1
|
Cantelli V, Meirelles MT, Della Bona A. Fatigue methods for evaluating translucent dental zirconia. J Dent 2024; 148:105242. [PMID: 39009334 DOI: 10.1016/j.jdent.2024.105242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2024] [Revised: 07/11/2024] [Accepted: 07/12/2024] [Indexed: 07/17/2024] Open
Abstract
OBJECTIVE To investigate fatigue methods for the evaluation of translucent zirconia and to associate in vitro failures with clinically reported ones. DATA Studies published in English that used fatigue tests on dental translucent zirconia. SOURCES Two databases (MEDLINE/PubMed and Scopus) were electronically searched without any restriction on year of publication. STUDY SELECTION A total of 4555 studies were identified. After removal of duplicates (78) and irrelevant articles (4316) that did not meet the inclusion criteria, 161 articles were considered eligible based on their titles and abstracts. These articles were fully read, leading to the inclusion of 41 studies in the review. RESULTS The most widely used fatigue method for evaluation of translucent zirconia was step-stress (18 articles), followed by staircase (seven articles), and step-wise (two articles). Most studies had been conducted in a wet environment with the use of a stainless steel piston to apply load to cemented structures on a dentin-like substrate. Most fracture analyses indicated the fracture originated on the cementation or contact surface where the load was applied. Moreover, studies that utilized anatomical structures (dental crowns) reported fractures starting at the cervical margin of the crowns. CONCLUSION Most studies used the step-stress method. Only three studies reported failures similar to those found in clinical trials that used translucent zirconia restorations. CLINICAL SIGNIFICANCE The study findings can assist on correlating clinical failures to the ones observed in vitro.
Collapse
Affiliation(s)
- Viviane Cantelli
- Post-graduate Program in Dentistry, School of Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil
| | - Marcelo Tapparo Meirelles
- Graduate Program in Dentistry, School of Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil
| | - Alvaro Della Bona
- Post-graduate Program in Dentistry, School of Dentistry, University of Passo Fundo, Passo Fundo, RS, Brazil.
| |
Collapse
|
2
|
Çakmak G, Donmez MB, Molinero-Mourelle P, Kahveci Ç, Abou-Ayash S, Peutzfeldt A, Yilmaz B. Fracture resistance of additively or subtractively manufactured resin-based definitive crowns: Effect of restorative material, resin cement, and cyclic loading. Dent Mater 2024; 40:1072-1077. [PMID: 38777731 DOI: 10.1016/j.dental.2024.05.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Accepted: 05/15/2024] [Indexed: 05/25/2024]
Abstract
OBJECTIVE To evaluate how restorative material, resin cement, and cyclic loading affect the fracture resistance of resin-based crowns fabricated by using additive or subtractive manufacturing. METHODS A right first molar crown standard tessellation language (STL) file was used to fabricate 120 crowns from one subtractively manufactured polymer-infiltrated ceramic network (SM) and two additively manufactured resin composites (AM-B and AM-S) (N = 40). These crowns were randomly divided into 4 groups within each material according to the dual-polymerizing resin cement to be used (RX and PN) and the aging condition (n = 10). After cementation, the crowns without cyclic loading were subjected to fracture testing, while the others were first cyclically loaded (1.7 Hz, 1.2 million cycles, and 49-N load) and then subjected to fracture testing. Data were analyzed with generalized linear model analysis (α = .05). RESULTS Fracture resistance of the crowns was affected by material, resin cement, and cyclic loading (P ≤ .030). However, none of the interactions significantly affected fracture resistance of tested crowns (P ≥ .140). Among tested materials, SM had the highest fracture resistance, whereas AM-B had the lowest (P ≤ .025). RX led to higher fracture resistance, and cyclic loading decreased the fracture resistance (P ≤ .026). SIGNIFICANCE Tested materials can be considered reliable in terms of fracture resistance in short- or mid-term (5 years of intraoral simulation) when used for single molar crowns with 2 mm occlusal thickness. In the long term, polymer-infiltrated ceramic network crowns cemented with RelyX Universal may provide promising results and be less prone to complications considering higher fracture resistance values obtained.
