1
|
Devriendt N, Paepe D, Serrano G, de Rooster H. Evaluation of different blood tests in dogs with extrahepatic portosystemic shunts to assess shunt closure after surgical treatment. Vet Surg 2022; 51:1142-1152. [PMID: 35729849 DOI: 10.1111/vsu.13840] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2021] [Revised: 02/13/2022] [Accepted: 05/21/2022] [Indexed: 12/01/2022]
Abstract
OBJECTIVE To determine the sensitivity and specificity of different individual and combined blood tests to assess extrahepatic portosystemic shunt (EHPSS) closure after gradual attenuation of EHPSS in dogs. STUDY DESIGN Clinical prospective study. ANIMALS Twenty client-owned dogs with EHPSS. METHODS Fasting ammonia (FA), preprandial, postprandial, and paired serum bile acids (SBA), the lidocaine/monoethylglycylxylidide (L/MEGX) test, and serum hyaluronic acid (SHA) were performed at diagnosis, and 1, 3, and 6 months postoperatively. Transsplenic portal scintigraphy was performed to determine EHPSS closure 3 months postoperatively. Their sensitivity and specificity in determining shunt closure postoperatively were calculated. RESULTS When assessing a single blood parameter, FA had the highest specificity (100%), whereas SHA and MEGX measured 15 min after lidocaine administration (T15) had the highest sensitivity (96.9% and 96.2%, respectively) for determining shunt closure postoperatively. The most promising blood test combinations were SHA (sensitivity 96.9%, specificity 81.8%), combined with the L/MEGX test (MEGX at T15: sensitivity 100%, specificity 72.4%) or the L/MEGX test (MEGX at T15) combined with either FA (sensitivity 100%, specificity 82.8%) or postprandial SBA (sensitivity 100%, specificity 81.5%). CONCLUSION Both SHA and the L/MEGX test were sensitive tests for determining shunt closure after gradual attenuation of EHPSS. Test performances could even be improved by combining these tests with each other or with traditional tests such as FA or postprandial SBA. CLINICAL SIGNIFICANCE Although SHA and the L/MEGX test are sensitive blood tests for determining EHPSS closure, especially when combined with traditional blood tests, imaging is still needed to confirm EHPSS closure.
Collapse
Affiliation(s)
- Nausikaa Devriendt
- Small Animal Department, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| | - Dominique Paepe
- Small Animal Department, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| | - Gonçalo Serrano
- Small Animal Department, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| | - Hilde de Rooster
- Small Animal Department, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| |
Collapse
|
2
|
Devriendt N, Serrano G, Stock E, Paepe D, de Rooster H. Diagnostic value of liver function tests and ultrasonography in dogs with suspected congenital portosystemic shunts. Vet Rec 2022; 190:e1381. [PMID: 35102558 DOI: 10.1002/vetr.1381] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Revised: 12/07/2021] [Accepted: 12/24/2021] [Indexed: 11/07/2022]
Abstract
BACKGROUND Diagnosing a congenital portosystemic shunt (cPSS) in dogs can be challenging. The current study aims to report diagnostic performance of fasting ammonia (FA), preprandial, postprandial and paired serum bile acids (SBA) and abdominal ultrasound (aUS) in dogs suspected of having a cPSS. METHODS Medical records of dogs suspected of having a cPSS at initial presentation were retrospectively reviewed. RESULTS In total, 192 dogs suspected of cPSS were included: a cPSS was confirmed in 147 dogs and excluded in 45 dogs. FA had the best combined sensitivity and specificity (77.4 and 93.3%, respectively) to diagnose cPSS. The sensitivity and negative predictive value were 100.0% for paired SBA, making paired SBA the best test to exclude cPSS in this population. Sensitivity and specificity of aUS were 80.8 and 90.0%, respectively. CONCLUSIONS In dogs with clinical signs compatible with cPSS, elevated FA is suggestive of cPSS, whereas normal paired SBA makes the presence of a cPSS unlikely. Although aUS is a useful tool to diagnose cPSS, additional imaging is required to visualize cPSS in almost 20% of cases. Furthermore, the localisation of cPSS can be misdiagnosed, especially in case of extrahepatic cPSS that do not insert into the prehepatic vena cava.
