Feng W, Chen Y, Han Y, Diao Z, Zhao Z, Zhang Y, Huang T, Ma Y, Li Z, Jiang J, Li J, Li J, Zhang R. Key performance evaluation of commercialized multiplex rRT-PCR kits for respiratory viruses: implications for application and optimization. Microbiol Spectr 2024; 12:e0164124. [PMID: 39470276 PMCID: PMC11619282 DOI: 10.1128/spectrum.01641-24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2024] [Accepted: 10/06/2024] [Indexed: 10/30/2024] Open
Abstract
Respiratory tract infections (RTIs) caused by viruses are prevalent and significant conditions in clinical settings. Accurate and effective detection is of paramount importance in the diagnosis, treatment, and prevention of viral RTIs. With technological advancements, multiplex real-time reverse transcription polymerase chain reaction (rRT-PCR) assays have been developed and extensively adopted for the diagnosis of viral RTIs. Given the potential challenges in the detection performance of multiplex assays, this study evaluated the analytical sensitivity and competitive interference of the six most commonly used multiplex rRT-PCR kits for detection of respiratory viruses in China. The results revealed that the limits of detection were variable across the viruses and kits. Most of the evaluated multiplex kits demonstrated comparable or enhanced analytical sensitivity compared with singleplex kits for clinically significant viruses, including human adenovirus (HAdV)-3, HAdV-7, Omicron BA.5, H1N1pdm09, H3N2, B/Victoria, respiratory syncytial virus subtype A, and respiratory syncytial virus subtype B, whereas multiplex kits showed relatively less analytical sensitivity for human rhinovirus-B72, human metapneumovirus-A2, parainfluenza virus (PIV)-1, and PIV-3. In addition, most multiplex kits successfully identified co-infections when one analyte was present at a low concentration and another analyte was present at a high concentration. IMPORTANCE The complexity and severity of viral respiratory tract infections (RTIs) emphasize the pivotal role of precise diagnosis for viral RTIs in guiding effective public health responses and ensuring appropriate medical interventions, given the substantial population at risk. This study highlights the necessity and importance of evaluating the analytical validity of multiplex real-time reverse transcription polymerase chain reaction assays, offering valuable insights into their optimization and application.
Collapse
Affiliation(s)
- Wanyu Feng
- National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing, China
- National Center for Clinical Laboratories, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, China
| | - Yuqing Chen
- National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing, China
- National Center for Clinical Laboratories, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, China
| | - Yanxi Han
- National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing, China
- National Center for Clinical Laboratories, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, China
| | - Zhenli Diao
- National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing, China
- National Center for Clinical Laboratories, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, China
| | - Zihong Zhao
- National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing, China
- Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, China
| | - Yuanfeng Zhang
- National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing, China
- National Center for Clinical Laboratories, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, China
| | - Tao Huang
- National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing, China
- National Center for Clinical Laboratories, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, China
| | - Yu Ma
- National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing, China
- National Center for Clinical Laboratories, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, China
| | - Ziqiang Li
- National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing, China
- National Center for Clinical Laboratories, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, China
| | - Jian Jiang
- National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing, China
- National Center for Clinical Laboratories, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, China
| | - Jing Li
- National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing, China
- National Center for Clinical Laboratories, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, China
| | - Jinming Li
- National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing, China
- National Center for Clinical Laboratories, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, China
| | - Rui Zhang
- National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing, China
- National Center for Clinical Laboratories, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, China
| |
Collapse
|
2
|