Collapse
Affiliation(s)
- Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Mustafa Borga Donmez
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey.
| | - Pedro Molinero-Mourelle
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Conservative Dentistry and Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, Madrid, Spain
| | | | - Samir Abou-Ayash
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Anne Peutzfeldt
- Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Odontology, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, OH, USA
| |
Collapse
|
3
|
Shely A, Lugassy D, Anufriev M, Nissan J, Rauchwerger O, Ben-Izhack G. SEM Evaluation of the Marginal Gap of Zirconia-Reinforced Lithium Silicate Full Crowns and the Effect of Post Crystallization: An In Vitro Study. Dent J (Basel) 2024; 12:61. [PMID: 38534285 DOI: 10.3390/dj12030061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 02/21/2024] [Accepted: 02/29/2024] [Indexed: 03/28/2024] Open
Abstract
BACKGROUND This study compared the influence of crystallization on marginal gap adaptation by using computer-aided design and manufacturing (CAD-CAM) for producing monolithic zirconia-reinforced lithium silicate (ZLS) ceramic crowns. METHODS A total of 25 plastic teeth were scanned using a Primescan intra-oral scanner (IOS), and ZLS crowns were ground. For each unit (abutment and crown), the marginal gap was evaluated pre crystallization and post crystallization at four regions of interest through the use of a scanning electron microscope (SEM). To compare the marginal gap between the two groups, a Kolmogorov-Smirnov test performed on the study variables indicated a normal distribution (p > 0.05) followed by paired samples T-tests (α = 0.0005). RESULTS After crystallization, there were significantly higher circumferential marginal gaps (CMGs) for all four surfaces (distal (p = 0.0005), mesial (p = 0.0005), palatal (p = 0.0005), and buccal (p = 0.0005)). The total mean marginal gap (MMG) revealed a significantly higher result for the post-crystallization group (79.82 ± 7.86 μm) compared to the pre-crystallization group (24.25 ± 5.49 μm). CONCLUSIONS The post-crystallization group showed a significantly higher marginal gap compared to the pre-crystallization group in all parameters, but both groups were in the clinically accepted threshold (<120 microns). In terms of the marginal gap, it is arguable whether to carry out post-crystallization for CELTRA® DUO crowns and achieve better mechanical properties but significantly increase the marginal gap.
Collapse
Affiliation(s)
- Asaf Shely
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Diva Lugassy
- Department of Orthodontics, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Maxim Anufriev
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Joseph Nissan
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Olisya Rauchwerger
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Gil Ben-Izhack
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| |
Collapse
|
4
|
Salem BO, Elshehawi DM, Elnaggar GA. Fracture resistance of pressed ZLS crowns versus pressed LD crowns under thermo-mechanical cycling. Braz Dent J 2022; 33:103-109. [PMID: 36477957 PMCID: PMC9733374 DOI: 10.1590/0103-6440202204993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Accepted: 10/13/2022] [Indexed: 12/12/2022] Open
Abstract
The aim of this study was conducted to assess the fracture resistance of zirconia reinforced lithium silicate all ceramic material "Celtra Press" compared to lithium disilicate one "IPS e-max Press" under simulated oral conditions. Fourteen ceramic crowns were fabricated on epoxy dies which were duplicated from stainless steel master die and divided into two equal groups (n=7) according to the material of construction; Group A: Crowns fabricated with IPS e-max Press material and Group B: Crowns fabricated with Celtra Press material. The crowns were then cemented onto their corresponding dies with a self-adhesive resin cement and subjected to thermocycling and cyclic loading. Then they were loaded to fractur in a universal testing machine. The results were tabulated and statistically analyzed using Kolmogorov-Smirnov and Shapiro-Wilk tests. Student t-test used to compare mean values. The significance level was set at P ≤ 0.05 and 95% Confidence interval. Statistical analysis was performed using Graph Pad Instat (Graph Pad, Inc.) software for windows. The mean ± SD values of fracture resistance were recorded for lithium Disilicate group (1706.01 ±154.32 N) meanwhile the mean ± SD value recorded with celtra group were (1550.67±196.71 N). Zirconia reinforced lithium silicate ceramic crowns produced comparable fracture resistance values to lithium disilicate ceramic crowns and both tested materials are within the clinically acceptable values in the posterior area.
