] [Revised: 12/19/2023] [Accepted: 01/08/2024] [Indexed: 02/12/2024]
Abstract
OBJECTIVES The most cost-effective option for replacing lost teeth is not evident because there is a dearth of evidence-based information on implant-supported single crowns versus tooth-supported fixed dental prostheses. This study conducted the analysis of cost-effectiveness of implant-supported single crown and tooth-supported fixed dental prostheses from a social perspective in Türkiye. METHODS Costs were calculated in the analysis from a social perspective for 2021. Costs and quality-adjusted prosthesis year (QAPY) values were computed over a 20-year period in the study using the Markov model. The computed values were discounted by 5%. The results are presented as the incremental cost-effectiveness ratio. To assess the impact of uncertainty on cost-effectiveness analyses, a tornado diagram and Monte Carlo simulations were created. RESULTS Throughout the 20-year time horizon, tooth-supported fixed dental prostheses cost $985.58 cumulatively, whereas implant-supported single crown cost $2161.64 (US $1 = 9.22 ₺ as of 15 October 2021). The calculated incremental cost-effectiveness ratio is 1.333 per QAPY. Compared with the implant-supported single crown tooth-supported fixed dental prostheses, it offers a QAPY of 0.882 over a 20-year period, while costing an additional $1176.06. CONCLUSIONS These results suggest that the implant-supported single crown provided higher QAPY value but was costlier. When the research's findings are compared with the literature, it becomes clear that Türkiye has lower dental care expenses than most other nations.
Collapse
Affiliation(s)
- Lütfiye Tekpınar
- Department of Health Economics, Nezahat Keleşoğlu Faculty of Health Sciences, Necmettin Erbakan University, Konya, Türkiye; Department of Health Management, Nezahat Keleşoğlu Faculty of Health Sciences, Necmettin Erbakan University, Konya, Türkiye.
| | - Vahit Yiğit
- Department of Hospital Management, Faculty of Economics and Administrative Sciences, Süleyman Demirel University, Isparta, Türkiye; Department of Health Management, Faculty of Economics and Administrative Sciences, Süleyman Demirel University, Isparta, Türkiye
| |
Collapse
|
22
|
Mo JJ, Lai YR, Huang QR, Li YR, Zhang YJ, Chen RY, Qian SJ. Single-cell sequencing identifies inflammation-promoting fibroblast-neutrophil interaction in peri-implantitis. J Clin Periodontol 2024; 51:196-208. [PMID: 38088448 DOI: 10.1111/jcpe.13912] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2023] [Revised: 10/17/2023] [Accepted: 11/16/2023] [Indexed: 01/19/2024]
Abstract
AIM To reveal the cellular composition and molecular environment of the periodontal and peri-implant inflammatory infiltrates through a single-cell sequencing technique, which may explain the pathological difference between these two diseases. A special focus was placed on the phenotypes and potential roles of neutrophils and fibroblasts in peri-implant/periodontal tissue immunity. MATERIALS AND METHODS High-throughput single-cell transcriptomic profiling of peri-implant tissues from patients with peri-implantitis as well as periodontal tissues from patients with periodontitis and healthy donors was performed. Immunofluorescence analysis was carried out to further validate the identified cell subtypes and their involvement in peri-implantitis and periodontitis. RESULTS Based on our single-cell resolution analysis, a quantified proportional increase of neutrophil (Neu) subtypes was shown in peri-implantitis. Among these, a predominance of Neutro_CXCR2 was revealed. We also found the involvement of inflammation-promoting fibroblasts as well as a predominance of CXCL8+ fibroblast-CXCR2+ neutrophil interaction in peri-implantitis. CONCLUSIONS Our study indicated that the predominance of CXCL8+ fibroblast-CXCR2+ neutrophil interaction might underline the enhanced host response in peri-implantitis compared with periodontitis. This information offers a molecular basis by which fibroblast and neutrophil subtypes might be diagnostically and therapeutically targeted in peri-implantitis.
Collapse
Affiliation(s)
- Jia-Ji Mo
- Department of Implant Dentistry, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, Shanghai, China
- National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai, China
| | - Yi-Rao Lai
- Department of Implant Dentistry, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, Shanghai, China
- National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai, China
| | - Qian-Ru Huang
- Department of Immunology and Microbiology, Shanghai Institute of Immunology, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Yin-Ran Li
- Department of Implant Dentistry, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, Shanghai, China
- National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai, China
| | - Yi-Jie Zhang
- Department of Implant Dentistry, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, Shanghai, China
- National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai, China
| | - Rui-Ying Chen
- Department of Implant Dentistry, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, Shanghai, China
- National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai, China
| | - Shu-Jiao Qian
- Department of Implant Dentistry, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, Shanghai, China
- National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai, China
| |
Collapse
|
23
|
Amid R, Moscowchi A, Azizi S, Hosseini M, Hartoonian S. Coverage stability of peri-implant soft tissue dehiscence: A systematic review and meta-analysis. J ESTHET RESTOR DENT 2024; 36:284-294. [PMID: 37494605 DOI: 10.1111/jerd.13113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 07/09/2023] [Accepted: 07/14/2023] [Indexed: 07/28/2023]
Abstract
OBJECTIVE The occurrence of peri-implant soft tissue dehiscence, especially in the esthetic zone, can be challenging. This study sought to investigate how the passage of time affects the outcomes of treatment for peri-implant soft tissue dehiscence coverage. MATERIALS AND METHODS A literature search was performed up to April 2023 via PubMed, Scopus, and Web of Science to retrieve studies reporting the data on peri-implant soft tissue dehiscence of at least 2-time points (baseline and follow-up). Clinical trials with a minimum of 5 participants, reporting at least 1 primary outcome, and with a minimum follow-up of 3 months were included. The primary outcomes were the changes in dehiscence depth, complete coverage, and mean coverage at different time points. RESULTS Seven studies with 112 participants and 119 implants were included. Dehiscence depth increased insignificantly between 3 to 6 months. Although the dehiscence depth increased from 6 to 12 months in the tunnel group, it decreased in the coronally advanced group, and a slight decrease was observed from 12 to 72 months. Soft tissue thickness was the predictor for soft tissue margin stability. However, no significant relationship was found between the baseline dehiscence depth and complete coverage. CONCLUSIONS Within the limitations of this study, it seems prudent to wait at least 6 months to achieve a stable soft tissue margin. CLINICAL SIGNIFICANCE The occurrence of peri-implant soft tissue dehiscence, especially in the esthetic zone, can be a challenging complication. It is important not only to achieve coverage but also to ensure that the treatment results remain stable in the long term, in order to satisfy both patients and clinicians. A reasonable approach would be to wait for at least 6 months to achieve a stable soft tissue margin.
Collapse
Affiliation(s)
- Reza Amid
- Research Institute for Dental Sciences, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
- Department of Periodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Anahita Moscowchi
- Research Institute for Dental Sciences, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
- Department of Periodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Soroush Azizi
- Research Institute for Dental Sciences, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
- Department of Periodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Matineh Hosseini
- Research Institute for Dental Sciences, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
- Department of Periodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Serlie Hartoonian
- Research Institute for Dental Sciences, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
- Department of Periodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
24
|
da Rosa LS, Soares PM, Packaeser MG, Chiapinotto GF, Bacchi A, Tribst JPM, Kleverlaan CJ, Pereira GKR. Effect of abutment screw-access hole on the fatigue performance of implant-supported lithium-disilicate luted simplified restorations. J Mech Behav Biomed Mater 2024; 150:106254. [PMID: 38035645 DOI: 10.1016/j.jmbbm.2023.106254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Revised: 11/13/2023] [Accepted: 11/15/2023] [Indexed: 12/02/2023]
Abstract
The present study aimed to evaluate the impact of the existence of an abutment screw-access hole and the filling effects on the fatigue mechanical behavior of a luted lithium-disilicate glass-ceramic. Seventy-two discs (Ø = 10 mm, 1.0 mm in thickness) of lithium disilicate (IPS e.max CAD, Ivoclar AG) were obtained from prefabricated blocks. Thirty-six abutment specimens of an opaque zirconia (Yz - IPS e.max ZirCAD, Ivoclar AG) and titanium (Ti - Luminesse Ti-Cam discs, Talladium Inc.) were confectioned, and allocated according to 6 groups: Yz and Ti rigid (without screw access hole); Yz unfilled, Yz filled, Ti unfilled and Ti filled (with the screw access (Ø = 2.5 mm) in the center). For the unfilled groups, only a polytetrafluoroethylene tape was used. Resin composite (Tetric N-Ceram, Ivoclar AG) was applied to the screw access hole for the filled groups (Yz and Ti). A cyclic fatigue test was carried out (load of 200 N, 10,000 cycles each; 20 Hz of frequency, step size of 100 N until failure detection (radial/cone crack). The fatigue failure load (FFL) and number of cycles until failure (CFF) were recorded for statistical purposes. The stress distribution (MPa) was evaluated by finite element analysis. A statistically positive effect of the abutment material and the presence of the screw access hole was observed (p ≤ 0.05). The rigid groups (without screw access holes) depicted almost 100% of survival after the fatigue tests. Among the other groups, the Yz-filled group showed the best performance (p ≤ 0.05), followed by the Yz unfilled group. The Ti groups depicted lower values of FFL and CFF, with the Ti unfilled group showing the most unfavorable fatigue behavior (p ≤ 0.05). The lowest tensile stress concentration in the restorative material was observed with the use of rigid abutments, the filled groups depicted intermediate values, while unfilled groups showed the highest stress concentration (Yz rigid = 306.3 MPa; Ti rigid = 310.4 MPa < Yz filled = 490.7 MPa; Ti filled = 498.9 MPa < Yz unfilled = 707.6 MPa; Ti unfilled = 719.7 MPa). Therefore, the presence of a screw-access hole decreases the mechanical performance of a lithium disilicate ceramic regardless of the abutment material. In the presence of a screw-access hole, zirconia abutments depicted a higher fatigue failure load when compared with titanium. The filling of the abutment screw-access hole with resin composite increased the mechanical performance of the simulated restoration.
