1
|
Türksayar AAD, Petersmann S, Spintzyk S. The effect of thermomechanical aging on the fracture resistance of additive and subtractive manufactured polyetheretherketone abutments. J Dent 2024:105225. [PMID: 38969266 DOI: 10.1016/j.jdent.2024.105225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2024] [Revised: 06/26/2024] [Accepted: 07/02/2024] [Indexed: 07/07/2024] Open
Abstract
OBJECTIVES To evaluate the fracture resistance (FR) of polyetheretherketone (PEEK) abutments produced by additive and subtractive methods compared to milled zirconia abutments. METHODS Custom abutments were designed on Ti-base abutments and produced from three different materials, namely additively manufactured PEEK (PEEK-AM), subtractively manufactured PEEK (PEEK-SM), and zirconia (N=60). PEEK-AM abutments were printed using PEEK filaments (VESTAKEEP®i4 3DF-T, Evonik Industries AG) on a M150 Medical 3D Printer (ORION AM) by fused filament fabrication (FFF). All surface treatments were carried out according to the manufacturer's instructions. All abutments were cemented on Ti-bases with hybrid abutment cement and then restored with milled zirconia crowns. Each subgroup was divided into non-aged and aged subgroups (n=10). The aged groups were subjected to thermomechanical aging (49 N, 5-55°C, 1.2 million cycles). FR tests were performed by using a universal testing machine. Data were statistically analyzed with one-way and two-way ANOVA and t-test. RESULTS The survival rate of the specimens after aging was determined as 100%. It was found that both the material and aging had a significant effect on the FR (p<.001). There was a statistical difference among the fracture values of the groups (p<0.001). In both the aged and non-aged groups, PEEK-AM showed the statistically lowest FR, while the highest FR was seen in the zirconia group, which was significantly higher than the PEEK-SM (p<0.001). CONCLUSION Hybrid abutments were successfully manufactured, and extrusion-based processed PEEK seems to be a good alternative to subtractive processed PEEK. However, since subtractive manufacturing still appears to be superior, further developments in additive manufacturing are needed to further improve the quality of 3D-printed PEEK parts, especially in terms of accuracy and bonding between adjacent layers. CLINICAL SIGNIFICANCE Additively manufactured PEEK abutments have the potential to be an alternative for implant-supported restorations in the posterior region.
Collapse
Affiliation(s)
- Almira Ada Diken Türksayar
- Department of Prosthodontics, Biruni University, Faculty of Dentistry, İstanbul, Turkey; ADMiRE Research Center, Carinthia University of Applied Sciences, Europastrasse, 9524 Villach, Austria.
| | - Sandra Petersmann
- ADMiRE Research Center, Carinthia University of Applied Sciences, Europastrasse, 9524 Villach, Austria
| | - Sebastian Spintzyk
- ADMiRE Research Center, Carinthia University of Applied Sciences, Europastrasse, 9524 Villach, Austria
| |
Collapse
|
2
|
Chuchulska B, Dimitrova M, Vlahova A, Hristov I, Tomova Z, Kazakova R. Comparative Analysis of the Mechanical Properties and Biocompatibility between CAD/CAM and Conventional Polymers Applied in Prosthetic Dentistry. Polymers (Basel) 2024; 16:877. [PMID: 38611135 PMCID: PMC11013798 DOI: 10.3390/polym16070877] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2024] [Revised: 03/14/2024] [Accepted: 03/19/2024] [Indexed: 04/14/2024] Open
Abstract
Modern media often portray CAD/CAM technology as widely utilized in the fabrication of dental prosthetics. This study presents a comparative analysis of the mechanical properties and biocompatibility of CAD/CAM (Computer-Aided Design/Computer-Aided Manufacturing) polymers and conventional polymers commonly utilized in prosthetic dentistry. With the increasing adoption of CAD/CAM technology in dental laboratories and practices, understanding the differences in material properties is crucial for informed decision-making in prosthodontic treatment planning. Through a narrative review of the literature and empirical data, this study evaluates the mechanical strength, durability, esthetics, and biocompatibility of CAD/CAM polymers in comparison to traditional polymers. Furthermore, it examines the implications of these findings on the clinical outcomes and long-term success of prosthetic restorations. The results provide valuable insights into the advantages and limitations of CAD/CAM polymers, informing clinicians and researchers about their suitability for various dental prosthetic applications. This study underscores the considerable advantages of CAD/CAM polymers over conventional ones in terms of mechanical properties, biocompatibility, and esthetics for prosthetic dentistry. CAD/CAM technology offers improved mechanical strength and durability, potentially enhancing the long-term performance of dental prosthetics, while the biocompatibility of these polymers makes them suitable for a broad patient demographic, reducing the risk of adverse reactions. The practical implications of these findings for dental technicians and dentists are significant, as understanding these material differences enables tailored treatment planning to meet individual patient needs and preferences. Integration of CAD/CAM technology into dental practices can lead to more predictable outcomes and heightened patient satisfaction with prosthetic restorations.