Collapse
Affiliation(s)
- Basma Osama Salem
- Faculty of dentistry, Cairo university, department of fixed prosthodontics, Giza, Egypt
| | - Dina Magdy Elshehawi
- Faculty of dentistry, Cairo university, department of fixed prosthodontics, Giza, Egypt
| | | |
Collapse
|
5
|
Abualsaud R, Abussaud M, Assudmi Y, Aljoaib G, Khaled A, Alalawi H, Akhtar S, Matin A, Gad MM. Physiomechanical and Surface Characteristics of 3D-Printed Zirconia: An In Vitro Study. MATERIALS (BASEL, SWITZERLAND) 2022; 15:6988. [PMID: 36234329 PMCID: PMC9572578 DOI: 10.3390/ma15196988] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/17/2022] [Revised: 10/01/2022] [Accepted: 10/04/2022] [Indexed: 06/16/2023]
Abstract
The objective of this study is to examine the physiomechanical and surface properties of 3D-printed zirconia in comparison to milled zirconia. A total of 80 disc-shaped (14 × 1.5 ± 0.2 mm) specimens (20 milled and 60 3D-printed (at three different orientations; horizontal, vertical, and tilted)) were manufactured from 3-mol% yttria-stabilized tetragonal zirconia. Five specimens per group were evaluated for crystalline phase, grain size, density, porosity, surface roughness, wettability, microhardness, and SEM analysis of the surface. Biaxial flexural strength (BFS) was measured (n = 15) followed by Weibull analysis and SEM of fractured surfaces. Statistical analysis was performed using one-way ANOVA and Tukey’s post hoc test at α = 0.05. All groups showed a predominant tetragonal phase, with a 450 nm average grain size. There was no significant difference between groups with regards to density, porosity, and microhardness (p > 0.05). The tilted group had the highest surface roughness (0.688 ± 0.080 µm), significantly different from the milled (p = 0.012). The horizontal group presented the highest contact angle (89.11 ± 5.22°), significantly different from the milled and tilted (p > 0.05). The BFS of the milled group (1507.27 ± 340.10 MPa) was significantly higher than all other groups (p < 0.01), while vertical and tilted had a similar BFS that was significantly lower than horizontal (p < 0.005). The highest and lowest Weibull modulus were seen with tilted and milled, respectively. Physical properties of all groups were comparable. The surface roughness of the tilted group was higher than milled. The horizontal group had the highest hydrophobicity. Printing orientations influenced the flexural strength of 3D-printed zirconia. Clinical implications: This study demonstrates how the printing orientation affects the physiomechanical characteristics of printed zirconia.
Collapse
Affiliation(s)
- Reem Abualsaud
- Substitutive Dental Sciences Department, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia
| | - Maissan Abussaud
- Intern, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia
| | - Yara Assudmi
- Intern, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia
| | - Ghadah Aljoaib
- Intern, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia
| | - Abrar Khaled
- Intern, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia
| | - Haidar Alalawi
- Substitutive Dental Sciences Department, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia
| | - Asif Matin
- IRC Membranes & Water Security, King Fahd University of Petroleum & Minerals, Dhahran 31261, Saudi Arabia
| | - Mohammed M. Gad
- Substitutive Dental Sciences Department, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia
| |
Collapse
|
6
|
Load-to-Failure Resistance and Optical Characteristics of Nano-Lithium Disilicate Ceramic after Different Aging Processes. MATERIALS 2022; 15:ma15114011. [PMID: 35683309 PMCID: PMC9182075 DOI: 10.3390/ma15114011] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Revised: 06/02/2022] [Accepted: 06/02/2022] [Indexed: 01/27/2023]
Abstract
The aim of this study was to compare the load-to-failure resistance and optical properties of nano-lithium disilicate (NLD) with lithium disilicate (LDS) and zirconia-reinforced lithium silicate (ZLS) in different aging processes. Thirty crowns were milled from NLD, LDS, and ZLS (n = 10). All crowns were subjected to thermomechanical aging and loaded until catastrophic failure. Ten specimens from each material were prepared in two different thicknesses (0.7 mm and 1.5 mm, n = 5), and color coordinates were measured before and after coffee thermocycling. Color differences (ΔE00) and relative translucency parameter (RTP) were calculated. Data were analyzed by using ANOVA and Bonferroni-corrected t-tests (α = 0.05). ZLS had the highest load-to-failure resistance (p ≤ 0.002), while the difference between LDS and NLD was nonsignificant (p = 0.776). The interaction between material type and thickness affected ΔE00 (p < 0.001). Among the 0.7 mm thick specimens, ZLS had the lowest ΔE00 (p < 0.001). Furthermore, 1.5 mm thick ZLS had lower ΔE00 than that of 1.5 mm thick LDS (p = 0.036). Other than ZLS (p = 0.078), 0.7 mm thick specimens had higher ΔE00 (p < 0.001). The interaction between material type, thickness, and thermocycling affected RTP (p < 0.001). Thinner specimens presented higher RTP (p < 0.001). NLD and LDS had higher RTP than ZLS (p ≤ 0.036). However, 0.7 mm thick specimens had similar RTP after coffee thermocycling (p ≥ 0.265). Coffee thermocycling reduced the RTP values of 0.7 mm thick NLD (p = 0.032) and LDS (p = 0.008). NLD may endure the occlusal forces present in the posterior region. However, long-term coffee consumption may impair the esthetics of restorations particularly when thin NLD is used.
