1
|
Baudet A, Lizon J, Florentin A, Mortier É. Initial waterline contamination by Pseudomonas aeruginosa in newly installed dental chairs. Microbiol Spectr 2024; 12:e0396223. [PMID: 38652098 DOI: 10.1128/spectrum.03962-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Accepted: 04/08/2024] [Indexed: 04/25/2024] Open
Abstract
Water contamination in dental unit waterlines (DUWLs) is a potential source of healthcare-associated infection during dental care. The aim of this study was to evaluate the microbiological quality of DUWLs water from newly installed dental chairs in a French University Hospital. The microbiological quality of water from 24 new DUWLs initially disinfected by ICX Renew-prior to use of the dental units for patient treatment-was assessed for total culturable aerobic bacteria at 22°C and 36°C, Legionella sp., Pseudomonas aeruginosa, and total coliforms. Among the 24 samples analyzed, 21 were compliant with the water quality levels: 19 had no bacteria, and 2 contained only 4 and 1 CFU/mL for total culturable aerobic bacteria at 22°C and 36°C, respectively. Three samples were non-compliant due to contamination by P. aeruginosa (4, 2, and 2 CFU/100 mL). Controlling and preventing the microbiological contamination of DUWLs, especially by pathogenic bacteria, at the time of the installation of the new dental chairs are crucial to prevent healthcare-associated infection in dentistry. IMPORTANCE Dental unit waterlines (DUWLs) of new dental chairs may be contaminated before their first clinical use, so an initial shock disinfection is crucial at the time of their installation. The microbiological analyses are crucial to control the water quality of DUWLs before their first clinical use because their disinfection does not guarantee the elimination of all bacteria.
Collapse
Affiliation(s)
- Alexandre Baudet
- Faculté d'odontologie, Université de Lorraine, Nancy, France
- CHRU-Nancy, Service d'odontologie, Nancy, France
- Université de Lorraine, Inserm, INSPIIRE, Nancy, France
| | - Julie Lizon
- Département territorial d'hygiène et prévention du risque infectieux (DTPRI), CHRU-Nancy, Nancy, France
| | - Arnaud Florentin
- Université de Lorraine, Inserm, INSPIIRE, Nancy, France
- Département territorial d'hygiène et prévention du risque infectieux (DTPRI), CHRU-Nancy, Nancy, France
- Département d'hygiène, des risques environnementaux et associés aux soins (DHREAS), Faculté de Médecine, Université de Lorraine, Nancy, France
| | - Éric Mortier
- Faculté d'odontologie, Université de Lorraine, Nancy, France
- CHRU-Nancy, Service d'odontologie, Nancy, France
- CNRS, IJL, Université de Lorraine, Nancy, France
| |
Collapse
|
2
|
Dallalana ES, Monteiro RM, Oliveira VDC, Bim FL, Bim LL, Castro DT, Macedo AP, Watanabe E. The long-term effect of sub-boiling water on dental unit waterlines and its ability to control cross-contamination in dentistry. Dent Mater J 2023; 42:700-707. [PMID: 37612094 DOI: 10.4012/dmj.2023-051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/25/2023]
Abstract
This study investigated the effect of water at high temperature on the physical and mechanical properties of polyurethane and on biofilm removal, aiming for its applicability in dental unit waterlines. The evaluations were carried out after simulating a 1-year period of daily immersion and measured changes in color, microhardness, surface roughness, and tensile strength before and after reproducing a disinfection protocol. For antibiofilm activity measurement, fragments of waterline were contaminated with Pseudomonas aeruginosa and submitted to the disinfection protocols. Relative to effects on the physical and mechanical properties, immersion in water at 60°C did not promote changes in color and tensile strength. However, lower values were observed for microhardness and increased values for surface roughness. Regarding antibiofilm action, water at 60°C significantly reduced the microbial load and promoted substantial changes in cells morphology. In conclusion, disinfection with water at 60°C demonstrated possible application in controlling cross-contamination in dentistry.