Matic N, Lawson T, Ritchie G, Lowe CF, Romney MG. Testing the limits of multiplex respiratory virus assays for SARS-CoV-2 at high cycle threshold values: Comparative performance of cobas 6800/8800 SARS-CoV-2 & Influenza A/B, Xpert Xpress SARS-CoV-2/Flu/RSV, and cobas Liat SARS-CoV-2 & Influenza A/B. JOURNAL OF THE ASSOCIATION OF MEDICAL MICROBIOLOGY AND INFECTIOUS DISEASE CANADA = JOURNAL OFFICIEL DE L'ASSOCIATION POUR LA MICROBIOLOGIE MEDICALE ET L'INFECTIOLOGIE CANADA 2024; 8:328-335. [PMID: 38250621 PMCID: PMC10797767 DOI: 10.3138/jammi-2022-0039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 03/21/2023] [Accepted: 03/26/2023] [Indexed: 01/23/2024]
Abstract
Background Multiplex real-time RT-PCR assays for respiratory pathogens are valuable tools to optimize laboratory workflow and turnaround time. At a time when resurgence of influenza and respiratory syncytial virus (RSV) cases have been widely observed along with continued transmission of SARS-CoV-2, timely identification of all circulating respiratory viruses is crucial. This study evaluates the detection of low viral loads of SARS-CoV-2 by four multiplex molecular assays: Roche cobas 6800/8800 SARS-CoV-2 & Influenza A/B Test, Cepheid Xpert Xpress SARS-CoV-2/Flu/RSV, cobas Liat SARS-CoV-2 & Influenza A/B, and a laboratory-developed test (LDT). Methods Retrospective upper respiratory tract specimens positive for various respiratory viruses at a range of cycle threshold (Ct) values (18-40) were tested by four multiplex assays. Positive and negative percent agreement (PPA and NPA) with validated RT-PCR assays were calculated. Results A total of 82 samples were assessed, with discordant results observed in a portion of the samples (10/82, 12.2%) where Ct values were >33. The majority of the discordant results (6/10, 60%) were false negatives. Overall, PPA was 100% (58/58) for cobas 6800, 97.4% (38/39) for GeneXpert, 100% (17/17) for Liat, and 90.5% (57/63) for the LDT. PPA for the LDT increased to 92.1% after manual review of amplification curves. Conclusions Commercial multiplex respiratory virus assays have good performance for samples with medium to high viral loads (Ct values <33). Laboratories should consider appropriate test result review and confirmation protocols to optimize sensitivity, and may consider reporting samples with additional interpretive comments when low viral loads are detected.
Collapse
Affiliation(s)
- Nancy Matic
- Division of Medical Microbiology and Virology, St. Paul's Hospital, Vancouver, Canada
- Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, Canada
| | - Tanya Lawson
- Division of Medical Microbiology and Virology, St. Paul's Hospital, Vancouver, Canada
| | - Gordon Ritchie
- Division of Medical Microbiology and Virology, St. Paul's Hospital, Vancouver, Canada
- Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, Canada
| | - Christopher F Lowe
- Division of Medical Microbiology and Virology, St. Paul's Hospital, Vancouver, Canada
- Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, Canada
| | - Marc G Romney
- Division of Medical Microbiology and Virology, St. Paul's Hospital, Vancouver, Canada
- Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, Canada
| |
Collapse
|
3
|
Xie LM, Yin X, Xie TA, Su JW, Huang Q, Zhang JH, Huang YF, Guo XG. Meta-Analysis of the Diagnostic Efficacy of the Luminex xTAG Respiratory Viral Panel FAST v2 Assay for Respiratory Viral Infections. Yonsei Med J 2022; 63:95-103. [PMID: 34913289 PMCID: PMC8688366 DOI: 10.3349/ymj.2022.63.1.95] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 09/27/2021] [Accepted: 10/13/2021] [Indexed: 11/27/2022] Open
Abstract
PURPOSE Acute respiratory viral infections pose significant morbidity and mortality, making it essential to diagnose respiratory viral infections rapidly. In this study, the diagnostic efficacy of the Luminex xTAG Respiratory Virus Panel (RVP) FAST v2 test was evaluated on respiratory viral infections. MATERIALS AND METHODS Information was retrieved from electronic databases, including Embase, Web of Science, PubMed, and Cochrane Library, for systematic review. Studies that fulfilled predefined inclusion criteria were included. After the extraction of information, statistical software was utilized for quality evaluation, data analysis, and assessment of publication bias. RESULTS Eighty groups in fourfold tables from nine articles were included to perform statistical analyses. Therein, the mean specificity and mean sensitivity of Luminex xTAG RVP FAST v2 test for the detection of respiratory viral infections were 0.99 (0.98-0.99) and 0.88 (0.87-0.90), respectively. Additionally, the negative and positive likelihood ratios were 0.14 (0.11-0.19) and 87.42 (61.88-123.50), respectively. Moreover, the diagnostic odds ratio and area under the curve of summary receiver operating characteristic were 714.80 and 0.9886, respectively. CONCLUSION The Luminex xTAG RVP FAST v2 test could be a reliable and rapid diagnostic method for multiple respiratory viral infections.
