1
|
Karageorgos GM, Kemper P, Lee C, Weber R, Kwon N, Meshram N, Mobadersany N, Grondin J, Marshall RS, Miller EC, Konofagou EE. Adaptive Wall Shear Stress Imaging in Phantoms, Simulations and In Vivo. IEEE Trans Biomed Eng 2023; 70:154-165. [PMID: 35776824 PMCID: PMC10103592 DOI: 10.1109/tbme.2022.3186854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
WSS measurement is challenging since it requires sensitive flow measurements at a distance close to the wall. The aim of this study is to develop an ultrasound imaging technique which combines vector flow imaging with an unsupervised data clustering approach that automatically detects the region close to the wall with optimally linear flow profile, to provide direct and robust WSS estimation. The proposed technique was evaluated in phantoms, mimicking normal and atherosclerotic vessels, and spatially registered Fluid Structure Interaction (FSI) simulations. A relative error of 6.7% and 19.8% was obtained for peak systolic (WSSPS) and end diastolic (WSSED) WSS in the straight phantom, while in the stenotic phantom, a good similarity was found between measured and simulated WSS distribution, with a correlation coefficient, R, of 0.89 and 0.85 for WSSPS and WSSED, respectively. Moreover, the feasibility of the technique to detect pre-clinical atherosclerosis was tested in an atherosclerotic swine model. Six swines were fed atherogenic diet, while their left carotid artery was ligated in order to disturb flow patterns. Ligated arterial segments that were exposed to low WSSPS and WSS characterized by high frequency oscillations at baseline, developed either moderately or highly stenotic plaques (p < 0.05). Finally, feasibility of the technique was demonstrated in normal and atherosclerotic human subjects. Atherosclerotic carotid arteries with low stenosis had lower WSSPS as compared to control subjects (p < 0.01), while in one subject with high stenosis, elevated WSS was found on an arterial segment, which coincided with plaque rupture site, as determined through histological examination.
Collapse
|
2
|
Biofabrication of Collagen Tissue-Engineered Blood Vessels with Direct Co-Axial Extrusion. Int J Mol Sci 2022; 23:ijms23105618. [PMID: 35628424 PMCID: PMC9144639 DOI: 10.3390/ijms23105618] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Revised: 05/14/2022] [Accepted: 05/16/2022] [Indexed: 02/04/2023] Open
Abstract
Cardiovascular diseases are considered one of the worldwide causes of death, with atherosclerosis being the most predominant. Nowadays, the gold standard treatment is blood vessel replacement by bypass surgery; however, autologous source is not always possible. Thereby, tissue-engineered blood vessels (TEBVs) are emerging as a potential alternative source. In terms of composition, collagen has been selected in many occasions to develop TEBVs as it is one of the main extracellular matrix components of arteries. However, it requires specific support or additional processing to maintain the tubular structure and appropriate mechanical properties. Here, we present a method to develop support-free collagen TEBVs with co-axial extrusion in a one-step procedure with high concentrated collagen. The highest concentration of collagen of 20 mg/mL presented a burst pressure of 619.55 ± 48.77 mmHg, being able to withstand perfusion of 10 dynes/cm2. Viability results showed a high percentage of viability (86.1 and 85.8% with 10 and 20 mg/mL, respectively) of human aortic smooth muscle cells (HASMCs) and human umbilical vein endothelial cells (HUVEC) after 24 h extrusion. Additionally, HUVEC and HASMCs were mainly localized in their respective layers, mimicking the native distribution. All in all, this approach allows the direct extrusion of collagen TEBVs in a one-step procedure with enough mechanical properties to be perfused.
Collapse
|
3
|
Barrow-McGee R, Procter J, Owen J, Woodman N, Lombardelli C, Kothari A, Kovacs T, Douek M, George S, Barry PA, Ramsey K, Gibson A, Buus R, Holgersen E, Natrajan R, Haider S, Shattock MJ, Gillett C, Tutt AN, Pinder SE, Naidoo K. Real-time ex vivo perfusion of human lymph nodes invaded by cancer (REPLICANT): a feasibility study. J Pathol 2019; 250:262-274. [PMID: 31755096 PMCID: PMC7065097 DOI: 10.1002/path.5367] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2019] [Revised: 11/06/2019] [Accepted: 11/18/2019] [Indexed: 01/18/2023]
Abstract
Understanding how breast cancer (BC) grows in axillary lymph nodes (ALNs), and refining how therapies might halt that process, is clinically important. However, modelling the complex ALN microenvironment is difficult, and no human models exist at present. We harvested ALNs from ten BC patients, and perfused them at 37 °C ex vivo for up to 24 h. Controlled autologous testing showed that ALNs remain viable after 24 h of ex vivo perfusion: haematoxylin and eosin-stained histological appearance and proliferation (by Ki67 immunohistochemistry) did not change significantly over time for any perfused ALN compared with a control from time-point zero. Furthermore, targeted gene expression analysis (NanoString PanCancer IO360 panel) showed that only 21/750 genes were differentially expressed between control and perfused ALNs (|log2 FC| > 1 and q < 0.1): none were involved in apoptosis and metabolism, but rather all 21 genes were involved in immune function and angiogenesis. During perfusion, tissue acid-base balance remained stable. Interestingly, the flow rate increased (p < 0.001) in cancer-replaced (i.e. metastasis occupied more than 90% of the surface area on multiple levels) compared to cancer-free nodes (i.e. nodes with no metastasis on multiple sections). CXCL11 transcripts were significantly more abundant in cancer-replaced nodes, while CXCL12 transcripts were significantly more abundant in cancer-free nodes. These cytokines were also detected in the circulating perfusate. Monoclonal antibodies (nivolumab and trastuzumab) were administered into a further three ALNs to confirm perfusion efficacy. These drugs saturated the nodes; nivolumab even induced cancer cell death. Normothermic ALN perfusion is not only feasible but sustains the tumour microenvironment ex vivo for scientific investigation. This model could facilitate the identification of actionable immuno-oncology targets. © 2019 The Authors. The Journal of Pathology published by John Wiley & Sons Ltd on behalf of Pathological Society of Great Britain and Ireland.