Collapse
Affiliation(s)
- Erick Silva Dallalana
- Human Exposome and Infectious Diseases Network (HEID), School of Nursing of Ribeirão Preto, University of São Paulo
| | - Rachel Maciel Monteiro
- Human Exposome and Infectious Diseases Network (HEID), School of Nursing of Ribeirão Preto, University of São Paulo
| | - Viviane de Cássia Oliveira
- Human Exposome and Infectious Diseases Network (HEID), School of Nursing of Ribeirão Preto, University of São Paulo
- Department of Dental Materials and Prostheses, School of Dentistry of Ribeirão Preto, University of São Paulo
| | - Felipe Lazarini Bim
- Human Exposome and Infectious Diseases Network (HEID), School of Nursing of Ribeirão Preto, University of São Paulo
| | - Lucas Lazarini Bim
- Human Exposome and Infectious Diseases Network (HEID), School of Nursing of Ribeirão Preto, University of São Paulo
| | | | - Ana Paula Macedo
- Department of Dental Materials and Prostheses, School of Dentistry of Ribeirão Preto, University of São Paulo
| | - Evandro Watanabe
- Human Exposome and Infectious Diseases Network (HEID), School of Nursing of Ribeirão Preto, University of São Paulo
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo
| |
Collapse
|
3
|
Khajezadeh M, Mohseni F, Khaledi A, Firoozeh A. Contamination of dental unit water lines (DUWL) with Legionella pneumophila and Pseudomonas aeruginosa; A Middle East systematic review and meta-analysis. Eur J Microbiol Immunol (Bp) 2023; 12:93-99. [PMID: 36626121 PMCID: PMC9869867 DOI: 10.1556/1886.2022.00023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Accepted: 12/12/2022] [Indexed: 01/11/2023] Open
Abstract
This review aimed to evaluate the contamination rate of dental unit waterlines (DUWL) with Pseudomonas aeruginosa and Legionella pneumophila in several countries in the Middle East.Literature search was conducted in databases such as PubMed, Scopus, Web of Science, and Google Scholar to gather studies published from the beginning of 2000 to 30th April 2020. Medical Subject Headings (MeSH) terms were; "Legionellosis"; "Legionnaire", "Legionellosis", "L. pneumophila", "dent", "dental", "dentistry", "Dental Unit Waterlines", "dental water", "DUWL", "Middle East", "P. aeruginosa", "Iran", "Turkey", "Iraq", and "Jordan". The search was independently conducted by two of the authors. Data was analyzed using Comprehensive Meta-Analysis software.Almost all studies included in this review reported a high rate of bacterial contamination of DUWL, which exceeded the current standard bacterial contamination level of <200 (CFU) mL-1 recommended by the American Dental Association (ADA). The combined prevalence of L. pneumophila from four countries (Iran, Jordan, Turkey, and Iraq) was 23.5% (95% Cl: 6.5-57.7), and the combined prevalence of P. aeruginosa was reported 21.7% (95% Cl: 7.1-50.1%).This study showed a high bacterial contamination rate of DUWL with opportunistic pathogens. So, it is recommended to prevent biofilm formation in DUWL, some measures should be extended by practical approaches allowing for water quality control and improvement on-site in the dental practices such as mobile filtration units, chlorination and disinfection chemicals.
Collapse
Affiliation(s)
- Masoud Khajezadeh
- Cellular and Molecular Gerash Research Center, Gerash University of Medical Sciences, Gerash, Iran
| | - Fatemeh Mohseni
- Department of Anesthesiology, Nursing School, Gerash University of Medical Sciences, Gerash, Iran,Department of Medical Education, Medical School, Tehran University of Medical Sciences, Tehran, Iran
| | - Azad Khaledi
- Infectious Diseases Research Center, Kashan University of Medical Sciences, Kashan, Iran,Department of Microbiology and Immunology, Faculty of Medicine, Kashan University of Medical Sciences, Kashan, Iran
| | - Arezoo Firoozeh
- Department of Microbiology, Mashhad University of Medical Sciences, Mashhad, Iran,Corresponding author. Tel.: +989304347901. E-mail:
| |
Collapse
|
4
|
Tesauro M, Consonni M, Grappasonni I, Lodi G, Mattina R. Dental unit water content and antibiotic resistance of Pseudomonas aeruginosa and Pseudomonas species: a case study. J Oral Microbiol 2022; 14:2107316. [PMID: 36034883 PMCID: PMC9415447 DOI: 10.1080/20002297.2022.2107316] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Background Many studies consider the contamination of dental unit waterlines (DUWLs), but few of them have studied the possible presence of antibiotic resistant Pseudomonas aeruginosa in the DUWLs. Aims Investigation of the presence of P. aeruginosa and Pseudomonas spp. strains in DUWLs and evaluation of their resistance to six antibiotics (ceftazidime, netilmicin, piperacillin/tazobactam, meropenem, levofloxacin, colistin sulfate) at a public dental clinic in Milan, Italy. Results Dental units were contaminated by P. aeruginosa with loads of 2–1,000 CFU/L and were mainly located on the mezzanine floor, with a range of 46–54%, while Pseudomonas spp. were primarily found on the first and second floors, ranging from 50 to 91%. P. aeruginosa was antibiotic resistant in 30% of the strains tested, andPseudomonas spp. in 31.8% . Cold water from controls was also contaminated by these microorganisms. Conclusion Monitoring antibiotic resistance in the water and adopting disinfection procedures on DUs are suggested within the Water Safety Plan.
