1
|
Setliff JC, Anderst WJ. A scoping review of human skeletal kinematics research using biplane radiography. J Orthop Res 2024; 42:915-922. [PMID: 38366965 DOI: 10.1002/jor.25806] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 10/18/2023] [Accepted: 12/12/2023] [Indexed: 02/19/2024]
Abstract
Biplane radiography has emerged as the gold standard for accurately measuring in vivo skeletal kinematics during physiological loading. The purpose of this scoping review was to map the extent, range, and nature of biplane radiography research on humans from 2004 through 2022. A literature search was performed using the terms biplane radiography, dual fluoroscopy, dynamic stereo X-ray, and biplane videoradiography. All articles referenced in included publications were also assessed for inclusion. A secondary search was then performed using the names of the most frequently appearing principal investigators among included papers. A total of 379 manuscripts were identified and included. The first studies published in 2004 focused on the native knee, followed by studies of the ankle joint complex in 2006, the shoulder in 2007, and the spine in 2008. Nearly half (180, 47.5%) of all manuscripts investigated knee kinematics. The average number of publications increased from 21.6 per year from 2012 to 2017 to 34.6 per year from 2017 to 2022. The average number of participants per study was 16, with a range from 1 to 101. A total of 90.2% of studies featured cohorts of 30 or less. The most prolific research groups for each joint were: Mass General Hospital (lumbar spine and knee), Henry Ford Hospital (shoulder), the University of Utah (ankle and hip), The University of Pittsburgh (cervical spine), and Brown University (hand/wrist/elbow). Future advancements in biplane radiography research are dependent upon increased availability of these imaging systems, standardization of data collection protocols, and the development of automated approaches to expedite data processing.
Collapse
Affiliation(s)
- Joshua C Setliff
- Biodynamics Lab, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | - William J Anderst
- Biodynamics Lab, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| |
Collapse
|
2
|
Maikos JT, Chomack JM, Herlihy DV, Paglia DN, Wetterstrand C, O'Connor JP, Hyre MJ, Loan JP, D'Andrea SE. Quantifying Bone and Skin Movement in the Residual Limb-Socket Interface of Individuals With Transtibial Limb Loss Using Dynamic Stereo X-Ray: Protocol for a Lower Limb Loss Cadaver and Clinical Study. JMIR Res Protoc 2024; 13:e57329. [PMID: 38669065 PMCID: PMC11087852 DOI: 10.2196/57329] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Revised: 02/29/2024] [Accepted: 03/04/2024] [Indexed: 04/28/2024] Open
Abstract
BACKGROUND Relative motion between the residual limb and socket in individuals with transtibial limb loss can lead to substantial consequences that limit mobility. Although assessments of the relative motion between the residual limb and socket have been performed, there remains a substantial gap in understanding the complex mechanics of the residual limb-socket interface during dynamic activities that limits the ability to improve socket design. However, dynamic stereo x-ray (DSX) is an advanced imaging technology that can quantify 3D bone movement and skin deformation inside a socket during dynamic activities. OBJECTIVE This study aims to develop analytical tools using DSX to quantify the dynamic, in vivo kinematics between the residual limb and socket and the mechanism of residual tissue deformation. METHODS A lower limb cadaver study will first be performed to optimize the placement of an array of radiopaque beads and markers on the socket, liner, and skin to simultaneously assess dynamic tibial movement and residual tissue and liner deformation. Five cadaver limbs will be used in an iterative process to develop an optimal marker setup. Stance phase gait will be simulated during each session to induce bone movement and skin and liner deformation. The number, shape, size, and placement of each marker will be evaluated after each session to refine the marker set. Once an optimal marker setup is identified, 21 participants with transtibial limb loss will be fitted with a socket capable of being suspended via both elevated vacuum and traditional suction. Participants will undergo a 4-week acclimation period and then be tested in the DSX system to track tibial, skin, and liner motion under both suspension techniques during 3 activities: treadmill walking at a self-selected speed, at a walking speed 10% faster, and during a step-down movement. The performance of the 2 suspension techniques will be evaluated by quantifying the 3D bone movement of the residual tibia with respect to the socket and quantifying liner and skin deformation at the socket-residuum interface. RESULTS This study was funded in October 2021. Cadaver testing began in January 2023. Enrollment began in February 2024. Data collection is expected to conclude in December 2025. The initial dissemination of results is expected in November 2026. CONCLUSIONS The successful completion of this study will help develop analytical methods for the accurate assessment of residual limb-socket motion. The results will significantly advance the understanding of the complex biomechanical interactions between the residual limb and the socket, which can aid in evidence-based clinical practice and socket prescription guidelines. This critical foundational information can aid in the development of future socket technology that has the potential to reduce secondary comorbidities that result from complications of poor prosthesis load transmission. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID) DERR1-10.2196/57329.
Collapse
Affiliation(s)
- Jason T Maikos
- Veterans Affairs New York Harbor Healthcare System, New York, NY, United States
| | - John M Chomack
- Veterans Affairs New York Harbor Healthcare System, New York, NY, United States
| | - David V Herlihy
- Narrows Institute for Biomedical Research and Education, Inc., Brooklyn, NY, United States
| | - David N Paglia
- Department of Orthopaedics, Rutgers-New Jersey Medical School, Newark, NJ, United States
| | - Charlene Wetterstrand
- Department of Orthopaedics, Rutgers-New Jersey Medical School, Newark, NJ, United States
| | - J Patrick O'Connor
- Department of Orthopaedics, Rutgers-New Jersey Medical School, Newark, NJ, United States
| | - Michael J Hyre
- Narrows Institute for Biomedical Research and Education, Inc., Brooklyn, NY, United States
| | | | - Susan E D'Andrea
- Department of Kinesiology, College of Health Sciences, University of Rhode Island, Kingston, RI, United States
| |
Collapse
|
3
|
Park J, Kim DS, Huh H, Cho WG, Kim H, Lee DW. In Vivo 3-Dimensional Dynamic Evaluation of Shoulder Kinematics After the Latarjet Procedure: Comparison With the Contralateral Healthy Shoulder. Orthop J Sports Med 2024; 12:23259671241226909. [PMID: 38486807 PMCID: PMC10938626 DOI: 10.1177/23259671241226909] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Accepted: 08/18/2023] [Indexed: 03/17/2024] Open
Abstract
Background Researchers have attempted to understand the underlying mechanism of the Latarjet procedure; however, its effects on shoulder kinematics have not been well studied. Purpose/Hypothesis The purpose was to analyze shoulder kinematics after the Latarjet procedure. It was hypothesized that the nonanatomic transfer of the coracoid process during the procedure would affect normal shoulder kinematics. Study Design Controlled laboratory study. Methods The study included 10 patients (age range, 20-52 years) who underwent the modified Latarjet procedure between June 2016 and November 2021. Computed tomography and fluoroscopy were conducted on both shoulder joints of all patients, and 3-dimensional models were reconstructed. The 3-dimensional coordinates were encoded on the reconstructed models, and shoulder kinematics were analyzed through a 3-dimensional-2-dimensional model-image registration technique. Scapular rotation parameters (scapular upward rotation, posterior tilt, external rotation, and scapulohumeral rhythm) were compared between the Latarjet and the nonsurgical contralateral sides during humeral abduction, as was anteroposterior (AP) translation relative to the glenoid center during active humeral external rotation. Results The Latarjet side displayed significantly higher values of scapular upward rotation at higher degrees of humeral elevation (130°, 140°, and 150°) compared with the nonsurgical side (P = .027). Posterior tilt, external rotation, and scapulohumeral rhythm were not significantly different between sides. AP translation at maximal humeral rotation was not significantly different between sides (Latarjet, -0.06 ± 5.73 mm vs nonsurgical, 5.33 ± 1.60 mm; P = .28). Interestingly, on the Latarjet side, AP translation increased until 40° of humeral rotation (4.27 ± 4.64 mm) but began to decrease from 50° of humeral rotation. Conclusion The Latarjet side demonstrated significant changes in scapular upward rotation during higher degrees of humeral elevation compared with the contralateral shoulder. Posterior movement of the humeral head at >50° of humeral rotation could be the desired effect of anterior stabilization; however, researchers should evaluate long-term complications such as osteoarthritis. Clinical Relevance Analysis of shoulder kinematics after the Latarjet procedure could provide information regarding long-term outcomes and whether the procedure would affect the daily activities of patients.
Collapse
Affiliation(s)
- Jisu Park
- Department of Orthopedic Surgery, Wonju College of Medicine, Yonsei University, Republic of Korea
| | - Doo Sup Kim
- Department of Orthopedic Surgery, Wonju College of Medicine, Yonsei University, Republic of Korea
| | - Hyungkyu Huh
- Daegu-Gyeongbuk Medical Innovation Foundation, Dae-gu, Republic of Korea
| | - Won Gil Cho
- Department of Anatomy, Wonju College of Medicine, Yonsei University, Gangwon-do, Republic of Korea
| | - HyunWoo Kim
- Department of Orthopedic Surgery, Wonju College of Medicine, Yonsei University, Republic of Korea
| | - Dong-Woo Lee
- Department of Orthopaedics, Hanil General Hospital, Seoul, Republic of Korea
| |
Collapse
|
4
|
Mattar LT, Johnson CC, Gale TH, Popchak AJ, Anderst WJ, Musahl V, Irrgang JJ, Debski RE. Improved joint function when reaching behind the back is associated with patient reported outcomes in individuals with rotator cuff tears following exercise therapy. Clin Biomech (Bristol, Avon) 2024; 112:106184. [PMID: 38244237 PMCID: PMC10922910 DOI: 10.1016/j.clinbiomech.2024.106184] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Revised: 01/08/2024] [Accepted: 01/11/2024] [Indexed: 01/22/2024]
Abstract
BACKGROUND Reaching behind the back is painful for individuals with rotator cuff tears. The objectives of the study were to determine changes in glenohumeral kinematics when reaching behind the back, passive range of motion (RoM), patient reported outcomes and the relationships between kinematics and patient reported outcomes following exercise therapy. METHODS Eighty-four individuals with symptomatic isolated supraspinatus tears were recruited for this prospective observational study. Glenohumeral kinematics were measured using biplane radiography during a reaching behind the back movement. Passive glenohumeral internal rotation and patient reported outcome measures were collected. Depending on data normality, appropriate tests were utilized to determine changes in variables. Spearman's correlations were utilized for associations, and Stuart-Maxwell tests for changes in distributions. FINDINGS Maximum active glenohumeral internal rotation increased by 3.2° (P = 0.001), contact path length decreased by 5.5% glenoid size (P = 0.022), passive glenohumeral internal rotation RoM increased by 4.9° (P = 0.001), and Western Ontario Rotator Cuff Index and American Shoulder and Elbow Surgeons scores increased by 29.8 and 21.1 (P = 0.001), respectively. Changes in Western Ontario Rotator Cuff Index scores positively associated with changes in maximum active glenohumeral internal rotation and negatively associated with changes in contact path lengths (P = 0.008 and P = 0.006, respectively). INTERPRETATION The reaching behind the back movement was useful in elucidating in-vivo mechanistic changes associated with patient reported outcomes. Glenohumeral joint function and patient reported outcomes improved, where changes in Western Ontario Rotator Cuff Index scores were associated with kinematics. These findings inform clinicians of functional changes following exercise therapy and new targetable treatment factors.