Collapse
Affiliation(s)
- Bozhana Chuchulska
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
| | - Mariya Dimitrova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
| | - Angelina Vlahova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
- CAD/CAM Center of Dental Medicine, Research Institute, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| | - Ilian Hristov
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
| | - Zlatina Tomova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
| | - Rada Kazakova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
- CAD/CAM Center of Dental Medicine, Research Institute, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| |
Collapse
|
3
|
Lin L, Zhuo Y, Cai P, Chen X, Zheng Z, Lin J. Use of an intraoral scanner and CAD-CAM for simultaneous restoration with a personalized titanium post-core and a zirconia crown. J Oral Sci 2024; 66:82-84. [PMID: 37866924 DOI: 10.2334/josnusd.23-0186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2023]
Abstract
Customized posts-and-cores have been widely used for improved fitness within a prepared post space. However, in comparison to direct restoration, they necessitate an increased number of appointments for patients. A 24-year-old man presented with a maxillary left canine that had fractured due to trauma 10 months previously. For this case, a digital process was used for simultaneous restoration with a personalized titanium post-and-core and a zirconia crown achieved with an intraoral scanner (IOS) and computer-aided design/computer-aided manufacturing (CAD-CAM). This workflow allowed the restoration to be completed in 2 visits, facilitating more effective and predictable treatment, with reduced time and cost for the patient.
Collapse
Affiliation(s)
- Ling Lin
- Fujian Key Laboratory of Oral Diseases, School and Hospital of Stomatology, Fujian Medical University
| | - Yingying Zhuo
- Fujian Key Laboratory of Oral Diseases, School and Hospital of Stomatology, Fujian Medical University
| | - Pingping Cai
- Fujian Key Laboratory of Oral Diseases, School and Hospital of Stomatology, Fujian Medical University
| | - Xi Chen
- Fujian Key Laboratory of Oral Diseases, School and Hospital of Stomatology, Fujian Medical University
| | - Zhiqiang Zheng
- Fujian Key Laboratory of Oral Diseases, School and Hospital of Stomatology, Fujian Medical University
| | - Jie Lin
- Fujian Key Laboratory of Oral Diseases, School and Hospital of Stomatology, Fujian Medical University
- Department of Crown and Bridge, School of Life Dentistry at Tokyo, The Nippon Dental University
| |
Collapse
|
4
|
Dimitrova M, Vlahova A, Kalachev Y, Zlatev S, Kazakova R, Capodiferro S. Recent Advances in 3D Printing of Polymers for Application in Prosthodontics. Polymers (Basel) 2023; 15:4525. [PMID: 38231950 PMCID: PMC10708542 DOI: 10.3390/polym15234525] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Revised: 11/15/2023] [Accepted: 11/22/2023] [Indexed: 01/19/2024] Open
Abstract
Contemporary mass media frequently depict 3D printing as a technology with widespread utilization in the creation of dental prosthetics. This paper endeavors to provide an evidence-based assessment of the current scope of 3D printing's integration within dental laboratories and practices. Its primary objective is to offer a systematic evaluation of the existing applications of 3D-printing technology within the realm of dental prosthetic restorations. Furthermore, this article delves into potential prospects, while also critically examining the sustained relevance of conventional dental laboratory services and manufacturing procedures. The central focus of this article is to expound upon the extent to which 3D printing is presently harnessed for crafting dental prosthetic appliances. By presenting verifiable data and factual insights, this article aspires to elucidate the actual implementation of 3D printing in prosthetic dentistry and its seamless integration into dental practices. The aim of this narrative review is twofold: firstly, to provide an informed and unbiased evaluation of the role that 3D printing currently plays within dental laboratories and practices; and secondly, to instigate contemplation on the transformative potential of this technology, both in terms of its contemporary impact and its future implications, while maintaining a balanced consideration of traditional dental approaches.
