1
|
Bruze M, Hopkins K, Dahlin J, Olsson K, Åstrand J, Svedman C, Ofenloch R, Antelmi A. Increased rates of fragrance allergy in fibromyalgia individuals tested with the Swedish baseline patch test series. J Eur Acad Dermatol Venereol 2023; 37:104-113. [PMID: 36018078 DOI: 10.1111/jdv.18562] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Accepted: 07/27/2022] [Indexed: 12/15/2022]
Abstract
BACKGROUND Contact allergy can manifest in a variety of ways clinically. Systemic contact allergy may occasionally present with pain in muscles and joints. Fibromyalgia is a chronic rheumatic disease characterized by pain and with virtually unknown aetiology. OBJECTIVES The aim of this study was to investigate the contact allergy rates to the sensitizers in a baseline series and compare with corresponding rates in dermatitis patients and the general population. METHODS Patch testing with the Swedish baseline series was performed in 120 individuals with fibromyalgia. Fisher's exact test was used for pair-wise comparisons of contact allergy rates between the fibromyalgia group and two control groups, dermatitis patients and individuals in the general population. RESULTS Contact allergy was significantly more common in the fibromyalgia group compared to the general population concerning nickel and the fragrance markers Myroxolon pereirae and fragrance mix I. There were fewer allergic reactions to preservatives in the fibromyalgia group compared with the dermatitis group. CONCLUSIONS Myroxolon pereirae and fragrance mix I represent besides fragrance allergy also allergy to flavouring substances which indicate that oral exposure to flavouring substances and hygiene products might be important for sensitization and possibly elicitation of systemic contact allergy symptoms in fibromyalgia individuals.
Collapse
Affiliation(s)
- Magnus Bruze
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Katharine Hopkins
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden.,Department of Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Jakob Dahlin
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Karin Olsson
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Jacqueline Åstrand
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Cecilia Svedman
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Robert Ofenloch
- Occupational Dermatology, Department of Dermatology, University Hospital Heidelberg, Heidelberg, Germany
| | - Annarita Antelmi
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| |
Collapse
|
2
|
Sukakul T, Bruze M, Mowitz M, Antelmi A, Boonchai W, Dahlin J, Hamnerius N, Hauksson I, Lejding T, Svedman C. Simultaneous patch testing with fragrance markers in the baseline series and the ingredients of fragrance mixes ‐ an update from southern Sweden. Contact Dermatitis 2022; 86:514-523. [PMID: 35152428 PMCID: PMC9314710 DOI: 10.1111/cod.14072] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Revised: 02/09/2022] [Accepted: 02/10/2022] [Indexed: 11/28/2022]
Abstract
Background Regularly updating the prevalence of fragrance contact allergy (CA) is important. Patch testing with fragrance markers in the baseline series and the ingredients of fragrance mixes (FMs) is still debated. Objectives To update the prevalence and clinical characteristics of patients with fragrance CA. To establish the results of patch testing with individual allergens of FMs. Methods A retrospective analysis of 3539 patients with dermatitis who were patch tested with the baseline series and FMs ingredients during 2016 to 2020 was performed. Results The prevalence of fragrance CA was 13%. About 10% of these patients with fragrance CA would be missed if the individual ingredients were not tested. Unlike hydroxyisohexyl 3‐cyclohexene carboxaldehyde, there was no decreasing trend of CA to Evernia prunastri (oakmoss) extract after the EU regulation came into force. Patients with CA from only one ingredient of the mixes or having a weak positive reaction to the ingredients were significantly missed when tested with only the fragrance markers in the baseline series. Conclusions Patch testing with individual fragrance allergens is crucial for experts to expand knowledge in the fragrance CA field. The concentrations of the allergens in FMs may need to be adjusted to detect patients with fragrance CA, since some were significantly overlooked.