Collapse
Affiliation(s)
- Luke T Mattar
- Orthopaedic Robotics Laboratory, University of Pittsburgh, Pittsburgh, PA, United States; UPMC Freddie Fu Sports Medicine Center, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA, United States.
| | - Camille C Johnson
- Biodynamics Laboratory, University of Pittsburgh, Pittsburgh, PA, United States; Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, PA, United States.
| | - Tom H Gale
- Biodynamics Laboratory, University of Pittsburgh, Pittsburgh, PA, United States; UPMC Freddie Fu Sports Medicine Center, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA, United States.
| | - Adam J Popchak
- Department of Physical Therapy, University of Pittsburgh, Pittsburgh, PA, United States.
| | - William J Anderst
- Biodynamics Laboratory, University of Pittsburgh, Pittsburgh, PA, United States; UPMC Freddie Fu Sports Medicine Center, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA, United States.
| | - Volker Musahl
- Orthopaedic Robotics Laboratory, University of Pittsburgh, Pittsburgh, PA, United States; Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, PA, United States; UPMC Freddie Fu Sports Medicine Center, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA, United States.
| | - James J Irrgang
- UPMC Freddie Fu Sports Medicine Center, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA, United States; Department of Physical Therapy, University of Pittsburgh, Pittsburgh, PA, United States.
| | - Richard E Debski
- Orthopaedic Robotics Laboratory, University of Pittsburgh, Pittsburgh, PA, United States; Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, PA, United States; UPMC Freddie Fu Sports Medicine Center, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA, United States.
| |
Collapse
|
5
|
Andro C, Garraud C, Deransart P, Stindel E, Letissier H, Dardenne G. Orientation of the Scapula in the Standing Position. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2024; 43:375-383. [PMID: 37987527 DOI: 10.1002/jum.16370] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 10/15/2023] [Accepted: 10/22/2023] [Indexed: 11/22/2023]
Abstract
OBJECTIVES A new ultrasound-based device is proposed to non-invasively measure the orientation of the scapula in the standing position to consider this parameter for Total Shoulder Arthroplasty. The aim of this study was to assess the accuracy and reliability of this device. METHODS Accuracy was assessed by comparing measurements made with the ultrasound device to those acquired with a three-dimensional (3D) optical localization system (Northern Digital, Canada) on a dedicated mechanical phantom. Three users performed 10 measurements on three healthy volunteers with different body mass (BMI) indices to analyze the reliability of the device by measuring the intra and interobserver variabilities. RESULTS The mean accuracy of the device was 0.9°± 0.7 (0.01-3.03), 1.3°± 0.8 (0.03-4.55), 1.9°± 1.5 (0.05-5.76), respectively, in the axial, coronal, and sagittal planes. The interobserver and intraobserver variabilities were excellent whatever the BMI and the users experience. CONCLUSIONS The device is accurate and reliable enough for the measurement of the scapula orientation in the standing position.
Collapse
Affiliation(s)
- Christophe Andro
- LaTIM, Inserm, Brest, France
- Hôpital d'Instruction des Armées Clermont, Brest, France
| | | | | | - Eric Stindel
- LaTIM, Inserm, Brest, France
- CHU Brest, Brest, France
- Université de Bretagne Occidentale (UBO), Brest, France
| | - Hoel Letissier
- LaTIM, Inserm, Brest, France
- CHU Brest, Brest, France
- Université de Bretagne Occidentale (UBO), Brest, France
| | | |
Collapse
|
6
|
Mattar LT, Mahboobin AB, Popchak AJ, Anderst WJ, Musahl V, Irrgang JJ, Debski RE. Individuals with rotator cuff tears unsuccessfully treated with exercise therapy have less inferiorly oriented net muscle forces during scapular plane abduction. J Biomech 2024; 162:111859. [PMID: 37989027 PMCID: PMC10843663 DOI: 10.1016/j.jbiomech.2023.111859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 09/29/2023] [Accepted: 11/03/2023] [Indexed: 11/23/2023]
Abstract
Exercise therapy for individuals with rotator cuff tears fails in approximately 25.0 % of cases. One reason for failure of exercise therapy may be the inability to strengthen and balance the muscle forces crossing the glenohumeral joint that act to center the humeral head on the glenoid. The objective of the current study was to compare the magnitude and orientation of the net muscle force pre- and post-exercise therapy between subjects successfully and unsuccessfully (e.g. eventually underwent surgery) treated with a 12-week individualized exercise therapy program. Twelve computational musculoskeletal models (n = 6 successful, n = 6 unsuccessful) were developed in OpenSim (v4.0) that incorporated subject specific tear characteristics, muscle peak isometric force, in-vivo kinematics and bony morphology. The models were driven with experimental kinematics and the magnitude and orientation of the net muscle force was determined during scapular plane abduction at pre- and post-exercise therapy timepoints. Subjects unsuccessfully treated had less inferiorly oriented net muscle forces pre- and post-exercise therapy compared to subjects successfully treated (p = 0.039 & 0.045, respectively). No differences were observed in the magnitude of the net muscle force (p > 0.05). The current study developed novel computational musculoskeletal models with subject specific inputs capable of distinguishing between subjects successfully and unsuccessfully treated with exercise therapy. A less inferiorly oriented net muscle force in subjects unsuccessfully treated may increase the risk of superior migration leading to impingement. Adjustments to exercise therapy programs may be warranted to avoid surgery in subjects at risk of unsuccessful treatment.
Collapse
Affiliation(s)
- Luke T Mattar
- Orthopaedic Robotics Laboratory, University of Pittsburgh, United States; UPMC Freddie Fu Sports Medicine Center, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, United States
| | - Arash B Mahboobin
- Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, United States
| | - Adam J Popchak
- Department of Physical Therapy, University of Pittsburgh, Pittsburgh, United States
| | - William J Anderst
- Biodynamics Laboratory, University of Pittsburgh, United States; UPMC Freddie Fu Sports Medicine Center, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, United States
| | - Volker Musahl
- Orthopaedic Robotics Laboratory, University of Pittsburgh, United States; Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, United States; UPMC Freddie Fu Sports Medicine Center, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, United States
| | - James J Irrgang
- UPMC Freddie Fu Sports Medicine Center, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, United States; Department of Physical Therapy, University of Pittsburgh, Pittsburgh, United States
| | - Richard E Debski
- Orthopaedic Robotics Laboratory, University of Pittsburgh, United States; Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, United States; UPMC Freddie Fu Sports Medicine Center, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, United States.
| |
Collapse
|
7
|
Cyrus Rezvanifar S, Lamb JJ, Wing MF, Ellingson AM, Braman JP, Ludewig PM, Barocas VH. The long head of the biceps tendon undergoes multiaxial deformation during shoulder motion. J Biomech 2024; 162:111900. [PMID: 38104381 DOI: 10.1016/j.jbiomech.2023.111900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 12/04/2023] [Accepted: 12/07/2023] [Indexed: 12/19/2023]
Abstract
The long head biceps tendon (LHBT) is presumed a common source of shoulder joint pain and injury. Despite common LHBT pathologies, diagnosis and preferred treatment remain frequently debated. This Short Communication reports the development of a subject-specific finite element model of the shoulder joint based on one subject's 3D reconstructed anatomy and 3D in vivo kinematics recorded from bone-fixed electromagnetic sensors. The primary purpose of this study was to use the developed finite element model to investigate the LHBT mechanical environment during a typical shoulder motion of arm raising. Furthermore, this study aimed to assess the viability of material models derived from uniaxial tensile tests for accurate simulation of in vivo motion. The findings of our simulations indicate that the LHBT undergoes complex multidimensional deformations. As such, uniaxial material properties reported in the existing body of literature are not sufficient to simulate accurately the in vivo mechanical behavior of the LHBT. Further experimental tests on cadaveric specimens, such as biaxial tension and combinations of tension and torsion, are needed to describe fully the mechanical behavior of the LHBT and investigate its mechanisms of injury.
Collapse
Affiliation(s)
- S Cyrus Rezvanifar
- Division of Physical Therapy and Rehabilitation Science, University of Minnesota, Twin Cities, Minneapolis, MN 55455, USA
| | - J J Lamb
- Department of Mechanical Engineering University of Minnesota, Twin Cities, Minneapolis, MN 55455, USA
| | - Miles F Wing
- Department of Biomedical Engineering, University of Minnesota, Twin Cities, Minneapolis, MN 55455, USA
| | - Arin M Ellingson
- Division of Physical Therapy and Rehabilitation Science, University of Minnesota, Twin Cities, Minneapolis, MN 55455, USA
| | - Jonathan P Braman
- Department of Orthopedic Surgery University of Minnesota, Twin Cities, Minneapolis, MN 55455, USA; Chair of Orthopedic Surgery, Henry Ford Health, Detroit, MI 48202, USA
| | - Paula M Ludewig
- Division of Physical Therapy and Rehabilitation Science, University of Minnesota, Twin Cities, Minneapolis, MN 55455, USA.
| | - Victor H Barocas
- Department of Biomedical Engineering, University of Minnesota, Twin Cities, Minneapolis, MN 55455, USA
| |
Collapse
|
8
|
Boulanger SM, Mahna A, Alenabi T, Gatti AA, Culig O, Hynes LM, Chopp-Hurley JN. Investigating the reliability and validity of subacromial space measurements using ultrasound and MRI. J Orthop Surg Res 2023; 18:986. [PMID: 38135882 PMCID: PMC10740303 DOI: 10.1186/s13018-023-04482-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Accepted: 12/15/2023] [Indexed: 12/24/2023] Open
Abstract
BACKGROUND While ultrasound (US) measures of the subacromial space (SAS) have demonstrated excellent reliability, measurements are typically captured by experts with extensive ultrasound experience. Further, the agreement between US measured SAS width and other imaging modalities has not been explored. This research evaluated the agreement between SAS measures captured by novice and expert raters and between US and magnetic resonance imaging (MRI). This study also evaluated the effect of US transducer tilt on measured SAS. METHODS Nine men and nine women participated in this study. US images were captured by a novice and expert with the participant in both seated and supine positions. An inclinometer was fixed to the US probe to measure transducer tilt. SAS width was measured in real time from freeze framed images. MRI images were captured, and the humerus and acromion manually segmented. The SAS width was measured using a custom algorithm. RESULTS Intraclass correlation coefficients (ICCs) between novice and expert raters were 0.74 and 0.63 for seated and supine positions, respectively. Intra-rater agreement was high for both novice (ICC = 0.83-0.84) and expert (ICC ≥ 0.94) raters. Agreement between US and MRI was poor (ICC = 0.21-0.49) but linearly related. CONCLUSIONS Moderate agreement between novice and expert raters was demonstrated, while the agreement between US and MRI was poor. High intra-rater reliability within each rater suggests that US measures of the SAS may be completed by a novice with introductory training.
Collapse
Affiliation(s)
- Stephen M Boulanger
- School of Kinesiology and Health Science, York University, 4700 Keele Street, Toronto, ON, M3J 1P3, Canada
| | - Alexandra Mahna
- School of Kinesiology and Health Science, York University, 4700 Keele Street, Toronto, ON, M3J 1P3, Canada
| | - Talia Alenabi
- Department of Kinesiology, University of Waterloo, Waterloo, ON, Canada
| | - Anthony A Gatti
- Department of Radiology, Stanford University, Stanford, CA, USA
- NeuralSeg Ltd., Hamilton, ON, Canada
| | - Oriana Culig
- School of Kinesiology and Health Science, York University, 4700 Keele Street, Toronto, ON, M3J 1P3, Canada
| | - Loriann M Hynes
- School of Kinesiology and Health Science, York University, 4700 Keele Street, Toronto, ON, M3J 1P3, Canada
| | - Jaclyn N Chopp-Hurley
- School of Kinesiology and Health Science, York University, 4700 Keele Street, Toronto, ON, M3J 1P3, Canada.
| |
Collapse
|
9
|
Oyekan AA, LeVasseur CM, Chen SR, Padmanabhan A, Makowicz N, Donaldson WF, Lee JY, Shaw JD, Anderst WJ. The Effects of Cervical Orthoses on Head and Intervertebral Range of Motion. Spine (Phila Pa 1976) 2023; 48:1561-1567. [PMID: 37339257 DOI: 10.1097/brs.0000000000004755] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Accepted: 06/02/2023] [Indexed: 06/22/2023]
Abstract
STUDY DESIGN Prospective Cohort. OBJECTIVE Quantify and compare the effectiveness of cervical orthoses in restricting intervertebral kinematics during multiplanar motions. SUMMARY OF BACKGROUND DATA Previous studies evaluating the efficacy of cervical orthoses measured global head motion and did not evaluate individual cervical motion segment mobility. Prior studies focused only on the flexion/extension motion. METHODS Twenty adults without neck pain participated. Vertebral motion from the occiput through T1 was imaged using dynamic biplane radiography. Intervertebral motion was measured using an automated registration process with validated accuracy better than 1 degree. Participants performed independent trials of maximal flexion/extension, axial rotation, and lateral bending in a randomized order of unbraced, soft collar (foam), hard collar (Aspen), and cervical thoracic orthosis (CTO) (Aspen) conditions. Repeated-measures ANOVA was used to identify differences in the range of motion (ROM) among brace conditions for each motion. RESULTS Compared with no collar, the soft collar reduced flexion/extension ROM from occiput/C1 through C4/C5, and reduced axial rotation ROM at C1/C2 and from C3/C4 through C5/C6. The soft collar did not reduce motion at any motion segment during lateral bending. Compared with the soft collar, the hard collar reduced intervertebral motion at every motion segment during all motions, except for occiput/C1 during axial rotation and C1/C2 during lateral bending. The CTO reduced motion compared with the hard collar only at C6/C7 during flexion/extension and lateral bending. CONCLUSIONS The soft collar was ineffective as a restraint to intervertebral motion during lateral bending, but it did reduce intervertebral motion during flexion/extension and axial rotation. The hard collar reduced intervertebral motion compared with the soft collar across all motion directions. The CTO provided a minimal reduction in intervertebral motion compared with the hard collar. The utility in using a CTO rather than a hard collar is questionable, given the cost and little or no additional motion restriction.
