1
|
Liu N, Jiang J, Liu T, Chen H, Jiang N. Compositional, Structural, and Biomechanical Properties of Three Different Soft Tissue-Hard Tissue Insertions: A Comparative Review. ACS Biomater Sci Eng 2024; 10:2659-2679. [PMID: 38697939 DOI: 10.1021/acsbiomaterials.3c01796] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/05/2024]
Abstract
Connective tissue attaches to bone across an insertion with spatial gradients in components, microstructure, and biomechanics. Due to regional stress concentrations between two mechanically dissimilar materials, the insertion is vulnerable to mechanical damage during joint movements and difficult to repair completely, which remains a significant clinical challenge. Despite interface stress concentrations, the native insertion physiologically functions as the effective load-transfer device between soft tissue and bone. This review summarizes tendon, ligament, and meniscus insertions cross-sectionally, which is novel in this field. Herein, the similarities and differences between the three kinds of insertions in terms of components, microstructure, and biomechanics are compared in great detail. This review begins with describing the basic components existing in the four zones (original soft tissue, uncalcified fibrocartilage, calcified fibrocartilage, and bone) of each kind of insertion, respectively. It then discusses the microstructure constructed from collagen, glycosaminoglycans (GAGs), minerals and others, which provides key support for the biomechanical properties and affects its physiological functions. Finally, the review continues by describing variations in mechanical properties at the millimeter, micrometer, and nanometer scale, which minimize stress concentrations and control stretch at the insertion. In summary, investigating the contrasts between the three has enlightening significance for future directions of repair strategies of insertion diseases and for bioinspired approaches to effective soft-hard interfaces and other tough and robust materials in medicine and engineering.
Collapse
Affiliation(s)
- Nian Liu
- West China School of Stomatology, Sichuan University, Chengdu, Sichuan 610207, China
| | - Jialing Jiang
- West China School of Stomatology, Sichuan University, Chengdu, Sichuan 610207, China
| | - Tiancheng Liu
- West China Hospital, Sichuan University, Chengdu, Sichuan 610207, China
| | - Haozhe Chen
- State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan 610041, China
| | - Nan Jiang
- State Key Laboratory of Oral Diseases, & National Clinical Research Center for Oral Disease, & West China Hospital of Stomatology and the Research Center for Nano Biomaterials, Analytical & Testing Center, Sichuan University, Chengdu, Sichuan 610041, China
| |
Collapse
|
2
|
Nyland J, Sirignano MN, Richards J, Krupp RJ. Regenerative Anterior Cruciate Ligament Healing in Youth and Adolescent Athletes: The Emerging Age of Recovery Science. J Funct Morphol Kinesiol 2024; 9:80. [PMID: 38804446 PMCID: PMC11130880 DOI: 10.3390/jfmk9020080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 04/15/2024] [Accepted: 04/19/2024] [Indexed: 05/29/2024] Open
Abstract
Anterior cruciate ligament (ACL) injuries mainly arise from non-contact mechanisms during sport performance, with most injuries occurring among youth or adolescent-age athletes, particularly females. The growing popularity of elite-level sport training has increased the total volume, intensity and frequency of exercise and competition loading to levels that may exceed natural healing capacity. Growing evidence suggests that the prevailing mechanism that leads to non-contact ACL injury from sudden mechanical fatigue failure may be accumulated microtrauma. Given the consequences of primary ACL injury on the future health and quality of life of youth and adolescent athletes, the objective of this review is to identify key "recovery science" factors that can help prevent these injuries. Recovery science is any aspect of sports training (type, volume, intensity, frequency), nutrition, and sleep/rest or other therapeutic modalities that may prevent the accumulated microtrauma that precedes non-contact ACL injury from sudden mechanical fatigue failure. This review discusses ACL injury epidemiology, current surgical efficacy, the native ACL vascular network, regional ACL histological complexities such as the entheses and crimp patterns, extracellular matrix remodeling, the concept of causal histogenesis, exercise dosage and ligament metabolism, central nervous system reorganization post-ACL rupture, homeostasis regulation, nutrition, sleep and the autonomic nervous system. Based on this information, now may be a good time to re-think primary ACL injury prevention strategies with greater use of modified sport training, improved active recovery that includes well-planned nutrition, and healthy sleep patterns. The scientific rationale behind the efficacy of regenerative orthobiologics and concomitant therapies for primary ACL injury prevention in youth and adolescent athletes are also discussed.
Collapse
Affiliation(s)
- John Nyland
- Norton Orthopedic Institute, 9880 Angie’s Way, Suite 250, Louisville, KY 40241, USA (J.R.); (R.J.K.)
| | | | | | | |
Collapse
|
3
|
Wang H, He K, Cheng CK. The Structure, Biology, and Mechanical Function of Tendon/Ligament-Bone Interfaces. TISSUE ENGINEERING. PART B, REVIEWS 2024. [PMID: 38323564 DOI: 10.1089/ten.teb.2023.0295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/08/2024]
Abstract
After tendon or ligament reconstruction, the interface between the hard bone and soft connective tissue is considerably weakened and is difficult to restore through healing. The tendon/ligament-bone interface is mechanically the weakest point under tensile loading and is often the source of various postoperative complications, such as bone resorption and graft laxity. A comprehensive understanding of the macro- and microfeatures of the native tendon/ligament-bone interface would be beneficial for developing strategies for regenerating the tissue. This article discusses the structural, biological, and mechanical features of the tendon/ligament-bone interfaces and how these can be affected by aging and loading conditions.
Collapse
Affiliation(s)
- Huizhi Wang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Engineering Research Center for Digital Medicine of the Ministry of Education, Shanghai Jiao Tong University, Shanghai, China
- Center for Intelligent Medical Equipment and Devices, Institute for Innovative Medical Devices, University of Science and Technology of China, Hefei, China
- Suzhou Institute for Advanced Research, University of Science and Technology of China, Suzhou, China
| | - Kaixin He
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Engineering Research Center for Digital Medicine of the Ministry of Education, Shanghai Jiao Tong University, Shanghai, China
| | - Cheng-Kung Cheng
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Engineering Research Center for Digital Medicine of the Ministry of Education, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
4
|
Buss DJ, Rechav K, Reznikov N, McKee MD. Mineral tessellation in mouse enthesis fibrocartilage, Achilles tendon, and Hyp calcifying enthesopathy: A shared 3D mineralization pattern. Bone 2023:116818. [PMID: 37295663 DOI: 10.1016/j.bone.2023.116818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 05/17/2023] [Accepted: 06/01/2023] [Indexed: 06/12/2023]
Abstract
The hallmark of enthesis architecture is the 3D compositional and structural gradient encompassing four tissue zones - tendon/ligament, uncalcified fibrocartilage, calcified fibrocartilage and bone. This functional gradient accommodates the large stiffness differential between calcified bone and uncalcified tendon/ligament. Here we analyze in 3D the organization of the mouse Achilles enthesis and mineralizing Achilles tendon in comparison to lamellar bone. We use correlative, multiscale high-resolution volume imaging methods including μCT with submicrometer resolution and FIB-SEM tomography (both with deep learning-based image segmentation), and TEM and SEM imaging, to describe ultrastructural features of physiologic, age-related and aberrant mineral patterning. We applied these approaches to murine wildtype (WT) Achilles enthesis tissues to describe in normal calcifying fibrocartilage a crossfibrillar mineral tessellation pattern similar to that observed in lamellar bone, but with greater variance in mineral tesselle morphology and size. We also examined Achilles enthesis structure in Hyp mice, a murine model for the inherited osteomalacic disease X-linked hypophosphatemia (XLH) with calcifying enthesopathy. In Achilles enthesis fibrocartilage of Hyp mice, we show defective crossfibrillar mineral tessellation similar to that which occurs in Hyp lamellar bone. At the cellular level in fibrocartilage, unlike in bone where enlarged osteocyte mineral lacunae are found as peri-osteocytic lesions, mineral lacunar volumes for fibrochondrocytes did not differ between WT and Hyp mice. While both WT and Hyp aged mice demonstrate Achilles tendon midsubstance ectopic mineralization, a consistently defective mineralization pattern was observed in Hyp mice. Strong immunostaining for osteopontin was observed at all mineralization sites examined in both WT and Hyp mice. Taken together, this new 3D ultrastructural information describes details of common mineralization trajectories for enthesis, tendon and bone, which in Hyp/XLH are defective.