Collapse
Affiliation(s)
- Lucas Saldanha da Rosa
- Post-Graduate Program in Oral Sciences (Prosthodontics Unit), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Pablo Machado Soares
- Post-Graduate Program in Oral Sciences (Prosthodontics Unit), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Maria Gabriela Packaeser
- Post-Graduate Program in Oral Sciences (Prosthodontics Unit), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Gratcheva Falcão Chiapinotto
- Post-Graduate Program in Oral Sciences (Prosthodontics Unit), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Atais Bacchi
- Post-Graduate Program in Dentistry, Paulo Picanço School of Dentistry (FACPP), Fortaleza, Ceará State, Brazil.
| | - João Paulo Mendes Tribst
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, North Holland, the Netherlands.
| | - Cornelis Johannes Kleverlaan
- Department of Dental Materials, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, North Holland, the Netherlands.
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Sciences (Prosthodontics Unit), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
25
|
Nam DH, Kim PJ, Koo KT, Seol YJ, Lee YM, Ku Y, Rhyu IC, Kim S, Cho YD. The cumulative survival rate of dental implants with micro-threads: a long-term retrospective study. J Periodontal Implant Sci 2024; 54:53-62. [PMID: 37336523 PMCID: PMC10901680 DOI: 10.5051/jpis.2203240162] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Revised: 11/03/2022] [Accepted: 11/29/2022] [Indexed: 06/21/2023] Open
Abstract
PURPOSE This study aimed to evaluate the long-term cumulative survival rate (CSR) of dental implants with micro-threads in the neck over a 10-year follow-up period and to examine the factors influencing the survival rate of dental implants. METHODS This retrospective study was based on radiographic and dental records. In total, 151 patients received 490 Oneplant® dental implants with an implant neck micro-thread design during 2006-2010 in the Department of Periodontology of Seoul National University Dental Hospital. Implant survival was evaluated using Kaplan-Meier analysis. Cox proportional hazard regression analysis was used to identify the factors influencing implant failure. RESULTS Ten out of 490 implants (2.04%) failed due to fixture fracture. The CSR of the implants was 97.9%, and no significant difference was observed in the CSR between external- and internal-implant types (98.2% and 97.6%, respectively, P=0.670). In Cox regression analysis, 2-stage surgery significantly increased the risk of implant failure (hazard ratio: 4.769, P=0.039). There were no significant differences in influencing factors, including sex, age, implant diameter, length, fixture type, location, surgical procedure, bone grafting, and restoration type. CONCLUSIONS Within the limitations of this retrospective study, the micro-thread design of the implant neck was found to be favorable for implant survival, with stable clinical outcomes.
Collapse
Affiliation(s)
- Dong-Hui Nam
- Department of Periodontology, School of Dentistry and Dental Research Institute, Seoul National University and Seoul National University Dental Hospital, Seoul, Korea
| | - Pil-Jong Kim
- Biomedical Knowledge Engineering Laboratory, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Korea
| | - Ki-Tae Koo
- Department of Periodontology, School of Dentistry and Dental Research Institute, Seoul National University and Seoul National University Dental Hospital, Seoul, Korea
| | - Yang-Jo Seol
- Department of Periodontology, School of Dentistry and Dental Research Institute, Seoul National University and Seoul National University Dental Hospital, Seoul, Korea
| | - Yong-Moo Lee
- Department of Periodontology, School of Dentistry and Dental Research Institute, Seoul National University and Seoul National University Dental Hospital, Seoul, Korea
| | - Young Ku
- Department of Periodontology, School of Dentistry and Dental Research Institute, Seoul National University and Seoul National University Dental Hospital, Seoul, Korea
| | - In-Chul Rhyu
- Department of Periodontology, School of Dentistry and Dental Research Institute, Seoul National University and Seoul National University Dental Hospital, Seoul, Korea
| | - Sungtae Kim
- Department of Periodontology, School of Dentistry and Dental Research Institute, Seoul National University and Seoul National University Dental Hospital, Seoul, Korea.
| | - Young-Dan Cho
- Department of Periodontology, School of Dentistry and Dental Research Institute, Seoul National University and Seoul National University Dental Hospital, Seoul, Korea.
| |
Collapse
|
26
|
Tajti P, Solyom E, Váncsa S, Mátrai P, Hegyi P, Varga G, Hermann P, Borbély J, Sculean A, Mikulás K. Less marginal bone loss around bone-level implants restored with long abutments: A systematic review and meta-analysis. Periodontol 2000 2024; 94:627-638. [PMID: 37766634 DOI: 10.1111/prd.12534] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 09/12/2023] [Accepted: 09/15/2023] [Indexed: 09/29/2023]
Abstract
The aim of this study was to investigate the biological outcomes of bone-level implants restored with long vs. short abutments, with regard to the 'one abutment at one time' protocol. The systematic search was performed in five databases: MEDLINE (PubMed), EMBASE, Web of Science, Scopus, and CENTRAL for randomized controlled trials up to January 14, 2023. Data were collected for marginal bone loss, bleeding on probing, and probing pocket depth by two reviewers. As effect size measure, mean difference (MD), and risk ratio (RR) were used for continuous and categorical outcomes, R-statistics software was used for conducting statistical analyses. For quality and certainty assessment, Risk of Bias Tool 2, ROBINS-I, and GRADE approach were used. The search resulted in 4055 records without any duplicates. After title, abstract, and full-text analysis, eight articles were found eligible for inclusion. Bone-level and platform-switched implants presented less marginal bone loss after 6 months and 1 year as well, when long abutments were used (MD 0.63, 95% CI: [-0.16; 1.42]) and (MD 0.26, 95% CI: [-0.02; 0.53]). However, subgroup analysis revealed no difference in marginal bone loss when applying 'one abutment at one time' protocol (p = 0.973). Bleeding on probing and probing pocket depth presented similarly good results in both groups without almost any differences (RR 0.97, 95% CI: [0.76; 1.23]) and (MD -0.05, 95% CI: [-1.11; 1.01]). Longer abutments on bone-level implants seem to be a favorable choice for decreasing early marginal bone loss, irrespective of connection timing.
Collapse
Affiliation(s)
- Péter Tajti
- Department of Prosthodontics, Semmelweis University, Budapest, Hungary
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Eleonora Solyom
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
- Department of Periodontology, Semmelweis University, Budapest, Hungary
| | - Szilárd Váncsa
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Péter Mátrai
- Institute for Translational Medicine, Medical School, University of Pécs, Pécs, Hungary
| | - Péter Hegyi
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
- Institute for Translational Medicine, Medical School, University of Pécs, Pécs, Hungary
- Institute of Pancreatic Diseases, Semmelweis University, Budapest, Hungary
| | - Gábor Varga
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
- Department of Oral Biology, Semmelweis University, Budapest, Hungary
| | - Péter Hermann
- Department of Prosthodontics, Semmelweis University, Budapest, Hungary
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Judit Borbély
- Department of Prosthodontics, Semmelweis University, Budapest, Hungary
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Anton Sculean
- Department of Periodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Krisztina Mikulás
- Department of Prosthodontics, Semmelweis University, Budapest, Hungary
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| |
Collapse
|
27
|
Song L, Feng Z, Zhou Q, Wu X, Zhang L, Sun Y, Li R, Chen H, Yang F, Yu Y. Metagenomic analysis of healthy and diseased peri-implant microbiome under different periodontal conditions: a cross-sectional study. BMC Oral Health 2024; 24:105. [PMID: 38233815 PMCID: PMC10795403 DOI: 10.1186/s12903-023-03442-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2023] [Accepted: 09/21/2023] [Indexed: 01/19/2024] Open
Abstract
BACKGROUND Peri-implantitis is a polybacterial infection that can lead to the failure of dental implant rehabilitation. This study aimed to profile the microbiome of the peri-implant plaque and estimate the effect of periodontitis on it among 40 Chinese participants with dental implant prostheses and presenting with varying peri-implant and periodontal health states. METHODS Submucosal plaque samples were collected from four distinct clinical categories based on both their implant and periodontal health status at sampling point. Clinical examinations of dental implant and remaining teeth were carried out. Metagenomic analysis was then performed. RESULTS The microbiome of the peri-implantitis sites differed from that of healthy implant sites, both taxonomically and functionally. Moreover, the predominant species in peri-implantitis sites were slightly affected by the presence of periodontitis. T. forsythia, P. gingivalis, T. denticola, and P. endodontalis were consistently associated with peri-implantitis and inflammatory clinical parameters regardless of the presence of periodontitis. Prevotella spp. and P. endodontalis showed significant differences in the peri-implantitis cohorts under different periodontal conditions. The most distinguishing function between diseased and healthy implants is related to flagellar assembly, which plays an important role in epithelial cell invasion. CONCLUSIONS The composition of the peri-implant microbiome varied in the diseased and healthy states of implants and is affected by individual periodontal conditions. Based on their correlations with clinical parameters, certain species are associated with disease and healthy implants. Flagellar assembly may play a vital role in the process of peri-implantitis.
Collapse
Affiliation(s)
- Liang Song
- Department of Stomatology, Shanghai Fifth People's Hospital, Fudan University, 801 Heqing Road, Shanghai, 200240, China
| | - Ziying Feng
- Department of Stomatology, Shanghai Fifth People's Hospital, Fudan University, 801 Heqing Road, Shanghai, 200240, China
| | - Qianrong Zhou
- Department of Stomatology, Zhongshan Hospital of Fudan University, 180 Fenglin Road, Shanghai, 200032, China
| | - Xingwen Wu
- Department of Stomatology, Zhongshan Hospital of Fudan University, 180 Fenglin Road, Shanghai, 200032, China
| | - Limin Zhang
- Department of Stomatology, Shanghai Fifth People's Hospital, Fudan University, 801 Heqing Road, Shanghai, 200240, China
| | - Yang Sun
- Department of Stomatology, Zhongshan Hospital of Fudan University, 180 Fenglin Road, Shanghai, 200032, China
| | - Ruixue Li
- Department of Stomatology, Zhongshan Hospital of Fudan University, 180 Fenglin Road, Shanghai, 200032, China
| | - Huijuan Chen
- Department of Stomatology, Shanghai Fifth People's Hospital, Fudan University, 801 Heqing Road, Shanghai, 200240, China
| | - Fei Yang
- Department of Stomatology, Zhongshan Hospital of Fudan University, 180 Fenglin Road, Shanghai, 200032, China.
| | - Youcheng Yu
- Department of Stomatology, Zhongshan Hospital of Fudan University, 180 Fenglin Road, Shanghai, 200032, China.
