1
|
Zoghbi WA, Jone PN, Chamsi-Pasha MA, Chen T, Collins KA, Desai MY, Grayburn P, Groves DW, Hahn RT, Little SH, Kruse E, Sanborn D, Shah SB, Sugeng L, Swaminathan M, Thaden J, Thavendiranathan P, Tsang W, Weir-McCall JR, Gill E. Guidelines for the Evaluation of Prosthetic Valve Function With Cardiovascular Imaging: A Report From the American Society of Echocardiography Developed in Collaboration With the Society for Cardiovascular Magnetic Resonance and the Society of Cardiovascular Computed Tomography. J Am Soc Echocardiogr 2024; 37:2-63. [PMID: 38182282 DOI: 10.1016/j.echo.2023.10.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/07/2024]
Abstract
In patients with significant cardiac valvular disease, intervention with either valve repair or valve replacement may be inevitable. Although valve repair is frequently performed, especially for mitral and tricuspid regurgitation, valve replacement remains common, particularly in adults. Diagnostic methods are often needed to assess the function of the prosthesis. Echocardiography is the first-line method for noninvasive evaluation of prosthetic valve function. The transthoracic approach is complemented with two-dimensional and three-dimensional transesophageal echocardiography for further refinement of valve morphology and function when needed. More recently, advances in computed tomography and cardiac magnetic resonance have enhanced their roles in evaluating valvular heart disease. This document offers a review of the echocardiographic techniques used and provides recommendations and general guidelines for evaluation of prosthetic valve function on the basis of the scientific literature and consensus of a panel of experts. This guideline discusses the role of advanced imaging with transesophageal echocardiography, cardiac computed tomography, and cardiac magnetic resonance in evaluating prosthetic valve structure, function, and regurgitation. It replaces the 2009 American Society of Echocardiography guideline on prosthetic valves and complements the 2019 guideline on the evaluation of valvular regurgitation after percutaneous valve repair or replacement.
Collapse
Affiliation(s)
- William A Zoghbi
- Houston Methodist Hospital, DeBakey Heart & Vascular Center, Houston, Texas.
| | - Pei-Ni Jone
- Lurie Children's Hospital, Northwestern University, Chicago, Illinois
| | | | - Tiffany Chen
- Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | | | - Milind Y Desai
- Heart and Vascular Institute, Cleveland Clinic, Cleveland, Ohio
| | - Paul Grayburn
- Baylor Scott & White Health, University of Texas Southwestern, Dallas, Texas
| | - Daniel W Groves
- University of Colorado Anschutz Medical Campus, Aurora, Colorado
| | - Rebecca T Hahn
- Columbia University Irving Medical Center, New York, New York
| | - Stephen H Little
- Houston Methodist Hospital, DeBakey Heart & Vascular Center, Houston, Texas
| | - Eric Kruse
- University of Chicago Medical Center, Chicago, Illinois
| | | | - Sangeeta B Shah
- VCU Pauley Heart Center, Virginia Commonwealth University, Richmond, Virginia
| | - Lissa Sugeng
- North Shore University Hospital, Manhasset, New York
| | - Madhav Swaminathan
- Cardiothoracic Anesthesiology and Critical Care Medicine, Duke University, Durham, North Carolina
| | | | | | - Wendy Tsang
- University of Toronto, Toronto, Ontario, Canada
| | | | - Edward Gill
- University of Colorado School of Medicine, Aurora, Colorado
| |
Collapse
|
2
|
Shojaeifard M, Daryanavard A, Karimi Behnagh A, Moradian M, Erami S, Dehghani Mohammad Abadi H. Assessment of normal hemodynamic profile of mechanical pulmonary prosthesis by doppler echocardiography: a prospective cross-sectional study. Cardiovasc Ultrasound 2020; 18:14. [PMID: 32414369 PMCID: PMC7229630 DOI: 10.1186/s12947-020-00196-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2020] [Accepted: 05/06/2020] [Indexed: 12/05/2022] Open
Abstract
Objectives Very few reports have described the Doppler-derived echocardiographic parameters for mechanical pulmonary valve prosthesis (MPVP). This study aims to describe the normal Doppler hemodynamic profile of MPVP using Doppler echocardiography. Methods The current prospective, single center observational study enrolled 108 patients who underwent pulmonary valve replacement (PVR) surgery for the first time and had a normally functioning prosthesis post-operation. The hemodynamic performance of MPVPs, considering flow dependent and flow independent parameters, was evaluated at two follow-up points, at week one and week four post-operation. All assessments were conducted by an experienced echocardiographer. Results The mean age (±SD) of the participants was 26.4 (±8.98). Tetralogy of Fallot (ToF) was the most common underlying disease leading to PVR, with a prevalence of 88%. At first week post-operation, measurement of indices reported the following values (±SD): peak pressure gradient (PPG): 18.51(±7.64) mm Hg; mean pressure gradient (MPG): 10.88(±5.62) mm Hg; peak velocity (PV): 1.97(±0.43)m/s; doppler velocity index (DVI): 0.61(±18); pulmonary velocity acceleration time (PVAT): 87.35(±15.16) ms; effective orifice area (EOA): 2.98(±1.02) cm2;and effective orifice area to body surface area ratio (EOA/ BSA): 1.81(±0.62) cm2/m2. Comparing these measurements with those obtained from the second follow-up (at week four post-op) failed to hold significant difference in all values except for PVAT, which had increased from its primary value (p = 0.038). Also, right ventricular (RV) function showed significant improvement throughout the follow up period. Conclusion The findings of this study help strengthen the previously scarce data pool and better establish the normal values for Doppler hemodynamics in mechanical pulmonary prosthesis.
