1
|
Vasudevan S, Vogt WC, Weininger S, Pfefer TJ. Melanometry for objective evaluation of skin pigmentation in pulse oximetry studies. COMMUNICATIONS MEDICINE 2024; 4:138. [PMID: 38992188 PMCID: PMC11239860 DOI: 10.1038/s43856-024-00550-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Accepted: 06/11/2024] [Indexed: 07/13/2024] Open
Abstract
Pulse oximetry enables real-time, noninvasive monitoring of arterial blood oxygen levels. However, results can vary with skin color, thus detecting disparities during clinical validation studies requires an accurate measure of skin pigmentation. Recent clinical studies have used subjective methods such as self-reported color, race/ethnicity to categorize skin. Melanometers based on optical reflectance may offer a more effective, objective approach to assess pigmentation. Here, we review melanometry approaches and assess evidence supporting their use as clinical research tools. We compare performance data, including repeatability, robustness to confounders, and compare devices to each other, to subjective methods, and high-quality references. Finally, we propose best practices for evaluating melanometers and discuss alternate optical approaches that may improve accuracy. Whilst evidence indicates that melanometers can provide superior performance to subjective approaches, we encourage additional research and standardization efforts, as these are needed to ensure consistent and reliable results in clinical studies.
Collapse
Affiliation(s)
- Sandhya Vasudevan
- Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave, Silver Spring, MD, 20993, USA.
| | - William C Vogt
- Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave, Silver Spring, MD, 20993, USA
| | - Sandy Weininger
- Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave, Silver Spring, MD, 20993, USA
| | - T Joshua Pfefer
- Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave, Silver Spring, MD, 20993, USA
| |
Collapse
|
2
|
Mancuso A, d’Avanzo N, Cristiano MC, Paolino D. Reflectance spectroscopy: a non-invasive strategy to explore skin reactions to topical products. Front Chem 2024; 12:1422616. [PMID: 38957405 PMCID: PMC11217347 DOI: 10.3389/fchem.2024.1422616] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2024] [Accepted: 05/29/2024] [Indexed: 07/04/2024] Open
Abstract
Reflectance spectroscopy has emerged as a powerful analytical technique in the field of dermatology, offering a non-invasive strategy to assess several cutaneous properties and skin response to topical products. By analyzing reflected light across different wavelengths, reflectance spectroscopy allows the quantification of cutaneous parameters, such as erythema index and melanin content. Moreover, this analytical technique enables the monitoring of any changes in skin physiology facilitating the assessment of long-term effects of topical products as well as predicting cutaneous diseases. This review provides an overview of the application of reflectance spectroscopy in investigating skin properties and reaction to topical applied products, including both pharmaceutical and cosmetic formulations, thereby aiding in the development of personalized solutions tailored to individual needs.
Collapse
Affiliation(s)
- Antonia Mancuso
- Department of Experimental and Clinical Medicine, “Magna Graecia” University of Catanzaro, Catanzaro, Italy
- Research Center “ProHealth Translational Hub”, “Magna Graecia” University of Catanzaro, Catanzaro, Italy
| | - Nicola d’Avanzo
- Department of Experimental and Clinical Medicine, “Magna Graecia” University of Catanzaro, Catanzaro, Italy
- Research Center “ProHealth Translational Hub”, “Magna Graecia” University of Catanzaro, Catanzaro, Italy
| | - Maria Chiara Cristiano
- Department of Medical and Surgical Sciences, “Magna Graecia” University of Catanzaro, Catanzaro, Italy
| | - Donatella Paolino
- Department of Experimental and Clinical Medicine, “Magna Graecia” University of Catanzaro, Catanzaro, Italy
- Research Center “ProHealth Translational Hub”, “Magna Graecia” University of Catanzaro, Catanzaro, Italy
| |
Collapse
|
3
|
Bagheri M, von Kohout M, Fuchs PC, Seyhan H, Stromps JP, Lefering R, Opländer C, Schiefer JL. How to evaluate scar colour after burn injuries - A clinical comparison of the Mexameter® and the subjective scar assessment (POSAS/VSS). Burns 2024; 50:691-701. [PMID: 38097444 DOI: 10.1016/j.burns.2023.11.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 11/17/2023] [Accepted: 11/24/2023] [Indexed: 04/08/2024]
Abstract