Collapse
Affiliation(s)
- Mariya Dimitrova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (Y.K.); (S.Z.); (R.K.)
| | - Angelina Vlahova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (Y.K.); (S.Z.); (R.K.)
- CAD/CAM Center of Dental Medicine, Research Institute, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| | - Yavor Kalachev
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (Y.K.); (S.Z.); (R.K.)
| | - Stefan Zlatev
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (Y.K.); (S.Z.); (R.K.)
- CAD/CAM Center of Dental Medicine, Research Institute, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| | - Rada Kazakova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (Y.K.); (S.Z.); (R.K.)
- CAD/CAM Center of Dental Medicine, Research Institute, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| | - Saverio Capodiferro
- Department of Interdisciplinary Medicine, Aldo Moro, University of Bari, 70100 Bari, Italy;
| |
Collapse
|
5
|
Lyu X, Kanda R, Tsuda S, Hashimoto Y, Fujii T, Kashiwagi K. Novel Carboxylation Method for Polyetheretherketone (PEEK) Surface Modification Using Friedel-Crafts Acylation. Int J Mol Sci 2023; 24:15651. [PMID: 37958636 PMCID: PMC10650194 DOI: 10.3390/ijms242115651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 10/23/2023] [Accepted: 10/25/2023] [Indexed: 11/15/2023] Open
Abstract
Recently, polyetheretherketone (PEEK) has shown promising dental applications. Surface treatment is essential for dental applications owing to its poor surface energy and wettability; however, no consensus on an effective treatment method has been achieved. In this study, we attempted to carboxylate PEEK sample surfaces via Friedel-Crafts acylation using succinic anhydride and AlBr3. The possibility of further chemical modifications using carboxyl groups was examined. The samples were subjected to dehydration-condensation reactions with 1H,1H-pentadecafluorooctylamine and N,N'-dicyclohexylcarbodiimide. Furthermore, the sample's surface properties at each reaction stage were evaluated. An absorption band in the 3300-3500 cm-1 wavenumber region was observed. Additionally, peak suggestive of COOH was observed in the sample spectra. Secondary modification diminished the absorption band in 3300-3500 cm-1 and a clear F1s signal was observed. Thus, Friedel-Crafts acylation with succinic anhydride produced carboxyl groups on the PEEK sample surfaces. Further chemical modification of the carboxyl groups by dehydration-condensation reactions is also possible. Thus, a series of reactions can be employed to impart desired chemical structures to PEEK surfaces.
Collapse
Affiliation(s)
- Xinghui Lyu
- Department of Fixed Prosthodontics and Occlusion, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan; (X.L.); (T.F.); (K.K.)
| | - Ryuhei Kanda
- Division of Creative and Integrated Medicine, Advanced Medicine Research Center, Translational Research Institute for Medical Innovation (TRIMI), Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan;
| | - Susumu Tsuda
- Department of Chemistry, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan;
| | - Yoshiya Hashimoto
- Division of Creative and Integrated Medicine, Advanced Medicine Research Center, Translational Research Institute for Medical Innovation (TRIMI), Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan;
- Department of Biomaterial, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan
| | - Takamasa Fujii
- Department of Fixed Prosthodontics and Occlusion, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan; (X.L.); (T.F.); (K.K.)
| | - Kosuke Kashiwagi
- Department of Fixed Prosthodontics and Occlusion, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan; (X.L.); (T.F.); (K.K.)