Collapse
Affiliation(s)
- Nausikaa Devriendt
- Small Animal Department, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| | - Gonçalo Serrano
- Small Animal Department, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
- Small Animal Clinic Hofheim, Hofheim, Germany
| | - Emmelie Stock
- Department of Medical Imaging of Domestic Animals and Small Animal Orthopaedics, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| | - Dominique Paepe
- Small Animal Department, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| | - Hilde de Rooster
- Small Animal Department, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| |
Collapse
|
3
|
Serrano G, Devriendt N, Paepe D, de Rooster H. Serum insulin-like growth factor-1 as a marker of improved liver function and surgical outcome in dogs with congenital extrahepatic portosystemic shunts. Vet J 2021; 274:105716. [PMID: 34252551 DOI: 10.1016/j.tvjl.2021.105716] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Revised: 06/19/2021] [Accepted: 07/06/2021] [Indexed: 11/29/2022]
Abstract
Serum insulin-like growth factor-1 concentration (sIGF-1c) is reduced in various hepatopathies in humans and dogs. This work aimed to evaluate sIGF-1c in dogs before and after congenital extrahepatic portosystemic shunt (cEHPSS) attenuation, in relation to surgical outcome (closed vs. persistent shunting). Secondarily, it aimed to assess if sIGF-1c can discriminate between cEHPSS and portal vein hypoplasia (PVH) and finally compare sIGF-1c ratio (postoperative/preoperative sIGF-1c) to pre-prandial serum bile acids (preBA), post-prandial bile acids (postBA), bile acid stimulation test (BAST) and fasting ammonia (FA), regarding surgical outcome. Thirty-nine dogs were included: 15 with closed cEHPSS, 15 with persistent shunting and nine with PVH. Transplenic portal scintigraphy was used to classifiy surgical outcome. There was no significant difference in sIGF-1c between dogs with cEHPSS and those with PVH (P > 0.05). Postoperative sIGF-1c increased in all dogs (P < 0.001 and P = 0.023 for closed and persistent shunting, respectively) and the increase was more pronounced in closed cEHPSS than in persistent shunting (P = 0.006). Using an optimal sIGF-1c ratio cut-off of 2.23, the sensitivity was 93.3% and the specificity was 66.7% for differentiation between surgical outcomes. Serum pre-prandial bile acids, postBA BAST and FA had sensitivities of 80%, 86.7%, 86.7%, 60%; and specificities of 100%, 93.3%, 93.3%, 100%, respectively. There was a greater increase in sIGF-1c after shunt closure than during persistent shunting; nevertheless sIGF-1c ratio was inferior to advanced imaging to assess surgical outcome.
Collapse
Affiliation(s)
- G Serrano
- Small Animal Department, Faculty of Veterinary Medicine, Ghent University, Campus Merelbeke, Salisburylaan 133, 9820 Merelbeke, Belgium.
| | - N Devriendt
- Small Animal Department, Faculty of Veterinary Medicine, Ghent University, Campus Merelbeke, Salisburylaan 133, 9820 Merelbeke, Belgium
| | - D Paepe
- Small Animal Department, Faculty of Veterinary Medicine, Ghent University, Campus Merelbeke, Salisburylaan 133, 9820 Merelbeke, Belgium
| | - H de Rooster
- Small Animal Department, Faculty of Veterinary Medicine, Ghent University, Campus Merelbeke, Salisburylaan 133, 9820 Merelbeke, Belgium
| |
Collapse
|
4
|
Weiler K, Kleber K, Zielinsky S, Moritz A, Bauer N. Analytical performance and method comparison of a quantitative point-of-care immunoassay for measurement of bile acids in cats and dogs. J Vet Diagn Invest 2021; 33:35-46. [PMID: 33112211 PMCID: PMC7756073 DOI: 10.1177/1040638720968784] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Point-of-care analyzers (POCAs) for quantitative assessment of bile acids (BAs) are scarce in veterinary medicine. We evaluated the Fuji Dri-Chem Immuno AU10V analyzer and v-BA test kit (Fujifilm) for detection of feline and canine total serum BA concentration. Results were compared with a 5th-generation assay as reference method and a 3rd-generation assay, both run on a bench-top analyzer. Analytical performance was assessed at 3 different concentration ranges, and with interferences. For method comparison, samples of 60 healthy and diseased cats and 64 dogs were included. Linearity was demonstrated for a BA concentration up to 130 µmol/L in cats (r = 0.99) and 110 µmol/L in dogs (r = 0.99). The analyzer showed high precision near the lower limit of quantification of 2 µmol/L reported by the manufacturer. Intra- and inter-assay coefficients of variation were < 5% for both species and all concentrations. Interferences were observed for bilirubin (800 mg/L) and lipid (4 g/L). There was excellent correlation with the reference method for feline (rs = 0.98) and canine samples (rs = 0.97), with proportional biases of 6.7% and -1.3%, respectively. However, a large bias (44.1%) was noted when the POCA was compared to the 3rd-generation assay. Total observed error was less than total allowable error at the 3 concentrations. The POCA reliably detected feline and canine BA in clinically relevant concentrations.