Collapse
Affiliation(s)
- Daniel J Buss
- Department of Anatomy and Cell Biology, School of Biomedical Sciences, Faculty of Medicine and Health Sciences, McGill University, Montreal, Quebec, Canada
| | - Katya Rechav
- Electron Microscopy Unit, Weizmann Institute of Science, Rehovot, Israel
| | - Natalie Reznikov
- Department of Anatomy and Cell Biology, School of Biomedical Sciences, Faculty of Medicine and Health Sciences, McGill University, Montreal, Quebec, Canada; Department of Bioengineering, Faculty of Engineering, McGill University, Montreal, Quebec, Canada; Faculty of Dental Medicine and Oral Health Sciences, McGill University, Montreal, Quebec, Canada
| | - Marc D McKee
- Department of Anatomy and Cell Biology, School of Biomedical Sciences, Faculty of Medicine and Health Sciences, McGill University, Montreal, Quebec, Canada; Faculty of Dental Medicine and Oral Health Sciences, McGill University, Montreal, Quebec, Canada.
| |
Collapse
|
5
|
Gögele C, Vogt J, Hahn J, Breier A, Bernhardt R, Meyer M, Schröpfer M, Schäfer-Eckart K, Schulze-Tanzil G. Co-Culture of Mesenchymal Stem Cells and Ligamentocytes on Triphasic Embroidered Poly(L-lactide-co-ε-caprolactone) and Polylactic Acid Scaffolds for Anterior Cruciate Ligament Enthesis Tissue Engineering. Int J Mol Sci 2023; 24:ijms24076714. [PMID: 37047686 PMCID: PMC10095212 DOI: 10.3390/ijms24076714] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 03/26/2023] [Accepted: 03/28/2023] [Indexed: 04/07/2023] Open
Abstract
Successful anterior cruciate ligament (ACL) reconstructions strive for a firm bone-ligament integration. With the aim to establish an enthesis-like construct, embroidered functionalized scaffolds were colonized with spheroids of osteogenically differentiated human mesenchymal stem cells (hMSCs) and lapine (l) ACL fibroblasts in this study. These triphasic poly(L-lactide-co-ε-caprolactone) and polylactic acid (P(LA-CL)/PLA) scaffolds with a bone-, a fibrocartilage transition- and a ligament zone were colonized with spheroids directly after assembly (DC) or with 14-day pre-cultured lACL fibroblast and 14-day osteogenically differentiated hMSCs spheroids (=longer pre-cultivation, LC). The scaffolds with co-cultures were cultured for 14 days. Cell vitality, DNA and sulfated glycosaminoglycan (sGAG) contents were determined. The relative gene expressions of collagen types I and X, Mohawk, Tenascin C and runt-related protein (RUNX) 2 were analyzed. Compared to the lACL spheroids, those with hMSCs adhered more rapidly. Vimentin and collagen type I immunoreactivity were mainly detected in the hMSCs colonizing the bone zone. The DNA content was higher in the DC than in LC whereas the sGAG content was higher in LC. The gene expression of ECM components and transcription factors depended on cell type and pre-culturing condition. Zonal colonization of triphasic scaffolds using spheroids is possible, offering a novel approach for enthesis tissue engineering.
Collapse
Affiliation(s)
- Clemens Gögele
- Institute of Anatomy and Cell Biology, Paracelsus Medical University, Nuremberg and Salzburg, Prof. Ernst Nathan Str. 1, 90419 Nuremberg, Germany
| | - Julia Vogt
- Institute of Anatomy and Cell Biology, Paracelsus Medical University, Nuremberg and Salzburg, Prof. Ernst Nathan Str. 1, 90419 Nuremberg, Germany
| | - Judith Hahn
- Department Materials Engineering, Institute of Polymers Materials, Leibniz-Institut für Polymerforschung Dresden e.V. (IPF), Hohe Straße 6, 01069 Dresden, Germany
| | - Annette Breier
- Department Materials Engineering, Institute of Polymers Materials, Leibniz-Institut für Polymerforschung Dresden e.V. (IPF), Hohe Straße 6, 01069 Dresden, Germany
| | - Ricardo Bernhardt
- Department Materials Engineering, Institute of Polymers Materials, Leibniz-Institut für Polymerforschung Dresden e.V. (IPF), Hohe Straße 6, 01069 Dresden, Germany
| | - Michael Meyer
- FILK Freiberg Institute gGmbH (FILK), Meißner Ring 1-5, 09599 Freiberg, Germany
| | - Michaela Schröpfer
- FILK Freiberg Institute gGmbH (FILK), Meißner Ring 1-5, 09599 Freiberg, Germany
| | - Kerstin Schäfer-Eckart
- Bone Marrow Transplantation Unit, Medizinische Klinik 5, Klinikum Nürnberg, 90419 Nuremberg, Germany
| | - Gundula Schulze-Tanzil
- Institute of Anatomy and Cell Biology, Paracelsus Medical University, Nuremberg and Salzburg, Prof. Ernst Nathan Str. 1, 90419 Nuremberg, Germany
| |
Collapse
|
6
|
Tindell RK, Busselle LP, Holloway JL. Magnetic fields enable precise spatial control over electrospun fiber alignment for fabricating complex gradient materials. J Biomed Mater Res A 2023; 111:778-789. [PMID: 36594559 DOI: 10.1002/jbm.a.37492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2022] [Revised: 12/14/2022] [Accepted: 12/16/2022] [Indexed: 01/04/2023]
Abstract
Musculoskeletal interfacial tissues consist of complex gradients in structure, cell phenotype, and biochemical signaling that are important for function. Designing tissue engineering strategies to mimic these types of gradients is an ongoing challenge. In particular, new fabrication techniques that enable precise spatial control over fiber alignment are needed to better mimic the structural gradients present in interfacial tissues, such as the tendon-bone interface. Here, we report a modular approach to spatially controlling fiber alignment using magnetically-assisted electrospinning. Electrospun fibers were highly aligned in the presence of a magnetic field and smoothly transitioned to randomly aligned fibers away from the magnetic field. Importantly, magnetically-assisted electrospinning allows for spatial control over fiber alignment at sub-millimeter resolution along the length of the fibrous scaffold similar to the native structural gradient present in many interfacial tissues. The versatility of this approach was further demonstrated using multiple electrospinning polymers and different magnet configurations to fabricate complex fiber alignment gradients. As expected, cells seeded onto gradient fibrous scaffolds were elongated and aligned on the aligned fibers and did not show a preferential alignment on the randomly aligned fibers. Overall, this fabrication approach represents an important step forward in creating gradient fibrous materials, where such materials are promising as tissue-engineered scaffolds for regenerating functional musculoskeletal interfacial tissues.
Collapse
Affiliation(s)
- Raymond Kevin Tindell
- Chemical Engineering, School of Engineering of Matter, Transport and Energy, Arizona State University, Tempe, Arizona, USA
| | - Lincoln P Busselle
- Chemical Engineering, School of Engineering of Matter, Transport and Energy, Arizona State University, Tempe, Arizona, USA
| | - Julianne L Holloway
- Chemical Engineering, School of Engineering of Matter, Transport and Energy, Arizona State University, Tempe, Arizona, USA
| |
Collapse
|
7
|
Nyland J, Pyle B, Krupp R, Kittle G, Richards J, Brey J. ACL microtrauma: healing through nutrition, modified sports training, and increased recovery time. J Exp Orthop 2022; 9:121. [PMID: 36515744 PMCID: PMC9751252 DOI: 10.1186/s40634-022-00561-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Accepted: 12/05/2022] [Indexed: 12/15/2022] Open
Abstract
PURPOSE Sports injuries among youth and adolescent athletes are a growing concern, particularly at the knee. Based on our current understanding of microtrauma and anterior cruciate ligament (ACL) healing characteristics, this clinical commentary describes a comprehensive plan to better manage ACL microtrauma and mitigate the likelihood of progression to a non-contact macrotraumatic ACL rupture. METHODS Medical literature related to non-contact ACL injuries among youth and adolescent athletes, collagen and ACL extracellular matrix metabolism, ACL microtrauma and sudden failure, and concerns related to current sports training were reviewed and synthesized into a comprehensive intervention plan. RESULTS With consideration for biopsychosocial model health factors, proper nutrition and modified sports training with increased recovery time, a comprehensive primary ACL injury prevention plan is described for the purpose of better managing ACL microtrauma, thereby reducing the incidence of non-contact macrotraumatic ACL rupture among youth and adolescent athletes. CONCLUSION Preventing non-contact ACL injuries may require greater consideration for reducing accumulated ACL microtrauma. Proper nutrition including glycine-rich collagen peptides, or gelatin-vitamin C supplementation in combination with healthy sleep, and adjusted sports training periodization with increased recovery time may improve ACL extracellular matrix collagen deposition homeostasis, decreasing sudden non-contact ACL rupture incidence likelihood in youth and adolescent athletes. Successful implementation will require compliance from athletes, parents, coaches, the sports medicine healthcare team, and event organizers. Studies are needed to confirm the efficacy of these concepts. LEVEL OF EVIDENCE V.