Collapse
Affiliation(s)
- Thanisorn Sukakul
- Department of Occupational and Environmental Dermatology Lund University, Skåne University Hospital Malmö Sweden
| | - Magnus Bruze
- Department of Occupational and Environmental Dermatology Lund University, Skåne University Hospital Malmö Sweden
| | - Martin Mowitz
- Department of Occupational and Environmental Dermatology Lund University, Skåne University Hospital Malmö Sweden
| | - Annarita Antelmi
- Department of Occupational and Environmental Dermatology Lund University, Skåne University Hospital Malmö Sweden
| | - Waranya Boonchai
- Department of Dermatology Faculty of Medicine Siriraj Hospital, Mahidol University Bangkok Thailand
| | - Jakob Dahlin
- Department of Occupational and Environmental Dermatology Lund University, Skåne University Hospital Malmö Sweden
| | - Nils Hamnerius
- Department of Occupational and Environmental Dermatology Lund University, Skåne University Hospital Malmö Sweden
| | - Inese Hauksson
- Department of Occupational and Environmental Dermatology Lund University, Skåne University Hospital Malmö Sweden
| | - Tina Lejding
- Department of Occupational and Environmental Dermatology Lund University, Skåne University Hospital Malmö Sweden
| | - Cecilia Svedman
- Department of Occupational and Environmental Dermatology Lund University, Skåne University Hospital Malmö Sweden
| |
Collapse
|
3
|
Quaade AS, Simonsen AB, Halling AS, Thyssen JP, Johansen JD. Prevalence, incidence, and severity of hand eczema in the general population - A systematic review and meta-analysis. Contact Dermatitis 2021; 84:361-374. [PMID: 33548072 DOI: 10.1111/cod.13804] [Citation(s) in RCA: 68] [Impact Index Per Article: 22.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 01/27/2021] [Accepted: 01/30/2021] [Indexed: 12/14/2022]
Abstract
Accurate assessments of the burden of hand eczema (HE) in the general population are important for public awareness and intervention. The aim of this systematic review and meta-analysis was to provide updated estimates of prevalence and incidence, alongside additional epidemiological endpoints on HE in the general population. PubMed, Embase and Web of Science were searched for studies reporting the prevalence and/or incidence of HE in the general population. Proportion meta-analyses were performed to calculate pooled estimates of prevalence, incidence, severity, and the proportion of individuals with HE and a history of atopic dermatitis. Sixty-six studies were included in the quantitative analysis encompassing 568 100 individuals. The pooled estimates for lifetime, 1-year, and point prevalence were 14.5% (95% confidence interval [CI]: 12.6-16.5), 9.1% (95% CI: 8.4-9.8) and 4.0% (95% CI: 2.6-5.7), respectively. The pooled incidence rate of HE was 7.3 cases/1000 person-years (95% CI: 5.4-9.5). The occurrence of HE was 1.5-2 times higher in females than males. More than one third suffered from moderate/severe disease and around one third had a history of atopic dermatitis. HE was a recurrent, long-lasting disease with an average age at onset of the early- to mid-twenties. In conclusion; HE is a highly prevalent disease in the general population and carries a significant risk of long-term or chronic disease.
