Shirani M, Emami M, Mosharraf R, Savabi O, Akhavankhaleghi M, Azadbakht K. Comparing the color match of monolithic CAD-CAM dental ceramics with the VITA Classical shade guide. J Prosthet Dent 2024; 132:605-611. [PMID: 36115709 DOI: 10.1016/j.prosdent.2022.06.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 06/17/2022] [Accepted: 06/21/2022] [Indexed: 10/14/2022]
Abstract
STATEMENT OF PROBLEM Matching the shade selected and the final color of a ceramic restoration is challenging, and studies on matching monolithic ceramics to the shade selected are lacking. PURPOSE The purpose of this in vitro study was to compare the color match of monolithic lithium disilicate (LDS), zirconia-reinforced lithium silicate (ZLS), presintered zirconia-reinforced lithium silicate (PS-ZLS), polymer-infiltrated ceramic network (PICN), and multilayer zirconia with the 3 modes of the VITA Classical shade guide. MATERIAL AND METHODS This study was performed on 50 rectangular plates (14×12×1 mm) of 5 types of ceramics with A2 shade (n=10). Zirconia specimens were evaluated in 3 locations: incisal, medial, and cervical thirds. The color coordinates of the specimens of all 7 groups were measured on #3 and #8 Ivoclar Natural Die Color material by using a reflective spectrophotometer. The color coordinates of A2 VITA shade were measured in 5 modes: without backing placed in specimen holder, shade tab on the backgrounds #3 and #8, and 1-mm-thick shade tab on the backgrounds #3 and #8. The color difference of each specimen with 3 modes of A2 shade (without backing and on similar backgrounds) was calculated by using the ΔE00 formula, and comparison among groups was performed by using 2-way ANOVA and Tamhane post hoc tests. The comparison of ΔE00 between the values obtained from backgrounds #3 and #8 was performed by using the independent t test (α=.05). RESULTS In both backgrounds, statistically significant differences were found between the studied groups and VITA shade (P<.001). In most situations, the amount of color difference was lowest for the "shade tab on the backgrounds" mode. On background #3, the highest color difference was related to ZLS (6.48 ±0.23), and the lowest values were observed in the PICN group (1.02 ±0.31). On background #8, the highest color difference was related to ZLS compared with the "without backing" mode (8.62 ±0.27), and the lowest values were reported for ZLS compared with the "shade tab on the backgrounds" mode (1.27 ±0.44). The independent t test showed a statistically significant color difference on the 2 different backgrounds for all situations (P<.001). CONCLUSIONS Color selection of monolithic ceramics with the VITA Classical shade guide is improved by placing the VITA tabs on a similar background. Background color has a significant effect on the final shade of the monolithic ceramics. Choosing the correct color for LDS, ZLS, and PS-ZLS requires more care than for PICN and zirconia.
Collapse
Affiliation(s)
- Mohammadjavad Shirani
- Assistant Professor, Department of Prosthodontics, School of Dentistry, Lorestan University of Medical Sciences, Khorramabad, Iran
| | - Maryam Emami
- Instructor, Dentist, student Research Committee, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Ramin Mosharraf
- Professor of Prosthodontics, Dental Materials Research Center, Department of Prosthodontics, Dental Research Institute, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Omid Savabi
- Professor of Prosthodontics, Dental Materials Research Center, Department of Prosthodontics, Dental Research Institute, Isfahan University of Medical Sciences, Isfahan, Iran; Professor of Prosthodontics, Dental Research Center, Dental Research Institute, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Mehrdad Akhavankhaleghi
- Assistant Professor, Department of Prosthodontics, School of Dentistry, Shahrekord University of Medical Sciences, Shahrekord, Iran
| | - Kamran Azadbakht
- Assistant Professor, Department of Prosthodontics, School of Dentistry, Lorestan University of Medical Sciences, Khorramabad, Iran.