| |
Collapse
|
28
|
Viski IS, Lee JD, Scialabba R, Lee SJ. Retrieval of cement-retained zirconia implant-supported crowns with an Er,Cr:YSGG laser. J Prosthet Dent 2024:S0022-3913(23)00830-2. [PMID: 38184397 DOI: 10.1016/j.prosdent.2023.12.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 12/14/2023] [Accepted: 12/15/2023] [Indexed: 01/08/2024]
Abstract
STATEMENT OF PROBLEM Cement-retained implant-supported crowns can be challenging to retrieve from the abutment once technical or biological issues arise. Removal traditionally requires sectioning the crown with rotary instruments, which causes irreversible damage to the crown and potential damage to the periodontal apparatus stabilizing the implant. PURPOSE The purpose of this in vitro study was to evaluate an erbium, chromium-doped yttrium, scandium, gallium, and garnet (Er,Cr:YSGG) laser as a minimally invasive alternative for the retrieval of zirconia implant-supported crowns from titanium abutments. Time, temperature, and structural changes to the crown after retrieval were assessed. Appropriate laser parameters were established for this method of crown retrieval. MATERIAL AND METHODS Twenty zirconia crowns were milled for a maxillary left second premolar based on a CAD-CAM implant analog cast. Ten of these crowns were cemented with a noneugenol zinc oxide dental cement (group Temp) (n=10). The remaining 10 were cemented with a self-adhesive universal resin cement (group Resin) (n=10). Er,Cr:YSGG laser irradiation was performed with the Waterlase iPlus for 1-minute cycles. An attempt was made to remove the crown with a mechanical instrument after each cycle. A type K thermocouple continuously recorded temperature at the level of the abutment. For statistical comparison of decementation time and temperature, the Mann-Whitney test was used (α=.05). Scanning electron microscopy of the nonirradiated and the irradiated crowns was used for analysis of structural and dimensional changes. RESULTS A significant difference (P<.001) was found in the time ±standard deviation required to retrieve the crowns between group Temp (02:40 ±00:18 minutes:seconds) and group Resin (05:26 ±00:36 minutes:seconds). A significant difference (P<.001) was found in the mean ±standard deviation temperature recorded between group Temp (24.0 ±1.19 °C) and group Resin (25.7 ±0.66 °C). No structural changes to crowns were observed after irradiation. CONCLUSIONS Retrieval of cement-retained zirconia implant-supported crowns with an Er,Cr:YSGG laser is safe and efficient. Crowns luted with zinc oxide dental cement were retrieved significantly faster while maintaining a significantly lower average temperature than those luted with resin cement. Laser irradiation for decementation did not cause structural changes to zirconia implant-supported crowns.
Collapse
Affiliation(s)
- Ionut Sebastian Viski
- Graduate student, Advanced Graduate Prosthodontics, Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Mass
| | - Jason D Lee
- Assistant professor, Advanced Graduate Prosthodontics, Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Mass
| | - Rebecca Scialabba
- Graduate Dental student, Harvard School of Dental Medicine, Boston, Mass
| | - Sang J Lee
- Associate Professor, Advanced Graduate Prosthodontics, Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Mass.
| |
Collapse
|
29
|
Schubert O, Goob J, Schweiger J, Güth JF, Edelhoff D, Graf T. Clinical performance of monolithic lithium disilicate hybrid abutment crowns over at least 3.5 years. J Prosthodont 2024; 33:34-40. [PMID: 37243453 DOI: 10.1111/jopr.13719] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Accepted: 05/19/2023] [Indexed: 05/28/2023] Open
Abstract
PURPOSE Hybrid abutment crowns (HACs) made from monolithic ceramics represent an efficient option for single restorations on implants. However, long-term data are scarce. The purpose of this clinical trial was to evaluate the survival and complication rates of CAD-CAM fabricated HACs over a time period of at least 3.5 years. MATERIALS AND METHODS Twenty-five patients with a total of 40 HACs made of monolithic lithium disilicate ceramic bonded to a titanium base CAD-CAM abutment were retrospectively evaluated. All implants and screw-retained restorations were placed and manufactured in the same department of a university hospital. Only crowns that had been in service for more than 3.5 years were included in the study. HACs were evaluated regarding technical and biological complications. Functional Implant Prosthodontic Scores (FIPS) were obtained. RESULTS The mean observation time was 5.9 ± 1.4 years. Implant survival was 100%, and HAC survival was 97.5%. Over the observation period, one crown fracture was observed, necessitating refabricating of the restoration. Three minor biological complications were found. The overall mean FIPS score was 8.69 ± 1.12 points. CONCLUSIONS Within the limitations of this study, monolithic screw-retained HACs milled from lithium disilicate ceramics and bonded to titanium bases appeared to be a reliable treatment option over more than 3.5 years due to their low biological and technical complication rates.
Collapse
Affiliation(s)
- Oliver Schubert
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany
| | - Janosch Goob
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany
| | - Josef Schweiger
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany
| | - Jan-Frederik Güth
- Department of Prosthodontics, Center for Dentistry and Oral Medicine (Carolinum), Goethe-University Frankfurt am Main, Frankfurt am Main, Germany
| | - Daniel Edelhoff
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany
| | - Tobias Graf
- Department of Prosthodontics, Center for Dentistry and Oral Medicine (Carolinum), Goethe-University Frankfurt am Main, Frankfurt am Main, Germany
| |
Collapse
|
30
|
Hyldahl E, Gotfredsen K, Lynge Pedersen AM, Storgård Jensen S. Survival and Success of Dental Implants in Patients with Autoimmune Diseases: a Systematic Review. J Oral Maxillofac Res 2024; 15:e1. [PMID: 38812949 PMCID: PMC11131373 DOI: 10.5037/jomr.2024.15101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Accepted: 03/31/2024] [Indexed: 05/31/2024]
Abstract
Objectives The purpose of this systematic review is to disclose the impact of autoimmune diseases and their medical treatment on dental implant survival and success. Material and Methods A literature search was conducted using MEDLINE (PubMed), The Cochrane Library and Embase up to December 6th, 2021. Any clinical study on patients with an autoimmune disease in whom implant therapy was performed was eligible. The quality of included studies was assessed using the Newcastle-Ottawa Scale. For each autoimmune disease group, data synthesis was divided into three groups: 1) overall results of the autoimmune disease, 2) overall results of corresponding control groups and 3) overall results of the autoimmune disease with a concomitant autoimmune disease (a subgroup of group 1). Descriptive statistics were used. Results Of 4,865 identified articles, 67 could be included and mainly comprising case reports and retrospective studies with an overall low quality. Implant survival rate was 50 to 100% on patient and implant level after a weighted mean follow-up of 17.7 to 68.1 months. Implant success was sporadically reported. Data on immunosuppressive medication were too heterogeneously reported to allow detailed analysis. Conclusions Overall, a high implant survival rate was reported in patients with autoimmune diseases. However, the identified studies were characterized by a low quality. No conclusions could be made regarding implant success and the effect of immunosuppressants due to heterogeneous reporting.
Collapse
Affiliation(s)
- Emil Hyldahl
- Oral Surgery, Section for Oral Biology and Immunopathology, Department of Odontology, Faculty of Health and Medical Sciences, University of Copenhagen, CopenhagenDenmark.
| | - Klaus Gotfredsen
- Oral Rehabilitation, Section for Oral Health, Society and Technology, Department of Odontology, Faculty of Health and Medical Sciences, University of Copenhagen, CopenhagenDenmark.
| | - Anne Marie Lynge Pedersen
- Oral Pathology and Medicine, Section for Oral Biology and Immunopathology, Department of Odontology, Faculty of Health and Medical Sciences, University of Copenhagen, CopenhagenDenmark.
| | - Simon Storgård Jensen
- Oral Surgery, Section for Oral Biology and Immunopathology, Department of Odontology, Faculty of Health and Medical Sciences, University of Copenhagen, CopenhagenDenmark.
| |
Collapse
|
31
|
Chaar MS, Passia N, Becker M, Kern M. Long-term clinical outcome of three-unit fixed-fixed posterior zirconia ceramic inlay-retained FDPs with a modified design. J Dent 2024; 140:104781. [PMID: 37981045 DOI: 10.1016/j.jdent.2023.104781] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2023] [Revised: 11/11/2023] [Accepted: 11/16/2023] [Indexed: 11/21/2023] Open
Abstract
OBJECTIVES To assess the long-term clinical outcome of posterior inlay-retained fixed dental prostheses (IRFDPs) with a modified design made from zirconia ceramic. METHODS In 30 patients thirty 3-unit IRFDPs were placed to replace 7 premolars (4 in the maxilla, 3 in the mandible), and 23 first molars (15 in the maxilla, 8 in the mandible). Preparations were accomplished in agreement with the general principles for ceramic inlay restorations and modified with a short retainer-wing bevel preparation within the enamel at the buccal and oral sides. The frameworks were milled from 3Y-TZP ceramic, and the pontics were veneered with feldspathic ceramic. All IRFDPs were bonded with a phosphate monomer containing luting resin after air-abrasion of the intaglio surfaces. The patients were recalled 6-12 months after placement, and then annually. Kaplan-Meier analysis was used to calculate the survival and complication rates of the IRFDPs. RESULTS The mean observation time was 10.6 ± 1.5 years. The 10-year cumulative survival rate was 89% with 4 failures, two of them were due to deep secondary caries with loss of retention, one due to repeated debonding with enamel fractures, and one due to generalized progressive periodontitis. The most common complication was chipping of the veneering ceramic (20.1%). Eighteen IRFDPs were free of any type of complication up to 15.4 years, which corresponds to a 10-year cumulative success rate of 70.4%. CONCLUSION The long-term clinical performance of modified IRFDPs made of veneered zirconia ceramics was favorable after 10 years, therefore, they represent a treatment alternative to replace posterior single missing teeth. CLINICAL SIGNIFICANCE Zirconia-based IRFDPs fabricated in the modified design may represent a substance-preserving alternative to conventional posterior FDPs to replace posterior single missing teeth, particularly in cases where implants cannot be placed, and when the adjacent teeth already have small restorations or defects.