Collapse
|
7
|
Baldi A, Comba A, Ferrero G, Italia E, Michelotto Tempesta R, Paolone G, Mazzoni A, Breschi L, Scotti N. External gap progression after cyclic fatigue of adhesive overlays and crowns made with high translucency zirconia or lithium silicate. J ESTHET RESTOR DENT 2021; 34:557-564. [PMID: 34783440 PMCID: PMC9298883 DOI: 10.1111/jerd.12837] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Revised: 10/16/2021] [Accepted: 10/26/2021] [Indexed: 11/27/2022]
Abstract
OBJECTIVES To evaluate three-dimensional external gap progression after chewing simulation of high translucency zirconia (HTZ) and zirconia-reinforced lithium silicate (ZLS) applied on endodontically treated teeth with different preparation designs. MATERIALS AND METHOD Endodontically treated molars were prepared with low-retentive (adhesive overlay) and high-retentive (full crown) designs above cementum-enamel junction and restored with HTZ and ZLS. Micro-computed tomography analysis was assessed before and after chewing simulation to evaluate three-dimensionally the external gap progression. Results were statistically analyzed with two-way ANOVA and post-hoc Tukey test. RESULTS High-retentive preparation design had a significantly inferior gap progression compared to the overlay preparation (p < 0.01); ZLS exhibited a significant inferior gap progression compared to HTZ (p < 0.01). CONCLUSIONS High-retentive preparations restored with ZLS seem to better perform in maintaining the sealing of the external margin after cyclic fatigue. CLINICAL SIGNIFICANCE The clinician should pay attention to the proper combination of preparation designs and ceramic material selection for an endodontically treated molar restoration. HTZ seems to perform worse than lithium silicate in terms of marginal sealing, still showing lacks in resistance to cyclic fatigue when adhesive preparations are performed.
Collapse
Affiliation(s)
- Andrea Baldi
- Department of Surgical Sciences, Dental School Lingotto, Turin
| | - Allegra Comba
- Department of Surgical Sciences, Dental School Lingotto, Turin
| | - Giorgio Ferrero
- Department of Surgical Sciences, Dental School Lingotto, Turin
| | - Edoardo Italia
- Department of Surgical Sciences, Dental School Lingotto, Turin
| | | | - Gaetano Paolone
- Department of Dentistry, IRCCS San Raffaele Hospital and Dental School, Vita Salute University, Milan, Italy
| | - Annalisa Mazzoni
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna, Alma Mater Studiorum, Bologna, Italy
| | - Lorenzo Breschi
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna, Alma Mater Studiorum, Bologna, Italy
| | - Nicola Scotti
- Department of Surgical Sciences, Dental School Lingotto, Turin
| |
Collapse
|
8
|
Çakmak G, Donmez MB, Kashkari A, Johnston WM, Yilmaz B. Effect of thickness, cement shade, and coffee thermocycling on the optical properties of zirconia reinforced lithium silicate ceramic. J ESTHET RESTOR DENT 2021; 33:1132-1138. [PMID: 34390305 PMCID: PMC9292539 DOI: 10.1111/jerd.12808] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2021] [Revised: 07/11/2021] [Accepted: 07/28/2021] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To investigate the effect of thickness, cement shade, and coffee thermocycling (CTC) on the optical properties of zirconia reinforced lithium silicate (ZLS) paired with different shades of a resin cement. MATERIALS AND METHODS Thirty ZLS specimens were prepared in two different thicknesses (0.8 and 1.5 mm) and three different resin cement shades (Tr, A2, and A3) were applied (n = 5). Color determinations were done before and after 5000 CTC by using a noncontact spectroradiometer. Color change due to CTC and relative translucency parameter (RTP) before and after CTC were calculated by using CIEDE2000. Data were analyzed using ANOVA and Bonferroni-corrected t-tests(α = 0.05). RESULTS