Collapse
Affiliation(s)
- Li-Min Xie
- Department of Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
- Department of Clinical Medicine, The Third Clinical School of Guangzhou Medical University, Guangzhou, China
| | - Xin Yin
- Department of Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
- Department of Pediatrics, The Pediatrics School of Guangzhou Medical University, Guangzhou, China
| | - Tian-Ao Xie
- Department of Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
- Department of Clinical Medicine, The Third Clinical School of Guangzhou Medical University, Guangzhou, China
| | - Jian-Wen Su
- Department of Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
- Department of Clinical Medicine, The Third Clinical School of Guangzhou Medical University, Guangzhou, China
| | - Qin Huang
- Department of Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
- Department of Clinical Medicine, The Third Clinical School of Guangzhou Medical University, Guangzhou, China
| | - Jing-Hao Zhang
- Department of Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
- Department of Clinical Medicine, The Third Clinical School of Guangzhou Medical University, Guangzhou, China
| | - Yin-Fei Huang
- Department of Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
- Department of Clinical Medicine, The Third Clinical School of Guangzhou Medical University, Guangzhou, China
| | - Xu-Guang Guo
- Department of Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
- Department of Clinical Medicine, The Third Clinical School of Guangzhou Medical University, Guangzhou, China
- Key Laboratory for Major Obstetric Diseases of Guangdong Province, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
- Key Laboratory of Reproduction and Genetics of Guangdong Higher Education Institutes, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China.
| |
Collapse
|
4
|
Nakhaie M, Soleimanjahi H, Mollaie HR, Arabzadeh SMA. Development of Multiplex Reverse Transcription-Polymerase Chain Reaction for Simultaneous Detection of Influenza A, B and Adenoviruses. IRANIAN JOURNAL OF PATHOLOGY 2018; 13:54-62. [PMID: 29731796 PMCID: PMC5929389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/26/2016] [Accepted: 03/11/2017] [Indexed: 11/10/2022]
Abstract
BACKGROUND AND OBJECTIVE Millions of people in developing countries lose their lives due to acute respiratory infections, such as Influenza A & B and Adeno viruses. Given the importance of rapid identification of the virus, in this study the researchers attempted to design a method that enables detection of influenza A, B, and adenoviruses, quickly and simultaneously. The Multiplex RT PCR method was the preferred method for the detection of influenza A, B, and adenoviruses in clinical specimens because it is rapid, sensitive, specific, and more cost-effective than alternative methods. METHODS After collecting samples from patients with respiratory disease, virus genome was extracted, then Monoplex PCR was used on positive samples and Multiplex RT-PCR on clinical specimens. Finally, by comparing the bands of these samples, the type of virus in the clinical samples was determined. RESULTS Performing Multiplex RT-PCR on 50 samples of respiratory tract led to following results; flu A: 12.5%, fluB: 50%, adeno: 27.5%, negative: 7.5%, and 2.5% contamination. CONCLUSION Reverse transcription-multiplex Polymerase Chain Reaction (PCR) technique, a rapid diagnostic tool, has potential for high-throughput testing. This method has a significant advantage, which provides simultaneous amplification of numerous viruses in a single reaction. This study concentrates on multiplex molecular technologies and their clinical application for the detection and quantification of respiratory pathogens. The improvement in diagnostic testing for viral respiratory pathogens effects patient management, and leads to more cost-effective delivery of care. It limits unnecessary antibiotic use and improves clinical management by use of suitable treatment.