Collapse
Affiliation(s)
- M Sad Chaar
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University at Kiel, Arnold-Heller-Str. 16, Kiel 24105, Germany.
| | - Nicole Passia
- Department of Prosthodontics, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Merlind Becker
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University at Kiel, Arnold-Heller-Str. 16, Kiel 24105, Germany
| | - Matthias Kern
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University at Kiel, Arnold-Heller-Str. 16, Kiel 24105, Germany
| |
Collapse
|
32
|
Le Ferrand H, Goh BT, Teoh SH. Nacre-like ceramic composites: Properties, functions and fabrication in the context of dental restorations. Acta Biomater 2024; 173:66-79. [PMID: 38016510 DOI: 10.1016/j.actbio.2023.11.036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Revised: 11/02/2023] [Accepted: 11/22/2023] [Indexed: 11/30/2023]
Abstract
Dental restorations are in increasing demand, yet their success rate strongly decreases after 5-10 years post-implantation, attributed in part to mismatching properties with the surrounding buccal environment that causes failures and wear. Among current research to address this issue, biomimetic approaches are promising. Nacre-like ceramic composites are particularly interesting because they combine multiple antagonistic properties making them more resistant to failure in harsh environment than other materials. With the rapid progress in 3D printing producing nacre-like structures has open up new opportunities not yet realised. In this paper, nacre-like composites of various compositions are reviewed in the context of hypothetical biomimetic dental restorations. Their structural, functional and biological properties are compared with those of dentin, enamel, and bone to determine which composition would be the most suitable for each of the 3 mineralized regions found in teeth. The role of complex microstructures and mineral orientations are discussed as well as 3D printing methods that allow the design and fabrication of such complex architectures. Finally, usage of these processes and anticipated prospects for next generation biomimetic dental replacements are discussed to suggest future research directions in this area. STATEMENT OF SIGNIFICANCE: With the current ageing population, dental health is a major issue and current dental restorations still have shortcomings. For the next generation of dental restorations, more biomimetic approaches would be desirable to increase their durability. Among current materials, nacre-like ceramic composites are interesting because they can approach the various structural properties found in the different parts of our teeth. Furthermore, it is also possible to embed self-sensing functionalities to enable monitoring of oral health. Finally, new recent 3D printing technologies now permit the fabrication of complex shapes with local compositions and local microstructures. With this current status of the research, we anticipate new dental restorations designs and highlight the remaining gaps and issues to address.
Collapse
Affiliation(s)
- Hortense Le Ferrand
- School of Mechanical and Aerospace Engineering, 50 Nanyang Avenue, Nanyang Technological University, 639798 Singapore; Singapore 3D Printing Centre, 50 Nanyang Avenue, Nanyang Technological University, 639798 Singapore.
| | - Bee Tin Goh
- National Dental Research Institute Singapore (NDRIS), National Dental Centre Singapore, 5 Second Hospital Avenue, 168938, Singapore
| | - Swee-Hin Teoh
- Centre for Advanced Medical Engineering, School of Materials Science and Engineering, Hunan University, China
| |
Collapse
|
33
|
Alqutaibi AY, Algabri RS, Elawady D, Ibrahim WI. Advancements in artificial intelligence algorithms for dental implant identification: A systematic review with meta-analysis. J Prosthet Dent 2023:S0022-3913(23)00783-7. [PMID: 38158266 DOI: 10.1016/j.prosdent.2023.11.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 11/20/2023] [Accepted: 11/21/2023] [Indexed: 01/03/2024]
Abstract
STATEMENT OF PROBLEM The evidence regarding the application of artificial intelligence (AI) in identifying dental implant systems is currently inconclusive. The available studies present varying results and methodologies, making it difficult to draw definitive conclusions. PURPOSE The purpose of this systematic review with meta-analysis was to comprehensively analyze and evaluate articles that investigate the application of AI in identifying and classifying dental implant systems. MATERIAL AND METHODS An electronic systematic review was conducted across 3 databases: MEDLINE/PubMed, Cochrane, and Scopus. Additionally, a manual search was performed. The inclusion criteria consisted of peer-reviewed studies investigating the accuracy of AI-based diagnostic tools on dental radiographs for identifying and classifying dental implant systems and comparing the results with those obtained by expert judges using manual techniques-the search strategy encompassed articles published until September 2023. The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool was used to assess the quality of included articles. RESULTS Twenty-two eligible articles were included in this review. These articles described the use of AI in detecting dental implants through conventional radiographs. The pooled data showed that dental implant identification had an overall accuracy of 92.56% (range 90.49% to 94.63%). Eleven studies showed a low risk of bias, 6 demonstrated some concern risk, and 5 showed a high risk of bias. CONCLUSIONS AI models using panoramic and periapical radiographs can accurately identify and categorize dental implant systems. However, additional well-conducted research is recommended to identify the most common implant systems.
Collapse
Affiliation(s)
- Ahmed Yaseen Alqutaibi
- Associate Professor, Department of Prosthodontics and Implant Dentistry, College of Dentistry, Taibah University, Al Madinah, Saudi Arabia; and Associate Professor, Department of Prosthodontics, College of Dentistry, Ibb University, Ibb, Yemen.
| | - Radhwan S Algabri
- Assistant professor, Department of Prosthodontics, Faculty of Dentistry, Ibb University, Ibb, Yemen; and Assistant professor, Department of Prosthodontics, Faculty of Dentistry, National University, Ibb, Yemen
| | - Dina Elawady
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, MSA University, 6th of October City, Egypt
| | - Wafaa Ibrahim Ibrahim
- Associate Professor, Department of Prosthodontics, Faculty of Oral and Dental Medicine, Delta University for Science and Technology, Mansoura, Egypt
| |
Collapse
|
34
|
Han JW, Han JW, Pyo SW, Kim S. Impact of profile angle of CAD-CAM abutment on the marginal bone loss of implant-supported single-tooth posterior restorations. J Prosthet Dent 2023:S0022-3913(23)00780-1. [PMID: 38129258 DOI: 10.1016/j.prosdent.2023.11.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 11/19/2023] [Accepted: 11/20/2023] [Indexed: 12/23/2023]
Abstract
STATEMENT OF PROBLEM Although the emergence angle has been related to marginal bone loss, information regarding the relationship between the transmucosal configuration of a computer-aided design and computer-aided manufacturing (CAD-CAM) abutment at specific subgingival levels and the amount of marginal bone loss is lacking. PURPOSE The purpose of this retrospective clinical study was to evaluate the influence of CAD-CAM abutment profile angles, measured at different subgingival positions, on the marginal bone loss of posterior single-tooth implant-supported restorations. MATERIAL AND METHODS A total of 260 posterior single-tooth implant-supported restorations using CAD-CAM abutments were analyzed in 206 patients. All implants had internal conical seal connections with a platform-switched design. The following data were extracted using digital periapical radiography: emergence profile, profile angle at distance ranges of 0 to 1 mm, 1 to 2 mm, and 2 to 3 mm from the implant-abutment junction, and peri-implant marginal bone loss (MBL). The MBL was measured from the time of delivery of the restorations up to 7 years or more. A linear mixed model was applied to investigate whether there was a significant difference in MBL based on the emergence profile and time, followed by the Bonferroni correction post hoc test. A Pearson correlation analysis was used to analyze the correlation between the profile angle and MBL at each distance range. The cut-off points for each distance range were determined by using the c-index, and independent t tests were conducted based on these cut-off values to evaluate the statistical differences (α=.05 for all statistical analyses). RESULTS The convex emergence profile exhibited greater MBL than the concave and straight profiles at each follow-up visit (P<.001). A significant correlation was found between the profile angle and MBL in the 0 to 1 mm, 1 to 2 mm distance ranges. However, no significant correlation was found between the profile angle and MBL in the 2 to 3 mm distance range (P>.05). The cut-off points were 34 degrees at the mesial and 28 degrees at the distal in the 0 to 1 mm range, and 33 and 20 degrees at the mesial and distal in the 1 to 2 mm range. CONCLUSIONS The profile angle near the implant-abutment junction and the type of emergence profile of the CAD-CAM abutment were closely associated with MBL in implants with internal conical seal connection with a platform switch design.
Collapse
Affiliation(s)
- Jin-Won Han
- Former Graduate student, Yonsei University College of Dentistry, Seoul, Republic of Korea
| | - Jin-Woo Han
- Graduate student, Yonsei University College of Dentistry, Seoul, Republic of Korea
| | - Se-Wook Pyo
- Clinical Assistant Professor, Department of Prosthodontics, Gangnam Severance Dental Hospital, Yonsei University College of Dentistry, Seoul, Republic of Korea
| | - Sunjai Kim
- Professor and Chairman, Department of Prosthodontics, Gangnam Severance Dental Hospital, Yonsei University College of Dentistry, Seoul, Republic of Korea.
| |
Collapse
|
35
|
Zumstein K, Waller T, Hämmerle CHF, Jung RE, Benic G, Mühlemann S. Clinical performance of monolithic zirconia crowns on titanium-zirconium reduced-diameter implants in the molar area: Interim data at three years of a randomized controlled trial. Clin Oral Implants Res 2023; 34:1354-1362. [PMID: 37668109 DOI: 10.1111/clr.14179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 08/10/2023] [Accepted: 08/23/2023] [Indexed: 09/06/2023]
Abstract
AIM The aim of the present study was (i) to evaluate the clinical performance of reduced-diameter implants placed in the molar area and (ii) to test whether monolithic zirconia implant-supported crowns lead to similar clinical outcomes compared to porcelain-fused-to-metal crowns. MATERIALS AND METHODS A total of 76 patients needing a single implant crown in the posterior region were recruited. All patients received a titanium-zirconium reduced-diameter implant (Straumann Roxolid, Tissue Level, Standard Plus, diameter 3.3 mm, regular neck) randomly allocated to receive either a (1) monolithic zirconia crown (test) or (2) porcelain-fused-to-metal crown (control). Implant survival, prosthetic outcomes, and patient-reported outcomes were assessed at crown delivery and after 3 years of follow-up. Marginal bone levels (MBL) as well as clinical parameters including probing depth (PD), bleeding on probing (BOP), and plaque levels (PCR) were also recorded. RESULTS A total of 59 patients were available at the 3-year follow-up; 32 patients with a monolithic zirconia crown (TEST) and 27 patients with a porcelain-fused-to-metal crown (CONTROL). 14 implants (11 implant fractures/3 aseptic losses) were lost leading to an estimated implant survival rate of 80% ± 5.1% (95% CI 70.8%-90.8%). Prosthetic complications were limited to the control group and involved minor chippings. CONCLUSIONS This type of reduced-diameter implant to support single implant molar crowns in the molar area cannot be recommended. Monolithic zirconia crowns appear to be a viable option in the posterior region showing similar prosthetic outcomes to porcelain-fused-to-metal crowns.