| |
Collapse
|
2
|
Roig-Vanaclocha A, Revilla-León M, Gómez-Polo M, Agustín-Panadero R. Polytetrafluoroethylene relative isolation for adhesive cementation of dental restorations. J Prosthet Dent 2024; 132:26-30. [PMID: 35934570 DOI: 10.1016/j.prosdent.2022.06.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Revised: 06/21/2022] [Accepted: 06/21/2022] [Indexed: 11/20/2022]
Abstract
Tooth isolation is essential to isolate a prepared tooth from saliva, oral humidity, and gingival fluids and facilitate the removal of excess subgingival cement in adhesive cementation procedures. However, the isolation of prepared teeth can be challenging, especially with vertical preparations. A technique for achieving relative isolation by using polytetrafluoroethylene tape is described for adhesive cementation with vertical tooth preparations.
Collapse
Affiliation(s)
- Ana Roig-Vanaclocha
- Adjunct Professor of Prosthodontic and Occlusion Unit, Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain
| | - Marta Revilla-León
- Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash; Director of Research and Digital Dentistry, Kois Center, Seattle, Wash; Adjunct Professor, Department of Prosthodontics, Tufts University, Boston, Mass
| | - Miguel Gómez-Polo
- Associate Professor, Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid, Madrid, Spain; Director of Specialist in Advanced Implant-Prosthesis Postgraduate Program, Complutense University of Madrid, Madrid, Spain.
| | - Rubén Agustín-Panadero
- Associate Professor, Prosthodontic and Occlusion Unit, Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain
| |
Collapse
|
3
|
Sarıyer S, Subaşı MG. Surface treatment, liquid, and aging effects on color and surface properties of monolithic ceramics. J Adv Prosthodont 2024; 16:174-188. [PMID: 38957290 PMCID: PMC11215038 DOI: 10.4047/jap.2024.16.3.174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2023] [Revised: 05/25/2024] [Accepted: 06/09/2024] [Indexed: 07/04/2024] Open
Abstract
PURPOSE The purpose of this study was to investigate the effects of surface treatments, liquids, and aging on color, translucency, and surface properties of monolithic ceramics. MATERIALS AND METHODS Lithium disilicate (LDS) and zirconia-reinforced lithium silicate (ZLS) ceramics (n = 135 each) were cut and divided into three groups [crystallization+glaze (single stage), crystallization-glaze (two stages), and crystallization-polish (two stages)]. One sample from each group was examined using scanning electron microscopy (SEM). Remaining samples were divided into four subgroups (distilled water, coffee, grape juice, and smoothie) (n = 11 each), stored for 12 d in the respective liquids, and thermally aged. One sample from each subgroup was analyzed using SEM. The color, gloss, and roughness values of the samples were analyzed after surface treatment (initial) and storage under different liquids+aging conditions. The initial data and both the aged data and data change values were analyzed using robust two- and three-way analyses of variance. RESULTS The glazed groups exhibited smoother surfaces. Ceramic type and ceramic-surface treatment interactions affected the initial translucency parameter (TP) (P < .001) and the initial and aged roughness values (P ≤ .001). Surface treatment type affected the color change (P < .001), and ceramic type affected the aged TP values (P < .001). Type of ceramic, surface treatment, and their interactions affected both the initial and aged gloss (P ≤ .001) and TP change values (P ≤ .015). Surface treatment type and ceramic-surface treatment interactions affected the gloss change values (P ≤ .001). CONCLUSION Although both ceramics and all surface treatments are clinically applicable, crystallization-glaze is recommended. When gloss and smoothness are important or when translucency is important, ZLS or LDS may be preferred, respectively.
