Oliveira IV, Oliveira LVSX, Santos VMB, Souza JLT, Costa MLL, Borges PF, Campos DB, Talieri IC. Determination of intraocular pressure and Schirmer tear test and the comparison between the applanation tonometer (Tono-Pen AVIA®) and the rebound tonometer (TonoVet Plus®) in mini lionhead rabbits. Vet Ophthalmol 2024; 27:53-60. [PMID: 37747053 DOI: 10.1111/vop.13150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 09/13/2023] [Accepted: 09/13/2023] [Indexed: 09/26/2023]
Abstract
OBJECTIVE To determine intraocular pressure (IOP) and tear production, as well as to compare the IOP obtained with the TonoVet Plus® (rebound) with the Tono-Pen Avia® (applanation) tonometers. ANIMALS Twenty-five Mini Lionhead rabbits (n = 50 eyes). PROCEDURE Tear production was measured at 6:00 a.m. and 6:00 p.m. by using the STT. The IOP reading was performed with the rebound tonometer, followed by the applanation tonometer, at 6:00 a.m., 9:00 a.m., 12:00 p.m., 3:00 p.m., and 6:00 p.m. Regression analysis, analysis of variance (anova) and Bland-Altman statistics were used. RESULTS Daily tear production was 10.25 ± 3.75 mm/min, with no differences among the moments evaluated. Average daily IOP was 17.7 ± 3.08 mmHg with the TonoVet Plus® and 11.5 ± 4.56 mmHg with the Tono-Pen Avia®. IOP values were higher at the beginning and end of the day with both tonometers. CONCLUSION The IOP values are higher with the TonoVet Plus® tonometer. The reference values of IOP and tear production obtained in this work may support the diagnosis, treatment, and monitoring of ocular disorders in pet Mini Lionhead rabbits.
Collapse
Affiliation(s)
- Ismael V Oliveira
- Graduate Program in Animal Science, Agricultural Science Center, Federal University of Paraíba (UFPB), Areia, Brazil
| | - Lídia V S X Oliveira
- Graduate Program in Animal Science, Agricultural Science Center, Federal University of Paraíba (UFPB), Areia, Brazil
| | - Victória M B Santos
- Department of Veterinary Sciences, Agricultural Science Center, Federal University of Paraíba (UFPB), Areia, Brazil
| | - João L T Souza
- Department of Veterinary Sciences, Agricultural Science Center, Federal University of Paraíba (UFPB), Areia, Brazil
| | - Maria Lindomárcia L Costa
- Department of Animal Science, Agricultural Science Center, Federal University of Paraíba (UFPB), Areia, Brazil
| | - Péricles F Borges
- Department of Social Sciences, Agricultural Science Center, Federal University of Paraíba (UFPB), Areia, Brazil
| | - Danila B Campos
- Graduate Program in Animal Science, Agricultural Science Center, Federal University of Paraíba (UFPB), Areia, Brazil
- Department of Veterinary Sciences, Agricultural Science Center, Federal University of Paraíba (UFPB), Areia, Brazil
| | - Ivia C Talieri
- Department of Veterinary Sciences, Agricultural Science Center, Federal University of Paraíba (UFPB), Areia, Brazil
| |
Collapse
|
2
|
Almeida VTDS, Garcia CB, Jorge AT, Paulino Júnior D, Martins JG, Pereira PM, Almeida Júnior SD, Dias FGG. Comparison between the rebound (TD - 8000 portable) and applanation tonometer (Tono-Pen AviaTM) managed by different evaluators for intraocular pressure measurements in rabbits. CIÊNCIA ANIMAL BRASILEIRA 2022. [DOI: 10.1590/1809-6891v23e-73055e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Abstract This study aimed to compare values of intraocular pressure (IOP) by different tonometers and evaluators (veterinary ophthalmologist specialist and veterinary not a specialist). For this, 30 rabbits were used, and in all (n = 60 eyes), the IOP was initially measured with a rebound tonometer (model TD - 8000 portable, Apramed