Collapse
Affiliation(s)
- Anthony A Oyekan
- Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA
| | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Ikebe S, Shimoto T, Higaki H, Banks SA. DRR acceleration using inexpensive GPUs for model-image registration based joint kinematic measurements. J Biomech 2023; 160:111824. [PMID: 37862924 DOI: 10.1016/j.jbiomech.2023.111824] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Revised: 08/30/2023] [Accepted: 10/03/2023] [Indexed: 10/22/2023]
Abstract
Model-image registration methods are commonly used in research to measure three-dimensional joint kinematics from single-plane and bi-plane x-ray images. These methods have the potential to be beneficial if used clinically, but current techniques are too slow or expensive to be clinically practical. One technical element of these methods for measuring natural bone motion is the use of digitally reconstructed radiographs (DRRs). DRRs can be very expensive to compute, or require expensive and fast computer hardware. In this technical development, a numerically efficient Siddon-Jacobs algorithm for computing DRRs was implemented on a consumer-grade graphics card using a programming language for parallel architectures. Compared to traditional voxel projection algorithms with a central-processing-unit-only implementation, the parallel computation implementation on the graphics card provided speedups of 650-1546 times faster rendering, while retaining equivalent performance for joint kinematics measurements. The use of consumer grade graphics hardware may contribute to making model-image registration measurements of joint kinematics practical for clinical use.
Collapse
Affiliation(s)
- Satoru Ikebe
- National Institute of Technology, Kitakyushu College, Kitakyushu, Fukuoka, Japan; University of Florida, Gainesville, FL, USA.
| | | | | | | |
Collapse
|
11
|
Sulkar HJ, Aliaj K, Tashjian RZ, Chalmers PN, Foreman KB, Henninger HB. High and low performers in internal rotation after reverse total shoulder arthroplasty: a biplane fluoroscopic study. J Shoulder Elbow Surg 2023; 32:e133-e144. [PMID: 36343789 PMCID: PMC10023281 DOI: 10.1016/j.jse.2022.10.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Revised: 09/25/2022] [Accepted: 10/04/2022] [Indexed: 11/06/2022]
Abstract
BACKGROUND Internal rotation in adduction is often limited after reverse total shoulder arthroplasty (rTSA), but the origins of this functional deficit are unclear. Few studies have directly compared individuals who can and cannot perform internal rotation in adduction. Little data on underlying 3D humerothoracic, scapulothoracic, and glenohumeral joint relationships in these patients are available. METHODS Individuals >1-year postoperative to rTSA were imaged with biplane fluoroscopy in resting neutral and internal rotation in adduction poses. Subjects could either perform internal rotation in adduction with their hand at T12 or higher (high, N = 7), or below the hip pocket (low, N = 8). Demographics, the American Shoulder and Elbow Surgeons score, Simple Shoulder Test, and scapular notching grade were recorded. Joint orientation angles were derived from model-based markerless tracking of the scapula and humerus relative to the torso. The 3D implant models were aligned to preoperative computed tomography models to evaluate bone-implant impingement. RESULTS The Simple Shoulder Test was highest in the high group (11 ± 1 vs. 9 ± 2, P = .019). Two subjects per group had scapular notching (grades 1 and 2), and 3 high group and 4 low group subjects had impingement below the glenoid. In the neutral pose, the scapula had 7° more upward rotation in the high group (P = .100), and the low group demonstrated 9° more posterior tilt (P = .017) and 14° more glenohumeral elevation (P = .047). In the internal rotation pose, axial rotation was >45° higher in the high group (P ≤ .008) and the low group again had 11° more glenohumeral elevation (P = .058). Large rotational differences within subject groups arose from a combination of differences in the resting neutral and maximum internal rotation in adduction poses, not only the terminal arm position. CONCLUSIONS Individuals who were able to perform high internal rotation in adduction after rTSA demonstrated differences in joint orientation and anatomic biases versus patients with low internal rotation. The high rotation group had 7° more resting scapular upward rotation and used a 15°-30° change in scapular tilt to perform internal rotation in adduction versus patients in the low group. The combination of altered resting scapular posture and restricted scapulothoracic range of motion could prohibit glenohumeral rotation required to reach internal rotation in adduction. In addition, inter-patient variation in humeral torsion may contribute substantially to postoperative internal rotation differences. These data point toward modifiable implant design and placement factors, as well as foci for physical therapy to strengthen and mobilize the scapula and glenohumeral joint in response to rTSA surgery.
Collapse
Affiliation(s)
- Hema J Sulkar
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, USA; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA
| | - Klevis Aliaj
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, USA; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA
| | - Robert Z Tashjian
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, USA
| | - Peter N Chalmers
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, USA
| | - K Bo Foreman
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, USA; Department of Physical Therapy and Athletic Training, University of Utah, Salt Lake City, UT, USA
| | - Heath B Henninger
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, USA; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA.
| |
Collapse
|
12
|
Lawrence R, Soliman SB, Roseni K, Zauel R, Bey MJ. In vivo evaluation of rotator cuff internal impingement during scapular plane abduction in asymptomatic individuals. J Orthop Res 2023; 41:718-726. [PMID: 35880416 PMCID: PMC9877247 DOI: 10.1002/jor.25423] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 06/17/2022] [Accepted: 07/23/2022] [Indexed: 02/04/2023]
Abstract
Internal impingement-or entrapment of the undersurface of the rotator cuff tendon against the glenoid during overhead activities-is believed to contribute to articular-sided tears. However, little is known about internal impingement outside athletic populations. Therefore, the objectives of this study were to (1) describe glenoid-to-footprint distances and proximity centers during dynamic, in vivo motion in asymptomatic individuals, and (2) determine the extent to which these measures differed between individuals with and without a rotator cuff tear. Shoulder kinematics were assessed in 37 asymptomatic individuals during scapular plane abduction using a high-speed biplane radiographic system. Glenoid-to-footprint distances and proximity center locations were calculated by combining the kinematics with computerized tomography-derived bone models. Glenoid-to-footprint contact was presumed to occur when the minimum distance was less than the estimated labral thickness. The condition of the supraspinatus tendon (intact, torn) was assessed using ultrasound. Minimum distances and proximity centers were compared over humerothoracic elevation angles (90°, 110°, 130°, 150°) and between supraspinatus pathology groups using two-factor mixed model analysis of variances. Glenoid-to-footprint minimum distances decreased consistently across elevation angles (p < 0.01) without a significant difference between groups. Contact was estimated to occur in all participants. Proximity centers were generally located on the anterior half of the rotator cuff footprint and on the posterosuperior glenoid. Statement of Clinical Significance: Internal impingement during overhead motions may be a prevalent mechanism of rotator cuff pathology as contact appears to be common and involves the region of the rotator cuff footprint where degenerative rotator cuff tears are thought to originate.
Collapse
Affiliation(s)
| | | | - Kevin Roseni
- Bone & Joint Center, Henry Ford Health System, Detroit, MI
| | - Roger Zauel
- Bone & Joint Center, Henry Ford Health System, Detroit, MI
| | - Michael J Bey
- Bone & Joint Center, Henry Ford Health System, Detroit, MI
| |
Collapse
|
13
|
Ramsdell JC, Scott ME, Beynnon BD, Fiorentino NM. Does interpolation and intra-user variability affect the accuracy of arthrokinematic measurements in the knee? A dual fluoroscopic imaging and model-based tracking study. Med Eng Phys 2023; 114:103968. [PMID: 37030894 PMCID: PMC10115154 DOI: 10.1016/j.medengphy.2023.103968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 02/07/2023] [Accepted: 03/10/2023] [Indexed: 03/15/2023]
Abstract
Model-based tracking (MBT) is a time-consuming and semiautomatic approach, and thus subject to errors during the tracking process. The present study aimed primarily to quantify the effects that interpolation and intra-user variability associated with MBT have on the kinematic and arthrokinematic measurements in comparison to a gold standard radiostereometric analysis (RSA). Cadaveric knee specimens were imaged at 125 Hz while simulating standing, walking, jogging, and lunging motions. (Arthro)kinematic metrics were calculated via MBT without interpolation, MBT with two interpolation techniques when every fifth or tenth frame was analyzed, and RSA. Tracking the same activity multiple times affected (p-value, largest mean difference) the flexion-extension (FE) joint angle during walking (0.03, 0.6°), and the internal-external joint angle during jogging (0.048, -0.9°). Only during jogging for the FE joint angle was there an effect of interpolation (0.046, 0.3°). Neither tracking multiple times nor interpolation affected arthrokinematic metrics (contact path locations and excursions). The present study is the first to quantify the effects that intra-user variability and interpolation have on the (arthro)kinematic measurement accuracy using MBT. Results suggest interpolation may be used without sacrificing (arthro)kinematic outcome measurement accuracy and the errors associated with intra-user variability, while small, were larger than errors due to interpolation.
Collapse
Affiliation(s)
- John C Ramsdell
- Department of Electrical and Biomedical Engineering, University of Vermont, USA
| | - Marit E Scott
- Department of Electrical and Biomedical Engineering, University of Vermont, USA
| | - Bruce D Beynnon
- Department of Electrical and Biomedical Engineering, University of Vermont, USA; Department of Orthopaedics and Rehabilitation, University of Vermont
| | - Niccolo M Fiorentino
- Department of Electrical and Biomedical Engineering, University of Vermont, USA; Department of Orthopaedics and Rehabilitation, University of Vermont; Department of Mechanical Engineering, University of Vermont.
| |
Collapse
|
14
|
Tang Y, Hao D, Cao C, Shi P, Yu H, Luan X, Fang F. Glenohumeral joint trajectory tracking for improving the shoulder compliance of the upper limb rehabilitation robot. Med Eng Phys 2023; 113:103961. [PMID: 36966005 DOI: 10.1016/j.medengphy.2023.103961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2022] [Revised: 02/15/2023] [Accepted: 02/16/2023] [Indexed: 02/19/2023]
Abstract
BACKGROUND Exoskeletons have become an important tool to help patients with upper extremity motor dysfunction in rehabilitation training and life assistance. In the study of the upper limb exoskeleton, the human glenohumeral joint will produce accompanying movement during the movement of the shoulder joint. This phenomenon causes a positional deviation between the shoulder joint and the exoskeleton, which affects the accuracy of exoskeleton-assisted human movement and the wearing comfort. Spend. METHOD Taking the coronal adduction and abduction of the shoulder joint as the research object, the shoulder joint angle and glenohumeral joint bony motion trajectory were fitted by bi-level X-rays, and then the Ultium Motion motion capture system was used to collect the characteristic motion of the shoulder joint surface and establish a model. A back-propagation neural network with shoulder joint motion and shoulder width as input and the coronal position of the glenohumeral joint as output, finally applied the model to the Nimbot exoskeleton upper limb rehabilitation training robot to verify the effectiveness of the algorithm. RESULTS Real-time prediction of the glenohumeral joint motion trajectory was achieved, and the human-machine coupling compliance during the wearing of the upper limb exoskeleton was improved.