INTRODUCTION Scarring after burn injuries remains one of the major challenges in burn medicine and is the subject of current research. Accurate and high-quality assessment of scars is needed to enable exact outcome evaluation of different treatments. Our aim was to evaluate the most common subjective scar evaluation scores-the POSAS (Patient and Observer Scar Assessment Scale) and VSS (Vancouver Scar Scale)-in comparison with the objective device Mexameter® for colour evaluation. METHODS A prospective monocentre study was performed, which included 120 examined scar areas of 60 patients with third degree burns who had received skin grafts between 1975 and 2018 with a total burned surface area (TBSA) > 2%. Two different scar areas in comparison with one healthy skin area concerning 'colour', 'pigmentation', and 'vascularization' were evaluated by the Mexameter® MX 18, the OSAS, and the VSS by the same examiner, as well as the PSAS by the patient. RESULTS The mean TBSA of the 60 patients was 24.3%. In the OSAS, 61% of the scars were evaluated as 'hyper-', 19% as 'hypo-', and 19% as 'mix-pigmented'. Furthermore, 65% of the scars were estimated as highly vascularized. In the Mexameter®, the melanin index values of the scar areas compared to the healthy skin areas showed a small difference of 12 (p < 0.05). The mean difference of erythema between the scar and the healthy skin areas was 84 (p < 0.001). For the Mexameter®, moderate correlations were found when comparing 'erythema' with the OSAS category 'vascularization' (r = 0.33, p < 0.05) and 'melanin' with the OSAS parameter 'pigmentation' (r = 0.28, p < 0.05). When comparing the Mexameter® measurements to the OSAS questionnaire, 27% of the scars were wrongly evaluated as 'hyperpigmented' by the observer and 21% as 'hypervascularized', while showing low measurements in the device. Additionally, a novel Mexameter® ordinal scare scale was calculated. CONCLUSION In this study, we were able to show on a relatively large patient population that with the Mexameter®, the subjectivity of the scar colour assessment by examiner/patient can be overcome, but precise differentiation can still be ensured with subjective evaluation tools. We further introduced a novel Mexameter® Scar Scale. It is necessary to further investigate the vast range of objective devices and develop scar panels for with an incorporation of objective and subjective devices to further improve reliability with reduced bias in terms of scar assessment.
Collapse
Affiliation(s)
- M Bagheri
- Clinic for Plastic and Hand Surgery, Burn Care Center, University of Witten/Herdecke, Cologne Merheim Medical Center (CMMC), Cologne, Germany.
| | - M von Kohout
- Clinic for Plastic and Hand Surgery, Burn Care Center, University of Witten/Herdecke, Cologne Merheim Medical Center (CMMC), Cologne, Germany
| | - P C Fuchs
- Clinic for Plastic and Hand Surgery, Burn Care Center, University of Witten/Herdecke, Cologne Merheim Medical Center (CMMC), Cologne, Germany
| | - H Seyhan
- Clinic for Plastic and Hand Surgery, Burn Care Center, University of Witten/Herdecke, Cologne Merheim Medical Center (CMMC), Cologne, Germany
| | - J P Stromps
- Clinic for Plastic and Hand Surgery, Burn Care Center, University of Witten/Herdecke, Cologne Merheim Medical Center (CMMC), Cologne, Germany
| | - R Lefering
- Institute for Research in Operative Medicine (IFOM), Faculty of Health, Witten/Herdecke University, Cologne, Germany
| | - C Opländer
- Institute for Research in Operative Medicine (IFOM), Faculty of Health, Witten/Herdecke University, Cologne, Germany
| | - J L Schiefer
- Clinic for Plastic and Hand Surgery, Burn Care Center, University of Witten/Herdecke, Cologne Merheim Medical Center (CMMC), Cologne, Germany
| |
Collapse
|
4
|
Hara Y, Shibata T. Characteristics of dermal vascularity in melasma and solar lentigo. PHOTODERMATOLOGY, PHOTOIMMUNOLOGY & PHOTOMEDICINE 2024; 40:e12953. [PMID: 38353352 DOI: 10.1111/phpp.12953] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 01/10/2024] [Accepted: 01/25/2024] [Indexed: 02/16/2024]
Abstract
BACKGROUND /PURPOSE Melasma and solar lentigo (SL) are major benign hyperpigmented lesions, and both have been shown to involve the dermal vasculature. This review discusses current knowledge regarding the clinical characteristics of dermal vascularity in melasma and SL, as well as the results of relevant molecular biological investigations. METHODS PubMed and Google Scholar were searched in December 2023 to identify articles related to melasma, SL, and the dermal vasculature in these lesions. RESULTS Vascular morphologies in melasma and SL have been detected by histological and non-invasive methods, including modalities such as optical coherence tomography. Biological studies have indicated that factors secreted from vascular endothelial cells, such as stem cell factor and endothelin-1, can promote melanogenesis. With respect to phototherapy, blood vessel-targeting laser treatments are expected to provide long-term suppression of pigmentation, but this regimen is only effective when dilated capillaries are visible. CONCLUSION In both melasma and SL, clinical and experimental investigations are revealing the contributions of dermal vascularity to hyperpigmentation. More effective treatment may require identification of hyperpigmentation subtypes. In the future, knowledge of treatment (including phototherapy) is expected to accumulate through reliable and validated non-invasive measurements.