Collapse
Affiliation(s)
- M. Tesauro
- Department of Biomedical, Surgical and Dental Sciences, Laboratory of Environmental Hygiene, Coordinating Research Centres Episomi University of Milan, University of Milan, Milan, Italy
| | - M. Consonni
- Department of Biomedical, Surgical and Dental Sciences, Laboratory of Environmental Hygiene, Coordinating Research Centres Episomi University of Milan, University of Milan, Milan, Italy
| | - I. Grappasonni
- School of Medicinal and Health Products Sciences, University of Camerino, Camerino, Italy
| | - G. Lodi
- Department of Biomedical, Surgical and Dental Sciences, Laboratory of Environmental Hygiene, Coordinating Research Centres Episomi University of Milan, University of Milan, Milan, Italy
| | - R. Mattina
- Department of Biomedical, Surgical and Dental Sciences, Laboratory of Environmental Hygiene, Coordinating Research Centres Episomi University of Milan, University of Milan, Milan, Italy
| |
Collapse
|
5
|
Microbiological Evaluation of Water Used in Dental Units. WATER 2022. [DOI: 10.3390/w14060915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
In modern dentistry, dental units are used for the treatment of patients’ teeth, and they need water to operate. Water circulates in a closed vessel system and finally reaches the mucous membranes of the patient as well as the dentist themselves. Therefore, the microbiological safety of this water should be a priority for physicians. This study aims to identify and determine the microbial count, expressed in CFU/mL, in water samples from various parts of the dental unit that are in direct contact with the patient. Thirty-four dental units located in dentistry rooms were analysed. The dentistry rooms were divided into three categories: surgical, conservative, and periodontal. It was found that in surgical rooms, the bacterial count was 1464.76 CFU/mL, and the most common bacterium was Staphylococcus pasteuri—23.88% of the total bacteria identified. In dentistry rooms where conservative treatments were applied, the average bacterial concentration was 8208.35 CFU/mL, and the most common bacterium was Ralsonia pickettii (26.31%). The periodontal rooms were also dominated by R. pickettii (45.13%), and the average bacterial concentration was 8743.08 CFU/mL. Fungi were also detected. Rhodotorula spp., Alternaria spp., and Candida parapsilosis were found to be the most common bacteria which are potentially harmful. This study indicates the need for effective decontamination of the water that is used in dental units and for constant monitoring of the level of contaminants present in the closed vessel system.
Collapse
|
6
|
Balfour-Lynn IM. Environmental risks of Pseudomonas aeruginosa-What to advise patients and parents. J Cyst Fibros 2020; 20:17-24. [PMID: 33323351 DOI: 10.1016/j.jcf.2020.12.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 12/03/2020] [Accepted: 12/03/2020] [Indexed: 10/22/2022]
Abstract
Pseudomonas aeruginosa (PsA) is commonly found in soil and water so is impossible to avoid completely. Parents/carers of children with cystic fibrosis (CF) are concerned about them acquiring PsA from the environment, and different families view risk differently. Our ethos is to enable children with CF to take part as much as possible in educational and fun home activities, in order to maintain their quality of life (and their family's), and not have them feel different from other children. This review presents advice for families as to what they must definitely avoid, what they must take precautions with but can allow, and what they must not avoid. It is mostly evidence-based, but where evidence is lacking it a consensus view from the Paediatric CF Unit at the Royal Brompton Hospital.
Collapse
Affiliation(s)
- I M Balfour-Lynn
- Department of Paediatric Respiratory Medicine, Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK.
| |
Collapse
|
7
|
Briancesco R, Paduano S, Semproni M, Vitanza L, Bonadonna L. Behavior of Pseudomonas aeruginosa and Enterobacter aerogenes in Water from Filter Jugs. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17218263. [PMID: 33182311 PMCID: PMC7664847 DOI: 10.3390/ijerph17218263] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 10/31/2020] [Accepted: 11/05/2020] [Indexed: 11/17/2022]
Abstract
Careless use conditions of filter jugs were applied to simulate and evaluate the behavior of two ubiquitous aquatic bacterial species, Pseudomonas aeruginosa and Enterobacter aerogenes. According to a reference protocol, nine different jugs of popular brands sold in the Italian market were used for the test. Separately, a suspension of the two bacteria was spiked in water used for filling the jugs. The concentration of the test organisms and total aerobic microbial count (TAMC) was measured daily in the filtered water along a period corresponding to the cartridge lifetime. Results showed a different trend of bacterial behavior. E. aerogenes was detectable exclusively on the first day after jug filling, while P. aeruginosa confirmed its persistence over time in all the jugs and its ability to potentially colonize surfaces and cartridges. The TAMC was detected at a concentration range from 102 to 107 CFU/100 mL in all the tests, high values that were not far from those raised in bottled flat natural mineral water weeks after bottling.