Collapse
Affiliation(s)
- Maryam Shojaeifard
- Echocardiography Research Center, Rajaie Cardiovascular, Medical, and Research Center, Iran University of Medical Sciences, Tehran, Iran
| | - Ali Daryanavard
- Echocardiography Research Center, Rajaie Cardiovascular, Medical, and Research Center, Iran University of Medical Sciences, Tehran, Iran
| | - Arman Karimi Behnagh
- Echocardiography Research Center, Rajaie Cardiovascular, Medical, and Research Center, Iran University of Medical Sciences, Tehran, Iran.
| | - Maryam Moradian
- Rajaie Cardiovascular, Medical, and Research center, Iran university of medical sciences, Tehran, Iran
| | - Sajjad Erami
- Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| | | |
Collapse
|
3
|
Sadeghpour A, Kyavar M, Javani B, Bakhshandeh H, Maleki M, Khajali Z, Subrahmanyan L. Mid-term outcome of mechanical pulmonary valve prostheses: the importance of anticoagulation. J Cardiovasc Thorac Res 2014; 6:163-8. [PMID: 25320663 PMCID: PMC4195966 DOI: 10.15171/jcvtr.2014.005] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2014] [Accepted: 09/02/2014] [Indexed: 11/09/2022] Open
Abstract
INTRODUCTION Pulmonary valve replacement (PVR) is being performed more commonly late after the correction of tetralogy of Fallot. Most valves are replaced with an allograft or xenograft, although reoperations are a common theme. Mechanical prostheses have a less favorable reputation due to the necessity of lifelong anticoagulation therapy and higher risk of thrombosis, but they are also less likely to require reoperation. There is a paucity of data on the use of prosthetic valves in the pulmonary position. We report the midterm outcomes of 38 cases of PVR with mechanical prostheses. METHODS One hundred twenty two patients who underwent PVR were studied. Thirty-eight patients, mean age 25 ± 8.4 years underwent PVR with mechanical prostheses based on the right ventricular function and the preferences of the patients and physicians. Median age of prosthesis was 1 year (range 3 months to 5 years). RESULTS Seven (18%) patients had malfunctioning pulmonary prostheses and two patients underwent redo PVR. Mean International Normalized Ratio (INR) in these seven patients was 2.1±0.8. Fibrinolytic therapy was tried and five of them responded to it well. There was no significant association between the severity of right ventricular dysfunction, patient's age, prostheses valve size and age of the prosthesis in the patients with prosthesis malfunction. CONCLUSION PVR with mechanical prostheses can be performed with promising midterm outcomes. Thrombosis on mechanical pulmonary valve prostheses remains a serious complication, but most prosthesis malfunction respond to fibrinolytic therapy, underscoring the need for adequate anticoagulation therapy.
Collapse
Affiliation(s)
- Anita Sadeghpour
- Rajaie Cardiovascular, Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran
| | - Majid Kyavar
- Rajaie Cardiovascular, Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran
| | - Bahareh Javani
- Rajaie Cardiovascular, Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran
| | - Hooman Bakhshandeh
- Rajaie Cardiovascular, Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran
| | - Majid Maleki
- Rajaie Cardiovascular, Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran
| | - Zahra Khajali
- Rajaie Cardiovascular, Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran
| | - Lakshman Subrahmanyan
- Section of Cardiology, Department of Medicine, Yale University School of Medicine, New Haven, Connecticut, USA
| |
Collapse
|
4
|
Pulmonary valve replacement with mechanical prosthesis: long-term results in 4 patients. Ann Thorac Surg 2010; 89:2036-8. [PMID: 20494083 DOI: 10.1016/j.athoracsur.2009.10.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/18/2009] [Revised: 09/22/2009] [Accepted: 10/08/2009] [Indexed: 11/21/2022]
Abstract
Pulmonary valve replacement is rarely performed and is usually done with biological prostheses or grafts. The use of mechanical prostheses is still a debated issue. We analyzed the outcome of 4 patients at 11 years after pulmonary valve replacement with a mechanical prosthesis. During follow-up, all patients remained asymptomatic, with no arrhythmias and good anticoagulation. An echocardiogram showed preserved ventricular contraction and normal function of the prostheses, with low pressure gradients. No infective endocarditis occurred. Mechanical prostheses appear to be a good choice for pulmonary valve replacement. Surgical and clinical results were satisfactory with no complications, acceptable pressure gradients, and good ventricular function after more than 10 years. Lifelong anticoagulation is mandatory, but this is usually well tolerated.
Collapse
|