Indústria e Comércio de Equipamentos Médicos Ltda) and, subsequently, with an applanation tonometer (portable model Tono-Pen AviaTM®, Reichert Technologies®, USA). With the two devices, the measurements in mmHg were performed in the central region of the corneas, always performed in the same period, by a professional veterinary ophthalmologist (specialist) and a professional veterinary (not a specialist). Data were statistically compared using the simple analysis of variance test. With the rebound tonometer, IOP ranged from 7 to 14 mmHg when measured by both evaluators; while with the applanation tonometer, from 9 to 15 mmHg by the specialist and from 8 to 16 mmHg by the non-specialist. In the right eyes, the IOP measured by the applanation tonometer by the non-experienced evaluator was statistically lower than the specialist's values; yet, the results of the two evaluators were higher in these same eyes when compared with those of the rebound tonometer. In the left eyes, the IOP measured by the applanation tonometer by the non-experienced evaluator was statistically higher than the specialist's values with the rebound tonometer. Thus, it was possible to infer that, regardless of experience in the area, the applanation tonometer indicated higher mean values of IOP in both eyes and, about the evaluators, the means of the measurements performed by the specialist were higher compared to the non-professional specialist.
Collapse
|
3
|
Almeida VTDS, Garcia CB, Jorge AT, Paulino Júnior D, Martins JG, Pereira PM, Almeida Júnior SD, Dias FGG. Comparação entre o tonômetro de rebote (TD - 8000 portable) e aplanação (Tono-Pen AviaTM) manuseados por diferentes avaliadores para mensurações da pressão intraocular em coelhos. CIÊNCIA ANIMAL BRASILEIRA 2022. [DOI: 10.1590/1809-6891v23e-73055p] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Resumo Este estudo teve como objetivo comparar os valores da pressão intraocular (PIO) por diferentes tonômetros e avaliadores (veterinário oftalmologista especialista e veterinário não especialista). Para isso, foram utilizados 30 coelhos, em todos (n = 60 olhos), a PIO foi medida inicialmente com um tonômetro de rebote (model TD - 8000 portable, Apramed Indústria e Comércio de Equipamentos Médicos Ltda) e, posteriormente, com um tonômetro de aplanação (portable model Tono-Pen AviaTM®, Reichert Technologies®, USA). Com os dois aparelhos, as medidas em mmHg foram realizadas na região central das córneas, sempre no mesmo período, por um profissional oftalmologista veterinário (especialista) e um profissional veterinário (não especialista). Os dados foram comparados estatisticamente por meio do teste de análise de variância simples. Com o tonômetro de rebote, a PIO variou de 7 a 14 mmHg quando medida por ambos os avaliadores; enquanto com o tonômetro de aplanação, de 9 a 15 mmHg pelo especilista e de 8 a 16 mmHg pelo não especialista. Nos olhos direitos, a PIO medida pelo tonômetro de aplanação pelo avaliador não experiente foi estatisticamente inferior aos valores do especialista; ainda, os resultados dos dois avaliadores foram maiores nestes mesmos olhos quando comparados com os do tonômetro de rebote. Nos olhos esquerdos, a PIO medida pelo tonômetro de aplanação pelo avaliador não experiente foi estatisticamente superior aos valores do especialista com o tonômetro de rebote. Assim, foi possível inferir que, independente da experiência na área, o tonômetro de aplanação indicou maiores valores médios de PIO em ambos os olhos e, em relação aos avaliadores, as médias das medidas realizadas pelos especialistas foram maiores em relação ao não especialista.