Collapse
Affiliation(s)
- Mohsen Nakhaie
- Dept. of Virology, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
| | - Hoorieh Soleimanjahi
- Dept. of Virology, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran,Corresponding information: Tarbiat Modares University, Jalal Ale Ahmad Highway, P.O. Box: 14115-111, Tehran, Iran,
Tel: (+98) 21 82883561, Fax: (+98) 21 82883561, E-mail:
| | - Hamid Reza Mollaie
- Dept. of Medical Microbiology, Kerman University of Medical Sciences, Kerman, Iran,Corresponding information: Tarbiat Modares University, Jalal Ale Ahmad Highway, P.O. Box: 14115-111, Tehran, Iran,
Tel: (+98) 21 82883561, Fax: (+98) 21 82883561, E-mail:
| | | |
Collapse
|
5
|
Abstract
Nucleic acid based diagnostic techniques are routinely used for the detection of infectious agents. Most of these assays rely on nucleic acid extraction platforms for the extraction and purification of nucleic acids and a separate real-time PCR platform for quantitative nucleic acid amplification tests (NATs). Several microfluidic lab on chip (LOC) technologies have been developed, where mechanical and chemical methods are used for the extraction and purification of nucleic acids. Microfluidic technologies have also been effectively utilized for chip based real-time PCR assays. However, there are few examples of microfluidic systems which have successfully integrated these two key processes. In this study, we have implemented an electro-actuation based LOC micro-device that leverages multi-frequency actuation of samples and reagents droplets for chip based nucleic acid extraction and real-time, reverse transcription (RT) PCR (qRT-PCR) amplification from clinical samples. Our prototype micro-device combines chemical lysis with electric field assisted isolation of nucleic acid in a four channel parallel processing scheme. Furthermore, a four channel parallel qRT-PCR amplification and detection assay is integrated to deliver the sample-to-detection NAT chip. The NAT chip combines dielectrophoresis and electrostatic/electrowetting actuation methods with resistive micro-heaters and temperature sensors to perform chip based integrated NATs. The two chip modules have been validated using different panels of clinical samples and their performance compared with standard platforms. This study has established that our integrated NAT chip system has a sensitivity and specificity comparable to that of the standard platforms while providing up to 10 fold reduction in sample/reagent volumes.
Collapse
|
6
|
Abstract
Acute upper and lower respiratory infections are a major public health problem and a leading cause of morbidity and mortality worldwide. At greatest risk are young children, the elderly, the chronically ill, and those with suppressed or compromised immune systems. Viruses are the predominant cause of respiratory tract illnesses and include RNA viruses such as respiratory syncytial virus, influenza virus, parainfluenza virus, metapneumovirus, rhinovirus, and coronavirus. Laboratory testing is required for a reliable diagnosis of viral respiratory infections, as a clinical diagnosis can be difficult since signs and symptoms are often overlapping and not specific for any one virus. Recent advances in technology have resulted in the development of newer diagnostic assays that offer great promise for rapid and accurate detection of respiratory viral infections. This chapter emphasizes the fundamental characteristics and clinical importance of the various RNA viruses that cause upper and lower respiratory tract diseases in the immunocompromised host. It highlights the laboratory methods that can be used to make a rapid and definitive diagnosis for the greatest impact on the care and management of ill patients, and the prevention and control of hospital-acquired infections and community outbreaks.
Collapse
|
7
|
Escuyer KL, Waters CL, Gowie DL, Maxted AM, Farrell GM, Fuschino ME, St. George K. The assessment of data sources for influenza virologic surveillance in New York State. Influenza Other Respir Viruses 2017; 11:138-147. [PMID: 27718314 PMCID: PMC5304574 DOI: 10.1111/irv.12433] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/04/2016] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND Following the 2013 USA release of the Influenza Virologic Surveillance Right Size Roadmap, the New York State Department of Health (NYSDOH) embarked on an evaluation of data sources for influenza virologic surveillance. OBJECTIVE To assess NYS data sources, additional to data generated by the state public health laboratory (PHL), which could enhance influenza surveillance at the state and national level. METHODS Potential sources of laboratory test data for influenza were analyzed for quantity and quality. Computer models, designed to assess sample sizes and the confidence of data for statistical representation of influenza activity, were used to compare PHL test data to results from clinical and commercial laboratories, reported between June 8, 2013 and May 31, 2014. RESULTS Sample sizes tested for influenza at the state PHL were sufficient for situational awareness surveillance with optimal confidence levels, only during peak weeks of the influenza season. Influenza data pooled from NYS PHLs and clinical laboratories generated optimal confidence levels for situational awareness throughout the influenza season. For novel influenza virus detection in NYS, combined real-time (rt) RT-PCR data from state and regional PHLs achieved ≥85% confidence during peak influenza activity, and ≥95% confidence for most of low season and all of off-season. CONCLUSIONS In NYS, combined data from clinical, commercial, and public health laboratories generated optimal influenza surveillance for situational awareness throughout the season. Statistical confidence for novel virus detection, which is reliant on only PHL data, was achieved for most of the year.