Collapse
Affiliation(s)
- K Zumstein
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - T Waller
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - C H F Hämmerle
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - R E Jung
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - G Benic
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - S Mühlemann
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
36
|
Fujii Y, Hatori A, Minami S, Kanno Y, Hamada H, Miyazawa T, Chikazu D. Characteristics and Risk Factors for the Fracture of One-Piece Implants. J Maxillofac Oral Surg 2023; 22:1091-1098. [PMID: 38105858 PMCID: PMC10719176 DOI: 10.1007/s12663-023-02033-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Accepted: 10/16/2023] [Indexed: 12/19/2023] Open
Abstract
Objective The one-piece dental implant was originally designed to overcome the structural weaknesses of the two-piece implant. However, a fractured one-piece implant requires removal because the abutment cannot be repaired or replaced to support new prosthetic restorations. The aim of this study was to clarify the features and risk factors for fracture of the one-piece implant. Methods This study was designed as a retrospective case series research. The subjects were patients who were treated for fractures of the one-piece implant at a clinic in Japan between 2012 and 2021. Fractures of the one-piece implant were diagnosed by cone-beam computed tomography, and the association between age and duration from implant placement to fracture was analyzed by one-way ANOVA followed by the Tukey test. Results Eighteen patients and 20 one-piece implants (under 39 years: 5 patients and 6 implants; 40-59 years: 7 patients and 7 implants; over 60 years: 6 patients and 7 implants) had fractures in their one-piece implants. Of the fractured implants, 11 had a diameter of 3 mm, and 9 had a diameter of 4 mm. The mean durations up to implant fracture were 662 days in the younger group, 1467 days in the middle group, and 1239 days in older group, and the duration was significantly shorter in the younger group. In addition, 83.3% of fracture implants in the younger group were in the molar region. All fractures of the one-piece implants occurred under the bone margin. Two patients had torus mandibularis, and 1 patient was had bruxism. Conclusions One-piece implants in younger patients that are located in the lower molar position are the most susceptible to implant fracture, and the fracture occurred under the bone margin in all cases.
Collapse
Affiliation(s)
- Yasuyuki Fujii
- Department of Oral and Maxillofacial Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-Ku, Tokyo, Japan
- Tokyo Ekimae Dental Clinic, 3-3-11 Kyobashi, Chuo-Ku, Tokyo, Japan
| | - Ayano Hatori
- Department of Oral and Maxillofacial Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-Ku, Tokyo, Japan
| | - Sakura Minami
- Department of Oral and Maxillofacial Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-Ku, Tokyo, Japan
| | - Yuki Kanno
- Tokyo Ekimae Dental Clinic, 3-3-11 Kyobashi, Chuo-Ku, Tokyo, Japan
- Department of Oral and Maxillofacial Surgery, Tokyo Women’s Medical University, 8-1 Kawada-Cho, Shinjuku-Ku, Tokyo, Japan
| | - Hayato Hamada
- Department of Oral and Maxillofacial Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-Ku, Tokyo, Japan
| | | | - Daichi Chikazu
- Department of Oral and Maxillofacial Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-Ku, Tokyo, Japan
| |
Collapse
|
37
|
Corbella S, Morandi B, Calciolari E, Alberti A, Francetti L, Donos N. The influence of implant position and of prosthetic characteristics on the occurrence of peri-implantitis: a retrospective study on periapical radiographs. Clin Oral Investig 2023; 27:7261-7271. [PMID: 37910236 PMCID: PMC10713669 DOI: 10.1007/s00784-023-05303-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Accepted: 10/02/2023] [Indexed: 11/03/2023]
Abstract
OBJECTIVE The present retrospective study aimed to investigate the influence of malposition on the occurrence of peri-implantitis. MATERIALS AND METHODS The study included clinical records of systemically healthy patients with single and partial implant-supported rehabilitations and at least 1-year post-loading follow-up. The parameters collected included implant-related factors, patient-related factors, site-related factors, and prosthesis-related factors. The radiographic measurements were taken by using a dedicated software and the diagnosis of peri-implantitis was made based on all the available clinical and radiographic data. Descriptive statistics were provided for all variables. Following an exploratory approach, an implant-level analysis of factors influencing the occurrence of peri-implantitis was done through a multilevel multivariate logistic regression (mixed). RESULTS A total of 180 implants belonging to 90 subjects were randomly selected. Malposition showed no statistically significant association with the occurrence of peri-implantitis. According to the multi-level analysis, the parameters that were significantly associated with peri-implantitis included presence / history of periodontitis (OR = 5.945, 95% CI: 1.093 - 32.334, P = 0.039) and presence of an emergence profile angle ≥ 45° (OR = 9.094, 95% CI: 2.017 - 40.995, P = 0.005). CONCLUSIONS Implant malposition, as defined following Buser's criteria (2004), did not influence the occurrence of peri-implantitis in the selected cohort. Conversely, history of periodontitis and presence of a prosthetic emergence profile with an angle ≥ 45° were correlated to an increased risk of peri-implantitis.
Collapse
Affiliation(s)
- Stefano Corbella
- Department of Biomedical, Surgical and Dental Sciences, Università degli Studi di Milano, Milan, Italy.
- IRCCS Ospedale Galeazzi Sant'Ambrogio, Milan, Italy.
| | - Benedetta Morandi
- Department of Biomedical, Surgical and Dental Sciences, Università degli Studi di Milano, Milan, Italy
- IRCCS Ospedale Galeazzi Sant'Ambrogio, Milan, Italy
| | - Elena Calciolari
- Centre for Oral Clinical Research, Institute of Dentistry, Faculty of Medicine and Dentistry, Queen Mary University of London, London, UK
- Centro di Odontoiatria, Dipartimento di Medicina e Chirurgia, Università di Parma, Parma, Italy
| | - Alice Alberti
- Department of Biomedical, Surgical and Dental Sciences, Università degli Studi di Milano, Milan, Italy
- IRCCS Ospedale Galeazzi Sant'Ambrogio, Milan, Italy
| | - Luca Francetti
- Department of Biomedical, Surgical and Dental Sciences, Università degli Studi di Milano, Milan, Italy
- IRCCS Ospedale Galeazzi Sant'Ambrogio, Milan, Italy
| | - Nikolaos Donos
- Centre for Oral Clinical Research, Institute of Dentistry, Faculty of Medicine and Dentistry, Queen Mary University of London, London, UK
| |
Collapse
|
38
|
Gadzo N, Ioannidis A, Naenni N, Hüsler J, Jung RE, Thoma DS. Survival and complication rates of two dental implant systems supporting fixed restorations: 10-year data of a randomized controlled clinical study. Clin Oral Investig 2023; 27:7327-7336. [PMID: 37906305 PMCID: PMC10713755 DOI: 10.1007/s00784-023-05323-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Accepted: 10/10/2023] [Indexed: 11/02/2023]
Abstract
OBJECTIVES To compare clinical, radiographic, biological and technical long-term outcomes of two types of dental implants over a period of 10 years. MATERIALS AND METHODS Ninety-eight implants were placed in 64 patients, randomly allocated to one of two manufacturers (AST and STM). All implants were loaded with fixed restorations. Outcome measures were assessed at implant insertion (Ti), at baseline examination (TL), at 1, 3, 5, 8 and 10 (T10) years. Data analysis included survival, bone level changes, complications and clinical measures. RESULTS Re-examination was performed in 43 patients (23 AST and 20 STM) at 10 years. The implant level analysis was based on 37 (AST) and 32 (STM) implants. Survival rates of 100% were obtained for both groups. The median changes of the marginal bone levels between baseline and T10 (the primary endpoint) amounted to a loss of 0.07 mm for group AST and a gain of 0.37 mm for group STM (intergroup p = 0.008). Technical complications occurred in 27.0% of the implants in group AST and in 15.6% in group STM. The prevalence of peri-implant mucositis was 29.7% (AST) and 50.1% (STM). The prevalence of peri-implantitis amounted to 0% (AST) and 6.3% (STM). CONCLUSIONS Irrespective of the implant system used, the survival rates after 10 years were high. Minimal bone level changes were observed, statistically significant but clinically negligible in favor of STM. Technical complications were more frequently encountered in group AST, while group STM had a higher prevalence of peri-implant mucositis.
Collapse
Affiliation(s)
- Naida Gadzo
- Clinic of Reconstructive Dentistry, Center for Dental Medicine, University of Zurich, 8032, Zurich, CH, Switzerland
| | - Alexis Ioannidis
- Clinic of Reconstructive Dentistry, Center for Dental Medicine, University of Zurich, 8032, Zurich, CH, Switzerland
| | - Nadja Naenni
- Clinic of Reconstructive Dentistry, Center for Dental Medicine, University of Zurich, 8032, Zurich, CH, Switzerland
| | - Jürg Hüsler
- Clinic of Reconstructive Dentistry, Center for Dental Medicine, University of Zurich, 8032, Zurich, CH, Switzerland
| | - Ronald E Jung
- Clinic of Reconstructive Dentistry, Center for Dental Medicine, University of Zurich, 8032, Zurich, CH, Switzerland
| | - Daniel S Thoma
- Clinic of Reconstructive Dentistry, Center for Dental Medicine, University of Zurich, 8032, Zurich, CH, Switzerland.