Collapse
Affiliation(s)
- J Nyland
- Norton Orthopedic Institute, 9880 Angies Way, Louisville, KY, 40241, USA.
- MSAT Program, Spalding University, 901 South Third St, Louisville, KY, USA.
- Department of Orthopaedic Surgery, University of Louisville, Louisville, KY, USA.
| | - B Pyle
- MSAT Program, Spalding University, 901 South Third St, Louisville, KY, USA
| | - R Krupp
- Norton Orthopedic Institute, 9880 Angies Way, Louisville, KY, 40241, USA
- Department of Orthopaedic Surgery, University of Louisville, Louisville, KY, USA
| | - G Kittle
- MSAT Program, Spalding University, 901 South Third St, Louisville, KY, USA
| | - J Richards
- Department of Orthopaedic Surgery, University of Louisville, Louisville, KY, USA
| | - J Brey
- Norton Orthopedic Institute, 9880 Angies Way, Louisville, KY, 40241, USA
- Department of Orthopaedic Surgery, University of Louisville, Louisville, KY, USA
| |
Collapse
|
8
|
Shi Q, Wang H, He K, Tao M, Cheng CK. Comparison of the morphology of the anterior cruciate ligament and related bony structures between pigs and humans. Front Vet Sci 2022; 9:1045785. [PMID: 36467640 PMCID: PMC9716283 DOI: 10.3389/fvets.2022.1045785] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Accepted: 11/03/2022] [Indexed: 07/20/2023] Open
Abstract
INTRODUCTION Pigs are widely used for clinical research on the anterior cruciate ligament (ACL) because of the similarity of the knee structure to the human knee. But evidence to support the suitability of using porcine samples to guide clinical practices is limited. This study aims to explore the qualitative and quantitative morphological features of the porcine knee and ACL, and to compare these with data on humans reported in literature. METHODS Nineteen porcine knees were used for this study. The bone structures were measured on coronal X-ray images. The length of the ACL was measured using a caliper. The ACL bone insertion sites were marked and measured on a digital photograph. The lengths of the long and short axis of the ACL isthmus were measured on the X-ray microscopy reconstructed images. The outcomes were compared with previously reported data on humans using an abstract independent-samples T test. RESULTS Qualitative observation indicated a similar location, orientation and general morphology of the porcine ACL to human ACLs. The major difference was the location of the ACL tibial insertion with respect to the anterior horn of the lateral meniscus (AHLM). The porcine ACL was split into AM and PL bundles by the AHLM, while the AHLM was adjacent to the anterolateral border of the ACL tibial insertion in human knees. The quantitative comparison showed no significant difference between the human and porcine ACL in terms of the length of the ACL, the width of the femoral condyle and tibial plateau, and the tibial interspinal width. However, the CSA, the lengths of the long and short axis of the ACL isthmus, and the femoral and tibial insertion areas of the porcine ACL were all significantly larger than the reported features in human knees. CONCLUSION The location, orientation and basic morphology of the porcine ACL and knee are similar to humans. However, the two-bundle structure is more distinct in a porcine ACL, and the dimensions of the porcine ACL are generally larger. This study may provide useful information to researchers when assessing the feasibility and limitations of using porcine samples for research on the human ACL and knee.
Collapse
|
9
|
Hargrave‐Thomas EJ, Thambyah A. The micro and ultrastructural anatomy of bone spicules found in the osteochondral junction of bovine patellae with early joint degeneration. J Anat 2021; 239:1452-1464. [PMID: 34289114 PMCID: PMC8602024 DOI: 10.1111/joa.13518] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Revised: 07/02/2021] [Accepted: 07/06/2021] [Indexed: 01/08/2023] Open
Abstract
The structural changes in the tissues of the osteochondral junction are a topic of interest, especially considering how bone changes are involved in the initiation and progression of osteoarthritis (OA). Our research group has previously demonstrated that at the cement line boundary between the zone of calcified cartilage (ZCC) and the subchondral bone, in mature bovine patellae with early OA, there are numerous bone spicules that have emerged from the underlying bone. These spicules contain a central vascular canal and a bone cuff. In this study, we use high-resolution differential interference contrast optical microscopy and scanning electron microscopy to compare the cartilage-bone junction of three groups of mature bovine patellae showing healthy to mild to moderately degenerate cartilage. The ZCC and bone junction was carefully examined to estimate the frequency of marrow spaces, bone spicules and fully formed bone bulges. The results reveal that bone spicules are associated with all grades of cartilage tissue studied, with the most occurring in the intermediate stages of tissue health. The micro and ultrastructure of the bone spicule are consistent with that of an osteon, especially those found in compression zones in long bones. Also considering the coexistence of marrow spaces and fully formed bone, this study suggests that these bone spicules arise similar to the formation of osteons in the bone remodelling process. The significance of this conclusion is in the way researchers approach the bone formation issue in the early degenerative joint. Instead of endochondral ossification, we propose that bone formation in OA is more akin to a combination of primary bone remodelling and de novo bone formation.
Collapse
Affiliation(s)
- Emily J. Hargrave‐Thomas
- Experimental Tissue Mechanics LaboratoryDepartment of Chemical and Materials EngineeringUniversity of AucklandAucklandNew Zealand
| | - Ashvin Thambyah
- Experimental Tissue Mechanics LaboratoryDepartment of Chemical and Materials EngineeringUniversity of AucklandAucklandNew Zealand
| |
Collapse
|
10
|
Pitta Kruize C, Panahkhahi S, Putra NE, Diaz-Payno P, van Osch G, Zadpoor AA, Mirzaali MJ. Biomimetic Approaches for the Design and Fabrication of Bone-to-Soft Tissue Interfaces. ACS Biomater Sci Eng 2021. [PMID: 34784181 DOI: 10.1021/acsbiomaterials.1c00620] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Bone-to-soft tissue interfaces are responsible for transferring loads between tissues with significantly dissimilar material properties. The examples of connective soft tissues are ligaments, tendons, and cartilages. Such natural tissue interfaces have unique microstructural properties and characteristics which avoid the abrupt transitions between two tissues and prevent formation of stress concentration at their connections. Here, we review some of the important characteristics of these natural interfaces. The native bone-to-soft tissue interfaces consist of several hierarchical levels which are formed in a highly specialized anisotropic fashion and are composed of different types of heterogeneously distributed cells. The characteristics of a natural interface can rely on two main design principles, namely by changing the local microarchitectural features (e.g., complex cell arrangements, and introducing interlocking mechanisms at the interfaces through various geometrical designs) and changing the local chemical compositions (e.g., a smooth and gradual transition in the level of mineralization). Implementing such design principles appears to be a promising approach that can be used in the design, reconstruction, and regeneration of engineered biomimetic tissue interfaces. Furthermore, prominent fabrication techniques such as additive manufacturing (AM) including 3D printing and electrospinning can be used to ease these implementation processes. Biomimetic interfaces have several biological applications, for example, to create synthetic scaffolds for osteochondral tissue repair.
Collapse
Affiliation(s)
- Carlos Pitta Kruize
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft, The Netherlands
| | - Sara Panahkhahi
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft, The Netherlands
| | - Niko Eka Putra
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft, The Netherlands
| | - Pedro Diaz-Payno
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft, The Netherlands
| | - Gerjo van Osch
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft, The Netherlands
| | - Amir A Zadpoor
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft, The Netherlands
| | - Mohammad J Mirzaali
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft, The Netherlands
| |
Collapse
|
11
|
Yamauchi S, Ishibashi K, Sasaki E, Sasaki S, Kimura Y, Ishibashi Y. Failure load of the femoral insertion site of the anterior cruciate ligament in a porcine model: comparison of different portions and knee flexion angles. J Orthop Surg Res 2021; 16:526. [PMID: 34429129 PMCID: PMC8383361 DOI: 10.1186/s13018-021-02676-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 08/15/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND This study compared the failure load of the femoral insertion site of the anterior cruciate ligament between different portions and knee flexion angles. METHODS In total, 87 fresh-frozen, porcine knees were used in this study. Three knees were used for histological evaluation; the remaining 84 knees were randomly divided into 4 groups: anterior anteromedial bundle, posterior anteromedial bundle, anterior posterolateral bundle, and posterior posterolateral bundle groups (n=21 per group). The anterior cruciate ligament femoral insertion site was divided into these four areas and excised, leaving a 3-mm square attachment in the center of each bundle. Tibia-anterior cruciate ligament-femur complexes were placed in a material testing machine at 30°, 120°, and 150° of knee flexion (n=7), and the failure load for each portion was measured under anterior tibial loading (0.33 mm/s). RESULTS Histological study showed that the anterior cruciate ligament femoral insertion site consisted of direct and indirect insertions. Comparison of the failure load between the knee flexion angles revealed that all the failure loads decreased with knee flexion; significant decreases were observed in the failure load between 30 and 150° knee flexion in the posterior anteromedial bundle and posterior posterolateral bundle groups. Comparison of the failure load according to different portions revealed a significant difference between the anteromedial and posterolateral bundle groups at 150° of knee flexion, but no significant difference among the groups at 30° of flexion. CONCLUSIONS Although the failure load of the posterior portion decreased significantly in the knee flexion position, it (mainly consisting of indirect insertion) plays a significant role against anterior tibial load in the knee extension position; this appears to be related to the characteristics of the insertion site. Reflecting the complex structure and function of the ACL, this study showed that the failure load of the femoral insertion site varies with differences in positions and knee flexion angles.