Collapse
|
4
|
Bertens CJF, van Mechelen RJS, Berendschot TTJM, Gijs M, Wolters JEJ, Gorgels TGMF, Nuijts RMMA, Beckers HJM. Repeatability, reproducibility, and agreement of three tonometers for measuring intraocular pressure in rabbits. Sci Rep 2021; 11:19217. [PMID: 34584185 PMCID: PMC8478901 DOI: 10.1038/s41598-021-98762-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Accepted: 09/14/2021] [Indexed: 12/04/2022] Open
Abstract
The aim of this study was to evaluate repeatability, reproducibility, and agreement of three commonly used tonometers in animal research (TonoLab, TonoVet, and TonoPEN AVIA) in a cohort of 24 rabbits. Additionally, the impact of sedation on IOP was investigated in 21 New Zealand White rabbits with the TonoVet tonometer. Repeatability was determined using the coefficient of variation (CoV) for two observers. For the TonoLab (6.55%) and TonoVet (6.38%) the CoV was lower than for the TonoPEN AVIA (10.88%). The reproducibility was highest for the TonoVet (0.2 ± 3.3 mmHg), followed by the TonoLab (0 ± 12.89 mmHg) and lowest for the TonoPEN AVIA (− 1.48 ± 10.3 mmHg). The TonoLab and TonoVet showed the highest agreement (r = 0.85, R2 = 0.73). After sedation, a significant IOP reduction (often > 25%) was observed. Our results show that among the three tonometers tested, the TonoVet tonometer is best for use in rabbits while the TonoLab should be avoided. The impact of sedation on IOP was substantial and should be taken into account during experimentation.
Collapse
Affiliation(s)
- Christian J F Bertens
- Department of Ophthalmology, University Eye Clinic Maastricht, School for Mental Health and Neuroscience (MHeNs), Maastricht University Medical Center+ (MUMC+), P. Debyelaan 25, PO Box 5800, 6229 HX, Maastricht, The Netherlands. .,Chemelot Institute for Science and Technology (InSciTe), Gaetano Martinolaan 63-65, 6229 GS, Maastricht, The Netherlands.
| | - Ralph J S van Mechelen
- Department of Ophthalmology, University Eye Clinic Maastricht, School for Mental Health and Neuroscience (MHeNs), Maastricht University Medical Center+ (MUMC+), P. Debyelaan 25, PO Box 5800, 6229 HX, Maastricht, The Netherlands.,Chemelot Institute for Science and Technology (InSciTe), Gaetano Martinolaan 63-65, 6229 GS, Maastricht, The Netherlands
| | - Tos T J M Berendschot
- Department of Ophthalmology, University Eye Clinic Maastricht, School for Mental Health and Neuroscience (MHeNs), Maastricht University Medical Center+ (MUMC+), P. Debyelaan 25, PO Box 5800, 6229 HX, Maastricht, The Netherlands
| | - Marlies Gijs
- Department of Ophthalmology, University Eye Clinic Maastricht, School for Mental Health and Neuroscience (MHeNs), Maastricht University Medical Center+ (MUMC+), P. Debyelaan 25, PO Box 5800, 6229 HX, Maastricht, The Netherlands.,Chemelot Institute for Science and Technology (InSciTe), Gaetano Martinolaan 63-65, 6229 GS, Maastricht, The Netherlands
| | - Jarno E J Wolters
- Department of Ophthalmology, University Eye Clinic Maastricht, School for Mental Health and Neuroscience (MHeNs), Maastricht University Medical Center+ (MUMC+), P. Debyelaan 25, PO Box 5800, 6229 HX, Maastricht, The Netherlands.,Chemelot Institute for Science and Technology (InSciTe), Gaetano Martinolaan 63-65, 6229 GS, Maastricht, The Netherlands
| | - Theo G M F Gorgels
- Department of Ophthalmology, University Eye Clinic Maastricht, School for Mental Health and Neuroscience (MHeNs), Maastricht University Medical Center+ (MUMC+), P. Debyelaan 25, PO Box 5800, 6229 HX, Maastricht, The Netherlands.,Chemelot Institute for Science and Technology (InSciTe), Gaetano Martinolaan 63-65, 6229 GS, Maastricht, The Netherlands
| | - Rudy M M A Nuijts
- Department of Ophthalmology, University Eye Clinic Maastricht, School for Mental Health and Neuroscience (MHeNs), Maastricht University Medical Center+ (MUMC+), P. Debyelaan 25, PO Box 5800, 6229 HX, Maastricht, The Netherlands.,Chemelot Institute for Science and Technology (InSciTe), Gaetano Martinolaan 63-65, 6229 GS, Maastricht, The Netherlands
| | - Henny J M Beckers
- Department of Ophthalmology, University Eye Clinic Maastricht, School for Mental Health and Neuroscience (MHeNs), Maastricht University Medical Center+ (MUMC+), P. Debyelaan 25, PO Box 5800, 6229 HX, Maastricht, The Netherlands.,Chemelot Institute for Science and Technology (InSciTe), Gaetano Martinolaan 63-65, 6229 GS, Maastricht, The Netherlands