Collapse
Affiliation(s)
- Sertaç Sarıyer
- Department of Prosthodontics, Faculty of Dentistry, Kutahya Health Sciences University, Kütahya, Turkey
| | - Meryem Gülce Subaşı
- Department of Prosthodontics, Faculty of Dentistry, Kutahya Health Sciences University, Kütahya, Turkey
| |
Collapse
|
4
|
Benalcazar-Jalkh EB, Cunha VS, Bergamo ETP, Alves LMM, de Monteiro-Sousa RS, Campos TMB, Tanaka R, Marcolino GDA, Souza FMD, Bonfante EA. Finishing technique effect on strength of zirconia-reinforced lithium silicate ceramic. Eur J Oral Sci 2024; 132:e12964. [PMID: 38062529 DOI: 10.1111/eos.12964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2023] [Accepted: 11/14/2023] [Indexed: 01/25/2024]
Abstract
The aim of this study was to evaluate the effect of two finishing techniques, glazing or polishing, in comparison with the as-cut condition, on the biaxial-flexural-strength (BFS) of a zirconia-reinforced lithium silicate ceramic (ZLS). Cylinders were milled from CAD/CAM blocks and sliced to obtain disc-shaped specimens (ISO6872:2015). Polished and glazed specimens were processed following the manufacturer's instructions. Thirty-three specimens were obtained for each condition and microstructural and BFS/fractographic characterizations were performed. BFS and roughness data were analyzed using Weibull statistics and ANOVA one-way with Tukey post-hoc test, respectively. While a rougher surface was observed for as-cut specimens, smoother surfaces were observed for polished and glazed ZLS at microscopical evaluation and confirmed through surface-roughness evaluation. X-ray spectra depicted a glass phase for all groups and characteristic metasilicate, lithium disilicate, and lithium phosphate peaks for the as-cut and polished specimens. Glazed specimens showed higher characteristic strength than polished and as-cut specimens, which did not differ significantly. While higher Weibull-modulus was observed for the polished than for the as-cut specimens, no statistically significant differences were noted between glazed and polished, and between glazed and as-cut specimens. ZLS presents higher strength when glazed, and polishing increases the structural reliability of the material relative to the as-cut condition. Both finishing techniques reduced surface roughness similarly.
Collapse
Affiliation(s)
| | - Verena Souza Cunha
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Sao Paulo, Brazil
| | - Edmara Tatiely Pedroso Bergamo
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Sao Paulo, Brazil
- Biomaterials Division, NYU Dentistry, New York, USA
- Department of Prosthodontics, NYU Dentistry, New York, USA
| | - Larissa Marcia Martins Alves
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Sao Paulo, Brazil
| | | | - Tiago Moreira Bastos Campos
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Sao Paulo, Brazil
| | | | - Giovana de Assis Marcolino
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Sao Paulo, Brazil
| | - Felipe Machado de Souza
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Sao Paulo, Brazil
| | - Estevam Augusto Bonfante
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Sao Paulo, Brazil
| |
Collapse
|
5
|
Wu Z, Wei D, Tian J, Zhang Y, Lin Y, Di P. Quantitative analysis of the color in six CAD-CAM dental materials of varied thickness and surface roughness: An in vitro study. J Prosthet Dent 2024; 131:292.e1-292.e9. [PMID: 37978004 DOI: 10.1016/j.prosdent.2023.10.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 10/27/2023] [Accepted: 10/27/2023] [Indexed: 11/19/2023]
Abstract
STATEMENT OF PROBLEM Computer-aided design and computer-aided manufacturing (CAD-CAM) monochromatic restorative materials are gaining popularity because of their convenience and efficiency. However, studies that quantitatively analyzed color change associated with thickness and surface roughness are sparse. PURPOSE The purpose of this in vitro study was to quantitatively evaluate the color of 6 CAD-CAM monochromatic materials of different thickness and surface roughness using the CIELab color system. MATERIAL AND METHODS A total of 150 12×12-mm square specimens of 6 different CAD-CAM monochromatic materials (VITA Enamic HT [VE], IPS e.max CAD HT [LS], LAVA Ultimate HT [LU], Telio CAD HT [TE], VITA Suprinity HT [VS], and Celtra Duo HT [CD]) in shade A2 and 5 different thicknesses (from 0.5 mm to 2.5 mm, with 0.5-mm increments) were fabricated (n=5). After 3 different surface treatments (polished, roughened by SiC P800-grit, and P300-grit), CIELab color parameters (L*, a* and b*) were measured using a spectrophotometer (VITA Easyshade V), and surface roughness was measured with a profilometer (VK-X200). Color variation was quantified by ΔE00 and 50:50% acceptability and perceptibly thresholds. Data analyses were performed using MANOVA, 2-way ANOVA, post hoc Tukey-Kramer test, and the 1-sample t test (α=.05). RESULTS The L*, a*, and b* of the monochromatic specimens were significantly influenced by material type, thickness, and surface roughness (P<.001). An overall increase in the L* (from 61.90 to 82.2), a* (from -4.22 to 1.16), and b* (from 5.48 to 43.22) of the specimens was observed with increased thickness. The roughened specimens exhibited lower L* and higher a* and b* than the polished ones (P<.001). The use of P300-grit for roughening resulted in greater ΔE00 compared with P800-grit (P<.001). As thickness decreased or surface roughness increased, the ΔE00 increased and exceeded the acceptability and perceptibly thresholds for color difference. CONCLUSIONS Material type, thickness, and surface roughness were major factors affecting the color of CAD-CAM monochromatic materials. Variations in thickness of 0.5 mm or more, as well as roughening treatments, may lead to clinically unacceptable color changes.