Collapse
Affiliation(s)
- Rachel Barrow-McGee
- Toby Robins Breast Cancer Now Research Centre, Breast Cancer Research Division, The Institute of Cancer Research, London, UK
| | - Julia Procter
- Toby Robins Breast Cancer Now Research Centre, Breast Cancer Research Division, The Institute of Cancer Research, London, UK
| | - Julie Owen
- King's Health Partners Cancer Biobank, Guy's Comprehensive Cancer Centre, London, UK
| | - Natalie Woodman
- King's Health Partners Cancer Biobank, Guy's Comprehensive Cancer Centre, London, UK
| | - Cristina Lombardelli
- King's Health Partners Cancer Biobank, Guy's Comprehensive Cancer Centre, London, UK
| | | | - Tibor Kovacs
- Guy's and St. Thomas' Hospital NHS Foundation Trust, London, UK
| | - Michael Douek
- School of Cancer and Pharmaceutical Sciences, King's College London, Guy's Comprehensive Cancer Centre, London, UK
| | - Simi George
- Department of Cellular Pathology, Guy's and St. Thomas' Hospital NHS Foundation Trust, London, UK
| | | | | | - Amy Gibson
- Toby Robins Breast Cancer Now Research Centre, Breast Cancer Research Division, The Institute of Cancer Research, London, UK
| | - Richard Buus
- Toby Robins Breast Cancer Now Research Centre, Breast Cancer Research Division, The Institute of Cancer Research, London, UK.,Ralph Lauren Centre for Breast Cancer Research, Royal Marsden Hospital, London, UK
| | - Erle Holgersen
- Toby Robins Breast Cancer Now Research Centre, Breast Cancer Research Division, The Institute of Cancer Research, London, UK
| | - Rachael Natrajan
- Toby Robins Breast Cancer Now Research Centre, Breast Cancer Research Division, The Institute of Cancer Research, London, UK
| | - Syed Haider
- Toby Robins Breast Cancer Now Research Centre, Breast Cancer Research Division, The Institute of Cancer Research, London, UK
| | - Michael J Shattock
- British Heart Foundation Centre of Research Excellence, King's College London, St Thomas' Hospital, London, UK
| | - Cheryl Gillett
- King's Health Partners Cancer Biobank, Guy's Comprehensive Cancer Centre, London, UK
| | - Andrew Nj Tutt
- Toby Robins Breast Cancer Now Research Centre, Breast Cancer Research Division, The Institute of Cancer Research, London, UK
| | - Sarah E Pinder
- School of Cancer and Pharmaceutical Sciences, King's College London, Guy's Comprehensive Cancer Centre, London, UK
| | - Kalnisha Naidoo
- Toby Robins Breast Cancer Now Research Centre, Breast Cancer Research Division, The Institute of Cancer Research, London, UK.,Department of Cellular Pathology, Guy's and St. Thomas' Hospital NHS Foundation Trust, London, UK
| |
Collapse
|
4
|
Bernal M, Sen I, Urban MW. Evaluation of materials used for vascular anastomoses using shear wave elastography. ACTA ACUST UNITED AC 2019; 64:075001. [DOI: 10.1088/1361-6560/ab055c] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
5
|
Arterial wall remodeling under sustained axial twisting in rats. J Biomech 2017; 60:124-133. [PMID: 28693818 DOI: 10.1016/j.jbiomech.2017.06.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2016] [Revised: 06/13/2017] [Accepted: 06/14/2017] [Indexed: 01/03/2023]
Abstract
Blood vessels often experience torsion along their axes and it is essential to understand their biological responses and wall remodeling under torsion. To this end, a rat model was developed to investigate the arterial wall remodeling under sustained axial twisting in vivo. Rat carotid arteries were twisted at 180° along the longitudinal axis through a surgical procedure and maintained for different durations up to 4weeks. The wall remodeling in these twisted arteries was examined using histology, immunohistochemistry and fluorescent microscopy. Our data showed that arteries remodeled under twisting in a time-dependent manner during the 4weeks post-surgery. Cell proliferation, MMP-2 and MMP-9 expressions, medial wall thickness and lumen diameter increased while collagen to elastin ratio decreased. The size and number of internal elastic lamina fenestrae increased with elongated shapes, while the endothelial cells elongated and aligned towards the blood flow direction gradually. These results demonstrated that sustained axial twisting results in artery remodeling in vivo. The rat carotid artery twisting model is an effective in vivo model for studying arterial wall remodeling under long-term torsion. These results enrich our understanding of vascular biology and arterial wall remodeling under mechanical stresses.
Collapse
|
6
|
Martin KH, Lindsey BD, Ma J, Nichols TC, Jiang X, Dayton PA. Ex Vivo Porcine Arterial and Chorioallantoic Membrane Acoustic Angiography Using Dual-Frequency Intravascular Ultrasound Probes. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:2294-307. [PMID: 27260246 PMCID: PMC5653969 DOI: 10.1016/j.ultrasmedbio.2016.04.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2015] [Revised: 02/11/2016] [Accepted: 04/08/2016] [Indexed: 05/03/2023]
Abstract
The presence of blood vessels within a developing atherosclerotic plaque has been found to be correlated with increased plaque vulnerability and ensuing cardiac events, however, detection of coronary intraplaque neovascularization poses a significant challenge in the clinic. We describe here a new in vivo intravascular ultrasound imaging method using a dual-frequency transducer to visualize contrast flow in microvessels with high specificity. This method uses a specialized transducer capable of exciting contrast agents at a low frequency (5.5 MHz) while detecting their nonlinear superhamonics at a much higher frequency (37 MHz). In vitro evaluation of the approach was performed in a microvascular phantom to produce 3-D renderings of simulated vessel patterns and to determine image quality metrics as a function of depth. Furthermore, we describe the ability of the system to detect microvessels both ex vivo using porcine arteries and in vivo using the chorioallantoic membrane of a developing chicken embryo with optical confirmation. Dual-frequency contrast-specific imaging was able to resolve vessels similar in size to those found in vulnerable atherosclerotic plaques at clinically relevant depths. The results of this study add to the support for further evaluation and translation of contrast-specific imaging in intravascular ultrasound for the detection of vulnerable plaques in atherosclerosis.
Collapse
Affiliation(s)
- K Heath Martin
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Chapel Hill, North Carolina, USA
| | - Brooks D Lindsey
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Chapel Hill, North Carolina, USA
| | - Jianguo Ma
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina, USA
| | - Timothy C Nichols
- Department of Pathology and Laboratory Medicine, University of North Carolina, Chapel Hill, North Carolina, USA
| | - Xiaoning Jiang
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina, USA
| | - Paul A Dayton
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Chapel Hill, North Carolina, USA; Biomedical Research Imaging Center, University of North Carolina, Chapel Hill, North Carolina, USA.
| |
Collapse
|
7
|
Lindsey BD, Martin KH, Jiang X, Dayton PA. Adaptive windowing in contrast-enhanced intravascular ultrasound imaging. ULTRASONICS 2016; 70:123-35. [PMID: 27161022 PMCID: PMC4899141 DOI: 10.1016/j.ultras.2016.04.022] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2015] [Revised: 04/06/2016] [Accepted: 04/26/2016] [Indexed: 05/23/2023]
Abstract
Intravascular ultrasound (IVUS) is one of the most commonly-used interventional imaging techniques and has seen recent innovations which attempt to characterize the risk posed by atherosclerotic plaques. One such development is the use of microbubble contrast agents to image vasa vasorum, fine vessels which supply oxygen and nutrients to the walls of coronary arteries and typically have diameters less than 200μm. The degree of vasa vasorum neovascularization within plaques is positively correlated with plaque vulnerability. Having recently presented a prototype dual-frequency transducer for contrast agent-specific intravascular imaging, here we describe signal processing approaches based on minimum variance (MV) beamforming and the phase coherence factor (PCF) for improving the spatial resolution and contrast-to-tissue ratio (CTR) in IVUS imaging. These approaches are examined through simulations, phantom studies, ex vivo studies in porcine arteries, and in vivo studies in chicken embryos. In phantom studies, PCF processing improved CTR by a mean of 4.2dB, while combined MV and PCF processing improved spatial resolution by 41.7%. Improvements of 2.2dB in CTR and 37.2% in resolution were observed in vivo. Applying these processing strategies can enhance image quality in conventional B-mode IVUS or in contrast-enhanced IVUS, where signal-to-noise ratio is relatively low and resolution is at a premium.