Collapse
Affiliation(s)
- Shohei Yamauchi
- Department of Orthopaedic Surgery, Hirosaki University Graduate School of Medicine, 5 Zaifu-cho, Hirosaki, Aomori, 036-8562 Japan
| | | | - Eiji Sasaki
- Department of Orthopaedic Surgery, Hirosaki University Graduate School of Medicine, 5 Zaifu-cho, Hirosaki, Aomori, 036-8562 Japan
| | - Shizuka Sasaki
- Department of Orthopaedic Surgery, Hirosaki University Graduate School of Medicine, 5 Zaifu-cho, Hirosaki, Aomori, 036-8562 Japan
| | - Yuka Kimura
- Department of Orthopaedic Surgery, Hirosaki University Graduate School of Medicine, 5 Zaifu-cho, Hirosaki, Aomori, 036-8562 Japan
| | - Yasuyuki Ishibashi
- Department of Orthopaedic Surgery, Hirosaki University Graduate School of Medicine, 5 Zaifu-cho, Hirosaki, Aomori, 036-8562 Japan
| |
Collapse
|
12
|
Tits A, Plougonven E, Blouin S, Hartmann MA, Kaux JF, Drion P, Fernandez J, van Lenthe GH, Ruffoni D. Local anisotropy in mineralized fibrocartilage and subchondral bone beneath the tendon-bone interface. Sci Rep 2021; 11:16534. [PMID: 34400706 PMCID: PMC8367976 DOI: 10.1038/s41598-021-95917-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Accepted: 08/02/2021] [Indexed: 12/19/2022] Open
Abstract
The enthesis allows the insertion of tendon into bone thanks to several remarkable strategies. This complex and clinically relevant location often features a thin layer of fibrocartilage sandwiched between tendon and bone to cope with a highly heterogeneous mechanical environment. The main purpose of this study was to investigate whether mineralized fibrocartilage and bone close to the enthesis show distinctive three-dimensional microstructural features, possibly to enable load transfer from tendon to bone. As a model, the Achilles tendon-calcaneus bone system of adult rats was investigated with histology, backscattered electron imaging and micro-computed tomography. The microstructural porosity of bone and mineralized fibrocartilage in different locations including enthesis fibrocartilage, periosteal fibrocartilage and bone away from the enthesis was characterized. We showed that calcaneus bone presents a dedicated protrusion of low porosity where the tendon inserts. A spatially resolved analysis of the trabecular network suggests that such protrusion may promote force flow from the tendon to the plantar ligament, while partially relieving the trabecular bone from such a task. Focusing on the tuberosity, highly specific microstructural aspects were highlighted. Firstly, the interface between mineralized and unmineralized fibrocartilage showed the highest roughness at the tuberosity, possibly to increase failure resistance of a region carrying large stresses. Secondly, fibrochondrocyte lacunae inside mineralized fibrocartilage, in analogy with osteocyte lacunae in bone, had a predominant alignment at the enthesis and a rather random organization away from it. Finally, the network of subchondral channels inside the tuberosity was highly anisotropic when compared to contiguous regions. This dual anisotropy of subchondral channels and cell lacunae at the insertion may reflect the alignment of the underlying collagen network. Our findings suggest that the microstructure of fibrocartilage may be linked with the loading environment. Future studies should characterize those microstructural aspects in aged and or diseased conditions to elucidate the poorly understood role of bone and fibrocartilage in enthesis-related pathologies.
Collapse
Affiliation(s)
- Alexandra Tits
- Mechanics of Biological and Bioinspired Materials Laboratory, Department of Aerospace and Mechanical Engineering, University of Liège, Quartier Polytech 1, Allée de la Découverte 9, 4000, Liège, Belgium
| | - Erwan Plougonven
- Chemical Engineering Department, University of Liège, Liège, Belgium
| | - Stéphane Blouin
- Ludwig Boltzmann Institute of Osteology, Hanusch Hospital of OEGK and AUVA Trauma Centre Meidling, 1st Medical Department Hanusch Hospital, Vienna, Austria
| | - Markus A Hartmann
- Ludwig Boltzmann Institute of Osteology, Hanusch Hospital of OEGK and AUVA Trauma Centre Meidling, 1st Medical Department Hanusch Hospital, Vienna, Austria
| | - Jean-François Kaux
- Department of Physical Medicine and Sports Traumatology, University of Liège and University Hospital of Liège, Liège, Belgium
| | - Pierre Drion
- Experimental Surgery Unit, GIGA and Credec, University of Liege, Liege, Belgium
| | - Justin Fernandez
- Auckland Bioengineering Institute and Department of Engineering Science, University of Auckland, Auckland, New Zealand
| | | | - Davide Ruffoni
- Mechanics of Biological and Bioinspired Materials Laboratory, Department of Aerospace and Mechanical Engineering, University of Liège, Quartier Polytech 1, Allée de la Découverte 9, 4000, Liège, Belgium.
| |
Collapse
|
13
|
Tracking tendon fibers to their insertion - a 3D analysis of the Achilles tendon enthesis in mice. Acta Biomater 2021; 120:146-155. [PMID: 32428686 DOI: 10.1016/j.actbio.2020.05.001] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Revised: 04/16/2020] [Accepted: 05/01/2020] [Indexed: 11/23/2022]
Abstract
Tendon insertions to bone are heavily loaded transitions between soft and hard tissues. The fiber courses in the tendon have profound effects on the distribution of stress along and across the insertion. We tracked fibers of the Achilles tendon in mice in micro-computed tomographies and extracted virtual transversal sections. The fiber tracks and shapes were analyzed from a position in the free tendon to the insertion. Mechanically relevant parameters were extracted. The fiber number was found to stay about constant along the tendon. But the fiber cross-sectional areas decrease towards the insertion. The fibers mainly interact due to tendon twist, while branching only creates small branching clusters with low levels of divergence along the tendon. The highest fiber curvatures were found within the unmineralized entheseal fibrocartilage. The fibers inserting at a protrusion of the insertion area form a distinct portion within the tendon. Tendon twist is expected to contribute to a homogeneous distribution of stress among the fibers. According to the low cross-sectional areas and the high fiber curvatures, tensile and compressive stress are expected to peak at the insertion. These findings raise the question whether the insertion is reinforced in terms of fiber strength or by other load-bearing components besides the fibers. STATEMENT OF SIGNIFICANCE: The presented study is the first analysis of the 3D fiber tracks in macroscopic tendon samples as determined by a combination of cell-maceration, phase-contrast µCT and template-based tracking. The structural findings change the understanding of the tendon-bone insertion and its biomechanics: (1) The insertion is not reinforced in terms of fiber numbers or sizes. Its robustness remains unexplained. (2) The orientation of fibers in the tendon center is higher than in the margins. This arrangement could inspire material development. (3) Fibers inserting at a protrusion of the insertion area stem from a distinct portion within the tendon. The results show that fibrous structure analysis can link macro- to micromechanics and that it is ready for the application to complete muscle-tendon units.