Collapse
Affiliation(s)
- Yi Tang
- Institute of Rehabilitation Engineering and Technology, University of Shanghai for Science and Technology, Shanghai, 200093, China
| | - Duo Hao
- Department of Rehabilitation, Changhai Hospital, Naval Medical University, Shanghai, 200433, China
| | - Chengbing Cao
- Department of Rehabilitation, Changhai Hospital, Naval Medical University, Shanghai, 200433, China
| | - Ping Shi
- Institute of Rehabilitation Engineering and Technology, University of Shanghai for Science and Technology, Shanghai, 200093, China.
| | - Hongliu Yu
- Institute of Rehabilitation Engineering and Technology, University of Shanghai for Science and Technology, Shanghai, 200093, China
| | - Xiaowei Luan
- Department of Rehabilitation, Changhai Hospital, Naval Medical University, Shanghai, 200433, China
| | - Fanfu Fang
- Department of Rehabilitation, Changhai Hospital, Naval Medical University, Shanghai, 200433, China.
| |
Collapse
|
15
|
Lewis CL, Uemura K, Atkins PR, Lenz AL, Fiorentino NM, Aoki SK, Anderson AE. Patients with cam-type femoroacetabular impingement demonstrate increased change in bone-to-bone distance during walking: A dual fluoroscopy study. J Orthop Res 2023; 41:161-169. [PMID: 35325481 PMCID: PMC9508282 DOI: 10.1002/jor.25332] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Revised: 02/24/2022] [Accepted: 03/22/2022] [Indexed: 02/07/2023]
Abstract
Cam-type femoroacetabular impingement (FAI) syndrome is a painful, structural hip disorder. Herein, we investigated hip joint mechanics through in vivo, dynamic measurement of the bone-to-bone distance between the femoral head and acetabulum in patients with cam FAI syndrome and morphologically screened controls. We hypothesized that individuals with cam FAI syndrome would have larger changes in bone-to-bone distance compared to the control group, which we would interpret as altered joint mechanics as signified by greater movement of the femoral head as it articulates within the acetabulum. Seven patients with cam FAI syndrome and 11 asymptomatic individuals with typical morphology underwent dual fluoroscopy imaging during level and inclined walking (upward slope). The change in bone-to-bone distance between femoral and acetabular bone surfaces was evaluated for five anatomical regions of the acetabulum at each timepoint of gait. Linear regression analysis of the bone-to-bone distance considered two within-subject factors (activity and region) and one between-subjects factor (group). Across activities, the change in minimum bone-to-bone distance was 1.38-2.54 mm for the cam FAI group and 1.16-1.84 mm for controls. In all regions except the anterior-superior region, the change in bone-to-bone distance was larger in the cam group than the control group (p ≤ 0.024). An effect of activity was detected only in the posterior-superior region where larger changes were noted during level walking than incline walking. Statement of clinical significance: Patients with cam FAI syndrome exhibit altered hip joint mechanics during the low-demand activity of walking; these alterations could affect load transmission, and contribute to pain, tissue damage, and osteoarthritis.
Collapse
Affiliation(s)
- Cara L Lewis
- Department of Physical Therapy and Athletic Training, Boston University, Boston, Massachusetts, USA
| | - Keisuke Uemura
- Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA
| | - Penny R Atkins
- Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA
- Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, Utah, USA
| | - Amy L Lenz
- Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA
| | - Niccolo M Fiorentino
- Department of Mechanical Engineering, University of Vermont, Burlington, Vermont, USA
| | - Stephen K Aoki
- Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA
| | - Andrew E Anderson
- Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA
- Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, Utah, USA
- Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah, USA
- Department of Physical Therapy, University of Utah, Salt Lake City, Utah, USA
| |
Collapse
|
16
|
Oyekan AA, LeVasseur CM, Shaw JD, Donaldson WF, Lee JY, Anderst WJ. Changes in intervertebral sagittal alignment of the cervical spine from supine to upright. J Orthop Res 2022. [PMID: 36484123 DOI: 10.1002/jor.25500] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Cervical sagittal alignment is a critical component of successful surgical outcomes. Unrecognized differences in intervertebral alignment between supine and upright positions may affect clinical outcomes; however, these differences have not been quantified. Sixty-four patients scheduled to undergo one or two-level cervical arthrodesis for symptomatic pathology from C4-C5 to C6-C7, and forty-seven controls were recruited. Upright sagittal alignment was obtained through biplane radiographic imaging and measured using a validated process with accuracy better than 1° in rotation. Supine alignment was obtained from computed tomography scans. Coordinate systems used to measure supine and upright alignment were identical. Distances between adjacent bony endplates were measured to calculate disc height in each position. For both patients and controls, the C1-C2, C2-C3, and C3-C4 motion segments were in more lordosis when upright as compared with supine (all p < 0.001). However, the C4-C5, C5-C6, and C6-C7 motion segments were in less lordosis when upright as compared with supine (all p ≤ 0.004). There was an interaction between group and position at the C1-C2 (p = 0.002) and C2-C3 (p = 0.001) motion segments, with the controls demonstrating a greater increase in lordosis at both motion segments when moving from supine to upright. The results indicate that cervical motion segment alignment changes between supine and upright positioning, those changes differ among motion segments, and cervical pathology affects the magnitude of these changes. Clinical Significance: Surgeons should be mindful of the differences in alignment between supine and upright imaging and the implications they may have on clinical outcomes.
Collapse
Affiliation(s)
- Anthony A Oyekan
- Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.,Pittsburgh Ortho Spine Research (POSR) Group, University of Pittsburgh, Pittsburgh, PA, USA.,Biodynamics Laboratory, Orthopaedic Research Laboratories, University of Pittsburgh, Pittsburgh, PA, USA
| | - Clarissa M LeVasseur
- Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.,Pittsburgh Ortho Spine Research (POSR) Group, University of Pittsburgh, Pittsburgh, PA, USA.,Biodynamics Laboratory, Orthopaedic Research Laboratories, University of Pittsburgh, Pittsburgh, PA, USA
| | - Jeremy D Shaw
- Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.,Pittsburgh Ortho Spine Research (POSR) Group, University of Pittsburgh, Pittsburgh, PA, USA.,Biodynamics Laboratory, Orthopaedic Research Laboratories, University of Pittsburgh, Pittsburgh, PA, USA
| | - William F Donaldson
- Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.,Pittsburgh Ortho Spine Research (POSR) Group, University of Pittsburgh, Pittsburgh, PA, USA.,Biodynamics Laboratory, Orthopaedic Research Laboratories, University of Pittsburgh, Pittsburgh, PA, USA
| | - Joon Y Lee
- Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.,Pittsburgh Ortho Spine Research (POSR) Group, University of Pittsburgh, Pittsburgh, PA, USA.,Biodynamics Laboratory, Orthopaedic Research Laboratories, University of Pittsburgh, Pittsburgh, PA, USA
| | - William J Anderst
- Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.,Pittsburgh Ortho Spine Research (POSR) Group, University of Pittsburgh, Pittsburgh, PA, USA.,Biodynamics Laboratory, Orthopaedic Research Laboratories, University of Pittsburgh, Pittsburgh, PA, USA
| |
Collapse
|
17
|
Wu C, Wang Y, Wang C, Chen J, Xu J, Yu W, Huang K, Ye Z, Jiang J, Tsai TY, Zhao J, Xie G. Glenoid Track Width Is Smaller Under Dynamic Conditions: An In Vivo Dual-Fluoroscopy Imaging Study. Am J Sports Med 2022; 50:3881-3888. [PMID: 36300554 DOI: 10.1177/03635465221126650] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND The glenoid track concept has been widely used to assess the risk of instability due to bipolar bone loss. The glenoid track width was commonly used as 83% of the glenoid width to determine if a lesion was on-track or off-track. However, the value was obtained under static conditions, and it may not be able to reflect the actual mechanism of traumatic dislocation during motion. PURPOSE To compare the glenoid track width under dynamic and static conditions using a dual-fluoroscopic imaging system. STUDY DESIGN Controlled laboratory study. METHODS In total, 40 shoulders of 20 healthy volunteers were examined for both dynamic and static tests within a dual-fluoroscopic imaging system at 5 different arm positions: 30°, 60°, 90°, 120°, and 150° of abduction, keeping the shoulder at 90° of external rotation. The participants performed a fast horizontal arm backswing for dynamic tests while keeping their arm in maximum horizontal extension for static tests. Computed tomography scans were used to create 3-dimensional models of the humerus and scapula for 2-dimensional to 3-dimensional image registration. Magnetic resonance imaging scans were obtained to delineate the medial margin of the rotator cuff insertion. The glenoid track width was measured as the distance from the anterior rim of the glenoid to the medial margin of the rotator cuff insertion and compared between static and dynamic conditions. RESULTS The mean glenoid track widths at 30°, 60°, 90°, 120°, and 150° of abduction were significantly smaller under dynamic conditions (88%, 81%, 72%, 69%, and 68% of the glenoid width) than those under static conditions (101%, 92%, 84%, 78%, and 77% of the glenoid width) (all P < .001). The glenoid track width significantly decreased with the increasing abduction angles in the range of 30° to 120° under static conditions (all P < .003) and 30° to 90° under dynamic conditions (all P < .001). CONCLUSION A smaller dynamic-based value should be considered for the glenoid track width when distinguishing on-track/off-track lesions. Clinical evidence is needed to establish the superiority of the dynamic-based value over the static-based value as an indicator for augmentation procedures. CLINICAL RELEVANCE Some off-track lesions might be misclassified as on-track lesions when the original commonly used static-based value of 83% is used as the glenoid track width.
