1
|
Sink J, Peigh G, Speakman B, Banno J, Sanders D, Nso N, Waits G, Lohrmann G, Elsayed M, Carneiro H, Baman J, Pfenniger A, Patil KD, Arora R, Kim SS, Chicos AB, Lin AC, Passman RS, Knight BP, Dandamudi S, Kaplan RM, Huang H, Wasserlauf J, Verma N. Correlation between high- and low-voltage impedance measurements following subcutaneous implantable cardioverter-defibrillator implantation. Heart Rhythm 2024; 21:492-494. [PMID: 38159788 DOI: 10.1016/j.hrthm.2023.12.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 12/19/2023] [Accepted: 12/23/2023] [Indexed: 01/03/2024]
Affiliation(s)
- Joshua Sink
- Department of Internal Medicine, Northwestern University, Chicago, Illinois
| | - Graham Peigh
- Division of Cardiology, Northwestern University, Chicago, Illinois
| | | | - Joseph Banno
- Division of Cardiology, Corewell Health, Grand Rapids, Michigan
| | - David Sanders
- Division of Cardiology, Rush University Medical Center, Chicago, Illinois
| | - Nso Nso
- Division of Cardiology, Northshore University Health System, Evanston, Illinois
| | - George Waits
- Division of Cardiology, Medical University of South Carolina, Charleston, South Carolina
| | - Graham Lohrmann
- Division of Cardiology, Northwestern University, Chicago, Illinois
| | - Mahmoud Elsayed
- Division of Cardiology, Northwestern University, Chicago, Illinois
| | - Herman Carneiro
- Division of Cardiology, Northwestern University, Chicago, Illinois
| | - Jayson Baman
- Division of Cardiology, Northwestern University, Chicago, Illinois
| | - Anna Pfenniger
- Division of Cardiology, Northwestern University, Chicago, Illinois
| | | | - Rishi Arora
- Division of Cardiology, Northwestern University, Chicago, Illinois
| | - Susan S Kim
- Division of Cardiology, Northwestern University, Chicago, Illinois
| | | | - Albert C Lin
- Division of Cardiology, Northwestern University, Chicago, Illinois
| | - Rod S Passman
- Division of Cardiology, Northwestern University, Chicago, Illinois
| | - Bradley P Knight
- Division of Cardiology, Northwestern University, Chicago, Illinois
| | | | - Rachel M Kaplan
- Division of Cardiology, Medical University of South Carolina, Charleston, South Carolina
| | - Henry Huang
- Division of Cardiology, Rush University Medical Center, Chicago, Illinois
| | - Jeremiah Wasserlauf
- Division of Cardiology, Northshore University Health System, Evanston, Illinois
| | - Nishant Verma
- Division of Cardiology, Northwestern University, Chicago, Illinois.
| |
Collapse
|
2
|
Doldi F, Frommeyer G, Löher A, Ellermann C, Wolfes J, Güner F, Zerbst M, Engelke H, Korthals D, Reinke F, Eckardt L, Willy K. Validation of the PRAETORIAN score in a large subcutaneous implantable cardioverter-defibrillator collective: Usefulness in clinical routine. Heart Rhythm 2024:S1547-5271(24)00204-2. [PMID: 38382685 DOI: 10.1016/j.hrthm.2024.02.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 01/20/2024] [Accepted: 02/12/2024] [Indexed: 02/23/2024]
Abstract
BACKGROUND To assess the risk of unsuccessful conversion of ventricular fibrillation during defibrillation testing (DFT) with the subcutaneous implantable cardioverter-defibrillator (S-ICD), the PRAETORIAN score has been proposed. OBJECTIVE The purpose of this study was to validate the PRAETORIAN score in a large S-ICD collective. METHODS A retrospective single-center analysis of S-ICD patients receiving intraoperative DFT was performed. DFT was performed using a stepwise protocol with 65-J standard polarity, change of polarity, increase to 80 J, and repositioning if necessary. If all DFTs failed, we switched to a transvenous ICD. RESULTS Overall, 398 patients were analyzed (268 male [67.3%]; mean age 42.4 ± 15.9 years; mean body mass index [BMI] 25.9 ± 4.8 kg/m2). Successful DFT with the first ICD shock was observed in 264 patients (66.3%). One hundred fourteen patients were defibrillated with the second (n = 104) or third (n = 10) DFT after changing shock polarity and/or shock energy. Overall, 20 patients needed at least 3 DFT (ie, 80 J and/or re-positioning). The majority (n = 88 [65.7%]) of DFT failures occurred before 2015 with the first-generation S-ICD. PRAETORIAN score was an independent predictor of DFT failure (odds ratio [OR] 1.007; 95% confidence interval [CI] 1.003-1.011 P ≤.001), while whereas BMI alone was not (P = .31). Presence of hypertrophic cardiomyopathy (HCM) (OR 2.6; 95% CI 1.3-4.4; P = .004) was predictive for at least 1 unsuccessful DFT in our multivariate regression analysis. CONCLUSION PRAETORIAN score proved to be a useful and valid predictive tool for successful DFT, whereas BMI only had a limited role. Patients with HCM were at increased risk for DFT failure or needed higher DFT energy.