Collapse
|
14
|
Wang Z, Xiong Y, Chen G, Tang X, Li Q, Zhang Z, Shang X, Yang Y, Sulaiman Y, Li J. Modified tibial tunnel placement for single-bundle posterior cruciate ligament reconstruction reduces the "Killer Turn" in a biomechanical model. Medicine (Baltimore) 2019; 98:e18439. [PMID: 31876724 PMCID: PMC6946428 DOI: 10.1097/md.0000000000018439] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND Our previous three-dimensional finite element analysis found that posterior cruciate ligament (PCL) reconstruction in the modified tibial tunneling placement (MTT, 10 mm inferior and 5 mm lateral to the PCL anatomical insertion) could reduce the peak stress of the graft and may reduce the killer turn. The purpose of the current study was to compare the biomechanical results between MTT and traditional tibial tunneling technique (TTT, PCL anatomical insertion) during transtibial PCL reconstruction. METHODS Fifty-six 3D-printed tibia models and fresh mature porcine flexor digitorum tendons were studied. The PCL reconstruction specimens were randomly divided into TTT group and MTT group based on tibial tunnel placement. A 50 to 300 N cyclic loading was applied using a material testing system. Each specimen completed 2000 cycles at a rate of 200 mm/min and a loading frequency of 80 cycles/min. Load-displacement curves, failure mode, and graft displacement were recorded. Mean maximum contact pressure was measured using a pressure-sensitive film. After cyclic loading test, the surviving grafts were randomly assigned to load-to-failure group or Scanning Electron Microscopy (SEM) group. Ultimate failure load and the appearance of graft abrasion were recorded and analyzed. RESULT During the cyclic loading test, 3 samples in the TTT group, and 2 in the MTT group were excluded because of the graft pullout during the test. Mean maximum contact pressure of killer turn was 9.30 ± 0.29 MPa in the TTT group and 7.27 ± 0.25 MPa in MTT group (P < .05). Mean graft displacement was 4.54 ± 0.23 mm in the TTT group and 3.37 ± 3.56 mm in the MTT group (P < .05). Maximum failure load was 1886.0 ± 41.83 N in the TTT group and 2019.30 ± 20.10 N in the MTT group (P < .05). The SEM analysis showed heavy abrasion and fiber discontinuity in graft in the TTT group, while it showed slight abrasion and fiber arrangement disorders in the MTT group. CONCLUSIONS The MTT PCL reconstruction significantly reduced stress concentration and graft abrasion as compared with the TTT PCL reconstruction, and it may be a better choice for the reduction of "killer Turn" effect during transtibial PCL construction.
Collapse
Affiliation(s)
- Zhiqiang Wang
- Department of Orthopaedic Surgery, West China Hospital, Sichuan University
- Department of Orthopaedic Surgery, Suining Central Hospital, Sichuan, China
| | - Yan Xiong
- Department of Orthopaedic Surgery, West China Hospital, Sichuan University
| | - Gang Chen
- Department of Orthopaedic Surgery, West China Hospital, Sichuan University
| | - Xin Tang
- Department of Orthopaedic Surgery, West China Hospital, Sichuan University
| | - Qi Li
- Department of Orthopaedic Surgery, West China Hospital, Sichuan University
| | - Zhong Zhang
- Department of Orthopaedic Surgery, West China Hospital, Sichuan University
| | - Xiaoke Shang
- Department of Orthopaedic Surgery, West China Hospital, Sichuan University
| | - Yuan Yang
- Department of Orthopaedic Surgery, West China Hospital, Sichuan University
| | - Yaxiaer Sulaiman
- Department of Orthopaedic Surgery, West China Hospital, Sichuan University
| | - Jian Li
- Department of Orthopaedic Surgery, West China Hospital, Sichuan University
| |
Collapse
|
15
|
Chai F, Wan F, Jiang J, Chen S. Micro-scale assessment of the postoperative effect of anterior cruciate ligament reconstruction preclinical study using a 7.1T micro-magnetic resonance imaging. Exp Ther Med 2019; 17:214-220. [PMID: 30651785 PMCID: PMC6307410 DOI: 10.3892/etm.2018.6080] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2017] [Accepted: 03/01/2018] [Indexed: 11/26/2022] Open
Abstract
High-field micro-magnetic resonance imaging (MRI) scanning may provide additional information for quantitative analysis of graft bone healing processes, thus serving as a promising supplementary method in graft and bone healing evaluation following anterior cruciate ligament reconstruction (ACLR) surgery during preclinical studies. The present study included 12 New Zealand white rabbits that underwent ACLR with polyethylene terephthalate (PET) ligament. At 4, 8, and 16 weeks following surgery, 4 rabbits were euthanized and knee joint samples were harvested for a 7.1T micro-magnetic resonance imaging (MRI) scan. The graft bone tunnel diameter and signal noise ratio (SNR) at the region of interest (ROI) were measured. Hematoxylin-eosin staining was performed at each time point to verify the graft bone healing process in histology. The bone tunnel diameter at the graft tunnel interface decreased over time in both femoral and tibial parts. Notably, the tunnel size was smaller than the diameter of the drilling Kirschner wire that was used to observe the femoral part and proximal site of the tibial part at 16 weeks following surgery. SNR research demonstrated that both the femoral and tibial part PET ligaments selected in the ROI exhibited a marked increase in SNR from the initial 4-week results. The micro-MRI result was consistent with that of histological analysis. Micro-MRI scanning was applied in an animal model that underwent ACL reconstruction surgery with PET ligament, and it was determined that micro-MRI is promising in quantitatively observing graft bone healing processes directly with a focus on graft tunnel distances and SNRs.
Collapse
Affiliation(s)
- Fang Chai
- Department of Orthopedics, Zhejiang Provincial People's Hospital, People's Hospital of Hangzhou Medical College, Hangzhou, Zhejiang 310003, P.R. China.,Department of Sports Medicine and Arthroscopic Surgery, Huashan Hospital, Sports Medicine Center, Fudan University, Shanghai 200040, P.R. China
| | - Fang Wan
- Department of Sports Medicine and Arthroscopic Surgery, Huashan Hospital, Sports Medicine Center, Fudan University, Shanghai 200040, P.R. China
| | - Jia Jiang
- Department of Sports Medicine and Arthroscopic Surgery, Huashan Hospital, Sports Medicine Center, Fudan University, Shanghai 200040, P.R. China
| | - Shiyi Chen
- Department of Sports Medicine and Arthroscopic Surgery, Huashan Hospital, Sports Medicine Center, Fudan University, Shanghai 200040, P.R. China
| |
Collapse
|
16
|
Sevick JL, Abusara Z, Andrews SH, Xu M, Khurshid S, Chatha J, Hart DA, Shrive NG. Fibril deformation under load of the rabbit Achilles tendon and medial collateral ligament femoral entheses. J Orthop Res 2018; 36:2506-2515. [PMID: 29637610 DOI: 10.1002/jor.23912] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2017] [Accepted: 03/30/2018] [Indexed: 02/04/2023]
Abstract
Microscopic visualization under load of the region connecting ligaments/tendons to bone, the enthesis, has been performed previously; however, specific investigation of individual fibril deformation may add insight to such studies. Detailed visualization of fibril deformation would inform on the mechanical strategies employed by this tissue in connecting two mechanically disparate materials. Clinically, an improved understanding of enthesis mechanics may help guide future restorative efforts for torn or injured ligaments/tendons, where the enthesis is often a point of weakness. In this study, a custom ligament/tendon enthesis loading device was designed and built, a unique method of sample preparation was devised, and second harmonic and two-photon fluorescence microscopy were used to capture the fibril-level load response of the rabbit Achilles tendon and medial collateral ligament femoral entheses. A focus was given to investigation of the mechanical problem of fibril embedment. Resultant images indicate a rapid (occurring over approximately 60 μm) change in fibril orientation at the interface of ligament/tendon and calcified fibrocartilage early in the loading regime, before becoming relatively constant. Such a change in fibril angle helps confirm the materially graded region demonstrated by others, while, in this case, providing additional insight into fibril bending. We speculate that the scale of the mechanical problem (i.e., fibril diameters being on the order of 250 nm) allows fibrils to bend over the small (relative to the imaging field of view, but large relative to fibril diameter) distances observed; thus, potentially lessening required embedment lengths. Nevertheless, this behavior merits further investigation to be confirmed. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:2506-2515, 2018.