Collapse
Affiliation(s)
- Anna S Quaade
- National Allergy Research Centre, Department of Dermatology and Allergy, Herlev and Gentofte Hospital, University of Copenhagen, Hellerup, Denmark
| | - Anne B Simonsen
- National Allergy Research Centre, Department of Dermatology and Allergy, Herlev and Gentofte Hospital, University of Copenhagen, Hellerup, Denmark.,Department of Dermatology and Allergy, Herlev and Gentofte Hospital, University of Copenhagen, Hellerup, Denmark
| | - Anne-Sofie Halling
- Department of Dermatology and Allergy, Herlev and Gentofte Hospital, University of Copenhagen, Hellerup, Denmark
| | - Jacob P Thyssen
- National Allergy Research Centre, Department of Dermatology and Allergy, Herlev and Gentofte Hospital, University of Copenhagen, Hellerup, Denmark.,Department of Dermatology and Allergy, Herlev and Gentofte Hospital, University of Copenhagen, Hellerup, Denmark
| | - Jeanne D Johansen
- National Allergy Research Centre, Department of Dermatology and Allergy, Herlev and Gentofte Hospital, University of Copenhagen, Hellerup, Denmark
| |
Collapse
|
4
|
Brinca A, Cabral R, Gonçalo M. Contact allergy to local anaesthetics-value of patch testing with a caine mix in the baseline series. Contact Dermatitis 2012; 68:156-62. [DOI: 10.1111/j.1600-0536.2012.02149.x] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
5
|
Basko-Plluska JL, Thyssen JP, Schalock PC. Cutaneous and systemic hypersensitivity reactions to metallic implants. Dermatitis 2011. [PMID: 21504692 DOI: 10.2310/6620.2011.10055] [Citation(s) in RCA: 146] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Cutaneous reactions to metal implants, orthopedic or otherwise, are well documented in the literature. The first case of a dermatitis reaction over a stainless steel fracture plate was described in 1966. Most skin reactions are eczematous and allergic in nature, although urticarial, bullous, and vasculitic eruptions may occur. Also, more complex immune reactions may develop around the implants, resulting in pain, inflammation, and loosening. Nickel, cobalt, and chromium are the three most common metals that elicit both cutaneous and extracutaneous allergic reactions from chronic internal exposure. However, other metal ions as well as bone cement components can cause such hypersensitivity reactions. To complicate things, patients may also develop delayed-type hypersensitivity reactions to metals (ie, in-stent restenosis, prosthesis loosening, inflammation, pain, or allergic contact dermatitis) following the insertion of intravascular stents, dental implants, cardiac pacemakers, or implanted gynecologic devices. Despite repeated attempts by researchers and clinicians to further understand this difficult area of medicine, the association between metal sensitivity and cutaneous allergic reactions remains to be fully understood. This review provides an update of the current knowledge in this field and should be valuable to health care providers who manage patients with conditions related to this field.
Collapse
|
6
|
|
7
|
Abstract
Contact dermatitis is a significant health problem affecting the elderly. Impaired epidermal barrier function and delayed cutaneous recovery after insult enhances susceptibility to both irritants and allergens. Exposure to more numerous potential sensitizers and for greater durations influences the rate of allergic contact dermatitis in this population. Medical co-morbidities, including stasis dermatitis and venous ulcerations, further exacerbate this clinical picture. However, while these factors tend to increase the degree of sensitization in the elderly, waning immunity can actually decrease such a propensity. This interplay of both intrinsic and extrinsic factors makes a generalization on trends for contact dermatitis in older adults challenging. The literature has varying reports on the overall incidence of allergic contact dermatitis with advancing age. Nevertheless, it does clearly show that sensitivity to topical medicaments increases with age. Irritant contact dermatitis studies are more consistent, with less reactivity (to irritants) in older compared with younger skin. Diagnosis of both irritant and allergic contact dermatitis is based on a thorough history, complete skin examination, and comprehensive patch testing. The mainstay of therapy is avoidance of the offending chemical substances and the use of topical along with systemic therapies, depending on the severity of the condition.
Collapse
Affiliation(s)
- Amy V Prakash
- Division of Dermatology, Mayo Clinic and Mayo Foundation, Rochester, Minnesota 55905, USA
| | | |
Collapse
|
8
|
Thyssen JP, Johansen JD, Linneberg A, Menné T. The epidemiology of hand eczema in the general population - prevalence and main findings. Contact Dermatitis 2010; 62:75-87. [DOI: 10.1111/j.1600-0536.2009.01669.x] [Citation(s) in RCA: 300] [Impact Index Per Article: 21.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
9
|
Nardelli A, D’Hooghe E, Drieghe J, Dooms M, Goossens A. Allergic contact dermatitis from fragrance components in specific topical pharmaceutical products in Belgium. Contact Dermatitis 2009; 60:303-13. [DOI: 10.1111/j.1600-0536.2009.01542.x] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
10
|
Abstract
Many women and men now dye their hair. p-Phenylenediamine (PPD) is a frequent and important component of permanent hair dye products; exposure to it may cause allergic contact sensitization, acute dermatitis, and severe facial oedema. To increase our understanding of PPD allergy, we reviewed published literature containing PPD patch test data from dermatitis patients and individuals in the general population. This was performed to estimate the median prevalence and the weighted average of PPD sensitization and thereby assess the burden of PPD-containing hair care products on health. Literature was examined using PubMed-MEDLINE, Biosis, and Science Citation Index. The median prevalence among dermatitis patients was 4.3% in Asia, 4% in Europe, and 6.2% in North America. A widespread increase in the prevalence of PPD sensitization was observed among Asian dermatitis patients. In Europe, a decrease in the 1970s was replaced by a plateau with steady, high prevalences ranging between 2% and 6%. The prevalence remained high in North America, although a decreasing tendency was observed. Contact allergy to PPD is an important health issue for both women and men. More stringent regulation and enforcement are required as public health measures to reduce the burden of disease that exposure to PPD has brought to populations.