Collapse
Affiliation(s)
- Yusuke Hara
- MIRAI Technology Institute, Shiseido Co., Ltd., Yokohama, Japan
| | - Takako Shibata
- MIRAI Technology Institute, Shiseido Co., Ltd., Yokohama, Japan
| |
Collapse
|
5
|
Hao S, Xiong Y, Guo S, Gao J, Chen X, Zhang R, Liu L, Wang J. Development and performance validation of a low-cost algorithms-based hyperspectral imaging system for radiodermatitis assessment. BIOMEDICAL OPTICS EXPRESS 2023; 14:4990-5004. [PMID: 37791251 PMCID: PMC10545207 DOI: 10.1364/boe.500067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 08/11/2023] [Accepted: 08/11/2023] [Indexed: 10/05/2023]
Abstract
Whilst radiotherapy (RT) is widely used for cancer treatment, radiodermatitis caused by RT is one most common severe side effect affecting 95% cancer patients. Accurate radiodermatitis assessment and classification is essential to adopt timely treatment, management and monitoring, which all depend on reliable and objective tools for radiodermatitis grading. We therefore, in this work, reported the development and grading performance validation of a low-cost (∼2318.2 CNY) algorithms-based hyperspectral imaging (aHSI) system for radiodermatitis assessment. The low-cost aHSI system was enabled through Monte Carlo (MC) simulations conducted on multi-spectra acquired from a custom built low-cost multispectral imaging (MSI) system, deriving algorithms-based hyper-spectra with spectral resolution of 1 nm. The MSI system was based on sequentially illuminated narrow-band light-emitting diodes (LEDs) and a CMOS camera. Erythema induced artificially on healthy volunteers was measured by the aHSI system developed, with algorithms-based hyper-spectra and skin layer resolved physiological parameters (i.e., the blood volume fraction (BVF) and the oxygen saturation of hemoglobin in blood, et. al.) derivation using MC simulations. The MC simulations derived BVF and the oxygen saturation of hemoglobin in blood showed significant (P < 0.001, analysis of variance: ANOVA) increase with erythema. Further 1D-convolution neural network (CNN) implemented on the algorithms-based hyper-spectra leads to an overall classification accuracy of 93.1%, suggesting the great potential of low-cost aHSI system developed for radiodermatitis assessment.
Collapse
Affiliation(s)
- Shicheng Hao
- Key Laboratory of Photoelectronic Imaging Technology and System of Ministry of Education of China, School of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China
| | - Ying Xiong
- Key Laboratory of Photoelectronic Imaging Technology and System of Ministry of Education of China, School of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China
| | - Sisi Guo
- Key Laboratory of Photoelectronic Imaging Technology and System of Ministry of Education of China, School of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China
| | - Jing Gao
- Key Laboratory of Photoelectronic Imaging Technology and System of Ministry of Education of China, School of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China
| | - Xiaotong Chen
- School of Medical Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Ruoyu Zhang
- School of Medical Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Lihui Liu
- Key Laboratory of Photoelectronic Imaging Technology and System of Ministry of Education of China, School of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China
| | - Jianfeng Wang
- Key Laboratory of Photoelectronic Imaging Technology and System of Ministry of Education of China, School of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China
| |
Collapse
|
6
|
Lee SF, Shariati S, Caini S, Wong H, Chan AW, Gojsevic M, Ogita M, Ye JC, Chia D, Chao M, Sung K, Kennedy SKF, Rajeswaran T, van den Hurk C, Wolf JR, Chan RJ, Behroozian T, Bonomo P, Chow E. StrataXRT for the prevention of acute radiation dermatitis in breast cancer: a systematic review and meta-analysis of randomized controlled trials. Support Care Cancer 2023; 31:515. [PMID: 37556002 DOI: 10.1007/s00520-023-07983-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Accepted: 08/01/2023] [Indexed: 08/10/2023]
Abstract
PURPOSE To evaluate the overall efficacy of StrataXRT, a topical gel dressing, in preventing acute radiation dermatitis (RD) in breast cancer patients undergoing radiotherapy (RT). METHODS A systematic search was conducted on April 25, 2023 in Ovid MEDLINE, Embase, and Cochrane Central Register of Controlled Trials. Randomized controlled trials (RCTs) assessing the effectiveness of StrataXRT in preventing acute RD in breast cancer patients undergoing adjuvant RT to the breast or chest wall with or without regional nodes were included. Pooled incidence odds ratio (OR) and 95% confidence interval (CI) were calculated using a random-effects model, with analysis and forest plots generated in RevMan v5.4. RESULTS The analysis included three RCTs with a total of 189 patients assessed using per-protocol analysis. Two RCTs compared StrataXRT to standard of care, while the third compared it with Mepitel film and was reported separately. In the former RCTs, the odds ratio (OR) for developing acute grade 3 RD favored StrataXRT at 0.05 (95% CI, 0.01-0.22; P < 0.0001). The OR for developing acute grades 2-3 RD was 0.32 (95% CI, 0.03-3.18; P = 0.33). The RCT comparing StrataXRT with Mepitel film showed insignificant ORs for grade 3 and grades 2-3 RD. One RCT reported significantly lower erythema index (P = 0.008) and melanin index (P = 0.015) in StrataXRT patients. The use of StrataXRT did not raise additional safety concerns. CONCLUSION StrataXRT may help prevent severe acute RD in breast cancer RT patients. Further high quality, large-scale studies are needed to confirm these findings.