Collapse
Affiliation(s)
- Johnathan L Sevick
- McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, Alberta, Canada.,Biomedical Engineering Graduate Program, University of Calgary, Calgary, Alberta, Canada
| | - Ziad Abusara
- McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, Alberta, Canada.,Faculty of Kinesiology, Human Performance Laboratory, University of Calgary, Calgary, Alberta, Canada
| | - Stephen H Andrews
- McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, Alberta, Canada
| | - Minjia Xu
- McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, Alberta, Canada
| | - Saad Khurshid
- McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, Alberta, Canada.,Department of Civil Engineering, Schulich School of Engineering, University of Calgary, Calgary, Alberta, Canada
| | - Jansher Chatha
- McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, Alberta, Canada.,Department of Civil Engineering, Schulich School of Engineering, University of Calgary, Calgary, Alberta, Canada
| | - David A Hart
- McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, Alberta, Canada
| | - Nigel G Shrive
- McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, Alberta, Canada.,Department of Civil Engineering, Schulich School of Engineering, University of Calgary, Calgary, Alberta, Canada
| |
Collapse
|
17
|
Qu D, Subramony SD, Boskey AL, Pleshko N, Doty SB, Lu HH. Compositional mapping of the mature anterior cruciate ligament-to-bone insertion. J Orthop Res 2017; 35:2513-2523. [PMID: 28176356 PMCID: PMC5548644 DOI: 10.1002/jor.23539] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2016] [Accepted: 01/27/2017] [Indexed: 02/04/2023]
Abstract
The anterior cruciate ligament (ACL)-to-bone interface constitutes a complex, multi-tissue structure comprised of contiguous ligament, non-mineralized fibrocartilage, mineralized fibrocartilage, and bone regions. This composite structure enables load transfer between structurally and functionally dissimilar tissues and is critical for ligament homeostasis and joint stability. Presently, there is a lack of quantitative understanding of the matrix composition and organization across this junction, especially after the onset of skeletal maturity. The objective of this study is to characterize the adult bovine ACL-to-bone interface using Fourier transform infrared spectroscopic imaging (FTIRI), testing the hypothesis that regional changes in collagen, proteoglycan, and mineral distribution, as well as matrix organization, persist at the mature insertion. It was observed that while collagen content increases continuously across the adult interface, collagen alignment decreases between ligament and bone. Proteoglycans were primarily localized to the fibrocartilage region and an exponential increase in mineral content was observed between the non-mineralized and mineralized regions. These observations reveal significant changes in collagen distribution and alignment with maturity, and these trends underscore the role of physiologic loading in postnatal matrix remodeling. Findings from this study provide new insights into interface organization and serve as benchmark design criteria for interface regeneration and integrative soft tissue repair. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2513-2523, 2017.
Collapse
Affiliation(s)
- Dovina Qu
- Biomaterials and Interface Tissue Engineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY 10027
| | - Siddarth D. Subramony
- Biomaterials and Interface Tissue Engineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY 10027
| | - Adele L. Boskey
- Musculoskeletal Integrity Program, Hospital for Special Surgery, New York, NY 10021
| | - Nancy Pleshko
- Tissue Imaging and Spectroscopy Laboratory, Department of Bioengineering, Temple University, Philadelphia, PA 19122
| | - Stephen B. Doty
- Analytical Microscopy Laboratory, Hospital for Special Surgery, New York, NY 10021
| | - Helen H. Lu
- Biomaterials and Interface Tissue Engineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY 10027,To whom all correspondence should be addressed: Helen H. Lu, Ph.D., Department of Biomedical Engineering, Columbia University1210 Amsterdam Avenue, 351 Engineering Terrace, MC 8904, New York, NY 10027, 212-854-4071 (office), 212-854-8725 (fax),
| |
Collapse
|
18
|
Zhao L, Lee PV, Ackland DC, Broom ND, Thambyah A. Microstructure Variations in the Soft-Hard Tissue Junction of the Human Anterior Cruciate Ligament. Anat Rec (Hoboken) 2017; 300:1547-1559. [DOI: 10.1002/ar.23608] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2016] [Revised: 03/21/2017] [Accepted: 04/06/2017] [Indexed: 01/18/2023]
Affiliation(s)
- Lei Zhao
- Experimental Tissue Mechanics Laboratory; Department of Chemical and Materials Engineering, University of Auckland; Auckland New Zealand
| | - Peter V.S. Lee
- Department of Biomedical Engineering; University of Melbourne; Victoria Australia
| | - David C. Ackland
- Department of Biomedical Engineering; University of Melbourne; Victoria Australia
| | - Neil D. Broom
- Experimental Tissue Mechanics Laboratory; Department of Chemical and Materials Engineering, University of Auckland; Auckland New Zealand
| | - Ashvin Thambyah
- Experimental Tissue Mechanics Laboratory; Department of Chemical and Materials Engineering, University of Auckland; Auckland New Zealand
| |
Collapse
|
19
|
Nyland J, Gamble C, Franklin T, Caborn DNM. Permanent knee sensorimotor system changes following ACL injury and surgery. Knee Surg Sports Traumatol Arthrosc 2017; 25:1461-1474. [PMID: 28154888 DOI: 10.1007/s00167-017-4432-y] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2016] [Accepted: 01/12/2017] [Indexed: 01/14/2023]
Abstract
The cruciate ligaments are components of the knee capsuloligamentous system providing vital neurosensory and biomechanical function. Since most historical primary ACL repair attempts were unsuccessful, reconstruction has become the preferred surgery. However, an increased understanding of the efficacy of lesion-site scaffolding, innovative suturing methods and materials, and evolving use of biological healing mediators such as platelet-rich plasma and stem cells has prompted reconsideration of what was once believed to be impossible. A growing number of in vivo animal studies and prospective clinical studies are providing increasing support for this intervention. The significance of ACL repair rather than reconstruction is that it more likely preserves the native neurosensory system, entheses, and ACL footprints. Tissue preservation combined with restored biomechanical function increases the likelihood for premorbid neuromuscular control system and dynamic knee stability recovery. This recovery should increase the potential for more patients to safely return to sports at their desired intensity and frequency. This current concepts paper revisits cruciate ligament neurosensory and neurovascular anatomy from the perspective of knee capsuloligamentous system function. Peripheral and central nerve pathways and central cortical representation mapping are also discussed. Surgical restoration of a more physiologically sound knee joint may be essential to solving the osteoarthritis dilemma. Innovative rehabilitative strategies and outcome measurement methodologies using more holistic and clinically relevant measurements that closely link biomechanical and neurosensory characteristics of physiological ACL function are discussed. Greater consideration of task-specific patient physical function and psychobehavioral links should better delineate the true efficacy of all ACL surgical and non-surgical interventions. Level of evidence IV.
Collapse
Affiliation(s)
- John Nyland
- Athletic Training Program Director and Professor, Kosair Charities College of Health and Natural Sciences, Spalding University, 901 South 4th Street, Louisville, KY, 40203, USA.
| | - Collin Gamble
- School of Medicine, University of Louisville, 323 East Chestnut Street, Louisville, KY, 40202, USA
| | - Tiffany Franklin
- Athletic Training Program Director and Professor, Kosair Charities College of Health and Natural Sciences, Spalding University, 901 South 4th Street, Louisville, KY, 40203, USA
| | - David N M Caborn
- Shea Orthopedic Group, KentuckyOne Health, 201 Abraham Flexner Way, Ste. 100, Louisville, KY, 40202, USA
| |
Collapse
|
20
|
Steineman BD, Moulton SG, Haut Donahue TL, Fontboté CA, LaPrade CM, Cram TR, Dean CS, LaPrade RF. Overlap Between Anterior Cruciate Ligament and Anterolateral Meniscal Root Insertions: A Scanning Electron Microscopy Study. Am J Sports Med 2017; 45:362-368. [PMID: 27729320 DOI: 10.1177/0363546516666817] [Citation(s) in RCA: 46] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND The anterolateral meniscal root (ALMR) has been reported to intricately insert underneath the tibial insertion of the anterior cruciate ligament (ACL). Previous studies have begun to evaluate the relationship between the insertion areas and the risk of iatrogenic injuries; however, the overlap of the insertions has yet to be quantified in the sagittal and coronal planes. PURPOSE To investigate the insertions of the human tibial ACL and ALMR using scanning electron microscopy (SEM) and to quantify the overlap of the ALMR insertion in the coronal and sagittal planes. STUDY DESIGN Descriptive laboratory study. METHODS Ten cadaveric knees were dissected to isolate the tibial ACL and ALMR insertions. Specimens were prepared and imaged in the coronal and sagittal planes. After imaging, fiber directions were examined to identify the insertions and used to calculate the percentage of the ACL that overlaps with the ALMR instead of inserting into bone. RESULTS Four-phase insertion fibers of the tibial ACL were identified directly medial to the ALMR insertion as they attached onto the tibial plateau. The mean percentage of ACL fibers overlapping the ALMR insertion instead of inserting into subchondral bone in the coronal and sagittal planes was 41.0% ± 8.9% and 53.9% ± 4.3%, respectively. The percentage of insertion overlap in the sagittal plane was significantly higher than in the coronal plane ( P = .02). CONCLUSION This study is the first to quantify the ACL insertion overlap of the ALMR insertion in the coronal and sagittal planes, which supplements previous literature on the insertion area overlap and iatrogenic injuries of the ALMR insertion. Future studies should determine how much damage to the ALMR insertion is acceptable to properly restore ACL function without increasing the risk for tears of the ALMR. CLINICAL RELEVANCE Overlap of the insertion areas on the tibial plateau has been previously reported; however, the results of this study demonstrate significant overlap of the insertions superior to the insertion sites on the tibial plateau as well. These findings need to be considered when positioning for tibial tunnel creation in ACL reconstruction to avoid damage to the ALMR insertion.