Material thickness and resin cement shade (P < 0.001) affected baseline color. Material thickness affected color difference (P = 0.025). Thickness, resin cement shade, and CTC (P ≤ 0.0001) affected RTP. The difference between the color changes of the 0.8- and 1.5-mm specimens combined with A2 shade cement after CTC was significant (P = 0.01). RTPs of all pairs decreased after CTC (P < 0.001). CONCLUSIONS Cement shade and material thickness affected the baseline color. The thickness of ZLS affected the color change after CTC only with A2 resin cement and the color change was less when the ZLS was thicker. CTC reduced the translucency of all pairs. CLINICAL SIGNIFICANCE Clinicians and patients should be aware of a potential color change after long-term coffee consumption when zirconia reinforced lithium silicate is used particularly for laminate veneers with A2 shade of the tested resin cement.
Collapse
Affiliation(s)
- Gülce Çakmak
- Buser Foundation Scholar for Implant Dentistry, Department of Reconstructive Dentistry and Gerodontology, School of Dental MedicineUniversity of BernBernSwitzerland
| | - Mustafa Borga Donmez
- Department of ProsthodonticsBiruni University Faculty of DentistryIstanbulTurkey
| | - Afnan Kashkari
- Restorative and Esthetic DentistryJohns Hopkins Aramco HealthcareDhahranSaudi Arabia
| | - William M. Johnston
- Division of Restorative and Prosthetic DentistryThe Ohio State University College of DentistryColumbusOhio
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental MedicineUniversity of Bern, BernSwitzerland
- Department of Restorative, Preventive and Pediatric Dentistry, School of Dental MedicineUniversity of BernBernSwitzerland
- Division of Restorative and Prosthetic DentistryThe Ohio State UniversityOhioUSA
| |
Collapse
|
9
|
Optical behaviors, surface treatment, adhesion, and clinical indications of zirconia-reinforced lithium silicate (ZLS): A narrative review. J Dent 2021; 112:103722. [PMID: 34118284 DOI: 10.1016/j.jdent.2021.103722] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 05/28/2021] [Accepted: 06/01/2021] [Indexed: 12/19/2022] Open
Abstract
OBJECTIVES The present narrative review was focused on the optical properties, surface treatment, adhesion, and clinical indications of zirconia-reinforced lithium silicate ceramics (ZLS) for Computer-aided design / Computer-aided manufacturing (CAD/CAM) technologies. DATA/SOURCES A literature search was performed by 3 calibrated independent researchers on PubMed, Scopus, Embase, Google Scholar, Dynamed, and Open Grey. The criteria for inclusion were: 1) papers addressing at least one of the following variables about ZLS: optical properties, surface treatment, adhesion, and clinical indications; 2) in vitro, in silico, or in vivo studies; 3) case reports; 4) systematic reviews. The exclusion criteria were: 1) animal studies; 2) non-dental studies; 3) studies only focusing on ZLS used in the heat-pressed process. STUDY SELECTION 98 records among in vitro studies and case reports were included. CONCLUSIONS Despite the promising microstructure characteristics of ZLS, increased translucency compared to lithium disilicate ceramics (LS2) was not proven, but acceptable color changes and stability were reported. Mechanical polishing was the most effective method to reduce surface roughness. Moreover, machinability and handling of ZLS resulted harder than LS2. Conventional acid etching procedures seemed effective in conditioning ZLS surface, but no protocol has been established yet. Besides, silane-coupling and dual-curing resin cements were recommended. CLINICAL SIGNIFICANCE ZLSs can be used for anterior and posterior fixed single-unit CAD/CAM restorations onto both natural teeth and implants, but do not seem to represent a viable treatment option for endocrowns onto posterior teeth or fixed dental prostheses.