Collapse
Affiliation(s)
- Shing Fung Lee
- Department of Radiation Oncology, National University Cancer Institute, National University Hospital, Singapore, Singapore.
- Department of Clinical Oncology, Tuen Mun Hospital, New Territories West Cluster, Hospital Authority, Hong Kong, Hong Kong.
| | - Saba Shariati
- Odette Cancer Centre, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Saverio Caini
- Cancer Risk Factors and Lifestyle Epidemiology Unit, Institute for Cancer Research, Prevention and Clinical Network (ISPO), Florence, Italy
| | - Henry Wong
- Department of Oncology, Princess Margaret Hospital, Hospital Authority, Hong Kong, Hong Kong
| | - Adrian W Chan
- Department of Clinical Oncology, Tuen Mun Hospital, New Territories West Cluster, Hospital Authority, Hong Kong, Hong Kong
| | - Milena Gojsevic
- Odette Cancer Centre, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Mami Ogita
- Department of Radiology, The University of Tokyo Hospital, Tokyo, Japan
| | - Jason C Ye
- Department of Radiation Oncology, University of Southern California Keck School of Medicine, Los Angeles, CA, USA
| | - David Chia
- Department of Radiation Oncology, National University Cancer Institute, National University Hospital, Singapore, Singapore
| | - Michael Chao
- Genesis Care Victoria, Ringwood Private Hospital, Ringwood East, Victoria, Australia
| | - KiHoon Sung
- Department of Radiation Oncology, Gachon University Gil Medical Center, Gachon University School of Medicine, Incheon, Republic of Korea
| | - Samantha K F Kennedy
- Odette Cancer Centre, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Thenugaa Rajeswaran
- Odette Cancer Centre, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Corina van den Hurk
- Research and Development Department, Netherlands Comprehensive Cancer Organisation, Utrecht, The Netherlands
| | - Julie Ryan Wolf
- Departments of Dermatology and Radiation Oncology, University of Rochester Medical Center, Rochester, NY, USA
| | - Raymond J Chan
- Caring Futures Institute, College of Nursing and Health Sciences, Flinders University, Bedford Park, Australia
| | - Tara Behroozian
- Michael G. DeGroote School of Medicine, McMaster University, Hamilton, ON, Canada
| | - Pierluigi Bonomo
- Radiation Oncology, Azienda Ospedaliero-Universitaria Careggi, University of Florence, Florence, Italy
| | - Edward Chow
- Odette Cancer Centre, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
7
|
Wormser GP, McKenna D, Morgan T, Scavarda C, Cooper D, Visintainer P. A Prospective Study to Characterize Symptoms and Symptom Severity in Adult Patients with Extracutaneous Manifestations of Lyme Disease: Extracutaneous Lyme Disease. Am J Med 2023:S0002-9343(23)00241-3. [PMID: 37062457 DOI: 10.1016/j.amjmed.2023.04.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 03/01/2023] [Accepted: 04/05/2023] [Indexed: 04/18/2023]
Abstract
BACKGROUND Systematic assessments of the presence and severity of particular symptoms over time are relatively uncommon for Lyme disease patients in the United States, and especially for Lyme disease patients with extracutaneous manifestations (ECLD). METHODS Symptoms and symptom severity of 12 particular symptoms were evaluated in a prospective study at baseline and at 12 months for 35 adult Lyme disease patients with ECLD, 91.4% of whom were already started on antibiotic therapy, and compared with 52 adult Lyme disease patients with erythema migrans, who were untreated at study entry. RESULTS No significant difference in the frequency of having at least 1 symptom out of the 12 evaluated was found between the 2 groups at either the baseline visit or the 12 month evaluation. Demographic variables were also similar between the 2 study groups, except that the ECLD patients were significantly less likely to be Caucasian, 24/35 (68.6%) of the ECLD cases vs 48/52 (92.3%) of the erythema migrans cases, p=0.008. CONCLUSION Lyme disease patients with ECLD had a similar frequency of symptoms at baseline compared to patients with erythema migrans . ECLD subjects, however, were significantly less like to be Caucasian raising the question of whether a preceding erythema migrans skin lesion may have been missed in persons with a darker skin color. An important limitation of our study, however, is that we did not record skin color per se, which should be considered for future studies.