Collapse
Affiliation(s)
- Rossella Briancesco
- Department of Environment and Health, Italian National Institute of Health, 00161 Rome, Italy; (R.B.); (M.S.)
| | - Stefania Paduano
- Department of Biomedical, Metabolic and Neural Sciences, Section of Public Health, University of Modena and Reggio Emilia, 41125 Modena, Italy;
| | - Maurizio Semproni
- Department of Environment and Health, Italian National Institute of Health, 00161 Rome, Italy; (R.B.); (M.S.)
| | - Luca Vitanza
- Department of Public Health and Infectious Diseases, Microbiology Section, “Sapienza” University of Rome, 00161 Rome, Italy;
| | - Lucia Bonadonna
- Department of Environment and Health, Italian National Institute of Health, 00161 Rome, Italy; (R.B.); (M.S.)
- Correspondence:
| |
Collapse
|
8
|
Yoon HY, Lee SY. An Assessment of the Bacterial Diversity found in Dental Unit Waterlines using the Illumina MiSeq. Biocontrol Sci 2020; 24:201-212. [PMID: 31875612 DOI: 10.4265/bio.24.201] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
Water from the waterlines of dental units is often contaminated with bacteria but there have been few studies accurately assessing the diversity of these bacterial populations. The aim of our study was to assess the bacterial diversity present in water collected from dental unit waterlines using the Illumina MiSeq. Water was collected from two separate dental units located in a dental hospital and two units found in two separate private clinics in Gangneung-si, Korea. From the four water samples that were analyzed, a total of 233 bacterial genera were identified. The most abundant genera were Sphingomonas (25%), Halomonas (20%), Reyranella (8%), and Novosphingobium (6%). Halomonas was more prevalent in the two dental units located at the dental hospital, while Reyranella and Sphingomonas were more commonly found in the private dental clinics. Only 19 of the 233 identified genera were common between water samples from all dental units. Opportunistic pathogens were shown to account for 7.7% of the total bacterial genera identified. Our results have demonstrated that there is a wide assortment of bacterial genera present in dental unit waterlines.
Collapse
Affiliation(s)
- Hye Young Yoon
- Department of Oral Microbiology, College of Dentistry, Research Institute of Oral Science, Gangneung-Wonju National University
| | - Si Young Lee
- Department of Oral Microbiology, College of Dentistry, Research Institute of Oral Science, Gangneung-Wonju National University
| |
Collapse
|
9
|
Zeinali T, Bozorgvar E, Habibi M, Akbari N, Barikbin B. Suction Hoses of Dental Units as a Potential Source of Microbial Contamination. Oman Med J 2020; 35:e107. [PMID: 32181009 PMCID: PMC7073387 DOI: 10.5001/omj.2020.25] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2019] [Accepted: 06/02/2019] [Indexed: 11/21/2022] Open
Abstract
Objectives Dental units are necessary tools for modern dentistry. Microbial contamination of dental units is thought to be the result of biofilm formation in various parts of the unit. We aimed to identify the total microbial count in the suction hose of dental units, and detect the presence of Pseudomonas aeruginosa. Methods Random sampling of suction hoses of dental units in Birjand, Iran, was performed in dental clinics on the first (n = 115) and last (n = 115) working days of the week. Total viable counts of bacteria and detection of P. aeruginosa were performed on plate count agar and cetrimide agar, respectively. Plates were incubated at 37 °C for 48 hours. Results None of the samples were free from bacterial contamination. P. aeruginosa was detected in 22.6% and 18.3% of samples taken on the first and last working days, respectively. Conclusions Suction hoses were heavily contaminated with bacteria, especially opportunistic pathogens, and current disinfection does not adequately control the contamination.