- Department of Periodontology, Research Institute for Periodontal Regeneration, College of Dentistry, Yonsei University, Seoul, Korea.
| |
Collapse
|
39
|
Wang W, Yu X, Wang F, Wu Y. Clinical efficacy of computer-assisted zygomatic implant surgery: A systematic scoping review. J Prosthet Dent 2023:S0022-3913(23)00717-5. [PMID: 38007293 DOI: 10.1016/j.prosdent.2023.10.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 10/28/2023] [Accepted: 10/30/2023] [Indexed: 11/27/2023]
Abstract
STATEMENT OF PROBLEM Digital technology can improve the success of zygomatic implant (ZI) surgery. However, the reliability and efficacy of computer-assisted zygomatic implant surgery (CAZIS) need further analysis. PURPOSE The purpose of this scoping review was to provide an overview of the placement accuracy, implant survival, and complications of CAZIS. MATERIAL AND METHODS A systematic search of English and Mandarin Chinese publications up to May 2023 was conducted in PubMed, Web of Science, Embase, and Wanfang database. The nonpeer-reviewed literature was searched in the trial register (clinicaltrials.gov). Clinical studies and cadaver studies on CAZIS were included. After data extraction and collection, the findings were critically reviewed, analyzed, interpreted, and discussed. RESULTS Forty-one studies met the inclusion criteria. After excluding publications with duplicate data, retaining the most recent, 28 articles were included in this scoping review. Of these, 18 were on static computer-assisted zygomatic implant surgery (sCAZIS), 8 on dynamic computer-assisted zygomatic implant surgery (dCAZIS), and 2 on robot-assisted zygomatic implant surgery (rAZIS). Excluding the outliers, the mean deviations of ZIs in the sCAZIS group (with 8 articles reporting implant placement accuracy, 183 ZIs involved) were: 1.15 ±1.37 mm (coronal deviation), 2.29 ±1.95 mm (apical deviation), and 3.32 ±3.36 degrees (angular deviation). The mean deviations of dCAZIS (3 articles, 251 ZIs) were: 1.60 ±0.74 mm (coronal), 2.27 ±1.05 mm (apical), and 2.89 ±1.69 degrees (angular). The mean deviations of rAZIS (2 articles, 5 ZIs) were: 0.82 ±0.21 mm (coronal), 1.25 ±0.52 mm (apical), and 1.46 ±0.35 degrees (angular). Among the CAZIS reported in the literature, the implant survival rate was high (96.3% for sCAZIS, 98.2% for dCAZIS, and 100% for rAZIS, specified in 14 of 21 clinical studies). The incidence of complications was low, but, because of the few relevant studies (4/21 specified), valid conclusions regarding complications could not be drawn. CONCLUSIONS CAZIS has demonstrated clinical efficacy with high implant survival rates and placement accuracy. Of the 3 guided approaches, rAZIS showed the smallest 3-dimensional deviation.
Collapse
Affiliation(s)
- Wenying Wang
- Graduate student, Second Dental Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai, PR China
| | - Xinbo Yu
- Undergraduate student, Second Dental Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai, PR China
| | - Feng Wang
- Professor, Second Dental Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai, PR China
| | - Yiqun Wu
- Professor, Second Dental Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai, PR China.
| |
Collapse
|
40
|
Khaohoen A, Sornsuwan T, Chaijareenont P, Poovarodom P, Rungsiyakull C, Rungsiyakull P. Biomaterials and Clinical Application of Dental Implants in Relation to Bone Density-A Narrative Review. J Clin Med 2023; 12:6924. [PMID: 37959389 PMCID: PMC10649288 DOI: 10.3390/jcm12216924] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Revised: 10/29/2023] [Accepted: 11/02/2023] [Indexed: 11/15/2023] Open
Abstract
Titanium has been the material of choice for dental implant fixtures due to its exceptional qualities, such as its excellent balance of rigidity and stiffness. Since zirconia is a soft-tissue-friendly material and caters to esthetic demands, it is an alternative to titanium for use in implants. Nevertheless, bone density plays a vital role in determining the material and design of implants. Compromised bone density leads to both early and late implant failures due to a lack of implant stability. Therefore, this narrative review aims to investigate the influence of implant material/design and surgical technique on bone density from both biomechanical and biological standpoints. Relevant articles were included for analysis. Dental implant materials can be fabricated from titanium, zirconia, and PEEK. In terms of mechanical and biological aspects, titanium is still the gold standard for dental implant materials. Additionally, the macro- and microgeometry of dental implants play a role in determining and planning the appropriate treatment because it can enhance the mechanical stress transmitted to the bone tissue. Under low-density conditions, a conical titanium implant design, longer length, large diameter, reverse buttress with self-tapping, small thread pitch, and deep thread depth are recommended. Implant material, implant design, surgical techniques, and bone density are pivotal factors affecting the success rates of dental implant placement in low-density bone. Further study is required to find the optimal implant material for a clinical setting's bone state.
Collapse
Affiliation(s)
- Angkoon Khaohoen
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand; (A.K.); (P.C.); (P.P.)
| | - Tanapon Sornsuwan
- Department of Restorative Dentistry, Faculty of Dentistry, Naresuan University, Phitsanulok 65000, Thailand;
| | - Pisaisit Chaijareenont
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand; (A.K.); (P.C.); (P.P.)
| | - Pongsakorn Poovarodom
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand; (A.K.); (P.C.); (P.P.)
| | - Chaiy Rungsiyakull
- Department of Mechanical Engineering, Faculty of Engineering, Chiang Mai University, Chiang Mai 50200, Thailand;
| | - Pimduen Rungsiyakull
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand; (A.K.); (P.C.); (P.P.)
| |
Collapse
|
41
|
Padhye NM, Calciolari E, Zuercher AN, Tagliaferri S, Donos N. Survival and success of zirconia compared with titanium implants: a systematic review and meta-analysis. Clin Oral Investig 2023; 27:6279-6290. [PMID: 37740825 PMCID: PMC10630218 DOI: 10.1007/s00784-023-05242-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Accepted: 09/05/2023] [Indexed: 09/25/2023]
Abstract
OBJECTIVE This systematic review assessed the available evidence on the survival and success rate of zirconia and titanium implants. As secondary outcomes, aesthetic, radiographic and clinical parameters, as well as biological and mechanical complications, were considered. MATERIALS AND METHODS A systematic search was performed up to March 2022 to identify CCTs/RCTs comparing zirconia and titanium implants with a minimum of 12 months of follow-up. Meta-analysis was performed when ≥ 2 articles with similar characteristics were retrieved. RESULTS Four published articles with two RCTs (2 different patient populations) with 100 zirconia and 99 titanium implants that were followed up over 12-80 months were selected out of the 6040 articles. A non-statistically significant difference between zirconia and titanium implant survival at 12 months was suggested (P = 0.0938). The success rates were 57.5-93.3% and 57.1-100% for zirconia and titanium implants, respectively. The pink aesthetic score (PES) was higher for zirconia (10.33 ± 2.06 to 11.38 ± 0.92) compared to titanium implants (8.14 ± 3.58 to 11.56 ± 1.0). CONCLUSION Based on the 2 RCTs retrieved in the literature, similar survival rates were reported for zirconia and titanium implants in the short term (12 months of follow-up). Future RCTs are warranted to evaluate the long-term outcomes of zirconia implants. CLINICAL RELEVANCE Zirconia implants may be the procedure of choice, particularly in the aesthetic zone, since they show a similar survival and success rate as titanium implants on a short-term follow-up. TRIAL REGISTRATION Systematic review registration number-CRD42021288704 (PROSPERO).
Collapse
Affiliation(s)
- Ninad Milind Padhye
- Centre for Oral Clinical Research, Institute of Dentistry, Faculty of Medicine and Dentistry, Queen Mary University of London (QMUL), London, UK
| | - Elena Calciolari
- Centre for Oral Clinical Research, Institute of Dentistry, Faculty of Medicine and Dentistry, Queen Mary University of London (QMUL), London, UK
- Department of Medicine and Surgery, Centre of Dentistry, University of Parma, Parma, Italy
| | - Anina Nives Zuercher
- Centre for Oral Clinical Research, Institute of Dentistry, Faculty of Medicine and Dentistry, Queen Mary University of London (QMUL), London, UK
- Clinic of Reconstructive Dentistry, Centre of Dental Medicine, Zurich, Switzerland
| | - Sara Tagliaferri
- Department of Medicine and Surgery, University of Parma, Parma, Italy
- Center of Excellence for Toxicological Research, CERT, University of Parma, Parma, Italy
| | - Nikos Donos
- Centre for Oral Clinical Research, Institute of Dentistry, Faculty of Medicine and Dentistry, Queen Mary University of London (QMUL), London, UK.
| |
Collapse
|
42
|
Bhumpattarachai S, Kan JYK, Goodacre CJ, Swamidass RS, Al-Ardah A, Rungcharassaeng K, Lozada J. Effects of cyclic loading on loss of abutment screw torque of angled screw channel single implant crowns on narrow diameter implants. J Prosthet Dent 2023; 130:741.e1-741.e9. [PMID: 37689572 DOI: 10.1016/j.prosdent.2023.08.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Revised: 08/01/2023] [Accepted: 08/02/2023] [Indexed: 09/11/2023]
Abstract
STATEMENT OF PROBLEM Screw access channels that emerge on the facial aspect of anterior screw-retained implant crowns can compromise esthetics. Recently, angled screw channels (ASCs) have been developed that can alter screw access channel angulations to improve esthetics. While ASCs can be used on narrow-diameter implants, information is limited on the loss of abutment screw torque on narrow-diameter implants with ASCs. PURPOSE The purpose of this in vitro study was to compare the loss of abutment screw torque after thermocycling and the cyclic loading of ASCs from 3 different companies connected to narrow-diameter implants. MATERIAL AND METHODS A total of 40 narrow-diameter implants (NobelReplace Conical Connection 3.5×11.5 mm) were mounted individually in acrylic resin blocks and divided equally into 4 groups. The first group, NB-0 (Control), consisted of screw-retained zirconia crowns fabricated on ASCs at 0-degree angulation (n=10). The other 3 groups consisted of a total of 30 screw-retained zirconia crowns fabricated on ASCs at 20-degree angulation: NB-20 (Angulated Screw Channel Solutions), ATL-20 (Atlantis Custom Base Solution with angulated screw access), and DA-20 (Dynamic TiBase). Each crown was secured on the mounted implant with its corresponding titanium base insert and screw and then tightened to the manufacturer's recommended torque with a digital torque gauge. The initial reverse torque value (RTVI) was obtained and recorded at baseline. Subsequently, a new set of screws were tightened to recommended values, and each specimen underwent thermocycling and then cyclic loading at 0 to 100 N at 10 Hz for 1 million cycles to simulate 1year of functional loading. After cyclic loading, the final reverse torque values (RTVF) were recorded and compared with the RTVI to evaluate the percentage torque loss (PTLF). Statistical analysis was performed using the Kruskal-Wallis analysis, Rank base analysis of covariance (ANCOVA), and the Tukey HSD post hoc comparisons (α=.05). RESULTS Significant differences were found for the PTLF among all groups after cyclic loading (P<.001). The PTLF in ATL-20 (51.4%) was significantly higher than in NB-0 (22.2%) (P<.001) and NB-20 (29.2%) (P=.010). No significant difference was found in the PTLF among other groups (P>.05). CONCLUSIONS The abutment screw torque loss after cyclic loading of the ASCs on narrow diameter implants among the 4 groups did not perform comparably. The largest percentage torque loss was recorded for the ATL-20 group. The NB-20 group demonstrated the lowest percentage torque loss. DA-20 showed percentage torque loss less than ATL-20; however, its RTVF was the lowest.