Collapse
Affiliation(s)
- Florian Doldi
- Department for Cardiology II, Electrophysiology, University Hospital Münster, Münster, Germany.
| | - Gerrit Frommeyer
- Department for Cardiology II, Electrophysiology, University Hospital Münster, Münster, Germany
| | - Andreas Löher
- Department for Cardio-Thoracic Surgery, University Hospital Münster, Münster, Germany
| | - Christian Ellermann
- Department for Cardiology II, Electrophysiology, University Hospital Münster, Münster, Germany
| | - Julian Wolfes
- Department for Cardiology II, Electrophysiology, University Hospital Münster, Münster, Germany
| | - Fatih Güner
- Department for Cardiology II, Electrophysiology, University Hospital Münster, Münster, Germany
| | - Mathis Zerbst
- Department for Cardiology II, Electrophysiology, University Hospital Münster, Münster, Germany
| | - Hauke Engelke
- Department for Cardiology II, Electrophysiology, University Hospital Münster, Münster, Germany
| | - Dennis Korthals
- Department for Cardiology II, Electrophysiology, University Hospital Münster, Münster, Germany
| | - Florian Reinke
- Department for Cardiology II, Electrophysiology, University Hospital Münster, Münster, Germany
| | - Lars Eckardt
- Department for Cardiology II, Electrophysiology, University Hospital Münster, Münster, Germany
| | - Kevin Willy
- Department for Cardiology II, Electrophysiology, University Hospital Münster, Münster, Germany
| |
Collapse
|
3
|
Kasagawa A, Nakajima I, Nakayama Y, Togashi D, Sasaki K, Matsuda H, Harada T, Akashi YJ. Preoperative Prediction of Shock Impedance for Subcutaneous Implantable Cardioverter Defibrillator Using Chest Computed Tomography. Circ J 2024:CJ-23-0229. [PMID: 38311419 DOI: 10.1253/circj.cj-23-0229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/10/2024]
Abstract
BACKGROUND High shock impedance is associated with conversion failure among patients with subcutaneous implantable cardioverter defibrillators (S-ICD). Currently, there is no preoperative assessment method for predicting high shock impedance. This study examined the efficacy of chest computed tomography (CT) as a preoperative evaluation tool to assess the shock impedance of S-ICDs.Methods and Results: The amount of adipose tissue adjacent to the device and anteroposterior diameter at the basal heart region were measured preoperatively using chest CT. We examined the correlation between these measurements and shock impedance at the conversion test. We enrolled 43 patients with S-ICDs (mean [±SD] age 54±15 years; body mass index 23±4 kg/m2; PRAETORIAN score 30-270 points; amount of adipose tissue 1,250±716 cm3), who underwent intraoperative conversion tests by inducing ventricular fibrillation, which was terminated with a 65-J shock. A sufficient concordance correlation coefficient was observed between the shock impedance and the amount of adipose tissue (r=0.616, P<0.01) and anteroposterior diameter (r=0.645, P<0.01). In multiple regression analysis, the amount of adipose tissue (β=0.439, P=0.009) and anteroposterior diameter (β=0.344, P=0.038) were identified as independent predictive factors of shock impedance. CONCLUSIONS The preoperative CT-measured amount of adipose tissue and basal heart anteroposterior diameter are independent predictors of shock impedance. These parameters may be more accurate in identifying higher shock impedance in patients with S-ICDs.