Collapse
Affiliation(s)
- Zhengda Wu
- Lecturer, Department of Oral Implantology, Peking University School and Hospital of Stomatology, Beijing, PR China
| | - Donghao Wei
- Lecturer, Department of Oral Implantology, Peking University School and Hospital of Stomatology, Beijing, PR China
| | - Jiehua Tian
- Lecturer, Department of Oral Implantology, Peking University School and Hospital of Stomatology, Beijing, PR China
| | - Yifan Zhang
- Lecturer, Department of Oral Implantology, Peking University School and Hospital of Stomatology, Beijing, PR China
| | - Ye Lin
- Professor, Department of Oral Implantology, Peking University School and Hospital of Stomatology, Beijing, PR China
| | - Ping Di
- Professor, Department of Oral Implantology, Peking University School and Hospital of Stomatology, Beijing, PR China.
| |
Collapse
|
6
|
Diken Türksayar AA, Demirel M, Donmez MB. Optical properties, biaxial flexural strength, and reliability of new-generation lithium disilicate glass-ceramics after thermal cycling. J Prosthodont 2023; 32:815-820. [PMID: 36585789 DOI: 10.1111/jopr.13632] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 11/24/2022] [Accepted: 12/16/2022] [Indexed: 01/01/2023] Open
Abstract
PURPOSE To investigate the color stability, translucency, biaxial flexural strength (BFS), and reliability of nano-lithium disilicate and fully crystallized lithium disilicate after thermal cycling and to compare with those of a commonly used lithium disilicate. MATERIALS AND METHODS Three lithium disilicate glass-ceramics were used to prepare disk-shaped specimens (ø:12 mm, thickness: 1.2 mm) from A2 shaded HT blocks (Amber Mill, AM; Initial LiSi Block, IN; IPS e.max CAD, EX). AM and EX specimens were crystallized, and all specimens were polished with a polishing paste (Diamond Polish Mint). A spectrophotometer (CM-26d) was used to measure color coordinates before and after thermal cycling. BFS test was performed after thermal cycling. Color differences (ΔE00 ) and relative translucency parameter (RTP) values were calculated. One-way analysis of variance (ANOVA) (ΔE00 and BFS), two-way ANOVA followed by Tukey's HSD tests (RTP), and chi-square tests (Weibull modulus and characteristic strength) were used for the statistical analyses (α = 0.05). RESULTS No significant differences were observed among the ΔE00 values of tested materials (df = 2, F = 2.933, p = 0.070). RTP values were only affected by material type (p < 0.001) as AM had the highest RTP (p < 0.001), whereas IN and EX had similar values (p ≥ 0.165). BFS values varied among tested materials (df = 2, F = 21.341, p < 0.001). AM and EX had similar BFS values (p = 0.067) that were higher than that of IN (p ≤ 0.001). Weibull moduli of the materials were similar (p = 0.305), whereas EX had the highest and IN had the lowest characteristic strength values (p < 0.001) CONCLUSIONS: Although nano-lithium disilicate had the highest translucency, all materials had imperceptible color and translucency changes after thermal cycling when reported threshold values were considered. Newly introduced lithium disilicate glass-ceramics had adequate flexural strength as compared to the precursor material.