Collapse
Affiliation(s)
- Gary P Wormser
- Division of Infectious Diseases, New York Medical College, Valhalla, NY 10595.
| | - Donna McKenna
- Division of Infectious Diseases, New York Medical College, Valhalla, NY 10595
| | - Tyler Morgan
- Division of Infectious Diseases, New York Medical College, Valhalla, NY 10595
| | - Carol Scavarda
- Division of Infectious Diseases, New York Medical College, Valhalla, NY 10595
| | - Denise Cooper
- Division of Infectious Diseases, New York Medical College, Valhalla, NY 10595
| | | |
Collapse
|
8
|
de Dormael R, Gueniche A, Bastien P, Verschoore M. Combining the use of two non-invasive instruments to confirm that a formula can improve skin luminance while respecting constitutive melanogenesis. J Cosmet Dermatol 2022; 21:6021-6026. [PMID: 35569124 DOI: 10.1111/jocd.15086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Revised: 04/26/2022] [Accepted: 05/10/2022] [Indexed: 12/27/2022]
Abstract
INTRODUCTION Skin radiance products achieve perceivable benefits with different sort of mechanism of action. AIMS To use two non-invasive instrumental devices to evaluate the effectiveness of a cosmetic formula designed to improve skin reflectance while respecting skin integrity. PATIENTS AND METHODS Subjects (N = 43) aged 18-50 years old had healthy skin of phototype V-VI and Individual Typology Angle between -10° and -50°. The treatment was applied twice weekly for 4 weeks on a delineated area of the back, and an adjacent area was left untreated. Instrumental and clinical scoring assessments of treated and untreated skin were performed at baseline and Day 26. RESULTS Between baseline and Day 26, reflectance (Delta L*) increased by 1.27 points and was considered as clinically relevant. Dermatologist clinical scoring of radiance significantly improved from 2.6 to 3.6 after 4 weeks of treatment and the Skin Color Chart Clarity level significantly decreased from a score of 15.5 to 14.3, representing a skin reflectance improvement. Conversely, the change between baseline and Day 26 in Mexameter Melanin Density was not clinically different for treated skin versus untreated skin (difference of 2.54). At Day 26, changes from baseline for Mexameter Melanin Density and Delta L* parameters appeared to be uncorrelated (r = -0.036). CONCLUSIONS This combination of two non-invasive devices can be useful to confirm that a product can modulate skin reflectance without modifying constitutive pigmentation. The formula tested in this study did not interfere with constitutive melanogenesis.
Collapse
|
9
|
Investigating the clinical implication of corneometer and mexameter readings towards objective, efficient evaluation of psoriasis vulgaris severity. Sci Rep 2022; 12:7469. [PMID: 35523995 PMCID: PMC9076632 DOI: 10.1038/s41598-022-11573-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Accepted: 04/25/2022] [Indexed: 11/08/2022] Open
Abstract
In clinical settings, although Psoriasis Area and Severity Index (PASI) scoring system can provide a quick visual assessment of the severity of psoriasis vulgaris, there is still a strong demand for higher efficiency and accuracy in quantifying the inflammation status of psoriatic lesions. Currently, there are already commercial systems, such as the Courage + Khazaka Corneometer and Mexameter that measure skin capacitance and optical reflectance, for conveniently quantifying the status of skin barrier function and erythema of skin. Despite numerous comparisons of the Courage + Khazaka system with the PASI scoring system, they are rarely compared on parity with diffuse reflectance spectroscopy (DRS) based systems. In this study, we employed a custom-built DRS system shown to be able to determine the skin water-protein binding status and the hemoglobin concentration, and we performed cross-validation of the DRS measurement results with the readings derived from the Corneometer and Mexameter as well as a portion of the PASI scores. Our results revealed that the erythema readings from the Mexameter were a good representation of skin oxygenated hemoglobin but not the deoxygenated hemoglobin. On the other hand, the dermatologists recruited in this study were inclined to rate higher scores on the “erythema” category as skin’s deoxygenated hemoglobin level was higher. Thus, the Mexameter derived erythema readings may not be coherent with the PASI erythema scores. Further, the Corneometer derived skin capacitance readings were well correlated to the PASI “desquamation” and “thickness” scores, while the PASI “desquamation” evaluation was a dominating factor contributing to the DRS deduced water-protein binding status. We conclude that the DRS method could be a valuable addition to existing skin capacitance/reflectance measurement systems and the PASI scoring system toward achieving a more efficient and objective clinical psoriasis vulgaris severity evaluation.
Collapse
|
10
|
Langeveld M, van de Lande LS, O' Sullivan E, van der Lei B, van Dongen JA. Skin measurement devices to assess skin quality: A systematic review on reliability and validity. Skin Res Technol 2021; 28:212-224. [PMID: 34751474 PMCID: PMC9299221 DOI: 10.1111/srt.13113] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Accepted: 09/25/2021] [Indexed: 11/30/2022]
Abstract
Background Many treatments aim to slow down or reverse the visible signs of skin aging and thereby improve skin quality. Measurement devices are frequently employed to measure the effects of these treatments to improve skin quality, for example, skin elasticity, color, and texture. However, it remains unknown which of these devices is most reliable and valid. Materials and methods MEDLINE, Embase, Cochrane Central, Web of Science, and Google Scholar databases were searched. Instruments were scored on reporting construct validity by means of convergent validity, interobserver, intraobserver, and interinstrument reliability. Results For the evaluation of skin color, 11 studies were included describing 16 measurement devices, analyzing 3172 subjects. The most reliable device for skin color assessment is the Minolta Chromameter CR‐300 due to good interobserver, intraobserver, and interinstrument reliability. For skin elasticity, seven studies assessed nine types of devices analyzing 290 subjects in total. No intra and interobserver reliability was reported. Skin texture was assessed in two studies evaluating 72 subjects using three different types of measurement devices. The PRIMOS device reported excellent intra and interobserver reliability. None of the included reviewed devices could be determined to be valid based on construct validity. Conclusion The most reliable devices to evaluate skin color and texture in ordinary skin were, respectively, the Minolta Chromameter and PRIMOS. No reliable device is available to measure skin elasticity in ordinary skin and none of the included devices could be determined to be designated as valid.