| |
Collapse
|
5
|
Lim J, Kang S, Park S, Park E, Nam T, Jeong S, Seo K. Intraocular Pressure Measurement by Rebound Tonometry (TonoVet) in Normal Pigeons ( Columba livia). J Avian Med Surg 2019; 33:46-52. [PMID: 31124611 DOI: 10.1647/2017-329] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
We evaluated the applicability of a rebound tonometer (TonoVet) in pigeon eyes and established normal reference intraocular pressure (IOP) values in healthy pigeons; 20 eyes of euthanized pigeons were used for calibration of the TonoVet and 48 eyes of 24 adult pigeons were used for measurement of reference IOP. First, IOP of pigeon eyes ex vivo were measured using the 'd' and the 'p' modes of the TonoVet and compared to manometric IOP values from 5 to 80 mm Hg. Then, to establish normal reference values, IOP was measured from clinically normal pigeons in vivo. The 'd' and the 'p' modes of the TonoVet showed a strong linear correlation with the manometric IOP (R2 = .996 and .991, respectively). The obtained regression formulas were: y1 = 0.439x + 2.059 and y2 = 0.330x - 0.673, respectively (y1, 'd' mode of TonoVet; y2, 'p' mode of TonoVet; x, manometric IOP). The 'd' and the 'p' modes consistently measured one-half and one-third of the actual IOP, respectively. Therefore, the formula obtained through the 'd' mode was applied to obtain reference values. The calibrated IOP of normal pigeon eyes was 19.5 ± 4.4 mm Hg. The actual IOP could be calculated using the presented formula. Considering the limitations of the 'p' mode, use of the 'd' mode is more appropriate. Therefore, the TonoVet rebound tonometry under the 'd' mode is a reliable method for measuring IOP in pigeons.
Collapse
Affiliation(s)
- Jaegook Lim
- From the Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Research Institute for Veterinary Science and BK 21 Creative Veterinary Research Center, Seoul National University, Gwanak-gu, Seoul, 08826, Korea
| | - Seonmi Kang
- From the Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Research Institute for Veterinary Science and BK 21 Creative Veterinary Research Center, Seoul National University, Gwanak-gu, Seoul, 08826, Korea
| | - Sangwan Park
- From the Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Research Institute for Veterinary Science and BK 21 Creative Veterinary Research Center, Seoul National University, Gwanak-gu, Seoul, 08826, Korea
| | - Eunjin Park
- From the Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Research Institute for Veterinary Science and BK 21 Creative Veterinary Research Center, Seoul National University, Gwanak-gu, Seoul, 08826, Korea
| | - Taekjin Nam
- From the Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Research Institute for Veterinary Science and BK 21 Creative Veterinary Research Center, Seoul National University, Gwanak-gu, Seoul, 08826, Korea
| | - Seowoo Jeong
- From the Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Research Institute for Veterinary Science and BK 21 Creative Veterinary Research Center, Seoul National University, Gwanak-gu, Seoul, 08826, Korea
| | - Kangmoon Seo
- From the Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Research Institute for Veterinary Science and BK 21 Creative Veterinary Research Center, Seoul National University, Gwanak-gu, Seoul, 08826, Korea
| |
Collapse
|
6
|
Jugant S, Robin MC, Regnier A, Cassard H, Herman N, Conchou F, Douet JY. Congenital lacrimal fistula in two prim'Holstein calves. Vet Ophthalmol 2019; 22:368-373. [PMID: 30715787 DOI: 10.1111/vop.12640] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2018] [Revised: 11/18/2018] [Accepted: 11/23/2018] [Indexed: 11/25/2022]
Abstract
Two 4- and 8-month-old prim'Holstein calves were presented for chronic epiphora. Examination of the affected eyes revealed an abnormal duct opening inferonasal to the medial canthus. A diagnosis of congenital lacrimal fistula was made based on conventional and computed tomographic-dacryocystography findings. These revealed an ectopic channel connecting the nasolacrimal duct to the skin opening near the medial canthus. Both of the calves were surgically treated with resection and closure of the ectopic duct and placement of a nasolacrimal stent.