Collapse
Affiliation(s)
- Almira Ada Diken Türksayar
- Department of Prosthodontics, Faculty of Dentistry, Biruni University, İstanbul, Turkey
- ADMiRE Research Center-Additive Manufacturing, Intelligent Robotics, Sensors and Engineering, School of Engineering and IT, Carinthia University of Applied Sciences, Villach, Austria
| | - Münir Demirel
- Oral and Dental Health, Vocational School, Biruni University, İstanbul, Turkey
| | - Mustafa Borga Donmez
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| |
Collapse
|
7
|
Jurado CA, Arndt K, Azpiazu-Flores FX, Faddoul F, França R, Fischer NG, Watanabe H. Evaluation of Glazing and Polishing Systems for Novel Chairside CAD/CAM Lithium Disilicate and Virgilite Crowns. Oper Dent 2023; 48:689-699. [PMID: 37881035 DOI: 10.2341/23-017-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/06/2023] [Indexed: 10/27/2023]
Abstract
OBJECTIVE The purpose of this study was to evaluate the effectiveness of glazing, two zirconia, and two lithium disilicate polishing systems on surface roughness of a CAD/CAM lithium disilicate and virgilite ceramic with atomic force microscopy (AFM) and visual assessment performed by dental students and faculty. METHODS AND MATERIALS Sixty maxillary right central incisor crowns made of a novel chairside CAD/CAM lithium disilicate and virgilite (CEREC Tessera) were milled for glazing and polishing. The crowns were divided into six groups: no polishing/glazing provided (NoP/G); glazed (GZ); glazed and polished with Brasseler Dialite LD Lithium Disilicate (DiLD); glazed and polished with Meisinger Luster Lithium Disilicate (LuLD); glazed and polished with Brasseler Dialite ZR Zirconia (DiZR); and glazed and polished with Meisinger Luster Zirconia (LuZR). Surfaces were scanned with AFM to measure roughness (Ra) and root mean square roughness (Rq) and generate micrographs. Crowns were visually assessed by 10 dental students and 10 dental school faculty members to determine clinical acceptableness. RESULTS Glazing and all polishing kits significantly reduced Ra and Rq compared to no polishing/glazing. No significant Ra differences were found between glazing and all polishing kits (p>0.05). DiZR significantly reduced Rq compared to other groups (p<0.05). Visual assessment showed that GZ, LuLD, and DiZR were the most clinically acceptable crowns. CONCLUSION Polishing and glazing considerably improve the surface smoothness of maxillary central incisor crowns fabricated out of a chairside CAD/CAM lithium disilicate and virgilite ceramic. Altogether, zirconia polishing systems provided smoother and more clinically acceptable surfaces than the lithium disilicate kits.