| |
Collapse
|
6
|
Almohareb T, Al Ahdal K, Maawadh AM, Alshamrani AS, El Mourad AM, Al-Bishry FY, Alrahlah A. Poly-Ether Ether-Ketone Post Conditioned with Sulfuric Acid, Rose Bengal Activated by Photodynamic Therapy and Sandblasting on Pushout Bond Strength to Radicular Dentin Luted with Methyl Methacrylate and Composite-Based Cement. Photobiomodul Photomed Laser Surg 2023; 41:576-582. [PMID: 37870415 DOI: 10.1089/photob.2023.0079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2023] Open
Abstract
Objective: Assessment of post surface conditioners [sulfuric acid (SA), Rose Bengal (RB), and sandblasting (SB)] and different luting cements [methyl methacrylate (MMA)-based cement and composite-based cement] on pushout bond strength (PBS) of poly-ether ether-ketone (PEEK) post bonded to canal dentin. Materials and methods: Endodontic treatment was performed on 120 single-rooted human premolar teeth. The preparation of the post space was performed and 4 mm of gutta-percha was retained in the apical region of the root. One hundred and twenty PEEK posts were fabricated from a PEEK blank utilizing a Computer aided design-Computer aided manufacture (CAD-CAM) system. The PEEK posts were allocated randomly into four groups based on post surface conditioning (n = 30). Group A: SA, Group B: RB, Group C: SB, and Group D: No conditioning (NC). Each group was further divided into two subgroups based on the luting cement used for bonding (n = 15). Group A1, B1, C1, and D1 specimens were cemented using composite-based resin cement. However, Group A2, B2, C2, and D2 posts were luted with MMA-based resin cement. PBS assessment using a universal testing machine was performed. Failure modes were analyzed under a stereomicroscope. The data relating to the effects of surface treatment and luting types of cement were analyzed using one-way analysis of variance (ANOVA) and Tukey's post hoc test (p = 0.05). Results: Coronal section of Group B2: RB+Super-Bond C&B [9.61 ± 0.75 megapascals (MPa)] displayed the highest bond scores of PEEK after root dentin. Whereas it was also discovered that Group D1: NC+Panavia®V5 (2.05 ± 0.72 MPa) presented the lowest PBS scores. Intergroup comparison analysis revealed that Group A2: SA+Super-Bond C&B and Group B2: RB+Super-Bond C&B displayed no significant difference in their bond scores. Conclusions: RB and SA possess the potential to be used as a PEEK post conditioner. MMA-based cement displayed better performance than composite-based cement.
Collapse
Affiliation(s)
- Thamer Almohareb
- Operative Division, Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudia Arabia
| | - Khold Al Ahdal
- Operative Division, Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudia Arabia
| | - Ahmed M Maawadh
- Operative Division, Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudia Arabia
| | - Ahoud S Alshamrani
- Operative Division, Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudia Arabia
| | - Aminah M El Mourad
- Operative Division, Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudia Arabia
| | - Fatima Y Al-Bishry
- Consultant-Special Care Clinic, King Saud University Medical City, Riyadh, Saudi Arabia
| | - Ali Alrahlah
- Operative Division, Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudia Arabia
| |
Collapse
|
7
|
Zhao T, Jiang Z, Ge Y, Yin H, Yang Q, Li R, Chen Z, Zhang H, Liu X. Mechanical properties, biosafety, and shearing bonding strength of glass fiber-reinforced PEEK composites used as post-core materials. J Mech Behav Biomed Mater 2023; 145:106047. [PMID: 37523841 DOI: 10.1016/j.jmbbm.2023.106047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 07/24/2023] [Accepted: 07/26/2023] [Indexed: 08/02/2023]
Abstract
OBJECTIVE To investigate the mechanical properties, biosafety, and shearing bonding strength of glass fibers-reinforced polyether-ether-ketone (PEEK-GF) for post-core materials. METHODS PEEK-GF composites with different glass fiber contents were prepared by extrusion injection and named PEEK-GF30, PEEK-GF40, and PEEK-GF50. Mechanical properties including flexural modulus, flexural strength, Vickers hardness, and compression strength were tested. The cross-sectional morphology was examined using scanning electron microscopy (SEM). Cytotoxicity was studied in vitro with Cell-counting kit-8 (CCK-8). Cell morphology was observed under a microscope. Cell growth on the composites' surfaces was analyzed with DAPI staining. The shearing bonding strength (SBS) of PEEK-GF50 was assessed after applying different pretreatments. Failure modes were evaluated by microscopy. SEM and contact-angle measurements were performed on the surfaces. Statistical analysis was conducted using one-way ANOVA (P < 0.05). RESULTS The mechanical properties of PEEK-GF composites improved with increased GF content. The PEEK-GF50 group exhibited flexural modulus (17.4 ± 0.5 GPa) close to that of dentin (18.6 GPa) and showed the highest flexural strength (350.0 ± 2.9 MPa), Vickers hardness (47.6 ± 4.5 HV), and compressive strength (264.0 ± 18.0 MPa). The SEM analysis demonstrated that the PEEK matrix combined well with glass fibers. The CCK-8 results confirmed the biosafety of all groups. DAPI staining indicated that cells were growing well on the composites' surface. The sample that was pretreated with sandblasting and plasma showed the highest SBS (16.0 ± 1.7 MPa). SIGNIFICANCE The PEEK-GF composites demonstrated excellent mechanical properties, biosafety, and SBS, and have great potential to serve as post-core materials.