Collapse
Affiliation(s)
- Sasiya Bhumpattarachai
- Assistant Professor, Department of General Dentistry, School of Dentistry, Loma Linda University, Loma Linda, Calif; Research Associate, Advanced Dental Education Program in Implant Dentistry, School of Dentistry, Loma Linda University, Loma Linda, Calif.
| | - Joseph Y K Kan
- Professor, Advanced Dental Education Program in Implant Dentistry, School of Dentistry, Loma Linda University, Loma Linda, Calif
| | - Charles J Goodacre
- Distinguished Professor, Advanced Dental Education Program in Implant Dentistry, School of Dentistry, Loma Linda University, Loma Linda, Calif
| | - Rajesh S Swamidass
- Assistant Clinical Professor, Advanced Dental Education Program in Implant Dentistry, School of Dentistry, Loma Linda University, Loma Linda, Calif
| | - Aladdin Al-Ardah
- Associate Professor, Advanced Dental Education Program in Implant Dentistry, School of Dentistry, Loma Linda University, Loma Linda, Calif
| | | | - Jaime Lozada
- Professor and Program Director, Advanced Education Program in Implant Dentistry, School of Dentistry, Loma Linda University, Loma Linda, Calif
| |
Collapse
|
43
|
Molinero-Mourelle P, Peter L, Gaviria AS, Fonseca M, Schimmel M, Katsoulis J. Tactile misfit detection ability at the implant-abutment interface of internal connection dental implants: an in-vitro study. Acta Odontol Scand 2023; 81:591-596. [PMID: 37319413 DOI: 10.1080/00016357.2023.2223715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 06/05/2023] [Accepted: 06/06/2023] [Indexed: 06/17/2023]
Abstract
OBJECTIVE The aim of this in-vitro study was to investigate the tactile assessment ability at the implant impression-taking stage. METHODS Thirty clinicians (18 novices, 12 experts) were included for a tactile fit assessment by using a used/new probe (tip diameter 100 µm/20 µm). Six implant replicas and related impression copings of two internal connection implant systems were used, each with a perfect fit (0 µm) and defined vertical micro gaps of 8, 24, 55, 110 and 220 µm at the interface. Statistical analysis was performed using descriptive methods and non-parametric tests with a focus on specificity (ability to detect perfect fit), sensitivity (ability to detect misfit), and predictive values. P-values <5% were considered statistically significant. RESULTS The tactile assessment showed a mean total sensitivity for the Straumann and Nobel Biocare systems of 83% and 80% with a used probe, and 91% and 92% with a new probe, respectively. The mean total specificities were 33% and 20% with a used probe and 17% and 3% with a new probe, respectively. No statistical significance was observed between novice and expert clinicians concerning their tactile assessment ability. CONCLUSIONS The ability to detect a perfect fit (specificity) with a probe was very poor for both implant systems and impaired with the use of a new probe. The use of a new probe improved the gap detection ability (sensitivity) significantly at the expense of the specificity. A combination of additional chairside techniques with training and calibration could improve clinicians' ability to correctly assess the fit/misfit at the implant-abutment interface.
Collapse
Affiliation(s)
- Pedro Molinero-Mourelle
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Conservative Dentistry and Orofacial Prosthodontics, Complutense University of Madrid, Madrid, Spain
| | - Lukas Peter
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Ana Sol Gaviria
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Manrique Fonseca
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Joannis Katsoulis
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Preventive and Restorative Sciences, Robert Schattner Center, University of Pennsylvania School of Dental Medicine, Philadelphia, PA, USA
| |
Collapse
|
44
|
Alseddiek A, Al-Zordk W, Attia A. Retention of hybrid-abutment-crowns with offset implant placement: influence of Crown materials and Ti-base height. BMC Oral Health 2023; 23:784. [PMID: 37875871 PMCID: PMC10594673 DOI: 10.1186/s12903-023-03490-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Accepted: 10/04/2023] [Indexed: 10/26/2023] Open
Abstract
BACKGROUND The purpose of the current study was to assess the impact of three esthetic CAD/CAM material, titanium base height and their interaction on the retention strength of a hybrid-abutment-crown. METHODS A total of 42 hybrid-abutment crowns with identical external geometries were designed in CAD software to fit two different Ti-Base abutment heights (n = 42/abutment height): either short (S) with 4 mm (n = 21) or long (L) 7 mm (n = 21) height. Each main group was divided into 3 subgroups (n = 7), according to esthetic crown material, Zirconia (Z), Lithium disilicate (L) and Hybrid ceramic (V). A universal primer and an adhesive resin cement were used for bonding according to the manufacturer instructions. Artificial aging in form of water storage (30 days), chewing simulation (50,000-cycles, 49 N, 1.67 Hz) and thermal cyclic (5000 cycles at 5-55 °C) were applied, specimens were pulled-out under tension load in (N) using a universal testing machine. Two and one-way ANOVA and Post Hoc Tukey test were used for statistical analysis. RESULTS Long lithium disilicate (LL) group showed the highest retention (738.7 ± 178.5) followed by short lithium disilicate (LS) group (688.6 ± 169.9). Meanwhile, short zirconia (ZS) showed the lowest retention strength (231.1 ± 86.9). CONCLUSION CAD/CAM fabricated lithium disilicate hybrid-abutment-crown can be used instead of conventional crowns over implant abutment. Etchable ceramics are recommended as a material of choice for CAD/CAM fabricated hybrid-abutment-crowns instead of zirconia in terms of retention durability.
Collapse
Affiliation(s)
- Ahmed Alseddiek
- Department of Fixed Prosthodontics, Faculty of Dentistry, Mansoura University, El Gomhouria St, P.O. Box 35516, Mansoura, Dakahlia Governorate, Egypt
| | - Walid Al-Zordk
- Department of Fixed Prosthodontics, Faculty of Dentistry, Mansoura University, El Gomhouria St, P.O. Box 35516, Mansoura, Dakahlia Governorate, Egypt
| | - Ahmed Attia
- Department of Fixed Prosthodontics, Faculty of Dentistry, Mansoura University, El Gomhouria St, P.O. Box 35516, Mansoura, Dakahlia Governorate, Egypt.
| |
Collapse
|
45
|
Pesce P, Del Fabbro M, Menini M, De Giovanni E, Annunziata M, Khijmatgar S, Canullo L. Effects of abutment materials on peri-implant soft tissue health and stability: A network meta-analysis. J Prosthodont Res 2023; 67:506-517. [PMID: 37081626 DOI: 10.2186/jpr.jpr_d_22_00223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/22/2023]
Abstract
PURPOSE This systematic review aimed to evaluate the effect of the abutment material on peri-implant soft tissue health and stability. STUDY SELECTION An electronic and hand search was conducted until February 2022. Only prospective randomized trials (RCTs) and controlled clinical trials (CCTs) comparing titanium abutments with abutments made of different materials, with a follow-up of at least 6 months, were selected by two independent reviewers. Data on marginal bone loss (MBL) and peri-implant tissue indexes, i.e., plaque index (PI), bleeding on probing (BOP), probing depth (PD), and recession (REC), were collected. The risk of bias for RCTs and non-RCTs was evaluated according to the tool reported in the Cochrane Handbook for Systematic Reviews of Interventions and the ROBINS-I tool, respectively. Both pairwise and network meta-analyses (NMA) were performed. RESULTS We included 18 relevant studies from 1,437 identified studies. Overall, 612 patients were treated, and 848 abutments were inserted. Five studies presented a low risk of bias. Pairwise meta-analysis showed that, as compared to titanium, zirconia abutments presented a significantly reduced MBL (0.20 mm, 95% Confidence Interval CI [0.14-0.26], P < 0.00001). No significant differences were found for the other outcomes. In the NMA, zirconia abutments demonstrated an 83.3% probability of achieving the highest rank in PI, an 87.0% in BOP, and a 65.0% in PD outcome, suggesting that zirconia abutments generally performed better than titanium and alumina abutments. CONCLUSIONS Within the limits of the present study, zirconia abutments seem a viable alternative to titanium ones.
Collapse
Affiliation(s)
- Paolo Pesce
- Department of Surgical Sciences (DISC), Division of Prosthodontics and Implant Prosthodontics, University of Genoa, L. Rosanna Benzi, Genoa, Italy
| | - Massimo Del Fabbro
- Department of Biomedical, Surgical, and Dental Sciences, University of Milan, Milan, Italy
- Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Maria Menini
- Department of Surgical Sciences (DISC), Division of Prosthodontics and Implant Prosthodontics, University of Genoa, L. Rosanna Benzi, Genoa, Italy
| | - Emanuele De Giovanni
- Department of Surgical Sciences (DISC), Division of Prosthodontics and Implant Prosthodontics, University of Genoa, L. Rosanna Benzi, Genoa, Italy
| | - Marco Annunziata
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania Luigi Vanvitelli, Naples, Italy
| | - Shahnawaz Khijmatgar
- Department of Biomedical, Surgical, and Dental Sciences, University of Milan, Milan, Italy
| | - Luigi Canullo
- Department of Surgical Sciences (DISC), Division of Prosthodontics and Implant Prosthodontics, University of Genoa, L. Rosanna Benzi, Genoa, Italy
| |
Collapse
|
46
|
Park JH, Moon HS, Jung HI, Hwang J, Choi YH, Kim JE. Deep learning and clustering approaches for dental implant size classification based on periapical radiographs. Sci Rep 2023; 13:16856. [PMID: 37803022 PMCID: PMC10558577 DOI: 10.1038/s41598-023-42385-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 09/09/2023] [Indexed: 10/08/2023] Open
Abstract
This study investigated two artificial intelligence (AI) methods for automatically classifying dental implant diameter and length based on periapical radiographs. The first method, deep learning (DL), involved utilizing the pre-trained VGG16 model and adjusting the fine-tuning degree to analyze image data obtained from periapical radiographs. The second method, clustering analysis, was accomplished by analyzing the implant-specific feature vector derived from three key points coordinates of the dental implant using the k-means++ algorithm and adjusting the weight of the feature vector. DL and clustering model classified dental implant size into nine groups. The performance metrics of AI models were accuracy, sensitivity, specificity, F1-score, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve (AUC-ROC). The final DL model yielded performances above 0.994, 0.950, 0.994, 0.974, 0.952, 0.994, and 0.975, respectively, and the final clustering model yielded performances above 0.983, 0.900, 0.988, 0.923, 0.909, 0.988, and 0.947, respectively. When comparing the AI model before tuning and the final AI model, statistically significant performance improvements were observed in six out of nine groups for DL models and four out of nine groups for clustering models based on AUC-ROC. Two AI models showed reliable classification performances. For clinical applications, AI models require validation on various multicenter data.