Collapse
Affiliation(s)
- Chenliang Wu
- Department of Sports Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Yufan Wang
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China.,Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Shanghai, China.,Department of Orthopaedic Surgery, Shanghai Key Laboratory of Orthopaedic Implants and Clinical Translational R&D Center of 3D Printing Technology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Cong Wang
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China.,Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Shanghai, China.,Department of Orthopaedic Surgery, Shanghai Key Laboratory of Orthopaedic Implants and Clinical Translational R&D Center of 3D Printing Technology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Jiebo Chen
- Department of Sports Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Junjie Xu
- Department of Sports Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Wanxin Yu
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China.,Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Shanghai, China.,Department of Orthopaedic Surgery, Shanghai Key Laboratory of Orthopaedic Implants and Clinical Translational R&D Center of 3D Printing Technology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Kai Huang
- Department of Sports Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Zipeng Ye
- Department of Sports Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Jia Jiang
- Department of Sports Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Tsung-Yuan Tsai
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China.,TaoImage Medical Technologies Corporation, Shanghai, China
| | - Jinzhong Zhao
- Department of Sports Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Guoming Xie
- Department of Sports Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| |
Collapse
|
18
|
Sulkar HJ, Aliaj K, Tashjian RZ, Chalmers PN, Foreman KB, Henninger HB. Reverse Total Shoulder Arthroplasty Alters Humerothoracic, Scapulothoracic, and Glenohumeral Motion During Weighted Scaption. Clin Orthop Relat Res 2022; 480:2254-2265. [PMID: 35857295 PMCID: PMC9555951 DOI: 10.1097/corr.0000000000002321] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Accepted: 06/22/2022] [Indexed: 01/31/2023]
Abstract
BACKGROUND Reverse total shoulder arthroplasty (rTSA) typically restores active arm elevation. Prior studies in patients with rTSA during tasks that load the arm had limitations that obscured underlying three-dimensional (3D) kinematic changes and the origins of motion restrictions. Understanding the scapulothoracic and glenohumeral contributions to loaded arm elevation will uncover where functional deficits arise and inform strategies to improve rTSA outcomes. QUESTIONS/PURPOSES In a cohort of patients who had undergone rTSA and a control cohort, we asked: (1) Is there a difference in maximum humerothoracic elevation when scapular plane elevation (scaption) is performed with and without a handheld weight? (2) Is maximum humerothoracic elevation related to factors like demographics, patient-reported outcome scores, isometric strength, and scapular notching (in the rTSA group only)? (3) Are there differences in underlying 3D scapulothoracic and glenohumeral motion during scaption with and without a handheld weight? METHODS Ten participants who underwent rTSA (six males, four females; age 73 ± 8 years) were recruited at follow-up visits if they were more than 1 year postoperative (24 ± 11 months), had a BMI less than 35 kg/m 2 (29 ± 4 kg/m 2 ), had a preoperative CT scan, and could perform pain-free scaption. Data from 10 participants with a nonpathologic shoulder, collected previously (five males, five females; age 58 ± 7 years; BMI 26 ± 3 kg/m 2 ), were a control group with the same high-resolution quantitative metrics available for comparison. Participants in both groups performed scaption with and without a 2.2-kg handheld weight while being imaged with biplane fluoroscopy. Maximum humerothoracic elevation and 3D scapulothoracic and glenohumeral kinematics across their achievable ROM were collected via dynamic imaging. In the same session the American Shoulder and Elbow Surgeons (ASES) score, the Simple Shoulder Test (SST), and isometric strength were collected. Data were compared between weighted and unweighted scaption using paired t-tests and linear mixed-effects models. RESULTS When compared with unweighted scaption, maximum humerothoracic elevation decreased during weighted scaption for patients who underwent rTSA (-25° ± 30°; p = 0.03) but not for the control group (-2° ± 5°; p = 0.35). In the rTSA group, maximum elevation correlated with the ASES score (r = 0.72; p = 0.02), and weighted scaption correlated with BMI (r = 0.72; p = 0.02) and the SST (r = 0.76; p = 0.01). Scapular notching was observed in three patients after rTSA (Grades 1 and 2). Four of 10 patients who underwent rTSA performed weighted scaption to less than 90° humerothoracic elevation using almost exclusively scapulothoracic motion, with little glenohumeral contribution. This manifested as changes in the estimated coefficient representing mean differences in slopes in the humerothoracic plane of elevation (-12° ± 2°; p < 0.001) and true axial rotation (-16° ± 2°; p < 0.001), scapulothoracic upward rotation (7° ± 1°; p < 0.001), and glenohumeral elevation (-12° ± 1°; p < 0.001), plane of elevation (-8° ± 3°; p = 0.002), and true axial rotation (-11° ± 2°; p < 0.001). The control group demonstrated small differences between scaption activities (< |2°|), but a 10° increase in humerothoracic and glenohumeral axial rotation (both p < 0.001). CONCLUSION After rTSA surgery, maximum humerothoracic elevation decreased during weighted scaption by up to 88° compared with unweighted scaption, whereas 4 of 10 patients could not achieve more than 90° of elevation. These patients exhibited appreciable changes in nearly all scapulothoracic and glenohumeral degrees of freedom, most notably a near absence of glenohumeral elevation during weighted scaption. Patients with rTSA have unique strategies to elevate their arms, often with decreased glenohumeral motion and resultant compensation in scapulothoracic motion. In contrast, the control group showed few differences when lifting a handheld weight. CLINICAL RELEVANCE Functional deficiency in activities that load the shoulder after rTSA surgery can affect patient independence, and they may be prevalent but not captured in clinical studies. Pre- or postoperative rehabilitation to strengthen scapular stabilizers and the deltoid should be evaluated against postoperative shoulder function. Further study is required to determine the etiology of deficient glenohumeral motion after rTSA, and the most effective surgical and/or rehabilitative strategies to restore deficient glenohumeral motion after rTSA.
Collapse
Affiliation(s)
- Hema J. Sulkar
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, USA
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA
| | - Klevis Aliaj
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, USA
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA
| | | | - Peter N. Chalmers
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, USA
| | - K. Bo Foreman
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, USA
- Department of Physical Therapy and Athletic Training, University of Utah, Salt Lake City, UT, USA
| | - Heath B. Henninger
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, USA
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA
- Department of Mechanical Engineering, University of Utah, Salt Lake City, UT, USA
| |
Collapse
|
19
|
Yeni YN, Azad S, Oravec D, Schildcrout A, Basheer A, Bey MJ, Bartol SW, Chang V. Intervertebral kinematics during neck motion 6.5 years after fusion and artificial disc replacement. Clin Biomech (Bristol, Avon) 2022; 99:105756. [PMID: 36063742 DOI: 10.1016/j.clinbiomech.2022.105756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Revised: 08/24/2022] [Accepted: 08/26/2022] [Indexed: 02/07/2023]
Abstract
BACKGROUND Arthroplasty with artificial disc replacement for surgical treatment of cervical spine degeneration was introduced with the notion that motion-preserving approaches would prevent development of adjacent segment disease. Though clinical outcomes favor arthroplasty over the commonly used anterior cervical discectomy with fusion approach, clinical studies confirming the biomechanical basis of these results are lacking. The aim of this study was to compare intervertebral kinematics between arthroplasty and fusion patients 6.5 years post-surgery during physiological motion of the neck. METHODS Using a biplane dynamic X-ray system, computed tomography imaging and model based tracking algorithms, three dimensional intervertebral kinematics were measured during neck axial rotation and extension in 14 patients treated for cervical radiculopathy with fusion (n = 8) or arthroplasty (n = 6). The measurements were performed at 2-year (baseline) and 6.5 year post-surgical time points, with the main interest being in the interaction between surgery types and time points. 3 translations and 3 rotations were investigated for the index (C5C6), and upper- (C4C5) and lower adjacent levels (C6C7). FINDINGS Surgery-time interaction was significant for axial rotation (P < 0.04) and flexion-extension rotation (P < 0.005) in C4C5 during neck axial rotation, left-right translation (P < 0.04) in C5C6 and anterior-posterior translation in C6C7 (P < 0.04) during neck extension. In contrast with the expectations, axial rotation and flexion-extension decreased in C4C5 during neck rotation and anterior-posterior translation decreased in C6C7 during neck extension for fusion. INTERPRETATION The findings do not support the notion that adjacent segment motion increases after fusion.
Collapse
Affiliation(s)
- Yener N Yeni
- Bone and Joint Center, Department of Orthopedics, Henry Ford Health System, Detroit, MI, USA.
| | - Sherwin Azad
- Bone and Joint Center, Department of Orthopedics, Henry Ford Health System, Detroit, MI, USA; School of Medicine, Wayne State University, Detroit, MI, USA
| | - Daniel Oravec
- Bone and Joint Center, Department of Orthopedics, Henry Ford Health System, Detroit, MI, USA
| | - Andrew Schildcrout
- Bone and Joint Center, Department of Orthopedics, Henry Ford Health System, Detroit, MI, USA
| | - Azam Basheer
- Department of Neurosurgery, Henry Ford Health System, Detroit, MI, USA
| | - Michael J Bey
- Bone and Joint Center, Department of Orthopedics, Henry Ford Health System, Detroit, MI, USA
| | - Stephen W Bartol
- Bone and Joint Center, Department of Orthopedics, Henry Ford Health System, Detroit, MI, USA
| | - Victor Chang
- Department of Neurosurgery, Henry Ford Health System, Detroit, MI, USA
| |
Collapse
|
20
|
Munsch MA, Como CJ, Gale TH, Fowler JR, Anderst WJ. Validation of Dynamic Biplane Radiography and Three-Dimensional Model-Based Tracking for Evaluation of Dynamic Thumb Kinematics. J Biomech 2022; 142:111236. [DOI: 10.1016/j.jbiomech.2022.111236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 07/07/2022] [Accepted: 07/27/2022] [Indexed: 11/16/2022]
|
21
|
Ruh E, Johnson C, Frankston N, Charles S, Anderst W, McClincy M. Does Femoral Head Translation Vary by Sex and Side in Asymptomatic Hips During a Weightbearing Apprehension Test? Clin Orthop Relat Res 2022; 480:1104-1111. [PMID: 35195575 PMCID: PMC9263503 DOI: 10.1097/corr.0000000000002144] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Accepted: 01/27/2022] [Indexed: 01/31/2023]
Abstract
BACKGROUND Hip microinstability is an increasingly recognized source of pain and dysfunction but has no agreed upon diagnostic criteria and the pathophysiology remains unclear. It has been suggested that pain associated with microinstability is caused by excess translation of the femoral head. Recent research indicates that single-plane femoral head translation can be reliably measured using dynamic ultrasonography during a supine clinical examination; however, the overall accuracy of that technique has not been established, and the range of femoral head translation values that are found in individuals with no history of surgery or symptomatic pathology is unknown. QUESTIONS/PURPOSES (1) How much femoral head translation is present in native, uninjured hips during a weightbearing apprehension position for females and males? (2) How large is the side-to-side difference in hip translation and rotation within the same individual in females and males with no history of surgery or pain during the weightbearing apprehension position? (3) What differences exist in femoral head translation and rotation when comparing females to males? METHODS Twenty-two young adults (11 males, 11 females; mean age 22 ± 2 years; BMI 22 ± 5 kg/m2) with no history of hip pain, no known hip injury, and who never had hip surgery participated in this study. High-resolution CT images of the femur and pelvis were acquired for each participant, and the bone tissue was segmented from the CT volume. Synchronized biplane radiographs were collected during a neutral standing trial and during a static weightbearing apprehension position in which the participant extended, externally rotated, and abducted at their back hip while standing with their feet split in the AP direction. A validated volumetric model-based tracking technique was used to match the patient-specific bone models to the biplane radiographs with an accuracy of 0.3 mm for translation and 0.8° for rotation. Translation of the center of the femoral head relative to the center of the acetabulum and rotation of the femur relative to the pelvis from neutral to the weightbearing apprehension position were calculated. Sex-based differences in hip kinematics were assessed by bivariate linear regression. RESULTS The median (range) translation during the weightbearing apprehension position in females was 0.9 mm (0.2 to 2.7 mm), which was less than in the 1.3 mm (0.2 to 2.6 mm) translation found in males (median difference of 0.5 mm; p = 0.04). The median absolute side-to-side difference in translation during the pivot was 1.4 mm (0.1 to 3.8 mm) in females and 1.3 mm (0.1 to 4.4 mm) in males. CONCLUSION These findings demonstrate that the femoral head translates the same under bodyweight loading as previously observed during supine exam, showing the inherent stability of the hip with no history of surgery or symptomatic pathology. This study also provides normal values for comparison with individuals who have suspected microinstability. Future directions for research include directly comparing biplane radiography to alternative imaging techniques, such as dynamic ultrasound, for identifying hip microinstability and identifying threshold values for symptomatic hip microinstability. LEVEL OF EVIDENCE Level III, prognostic study.
Collapse
Affiliation(s)
- Ethan Ruh
- Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
| | - Camille Johnson
- Biodynamics Laboratory, University of Pittsburgh, Pittsburgh, PA, USA
| | - Naomi Frankston
- Biodynamics Laboratory, University of Pittsburgh, Pittsburgh, PA, USA
| | | | - William Anderst
- Biodynamics Laboratory, University of Pittsburgh, Pittsburgh, PA, USA
| | - Michael McClincy
- Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
| |
Collapse
|
22
|
Jun BJ, Ricchetti ET, Haladik J, Bey MJ, Patterson TE, Subhas N, Li ZM, Iannotti JP. Validation of a 3D CT imaging method for quantifying implant migration following anatomic total shoulder arthroplasty. J Orthop Res 2022; 40:1270-1280. [PMID: 34436796 DOI: 10.1002/jor.25170] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Revised: 06/29/2021] [Accepted: 07/30/2021] [Indexed: 02/04/2023]
Abstract
Glenoid component loosening remains a common complication following anatomic total shoulder arthroplasty (TSA); however, plain radiographs are unable to accurately detect early implant migration. The purpose of this study was to validate the accuracy of a method of postoperative, three-dimensional (3D) computed tomography (CT) imaging with metal artifact reduction (MAR) to detect glenoid component migration following anatomic TSA. Tantalum bead markers were inserted into polyethylene glenoid components for implant detection on 3D CT. In-vitro validation was performed using a glenoid component placed into a scapula sawbone and incrementally translated and rotated, with MAR 3D CT acquired at each test position. Accuracy was evaluated by root mean square error (RMSE). In-vivo validation was performed on six patients who underwent anatomic TSA, with two postoperative CT scans acquired in each patient and marker-based radiostereometric analysis (RSA) performed on the same days. Glenoid component migration was calculated relative to a scapular coordinate system for both MAR 3D CT and RSA. Accuracy was evaluated by RMSE and paired Student's t-tests. The largest RMSE on in-vitro testing was 0.24 mm in translation and 0.11° in rotation, and on in-vivo testing was 0.47 mm in translation and 1.04° in rotation. There were no significant differences between MAR 3D CT and RSA measurement methods. MAR 3D CT imaging is capable of quantifying glenoid component migration with a high level of accuracy. MAR 3D CT imaging is advantageous over RSA because it is readily available clinically and can also be used to evaluate the implant-bone interface.