Collapse
Affiliation(s)
- Akira Kasagawa
- Division of Cardiology, St. Marianna University School of Medicine
| | - Ikutaro Nakajima
- Division of Cardiology, St. Marianna University School of Medicine
| | - Yui Nakayama
- Division of Cardiology, St. Marianna University School of Medicine
| | - Daisuke Togashi
- Division of Cardiology, St. Marianna University School of Medicine
| | - Kenichi Sasaki
- Division of Cardiology, St. Marianna University School of Medicine
| | - Hisao Matsuda
- Division of Cardiology, St. Marianna University School of Medicine, Yokohama City Seibu Hospital
| | - Tomoo Harada
- Division of Cardiology, St. Marianna University School of Medicine
| | | |
Collapse
|
4
|
Francia P, Ziacchi M, Adduci C, Ammendola E, Pieragnoli P, De Filippo P, Rapacciuolo A, Rella V, Migliore F, Viani S, Musumeci MB, Biagini E, Lovecchio M, Baldini R, Falasconi G, Autore C, Biffi M, Cecchi F. Clinical course of hypertrophic cardiomyopathy patients implanted with a transvenous or subcutaneous defibrillator. Europace 2023; 25:euad270. [PMID: 37724686 PMCID: PMC10507661 DOI: 10.1093/europace/euad270] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Accepted: 08/09/2023] [Indexed: 09/21/2023] Open
Abstract
AIMS The implantable cardioverter-defibrillator (ICD) is a life-saving therapy in patients with hypertrophic cardiomyopathy (HCM) at risk of sudden cardiac death. Implantable cardioverter-defibrillator complications are of concern. The subcutaneous ICD (S-ICD) does not use transvenous leads and is expected to reduce complications. However, it does not provide bradycardia and anti-tachycardia pacing (ATP). The aim of this study was to compare appropriate and inappropriate ICD interventions, complications, disease-related adverse events and mortality between HCM patients implanted with a S- or transvenous (TV)-ICD. METHODS AND RESULTS Consecutive HCM patients implanted with a S- (n = 216) or TV-ICD (n = 211) were enrolled. Propensity-adjusted cumulative Kaplan-Meier curves and multivariate Cox proportional hazard ratios were used to compare 5-year event-free survival and the risk of events. The S-ICD patients had lower 5-year risk of appropriate (HR: 0.32; 95%CI: 0.15-0.65; P = 0.002) and inappropriate (HR: 0.44; 95%CI: 0.20-0.95; P = 0.038) ICD interventions, driven by a high incidence of ATP therapy in the TV-ICD group. The S- and TV-ICD patients experienced similar 5-year rate of device-related complications, albeit the risk of major lead-related complications was lower in S-ICD patients (HR: 0.17; 95%CI: 0.038-0.79; P = 0.023). The TV- and S-ICD patients displayed similar risk of disease-related complications (HR: 0.64; 95%CI: 0.27-1.52; P = 0.309) and mortality (HR: 0.74; 95%CI: 0.29-1.87; P = 0.521). CONCLUSION Hypertrophic cardiomyopathy patients implanted with a S-ICD had lower 5-year risk of appropriate and inappropriate ICD therapies as well as of major lead-related complications as compared to those implanted with a TV-ICD. Long-term comparative follow-up studies will clarify whether the lower incidence of major lead-related complications will translate into a morbidity or survival benefit.
Collapse
Affiliation(s)
- Pietro Francia
- Cardiology, Department of Clinical and Molecular Medicine, Sant’Andrea Hospital, University Sapienza, Rome, Italy
| | - Matteo Ziacchi
- Institute of Cardiology, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico S.Orsola-Malpighi, Bologna, Italy
| | - Carmen Adduci
- Cardiology, Department of Clinical and Molecular Medicine, Sant’Andrea Hospital, University Sapienza, Rome, Italy
| | - Ernesto Ammendola
- Department of Translational Medical Sciences, University of Campania ‘Luigi Vanvitelli’, Monaldi Hospital, Naples, Italy
| | - Paolo Pieragnoli
- Careggi University Hospital, University of Florence, Florence, Italy
| | | | - Antonio Rapacciuolo
- Department of Advanced Biomedical Sciences, Federico II University, Naples, Italy
| | - Valeria Rella
- Department of Cardiovascular, Neural and Metabolic Sciences, IRCCS, Istituto Auxologico Italiano, San Luca Hospital, Milan, Italy
| | - Federico Migliore
- Department of Cardiac, Thoracic Vascular Sciences and Public Health University of Padova, Padova, Italy
| | - Stefano Viani
- Second Cardiology Division, Cardio-Thoracic and Vascular Department, University Hospital of Pisa, Pisa, Italy
| | - Maria Beatrice Musumeci
- Cardiology, Department of Clinical and Molecular Medicine, Sant’Andrea Hospital, University Sapienza, Rome, Italy
| | - Elena Biagini
- Institute of Cardiology, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico S.Orsola-Malpighi, Bologna, Italy
| | | | - Rossella Baldini
- Cardiology, Department of Clinical and Molecular Medicine, Sant’Andrea Hospital, University Sapienza, Rome, Italy
| | - Giulio Falasconi
- Campus Clínic, University of Barcelona, Barcelona, Spain
- IRCCS Humanitas Research Hospital, Milan, Italy
| | - Camillo Autore
- Cardiology, Department of Clinical and Molecular Medicine, Sant’Andrea Hospital, University Sapienza, Rome, Italy
| | - Mauro Biffi
- Institute of Cardiology, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico S.Orsola-Malpighi, Bologna, Italy
| | - Franco Cecchi
- Careggi University Hospital, University of Florence, Florence, Italy