Collapse
Affiliation(s)
- C A Jurado
- Carlos A Jurado, DDS, MS, associate professor, Department of Prosthodontics, The University of Iowa College of Dentistry and Dental Clinics, Iowa City, Iowa, USA
| | - K Arndt
- Katlyn Arndt, BS, dental student, Texas Tech University Health Sciences Center El Paso, Woody L Hunt School of Dental Medicine, El Paso, Texas, USA
| | - F X Azpiazu-Flores
- Francisco X Azpiazu-Flores, DDS, MS, assistant professor, University of Manitoba, Gerald Niznick College of Dentistry, Winnipeg, Manitoba, Canada; ITI Scholar at the Implant Center and Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, IN, USA
| | - F Faddoul
- Fady Faddoul, DDS, MSD, associate dean, Clinical Affairs, Texas Tech University Health Sciences Center El Paso, Woody L Hunt School of Dental Medicine, El Paso, Texas, USA
| | - R França
- Rodrigo França, DDS, MS, PhD, associate professor, University of Manitoba, Gerald Niznick College of Dentistry, Winnipeg, Manitoba, Canada
| | - N G Fischer
- *Nicholas G Fischer, PhD, fellow, Minnesota Dental Research Center for Biomaterials and Biomechanics, University of Minnesota School of Dentistry, Minneapolis, Minnesota, USA
| | - H Watanabe
- Hidehiko Watanabe, DDS, MS, professor, Department of Restorative Dentistry, Oregon Health and Sciences University School of Dentistry, Portland, Oregon, USA
| |
Collapse
|
8
|
Vichi A, Zhao Z, Mutahar M, Paolone G, Louca C. Translucency of Lithium-Based Silicate Glass-Ceramics Blocks for CAD/CAM Procedures: A Narrative Review. MATERIALS (BASEL, SWITZERLAND) 2023; 16:6441. [PMID: 37834578 PMCID: PMC10573117 DOI: 10.3390/ma16196441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 09/20/2023] [Accepted: 09/21/2023] [Indexed: 10/15/2023]
Abstract
Amid chairside CAD/CAM materials, the use of lithium-based silicate glass-ceramics (LSGC) has been steadily increasing. This review aims to report on the translucency of these materials and the variables used to measure it. An electronic search was performed within the PubMed database within the period between 2 June 2011 and 11 September 2022. English-language papers investigating the translucency of IPS e.max CAD, Celtra Duo, Suprinity PC, Initial LiSi Block, Amber Mill, N!ce, and CEREC Tessera LSGC CAD/blocks were included in the search strategy. After an initial retrieval of 160 papers, the application of exclusion criteria, and the screening of abstracts and then of full texts, 33 papers were included in the study. The retrieved materials, with different degrees of translucency (LT, HT), were IPS e.max CAD (n = 33), Suprinity PC (n = 8), and Celtra Duo (n = 1). Concerning the examined colors, the most used was A2 (n = 20), followed by A1 (n = 8) and A3 (n = 2). The translucency parameter (TP) was the most used method (n = 30) with respect to the contrast ratio (CR) (n = 11) to assess translucency. Five papers measured both. Several specimens' thicknesses (0.5-4 mm) were investigated, with 1 mm (n = 23) being the most frequently analyzed. While a general tendency could be identified, conflicting results among different papers were reported.
Collapse
Affiliation(s)
- Alessandro Vichi
- Dental Academy, University of Portsmouth, Portsmouth PO1 2QG, UK (C.L.)
| | - Zejiao Zhao
- Dental Academy, University of Portsmouth, Portsmouth PO1 2QG, UK (C.L.)
| | - Mahdi Mutahar
- Dental Academy, University of Portsmouth, Portsmouth PO1 2QG, UK (C.L.)
| | - Gaetano Paolone
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute University, 20132 Milan, Italy
| | - Chris Louca
- Dental Academy, University of Portsmouth, Portsmouth PO1 2QG, UK (C.L.)