Collapse
Affiliation(s)
- Sophie Jugant
- Département des Sciences Cliniques, Ecole Nationale Vétérinaire de Toulouse, Université Fédérale de Toulouse Midi-Pyrénées, Toulouse, France
| | - Marie-Claire Robin
- Département des Sciences Cliniques, Ecole Nationale Vétérinaire de Toulouse, Université Fédérale de Toulouse Midi-Pyrénées, Toulouse, France
| | - Alain Regnier
- Département des Sciences Cliniques, Ecole Nationale Vétérinaire de Toulouse, Université Fédérale de Toulouse Midi-Pyrénées, Toulouse, France
| | - Hervé Cassard
- Département Élevage et produits - Santé publique vétérinaire, Ecole Nationale Vétérinaire de Toulouse, Université Fédérale de Toulouse Midi-Pyrénées, Toulouse, France
| | - Nicolas Herman
- Département Élevage et produits - Santé publique vétérinaire, Ecole Nationale Vétérinaire de Toulouse, Université Fédérale de Toulouse Midi-Pyrénées, Toulouse, France
| | - Fabrice Conchou
- Département des Sciences Cliniques, Ecole Nationale Vétérinaire de Toulouse, Université Fédérale de Toulouse Midi-Pyrénées, Toulouse, France
| | - Jean-Yves Douet
- Département des Sciences Cliniques, Ecole Nationale Vétérinaire de Toulouse, Université Fédérale de Toulouse Midi-Pyrénées, Toulouse, France
| |
Collapse
|
7
|
Morais T, Neves C, Borges N, Lima A, Silva L, Castro L, Espindola S, Cunha P. Avaliação da produção lacrimal, pressão intraocular, retinografia e biometria ocular em bovinos das raças Nelore e Gir hígidos. ARQ BRAS MED VET ZOO 2019. [DOI: 10.1590/1678-4162-10263] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
RESUMO No presente estudo, foram avaliados parâmetros oftalmológicos de 38 bovinos das raças Nelore (n= 19; grupo GN) e Gir (n= 19; grupo GG), machos, com idade média de 15 meses. Os exames oftalmológicos realizados foram teste lacrimal de Schirmer 1 (TLS-1), tonometria de aplanação, retinografia e biometria por ultrassonografia em modo B. Os resultados do TLS-1, tonometria de aplanação e biometria ocular foram avaliados por meio da análise de variância (ANOVA), e as médias comparadas pelo teste de Tukey. Para o exame de retinografia, foi realizada a análise descritiva das estruturas anatômicas. O TLS-1 e a tonometria não diferiram (P≥0,05) nas comparações entre os olhos e entre os grupos raciais. A retinografia permitiu a visualização do disco óptico, dos vasos retinianos, do fundo tapetal e não tapetal, sem constatação de diferenças anatômicas entre as raças. Por meio da biometria ocular, foram observados valores maiores nos animais da raça Gir para as medidas do comprimento axial (CAx), da espessura da lente (EL) e da profundidade da câmara vítrea (CV), em ambos os eixos, horizontal (CAH) e vertical (CAV). Os exames oftalmológicos realizados podem ser executados a campo sem comprometer o bem-estar dos animais. Somente na ultrassonografia em modo B foram identificadas diferenças entre os bovinos das raças Nelore e Gir.