Collapse
Affiliation(s)
- Brooks D Lindsey
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, CB7575 Chapel Hill, NC 27599, United States.
| | - K Heath Martin
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, CB7575 Chapel Hill, NC 27599, United States
| | - Xiaoning Jiang
- Department of Mechanical and Aerospace Engineering, North Carolina State University, 911 Oval Drive, 3282 Engineering Building III, Campus Box 7910, North Carolina State University, Raleigh, NC, United States; Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, CB7575 Chapel Hill, NC 27599, United States
| | - Paul A Dayton
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, CB7575 Chapel Hill, NC 27599, United States; Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Marsico Hall, Chapel Hill, NC 27599, United States
| |
Collapse
|
8
|
Novel Sensor-Enabled Ex Vivo Bioreactor: A New Approach towards Physiological Parameters and Porcine Artery Viability. BIOMED RESEARCH INTERNATIONAL 2015; 2015:958170. [PMID: 26609536 PMCID: PMC4644552 DOI: 10.1155/2015/958170] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/24/2014] [Revised: 03/12/2015] [Accepted: 03/18/2015] [Indexed: 11/18/2022]
Abstract
The aim of the present work is to design and construct an ex vivo bioreactor system to assess the real time viability of vascular tissue. Porcine carotid artery as a model tissue was used in the ex vivo bioreactor setup to monitor its viability under physiological conditions such as oxygen, pressure, temperature, and flow. The real time tissue viability was evaluated by monitoring tissue metabolism through a fluorescent indicator "resorufin." Our ex vivo bioreactor allows real time monitoring of tissue responses along with physiological conditions. These ex vivo parameters were vital in determining the tissue viability in sensor-enabled bioreactor and our initial investigations suggest that, porcine tissue viability is considerably affected by high shear forces and low oxygen levels. Histological evaluations with hematoxylin and eosin and Masson's trichrome staining show intact endothelium with fresh porcine tissue whereas tissues after incubation in ex vivo bioreactor studies indicate denuded endothelium supporting the viability results from real time measurements. Hence, this novel viability sensor-enabled ex vivo bioreactor acts as model to mimic in vivo system and record vascular responses to biopharmaceutical molecules and biomedical devices.
Collapse
|
9
|
Wang GL, Xiao Y, Voorhees A, Qi YX, Jiang ZL, Han HC. Artery Remodeling Under Axial Twist in Three Days Organ Culture. Ann Biomed Eng 2014; 43:1738-47. [PMID: 25503524 DOI: 10.1007/s10439-014-1215-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2014] [Accepted: 12/04/2014] [Indexed: 11/28/2022]
Abstract
Arteries often endure axial twist due to body movement and surgical procedures, but how arteries remodel under axial twist remains unclear. The objective of this study was to investigate early stage arterial wall remodeling under axial twist. Porcine carotid arteries were twisted axially and maintained for three days in ex vivo organ culture systems while the pressure and flow remained the same as untwisted controls. Cell proliferation, internal elastic lamina (IEL) fenestrae shape and size, endothelial cell (EC) morphology and orientation, as well as the expression of matrix metalloproteinases (MMPs), MMP-2 and MMP-9, and tissue inhibitor of metalloproteinase-2 (TIMP-2) were quantified using immunohistochemistry staining and immunoblotting. Our results demonstrated that cell proliferation in both the intima and media were significantly higher in the twisted arteries compared to the controls. The cell proliferation in the intima increased from 1.33 ± 0.21% to 7.63 ± 1.89%, and in the media from 1.93 ± 0.84% to 8.27 ± 2.92% (p < 0.05). IEL fenestrae total area decreased from 26.07 ± 2.13% to 14.74 ± 0.61% and average size decreased from 169.03 ± 18.85 μm(2) to 80.14 ± 1.96 μm(2) (p < 0.01), but aspect ratio increased in the twist group from 2.39 ± 0.15 to 2.83 ± 0.29 (p < 0.05). MMP-2 expression significantly increased (p < 0.05) while MMP-9 and TIMP-2 showed no significant difference in the twist group. The ECs in the twisted arteries were significantly elongated compared to the controls after three days. The angle between the major axis of the ECs and blood flow direction under twist was 7.46 ± 2.44 degrees after 3 days organ culture, a decrease from the initial 15.58 ± 1.29 degrees. These results demonstrate that axial twist can stimulate artery remodeling. These findings complement our understanding of arterial wall remodeling under mechanical stress resulting from pressure and flow variations.
Collapse
Affiliation(s)
- Guo-Liang Wang
- Institute of Mechanobiology and Medical Engineering, School of Life Sciences and Biotechnology, Shanghai Jiao Tong University, Shanghai, 200240, China
| | | | | | | | | | | |
Collapse
|
10
|
Behler RH, Czernuszewicz TJ, Wu CD, Nichols TC, Zhu H, Homeister JW, Merricks EP, Gallippi CM. Acoustic radiation force beam sequence performance for detection and material characterization of atherosclerotic plaques: preclinical, ex vivo results. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2013; 60:2471-87. [PMID: 24297014 PMCID: PMC4097991 DOI: 10.1109/tuffc.2013.2847] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
This work presents preclinical data demonstrating performance of acoustic radiation force (ARF)-based elasticity imaging with five different beam sequences for atherosclerotic plaque detection and material characterization. Twelve trained, blinded readers evaluated parametric images taken ex vivo under simulated in vivo conditions of 22 porcine femoral arterial segments. Receiver operating characteristic (ROC) curve analysis was carried out to quantify reader performance using spatially-matched immunohistochemistry for validation. The beam sequences employed had high sensitivity (sens) and specificity (spec) for detecting Type III+ plaques (sens: 85%, spec: 79%), lipid pools (sens: 80%, spec: 86%), fibrous caps (sens: 86%, spec: 82%), calcium (sens: 96%, spec: 85%), collagen (sens: 78%, spec: 77%), and disrupted internal elastic lamina (sens: 92%, spec: 75%). 1:1 single-receive tracking yielded the highest median areas under the ROC curve (AUC), but was not statistically significantly higher than 4:1 parallel-receive tracking. Excitation focal configuration did not result in statistically different AUCs. Overall, these results suggest ARF-based imaging is relevant to detecting and characterizing plaques and support its use for diagnosing and monitoring atherosclerosis.