Collapse
Affiliation(s)
- Tayebeh Zeinali
- Infectious Diseases Research Center, Department of Public Health, School of Health, Birjand University of Medical Sciences, Birjand, Iran
| | - Elham Bozorgvar
- Student Research Committee, Birjand University of Medical Sciences, Birjand, Iran
| | - Moghgan Habibi
- Student Research Committee, Birjand University of Medical Sciences, Birjand, Iran
| | - Narjes Akbari
- School of Dentistry, Birjand University of Medical Sciences, Birjand, Iran
| | - Behnam Barikbin
- Social Determinants of Health Research Center, Department of Environmental Health Engineering, School of Health, Birjand University of Medical Sciences, Birjand, Iran
| |
Collapse
|
10
|
Ji XY, Fei CN, Zhang Y, Liu J, Liu H, Song J. Three key factors influencing the bacterial contamination of dental unit waterlines: a 6-year survey from 2012 to 2017. Int Dent J 2018; 69:192-199. [PMID: 30565215 DOI: 10.1111/idj.12456] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
BACKGROUND The contaminated output water from dental unit waterlines (DUWLs) is a potential risk to both patients and dental personnel who are frequently exposed to this water or aerosols. AIM The purpose was to evaluate the contamination level and prevalence of bacteria in the output water of DUWLs, and to identify key factors to provide technical support for formulating relevant policies. METHODS We developed a special sampling connector designed for collecting dental handpiece output water and a measurement device to assess retraction of a dental chair unit (DCU). Output water from dental handpieces and air/water syringes were collected as representative of DUWLs. Water samples were tested with reference to China's national standard. FINDINGS From 2012 to 2017, 318 DCUs were randomly selected from 64 hospitals in Tianjin, China. Of these DCUs, 78.93% had no disinfection to prevent DUWL contamination. Three-hundred and forty-three (56.14%) samples complied with the guidelines on DUWL output water. The highest concentration of bacteria was 1.8 × 106 colony-forming units (CFUs)/mL. The three key factors of influence were as follows: daily or weekly disinfection of DUWLs; water supply source being hospital self-made purified water or purchased purified bottled water; and DCU with a valid anti-retraction valve. Potential infectious agents, including Bacillus cereus, Burkholderia cepacia and Pseudomonas aeruginosa, were isolated. CONCLUSION There was a high rate of contamination in DUWLs. This highlights the need to develop national standards. There is a need to disinfect the DUWLs periodically and use a cleaner source of water; more attention should be paid to the efficacy of DCU anti-retraction valves.
Collapse
Affiliation(s)
- Xue-Yue Ji
- Department of Infectious Disease, Tianjin Centers for Disease Control and Prevention, Tianjin, China
| | - Chun-Nan Fei
- Department of Infectious Disease, Tianjin Centers for Disease Control and Prevention, Tianjin, China
| | - Ying Zhang
- Department of Infectious Disease, Tianjin Centers for Disease Control and Prevention, Tianjin, China
| | - Jun Liu
- Department of Infectious Disease, Tianjin Centers for Disease Control and Prevention, Tianjin, China
| | - He Liu
- Department of Infectious Disease, Tianjin Centers for Disease Control and Prevention, Tianjin, China
| | - Jia Song
- Department of Infectious Disease, Tianjin Centers for Disease Control and Prevention, Tianjin, China
| |
Collapse
|
11
|
[Not Available]. Orthod Fr 2016; 87:119-49. [PMID: 27083237 DOI: 10.1051/orthodfr/2016002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
12
|
Pseudomonas aeruginosa and Achromobacter sp. clonal selection leads to successive waves of contamination of water in dental care units. Appl Environ Microbiol 2015; 81:7509-24. [PMID: 26296724 DOI: 10.1128/aem.01279-15] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2015] [Accepted: 08/12/2015] [Indexed: 01/30/2023] Open
Abstract
Dental care unit waterlines (DCUWs) consist of complex networks of thin tubes that facilitate the formation of microbial biofilms. Due to the predilection toward a wet environment, strong adhesion, biofilm formation, and resistance to biocides, Pseudomonas aeruginosa, a major human opportunistic pathogen, is adapted to DCUW colonization. Other nonfermentative Gram-negative bacilli, such as members of the genus Achromobacter, are emerging pathogens found in water networks. We reported the 6.5-year dynamics of bacterial contamination of waterlines in a dental health care center with 61 dental care units (DCUs) connected to the same water supply system. The conditions allowed the selection and the emergence of clones of Achromobacter sp. and P. aeruginosa characterized by multilocus sequence typing, multiplex repetitive elements-based PCR, and restriction fragment length polymorphism in pulsed-field gel electrophoresis, biofilm formation, and antimicrobial susceptibility. One clone of P. aeruginosa and 2 clones of Achromobacter sp. colonized successively all of the DCUWs: the last colonization by P. aeruginosa ST309 led to the closing of the dental care center. Successive dominance of species and clones was linked to biocide treatments. Achromobacter strains were weak biofilm producers compared to P. aeruginosa ST309, but the coculture of P. aeruginosa and Achromobacter enhanced P. aeruginosa ST309 biofilm formation. Intraclonal genomic microevolution was observed in the isolates of P. aeruginosa ST309 collected chronologically and in Achromobacter sp. clone A. The contamination control was achieved by a complete reorganization of the dental health care center by removing the connecting tubes between DCUs.