Collapse
Affiliation(s)
- Ting Zhao
- Department of Geriatric Dentistry, Hospital of Stomatology, Jilin University, China
| | - Zilong Jiang
- National and Local Joint Engineering Laboratory for Synthetic Technology of High-Performance Polymer, College of Chemistry, Jilin University, China
| | - Yongcheng Ge
- Department of Geriatric Dentistry, Hospital of Stomatology, Jilin University, China
| | - Haoyu Yin
- Department of Geriatric Dentistry, Hospital of Stomatology, Jilin University, China
| | - Qi Yang
- Department of Geriatric Dentistry, Hospital of Stomatology, Jilin University, China
| | - Ruozhu Li
- Department of Pediatric Dentistry, Hospital of Stomatology, Jilin University, China
| | - Zheng Chen
- National and Local Joint Engineering Laboratory for Synthetic Technology of High-Performance Polymer, College of Chemistry, Jilin University, China
| | - Haibo Zhang
- National and Local Joint Engineering Laboratory for Synthetic Technology of High-Performance Polymer, College of Chemistry, Jilin University, China.
| | - Xiaoqiu Liu
- Department of Geriatric Dentistry, Hospital of Stomatology, Jilin University, China.
| |
Collapse
|
8
|
Alkhudhairy F, Aljamhan AS. Surface conditioning of PEEK post using Nd: YVO4 laser, Photodynamic therapy, and sulfuric acid on the pushout bond strength to canal dentin. Photodiagnosis Photodyn Ther 2023; 42:103601. [PMID: 37169168 DOI: 10.1016/j.pdpdt.2023.103601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Revised: 05/05/2023] [Accepted: 05/08/2023] [Indexed: 05/13/2023]
Abstract
AIM To assess the push-out bond strength (PBS) of polyetheretherketone (PEEK) post-to-root dentin using post-surface conditioners i.e., Neodymium-doped yttrium orthovanadate (Nd: YVO4) and Riboflavin (RF) and Rose Bengal (RB) mediated photodynamic therapy (PDT) compared to sulfuric acid (SA). MATERIALS AND METHODS Decoronation of forty human single-rooted premolar teeth was performed. Followed by chamber opening, working length (WL) was established at 15 mm. Root canal preparation was completed using ProTaper Ni-Ti rotary system till F3 finishing file along with root canal disinfection. The canals were dried with paper cones followed by obturation using gutta-percha (GP) and AH sealer. Post space was prepared by drilling out 11 mm of GP using a Gates Glidden drill #3. PEEK posts were fabricated using the CAD-CAM system and then randomly allocated into 4 groups based on the post-surface conditioning (n=10). Group 1: SA, group 2: PDT RF, group 3: PDT RB, and group 4: Nd: YVO4 laser. The PEEK post was then cemented in their respective canal. PBS and failure mode assessment were performed using a universal testing machine and stereomicroscope at 40x magnification. The SBS data set was subjected to a one-way analysis of variance (ANOVA) and Tukey's Post Hoc test at a significance level of 0.05. RESULTS The samples in group 4 (Nd: YVO4 laser) coronal third (7.99±0.24 MPa) demonstrated the highest PBS. The apical third of samples in group 1 PEEK post surface conditioned with SA (5.15± 0.52 MPa) exhibited the minimum values of PBS. Intergroup comparison analysis showed that samples in group 1 (SA), group 2 (RF activated by PDT), group 3 (RB activated by PDT), and group 4 (Nd: YVO4 laser) demonstrated comparable outcomes of bond scores (p>0.05) CONCLUSION: Neodymium-doped yttrium orthovanadate (Nd: YVO4) and riboflavin and Rose bengal activated by photodynamic therapy (PDT) have been investigated as potential alternatives for the surface conditioning of PEEK (polyetheretherketone) posts.