Collapse
Affiliation(s)
- Kristina Weiler
- Department of Veterinary Clinical Sciences, Clinical Pathology and Clinical Pathophysiology, Justus-Liebig-University, Giessen, Germany
| | - Katharina Kleber
- Department of Veterinary Clinical Sciences, Clinical Pathology and Clinical Pathophysiology, Justus-Liebig-University, Giessen, Germany
| | - Sabine Zielinsky
- Department of Veterinary Clinical Sciences, Clinical Pathology and Clinical Pathophysiology, Justus-Liebig-University, Giessen, Germany
| | - Andreas Moritz
- Department of Veterinary Clinical Sciences, Clinical Pathology and Clinical Pathophysiology, Justus-Liebig-University, Giessen, Germany
| | - Natali Bauer
- Department of Veterinary Clinical Sciences, Clinical Pathology and Clinical Pathophysiology, Justus-Liebig-University, Giessen, Germany
| |
Collapse
|
5
|
Nanfelt M, Macphail C, Kennedy KC, Eickhoff J. Interlaboratory agreement and handling variability for consistency of results in paired serum bile acid assays. J Am Anim Hosp Assoc 2011; 48:25-30. [PMID: 22186717 DOI: 10.5326/jaaha-ms-5684] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Paired serum bile acid (SBA) samples from 30 dogs with presumptive hepatobiliary disease and 30 apparently healthy dogs were submitted to three diagnostic laboratories to validate agreement between these facilities. Sensitivities and specificities ranged from 50% to 70% and from 74% to 85%, respectively, for all laboratories. The κ index confirmed almost perfect agreement between laboratories. Variation in sample handling and processing by different laboratories should not be considered a primary factor when aberrant SBA values are encountered. Documenting agreement between laboratories is essential as inconsistencies could direct unnecessary medical or surgical intervention when patients are evaluated at different hospitals during the course of their disease.
Collapse
Affiliation(s)
- Michelle Nanfelt
- Department of Clinical Sciences, James L. Voss Veterinary Medical Center, Colorado State University, Fort Collins, CO, USA
| | | | | | | |
Collapse
|
6
|
Solter PF, Hoffmann WE, Hoffman JW. Evaluation of an automated serum bile acids assay and the effect of bilirubin, hemoglobin, and lipid on the apparent bile acids yield. Vet Clin Pathol 2003; 21:114-118. [PMID: 12671791 DOI: 10.1111/j.1939-165x.1992.tb00596.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Philip F. Solter
- Department of Veterinary Pathology, College of Veterinary Medicine, University of Illinois at Urbana-Champaign, 2001 South Lincoln Avenue, Urbana, IL 61801
| | | | | |
Collapse
|
7
|
Cray C, Andreopoulos A. Comparison of Two Methods to Determine Plasma Bile Acid Concentrations in Healthy Birds. J Avian Med Surg 2003. [DOI: 10.1647/2002-022] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
8
|
Tisdall PL, Hunt GB, Tsoukalas G, Malik R. Post-prandial serum bile acid concentrations and ammonia tolerance in Maltese dogs with and without hepatic vascular anomalies. Aust Vet J 1995; 72:121-6. [PMID: 7646375 DOI: 10.1111/j.1751-0813.1995.tb15029.x] [Citation(s) in RCA: 24] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Post-prandial serum bile acid concentrations were measured in 200 Maltese dogs in an attempt to identify those with subclinical portosystemic shunts. Five of these were later shown to have hepatic pathology or abnormal liver function. In the other 195 Maltese, bile acid concentrations ranged from 1 to 362 mumol.L-1 (mean +/- SD, 70 +/- 50 mumol.L-1; median, 65.0 mumol.L-1). Of these, 79% were above the reference range (0 to 31 mumol.L-1) established from 23 mixed-breed control dogs. It was therefore not possible to determine the prevalence of subclinical portosystemic shunts on the basis of bile acid determinations. Further investigation of liver function was performed to investigate why bile acid concentrations were increased in these dogs. Rectal ammonia tolerance tests were normal in 102 of 106 Maltese tested and liver samples (11 dogs) and plasma biochemistry profiles (9 dogs) demonstrated no significant hepatic disease or dysfunction. Of 2 Maltese with hyperammonaemia after administration of ammonium chloride, one had a large congenital portosystemic shunt that was confirmed at surgery. In the other there were no macroscopic portosystemic communications, but a liver biopsy showed histological changes consistent with microscopic portovascular dysplasia. Total serum bile acid concentrations were consistently lower when assessed by high-performance liquid chromatography than by an enzymatic spectrophotometric method. This discrepancy was substantially larger in Maltese than in control dogs, suggesting the presence of an additional reacting substance in the serum of Maltese dogs.