Collapse
Affiliation(s)
- Kay L. Escuyer
- Laboratory of Viral DiseasesWadsworth CenterNew York State Department of HealthAlbanyNYUSA
| | - Christine L. Waters
- Bureau of Communicable Disease ControlNew York State Department of HealthAlbanyNYUSA
| | - Donna L. Gowie
- Bureau of Communicable Disease ControlNew York State Department of HealthAlbanyNYUSA
| | - Angie M. Maxted
- Bureau of Communicable Disease ControlNew York State Department of HealthAlbanyNYUSA
| | - Gregory M. Farrell
- Laboratory of Viral DiseasesWadsworth CenterNew York State Department of HealthAlbanyNYUSA
| | - Meghan E. Fuschino
- Laboratory of Viral DiseasesWadsworth CenterNew York State Department of HealthAlbanyNYUSA
| | - Kirsten St. George
- Laboratory of Viral DiseasesWadsworth CenterNew York State Department of HealthAlbanyNYUSA
| |
Collapse
|
8
|
|
9
|
Leonard DG. Respiratory Infections. MOLECULAR PATHOLOGY IN CLINICAL PRACTICE 2016. [PMCID: PMC7123443 DOI: 10.1007/978-3-319-19674-9_52] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
The majority of respiratory tract infections (RTIs) are community acquired and are the single most common cause of physician office visits and among the most common causes of hospitalizations. The morbidity and mortality associated with RTIs are significant and the financial and social burden high due to lost time at work and school. The scope of clinical symptoms can significantly overlap among the respiratory pathogens, and the severity of disease can vary depending on patient age, underlying disease, and immune status, thereby leading to inaccurate presumptions about disease etiology. The rapid and accurate diagnosis of the causative agent of RTIs improves patient care, reduces morbidity and mortality, promotes effective hospital bed utilization and antibiotic stewardship, and reduces length of stay. This chapter focuses on the clinical utility, advantages, and disadvantages of viral and bacterial tests cleared by the Food and Drug Administration (FDA), and new promising technologies for the detection of bacterial agents of pneumonia currently in development or in US FDA clinical trials are briefly reviewed.
Collapse
Affiliation(s)
- Debra G.B. Leonard
- Pathology and Laboratory Medicine, University of Vermont College of Medicine and University of Vermont Medical Center, Burlington, Vermont USA
| |
Collapse
|
10
|
Chui L, Li V. Technical and Software Advances in Bacterial Pathogen Typing. METHODS IN MICROBIOLOGY 2015. [DOI: 10.1016/bs.mim.2015.06.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
11
|
Prakash R, Pabbaraju K, Wong S, Wong A, Tellier R, Kaler KVIS. Droplet Microfluidic Chip Based Nucleic Acid Amplification and Real-Time Detection of Influenza Viruses. JOURNAL OF THE ELECTROCHEMICAL SOCIETY 2014; 161:B3083-B3093. [PMID: 32287356 PMCID: PMC7105149 DOI: 10.1149/2.013402jes] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/14/2013] [Revised: 12/13/2013] [Indexed: 06/11/2023]
Abstract
Miniaturized bio-diagnostic devices have the potential to allow for rapid pathogen screening in clinical patient samples, as a low cost and portable alternative to conventional bench-top equipment. Miniaturization of key bio-diagnostic techniques, such as: nucleic acid detection and quantification, polymerase chain reaction (PCR), DNA fingerprinting, enzyme linked immunosorbent assay (ELISA), results in substantial reduction of reaction volumes (expensive samples/reagents) and shorter reaction times. Droplet microfluidics (DMF) is one of several miniaturized bio-sample handling techniques available for manipulating clinical samples and reagents in microliter (10-6 L) to picoliter (10-12 L) volume regime. Electro-actuation of sample and reagent in the form of droplets in the aforementioned volume regime, using dielectrophoresis (DEP) and/or Electrowetting (EW) are achieved by means of patterned, insulated metal electrodes on one or more substrates. In this work, we have utilized electro-actuation based DMF technology, integrated with suitably tailored resistive micro-heaters and temperature sensors, to achieve chip based real-time, quantitative PCR (qRT-PCR). This qRT-PCR micro-device was utilized to detect and quantify the presence of influenza A and C virus nucleic acids, using in-vitro synthesized viral RNA segments. The experimental analysis of the DMF micro-device confirms its capabilities in qRT-PCR based detection and quantification of pathogen samples, with accuracy levels comparable to established commercial bench-top equipment (PCR efficiency ∼95%). The limit of detection (LOD) of the chip based qRT-PCR technique was estimated to be ∼5 copies of template RNA per PCR reaction.