Collapse
Affiliation(s)
- Fahad Alkhudhairy
- Restorative Dental Sciences Department, College of Dentistry, King Saud University, Riyadh, Saudi Arabia.
| | - Abdullah S Aljamhan
- Restorative Dental Sciences Department, College of Dentistry, King Saud University, Riyadh, Saudi Arabia.
| |
Collapse
|
9
|
Miura D, Ishida Y, Shinya A. The Effects of Different Molding Orientations, Highly Accelerated Aging, and Water Absorption on the Flexural Strength of Polyether Ether Ketone (PEEK) Fabricated by Fused Deposition Modeling. Polymers (Basel) 2023; 15:polym15071602. [PMID: 37050216 PMCID: PMC10096610 DOI: 10.3390/polym15071602] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 03/10/2023] [Accepted: 03/10/2023] [Indexed: 04/14/2023] Open
Abstract
Rising prices are currently a problem in the world. In particular, the abnormal increases in the price of metals, which are often used in dental prosthetics, have increased the burden of dental costs on the public. There is therefore an urgent need to develop prosthetic devices made from materials that are not affected by the global situation and that have excellent biocompatibility and mechanical properties comparable to those of metals. Polyether ether ketone (PEEK) is a promising alternative to metal in dentistry. This study compared the effects of different molding orientations, highly accelerated aging, and water absorption on the flexural strength of PEEK fabricated by fused deposition modeling (FDM) and examined its potential for dental applications. The flexural strength of PEEK stacked at 0° to the molding stage (0° PF), with and without highly accelerated aging, was significantly greater than for the other molding orientations. As with PD, the maximum test load for 0° PF was measured without fracture. PEEK stacked at 45° (45° PF) and 90° (90° PF) to the molding stage easily fractured, as the applied load pulled the stacked layers. No statistically significant difference was found between the flexural strength of 45° PF and 90° PF. The flexural strength decreased under all conditions due to defects in the crystal structure of PEEK caused by highly accelerated aging.
Collapse
Affiliation(s)
- Daisuke Miura
- Department of Dental Materials Science, School of Life Dentistry at Tokyo, The Nippon Dental University, 1-9-20 Fujimi, Chiyoda-ku, Tokyo 102-8159, Japan
| | - Yoshiki Ishida
- Department of Dental Materials Science, School of Life Dentistry at Tokyo, The Nippon Dental University, 1-9-20 Fujimi, Chiyoda-ku, Tokyo 102-8159, Japan
| | - Akikazu Shinya
- Department of Dental Materials Science, School of Life Dentistry at Tokyo, The Nippon Dental University, 1-9-20 Fujimi, Chiyoda-ku, Tokyo 102-8159, Japan
- Turku Biomaterials Research Program, Department of Biomaterials Science, Institute of Dentistry and BioCity, University of Turku, 20500 Turku, Finland
| |
Collapse
|
10
|
Igarashi K, Katagiri H, Abou-Ayash S, Schimmel M, Afrashtehfar KI. Double-Crown Prosthesis Retention Using Polyetherketoneketone (PEKK): An In Vitro Study. J Prosthodont 2023; 32:154-161. [PMID: 35343624 DOI: 10.1111/jopr.13512] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Accepted: 03/23/2022] [Indexed: 11/29/2022] Open
Abstract
PURPOSE To assess the retentive force of telescopic crowns using polyetherketoneketone (PEKK) high-performance polymer in relation to conventional materials over a long period of time in an in vitro setting. MATERIALS AND METHODS Thirty-six sets of primary and secondary crowns were fabricated as per the double crown-retained prostheses approach. Six samples were included in each of the five test groups (1: zirconia/PEKK [Zr/PEKK]; 2: titanium/PEKK [Ti/PEKK]; 3: cobalt-chrome/PEKK [CoCr/PEKK]; 4: PEKK/PEKK; and 5: gold/PEKK [Au/PEKK]) and the single control group (gold/galvano-gold [Au/GA]). The insertion-removal test was performed for 20,000 cycles, and the surface condition was observed. Retentive forces were analyzed using two-way ANOVA (α<0.05). RESULTS The retention forces in groups Zr/PEKK and Ti/PEKK significantly decreased over time (group 1: p = 0.035 and group 2: p = 0.001), whereas retentive force increased significantly in groups PEKK/PEKK, Au/PEKK, and control (group 4: p = 0.001, group 5: p = 0.008, and control: p = 0.042). Similar wear was observed on the primary crown in groups PEKK/PEKK, gold/PEKK, and control. CONCLUSIONS Groups PEKK/PEKK and Au/PEKK showed a transition of retentive force similar to the control group. Groups PEKK/PEKK and Au/PEKK had similar wear on the surface compared to control. Therefore, PEKK has a promising clinical potential.