- Department of Cardiovascular, Neural and Metabolic Sciences, IRCCS, Istituto Auxologico Italiano, San Luca Hospital, Milan, Italy
| |
Collapse
|
5
|
Budrejko S, Kempa M, Krupa W, Królak T, Fabiszak T, Raczak G. Real-Life Inter-Rater Variability of the PRAETORIAN Score Values. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:9700. [PMID: 35955057 PMCID: PMC9368382 DOI: 10.3390/ijerph19159700] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Revised: 08/01/2022] [Accepted: 08/05/2022] [Indexed: 06/15/2023]
Abstract
(1) Background: The PRAETORIAN score is a tool developed for postoperative evaluation of the position of subcutaneous implantable cardioverter-defibrillator systems. The aim of our study was to evaluate the real-life inter-rater variability of the PRAETORIAN score, based on chest radiographs of S-ICD patients reviewed by independent clinical raters. (2) Methods: Postoperative chest X-rays of patients that underwent S-ICD implantation were evaluated by five clinical raters who gave values of the PRAETORIAN score. Ratings were then compared in a fully crossed manner to determine the inter-rater variability of the attributed scores. (3) Results: In total, 87 patients were included in the study. In the case of the most important final risk category of the PRAETORIAN score, the mean Light's kappa was 0.804, the Fleiss' kappa was 0.249, and the intraclass correlation was 0.38. The final risk category was identically determined by all five raters in 75.86% of patients, by four raters in 14.94%, and by three raters in 9.20% of patients. (4) Conclusions: The overall inter-rater variability of the PRAETORIAN score in a group of electrophysiologists experienced in S-ICD implantation, yet previously naive to the PRAETORIAN score, and self-trained in its utilization, was only modest in our study. Appropriate use of the score might require training of clinical raters.
Collapse
Affiliation(s)
- Szymon Budrejko
- Department of Cardiology and Electrotherapy, Medical University of Gdansk, 80-214 Gdansk, Poland
| | - Maciej Kempa
- Department of Cardiology and Electrotherapy, Medical University of Gdansk, 80-214 Gdansk, Poland
| | - Wojciech Krupa
- Department of Cardiology and Internal Diseases, Collegium Medicum, Nicolaus Copernicus University, 87-100 Bydgoszcz, Poland
| | - Tomasz Królak
- Department of Cardiology and Electrotherapy, Medical University of Gdansk, 80-214 Gdansk, Poland
| | - Tomasz Fabiszak
- Department of Cardiology and Internal Diseases, Collegium Medicum, Nicolaus Copernicus University, 87-100 Bydgoszcz, Poland
| | - Grzegorz Raczak
- Department of Cardiology and Electrotherapy, Medical University of Gdansk, 80-214 Gdansk, Poland
| |
Collapse
|
6
|
Droghetti A, Pecora D, Maffè S, Badolati S, Pepi P, Nicolis D, Lupo P, Lovecchio M, Valsecchi S, Ottaviano L. "Shift and cover technique": conservative management of complications for the rescue of S-ICD subcutaneous implantable defibrillator systems. J Interv Card Electrophysiol 2022:10.1007/s10840-022-01312-y. [PMID: 35927601 DOI: 10.1007/s10840-022-01312-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Accepted: 07/18/2022] [Indexed: 11/25/2022]
Abstract
BACKGROUND The risk of complications has been shown to be lower with subcutaneous implantable defibrillator (S-ICD) than with conventional ICDs. Given the low frequency of complications, experience of how to manage them is limited. In this paper, we describe generator- and lead-related complications recorded in a series of S-ICD patients, and we propose our conservative approach to managing them. METHODS The study cohort consisted of S-ICD patients who were referred to our institution owing to generator- or lead-related complications requiring surgical intervention. With our "shift and cover" approach, the system component involved is moved from its original position to an alternative, more protected location. In the case of the generator, this involves moving it to an intermuscular pocket. In the case of infections at the parasternal scar, the electrode sleeve is moved away from its original location, stitched, and then covered with the muscular fascia. RESULTS Fourteen S-ICD patients were referred to our institution owing to system-related complications. Complications involved the generator in 7 cases (deep pocket infections with erosion, extrusion, or pain), the lead in 5 cases (parasternal infections at the xyphoid incision site), and both the generator and the lead in 2 cases. Complications were managed without completely removing the device and resolved in a single surgical session with no intraoperative complications. During defibrillation testing, the first shock at 65 J was effective in all patients. The shock impedance after revision was significantly lower than that measured during first implantation (59 ± 10 Ohm versus 86 ± 24 Ohm, P = 0.013). In all cases, the cosmetic result was satisfactory. No complications or recurrent infections were reported at the 12-month follow-up visit. CONCLUSIONS The proposed conservative approach was successful in managing S-ICD complications. The revision procedure allowed to optimize the system configuration in terms of the defibrillation vector, resulting in lower shock impedance values and better device positioning.