| |
Collapse
|
9
|
Wu Z, Tian J, Wei D, Zhang Y, Lin Y, Di P. Effects of thickness and polishing treatment on the translucency and opalescence of six dental CAD-CAM monolithic restorative materials: an in vitro study. BMC Oral Health 2023; 23:579. [PMID: 37598167 PMCID: PMC10440033 DOI: 10.1186/s12903-023-03299-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Accepted: 08/10/2023] [Indexed: 08/21/2023] Open
Abstract
BACKGROUND Computer-aided design and computer-aided manufacturing (CAD-CAM) materials for prosthetic is gaining popularity in dentistry. However, limited information exists regarding the impact of thickness and roughening treatment on the optical properties of contemporary CAD-CAM restorative materials. This study aimed to quantitatively evaluate the translucency and opalescence of six dental CAD-CAM materials in response to different thicknesses and roughening treatments. METHODS Six dental CAD-CAM materials, lithium disilicate glass-ceramic (IPS e.max CAD, LS), polymer-infiltrated ceramic (VITA Enamic, VE), resin-nano ceramic glass-ceramic (LAVA Ultimate, LU), polymethyl methacrylate (Telio CAD, TE), and two zirconia reinforced lithium silicate (VITA Suprinity, VS, and Celtra Duo, CD), in shade A2 were prepared as 12 × 12mm2 specimens of four thicknesses (0.5mm, 1.0mm, 1.5mm, and 2.0mm) (N = 240, n = 10). After three different treatments (polished, roughened by SiC P800-grit, and SiC P300-grit), the translucency parameter (TP00) and opalescence parameter (OP) were measured with a spectrophotometer (VITA Easyshade V). The surface roughness was analyzed with a shape measurement laser microscope. The data were analyzed using a MANOVA, post hoc Tukey-Kramer test, the t test, and regression analysis (α = .05). RESULTS The TP00 and OP were significantly influenced by material type, thickness and roughening treatment (P < .05). TP00 showed a continues decline with increasing thicknesses, while the variations of OP were material-dependent. TP00 ranged from 37.80 (LS in 0.5mm) to 5.66 (VS in 2.0mm), and OP ranged from 5.66 (LU in 0.5mm) to 9.55 (VS in 0.5mm). The variations in TP00 of all materials between adjacent thicknesses ranged from 2.10 to 15.29, exceeding the acceptable translucency threshold except for LU. Quadratic and logarithmic regression curves exhibited the best fit for TP00 among the materials. Compared to polished specimens, rougher specimens exhibited lower TP00 and higher OP in all materials except for LS (P < 0.05). Roughening with P300-grit decreased TP00 and OP by an average of 2.59 and 0.43 for 0.5mm specimens, and 1.26 and 0.25 for 2.0mm specimens, respectively. CONCLUSIONS Variations in translucency caused by thickness and roughening treatment were perceptible and may be clinically unacceptable. Careful consideration should be given to the selection of CAD-CAM materials based on their distinct optical properties.
Collapse
Affiliation(s)
- Zhengda Wu
- Department of Implantology, Peking University School and Hospital of Stomatology, 22 South Zhongguancun Avenue, Haidian District, Beijing, 100081, China
| | - Jiehua Tian
- Department of Implantology, Peking University School and Hospital of Stomatology, 22 South Zhongguancun Avenue, Haidian District, Beijing, 100081, China
| | - Donghao Wei
- Department of Implantology, Peking University School and Hospital of Stomatology, 22 South Zhongguancun Avenue, Haidian District, Beijing, 100081, China
| | - Yifan Zhang
- Department of Implantology, Peking University School and Hospital of Stomatology, 22 South Zhongguancun Avenue, Haidian District, Beijing, 100081, China
| | - Ye Lin
- Department of Implantology, Peking University School and Hospital of Stomatology, 22 South Zhongguancun Avenue, Haidian District, Beijing, 100081, China
| | - Ping Di
- Department of Implantology, Peking University School and Hospital of Stomatology, 22 South Zhongguancun Avenue, Haidian District, Beijing, 100081, China.