Collapse
Affiliation(s)
- Bong-Jae Jun
- Department of Biomedical Engineering, Cleveland Clinic, Cleveland, Ohio, USA
| | - Eric T Ricchetti
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, Ohio, USA
| | - Jeffrey Haladik
- Department of Orthopaedic Surgery, Bone & Joint Center, Henry Ford Health System, Detroit, Michigan, USA
| | - Michael J Bey
- Department of Orthopaedic Surgery, Bone & Joint Center, Henry Ford Health System, Detroit, Michigan, USA
| | - Thomas E Patterson
- Department of Cerebrovascular Center, Cleveland Clinic, Cleveland, Ohio, USA
| | - Naveen Subhas
- Department of Radiology, Cleveland Clinic, Cleveland, Ohio, USA
| | - Zong-Ming Li
- Department of Orthopaedic Surgery, University of Arizona, Tucson, Arizona, USA
| | - Joseph P Iannotti
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, Ohio, USA
| |
Collapse
|
23
|
Mattar LT, Popchak AJ, Anderst WJ, Musahl V, Irrgang JJ, Debski RE. Associations between range of motion, strength, tear size, patient-reported outcomes, and glenohumeral kinematics in individuals with symptomatic isolated supraspinatus tears. J Shoulder Elbow Surg 2022; 31:1261-1271. [PMID: 35091074 PMCID: PMC9484487 DOI: 10.1016/j.jse.2021.12.032] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Revised: 12/17/2021] [Accepted: 12/19/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND Clinical failure associated with nonoperative treatment of rotator cuff tears may be due to inadequate characterization of the individual's functional impairments. Clinically, restricted passive range of motion (ROM) (restrictions imply capsular tightness), limitations in muscle strength, and larger rotator cuff tears are hypothesized to be related to altered glenohumeral kinematics. Understanding these relationships, as well as the relationship between glenohumeral kinematics and patient-reported outcomes (PROs) prior to exercise therapy, may help characterize functional impairments in individuals with rotator cuff tears. The objectives of the study were to describe the baseline presentation of individuals with an isolated supraspinatus tear, including passive ROM, rotator cuff muscle strength, tear size, PROs, and glenohumeral kinematics, and to determine associations among these variables. METHODS One hundred one individuals with symptomatic isolated supraspinatus tears were recruited for the study and underwent assessments of passive glenohumeral ROM, isometric muscle strength, and ultrasonography to assess anterior-posterior tear size. Glenohumeral kinematics during scapular-plane abduction were measured using biplane radiography. Furthermore, PROs including the American Shoulder and Elbow Surgeons (ASES) score and the Western Ontario Rotator Cuff Index (WORC) score were collected. RESULTS Individuals presented with decreased ROM, external rotation weakness compared with the uninvolved side, and pain and disability as measured by the ASES and WORC scores. These findings were not associated with glenohumeral kinematics, with the exception of a weak positive association between glenohumeral contact path lengths and WORC scores (ρ = 0.25, P = .03). Tear size was 11.7 ± 5.7 mm, and maximum anterior translation, superior translation, and contact path length were 3.0% ± 3.8% of glenoid width, 3.5% ± 3.8% of glenoid height, and 38.2% ± 20.7% of glenoid size, respectively. CONCLUSION Individuals with a symptomatic isolated supraspinatus tear presented with decreased ROM, external rotation weakness, and pain and disability as measured by the ASES and WORC scores. However, no abnormal kinematics associated with these limitations were observed. Thus, given that the tear is isolated to the supraspinatus tendon and no capsular restrictions are present, normal function of the glenohumeral joint may be possible during scapular-plane abduction.
Collapse
Affiliation(s)
- Luke T. Mattar
- Orthopaedic Robotics Laboratory, University of Pittsburgh, Pittsburgh, PA, USA,Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, PA, USA
| | - Adam J. Popchak
- Department of Physical Therapy, University of Pittsburgh, Pittsburgh, PA, USA
| | - William J. Anderst
- Biodynamics Laboratory, University of Pittsburgh, Pittsburgh, PA, USA,Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA, USA
| | - Volker Musahl
- Orthopaedic Robotics Laboratory, University of Pittsburgh, Pittsburgh, PA, USA,Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, PA, USA,Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA, USA
| | - James J. Irrgang
- Department of Physical Therapy, University of Pittsburgh, Pittsburgh, PA, USA,Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA, USA
| | - Richard E. Debski
- Orthopaedic Robotics Laboratory, University of Pittsburgh, Pittsburgh, PA, USA,Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, PA, USA,Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA, USA,Reprint requests: Richard E. Debski, PhD, Orthopaedic Robotics Laboratory, University of Pittsburgh, 408 Center for Bioengineering, 300 Technology Dr, Pittsburgh, PA 15219, USA. (R.E. Debski)
| |
Collapse
|
24
|
Anderst W, Fiedler G, Onishi K, McKernan G, Gale T, Paulus P. Within-subject effects of standardized prosthetic socket modifications on physical function and patient-reported outcomes. Trials 2022; 23:299. [PMID: 35413866 PMCID: PMC9006565 DOI: 10.1186/s13063-022-06205-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Accepted: 03/26/2022] [Indexed: 11/28/2022] Open
Abstract
Background Among the challenges of living with lower limb loss is the increased risk of long-term health problems that can be either attributed directly to the amputation surgery and/or prosthetic rehabilitation or indirectly to a disability-induced sedentary lifestyle. These problems are exacerbated by poorly fit prosthetic sockets. There is a knowledge gap regarding how the socket design affects in-socket mechanics and how in-socket mechanics affect patient-reported comfort and function. The objectives of this study are (1) to gain a better understanding of how in-socket mechanics of the residual limb in transfemoral amputees are related to patient-reported comfort and function, (2) to identify clinical tests that can streamline the socket design process, and (3) to evaluate the efficacy and cost of a novel, quantitatively informed socket optimization process. Methods Users of transfemoral prostheses will be asked to walk on a treadmill wearing their current socket plus 8 different check sockets with designed changes in different structural measurements that are likely to induce changes in residual limb motion, skin strain, and pressure distribution within the socket. Dynamic biplane radiography and pressure sensors will be used to measure in-socket residual limb mechanics. Patient-reported outcomes will also be collected after wearing each socket. The effects of in-socket mechanics on both physical function and patient-reported outcomes (aim 1) will be assessed using a generalized linear model. Partial correlation analysis will be used to examine the association between research-grade measurements and readily available clinical measurements (aim 2). In order to compare the new quantitative design method to the standard of care, patient-reported outcomes and cost will be compared between the two methods, utilizing the Wilcoxon-Mann-Whitney non-parametric test (aim 3). Discussion Knowledge on how prosthetic socket modifications affect residual bone and skin biomechanics itself can be applied to devise future socket designs, and the methodology can be used to investigate and improve such designs, past and present. Apart from saving time and costs, this may result in better prosthetic socket fit for a large patient population, thus increasing their mobility, participation, and overall health-related quality of life. Trial registration ClinicalTrials.gov NCT05041998. Date of registration: Sept 13, 2021.
Collapse
Affiliation(s)
- William Anderst
- Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, USA
| | - Goeran Fiedler
- Department of Rehabilitation Science and Technology, University of Pittsburgh, Pittsburgh, USA.
| | - Kentaro Onishi
- Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, USA
| | - Gina McKernan
- Human Engineering Research Laboratory, University of Pittsburgh, Pittsburgh, USA
| | - Tom Gale
- Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, USA
| | - Paige Paulus
- Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, USA
| |
Collapse
|
25
|
In Vivo Changes in Dynamic Adjacent Segment Motion 1 Year After One and Two-Level Cervical Arthrodesis. Ann Biomed Eng 2022; 50:871-881. [DOI: 10.1007/s10439-022-02964-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Accepted: 04/04/2022] [Indexed: 11/01/2022]
|
26
|
Weisse B, Lama S, Piskoty G, Affolter C, Aiyangar AK. Effect of two types of shoulder prosthesis on the muscle forces using a generic multibody model for different arm motions. Biomed Eng Online 2022; 21:17. [PMID: 35305644 PMCID: PMC8934495 DOI: 10.1186/s12938-022-00988-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Accepted: 03/07/2022] [Indexed: 11/10/2022] Open
Abstract
Background This study aims to analyze the effects of a novel dual-bearing shoulder prosthesis and a conventional reverse shoulder prosthesis on the deltoid and rotator cuff muscle forces for four different arm motions. The dual-bearing prosthesis is a glenoid-sparing joint replacement with a moving center of rotation. It has been developed to treat rotator cuff arthropathy, providing an increased post-operative functionality. Methods A three-dimensional musculoskeletal OpenSim® model of an upper body, incorporating a natural gleno-humeral joint and a scapula-thoracic joint developed by Blana et al. (J Biomech 41: 1714-1721, 2008), was used as a reference for the natural shoulder. It was modified by integrating first a novel dual-bearing prosthesis, and second, a reverse shoulder prosthesis into the shoulder joint complex. Four different arm motions, namely abduction, scaption, internal and external rotation, were simulated using an inverse kinematics approach. For each of the three models, shoulder muscle forces and joint reaction forces were calculated with a 2 kg weight in the hand. Results In general, the maximal shoulder muscle force and joint reaction force values were in a similar range for both prosthesis models during all four motions. The maximal deltoid muscle forces in the model with the dual-bearing prosthesis were 18% lower for abduction and 3% higher for scaption compared to the natural shoulder. The maximal rotator cuff muscle forces in the model with the dual-bearing prosthesis were 36% lower for abduction and 1% higher for scaption compared to the natural shoulder. Although the maximal deltoid muscle forces in the model with the dual-bearing prosthesis in internal and external rotation were 52% and 64% higher, respectively, compared to the natural shoulder, the maximal rotator cuff muscle forces were 27% lower in both motions. Conclusion The study shows that the dual-bearing shoulder prosthesis is a feasible option for patients with rotator cuff tear and has a strong potential to be used as secondary as well as primary joint replacement. The study also demonstrates that computer simulations can help to guide the continued optimization of this particular design concept for successful clinical outcomes.
Collapse
|
27
|
Aliaj K, Lawrence RL, Bo Foreman K, Chalmers PN, Henninger HB. Kinematic coupling of the glenohumeral and scapulothoracic joints generates humeral axial rotation. J Biomech 2022; 136:111059. [PMID: 35367838 PMCID: PMC9081276 DOI: 10.1016/j.jbiomech.2022.111059] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 11/22/2021] [Accepted: 03/21/2022] [Indexed: 10/18/2022]
Abstract
Glenohumeral and scapulothoracic motion combine to generate humerothoracic motion, but their discrete contributions towards humerothoracic axial rotation have not been investigated. Understanding their contributions to axial rotation is important to judge the effects of pathology, surgical intervention, and physiotherapy. Therefore, the purpose of this study was to investigate the kinematic coupling between glenohumeral and scapulothoracic motion and determine their relative contributions towards axial rotation. Twenty healthy subjects (10 M/10F, ages 22-66) were previously recorded using biplane fluoroscopy while performing arm elevation in the coronal, scapular, and sagittal planes, and external rotation in 0° and 90° of abduction. Glenohumeral and scapulothoracic contributions towards axial rotation were computed by integrating the projection of glenohumeral and scapulothoracic angular velocity onto the humeral longitudinal axis, and analyzed using one dimensional statistical parametric mapping and linear regression. During arm elevation, scapulothoracic motion supplied 13-20° (76-94%) of axial rotation, mainly via scapulothoracic upward rotation. The contribution of scapulothoracic motion towards axial rotation was strongly correlated with glenohumeral plane of elevation during arm elevation. During external rotation, scapulothoracic motion contributed 10° (8%) towards axial rotation in 0° of abduction and 15° (15%) in 90° of abduction. The contribution of scapulothoracic motion towards humerothoracic axial rotation could explain the simultaneous changes in glenohumeral plane of elevation and axial rotation associated with some pathologies and surgeries. Understanding how humerothoracic motion results from the functional coupling of scapulothoracic and glenohumeral motions may inform diagnostic and treatment strategies by targeting the source of movement impairments in clinical populations.