Collapse
Affiliation(s)
- Kensuke Igarashi
- Department of Dental Materials Science, The Nippon Dental University, School of Life Dentistry at Niigata, Niigata, Japan
| | - Hiroki Katagiri
- Advanced Research Center, The Nippon Dental University, School of Life Dentistry at Niigata, Niigata, Japan.,Department of Histology, The Nippon Dental University, School of Life Dentistry at Niigata, Niigata, Japan
| | - Samir Abou-Ayash
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.,Division of Gerodontology and Removable Prosthodontics, University of Geneva, Geneva, Switzerland
| | - Kelvin I Afrashtehfar
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.,Clinical Sciences Department, Ajman University College of Dentistry, Ajman Emirate, UAE.,School of Biomedical and Health Sciences, Universidad Europea de Madrid, Madrid, Spain
| |
Collapse
|
11
|
The Use of Polyetheretherketone (PEEK) as an Alternative Post and Core Material: Five-Year Follow-Up Report. Dent J (Basel) 2022; 10:dj10120237. [PMID: 36547053 PMCID: PMC9776542 DOI: 10.3390/dj10120237] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 12/05/2022] [Accepted: 12/07/2022] [Indexed: 12/14/2022] Open
Abstract
This clinical report demonstrated the use of polyetheretherketone (PEEK) for manufacturing of custom-made post and core in weakened endodontically treated central incisors. The PEEK structure was manufactured using computer-aided design/computer-aided manufacturing (CAD/CAM). The optimal fit of this custom-made endodontic post allowed a thinner cement layer; and removed the need to manufacture a core build-up. While supplementary clinical trials and in vitro studies are needed to totally elucidate the advantages and limitations of PEEK as an option for post and core manufacturing, this case report showed that it can be promising for a predictable and simplified treatment with five years of success.
Collapse
|
12
|
Liu Y, Fang M, Zhao R, Liu H, Li K, Tian M, Niu L, Xie R, Bai S. Clinical Applications of Polyetheretherketone in Removable Dental Prostheses: Accuracy, Characteristics, and Performance. Polymers (Basel) 2022; 14:polym14214615. [PMID: 36365609 PMCID: PMC9654455 DOI: 10.3390/polym14214615] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 10/19/2022] [Accepted: 10/25/2022] [Indexed: 11/06/2022] Open
Abstract
The high-performance thermoplastic polyetheretherketone (PEEK) has excellent mechanical properties, biocompatibility, chemical stability, and radiolucency. The present article comprehensively reviews various applications of PEEK in removable dental prostheses, including in removable partial dentures (RPDs) (frameworks and clasps), double-crown RPDs, and obturators. The clinical performance of PEEK in removable dental prostheses is shown to be satisfactory and promising based on the short-term clinical evidence and technical complications are scarce. Moreover, the accuracy of RPDs is a vital factor for their long-term success rate. PEEK in removable dental prostheses is fabricated using the conventional lost-wax technique and CAD/CAM milling, which produces a good fit. Furthermore, fused deposition modeling is considered to be one of the most practical additive techniques. PEEK in removable prostheses produced by this technique exhibits good results in terms of the framework fit. However, in light of the paucity of evidence regarding other additive techniques, these manufacturers cannot yet be endorsed. Surface roughness, bacterial retention, color stability, and wear resistance should also be considered when attempting to increase the survival rates of PEEK removable prostheses. In addition, pastes represent an effective method for PEEK polishing to obtain a reduced surface roughness, which facilitates lower bacterial retention. As compared to other composite materials, PEEK is less likely to become discolored or deteriorate due to wear abrasion.