| |
Collapse
|
10
|
Accuracy of four recent intraoral scanners with respect to two different ceramic surfaces. J Dent 2023; 130:104414. [PMID: 36640842 DOI: 10.1016/j.jdent.2023.104414] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Revised: 12/09/2022] [Accepted: 01/09/2023] [Indexed: 01/13/2023] Open
Abstract
OBJECTIVES To investigate the complete arch accuracy of intraoral scanners (IOS) on two different ceramic surfaces. METHODS Two maxillary master cast samples were prepared. The bases of both the master casts were made from zirconium oxide. The difference between the two casts was that the teeth of the [ZR] cast were produced from zirconium oxide and that of the [LD] cast were made of lithium disilicate glass-ceramic. Unlike the zirconia teeth of the [ZR] cast, the lithium disilicate teeth of the [LD] cast were glazed. The two master casts were digitized using a high-resolution scanner (Atos Compact Scan 5 M, GOM GmbH, Braunschweig, Germany) to obtain digital reference casts. Subsequently, each master cast was scanned 15 times using four IOSs. The IOSs were the Cerec Omnicam [OM], Primescan [PR], Trios 4 [TR4], and VivaScan [VS]. On surface comparison, the absolute mean deviation values were obtained for trueness and precision. For multiple comparisons, statistically significant differences were analyzed using one-way ANOVA and the Kruskal-Wallis H test. The p-value was adjusted to control for the increased risk of type I error (p < 0.0083). To compare the two means, the t-test and Mann-Whitney U test were used (p < 0.05). RESULTS Trueness values for [ZR] ranged from 24.6 (±6.3) µm for [PR] and 77.1 (±8.3) µm for [OM]. Trueness values for [LD] were between 28.3 (±6.3) µm for [PR] and 72.8 (±15.6) µm for [OM]. Precision values for [ZR] ranged from 17.6 (±3.7) µm for [PR] to 37.3 (±9.9) µm for [OM]. Precision values for [LD] ranged from 17.5 (±3.6) µm for [PR] to 41.8 (±8.7) µm for [OM]. Statistically significant differences were found among all the IOSs (p < 0.0083). The trueness values of the four IOSs did not differ significantly (p < 0.05) with respect to either the [ZR] or [LD] cast. The precision values of [OM] and [VS] differed significantly with respect to the scanned surface. CONCLUSIONS Complete arch scans achieved with the four IOSs showed significantly different trueness and precision results. [VS] and [OM] were more sensitive in terms of the scanned material. CLINICAL SIGNIFICANCE The latest IOSs showed the required accuracy for complete arch digital impressions in-vitro investigations. These findings should be implemented under conditions relevant to complete arch deviations, such as the construction of occlusal splints, analysis of occlusal relationships, and long-span restorations. Clinicians should be aware that the clinically acceptable threshold varies depending on the purpose of the IOS.
Collapse
|
11
|
Bonfante EA, Calamita M, Bergamo ETP. Indirect restorative systems-A narrative review. J ESTHET RESTOR DENT 2023; 35:84-104. [PMID: 36688803 DOI: 10.1111/jerd.13016] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 01/03/2023] [Accepted: 01/04/2023] [Indexed: 01/24/2023]
Abstract
OBJECTIVE The background and clinical understanding of the properties of currently available indirect restorative systems and fabrication methods is, along with manufacturer and evidence-based literature, an important starting point to guide the clinical selection of materials for tooth and/or implant supported reconstructions. Therefore, this review explores most indirect restorative systems available in the market, especially all-ceramic, along with aspects of manufacturing process, clinical survival rates, and esthetic outcomes. OVERVIEW Progressive incorporation of new technologies in the dental field and advancements in materials science have enabled the development/improvement of indirect restorative systems and treatment concepts in oral rehabilitation, resulting in reliable and predictable workflows and successful esthetic and functional outcomes. Indirect restorative systems have evolved from metal ceramics and polymers to glass ceramics, polycrystalline ceramics, and resin-matrix ceramics, aiming to improve not only biological and mechanical properties, but especially the optical properties and esthetic quality of the reconstructions, in attempt to mimic natural teeth. CONCLUSIONS Based on several clinical research, materials, and patient-related parameters, a decision tree for the selection of indirect restorative materials was suggested to guide clinicians in the rehabilitation process. CLINICAL SIGNIFICANCE The pace of materials development is faster than that of clinical research aimed to support their use. Since no single material provides an ideal solution to every case, professionals must continuously seek information from well designed, long-term clinical trials in order to incorporate or not new materials and technological advancements.
Collapse
Affiliation(s)
- Estevam A Bonfante
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry - University of São Paulo, Bauru, SP, Brazil
| | - Marcelo Calamita
- Department of Restorative Dental Sciences at the University of Florida, Gainesville, Florida, USA
| | - Edmara T P Bergamo
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry - University of São Paulo, Bauru, SP, Brazil
| |
Collapse
|