Collapse
Affiliation(s)
- Brett D Steineman
- School of Biomedical Engineering, Colorado State University, Fort Collins, Colorado, USA
| | | | - Tammy L Haut Donahue
- School of Biomedical Engineering, Colorado State University, Fort Collins, Colorado, USA.,Department of Mechanical Engineering, Colorado State University, Fort Collins, Colorado, USA
| | - Cristián A Fontboté
- Department of Orthopaedic Surgery, Pontificia Universidad Católica de Chile, Santiago, Chile
| | | | | | - Chase S Dean
- Steadman Philippon Research Institute, Vail, Colorado, USA
| | - Robert F LaPrade
- Steadman Philippon Research Institute, Vail, Colorado, USA.,The Steadman Clinic, Vail, Colorado, USA
| |
Collapse
|
21
|
Lin Z, Zhao X, Chen S, Du C. Osteogenic and tenogenic induction of hBMSCs by an integrated nanofibrous scaffold with chemical and structural mimicry of the bone–ligament connection. J Mater Chem B 2017; 5:1015-1027. [DOI: 10.1039/c6tb02156e] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
A novel electrospinning nanofiber collecting device was designed and utilized to fabricate an integrated PCL nanofibrous scaffold with a “random–aligned–random” structure.
Collapse
Affiliation(s)
- Zifeng Lin
- Department of Biomedical Engineering
- School of Materials Science and Engineering
- South China University of Technology
- Guangzhou 510641
- P. R. China
| | - Xiujuan Zhao
- Department of Biomedical Engineering
- School of Materials Science and Engineering
- South China University of Technology
- Guangzhou 510641
- P. R. China
| | - Si Chen
- Department of Biomedical Engineering
- School of Materials Science and Engineering
- South China University of Technology
- Guangzhou 510641
- P. R. China
| | - Chang Du
- Department of Biomedical Engineering
- School of Materials Science and Engineering
- South China University of Technology
- Guangzhou 510641
- P. R. China
| |
Collapse
|
22
|
Direct versus indirect ACL femoral attachment fibres and their implications on ACL graft placement. Knee Surg Sports Traumatol Arthrosc 2017; 25:165-171. [PMID: 27295056 DOI: 10.1007/s00167-016-4188-9] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2016] [Accepted: 05/31/2016] [Indexed: 01/16/2023]
Abstract
PURPOSE To further elucidate the direct and indirect fibre insertion morphology within the human ACL femoral attachment using scanning electron microscopy and determine where in the footprint each fibre type predominates. The hypothesis was that direct fibre attachment would be found centrally in the insertion site, while indirect fibre attachment would be found posteriorly adjacent to the posterior articular cartilage. METHODS Ten cadaveric knees were dissected to preserve and isolate the entirety of the femoral insertion of the ACL. Specimens were then prepared and evaluated with scanning electron microscopy to determine insertional fibre morphology and location. RESULTS The entirety of the fan-like projection of the ACL attachment site lay posterior to the lateral intercondylar ridge. In all specimens, a four-phase architecture, consistent with previous descriptions of direct fibres, was found in the centre of the femoral attachment site. The posterior margin of the ACL attachment attached directly adjacent to the posterior articular cartilage with some fibres coursing into it. The posterior portion of the ACL insertion had a two-phase insertion, consistent with previous descriptions of indirect fibres. The transition from the ligament fibres to bone had less interdigitations, and the interdigitations were significantly smaller (p < 0.001) compared to the transition in the direct fibre area. The interdigitations of the direct fibres were 387 ± 81 μm (range 282-515 μm) wide, while the interdigitations of indirect fibres measured 228 ± 75 μm (range 89-331 μm). CONCLUSIONS The centre of the ACL femoral attachment consisted of a direct fibre structure, while the posterior portion had an indirect fibre structure. These results support previous animal studies reporting that the centre of the ACL femoral insertion was comprised of the strongest reported fibre type. Clinically, the femoral ACL reconstruction tunnel should be oriented to cover the entirety of the central direct ACL fibres and may need to be customized based on graft type and the fixation device used during surgery.
Collapse
|
23
|
Qu D, Chuang PJ, Prateepchinda S, Balasubramanian PS, Yao X, Doty SB, Hendon CP, Lu HH. Micro- and Ultrastructural Characterization of Age-Related Changes at the Anterior Cruciate Ligament-to-Bone Insertion. ACS Biomater Sci Eng 2016; 3:2806-2814. [PMID: 33418704 DOI: 10.1021/acsbiomaterials.6b00602] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
There remains a lack of understanding of the structural changes that occur across the complex, multitissue anterior cruciate ligament (ACL)-to-bone insertion as a function of aging. The objective of this study is to provide a multiscale comparison of matrix properties across the skeletally immature and mature ACL-to-bone insertion. Using complementary imaging methods, micro- and ultrastructural analysis of the insertion revealed that collagen fiber orientation at the interface changes with age, though the degree of collagen organization is maintained over time. These changes are accompanied by a decrease in collagen fibril density and are likely driven by physiological loading. Mineral crystal structure and crystallinity are conserved over time, despite regional differences in crystallinity between the interface and bone. This suggests that mineral chemistry is established early in development and underscores its important functional role. Collectively, these findings provide new insights into interface development and set critical design benchmarks for integrative soft tissue repair.
Collapse
Affiliation(s)
- Dovina Qu
- Biomaterials and Interface Tissue Engineering Laboratory, Department of Biomedical Engineering, Columbia University, 1210 Amsterdam Avenue, 351 Engineering Terrace, MC 8904, New York, New York 10027, United States
| | - Philip J Chuang
- Biomaterials and Interface Tissue Engineering Laboratory, Department of Biomedical Engineering, Columbia University, 1210 Amsterdam Avenue, 351 Engineering Terrace, MC 8904, New York, New York 10027, United States
| | - Sagaw Prateepchinda
- Biomaterials and Interface Tissue Engineering Laboratory, Department of Biomedical Engineering, Columbia University, 1210 Amsterdam Avenue, 351 Engineering Terrace, MC 8904, New York, New York 10027, United States
| | - Priya S Balasubramanian
- Structure-Function Imaging Laboratory, Department of Electrical Engineering, Columbia University, 500 W. 120th Street, 1300 S. W. Mudd Building, MC 4712, New York, New York 10027, United States
| | - Xinwen Yao
- Structure-Function Imaging Laboratory, Department of Electrical Engineering, Columbia University, 500 W. 120th Street, 1300 S. W. Mudd Building, MC 4712, New York, New York 10027, United States
| | - Stephen B Doty
- Analytical Microscopy Laboratory, Hospital for Special Surgery, 535 East 70th Street, New York, New York 10021, United States
| | - Christine P Hendon
- Structure-Function Imaging Laboratory, Department of Electrical Engineering, Columbia University, 500 W. 120th Street, 1300 S. W. Mudd Building, MC 4712, New York, New York 10027, United States
| | - Helen H Lu
- Biomaterials and Interface Tissue Engineering Laboratory, Department of Biomedical Engineering, Columbia University, 1210 Amsterdam Avenue, 351 Engineering Terrace, MC 8904, New York, New York 10027, United States
| |
Collapse
|
24
|
Locke RC, Abraham AC, Killian ML. Orthopedic Interface Repair Strategies Based on Native Structural and Mechanical Features of the Multiscale Enthesis. ACS Biomater Sci Eng 2016; 3:2633-2643. [PMID: 32832593 DOI: 10.1021/acsbiomaterials.6b00599] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The enthesis is an organ that connects a soft, aligned tissue (tendon/ligament) to a hard, amorphous tissue (bone) via a fibrocartilage interface. Mechanically, the enthesis sustains a dynamic loading environment that includes tensile, compressive, and shear forces. The structural components of the enthesis act to minimize stress concentrations and control stretch at the interface. Current surgical repair of the enthesis, such as in rotator cuff repair and anterior cruciate ligament reconstruction, aim to bridge the gap between the injured ends via reattachment of soft-to-hard tissues or graft replacement. In this review, we discuss the multiscale, morphological, and mechanical characteristics of the fibrocartilage attachment. Additionally, we review historical and recent clinical approaches to treating enthesis injury. Lastly, we explore new technological advancements in tissue-engineered biomaterials that have shown promise in preclinical studies.