Collapse
|
28
|
Mozingo JD, Schuring LL, Mortensen AJ, Anderson AE, Aoki SK. Effect of Patient Positioning on Measurement of the Anterior Center-Edge Angle on False-Profile Radiographs and Its 3-Dimensional Mapping to the Acetabular Rim. Orthop J Sports Med 2022; 10:23259671211073834. [PMID: 35141341 PMCID: PMC8819774 DOI: 10.1177/23259671211073834] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Accepted: 11/11/2021] [Indexed: 11/17/2022] Open
Abstract
Background: The anterior center-edge angle (ACEA) is used to quantify anterior coverage of the femoral head by the acetabulum. However, its measurement has not been evaluated in a manner consistent with routine use, and the precise 3-dimensional (3D) anatomic location where it measures coverage is not known. Purpose: To determine the effect of patient positioning on ACEA measurement reliability, magnitude, and 3D location. Study Design: Descriptive laboratory study. Methods: Included were 18 adults; 7 participants had cam morphology and femoroacetabular impingement syndrome, and 11 participants had no radiographic evidence of hip abnormalities and no history of hip pain or injuries. Ultimately, 3D femur and pelvis models were generated from computed tomography images. Radiographs were generated with the models in different degrees of pelvic rotation, tilt, and obliquity relative to the standard false-profile view. The ACEA was measured by 2 raters by selecting the location of the bone edge on each radiograph. Selections were projected onto the pelvis model and expressed as a clockface location on the acetabular rim. The clockface was mirrored on left hips to allow a direct comparison of locations between hips. Interrater and intrarater reliability were quantified via the intraclass correlation coefficient (ICC). The effect of position on ACEA measurements and clockface locations was determined via linear regression. Results: Intrarater and interrater reliability were excellent (ICC ≥0.97 for all). For every degree increase in rotation, tilt, and obliquity, the ACEA changed by +0.53°, +0.93°, and –0.04°, respectively. The mean clockface location (hour:minute:second) in the false-profile view was 2:09:32 ± 0:12:00 and changed by +0:02:08, –0:00:35, and –0:00:05 for every degree increase in rotation, tilt, and obliquity, respectively. Conclusion: ACEA measurements were reliable even with differences in patient positioning. Rotation and tilt were associated with notable changes in ACEA measurements. ACEA bone edge measurements mapped to the anterosuperior acetabular rim, typically in proximity to the anterior inferior iliac spine. Mapped location was most sensitive to rotation. Clinical Relevance: Pelvic rotation and tilt affected ACEA measurements, which could alter the clinical classification and treatment of borderline abnormalities. Rotation in particular must be well controlled during patient imaging to preserve measurement reliability and accuracy and to describe coverage from the intended 3D rim location.
Collapse
Affiliation(s)
- Joseph D. Mozingo
- Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA
| | - Lindsay L. Schuring
- Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA
- Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah, USA
| | | | - Andrew E. Anderson
- Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA
- Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah, USA
- Department of Physical Therapy and Athletic Training, University of Utah, Salt Lake City, Utah, USA
- Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, Utah, USA
| | - Stephen K. Aoki
- Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA
| |
Collapse
|
29
|
Kane GE, LeVasseur CM, Hughes JD, Gabrielli AS, Popchak A, Anderst W, Lin A. Improved Outcomes Following Arthroscopic Superior Capsular Reconstruction May Not Be Associated With Changes in Shoulder Kinematics: An In Vivo Study. Arthroscopy 2022; 38:267-275. [PMID: 34237396 DOI: 10.1016/j.arthro.2021.06.018] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 05/21/2021] [Accepted: 06/30/2021] [Indexed: 02/02/2023]
Abstract
PURPOSE To determine the in vivo effects of superior capsule reconstruction (SCR) on glenohumeral kinematics during abduction and to compare those kinematics results with patient-reported outcomes, range of motion, and strength. METHODS Dynamic biplane radiography was used to image 10 patients with irreparable rotator cuff tears while performing scapular plane abduction pre- and 1-year post-surgery. Shoulder kinematics were determined by matching subject-specific computed tomography-based bone models to the radiographs using a validated tracking technique. RESULTS No change was detected in static acromiohumeral distance (-0.7 ± 2.1 mm; P = .35); however, average dynamic acromiohumeral distance decreased (2.7 ± 1.2 mm to 2.3 ± 1.0 mm; P = .035) from pre- to 1-year post-surgery, respectively. The humeral head position was 0.5 ± 0.5 mm more superior 1-year post-surgery compared with pre-surgery (P = .01). Glenohumeral abduction increased from pre-surgery (150 ± 20°) to 1-year post-surgery (165 ± 10°) (P = .04) and all patient-reported outcomes improved from pre-surgery to 1-year post-surgery (all P < .002). A more posterior shift in humeral head position was associated with improved American Shoulder and Elbow Surgeons Shoulder Score from pre-surgery to 1-year post-surgery (r = 0.71, P = .02). CONCLUSIONS These data suggest that SCR may not depress the humeral head during functional abduction, as previously postulated, and postoperative improvements in subjective and clinical outcomes may be affected by mechanisms other than changes in shoulder kinematics. CLINICAL RELEVANCE In vivo kinematics changes after SCR are small and do not correspond to previously postulated changes.
Collapse
Affiliation(s)
- Gillian E Kane
- Department of Orthopedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, U.S.A
| | - Clarissa M LeVasseur
- Department of Orthopedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, U.S.A..
| | - Jonathan D Hughes
- Department of Orthopedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, U.S.A
| | - Alexandra S Gabrielli
- Department of Orthopedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, U.S.A
| | - Adam Popchak
- Department of Orthopedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, U.S.A
| | - William Anderst
- Department of Orthopedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, U.S.A
| | - Albert Lin
- Department of Orthopedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, U.S.A
| |
Collapse
|
30
|
Mozingo JD, Akbari-Shandiz M, Van Straaten MG, Murthy NS, Schueler BA, Holmes DR, McCollough CH, Zhao KD. Comparison of glenohumeral joint kinematics between manual wheelchair tasks and implications on the subacromial space: A biplane fluoroscopy study. J Electromyogr Kinesiol 2022; 62:102350. [PMID: 31481296 PMCID: PMC7036020 DOI: 10.1016/j.jelekin.2019.08.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Revised: 07/12/2019] [Accepted: 08/19/2019] [Indexed: 02/03/2023] Open
Abstract
Scapula and humerus motion associated with common manual wheelchair tasks is hypothesized to reduce the subacromial space. However, previous work relied on either marker-based motion capture for kinematic measures, which is prone to skin-motion artifact; or ultrasound imaging for arthrokinematic measures, which are 2D and acquired in statically-held positions. The aim of this study was to use a fluoroscopy-based approach to accurately quantify glenohumeral kinematics during manual wheelchair use, and compare tasks for a subset of parameters theorized to be associated with mechanical impingement. Biplane images of the dominant shoulder were acquired during scapular plane elevation, propulsion, sideways lean, and weight-relief raise in ten manual wheelchair users with spinal cord injury. A computed tomography scan of the shoulder was obtained, and model-based tracking was used to quantify six-degree-of-freedom glenohumeral kinematics. Axial rotation and superior/inferior and anterior/posterior humeral head positions were characterized for full activity cycles and compared between tasks. The change in the subacromial space was also determined for the period of each task defined by maximal change in the aforementioned parameters. Propulsion, sideways lean, and weight-relief raise, but not scapular plane elevation, were marked by mean internal rotation (8.1°, 10.8°, 14.7°, -49.2° respectively). On average, the humeral head was most superiorly positioned during the weight-relief raise (1.6 ± 0.9 mm), but not significantly different from the sideways lean (0.8 ± 1.1 mm) (p = 0.191), and much of the task was characterized by inferior translation. Scaption was the only task without a defined period of superior translation on average. Pairwise comparisons revealed no significant differences between tasks for anterior/posterior position (task means range: 0.1-1.7 mm), but each task exhibited defined periods of anterior translation. There was not a consistent trend across tasks between internal rotation, superior translation, and anterior translation with reductions in the subacromial space. Further research is warranted to determine the likelihood of mechanical impingement during these tasks based on the measured task kinematics and reductions in the subacromial space.
Collapse
Affiliation(s)
- Joseph D. Mozingo
- Biomedical Engineering and Physiology Graduate Program,
Mayo Clinic Graduate School of Biomedical Sciences, Mayo Clinic, Rochester, MN,
USA,Department of Physical Medicine and Rehabilitation, Mayo
Clinic, Rochester, MN, USA
| | | | | | | | | | - David R. Holmes
- Department of Physiology and Biomedical Engineering, Mayo
Clinic, Rochester, MN, USA
| | | | - Kristin D. Zhao
- Department of Physical Medicine and Rehabilitation, Mayo
Clinic, Rochester, MN, USA
| |
Collapse
|
31
|
Canton SP, Gale T, Onyeukwu C, Hogan MV, Anderst W. Syndesmosis Repair Affects in Vivo Distal Interosseous Tibiofibular Ligament Elongation Under Static Loads and During Dynamic Activities. J Bone Joint Surg Am 2021; 103:1927-1936. [PMID: 34043595 DOI: 10.2106/jbjs.20.01787] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Ligamentous ankle injuries are the most common injuries sustained by athletes and by the general population, with an incidence of approximately 2 million per year in the U.S. Injuries to the ankle syndesmosis (i.e., "high ankle sprains") are generally treated operatively. Although cadaveric studies can evaluate syndesmosis fixation strength, they cannot predict how healing, neuromuscular adaptation, or dynamic loading will affect in vivo biomechanics. Using dynamic biplane radiography (DBR), we tested the hypothesis that syndesmosis repair would restore ankle kinematics and ligament elongation during static and dynamic loading. METHODS A convenience sample of 6 male patients who had undergone fixation (2 screw, 3 suspensory, 1 hybrid) of syndesmosis injury were assessed with use of DBR during forward running, backpedaling, a 45° angled single-leg hop, and 1 static standing trial at 2 to 4.5 years postoperatively. Three-dimensional ankle kinematics and elongation of the distal interosseous ligament, anterior inferior tibiofibular ligament, and the posterior inferior tibiofibular ligament were measured bilaterally. Comparisons were made between the operative and uninjured sides. Clinical outcomes were evaluated with use of the Foot and Ankle Ability Measure. RESULTS Static load increased the lengths of the distal interosseous ligament (p = 0.02 to 0.05) and middle segment of the anterior inferior tibiofibular ligament (p = 0.02) in the operative ankle. The distal syndesmosis length was greater on the operative side during the static unloaded and loaded conditions (p = 0.02). Length of the distal syndesmosis on the operative side was greater than the corresponding healthy syndesmosis length during all 3 dynamic activities. On average, the operative ankle was in less dorsiflexion over the support phase of the angled hop (p = 0.05) and running (p < 0.01). The average Foot and Ankle Ability Measure Activities of Daily Living and Sports subscale scores were 95 and 88, respectively. CONCLUSIONS This study provides the first in vivo evidence of post-fixation changes in biomechanics after syndesmosis repair. Syndesmosis repair fails to restore healthy static and dynamic distal tibiofibular anatomy, even in patients who report good to excellent clinical outcomes. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Stephen P Canton
- University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania.,Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania
| | - Tom Gale
- Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania
| | - Chukwudi Onyeukwu
- University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania.,Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania
| | - MaCalus V Hogan
- University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania.,Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania.,Foot and Ankle Injury Research [F.A.I.R] Group, University of Pittsburgh, Pittsburgh, Pennsylvania
| | - William Anderst
- University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania.,Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania
| |
Collapse
|
32
|
Rohwedder T. Biomechanics of the Canine Elbow Joint. Vet Med Sci 2021. [DOI: 10.5772/intechopen.99569] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
The canine elbow joint is a complex joint, whose musculoskeletal anatomy is well investigated. During the last 30 years kinematic analysis has gained importance in veterinary research and kinematics of the healthy and medial coronoid disease affected canine elbow joint are progressively investigated. Video-kinematographic analysis represents the most commonly used technique and multiple studies have investigated the range of motion, angular velocity, duration of swing and stance phase, stride length and other kinematic parameters, mostly in the sagittal plane only. However, this technique is more error-prone and data gained by video-kinematography represent the kinematics of the whole limb including the soft tissue envelope. A more precise evaluation of the in vivo bone and joint movement can only been achieved using fluoroscopic kinematography. Based on recent studies significant differences in the motion pattern between healthy joints and elbows with medial coronoid disease could be detected. Thereby not only adaptive changes, caused by pain and lameness, could be described, but primary changes in the micromotion of the joint forming bones could be found, which potentially represent new factors in the pathogenesis of medial coronoid disease. This chapter gives a review of current literature on elbow joint kinematics, with particular focus onto pathologic biomechanics in dysplastic canine elbows.