Collapse
|
10
|
Zarone F, Ruggiero G, Leone R, Breschi L, Leuci S, Sorrentino R. Zirconia-reinforced lithium silicate (ZLS) mechanical and biological properties: A literature review. J Dent 2021; 109:103661. [PMID: 33864886 DOI: 10.1016/j.jdent.2021.103661] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 04/06/2021] [Accepted: 04/08/2021] [Indexed: 01/17/2023] Open
Abstract
OBJECTIVES This paper aimed to provide a literature review of the mechanical and biological properties of zirconia-reinforced lithium silicate glass-ceramics (ZLS) in Computer-aided design / Computer-aided manufacturing (CAD/CAM) systems. DATA/SOURCES An extensive search of the literature for papers related to ZLS was made on the databases of PubMed/Medline, Scopus, Embase, Google Scholar, Dynamed, and Open Grey. The papers were selected by 3 independent calibrated reviewers. STUDY SELECTION The search strategy produced 937 records. After the removal of duplicates and the exclusion of papers that did not meet the inclusion criteria, 71 papers were included. CONCLUSIONS After reviewing the included records, it was found that two types of ZLS (Vita Suprinity PC; Vita Zahnfabrik and Celtra Duo; Dentsply Sirona) are nowadays available on the market for CAD/CAM systems, similar in their chemical composition, microstructure, and biological-mechanical properties. ZLS is reported to be a biocompatible material, whose fracture resistance can withstand physiological chewing loads. The firing process influences the improvements of strength and fatigue failure load, with a volumetric shrinkage. To date, ZLS can be considered a viable alternative to other glass-ceramics for fixed single restorations. CLINICAL SIGNIFICANCE . As to biocompatibility and mechanical properties of ZLS, data are still scarce, often controversial and limited to short-term observational periods. These promising ceramics require further in vitro/in vivo studies to accurately define mechanical and biological properties, mainly in the long-term performance of restorations produced with such materials.
Collapse
Affiliation(s)
- Fernando Zarone
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, Division of Prosthodontics and Digital Dentistry, University "Federico II" of Naples, Via Pansini 5, 80131, Naples, Italy.
| | - Gennaro Ruggiero
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, Division of Prosthodontics and Digital Dentistry, University "Federico II" of Naples, Via Pansini 5, 80131, Naples, Italy.
| | - Renato Leone
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, Division of Prosthodontics and Digital Dentistry, University "Federico II" of Naples, Via Pansini 5, 80131, Naples, Italy.
| | - Lorenzo Breschi
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna, Alma Mater Studiorum, Via San Vitale 59, 40125, Bologna, Italy.
| | - Stefania Leuci
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, Oral Medicine Unit, School of Medicine, University "Federico II" of Naples, Via Pansini 5, 80131, Naples, Italy.
| | - Roberto Sorrentino
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, Division of Prosthodontics and Digital Dentistry, University "Federico II" of Naples, Via Pansini 5, 80131, Naples, Italy.
| |
Collapse
|
11
|
Chaturvedi S, Alqahtani T, Alsolami S, Alqahtani A, Das G, Alsubaiy E. Fracture resistance of CAD-CAM all-ceramic surveyed crowns with different occlusal rest seat designs. J Adv Prosthodont 2021; 13:36-45. [PMID: 33747393 PMCID: PMC7943750 DOI: 10.4047/jap.2021.13.1.36] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Revised: 01/21/2021] [Accepted: 02/02/2021] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To investigate the fracture resistance of monolithic CAD-CAM all-ceramic surveyed crowns with two different occlusal rest seat designs. MATERIALS AND METHODS Two maxillary first premolar were prepared for all-ceramic surveyed crowns with wide (2/3rd of buccolingual width of an unprepared tooth) or narrow (1/3rd of buccolingual width of an unprepared tooth) disto-occlusal rest seat (ORS) designs. Eighty monolithic CAD-CAM all-ceramic surveyed crowns were prepared and divided into 4 groups - Group CR, Composite resin material as a control; Group LDS, Lithium disilicate based material; Group ZIPS, zirconia-material (IPS ZirCAD); and Group ZLHT, zirconia- material (CeramillZolidht+). Crowns were cemented on an epoxy resin die with adhesive resin cement. The fracture resistance of crowns was tested with the universal machine. Univariate regression analysis was used. RESULTS The mean ± standard deviation of maximum failure force values varied from 3476.10 ± 285.97 N for the narrow ORS subgroup of group ZIPS to 687.89 ± 167.63 N for the wide ORS subgroup of group CR. The mean ± standard deviation of maximum force was 1075 ± 77.0 N for group CR, 1309.3 ± 283.9 N for group LDS, 3476.1 ± 285.97 N for group ZIPS, and 2666.7 ± 228.21 N for group ZLHT, with narrow occlusal rest seat design. The results of the intergroup comparison showed significant differences in fracture strength with various material groups and occlusal rest seat designs (P <.001). CONCLUSION The zirconia-based all-ceramic surveyed crowns fractured at more than double the load of Lithium disilicate based crowns. The crowns with narrow base occlusal rest seat design had statistically significantly higher fracture resistance than surveyed crowns with wide occlusal rest seat design. The use of narrow occlusal rest seat design in CAD-CAM all ceramic surveyed crowns provides higher fracture resistance, and therefore narrow occlusal rest design can be used for providing esthetics with high strength.