Collapse
|
8
|
Suyama Y, Matsuda K, Teshima T, Matsumoto H, Koyama H. The effect of environmental and biological factors on STT I and normal total tear protein concentration in Japanese black calves. J Vet Med Sci 2018; 81:26-29. [PMID: 30449818 PMCID: PMC6361658 DOI: 10.1292/jvms.18-0481] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
To identify reference values for the Schirmer tear test I (STT I) in Japanese black cattle, investigate the effects of variables (sex, age, time of day, and environment in the barn including environmental temperature, humidity, illuminance, and ammonia concentration) on tear production, and determine total tear protein concentration. One-hundred-and-thirty-seven Japanese black cattle (67 females and 70 males, age 3–90 days) were evaluated. The mean STT I values was 18.9 ± 2.9 mm/min (n=263) and significant effects were age and ammonia concentration in the barn. Mean total tear protein concentration was 1.18 ± 0.30 mg/ml in healthy cattle older than 15 days (n=38). It was suggested that age and ammonia concentration are related to fluctuation of tear volume.
Collapse
Affiliation(s)
- Yukino Suyama
- Laboratory of Veterinary Internal Medicine, Department of Veterinary Clinical Medicine, School of Veterinary Medicine Faculty of Veterinary Science, Nippon Veterinary and Life Science University, 1-7-1 Kyonan-cho, Musashino-shi, Tokyo 180-8602, Japan.,Livestock Medical Training Center, Miyagi Prefecture Agricultural Mutual Aid Association, 39-4 Hirabayashi, Ohira, Kurokawa-gun, Miyagi 981-3602, Japan
| | - Keiichi Matsuda
- Livestock Medical Training Center, Miyagi Prefecture Agricultural Mutual Aid Association, 39-4 Hirabayashi, Ohira, Kurokawa-gun, Miyagi 981-3602, Japan
| | - Takahiro Teshima
- Laboratory of Veterinary Internal Medicine, Department of Veterinary Clinical Medicine, School of Veterinary Medicine Faculty of Veterinary Science, Nippon Veterinary and Life Science University, 1-7-1 Kyonan-cho, Musashino-shi, Tokyo 180-8602, Japan
| | - Hirotaka Matsumoto
- Laboratory of Veterinary Internal Medicine, Department of Veterinary Clinical Medicine, School of Veterinary Medicine Faculty of Veterinary Science, Nippon Veterinary and Life Science University, 1-7-1 Kyonan-cho, Musashino-shi, Tokyo 180-8602, Japan
| | - Hidekazu Koyama
- Laboratory of Veterinary Internal Medicine, Department of Veterinary Clinical Medicine, School of Veterinary Medicine Faculty of Veterinary Science, Nippon Veterinary and Life Science University, 1-7-1 Kyonan-cho, Musashino-shi, Tokyo 180-8602, Japan
| |
Collapse
|
9
|
Kurt B, Çağatay HH, Aksoy Ö. The effect of body position on intraocular pressure in calves. J S Afr Vet Assoc 2018; 89:e1-e3. [PMID: 30198297 PMCID: PMC6138144 DOI: 10.4102/jsava.v89i0.1638] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2017] [Revised: 06/27/2018] [Accepted: 07/16/2018] [Indexed: 11/05/2022] Open
Abstract
Tonometry is one of the basic diagnostic tests used for the diagnosis of glaucoma and uveitis in veterinary ophthalmology. The Icare® Rebound Tonometer which is a new tonometric device has been shown to be useful in a wide range of species. Eyes (n = 48) of 24 Simmental and Montafon calves with a mean age of 7.5 weeks (2–16 weeks), male and female, were subjected to intraocular pressure (IOP) measurement using the Icare® Rebound Tonometer with calves standing and in lateral recumbency. The mean IOP was measured as 9.02 ± 2.38 mmHg in the right eye and 9.08 ± 2.55 mmHg in the left eye. No age-related change was found in intraocular pressure of the calves between 2 and 16 weeks of age. No difference in IOP values was observed between Simmental and Montafon calves. Body position had no effect on IOP in calves. The Icare® Rebound Tonometer was shown to be a suitable diagnostic device for IOP measurement in calves.