Collapse
Affiliation(s)
- Ryan C Locke
- Department of Biomedical Engineering, University of Delaware, Newark, Delaware 19716, United States
| | - Adam C Abraham
- Department of Orthopedic Surgery, Columbia University Medical Center, New York, New York 10032, United States
| | - Megan L Killian
- Department of Biomedical Engineering, University of Delaware, Newark, Delaware 19716, United States
| |
Collapse
|
25
|
Mengsteab PY, Nair LS, Laurencin CT. The past, present and future of ligament regenerative engineering. Regen Med 2016; 11:871-881. [PMID: 27879170 DOI: 10.2217/rme-2016-0125] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
Regenerative engineering has been defined as the convergence of Advanced Materials Sciences, Stem Cell Sciences, Physics, Developmental Biology and Clinical Translation for the regeneration of complex tissues and organ systems. Anterior cruciate ligament (ACL) reconstruction necessitates the regeneration of bone, ligament and their interface to achieve superior clinical results. In the past, the ACL has been repaired with the use of autologous and allogeneic grafts, which have their respective drawbacks. Currently, investigations on the use of biodegradable matrices to achieve knee stability and permit tissue regeneration are making promising advancements. In the future, utilizing regenerative biology cues to induce an endogenous regenerative response may aid the enhancement of clinical ACL reconstruction outcomes.
Collapse
Affiliation(s)
- Paulos Y Mengsteab
- Institute for Regenerative Engineering, University of Connecticut Health, Farmington, CT 06030, USA.,Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA.,Raymond & Beverly Sackler Center for Biomedical, Biological, Physical & Engineering Sciences, University of Connecticut Health, Farmington, CT 06030, USA.,Department of Orthopaedic Surgery, University of Connecticut Health, Farmington, CT 06030, USA
| | - Lakshmi S Nair
- Institute for Regenerative Engineering, University of Connecticut Health, Farmington, CT 06030, USA.,Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA.,Raymond & Beverly Sackler Center for Biomedical, Biological, Physical & Engineering Sciences, University of Connecticut Health, Farmington, CT 06030, USA.,Department of Orthopaedic Surgery, University of Connecticut Health, Farmington, CT 06030, USA.,Department of Materials Science & Engineering, University of Connecticut, Storrs, CT 06269, USA.,Department of Chemical & Biomolecular Engineering, University of Connecticut, Storrs, CT 06269, USA
| | - Cato T Laurencin
- Institute for Regenerative Engineering, University of Connecticut Health, Farmington, CT 06030, USA.,Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA.,Raymond & Beverly Sackler Center for Biomedical, Biological, Physical & Engineering Sciences, University of Connecticut Health, Farmington, CT 06030, USA.,Department of Orthopaedic Surgery, University of Connecticut Health, Farmington, CT 06030, USA.,Department of Materials Science & Engineering, University of Connecticut, Storrs, CT 06269, USA.,Department of Chemical & Biomolecular Engineering, University of Connecticut, Storrs, CT 06269, USA.,Department of Craniofacial Sciences, School of Dental Medicine, University of Connecticut Health, Farmington, CT 06030, USA
| |
Collapse
|
26
|
Cury DP, Dias FJ, Miglino MA, Watanabe IS. Structural and Ultrastructural Characteristics of Bone-Tendon Junction of the Calcaneal Tendon of Adult and Elderly Wistar Rats. PLoS One 2016; 11:e0153568. [PMID: 27078690 PMCID: PMC4831835 DOI: 10.1371/journal.pone.0153568] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2015] [Accepted: 03/31/2016] [Indexed: 11/26/2022] Open
Abstract
Tendons are transition tissues that transfer the contractile forces generated by the muscles to the bones, allowing movement. The region where the tendon attaches to the bone is called bone-tendon junction or enthesis and may be classified as fibrous or fibrocartilaginous. This study aims to analyze the collagen fibers and the cells present in the bone-tendon junction using light microscopy and ultrastructural techniques as scanning electron microscopy and transmission electron microscopy. Forty male Wistar rats were used in the experiment, being 20 adult rats at 4 months-old and 20 elderly rats at 20 months-old. The hind limbs of the rats were removed, dissected and prepared to light microscopy, transmission electron microscopy and scanning electron microscopy. The aging process showed changes in the collagen fibrils, with a predominance of type III fibers in the elderly group, in addition to a decrease in the amount of the fibrocartilage cells, fewer and shorter cytoplasmic processes and a decreased synthetic capacity due to degradation of the organelles involved in synthesis.
Collapse
Affiliation(s)
- Diego Pulzatto Cury
- Department of Anatomy, Institute of Biomedical Sciences, University of São Paulo, São Paulo, Brazil
- Department of Surgery, School of Veterinary Medicine and Animal Science, University of São Paulo, São Paulo, Brazil
| | - Fernando José Dias
- Department of Surgery and Anatomy, School of Medicine of Ribeirão Preto, University of São Paulo, Ribeirão Preto, Brazil
- CICO Research Centre, Dental School, Universidad de La Frontera, Temuco, Chile
| | - Maria Angélica Miglino
- Department of Surgery, School of Veterinary Medicine and Animal Science, University of São Paulo, São Paulo, Brazil
| | - Ii-sei Watanabe
- Department of Anatomy, Institute of Biomedical Sciences, University of São Paulo, São Paulo, Brazil
- Department of Surgery, School of Veterinary Medicine and Animal Science, University of São Paulo, São Paulo, Brazil
- * E-mail:
| |
Collapse
|
27
|
Vidal BDC, Dos Anjos EHM, Mello MLS. Optical anisotropy reveals molecular order in a mouse enthesis. Cell Tissue Res 2015; 362:177-85. [PMID: 25866201 DOI: 10.1007/s00441-015-2173-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2014] [Accepted: 03/18/2015] [Indexed: 01/07/2023]
Abstract
Entheses are specialized biological structures that functionally anchor tendons to bones. The complexity, mechanical characteristics and properties of the entheses, particularly those related to exercise, mechanical load and pathologies, have been extensively analyzed; however, the macromolecular organization of the enthesis fibers, as assessed by polarization microscopy, has not yet been investigated. Morphological and optical anisotropy characteristics, such as birefringence, linear dichroism (LD) and differential interference contrast (DIC-PLM) properties, are thus analyzed in this study of a healthy adult mouse calcaneal tendon-bone enthesis. The molecular and supramolecular order of collagen and GAGs was determined for the collagen bundles of this enthesis. Based on a birefringence plot pattern as well as on metachromasy and linear dichroism after toluidine blue staining at pH 4.0, a similarity between the calcaneal tendon-bone enthesis and cartilage during ossification may be assumed. This similarity is assumed to favor the adequacy of this enthesis to support a compressive load. Considering that the collagen-proteoglycan complexes and the enthesis fibers themselves have a chiral nature, these structures could be acting via reciprocal signaling with the cellular environment of the enthesis.
Collapse
Affiliation(s)
- Benedicto de Campos Vidal
- Department of Structural and Functional Biology, Institute of Biology, University of Campinas (Unicamp), 13083-862, Campinas, SP, Brazil.
| | - Eli Heber M Dos Anjos
- Department of Structural and Functional Biology, Institute of Biology, University of Campinas (Unicamp), 13083-862, Campinas, SP, Brazil
| | - Maria Luiza S Mello
- Department of Structural and Functional Biology, Institute of Biology, University of Campinas (Unicamp), 13083-862, Campinas, SP, Brazil
| |
Collapse
|
28
|
Zhao L, Thambyah A, Broom N. Crimp morphology in the ovine anterior cruciate ligament. J Anat 2015; 226:278-88. [PMID: 25677165 DOI: 10.1111/joa.12276] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/15/2014] [Indexed: 11/30/2022] Open
Abstract
While the crimp morphology in ligaments and tendons has been described in detail in the literature, its relative distribution within the tissue has not been studied, especially in relation to the complex multi-bundle arrangement as is found in the anterior cruciate ligament (ACL). In this study, the crimp morphology of the ovine ACL was examined topologically and with respect to its double-bundle structure. The crimp morphologies were compared with the knee in three knee positions, namely stance, maximum extension and maximum flexion. As a control, the crimp morphology of the ACL free from its bony attachments was determined. In the control samples, the anterior-medial (AM) bundle contained a combination of coarse and fine crimp, whereas the posterior-lateral (PL) bundle manifested only a coarse crimp. Using the extent of crimp loss observed when subjecting the knee to the respective positions, and comparing with the controls, the crimp morphologies show that the AM bundle of the ACL is most active in the stance position, whereas for the maximum extension and flexion positions the PL bundle is most active. We propose that these differences in crimp morphologies have relevance to ACL design and function.
Collapse
Affiliation(s)
- Lei Zhao
- Experimental Tissue Mechanics Laboratory, Department of Chemical and Materials Engineering, University of Auckland, Auckland, New Zealand
| | | | | |
Collapse
|