Collapse
Affiliation(s)
- Andrea Droghetti
- Thoracic Surgery Division, ASST Mantova, Viale Lago Paiolo 10, 46100, Mantua, Italy.
| | - Domenico Pecora
- Electrophysiology Unit, Cardiovascular Department, Poliambulanza Institute Hospital Foundation, Brescia, Italy
| | - Stefano Maffè
- Division of Cardiology, Ospedale SS, Trinità, Borgomanero Hospital, Novara, Italy
| | - Sandra Badolati
- Department of Cardiology, S. Andrea Hospital, La Spezia, Italy
| | | | | | - Pierpaolo Lupo
- Arrhythmia and Electrophysiology Center,I.R.C.C.S. MultiMedica, Sesto San Giovanni (MI), Italy
| | | | | | - Luca Ottaviano
- Arrhythmia and Electrophysiology unit, Cardiothoracic Department Clinical Institute S. Ambrogio, Milan, Italy
| |
Collapse
|
7
|
Bisignani A, De Bonis S, Cavaliere AL, Lovecchio M, Valsecchi S, Bisignani G. Stability of the subcutaneous defibrillator implanted with the intermuscular two-incision technique: 1-year follow-up. J Cardiovasc Med (Hagerstown) 2022; 23:484-486. [PMID: 35763773 DOI: 10.2459/jcm.0000000000001311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Antonio Bisignani
- Institute of Cardiology, Catholic University of the Sacred Heart, Rome
| | - Silvana De Bonis
- Department of Cardiology, Ospedale 'Ferrari', Castrovillari, Cosenza
| | | | | | | | | |
Collapse
|
8
|
Francia P, Olivotto I, Lambiase PD, Autore C. Implantable cardioverter-defibrillators for hypertrophic cardiomyopathy: The Times They Are a-Changin'. Europace 2021; 24:1384-1394. [PMID: 34966939 DOI: 10.1093/europace/euab309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2021] [Accepted: 12/01/2021] [Indexed: 11/14/2022] Open
Abstract
The implantable cardioverter-defibrillator (ICD) is a life-saving therapy in patients with hypertrophic cardiomyopathy (HCM) at high risk of sudden cardiac death. The heterogeneity of clinical scenarios in HCM and the availability of ICDs with distinct characteristics emphasizes the need for selecting the right device for the right patient. There is growing awareness that unnecessarily complex devices can lead to short- and long-term complications without adding significant clinical benefits. Young patients have the greatest potential years of life gained from the ICD but are also most exposed to device-related complications. This increases the complexity of decision-making of ICD prescription in these often otherwise well patients in whom device selection should be tailored to preserve survival benefit without introducing morbidity. In the light of the multiple clinical phenotypes characterizing HCM, the present article offers evidence-based perspectives helpful in predicting the individual impact of the ICD and choosing the most appropriate device.
Collapse
Affiliation(s)
- Pietro Francia
- Division of Cardiology, Department of Clinical and Molecular Medicine, St. Andrea Hospital, Sapienza University, Rome, Italy
| | - Iacopo Olivotto
- Cardiomyopathy Unit, Careggi University Hospital. Dept of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Pier D Lambiase
- Institute of Cardiovascular Science, UCL Department of Cardiology, Barts Heart Centre, London, UK
| | - Camillo Autore
- Division of Cardiology, Department of Clinical and Molecular Medicine, St. Andrea Hospital, Sapienza University, Rome, Italy
| |
Collapse
|