Collapse
Affiliation(s)
- Saurabh Chaturvedi
- Department of Prosthetic Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Turki Alqahtani
- Department of Prosthetic Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Saleh Alsolami
- Department of Prosthetic Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Abdulbari Alqahtani
- Department of Prosthetic Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Gotam Das
- Department of Prosthetic Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Ebrahim Alsubaiy
- Department of Prosthetic Dentistry, King Khalid University, Abha, Saudi Arabia
| |
Collapse
|
12
|
Donmez MB, Okutan Y, Yucel MT. Effect of prolonged application of single-step self-etching primer and hydrofluoric acid on the surface roughness and shear bond strength of CAD/CAM materials. Eur J Oral Sci 2020; 128:542-549. [PMID: 33247878 DOI: 10.1111/eos.12747] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Revised: 10/22/2020] [Accepted: 10/23/2020] [Indexed: 11/30/2022]
Abstract
This in vitro study aimed to assess the influence of different concentrations and durations of hydrofluoric acid (HF) and Monobond Etch & Prime (MEP) etching on the surface roughness (Ra ) of different CAD/CAM materials and on the shear bond strength (SBS) of a self-adhesive resin bonded to the materials. Seventy specimens of hybrid ceramic, leucite-based glass-ceramic, lithium disilicate glass-ceramic, and zirconia-reinforced lithium silicate glass-ceramic were prepared and divided into seven groups according to the surface treatments: Control (C); MEP etching for 60 (MEP60 ) and 120 (MEP120 ) s; 5% HF etching for 60 (HF-5%60 ) and 120 (HF-5%120 ) s; 9.5% HF etching for 60 (HF-9.5%60 ) and 120 (HF-9.5%120 ) s. The Ra was measured using a 3D profilometer. All groups were treated with a universal primer except for the C, MEP60 , and MEP120 groups. A self-adhesive resin cement was bonded to all specimens, and the bond strengths were measured using a universal testing machine. All surface treatments increased both Ra and SBS values compared to the control in each material. Neither the duration of surface treatments nor the HF acid concentrations had a statistically significant effect on SBS. Within the limitations of this experimental study, it can be concluded that Monobond Etch & Prime may be a preferable method to achieve high bond strength values.