Collapse
Affiliation(s)
- Mirte Langeveld
- Medical Faculty, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Lara S van de Lande
- Craniofacial Unit Great Ormond Street Hospital for Children and UCL Great Ormond Street Institute of Child Health, London, UK
| | - Eimear O' Sullivan
- Craniofacial Unit Great Ormond Street Hospital for Children and UCL Great Ormond Street Institute of Child Health, London, UK
| | - Berend van der Lei
- Department of Plastic Surgery, University of Groningen and University Medical Center Groningen, Groningen, the Netherlands
| | - Joris A van Dongen
- Department of Plastic Surgery, University Medical Center Utrecht, Utrecht, the Netherlands
| |
Collapse
|
11
|
Galeb HA, Wilkinson EL, Stowell AF, Lin H, Murphy ST, Martin‐Hirsch PL, Mort RL, Taylor AM, Hardy JG. Melanins as Sustainable Resources for Advanced Biotechnological Applications. GLOBAL CHALLENGES (HOBOKEN, NJ) 2021; 5:2000102. [PMID: 33552556 PMCID: PMC7857133 DOI: 10.1002/gch2.202000102] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Revised: 11/04/2020] [Indexed: 05/17/2023]
Abstract
Melanins are a class of biopolymers that are widespread in nature and have diverse origins, chemical compositions, and functions. Their chemical, electrical, optical, and paramagnetic properties offer opportunities for applications in materials science, particularly for medical and technical uses. This review focuses on the application of analytical techniques to study melanins in multidisciplinary contexts with a view to their use as sustainable resources for advanced biotechnological applications, and how these may facilitate the achievement of the United Nations Sustainable Development Goals.
Collapse
Affiliation(s)
- Hanaa A. Galeb
- Department of ChemistryLancaster UniversityLancasterLA1 4YBUK
- Department of ChemistryScience and Arts CollegeRabigh CampusKing Abdulaziz UniversityJeddah21577Saudi Arabia
| | - Emma L. Wilkinson
- Department of Biomedical and Life SciencesLancaster UniversityLancasterLA1 4YGUK
| | - Alison F. Stowell
- Department of Organisation, Work and TechnologyLancaster University Management SchoolLancaster UniversityLancasterLA1 4YXUK
| | - Hungyen Lin
- Department of EngineeringLancaster UniversityLancasterLA1 4YWUK
| | - Samuel T. Murphy
- Department of EngineeringLancaster UniversityLancasterLA1 4YWUK
- Materials Science InstituteLancaster UniversityLancasterLA1 4YBUK
| | - Pierre L. Martin‐Hirsch
- Lancashire Teaching Hospitals NHS TrustRoyal Preston HospitalSharoe Green LanePrestonPR2 9HTUK
| | - Richard L. Mort
- Department of Biomedical and Life SciencesLancaster UniversityLancasterLA1 4YGUK
| | - Adam M. Taylor
- Lancaster Medical SchoolLancaster UniversityLancasterLA1 4YWUK
| | - John G. Hardy
- Department of ChemistryLancaster UniversityLancasterLA1 4YBUK
- Materials Science InstituteLancaster UniversityLancasterLA1 4YBUK
| |
Collapse
|
12
|
Nadimi ES, Majtner T, Yderstraede KB, Blanes-Vidal V. Facial erythema detects diabetic neuropathy using the fusion of machine learning, random matrix theory and self organized criticality. Sci Rep 2020; 10:16785. [PMID: 33033383 PMCID: PMC7546636 DOI: 10.1038/s41598-020-73744-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Accepted: 09/21/2020] [Indexed: 11/09/2022] Open
Abstract
Rubeosis faciei diabeticorum, caused by microangiopathy and characterized by a chronic facial erythema, is associated with diabetic neuropathy. In clinical practice, facial erythema of patients with diabetes is evaluated based on subjective observations of visible redness, which often goes unnoticed leading to microangiopathic complications. To address this major shortcoming, we designed a contactless, non-invasive diagnostic point-of-care-device (POCD) consisting of a digital camera and a screen. Our solution relies on (1) recording videos of subject's face (2) applying Eulerian video magnification to videos to reveal important subtle color changes in subject's skin that fall outside human visual limits (3) obtaining spatio-temporal tensor expression profile of these variations (4) studying empirical spectral density (ESD) function of the largest eigenvalues of the tensors using random matrix theory (5) quantifying ESD functions by modeling the tails and decay rates using power law in systems exhibiting self-organized-criticality and (6) designing an optimal ensemble of learners to classify subjects into those with diabetic neuropathy and those of a control group. By analyzing a short video, we obtained a sensitivity of 100% in detecting subjects diagnosed with diabetic neuropathy. Our POCD paves the way towards the development of an inexpensive home-based solution for early detection of diabetic neuropathy and its associated complications.