Collapse
Affiliation(s)
- Ji-Hyun Park
- Department of Prosthodontics, Yonsei University College of Dentistry, Yonsei-ro 50-1, Seodaemun-gu, Seoul, 03722, Korea
| | - Hong Seok Moon
- Department of Prosthodontics, Yonsei University College of Dentistry, Yonsei-ro 50-1, Seodaemun-gu, Seoul, 03722, Korea
| | - Hoi-In Jung
- Department of Preventive Dentistry and Public Oral Health, Yonsei University College of Dentistry, Seoul, 03722, Korea
| | - JaeJoon Hwang
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Dental Research Institute, Pusan National University, Busan, 50612, Korea
| | - Yoon-Ho Choi
- School of Computer Science and Engineering, Pusan National University, Busan, 46241, Korea
| | - Jong-Eun Kim
- Department of Prosthodontics, Yonsei University College of Dentistry, Yonsei-ro 50-1, Seodaemun-gu, Seoul, 03722, Korea.
| |
Collapse
|
47
|
Del Castillo R, Gutiérrez-Garrido L, Padial-Molina M, Galindo-Moreno P. Screw-retained internal connection zirconia CAD-CAM abutments in single implant reconstructions: Results of a 1-year prospective case series study. J Prosthodont 2023; 32:679-688. [PMID: 36882991 DOI: 10.1111/jopr.13674] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 02/24/2023] [Accepted: 02/24/2023] [Indexed: 03/09/2023] Open
Abstract
PURPOSE To evaluate the clinical and radiographic outcomes of single-tooth implant restorations using one-piece, internally connected, screw-retained, computer-aided design and computer-aided manufactured monolithic zirconia restorations fabricated on regular diameter implants. MATERIAL AND METHODS Following a 2-stage surgical procedure, 22 implants placed in anterior and posterior areas in 21 partially edentulous patients (mean age of 55 years; 9 males/12 females) were evaluated in terms of plaque index, pocket probing depth, bleeding on probing, level of oral hygiene (OH), signs of mucositis/peri-implantitis, esthetic score (ES), gingival zenith position (GZP), papilla index score, the thickness of peri-implant gingiva, radiographic marginal bone loss, and technical complications. Implants and restorations were prospectively followed from the insertion of the restoration (baseline), up to 12-months post-loading. RESULTS A 100% implant survival rate resulted after loading; one implant was lost before loading. Clinically, patients performed an adequate OH, and tissues were kept healthy. Probing depth showed a slightly lower value at baseline compared to any follow-up examination (2.26 [0.94] at baseline vs. 2.53 [0.66] mm at 12 months). ES, GZP, and the thickness of the peri-implant gingiva improved throughout the course of the study. Radiographically, average marginal bone level (MBL) was 0.40 (0.40) mm after 1-year follow-up with no differences in average MBL at all time points. Technically, after 1 year of clinical function, neither abutment fracture nor any other serious complications occurred. Hence, prosthetic reconstruction survival rate was 100%. CONCLUSIONS Clinical outcomes of single-tooth implant restorations using internally connected, screw-retained, computer-aided design and computer-aided manufacturing monolithic zirconia abutments can be considered a reliable treatment alternative after 1-year clinical observation.
Collapse
Affiliation(s)
- Rafael Del Castillo
- Department of Prosthodontics, Eastman Institute for Oral Health, University of Rochester, Rochester, New York, USA
| | | | - Miguel Padial-Molina
- Department of Oral Surgery and Implant Dentistry, School of Dentistry, University of Granada, Granada, Spain
- Instituto de Investigación Biosanitaria., IBS, University of Granada., Granada, Spain
| | - Pablo Galindo-Moreno
- Department of Oral Surgery and Implant Dentistry, School of Dentistry, University of Granada, Granada, Spain
- Instituto de Investigación Biosanitaria., IBS, University of Granada., Granada, Spain
| |
Collapse
|
48
|
Lee MS, Chiang CP, Tseng WY, Ho CLJ. Rapid retrieval of fractured implant abutment screws with a custom-made screwdriver. J Dent Sci 2023; 18:1952-1955. [PMID: 37799893 PMCID: PMC10547980 DOI: 10.1016/j.jds.2023.05.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Indexed: 10/07/2023] Open
Affiliation(s)
- Ming-Shu Lee
- School of Dentistry, National Taiwan University, Taipei, Taiwan
- Department of Prosthodontics, National Taiwan University Hospital, College of Medicine, National Taiwan University, Taipei, Taiwan
| | - Chun-Pin Chiang
- School of Dentistry, National Taiwan University, Taipei, Taiwan
- Department of Dentistry, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien, Taiwan
- Department of Dentistry, National Taiwan University Hospital, College of Medicine, National Taiwan University, Taipei, Taiwan
| | - Wan-Yu Tseng
- School of Dentistry, National Taiwan University, Taipei, Taiwan
- Department of Dentistry, National Taiwan University Hospital, College of Medicine, National Taiwan University, Taipei, Taiwan
- Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University, Taipei, Taiwan
| | - Chih-Liang Julian Ho
- Department of Orthodontics, Far Eastern Memorial Hospital, New Taipei City, Taiwan
- Department of Orthodontics, National Taiwan University Hospital, Taipei, Taiwan
| |
Collapse
|
49
|
Kim DS, Lau LN, Kim JW, Yeo ISL. Measurement of proximal contact of single crowns to assess interproximal relief: A pilot study. Heliyon 2023; 9:e20403. [PMID: 37767497 PMCID: PMC10520794 DOI: 10.1016/j.heliyon.2023.e20403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Revised: 08/23/2023] [Accepted: 09/22/2023] [Indexed: 09/29/2023] Open
Abstract
Background It is common for dental technicians to adjust the proximal surface of adjacent teeth on casts when fabricating single crowns. However, whether the accuracy of the proximal contact is affected if this step is eliminated is unclear. Objective To evaluate the accuracy of the proximal contact of single crowns for mandibular first molars fabricated from four different restorative materials, without adjustment of the proximal surface of the adjacent teeth by the laboratory/dental technician. Methods This study was in vitro; all the clinical procedures were conducted on a dentoform. The mandibular first molar tooth on the dentoform was prepared using diamond burs and a high speed handpiece. Twenty single crowns were fabricated, five for each group (monolithic zirconia, lithium disilicate, metal ceramic, and cast gold). No proximal surface adjacent to the definitive crowns was adjusted for tight contact in the dental laboratory. Both the qualitative analyses, using dental floss and shimstock, and the quantitative analyses, using a stereo microscope, were performed to evaluate the accuracy of the proximal contact of the restoration with the adjacent teeth. In the quantitative analysis, one-way analysis of variance was used to compare mean values at a significance level of 0.05. Results In quantitative analysis, the differences between the proximal contact tightness of the four groups was not statistically significant (P = 0.802 for mesial contacts, P = 0.354 for distal contacts). In qualitative analysis, in most crowns, dental floss passed through the contact with tight resistance and only one film of shimstock could be inserted between the adjacent teeth and the restoration. However, one specimen from the cast gold crown had open contact. Conclusions Even without proximal surface adjustment of the adjacent teeth during the crown fabrication process, adequate proximal contact tightness between the restoration and adjacent teeth could be achieved.
Collapse
Affiliation(s)
| | - Le Na Lau
- Department of Prosthodontics, Seoul National University School of Dentistry, Seoul, Korea
| | - Jong-Woong Kim
- Department of Prosthodontics, Seoul National University School of Dentistry, Seoul, Korea
| | - In-Sung Luke Yeo
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Korea
| |
Collapse
|
50
|
Nguyen O, Lee SJ, Lee JD. Influence of varying titanium base abutment heights on retention of zirconia restorations: An in vitro study. J Prosthet Dent 2023; 130:604.e1-604.e5. [PMID: 37633730 DOI: 10.1016/j.prosdent.2023.07.034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Revised: 07/27/2023] [Accepted: 07/31/2023] [Indexed: 08/28/2023]
Abstract
STATEMENT OF PROBLEM Implant manufacturers have introduced titanium base (Ti-Base) abutments with increased abutment heights, ostensibly, to increase the retention of the bonded restoration and to improve overall strength. However, evidence regarding the effects of increasing Ti-Base height on improving retention is lacking. PURPOSE The purpose of this in vitro study was to evaluate the effect of different Ti-Base abutment heights on the retention of zirconia implant-supported crowns. MATERIAL AND METHODS Thirty Ti-Base abutments of the same diameter and heights of 3.5 mm (n=10), 4.5 mm (n=10), and 5.5 mm (n=10), were used for testing. Zirconia restorations were cemented onto the Ti-Base abutments with a resin cement after treatment with a 10-methacryloyloxydecyl dihydrogen phosphate primer by a single operator using a positioning device. The zirconia-Ti-Base restorations were tightened to an implant analog embedded in an autopolymerizing resin block. The specimens were placed and tested in a universal testing machine for pull-out testing. Retention was measured by recording the force at load drop. Statistical analysis was performed using 1-way analysis of variance with the Tukey method for pairwise comparisons. RESULTS The abutment height had a significant effect on retention (P=.010). Ti-Base abutments of 4.5 and 5.5 mm had significantly greater retention than Ti-Base abutments of 3.5 mm (P=.020, P=.040, respectively). However, Ti-Base abutments of 4.5 and 5.5 mm in height were statistically similar (P=.890). CONCLUSIONS An increase in the height of Ti-Base abutments above the standard 3.5 mm height significantly improved the retention of the overlying restoration.
Collapse
Affiliation(s)
- Olivia Nguyen
- Graduate student, Advanced Graduate Education in Prosthodontics, Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Mass
| | - Sang J Lee
- Associate Professor, Department of Restorative Dentistry and Biomaterial Sciences, Harvard School of Dental Medicine, Boston, Mass
| | - Jason D Lee
- Instructor, Department of Restorative Dentistry and Biomaterial Sciences, Harvard School of Dental Medicine, Boston, Mass.
| |
Collapse
|