Collapse
|
11
|
Robertson C, Ikemura K, Krasieva TB, George SC. Multiscale analysis of collagen microstructure with generalized image correlation spectroscopy and the detection of tissue prestress. Biomaterials 2013; 34:6127-32. [PMID: 23642533 DOI: 10.1016/j.biomaterials.2013.04.019] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2013] [Accepted: 04/10/2013] [Indexed: 12/13/2022]
Abstract
Prestress in tissue is currently detected through destructive methods which obviate both in vivo and longitudinal assessment. We hypothesized that prestress could be detected and quantified by analyzing the microstructure of the extracellular matrix at different spatial scales using non-invasive and non-destructive optical imaging. A simple model of tissue prestress was created using fibroblast-mediated contraction of collagen gels around a central mandrel. Using a quantitative, multiscale, image processing technique, termed generalized image correlation spectroscopy (GICS) of second harmonic images, collagen fiber number and alignment at three different length scales characteristic of the collagen fibril, collagen fiber, and cell were analyzed. GICS fiber alignment (σ(maj/min)) was significantly different across load state, level of prestress, and length scale. The largest fiber ratio, and thus highest alignment, was seen in prestressed, externally loaded gels at a length scale equivalent to the size of the fibroblast cells. Alignment at both fiber and cell scale correlated with prestress in this model. We conclude that GICS of second harmonic images of collagen can predict prestress, and that microstructural organization at the collagen fiber and cell scale are the primary determinants of prestress in cellularized collagen gels.
Collapse
Affiliation(s)
- Claire Robertson
- Department of Biomedical Engineering, University of California, Irvine, CA, USA
| | | | | | | |
Collapse
|
12
|
Hayman DM, Xiao Y, Yao Q, Jiang Z, Lindsey ML, Han HC. Alterations in Pulse Pressure Affect Artery Function. Cell Mol Bioeng 2012; 5:474-487. [PMID: 23243477 DOI: 10.1007/s12195-012-0251-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
Pulse pressure changes in response to cardiovascular diseases and interventions, but its effect on vascular wall structure and function is poorly understood. We examined the effect of increased or decreased pulse pressure on artery function, cellular function, and extracellular matrix remodeling. Porcine carotid arteries were cultured under non-pulsatile (100 mmHg), pulsatile (70-130 mmHg), or hyper-pulsatile pressure (50-150 mmHg) for 1 to 3 days. Vasomotor response, wall permeability, cell proliferation, apoptosis, extracellular matrix remodeling, and proteins involved in atherogenesis were examined. Our results showed that hyper-pulsatile pressure decreased the artery response to sodium nitroprusside, basal tone, and wall permeability after three days. Non-pulsatile pressure increased cell proliferation. Neither hyper-pulsatile nor non-pulsatile pressure caused a change in the extracellular matrix or in the expression of matrix metalloproteinase-2 (MMP-2), MMP-9, caveolin-1, or α-actin. Hyper-pulsatile pressure increased monocyte chemotactic protein-1 gene expression. Taken together, these changes indicate that pulse pressure has a limited effect on the artery immediately after its application. Specifically an increase in pulse pressure alters the artery tone and wall permeability while a decrease in pulse pressure alters cell proliferation. Overall these results provide insight into how the artery initially responds to changes in pulse pressure.
Collapse
Affiliation(s)
- Danika M Hayman
- Department of Mechanical Engineering, University of Texas at San Antonio, China ; Biomedical Engineering Program, UTSA-UTHSCSA, China
| | | | | | | | | | | |
Collapse
|
13
|
NIROOMAND OSCUII HANIEH, TAFAZZOLI-SHADPOUR MOHAMMAD, GHALICHI FARZAN. BIOMECHANICAL ANALYSIS OF WALL REMODELING IN ELASTIC ARTERIES WITH APPLICATION OF FLUID–SOLID INTERACTION METHODS. J MECH MED BIOL 2011. [DOI: 10.1142/s0219519407002418] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The effects of age-related hypertrophic remodeling of the thoracic aortic wall on mechanical stresses are quantified using the fluid–solid interaction method. Boundary conditions include physiological flow and pressure waves. Fluid and solid governing equations are solved using the loose coupling method. The results show alteration of hemodynamic and wall mechanical parameters by the remodeling process, including reduction in maximum circumferential stress and lower shear stress fluctuation with smaller portion of negative value and smaller maximum value. Such characteristics are indicators of the reduction of risk of endothelial injury. Remodeling causes elevation of the stress phase angle, an indicator of interaction between shear and circumferential stresses that causes triggering of endothelial cell proliferation, which is necessary for coverage of extra surface required by remodeling. The improvement by remodeling is limited by age-related structural changes such as elastin dysfunction and disorganization of structural components.
Collapse
Affiliation(s)
- HANIEH NIROOMAND OSCUII
- Faculty of Biomedical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran
| | | | - FARZAN GHALICHI
- Biomedical Engineering Group, Sahand University of Technology, Tabriz, Iran
| |
Collapse
|
14
|
Effects of Hypertension on Morphological, Contractile and Mechanical Properties of Rat Aortic Smooth Muscle Cells. Cell Mol Bioeng 2011. [DOI: 10.1007/s12195-011-0182-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|
15
|
Bernal M, Nenadic I, Urban MW, Greenleaf JF. Material property estimation for tubes and arteries using ultrasound radiation force and analysis of propagating modes. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2011; 129:1344-54. [PMID: 21428498 PMCID: PMC3078026 DOI: 10.1121/1.3533735] [Citation(s) in RCA: 132] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Arterial elasticity has been proposed as an independent predictor of cardiovascular diseases and mortality. Identification of the different propagating modes in thin shells can be used to characterize the elastic properties. Ultrasound radiation force was used to generate local mechanical waves in the wall of a urethane tube or an excised pig carotid artery. The waves were tracked using pulse-echo ultrasound. A modal analysis using two-dimensional discrete fast Fourier transform was performed on the time-space signal. This allowed the visualization of different modes of propagation and characterization of dispersion curves for both structures. The urethane tube/artery was mounted in a metallic frame, embedded in tissue-mimicking gelatin, cannulated, and pressurized over a range of 10-100 mmHg. The k-space and the dispersion curves of the urethane tube showed one mode of propagation, with no effect of transmural pressure. Fitting of a Lamb wave model estimated Young's modulus in the urethane tube around 560 kPa. Young's modulus of the artery ranged from 72 to 134 kPa at 10 and 100 mmHg, respectively. The changes observed in the artery dispersion curves suggest that this methodology of exciting mechanical waves and characterizing the modes of propagation has potential for studying arterial elasticity.