Collapse
|
13
|
Güngör ND, Kadaifçiler DG, Peker OÖ. Investigation of the bacterial load and antibiotic susceptibility of dental units. ENVIRONMENTAL MONITORING AND ASSESSMENT 2014; 186:1847-1853. [PMID: 24197558 DOI: 10.1007/s10661-013-3498-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2013] [Accepted: 10/23/2013] [Indexed: 06/02/2023]
Abstract
The aim of this study was to evaluate the bacterial contamination level and to determine the antibiotic susceptibility of the isolated bacteria from dental unit waterlines (DUWLs) in Istanbul. Bacterial quality of DUWLs is very important, as patients and dental staff are regularly exposed to water and aerosols generated by the unit. If opportunistic pathogens such as Staphylococcus aureus, Pseudomonas aeruginosa, and Legionella pneumophila are present in DUWLs, patient and dental staff can be infected. One hundred water samples were collected from high-speed drills and input waters from 50 dental units. Aerobic heterotrophic bacteria counts and the presence of Legionella, Pseudomonas, oral streptococci, and Staphylococcus were investigated in dental unit waters and aerosol samples. In addition, the antibiotic susceptibility of the isolated and identified bacteria from DUWLs was examined. This research found that 37 out of 50 dental unit water samples exceeded the American Dental Association's limit of 200 colony-forming units (CFU)/mL(-1). Legionella, oral streptococci, and S. aureus were not detected in any water or aerosol samples, but P. aeruginosa was isolated in three DUWLs. Also, Pseudomonas and Staphylococcus were found in water and aerosol samples. Cefoperazone, ofloxacin, gentamicin, ciprofloxacin, and piperacillin were the most effective antibiotics against the isolated bacteria from DUWLs.
Collapse
Affiliation(s)
- Nihal Dogruöz Güngör
- Department of Biology, Faculty of Science, Istanbul University, 34134, Vezneciler, Istanbul, Turkey,
| | | | | |
Collapse
|
14
|
Fischer S, Meyer G, Kramer A. Economic comparison of conventional maintenance and electrochemical oxidation to warrant water safety in dental unit water lines. GMS KRANKENHAUSHYGIENE INTERDISZIPLINAR 2012; 7:Doc08. [PMID: 22558042 PMCID: PMC3334949 DOI: 10.3205/dgkh000192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND In preparation for implementation of a central water processing system at a dental department, we analyzed the costs of conventional decentralized disinfection of dental units against a central water treatment concept based on electrochemical disinfection. METHODS The cost evaluation included only the costs of annually required antimicrobial consumables and additional water usage of a decentralize conventional maintenance system for dental water lines build in the respective dental units and the central electrochemical water disinfection system, BLUE SAFETY™ Technologies. RESULTS In total, analysis of costs of 6 dental departments reviled additional annual costs for hygienic preventive measures of € 4,448.37. For the BLUE SAFETY™ Technology, the additional annual total agent consumption costs were € 2.18, accounting for approximately 0.05% of the annual total agent consumption costs of the conventional maintenance system. For both water processing concepts, the additional costs for energy could not be calculated, since the required data was not obtainable from the manufacturers. DISCUSSION For both concepts, the investment and maintenance costs were not calculated due to lack of manufacturer's data. Therefore, the results indicate the difference of costs for the required consumables only. Aside of the significantly lower annual costs for required consumables and disinfectants; a second advantage for the BLUE SAFETY™ Technology is its constant and automatic operation, which does not require additional staff resources. This not only safety human resources, but add additionally to cost saving. CONCLUSION Since the antimicrobial disinfection capacity of the BLUE SAFETY™ was demonstrated previously and is well known, this technology, which is comparable or even superior in its non-corrosive effect, may be regarded as method of choice for continuous disinfection and prevention of biofilm formation in dental units' water lines.
Collapse
Affiliation(s)
- Sebastian Fischer
- Institute of Hygiene and Environmental Medicine Greifswald, University Medicine, Greifswald, Germany
| | - Georg Meyer
- Center of Dentistry, Oral Medicine and Maxillofacial Surgery, University Medicine, Greifswald, Germany
| | - Axel Kramer
- Institute of Hygiene and Environmental Medicine Greifswald, University Medicine, Greifswald, Germany,*To whom correspondence should be addressed: Axel Kramer, Institute of Hygiene and Environmental Medicine Greifswald, University Medicine, Walther-Rathenau-Str. 49a, D- 17489 Greifswald, Germany, Phone: +49-3834-515542 Fax: +49-3834-515541, E-mail:
| |
Collapse
|
15
|
Pasquarella C, Veronesi L, Napoli C, Castiglia P, Liguori G, Rizzetto R, Torre I, Righi E, Farruggia P, Tesauro M, Torregrossa MV, Montagna MT, Colucci ME, Gallè F, Masia MD, Strohmenger L, Bergomi M, Tinteri C, Panico M, Pennino F, Cannova L, Tanzi M. Microbial environmental contamination in Italian dental clinics: A multicenter study yielding recommendations for standardized sampling methods and threshold values. THE SCIENCE OF THE TOTAL ENVIRONMENT 2012; 420:289-299. [PMID: 22335883 DOI: 10.1016/j.scitotenv.2012.01.030] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/28/2011] [Revised: 01/06/2012] [Accepted: 01/12/2012] [Indexed: 05/31/2023]
Abstract
A microbiological environmental investigation was carried out in ten dental clinics in Italy. Microbial contamination of water, air and surfaces was assessed in each clinic during the five working days, for one week per month, for a three-month period. Water and surfaces were sampled before and after clinical activity; air was sampled before, after, and during clinical activity. A wide variation was found in microbial environmental contamination, both within the participating clinics and for the different sampling times. Before clinical activity, microbial water contamination in tap water reached 51,200cfu/mL (colony forming units per milliliter), and that in Dental Unit Water Systems (DUWSs) reached 872,000cfu/mL. After clinical activity, there was a significant decrease in the Total Viable Count (TVC) in tap water and in DUWSs. Pseudomonas aeruginosa was found in 2.38% (7/294) of tap water samples and in 20.06% (59/294) of DUWS samples; Legionella spp. was found in 29.96% (89/297) of tap water samples and 15.82% (47/297) of DUWS samples, with no significant difference between pre- and post-clinical activity. Microbial air contamination was highest during dental treatments, and decreased significantly at the end of the working activity (p<0.05). The microbial buildup on surfaces increased significantly during the working hours. This study provides data for the establishment of standardized sampling methods, and threshold values for contamination monitoring in dentistry. Some very critical situations have been observed which require urgent intervention. Furthermore, the study emphasizes the need for research aimed at defining effective managing strategies for dental clinics.