Collapse
Affiliation(s)
- Başak Kurt
- Department of Surgery, Kafkas University.
| | | | | |
Collapse
|
10
|
Hibbs CD, Barrett PM, Dees DD. Intraocular pressure reference intervals in eyes of clinically normal miniature donkeys (Equus africanus
asinus). Vet Ophthalmol 2018. [DOI: 10.1111/vop.12561] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
11
|
McDonald JE, Knollinger AM, Dees DD, MacLaren NE. Determination of Schirmer tear test-1 values in clinically normal alpacas (Vicugña pacos
) in North America. Vet Ophthalmol 2017; 21:101-103. [DOI: 10.1111/vop.12466] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
| | | | - Darryl D. Dees
- Eye Care for Animals; 12419 Metric Blvd Austin TX 78758 USA
| | | |
Collapse
|
12
|
Marzok MA, Badawy AM, El-Khodery SA. Reference values and repeatability of the Schirmer tear tests I and II in domesticated, clinically normal dromedary camels (Camelus dromedarius). Vet Ophthalmol 2016; 20:259-265. [PMID: 27491827 DOI: 10.1111/vop.12411] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
OBJECTIVE To determine the normal values and repeatability for Schirmer tear test (STT) in clinically normal dromedary camels and to analyze the influence of the age and gender on these values. ANIMALS STUDIED Thirty clinically normal dromedary camels of different ages (calves, immature, and mature). PROCEDURES Schirmer tear tests I and II were performed using commercial STT strips. Three measurements were obtained from each eye over three consecutive weeks, and the variance of these measurements was determined. RESULTS Mean values and coefficient of variation of STT I and STT II for the right and left eyes varied significantly among camel groups (P < 0.05). For STT I, the most frequently recorded values were >14-18, > 22-26, and >30-34 mm/min in calves, immature camels, and mature camels, respectively. For STT II, however, the most frequently recorded values were 7-14, >10-18, and >26-30 mm/min, respectively. The interassay coefficients of variation were 1.7-14.4% and were significantly lower in mature camels than in calves and immature camels (P < 0.05). Age was positively correlated with STT I (r = 0.81) and STT II values (r = 0.88). No significant variations were found between genders. CONCLUSIONS This preliminary study reports STT I and II values and repeatability in normal dromedary camels. This information may assist veterinary practitioners in complete ophthalmic examinations and in accurate diagnosis of ocular surface diseases affecting the tear film in this species.
Collapse
Affiliation(s)
- Mohamed A Marzok
- Department of Veterinary Surgery, Faculty of Veterinary Medicine, Kafrelsheikh University, Kafr El-Sheikh, 33516, Egypt
| | - Adel M Badawy
- Department of Veterinary Surgery, Faculty of Veterinary Medicine, Benha University, Toukh, 13736, Egypt
| | - Sabry A El-Khodery
- Department of Internal Medicine and Infectious Diseases, Faculty of Veterinary Medicine, Mansoura University, Mansoura, 35516, Egypt
| |
Collapse
|
13
|
McDonald JE, Knollinger AM, Dustin Dees D, MacLaren NE. Comparison of intraocular pressure measurements using rebound (TonoVet®) and applanation (TonoPen-XL®) tonometry in clinically normal alpacas (Vicugña pacos). Vet Ophthalmol 2016; 20:155-159. [DOI: 10.1111/vop.12384] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
| | | | - D. Dustin Dees
- Eye Care for Animals; 12419 Metric Blvd Austin TX 78758 USA
| | | |
Collapse
|