Collapse
Affiliation(s)
- Miguel Bernal
- Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, 200 First Street Southwest, Rochester, Minnesota 55905, USA.
| | | | | | | |
Collapse
|
16
|
Kamat N, Nguyen-Ehrenreich KLT, Hsu SH, Ma AP, Sinn I, Coleman L, Tai J. Characterization of Vascular Injury Responses to Stent Insertion in an Ex-vivo Arterial Perfusion Model. J Vasc Interv Radiol 2011; 22:193-202. [DOI: 10.1016/j.jvir.2010.10.006] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2010] [Revised: 05/30/2010] [Accepted: 10/12/2010] [Indexed: 11/28/2022] Open
|
17
|
Effects of Axial Stretch on Cell Proliferation and Intimal Thickness in Arteries in Organ Culture. Cell Mol Bioeng 2010; 3:286-295. [PMID: 21116478 DOI: 10.1007/s12195-010-0128-9] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
Intimal hyperplasia (IH) remains the major cause of intermediate and long-term failure of vascular grafts and endovascular interventions. Arteries are subjected to a significant longitudinal stress in addition to the shear stress and tensile stress from the blood flow. The aim of this study was to determine the effect of axial stretch on cell proliferation and IH in arteries. Porcine carotid arteries, intact or endothelial cell (EC) denudated, were maintained ex vivo at different stretch ratios (1.3, 1.5, and 1.8) and flow rates (16 or 160 mL/min) while remaining at physiologic pressure for 7 days. The viability of the arteries was verified with norepinephrine, carbachol, and sodium nitroprusside stimulations, and the cell proliferation was detected using bromodeoxyuridine labeling and immunostaining. Our results showed that the axial stretch ratio did not significantly affect intimal thickness and cell proliferation in normal arteries. However, axial stretch increased the neointimal thickness in EC denudated arteries cultured under low flow conditions. The cell proliferation increased significantly in the intima and inner half of the media of the EC denudated arteries under normal or elevated axial stretch in comparison to intact arteries at the same stretch ratio. These results demonstrated that axial stretch with EC denudation and low flow increases neointimal formation and cell proliferation in the arteries.
Collapse
|
18
|
Wang R, Gleason RL. A mechanical analysis of conduit arteries accounting for longitudinal residual strains. Ann Biomed Eng 2010; 38:1377-87. [PMID: 20087772 DOI: 10.1007/s10439-010-9916-6] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2009] [Accepted: 01/05/2010] [Indexed: 10/19/2022]
Abstract
Identification of an appropriate stress-free reference configuration is critically important in providing a reasonable prediction of the intramural stress distribution when performing biomechanical analyses on arteries. The stress-free state is commonly approximated as a radially cut ring that typically opens into a nearly circular sector, relieving much of the circumferential residual strains that exist in the traction-free configuration. An opening angle is often used to characterize this sector. In this study, we first present experimental results showing significant residual deformations in the longitudinal direction of two commonly studied arteries in the pig: the common carotid artery and the left anterior descending coronary artery. We concluded that a radially cut ring cannot completely describe the stress-free state of the arteries. Instead, we propose the use of a longitudinal opening angle, in conjunction with the traditional circumferential opening angle, to experimentally quantify the stress-free state of an artery. Secondly, we propose a new kinematic model to account for the addition of longitudinal residual strains through employing the longitudinal opening angle and performed a stress analysis. We found that with the inclusion of longitudinal residual strains in the stress analysis, the predicted circumferential stress gradient was decreased by 3-fold and the predicted longitudinal stress gradient was increased by 5.7-fold. Thus, inclusion of longitudinal residual strains has a significant effect on the predicted stress distribution in arteries.
Collapse
Affiliation(s)
- Ruoya Wang
- George W Woodruff School of Mechanical Engineering, Georgia Institute of Technology, 315 Ferst Drive, Atlanta, GA 30332, USA
| | | |
Collapse
|
19
|
Lawrence AR, Gooch KJ. Differences in transmural pressure and axial loading ex vivo affect arterial remodeling and material properties. J Biomech Eng 2010; 131:101009. [PMID: 19831479 DOI: 10.1115/1.3200910] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Arterial axial strains, present in the in vivo environment, often become reduced due to either bypass grafting or the normal aging process. Since the prevalence of hypertension increases with aging, arteries are often exposed to both decreased axial stretch and increased transmural pressure. The combined effects of these mechanical stimuli on the mechanical properties of vessels have not previously been determined. Porcine carotid arteries were cultured for 9 days at normal and reduced axial stretch ratios in the presence of normotensive and hypertensive transmural pressures using ex vivo perfusion techniques. Measurements of the amount of axial stress were obtained through longitudinal tension tests while inflation-deflation test results were used to determine circumferential stresses and incremental moduli. Macroscopic changes in artery geometry and zero-stress state opening angles were measured. Arteries cultured ex vivo remodeled in response to the mechanical environment, resulting in changes in arterial dimensions of up to approximately 25% and changes in zero-stress opening angles of up to approximately 55 degrees . While pressure primarily affected circumferential remodeling and axial stretch primarily affected axial remodeling, there were clear examples of interactions between these mechanical stimuli. Culture with hypertensive pressure, especially when coupled with reduced axial loading, resulted in a rightward shift in the pressure-diameter relationship relative to arteries cultured with normotensive pressure. The observed differences in the pressure-diameter curves for cultured arteries were due to changes in artery geometry and, in some cases, changes in the arteries' intrinsic mechanical properties. Relative to freshly isolated arteries, arteries cultured under mechanical conditions similar to in vivo conditions were stiffer, suggesting that aspects of the ex vivo culture other than the mechanical environment also influenced changes in the arteries' mechanical properties. These results confirm the well-known importance of transmural pressure with regard to arterial wall mechanics while highlighting additional roles for axial stretch in determining mechanical behavior.
Collapse
Affiliation(s)
- Amanda R Lawrence
- Department of Bioengineering and Institute for Medicine and Engineering, University of Pennsylvania, Philadelphia, 19104, USA
| | | |
Collapse
|
20
|
Rachev A, Dominguez Z, Vito R. System and method for investigating arterial remodeling. J Biomech Eng 2010; 131:104501. [PMID: 19831489 DOI: 10.1115/1.3207014] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Organ culture systems are used to study remodeling of arteries and to fabricate tissue engineered vascular grafts. Investigations to date focused on changes in geometry and mechanical response of arteries or constructs associated with controlled sustained alterations in the global load parameters such as the arterial pressure, flow, or axial stretch. A new experimental paradigm is proposed, which is based on the simultaneous independent control of local mechanical parameters such as mean strain or stress in the arterial wall and flow-induced shear at the intima. An organ culture system and methodology were developed, which controls pressure, flow, and axial length of a specimen in order to maintain the local mechanical parameters at prescribed values. The operation of the system is illustrated by maintenance of elevated axial medial stress in porcine carotid artery, while keeping the mean circumferential stress and flow-induced shear stress at baseline values. Previously unknown aspects of remodeling that might be revealed by the novel approach are discussed.