Collapse
Affiliation(s)
- P L Tisdall
- Department of Veterinary Anatomy, University of Sydney, New South Wales
| | | | | | | |
Collapse
|
9
|
Anwer MS, Meyer DJ. Bile acids in the diagnosis, pathology, and therapy of hepatobiliary diseases. Vet Clin North Am Small Anim Pract 1995; 25:503-17. [PMID: 7785176 DOI: 10.1016/s0195-5616(95)50039-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Bile acids are normally confined in the enterohepatic circulation in which they play an important role in bile formation, biliary lipid excretion, and intestinal lipid absorption. In hepatobiliary diseases, bile acids escape the confinement of the enterohepatic circulation, allowing the measurement of the serum total bile acid concentration as a diagnostic indicator. Accumulation of certain bile acids within the hepatocyte, amplified as a consequence of cholestatic hepatobiliary disease, probably enhances cytotoxicity and leads to secondary pathology. Ursodeoxycholate, a bile acid with atypical physiological effects, may be useful in the treatment of various long-term cholestatic hepatobiliary diseases. Presently, most of the information on the toxicity and therapeutic usefulness of bile acids are based on studies in humans and experimental animals. Further studies, both basic and clinical, are needed to determine the pathologic as well as the therapeutic effects of bile acids in domestic animals.
Collapse
Affiliation(s)
- M S Anwer
- Department of Veterinary Medicine, Tufts University School of Veterinary Medicine, North Grafton, Massachusetts, USA
| | | |
Collapse
|
10
|
Abstract
Quantification of total serum bile acids is used as a method for appraising liver function and perfusion in contemporary small animal practice. This article provides a historical perspective and a comprehensive review of bile acid physiology, laboratory methodologies for bile acid quantification, and normal values published for total serum bile acids measured using the spectrophotometric enzymatic method and for serum bile acids measured using validated radioimmunoassay procedures. The variables influencing the enterohepatic circulation of bile acids and, consequently, the fasting and postprandial serum bile acid concentrations are discussed with the intent of clarifying the application of test results to clinical patients. A brief discussion of the therapeutic use of dehydrocholate and ursodeoxycholic acid in clinical patients is provided.
Collapse
Affiliation(s)
- S A Center
- Department of Clinical Sciences, Cornell University College of Veterinary Medicine, Ithaca, New York
| |
Collapse
|
11
|
Jensen AL. Variations in total bile acid concentration in serum of dogs after a test meal. ZENTRALBLATT FUR VETERINARMEDIZIN. REIHE A 1991; 38:241-6. [PMID: 1907781 DOI: 10.1111/j.1439-0442.1991.tb01008.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
The purpose of this study was to examine the variations in total serum bile acid (SBA) concentration following oral administration of corn oil (3.0 ml per kg body weight) to six fasted healthy dogs using a previously validated automated method (JENSEN, 1991) for the determination of SBA concentration. The preprandial SBA concentration was 2.22 mumol/l (0.64-6.41 mumol/l) (median, 0.025-0.975 fractiles). In the 2-6 hours postprandial period, all the SBA concentrations were significantly different from the preprandial value, but not significantly different from each other. For the total 2-6 hours postprandial period the SBA concentration was 7.89 mumol/l (1.39-22.24 mumol/l). From these results it may be suggested that the reference range for the preprandial SBA concentration in dogs is 0.64-6.41 mumol/l, and that the reference range for the postprandial SBA concentration in a blood sample obtained 2 hours after oral administration of corn oil is 1.39-22.24 mumol/l.
Collapse
Affiliation(s)
- A L Jensen
- Department of Clinical Studies, Royal Veterinary and Agricultural University, Frederiksberg, Denmark
| |
Collapse
|
12
|
Jensen AL. An automated method for determination of total bile acid concentration in canine serum. ZENTRALBLATT FUR VETERINARMEDIZIN. REIHE A 1991; 38:134-40. [PMID: 1906665 DOI: 10.1111/j.1439-0442.1991.tb00993.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
The purpose of the study was to evaluate an automated modification of the enzymatic method, Enzabile (Nycomed) for the determination of total bile acid concentration in canine serum. Evaluation of the automated method was accomplished by measuring the within-run and between-day variation, by assessment of accuracy, and by assessment of detectability of the method. The automated method was found to correlate well with the original Enzabile (Nycomed) method. The resulting regression equation was found to be: y = 5.81 + 1.09 x, r = 0.99. Also, the variations and the detection limit of the automated method were smaller, respectively lower, compared to the reference method.
Collapse
Affiliation(s)
- A L Jensen
- Department of Clinical Studies, Royal Veterinary and Agricultural University, Frederiksberg, Denmark
| |
Collapse
|