Collapse
Affiliation(s)
- R Prakash
- Biosystems Research and Applications Group, Schulich School of Engineering, University of Calgary, Calgary, Alberta AB T2N 1N4, Canada
| | - K Pabbaraju
- Provincial Laboratory for Public Health of Alberta, ProvLAB, Calgary AB T2N4W4, Canada
| | - S Wong
- Provincial Laboratory for Public Health of Alberta, ProvLAB, Calgary AB T2N4W4, Canada
| | - A Wong
- Provincial Laboratory for Public Health of Alberta, ProvLAB, Calgary AB T2N4W4, Canada
| | - R Tellier
- Provincial Laboratory for Public Health of Alberta, ProvLAB, Calgary AB T2N4W4, Canada
- Department of Microbiology, Immunology and Infectious Diseases, University of Calgary, Calgary, Alberta T2N 1N4, Canada
| | - K V I S Kaler
- Biosystems Research and Applications Group, Schulich School of Engineering, University of Calgary, Calgary, Alberta AB T2N 1N4, Canada
| |
Collapse
|
12
|
Tang JW, Loh TP, Tambyah PA, Koay ESC. Influenza outbreaks in Singapore: epidemiology, diagnosis, treatment and prevention. Expert Rev Anti Infect Ther 2012; 10:751-60. [PMID: 22943399 DOI: 10.1586/eri.12.63] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
With the recent influenza A/H1N1 2009 pandemic still spreading through global populations, there has been an increased focus on optimizing the prevention, diagnosis and treatment of influenza infections, as well as the epidemiology of the virus. Clinical and epidemiological data on influenza infections in tropical countries have been relatively sparse until fairly recently, and it is the aim of this review to close some of these gaps by examining the behavior of influenza viruses in the tropical Singaporean population.
Collapse
Affiliation(s)
- Julian W Tang
- Alberta Provincial Laboratory for Public Health, University of Alberta Hospital, Edmonton, 8440-112 Street, Edmonton, AB T6G 2J2, Canada.
| | | | | | | |
Collapse
|
13
|
|
14
|
Pabbaraju K, Wong S, Drews SJ. Rethinking approaches to improve the utilization of nucleic acid amplification tests for detection and characterization of influenza A in diagnostic and reference laboratories. Future Microbiol 2011; 6:1443-60. [PMID: 22122441 DOI: 10.2217/fmb.11.126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Influenza A virus (IFVA) is a significant cause of respiratory infections worldwide and was also responsible for a recent pandemic in 2009. Laboratory identification of IFVA can guide antiviral therapy, assist in cohorting of patients and prevent antibiotic use. Characterization of the virus can track the emergence of novel strains, identify resistance and determine how circulating strains match with vaccine components. The gold standard for detection and characterization of IFVA is nucleic acid amplification technology (e.g., reverse transcriptase PCR [RT-PCR]), which must contend with a constantly evolving viral genome. Although molecular technology has been available for over two decades, there is still an operational gap between assay design and utilization of these tests for the diagnosis and characterization of IFVA. This review will discuss issues surrounding the implementation and use of RT-PCR for the identification and characterization of IFVA, and speculate on why RT-PCR has not been used more widely in clinical laboratories or moved closer to the patient. Newer, less widely used technologies that may change our laboratory practices will be identified and the authors will close with an attempt to identify some future applications of RT-PCR-based technologies for the detection and characterization of IFVA.