Collapse
|
21
|
Yao Q, Hayman DM, Dai Q, Lindsey ML, Han HC. Alterations of pulse pressure stimulate arterial wall matrix remodeling. J Biomech Eng 2010; 131:101011. [PMID: 19831481 DOI: 10.1115/1.3202785] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The effect of pulse pressure on arterial wall remodeling has not been clearly defined. The objective of this study was to evaluate matrix remodeling in arteries under nonpulsatile and hyperpulsatile pressure as compared with arteries under normal pulsatile pressure. Porcine carotid arteries were cultured for 3 and 7 days under normal, nonpulsatile, and hyperpulsatile pressures with the same mean pressure and flow rate using an ex vivo organ culture model. Fenestrae in the internal elastic lamina, collagen, fibronectin, and gap junction protein connexin 43 were examined in these arteries using confocal microscopy, immunoblotting, and immunohistochemistry. Our results showed that after 7 days, the mean fenestrae size and the area fraction of fenestrae decreased significantly in nonpulsatile arteries (51% and 45%, respectively) and hyperpulsatile arteries (45% and 54%, respectively) when compared with normal pulsatile arteries. Fibronectin decreased (29.9%) in nonpulsatile arteries after 3 days but showed no change after 7 days, while collagen I levels increased significantly (106%) in hyperpulsatile arteries after 7 days. The expression of connexin 43 increased by 35.3% in hyperpulsatile arteries after 7 days but showed no difference in nonpulsatile arteries. In conclusion, our results demonstrated, for the first time, that an increase or a decrease in pulse pressure from its normal physiologic level stimulates structural changes in the arterial wall matrix. However, hyperpulsatile pressure has a more pronounced effect than the diminished pulse pressure. This effect helps to explain the correlation between increasing wall stiffness and increasing pulse pressure in vivo.
Collapse
Affiliation(s)
- Qingping Yao
- Department of Mechanical Engineering, University of Texas at San Antonio, 78249, USA
| | | | | | | | | |
Collapse
|
22
|
Comparison of artery organ culture and co-culture models for studying endothelial cell migration and its effect on smooth muscle cell proliferation and migration. Ann Biomed Eng 2009; 38:801-12. [PMID: 20033777 DOI: 10.1007/s10439-009-9877-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2009] [Accepted: 12/14/2009] [Indexed: 12/19/2022]
Abstract
Arterial restenosis associated with intimal hyperplasia is the major cause of long-term failure of vascular interventions. Endothelium injury and the proliferation and migration of smooth muscle cells (SMC) are key events in the development of intimal hyperplasia. The objectives of this study were to develop an ex vivo artery injury model for studying endothelial cell (EC) migration and to compare it with an in vitro co-culture arterial wall injury model in terms of the effect of flow on EC migration and its effect on SMC migration and proliferation. Our results demonstrated that shear flow improves reendothelialization in the injured area by promoting EC migration. The migration distance of ECs is much smaller in the arteries than in an in vitro cell culture model (3.57+/-1.29 mm vs. 5.2+/-1.4 cm, p<0.001). SMC proliferation was significantly less in the EC intact and reendothelialization areas than in the EC denuded areas indicating that reendothelialization suppresses SMC proliferation. Our models provide a new approach to study techniques to enhance endothelium healing.
Collapse
|
23
|
Lawrence AR, Gooch KJ. Transmural pressure and axial loading interactively regulate arterial remodeling ex vivo. Am J Physiol Heart Circ Physiol 2009; 297:H475-84. [PMID: 19465545 DOI: 10.1152/ajpheart.00972.2008] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Physiological axial strains range between 40 and 60% in arteries, resulting in stresses comparable to those due to normal blood pressure or flow. To investigate the contribution of axial strain to arterial remodeling and function, porcine carotid arteries were cultured for 9 days at physiological and reduced axial stretch ratios in the presence of normotensive and hypertensive transmural pressures by ex vivo perfusion techniques. Consistent with previous in vivo studies, vessels cultured with physiological levels of axial strain and exposed to hypertensive pressure had greater mass, wall area, and outer diameter relative to those cultured at the same axial stretch ratio and normotensive pressure. Reducing the amount of axial strain resulted in mass loss and decreased cell proliferation. Culture in a hypertensive pressure environment at reduced axial strain produced arteries with greater contractility in response to norepinephrine. Arteries cultured at reduced axial strain with the matrix metalloproteinase inhibitor GM6001 maintained their masses over culture, indicating a possible mechanism for this model of axial stretch-dependent remodeling. Although not historically considered one of the primary stimuli for remodeling, multiple linear regression analysis revealed that axial strain had an impact similar to or greater than transmural pressure on various remodeling indexes (i.e., outer diameter, wall area, and wet mass), suggesting that axial strain is a primary mediator of vascular remodeling.
Collapse
Affiliation(s)
- Amanda R Lawrence
- Department of Bioengineering and Institute for Medicine and Engineering, University of Pennsylvania, Philadelphia, PA, USA
| | | |
Collapse
|
24
|
El-Kurdi MS, Vipperman JS, Vorp DA. Design and Subspace System Identification of an Ex Vivo Vascular Perfusion System. J Biomech Eng 2009; 131:041012. [DOI: 10.1115/1.3072895] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Numerical algorithms for subspace system identification (N4SID) are a powerful tool for generating the state space (SS) representation of any system. The purpose of this work was to use N4SID to generate SS models of the flowrate and pressure generation within an ex vivo vascular perfusion system (EVPS). Accurate SS models were generated and converted to transfer functions (TFs) to be used for proportional integral and derivative (PID) controller design. By prescribing the pressure and flowrate inputs to the pumping components within the EVPS and measuring the resulting pressure and flowrate in the system,_four TFs were estimated;_two for a flowrate controller (HRP,f and HRPP,f) and two for a pressure controller (HRP,p and HRPP,p). In each controller,_one TF represents a roller pump (HRP,f and HRP,p),_and the other represents a roller pump and piston in series (HRPP,f and HRPP,p). Experiments to generate the four TFs were repeated five times (N=5) from which average TFs were calculated. The average model fits, computed as the percentage of the output variation (to_the_prescribed_inputs) reproduced by the model, were 94.93±1.05% for HRP,p, 81.29±0.20% for HRPP,p, 94.45±0.73% for HRP,f, and 77.12±0.36% for HRPP,f. The simulated step, impulse, and frequency responses indicate that the EVPS is a stable system and can respond to signals containing power of up to 70_Hz.