Collapse
Affiliation(s)
- Cesira Pasquarella
- Dipartimento di Sanità Pubblica, Università degli Studi di Parma, Italy.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Growth and identification of bacteria in N-halamine dental unit waterline tubing using an ultrapure water source. Int J Microbiol 2011; 2011:767314. [PMID: 22220171 PMCID: PMC3246724 DOI: 10.1155/2011/767314] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2011] [Revised: 09/15/2011] [Accepted: 09/19/2011] [Indexed: 11/18/2022] Open
Abstract
This study examined bacterial growth and type on biofilm-controlling dental unit waterline (DUWL) tubing (T) and control manufacturer's tubing (C) in a laboratory DUWL model using ultrapure source water that was cycled through the lines. Sections of tubing lines were detached and examined for biofilm growth using SEM imaging at six sampling periods. Bacteria from inside surfaces of T and C, source unit, and reservoir were cultured and enumerated. At six months, organisms were molecularly identified from the alignment matches obtained from the top three BLAST searches for the 16S region. There was a 1–3 log increase in organism growth in a clean, nonsterile reservoir within an hour. Biofilm was established on the inside surfaces of C within three weeks, but not on T. Proteobacteria, and Sphingomonas spp. were identified in the source reservoir and C line, and a variation of the genera was found in T line.
Collapse
|
17
|
O’Donnell MJ, Boyle MA, Russell RJ, Coleman DC. Management of dental unit waterline biofilms in the 21st century. Future Microbiol 2011; 6:1209-26. [DOI: 10.2217/fmb.11.104] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
Abstract
Dental chair units (DCUs) use water to cool and irrigate DCU-supplied instruments and tooth surfaces, and provide rinsewater during dental treatment. A complex network of interconnected plastic dental unit waterlines (DUWLs) supply water to these instruments. DUWLs are universally prone to microbial biofilm contamination seeded predominantly from microorganisms in supply water. Consequently, DUWL output water invariably becomes contaminated by high densities of microorganisms, principally Gram-negative environmental bacteria including Pseudomonas aeruginosa and Legionella species, but sometimes contain human-derived pathogens such as Staphylococcus aureus. Patients and staff are exposed to microorganisms from DUWL output water and to contaminated aerosols generated by DCU instruments. A wide variety of approaches, many unsuccessful, have been proposed to control DUWL biofilm. More recently, advances in biofilm science, chemical DUWL biofilm treatment agents, DCU design, supply water treatment and development of automated DUWL biofilm control systems have provided effective long-term solutions to DUWL biofilm control.
Collapse
Affiliation(s)
- Mary J O’Donnell
- Microbiology Research Unit, Division of Oral Biosciences, Dublin Dental University Hospital, University of Dublin, Trinity College Dublin, Dublin 2, Republic of Ireland
| | - Maria A Boyle
- Microbiology Research Unit, Division of Oral Biosciences, Dublin Dental University Hospital, University of Dublin, Trinity College Dublin, Dublin 2, Republic of Ireland
| | - Ronnie J Russell
- The Department of Microbiology, The Moyne Institute of Preventive Medicine, University of Dublin, Trinity College Dublin, Dublin 2, Republic of Ireland
| | | |
Collapse
|
18
|
D'Ovidio C, Carnevale A, Pantaleone G, Piattelli A, Di Bonaventura G. First report of an acute purulent maxillary sinusitis caused by Pseudomonas aeruginosa secondary to dental implant placement in an immunocompetent patient. Br Dent J 2011; 211:205-7. [PMID: 21904351 DOI: 10.1038/sj.bdj.2011.723] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/21/2011] [Indexed: 11/09/2022]
Abstract
STUDY DESIGN In this case report, we present maxillary Pseudomonas aeruginosa sinusitis in an immunocompetent patient who underwent an autologous bone transplant for the insertion of dental implants. RESULTS The infection was eradicated after removal of the dental implants and long-term antibiotic therapy. CONCLUSION Despite the infection resolution, severe complications were observed with important legal consequences.