Collapse
Affiliation(s)
- Jacob Pontoppidan Thyssen
- National Allergy Research Centre, Department of Dermatology, Gentofte University Hospital, Ledreborg Allé 40, 1. Gentofte 2820, Denmark.
| | | | | |
Collapse
|
11
|
Thyssen J, Menné T, Linneberg A, Johansen J. Contact sensitization to fragrances in the general population: a Koch’s approach may reveal the burden of disease. Br J Dermatol 2009; 160:729-35. [DOI: 10.1111/j.1365-2133.2008.09022.x] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
12
|
Current World Literature. Curr Opin Allergy Clin Immunol 2008; 8:360-3. [DOI: 10.1097/aci.0b013e32830abac8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
13
|
Honari G, Ellis SG, Wilkoff BL, Aronica MA, Svensson LG, Taylor JS. Hypersensitivity reactions associated with endovascular devices. Contact Dermatitis 2008; 59:7-22. [PMID: 18537993 DOI: 10.1111/j.1600-0536.2008.01351.x] [Citation(s) in RCA: 85] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Golara Honari
- Department of Dermatology, Cleveland Clinic, Cleveland, Ohio 44195, USA
| | | | | | | | | | | |
Collapse
|
14
|
Ekqvist S, Svedman C, Möller H, Kehler M, Pripp CM, Björk J, Gruvberger B, Holmström E, Gustavsson CG, Bruze M. High frequency of contact allergy to gold in patients with endovascular coronary stents. Br J Dermatol 2007; 157:730-8. [PMID: 17711524 DOI: 10.1111/j.1365-2133.2007.08119.x] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND Stent implantation is an effective method for treatment of atherosclerotic disease. Factors predisposing to in-stent restenosis are still largely unknown. Contact allergy to metal ions eluted from the stent has been suggested to be a risk factor. OBJECTIVES To explore whether there is a possible induction of contact allergy to metals used in stents among patients with a stainless steel stent containing nickel (Ni stent) and patients with a gold-plated stent (Au stent). METHODS Adults (n = 484) treated with coronary stent implantation participated in the study with patch testing. The study design was retrospective and cross-sectional with no assessment of contact allergy before stenting. Age- and sex-matched patch-tested patients with dermatitis (n = 447) served as controls. RESULTS Of Au-stented patients, 54 of 146 (37%) were allergic to gold compared with 85 of 447 (19%) controls (P < 0.001). Within the stented population there were no statistically significant differences in contact allergy to gold or nickel between Ni-stented and Au-stented patients. In multivariate models where other risk factors for contact allergy to gold were considered, the Au stent showed a trend towards statistical significance (odds ratio 1.43, 95% confidence interval 0.95-2.16; P = 0.09). CONCLUSIONS As the frequency of contact allergy to gold is higher in stented patients independent of stent type it suggests a previous sensitization. However, several pieces of circumstantial evidence as well as statistical analysis indicate the possibility of sensitization in the coronary vessel by the Au stent. Ni stents and Au stents should not be ruled out as risk factors for induction of contact allergy to these metals.
Collapse
Affiliation(s)
- S Ekqvist
- Department of Occupational and Environmental Dermatology, Malmö University Hospital, Lund University, 205 02 Malmö, Sweden.
| | | | | | | | | | | | | | | | | | | |
Collapse
|