Collapse
Affiliation(s)
- Esmaeil S Nadimi
- Applied AI and Data Science (AID), Maersk Mc-Kinney Moller Institute, University of Southern Denmark, 5230, Odense, Denmark.
| | - Tomas Majtner
- Applied AI and Data Science (AID), Maersk Mc-Kinney Moller Institute, University of Southern Denmark, 5230, Odense, Denmark
| | - Knud B Yderstraede
- Steno Diabetes Center Odense, Odense University Hospital, 5230, Odense, Denmark
| | - Victoria Blanes-Vidal
- Applied AI and Data Science (AID), Maersk Mc-Kinney Moller Institute, University of Southern Denmark, 5230, Odense, Denmark
| |
Collapse
|
13
|
Ahn S, Sung K, Kim HJ, Choi YE, Lee YK, Kim JS, Lee SK, Roh JY. Reducing Radiation Dermatitis Using a Film-forming Silicone Gel During Breast Radiotherapy: A Pilot Randomized-controlled Trial. In Vivo 2020; 34:413-422. [PMID: 31882508 DOI: 10.21873/invivo.11790] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2019] [Revised: 10/09/2019] [Accepted: 10/10/2019] [Indexed: 11/10/2022]
Abstract
BACKGROUND/AIM To evaluate whether topical use of a film-forming silicone gel (StrataXRT®) could reduce radiation dermatitis compared to a moisturizing cream (X-derm®) in patients receiving whole breast radiotherapy. PATIENTS AND METHODS A total of 56 patients with breast cancer were randomized to use StrataXRT or X-derm. The severity of radiation dermatitis was graded using physiological skin parameters, clinician-assessed visual rating scales and patient-reported symptoms. Changes in these parameters from baseline to 4 weeks post-radiotherapy were evaluated every two weeks. RESULTS Two-way repeated-measures ANOVA revealed different patterns of changes in the erythema index (F=3.609, p=0.008) and melanin index (F=3.475, p=0.015). The post hoc analysis demonstrated a significantly lower erythema index and melanin index in the patients allocated to the StrataXRT group. CONCLUSION The use of StrataXRT can reduce radiation dermatitis with respect to objectively measured physiological skin parameters. The results of the present study will support the feasibility of conducting a larger randomized controlled trial.
Collapse
Affiliation(s)
- Songmi Ahn
- Department of Radiation Oncology, Gachon University Gil Medical Center, Gachon University School of Medicine, Incheon, Republic of Korea
| | - Kihoon Sung
- Department of Radiation Oncology, Gachon University Gil Medical Center, Gachon University School of Medicine, Incheon, Republic of Korea
| | - Hyun Ju Kim
- Department of Radiation Oncology, Gachon University Gil Medical Center, Gachon University School of Medicine, Incheon, Republic of Korea
| | - Young Eun Choi
- Department of Radiation Oncology, Gachon University Gil Medical Center, Gachon University School of Medicine, Incheon, Republic of Korea
| | - Young Kyu Lee
- Department of Radiation Oncology, Gachon University Gil Medical Center, Gachon University School of Medicine, Incheon, Republic of Korea
| | - Jeong Soo Kim
- Department of Dermatology, Gachon University Gil Medical Center, Gachon University School of Medicine, Incheon, Republic of Korea
| | - Seul Ki Lee
- Department of Dermatology, Gachon University Gil Medical Center, Gachon University School of Medicine, Incheon, Republic of Korea
| | - Joo-Young Roh
- Department of Dermatology, Gachon University Gil Medical Center, Gachon University School of Medicine, Incheon, Republic of Korea
| |
Collapse
|
14
|
Kanellis VG. A review of melanin sensor devices. Biophys Rev 2019; 11:843-849. [PMID: 31396804 PMCID: PMC6874939 DOI: 10.1007/s12551-019-00581-8] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2019] [Accepted: 07/31/2019] [Indexed: 02/01/2023] Open
Abstract
Knowing how readily the skin produces melanin is invaluable in reducing photochemical and phototherapy overtreatment in dermatology and also in reducing the risk of actinic skin damage and skin cancer from excessive radiant light exposure. The commonly used Fitzpatrick skin type (FST) classification scale is often used to subjectively assess ultraviolet light sensitivity and susceptibility to sunburn following significant sunlight exposure. However, the FST scale falls short in the assessment of nonwhite skin types. Alternatively, commercially available melanin sensor devices, called melanometers, can be used to objectively quantify useful skin parameters such as the epidermal melanin concentration (EMC). This study reviews commercially available melanometers and their use in quantifying epidermal melanin concentration (EMC) and the individual maximum safe radiant exposure (IMSRE) for an individual in clinical, workplace and community settings.