Collapse
Affiliation(s)
- Mohammed S. El-Kurdi
- Department of Surgery, Division of Vascular Surgery, University of Pittsburgh, Suite 200, Bridgeside Point, Pittsburgh, PA 15219; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15219; McGowan Institute for Regenerative Medicine, University of Pittsburgh, 100 Technology Drive, Pittsburgh, PA 15219
| | - Jeffrey S. Vipperman
- Department of Mechanical Engineering and Material Science, and Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15219
| | - David A. Vorp
- Department of Surgery, Division of Vascular Surgery, University of Pittsburgh, Suite 200, Bridgeside Point, Pittsburgh, PA 15219; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15219; McGowan Institute for Regenerative Medicine, University of Pittsburgh, 100 Technology Drive, Pittsburgh, PA 15219
| |
Collapse
|
25
|
Kim YS, Galis ZS, Rachev A, Han HC, Vito RP. Matrix metalloproteinase-2 and -9 are associated with high stresses predicted using a nonlinear heterogeneous model of arteries. J Biomech Eng 2009; 131:011009. [PMID: 19045925 PMCID: PMC8455176 DOI: 10.1115/1.3005163] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Arteries adapt to their mechanical environment by undergoing remodeling of the structural scaffold via the action of matrix metalloproteinases (MMPs). Cell culture studies have shown that stretching vascular smooth muscle cells (VSMCs) positively correlates to the production of MMP-2 and -9. In tissue level studies, the expressions and activations of MMP-2 and -9 are generally higher in the outer media. However, homogeneous mechanical models of arteries predict lower stress and strain in the outer media, which appear inconsistent with experimental findings. The effects of heterogeneity may be important to our understanding of VSMC function since arteries exhibit structural heterogeneity across the wall. We hypothesized that local stresses, computed using a heterogeneous mechanical model of arteries, positively correlate to the levels of MMP-2 and -9 in situ. We developed a model of the arterial wall accounting for nonlinearity, residual strain, anisotropy, and structural heterogeneity. The distributions of elastin and collagen fibers in situ, measured in the media of porcine carotid arteries, showed significant nonuniformities. Anisotropy was represented by the direction of collagen fibers measured by the helical angle of VSMC nuclei. The points at which the collagen fibers became load bearing were computed, assuming a uniform fiber strain and orientation under physiological loading conditions, an assumption motivated by morphological measurements. The distributions of circumferential stresses, computed using both heterogeneous and homogeneous models, were correlated to the distributions of expressions and activations of MMP-2 and -9 in porcine common carotid arteries incubated in an ex vivo perfusion organ culture system under physiological conditions for 48 h. While strains computed using incompressibility were identical in both models, the heterogeneous model, unlike the homogeneous model, predicted higher circumferential stresses in the outer layer correlated to the expressions and activations of MMP-2 and -9. This implies that localized remodeling occurs in the areas of high stress and agrees with results from cell culture studies. The results support the role of mechanical stress in vascular remodeling and the importance of structural heterogeneity in understanding mechanobiological responses.
Collapse
Affiliation(s)
- Yu Shin Kim
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, IBB Room 2117, 315 Ferst Drive, Atlanta, GA 30332, USA.
| | | | | | | | | |
Collapse
|
26
|
Miyakawa AA, Dallan LAO, Lacchini S, Borin TF, Krieger JE. Human saphenous vein organ culture under controlled hemodynamic conditions. Clinics (Sao Paulo) 2008; 63:683-8. [PMID: 18925330 PMCID: PMC2664728 DOI: 10.1590/s1807-59322008000500018] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2008] [Accepted: 07/04/2008] [Indexed: 12/02/2022] Open
Abstract
INTRODUCTION Saphenous vein grafting is still widely used to revascularize ischemic myocardium. The effectiveness of this procedure is limited by neointima formation and accelerated atherosclerosis, which frequently leads to graft occlusion. A better understanding of this process is important to clarify the mechanisms of vein graft disease and to aid in the formulation of strategies for prevention and/or therapeutics. OBJECTIVE To develop an ex vivo flow system that allows for controlled hemodynamics in order to mimic arterial and venous conditions. METHODS Human saphenous veins were cultured either under venous (flow: 5 ml/min) or arterial hemodynamic conditions (flow: 50 ml/min, pressure: 80 mmHg) for 1-, 2- and 4-day periods. Cell viability, cell density and apoptosis were compared before and after these intervals using MTT, Hoeschst 33258 stain, and TUNEL assays, respectively. RESULTS Fresh excised tissue segments were well preserved prior to the study. Hoechst 33258 and MTT stains showed progressive losses in cell density and cell viability in veins cultured under arterial hemodynamic conditions from 1 to 4 days, while no alterations were observed in veins cultured under venous conditions. Although the cell density from 1-day cultured veins under arterial conditions was similar to that of freshly excised veins, the TUNEL assay indicated that most of these cells were undergoing apoptosis. CONCLUSION The results observed resemble the events taking place during early in vivo arterial-vein grafting and provide evidence that an ex vivo perfusion system may be useful for the identification of new therapeutic targets that ameliorate vein graft remodeling and increase graft patency over time.
Collapse
Affiliation(s)
- Ayumi Aurea Miyakawa
- Heart Institute (InCor) and Department of Medicine-LIM 13, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brazil.
| | | | | | | | | |
Collapse
|
27
|
Wayman BH, Taylor WR, Rachev A, Vito RP. Arteries respond to independent control of circumferential and shear stress in organ culture. Ann Biomed Eng 2008; 36:673-84. [PMID: 18228146 DOI: 10.1007/s10439-008-9435-x] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2007] [Accepted: 01/08/2008] [Indexed: 11/24/2022]
Abstract
Arteries respond to changes in global mechanical parameters (pressure, flow rate, and longitudinal stretching) by remodeling to restore local parameters (circumferential stress, shear stress, and axial strain) to baseline levels. Because a change in a single global parameter results in changes of multiple local parameters, the effects of individual local parameters on remodeling remain unknown. This study uses a novel approach to study remodeling in organ culture based on independent control of local mechanical parameters. The approach is illustrated by studying the short term effects of circumferential and shear stress on remodeling-related biological markers. Porcine carotid arteries were cultured for 3 days at a circumferential stress of 50 or 150 kPa or, in separate experiments, a shear stress of 0.75 or 2.25 Pa. At high circumferential stress, matrix synthesis, smooth muscle cell proliferation, and cell death are significantly greater, but matrix metalloproteinase-2 (MMP-2) and pro-MMP-2 activity are significantly less. In contrast, biological markers measured were unaffected by shear stress. Applications of the proposed approach for improved understanding of remodeling, optimizing mechanical conditioning of tissue engineered arteries, and selection of experimentally motivated growth laws are discussed.