Collapse
Affiliation(s)
- Mustafa B Donmez
- Department of Prosthodontics, Faculty of Dentistry, Biruni University, Istanbul, Turkey
| | - Yener Okutan
- Department of Prosthodontics, Faculty of Dentistry, Aydin Adnan Menderes University, Aydın, Turkey
| | - Munir T Yucel
- Department of Prosthodontics, Faculty of Dentistry, Selcuk University, Konya, Turkey
| |
Collapse
|
13
|
Rosentritt M, Preis V, Behr M, Strasser T. Fatigue and wear behaviour of zirconia materials. J Mech Behav Biomed Mater 2020; 110:103970. [DOI: 10.1016/j.jmbbm.2020.103970] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2020] [Revised: 06/29/2020] [Accepted: 07/01/2020] [Indexed: 01/10/2023]
|
14
|
Fracture Resistance of Zirconia-Reinforced Lithium Silicate Ceramic Crowns Cemented with Conventional or Adhesive Systems: An In Vitro Study. MATERIALS 2020; 13:ma13092012. [PMID: 32344894 PMCID: PMC7254201 DOI: 10.3390/ma13092012] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2020] [Revised: 04/11/2020] [Accepted: 04/23/2020] [Indexed: 12/15/2022]
Abstract
In recent years, Zirconia-reinforced Lithium Silicate ceramic (ZLS), combining lithium-silicate and zirconia features, has shown to have excellent mechanical and aesthetic characteristics. Thus, the aim of this study was to compare the fracture strength of ZLS single crowns cemented with two different cementation techniques. Twenty crowns were realised and cemented on teeth replicas achieved from an extracted premolar human tooth. The samples were divided into two groups of 10 specimens each, Glass-ionomeric cement (GIC) group and Self-Adhesive Resin Cement (ARC) group. The mechanical test was performed using a universal testing machine. The specimens were then evaluated with a scanning electron microscope (SEM) to identify for all crowns and related abutments the pattern of fracture after the breaking point. The data obtained were statistically analysed. The mean fracture toughness values and standard deviations (±SD) were 2227 ± 382 N and 3712 ± 319 N respectively for GIC and ARC groups. In fact, t-test showed a statistically significant difference between the two groups (p < 0.001). Moreover, the SEM results demonstrated portions of abutments still attached to the crown fragments in the ARC group, whilst these were not present in the GIC group. Within the limitations of this study, these results suggest the use of adhesive cementation for ZLS crowns, which significantly increase the compressive strength of ZLS restorations compared to GIC.
Collapse
|
15
|
Zarone F, Di Mauro MI, Ausiello P, Ruggiero G, Sorrentino R. Current status on lithium disilicate and zirconia: a narrative review. BMC Oral Health 2019; 19:134. [PMID: 31272441 PMCID: PMC6610968 DOI: 10.1186/s12903-019-0838-x] [Citation(s) in RCA: 160] [Impact Index Per Article: 32.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Accepted: 06/27/2019] [Indexed: 01/28/2023] Open
Abstract
Background The introduction of the new generation of particle-filled and high strength ceramics, hybrid composites and technopolymers in the last decade has offered an extensive palette of dental materials broadening the clinical indications in fixed prosthodontics, in the light of minimally invasive dentistry dictates. Moreover, last years have seen a dramatic increase in the patients’ demand for non-metallic materials, sometimes induced by metal-phobia or alleged allergies. Therefore, the attention of scientific research has been progressively focusing on such materials, particularly on lithium disilicate and zirconia, in order to shed light on properties, indications and limitations of the new protagonists of the prosthetic scene. Methods This article is aimed at providing a narrative review regarding the state-of-the-art in the field of these popular ceramic materials, as to their physical-chemical, mechanical and optical properties, as well as to the proper dental applications, by means of scientific literature analysis and with reference to the authors’ clinical experience. Results A huge amount of data, sometimes conflicting, is available today. Both in vitro and in vivo studies pointed out the outstanding peculiarities of lithium disilicate and zirconia: unparalleled optical and esthetic properties, together with high biocompatibility, high mechanical resistance, reduced thickness and favorable wear behavior have been increasingly orientating the clinicians’ choice toward such ceramics. Conclusions The noticeable properties and versatility make lithium disilicate and zirconia materials of choice for modern prosthetic dentistry, requiring high esthetic and mechanical performances combined with a minimal invasive approach, so that the utilization of such metal-free ceramics has become more and more widespread over time.
Collapse
Affiliation(s)
- Fernando Zarone
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University "Federico II" of Naples, Viale Pansini, 5 -, 80131, Naples, Italy
| | - Maria Irene Di Mauro
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University "Federico II" of Naples, Viale Pansini, 5 -, 80131, Naples, Italy.
| | - Pietro Ausiello
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University "Federico II" of Naples, Viale Pansini, 5 -, 80131, Naples, Italy
| | - Gennaro Ruggiero
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University "Federico II" of Naples, Viale Pansini, 5 -, 80131, Naples, Italy
| | - Roberto Sorrentino
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University "Federico II" of Naples, Viale Pansini, 5 -, 80131, Naples, Italy
| |
Collapse
|