Collapse
|
15
|
Wright CY, Lucas RM, Kapwata T, Kunene Z, du Plessis JL. Towards a reliable, non-invasive melanin assessment for pigmented skin. Skin Res Technol 2018; 25:100-102. [PMID: 29790599 DOI: 10.1111/srt.12592] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/28/2018] [Indexed: 11/30/2022]
Affiliation(s)
- C Y Wright
- Environment and Health Research Unit, South African Medical Research Council, Pretoria, South Africa.,Department of Geography, Geoinformatics and Meteorology, University of Pretoria, Pretoria, South Africa
| | - R M Lucas
- Research School of Population Health, National Centre for Epidemiology and Population Health, Australian National University, Canberra, Australia.,Centre for Ophthalmology and Visual Sciences, University of Western Australia, Perth, Australia
| | - T Kapwata
- Environment and Health Research Unit, South African Medical Research Council, Johannesburg, South Africa
| | - Z Kunene
- Environment and Health Research Unit, South African Medical Research Council, Johannesburg, South Africa
| | - J L du Plessis
- Occupational Hygiene and Health Research Initiative, North-West University, Potchefstroom, South Africa
| |
Collapse
|
16
|
Boyce ST, Lloyd CM, Kleiner MC, Swope VB, Abdel-Malek Z, Supp DM. Restoration of cutaneous pigmentation by transplantation to mice of isogeneic human melanocytes in dermal-epidermal engineered skin substitutes. Pigment Cell Melanoma Res 2017. [PMID: 28640957 DOI: 10.1111/pcmr.12609] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Autologous engineered skin substitutes (ESS) containing melanocytes (hM) may restore pigmentation and photoprotection after grafting to full-thickness skin wounds. In this study, normal hM were isolated from discard skin, propagated with or without tyrosinase inhibitors, cryopreserved, recovered into culture, and added to ESS (ESS-P) before transplantation. ESS-P were incubated in either UCMC160/161 or UCDM1 medium, scored for hM densities, and grafted to mice. The results showed that sufficient hM can be propagated to expand donor tissue by 100-fold; incubation of hM in tyrosinase inhibitors reduced pigment levels but did not change hM recovery after cryopreservation; hM densities in ESS-P were greater after incubation in UCDM1 than UCMC160 medium; hM were localized to the dermal-epidermal junction of ESS-P; and UCDM1 medium promoted earlier pigment distribution and density. These results indicate that hM can be incorporated into ESS-P efficiently to restore cutaneous pigmentation and UV photoprotection after full-thickness skin loss conditions.
Collapse
Affiliation(s)
- Steven T Boyce
- Department of Surgery, University of Cincinnati, Cincinnati, OH, USA.,Research Department, Shriners Hospitals for Children, Cincinnati, OH, USA
| | - Christopher M Lloyd
- Department of Surgery, University of Cincinnati, Cincinnati, OH, USA.,Research Department, Shriners Hospitals for Children, Cincinnati, OH, USA
| | - Mark C Kleiner
- Department of Surgery, University of Cincinnati, Cincinnati, OH, USA.,Research Department, Shriners Hospitals for Children, Cincinnati, OH, USA
| | - Viki B Swope
- Department of Dermatology, University of Cincinnati, Cincinnati, OH, USA
| | - Zalfa Abdel-Malek
- Department of Dermatology, University of Cincinnati, Cincinnati, OH, USA
| | - Dorothy M Supp
- Department of Surgery, University of Cincinnati, Cincinnati, OH, USA.,Research Department, Shriners Hospitals for Children, Cincinnati, OH, USA
| |
Collapse
|
17
|
Cho M, Lee DH, Doh EJ, Kim Y, Chung JH, Kim HC, Kim S. Development and clinical validation of a novel photography-based skin erythema evaluation system: a comparison with the calculated consensus of dermatologists. Int J Cosmet Sci 2017; 39:426-434. [DOI: 10.1111/ics.12393] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2016] [Accepted: 02/04/2017] [Indexed: 12/30/2022]
Affiliation(s)
- M. Cho
- Interdisciplinary Program for Bioengineering; Graduate School; Seoul National University; Seoul 110-744 Korea
| | - D.-H. Lee
- Department of Dermatology; Seoul National University Hospital; Seoul 110-744 Korea
| | - E. J. Doh
- Department of Dermatology; Seoul National University Hospital; Seoul 110-744 Korea
| | - Y. Kim
- Department of Biomedical Engineering; Seoul National University Hospital; Seoul 110-744 Korea
| | - J. H. Chung
- Department of Dermatology; Seoul National University Hospital; Seoul 110-744 Korea
| | - H. C. Kim
- Department of Biomedical Engineering; Seoul National University College of Medicine; Seoul 110-799 Korea
- Institute of Medical and Biological Engineering; Seoul National University; Seoul 151-742 Korea
| | - S. Kim
- Department of Biomedical Engineering; Seoul National University College of Medicine; Seoul 110-799 Korea
- Institute of Medical and Biological Engineering; Seoul National University; Seoul 151-742 Korea
| |
Collapse
|