Collapse
Affiliation(s)
- Brian H Wayman
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, 315 Ferst Drive, Atlanta, GA 30332, USA
| | | | | | | |
Collapse
|
28
|
Nichol JW, Petko M, Myung RJ, Gaynor JW, Gooch KJ. Hemodynamic conditions alter axial and circumferential remodeling of arteries engineered ex vivo. Ann Biomed Eng 2005; 33:721-32. [PMID: 16078612 DOI: 10.1007/s10439-005-4494-8] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
We previously demonstrated that growth and remodeling was stimulated in arteries elongated ex vivo using step increases in axial strain. Viability and vasoactivity were similar to fresh arteries, however there was a substantial decrease in the ultimate circumferential stress. To test the hypothesis that the subphysiological perfusion conditions (i.e., low pressure and flow) previously used caused the reduction, arteries were subjected to the identical elongation protocol (50% increase over 9 days) while being perfused with physiological levels of flow, viscosity and pulsatile pressure. A significant increase in unloaded length was achieved by elongation under both perfusion conditions, although the increase was less under physiological (7 +/- 1%) than under subphysiological conditions (19 +/- 2%, p < 0.005). When length at physiological stress was estimated using mechanical testing data the values were similar. The ultimate circumferential stress of arteries elongated under physiological conditions was increased (33%), whereas the ultimate axial stress was decreased (50%) as compared with arteries elongated under subphysiological conditions. Elongated arteries under both perfusion conditions showed significant increases in proliferation and collagen mass, and similar viability and appearance to fresh arteries. These data suggest that there is substantial cross-talk between perfusion conditions and axial strain that modulates arterial remodeling and length.
Collapse
Affiliation(s)
- Jason W Nichol
- Department of Bioengineering, Institute for Medicine and Engineering, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | | | | | | | | |
Collapse
|
29
|
Davis NP, Han HC, Wayman B, Vito R. Sustained axial loading lengthens arteries in organ culture. Ann Biomed Eng 2005; 33:867-77. [PMID: 16060526 DOI: 10.1007/s10439-005-3488-x] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Although it has been recognized for many years that arteries in vivo exist under significant axial strain, studies of the adaptation of arteries to elevated axial strain have only recently been conducted. To determine the effects of sustained elevation of axial loading on arterial structure and function, axial stresses of 250 kPa or greater were applied to porcine common carotid arteries maintained in a perfusion organ culture system for 7 days at physiologic pressure and flow conditions. Our results demonstrated that axial stretch could lead to an increase in unloaded length that was proportional to the axial stretch ratio (stretched length divided by unloaded length) when the axial stretch ratio was above a threshold value of 2.14. Below this threshold, no significant length change occurred. Above this threshold, a significant increase in unloaded length (13 +/- 7%,) and the number of smooth muscle cell nuclei (20 +/- 7%) was observed. Permanent length change was associated with a significant decrease in axial stiffness, and the maximum elongation achieved was limited by rupture of the arterial wall. All tested arteries demonstrated good viability and strong vasomotor responses. These results show that arteries in organ culture can elongate under sustained axial loading.
Collapse
Affiliation(s)
- N Peter Davis
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA.
| | | | | | | |
Collapse
|
30
|
Changes of opening angle in hypertensive and hypotensive arteries in 3-day organ culture. J Biomech 2005; 39:2410-8. [PMID: 16174520 DOI: 10.1016/j.jbiomech.2005.08.003] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2005] [Accepted: 08/01/2005] [Indexed: 11/22/2022]
Abstract
To study the effect of pressure changes on the opening angle of arteries in organ culture, tubular segments of porcine common carotid arteries were cultured with pulsatile flow perfusion under hypertensive (150+/-20 mmHg), normotensive (100+/-20 mmHg), or hypotensive (30+/-10 mmHg) pressure while maintaining the arteris at a physiological wall shear stress of approximately 15 dyn/cm(2) for up to 3 days. Arteries were then cut into short ring segments by sections perpendicular to the axis and then cut open radially to observe the opening angle in aerated phosphate buffered saline solution (37 degrees C). Norepinephrine (NE, 10 microM), carbacol (CCh, 100 microM), and sodium nitroprusside (SNP, 10 microM) were added after the radial cut at 30, 20, and 30 min intervals, the opening angles were measured, respectively. Results show that hypertensive arteries developed a significantly larger opening angle than normotensive and hypotensive arteries, associated with a significant increase in cell proliferation. In addition, with smooth muscle contraction activated by NE, the opening angle decreases significantly in hypertensive arteries but has little change in hypotensive and normotensive arteries, indicating an enhancement of smooth muscle contraction on the lumen side of the hypertensive arterial wall. In comparison, hypotensive pressure has little effect on arterial opening angle and cell proliferation.
Collapse
|
31
|
Gleason RL, Gray SP, Wilson E, Humphrey JD. A multiaxial computer-controlled organ culture and biomechanical device for mouse carotid arteries. J Biomech Eng 2005; 126:787-95. [PMID: 15796337 DOI: 10.1115/1.1824130] [Citation(s) in RCA: 123] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Much of our understanding of vascular mechanotransduction has come from studies using either cell culture or in vivo animal models, but the recent success of organ culture systems offers an exciting alternative. In studying cell-mediated vascular adaptations to altered loading, organ culture allows one to impose well-controlled mechanical loads and to perform multiaxial mechanical tests on the same vessel throughout the culture period, and thereby to observe cell-mediated vascular adaptations independent of neural and hormonal effects. Here, we present a computer-controlled perfused organ culture and biomechanical testing device designed for small caliber (50-5000 micron) blood vessels. This device can control precisely the pulsatile pressure, luminal flow, and axial load (or stretch) and perform intermittent biaxial (pressure-diameter and axial load-length) and functional tests to quantify adaptations in mechanical behavior and cellular function, respectively. Device capabilities are demonstrated by culturing mouse carotid arteries for 4 days.
Collapse
Affiliation(s)
- R L Gleason
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | | | | | | |
Collapse
|
32
|
Abstract
A conspicuous long-term consequence of hypertension is a thickening of the arterial wall, which many suggest returns the circumferential wall stress toward its normal value. This thickening results from an increase in smooth muscle and extracellular matrix, with the associated growth and remodeling processes depending on a host of regulatory signals that likely include the altered mechanical environment. Although the precise mechanotransduction pathways remain unknown, we propose that vasoconstriction may be an early response of the arterial wall to a step-change in pressure. In particular, computations suggest that such a response can decrease the magnitude and transmural gradients of the pressure-induced wall stresses and return the mean wall shear stress toward its homeostatic value. Such an initial 'compensatory vasoconstriction' could also help set into motion subsequent growth and remodeling responses due to growth regulatory characteristics of the vasoactive molecules (e.g., nitric oxide, endothelin-1, angiotensin-II). Although the consequences of growth and remodeling have been the focus of prior biomechanical and histological studies, early responses dictate subsequent developments and therefore deserve increased attention in vascular biomechanics and mechanobiology.
Collapse
Affiliation(s)
- Jay D Humphrey
- Department of Biomedical Engineering and M.E. DeBakey Institute, Texas A&M University, 233 Zachry Engineering Center, College Station, TX 77843-3120, USA.
| | | |
Collapse
|