Collapse
Affiliation(s)
- Kanti Pabbaraju
- Provincial Laboratory for Public Health, Microbiology, 3030 Hospital Drive NW, Calgary, Alberta T2N 4W4, Canada
| | | | | |
Collapse
|
15
|
Fathima S, Drews SJ. Multi-analyte suspension arrays for the detection of common viruses: how viable are these assays in clinical laboratories? Expert Rev Anti Infect Ther 2011; 9:979-82. [PMID: 22029516 DOI: 10.1586/eri.11.111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
This article assesses the viability of a recently described multi-analyte suspension array for the detection of herpes simplex viruses-1 and -2, cytomegalovirus, Epstein-Barr virus, human papillomavirus and hepatitis B virus. This methodology was identified by the authors as a means of providing rapid, high-throughput multiplex assays that were easy to use. When paired with PCR assays, multi-analyte suspension arrays have the ability to overcome drawbacks associated with conventional detection methods such as long turnaround time, detection sensitivity and the ability to detect only one pathogen in each round of testing. However, the assays described in this article are still hampered by some key issues including limit of detection, the fact that median fluorescence intensity is not truly a quantitative diagnostic method, and that open molecular diagnostic systems can lead to contamination and/or increased operator-based errors. Although modern pressures on clinical virology laboratories have increased the need to develop a system that can detect pathogens in multiplexed assays, in the future these assays will only become more clinically relevant if they are designed with greater stakeholder input.
Collapse
Affiliation(s)
- Sumana Fathima
- Department of Microbiology, Immunology and Infectious Diseases, University of Calgary, Calgary, Alberta, Canada
| | | |
Collapse
|
16
|
Abstract
ABSTRACT
Diagnostic testing for respiratory viruses has been revolutionized by recent advances that have made rapid and highly accurate tests accessible to clinical laboratories, and it is important that these improved methods be utilized. Accurate detection of respiratory viruses is important in patient care, as it guides both therapy and infection control measures. On a larger scale, the CDC and its collaborating laboratories collect both data and isolates from clinical laboratories for national surveillance, and the use of high-quality tests in clinical laboratories can improve the quality of these data.
Collapse
|
17
|
Lee BE, Mukhi SN, May-Hadford J, Plitt S, Louie M, Drews SJ. Determination of the relative economic impact of different molecular-based laboratory algorithms for respiratory viral pathogen detection, including Pandemic (H1N1), using a secure web based platform. Virol J 2011; 8:277. [PMID: 21645365 PMCID: PMC3123288 DOI: 10.1186/1743-422x-8-277] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2011] [Accepted: 06/06/2011] [Indexed: 11/10/2022] Open
Abstract
Background During period of crisis, laboratory planners may be faced with a need to make operational and clinical decisions in the face of limited information. To avoid this dilemma, our laboratory utilizes a secure web based platform, Data Integration for Alberta Laboratories (DIAL) to make near real-time decisions. This manuscript utilizes the data collected by DIAL as well as laboratory test cost modeling to identify the relative economic impact of four proposed scenarios of testing for Pandemic H1N1 (2009) and other respiratory viral pathogens. Methods Historical data was collected from the two waves of the pandemic using DIAL. Four proposed molecular testing scenarios were generated: A) Luminex respiratory virus panel (RVP) first with/without US centers for Disease Control Influenza A Matrix gene assay (CDC-M), B) CDC-M first with/without RVP, C) RVP only, and D) CDC-M only. Relative cost estimates of different testing algorithm were generated from a review of historical costs in the lab and were based on 2009 Canadian dollars. Results Scenarios A and B had similar costs when the rate of influenza A was low (< 10%) with higher relative cost in Scenario A with increasing incidence. Scenario A provided more information about mixed respiratory virus infection as compared with Scenario B. Conclusions No one approach is applicable to all conditions. Testing costs will vary depending on the test volume, prevalence of influenza A strains, as well as other circulating viruses and a more costly algorithm involving a combination of different tests may be chosen to ensure that tests results are returned to the clinician in a quicker manner. Costing should not be the only consideration for determination of laboratory algorithms.
Collapse
|