Collapse
Affiliation(s)
- C D'Ovidio
- Department of Medicine and Aging Science, Section of Legal Medicine, 'G. d'Annunzio' University of Chieti-Pescara, Italy.
| | | | | | | | | |
Collapse
|
19
|
Orrù G, Del Nero S, Tuveri E, Laura Ciusa M, Pilia F, Erriu M, Orrù G, Liciardi M, Piras V, Denotti G. Evaluation of antimicrobial-antibiofilm activity of a hydrogen peroxide decontaminating system used in dental unit water lines. Open Dent J 2010; 4:140-6. [PMID: 21113279 PMCID: PMC2948419 DOI: 10.2174/1874210601004010140] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2009] [Revised: 02/15/2010] [Accepted: 02/25/2010] [Indexed: 11/22/2022] Open
Abstract
A dental unit water line (DUWL) equipped with a device designed to automatically and continually flush a bacteriostatic solution of hydrogen peroxide (WHE) and a discontinuous disinfecting system (BIOSTER) was evaluated. In the first instance a preliminary sensitivity test on a large number of microorganisms (bacteria and fungi) was tried with a H2O2 range from 100 to 800 ppm. The bacteria frequently reported in DUWL (including Pseudomonas spp, Streptococcus spp., Staphylococcus spp., E. coli) and some periodontal pathogens showed a minimum inhibitory concentration from 100 to 300 H2O2 ppm (also including M. marinum and C. albicans). However, H2O2 did not show any inhibitory effects against: A. actinomycetemcomitans, C. glabrata C. parapsilos, F. nucleatum, M. micros. In a second step, the DUWL was experimentally infected with S. faecalis, E. coli, P. aeruginosa, S. aureus. After disinfection steps with 3% H2O2, the inhibitory effect on planktonic forms and on sessile biofilm was measured. In a third step, the count of 16S rRNA gene copies by real time PCR at different points of the DUWL described an accrue of bacterial slime in “hot spot” regions characterized by irregular/slow water flux (valves, elbows). However these results suggest that hydrogen peroxide is not only able to inhibit bursts of planktonic bacteria inside the DUWL, but that it could also be effective against sessile biofilm containing heterotrophic microorganisms derived from domestic water line contamination. In addition some oral pathogens could be contaminating and surviving in DUWL.
Collapse
Affiliation(s)
- Germano Orrù
- OBL (Oral Biotechnology Laboratory), Dipartimento di Chirurgia e Scienze Odontostomatologiche, Universita' degli Studi di Cagliari, Cagliari, Italy
| | | | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Two cases of Pseudomonas aeruginosa epidural abscesses and cervical osteomyelitis after dental extractions. Spine (Phila Pa 1976) 2008; 33:E293-6. [PMID: 18427310 DOI: 10.1097/brs.0b013e31816c9120] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN Case report. OBJECTIVES To report 2 unusual cases of Pseudomonas aeruginosa epidural abscesses and cervical osteomyelitis after routine dental extractions and to review relevant literature. SUMMARY OF BACKGROUND DATA Pseudomonas aeruginosa is a rare cause of cervical osteomyelitis in patients after dental extractions. Only 1 prior case could be found in the literature. METHODS The cases of an 18-year-old male and a 23-year-old female are presented. PubMed was used to search for relevant literature. RESULTS Our 2 patients presented with excruciating neck pain within 24 hours of routine dental extractions and, by imaging were found to have cervical epidural abscesses and osteomyelitis. Both patients were taken to the operating room for drainage and corpectomy and treated with prolonged courses of intravenous antibiotics. When seen in follow up 3 months later, neither patient demonstrated any neurologic sequelae. CONCLUSION Pseudomonas aeruginosa epidural abscesses and osteomyelitis of the cervical spine have only rarely been reported in healthy patients after dental extractions. To our knowledge, the 2 patients reported here are only the second 2 such cases reported in the literature. Unfortunately, as in prior cases, these 2 patients had a significant delay in diagnosis. Therefore, a strong suspicion must be maintained for all patients presenting with neck pain after a recent dental extraction and appropriate imaging must be obtained urgently.
Collapse
|
21
|
. DT, . PG, . KG, . SG. Prevalence of Pseudomonas aeruginosa in Dental Unit Water-Lines. ACTA ACUST UNITED AC 2007. [DOI: 10.3923/jm.2007.983.987] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|