Collapse
Affiliation(s)
- Yuchen Liu
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Ming Fang
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Correspondence: (M.F.); (S.B.)
| | - Ruifeng Zhao
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Digital Dentistry Center, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Hengyan Liu
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Kangjie Li
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Min Tian
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Lina Niu
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Rui Xie
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Digital Dentistry Center, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
| | - Shizhu Bai
- State Key Laboratory of Military Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- National Clinical Research Center for Oral Diseases, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Shaanxi Key Laboratory of Stomatology, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Digital Dentistry Center, School of Stomatology, The Fourth Military Medical University, Xi’an 710032, China
- Correspondence: (M.F.); (S.B.)
| |
Collapse
|
13
|
Wang B, Huang M, Dang P, Xie J, Zhang X, Yan X. PEEK in Fixed Dental Prostheses: Application and Adhesion Improvement. Polymers (Basel) 2022; 14:polym14122323. [PMID: 35745900 PMCID: PMC9228596 DOI: 10.3390/polym14122323] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 06/06/2022] [Accepted: 06/07/2022] [Indexed: 01/27/2023] Open
Abstract
Polyetheretherketone (PEEK) has been widely applied in fixed dental prostheses, comprising crowns, fixed partial dentures, and post-and-core. PEEK’s excellent mechanical properties facilitate better stress distribution than conventional materials, protecting the abutment teeth. However, the stiffness of PEEK is not sufficient, which can be improved via fiber reinforcement. PEEK is biocompatible. It is nonmutagenic, noncytotoxic, and nonallergenic. However, the chemical stability of PEEK is a double-edged sword. On the one hand, PEEK is nondegradable and intraoral corrosion is minimized. On the other hand, the inert surface makes adhesive bonding difficult. Numerous strategies for improving the adhesive properties of PEEK have been explored, including acid etching, plasma treatment, airborne particle abrasion, laser treatment, and adhesive systems.
Collapse
Affiliation(s)
- Biyao Wang
- Liaoning Provincial Key Laboratory of Oral Diseases, The VIP Department, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China; (B.W.); (P.D.); (J.X.)
| | - Minghao Huang
- Liaoning Provincial Key Laboratory of Oral Diseases, Center of Implant Dentistry, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China;
| | - Pengrui Dang
- Liaoning Provincial Key Laboratory of Oral Diseases, The VIP Department, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China; (B.W.); (P.D.); (J.X.)
| | - Jiahui Xie
- Liaoning Provincial Key Laboratory of Oral Diseases, The VIP Department, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China; (B.W.); (P.D.); (J.X.)
| | - Xinwen Zhang
- Liaoning Provincial Key Laboratory of Oral Diseases, Center of Implant Dentistry, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China;
- Correspondence: (X.Z.); (X.Y.); Tel.: +86-024-31927731 (X.Z.); +86-024-31927715 (X.Y.)
| | - Xu Yan
- Liaoning Provincial Key Laboratory of Oral Diseases, The VIP Department, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China; (B.W.); (P.D.); (J.X.)
- Correspondence: (X.Z.); (X.Y.); Tel.: +86-024-31927731 (X.Z.); +86-024-31927715 (X.Y.)
| |
Collapse
|
14
|
Applications and Clinical Behavior of BioHPP in Prosthetic Dentistry: A Short Review. JOURNAL OF COMPOSITES SCIENCE 2022. [DOI: 10.3390/jcs6030090] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
(1) Background: BioHPP® (Bredent, UK) is a partially crystalline poly ether ether ketone (PEEK) that is strengthened using ceramic. PEEK and its various formulations represent a very interesting alternative, and has been in-depth with its literature in recent years; (2) Methods: A PubMed and Scopus search for the term “BioHPP” yielded 73 results and 42 articles which were included in this short review. Considering the scarce literature on the subject, each article was considered in this review; (3) Results: the articles analyzed are very recent, all published in the last 5 years. Their clinical evaluation of BioHPP® highlights many positive aspects, and few articles have highlighted critical issues in its multiple clinical applications; (4) Conclusions: this material is not only extremely interesting for the future, but possesses characteristics suitable for clinical application today, for endocrowns, small adhesive bridges, temporary prostheses and for immediate loads on implant restorations. The excellent aesthetics and the possibility of simple reprocessing of the restorations made with this material invite its clinical application.
Collapse
|