Collapse
|
33
|
Maikos JT, Chomack JM, Loan JP, Bradley KM, D'Andrea SE. Effects of Prosthetic Socket Design on Residual Femur Motion Using Dynamic Stereo X-Ray - A Preliminary Analysis. Front Bioeng Biotechnol 2021; 9:697651. [PMID: 34447740 PMCID: PMC8383143 DOI: 10.3389/fbioe.2021.697651] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Accepted: 07/21/2021] [Indexed: 11/13/2022] Open
Abstract
Individuals with transfemoral amputation experience relative motion between their residual limb and prosthetic socket, which can cause inefficient dynamic load transmission and secondary comorbidities that limit mobility. Accurately measuring the relative position and orientation of the residual limb relative to the prosthetic socket during dynamic activities can provide great insight into the complex mechanics of the socket/limb interface. Five participants with transfemoral amputation were recruited for this study. All participants had a well-fitting, ischial containment socket and were also fit with a compression/release stabilization socket. Participants underwent an 8-wk, randomized crossover trial to compare differences between socket types. Dynamic stereo x-ray was used to quantify three-dimensional residual bone kinematics relative to the prosthetic socket during treadmill walking at self-selected speed. Comfort, satisfaction, and utility were also assessed. There were no significant differences in relative femur kinematics between socket types in the three rotational degrees of freedom, as well as anterior-posterior and medial-lateral translation (p > 0.05). The ischial containment socket demonstrated significantly less proximal-distal translation (pistoning) of the femur compared to the compression/release stabilization socket during the gait cycle (p < 0.05), suggesting that the compression/release stabilization socket provided less control of the residual femur during distal translation. No significant differences in comfort and utility were found between socket types (p > 0.05). The quantitative, dynamic analytical tools used in the study were sensitive to distinguish differences in three-dimensional residual femur motion between two socket types, which can serve as a platform for future comparative effectiveness studies of socket technology.
Collapse
Affiliation(s)
- Jason T Maikos
- VISN 2 Biomechanics Research for the Advancement of Veteran Outcomes Laboratory, Veterans Affairs New York Harbor Healthcare System, New York, NY, United States
| | - John M Chomack
- VISN 2 Biomechanics Research for the Advancement of Veteran Outcomes Laboratory, Veterans Affairs New York Harbor Healthcare System, New York, NY, United States
| | | | | | - Susan E D'Andrea
- Virtual Reality and Motion Analysis Rehabilitation Laboratory, Providence VA Medical Center, Providence, RI, United States
| |
Collapse
|
34
|
Zhang C, Sun X, Tang Y, Wang S, Ye D, Fu W, Liu Y, Huang L. Advances in the Application of the Dual Fluoroscopic Imaging System in Sports Medicine: A Literature Review. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS 2021. [DOI: 10.1166/jmihi.2021.3579] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The dual fluoroscopic imaging system (DFIS) is a new non-invasive motion analysis system that does not interfere with movement, has high precision and repeatability and is not affected by the errors caused by the relative movement of skin and soft tissues. DFIS has been recently used
in the field of sports medicine. This narrative review focuses on relevant literature on the origin, development and mechanism of action of DFIS and summarises the application of DFIS in injury and rehabilitation treatment, such as the reliability of test results; the position relationships
of bony structures in the shoulder, lumbar spine, knee joint and ankle joint during exercise and its six degree-of-freedom (6DOF) movement to calculate cartilage deformation, contact area/trajectory and ligament strain. This article puts forward the problems encountered in practice that need
to be solved and looks forward to the future applications of DFIS in the field of sports, especially in injury prevention and treatment.
Collapse
Affiliation(s)
- Cui Zhang
- School of Kinesiology, Shanghai University of Sport, Shanghai 200438, China
| | - Xiaole Sun
- School of Kinesiology, Shanghai University of Sport, Shanghai 200438, China
| | - Yunqi Tang
- School of Kinesiology, Shanghai University of Sport, Shanghai 200438, China
| | - Shaobai Wang
- School of Kinesiology, Shanghai University of Sport, Shanghai 200438, China
| | - Dongqiang Ye
- School of Kinesiology, Shanghai University of Sport, Shanghai 200438, China
| | - Weijie Fu
- School of Kinesiology, Shanghai University of Sport, Shanghai 200438, China
| | - Yu Liu
- School of Kinesiology, Shanghai University of Sport, Shanghai 200438, China
| | - Lingyan Huang
- School of Kinesiology, Shanghai University of Sport, Shanghai 200438, China
| |
Collapse
|
35
|
Ye D, Sun X, Zhang C, Zhang S, Zhang X, Wang S, Fu W. In Vivo Foot and Ankle Kinematics During Activities Measured by Using a Dual Fluoroscopic Imaging System: A Narrative Review. Front Bioeng Biotechnol 2021; 9:693806. [PMID: 34350162 PMCID: PMC8327092 DOI: 10.3389/fbioe.2021.693806] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Accepted: 07/05/2021] [Indexed: 12/26/2022] Open
Abstract
Foot and ankle joints are complicated anatomical structures that combine the tibiotalar and subtalar joints. They play an extremely important role in walking, running, jumping and other dynamic activities of the human body. The in vivo kinematic analysis of the foot and ankle helps deeply understand the movement characteristics of these structures, as well as identify abnormal joint movements and treat related diseases. However, the technical deficiencies of traditional medical imaging methods limit studies on in vivo foot and ankle biomechanics. During the last decade, the dual fluoroscopic imaging system (DFIS) has enabled the accurate and noninvasive measurements of the dynamic and static activities in the joints of the body. Thus, this method can be utilised to quantify the movement in the single bones of the foot and ankle and analyse different morphological joints and complex bone positions and movement patterns within these organs. Moreover, it has been widely used in the field of image diagnosis and clinical biomechanics evaluation. The integration of existing single DFIS studies has great methodological reference value for future research on the foot and ankle. Therefore, this review evaluated existing studies that applied DFIS to measure the in vivo kinematics of the foot and ankle during various activities in healthy and pathologic populations. The difference between DFIS and traditional biomechanical measurement methods was shown. The advantages and shortcomings of DFIS in practical application were further elucidated, and effective theoretical support and constructive research direction for future studies on the human foot and ankle were provided.
Collapse
Affiliation(s)
- Dongqiang Ye
- School of Kinesiology, Shanghai University of Sport, Shanghai, China
| | - Xiaole Sun
- School of Kinesiology, Shanghai University of Sport, Shanghai, China
| | - Cui Zhang
- School of Kinesiology, Shanghai University of Sport, Shanghai, China.,Shandong Institute of Sport Science, Jinan, China
| | - Shen Zhang
- School of Kinesiology, Shanghai University of Sport, Shanghai, China
| | - Xini Zhang
- School of Kinesiology, Shanghai University of Sport, Shanghai, China
| | - Shaobai Wang
- School of Kinesiology, Shanghai University of Sport, Shanghai, China
| | - Weijie Fu
- School of Kinesiology, Shanghai University of Sport, Shanghai, China.,Key Laboratory of Exercise and Health Sciences of Ministry of Education, Shanghai University of Sport, Shanghai, China
| |
Collapse
|
36
|
Aliaj K, Foreman KB, Chalmers PN, Henninger HB. Beyond Euler/Cardan analysis: True glenohumeral axial rotation during arm elevation and rotation. Gait Posture 2021; 88:28-36. [PMID: 33989999 PMCID: PMC8316370 DOI: 10.1016/j.gaitpost.2021.05.004] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2021] [Revised: 04/09/2021] [Accepted: 05/03/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND Based on Euler/Cardan analysis, prior investigations have reported up to 80° of glenohumeral (GH) external rotation during arm elevation, dependent on the plane of elevation (PoE). However, the subtraction of Euler/Cardan angles does not compute the rotation around the humerus' longitudinal axis (i.e. axial rotation). Clinicians want to understand the true rotation around the humerus' longitudinal axis and rely on laboratories to inform their understanding of underlying shoulder biomechanics, especially for the GH joint since its motion cannot be visually ascertained. True GH axial rotation has not been previously measured in vivo, and its difference from Euler/Cardan (apparent) axial rotation is unknown. RESEARCH QUESTION What is the true GH axial rotation during arm elevation and external rotation, and does it vary from apparent axial rotation and by PoE? METHODS Twenty healthy subjects (10 M/10 F, ages 22-66) were recorded using biplane fluoroscopy while performing arm elevation in the coronal, scapular and sagittal planes, and external rotation in 0° and 90° of abduction. Apparent GH axial rotation was computed using the xz'y'' and yx'y'' sequences. True GH axial rotation was computed by integrating the projection of GH angular velocity onto the humerus' longitudinal axis. One-dimensional statistical parametric mapping was utilized to compare apparent versus true axial rotation, axial rotation versus 0°, and detect differences in axial rotation by PoE. RESULTS In contrast to apparent axial rotation, true GH axial rotation does not differ by PoE and is not different than 0° during arm elevation at higher elevation angles. The spherical area between the sequence-specific and actual humeral trajectory explains the difference between apparent and true axial rotation. SIGNIFICANCE Proper quantification of axial rotation is important because biomechanics literature informs clinical understanding of shoulder biomechanics. Clinicians care about true axial rotation, which should be reported in future studies of shoulder kinematics.
Collapse
Affiliation(s)
- Klevis Aliaj
- Department of Orthopaedics, University of Utah, Salt Lake City, UT,Department of Biomedical Engineering, University of Utah, Salt Lake City, UT
| | - K. Bo Foreman
- Department of Orthopaedics, University of Utah, Salt Lake City, UT,Department of Physical Therapy and Athletic Training, University of Utah, Salt Lake City, UT
| | | | - Heath B. Henninger
- Department of Orthopaedics, University of Utah, Salt Lake City, UT,Department of Biomedical Engineering, University of Utah, Salt Lake City, UT,Department of Mechanical Engineering, University of Utah, Salt Lake City, UT
| |
Collapse
|
37
|
Graft healing does not influence subjective outcomes and shoulder kinematics after superior capsule reconstruction: a prospective in vivo kinematic study. J Shoulder Elbow Surg 2021; 30:S48-S56. [PMID: 33775820 DOI: 10.1016/j.jse.2021.02.026] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Revised: 02/28/2021] [Accepted: 02/28/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND A viable treatment option for young patients with massive, irreparable rotator cuff tears is arthroscopic superior capsule reconstruction (SCR). SCR theoretically improves shoulder stability and function and decreases pain. However, no prospective studies to date have correlated magnetic resonance imaging (MRI) healing with in vivo kinematic data. The purpose of this study was to evaluate the association between graft healing and in vivo kinematics, range of motion (ROM), strength, and patient-reported outcomes (PROs). METHODS Ten patients (8 men and 2 women; mean age, 63 ± 7 years) with irreparable rotator cuff tears underwent arthroscopic SCR with dermal allograft. Strength was measured with isometric internal rotation and external rotation (ER) at 0° of abduction, ER at 90° of abduction, and scapular-plane abduction, whereas ROM was measured during shoulder flexion, abduction, and ER and internal rotation at 90° of abduction both before and 1 year after SCR. PROs included American Shoulder and Elbow Surgeons, Western Ontario Rotator Cuff Index, and Disabilities of the Arm, Shoulder and Hand surveys that were collected before and 1 year after SCR. Synchronized biplane radiographs were collected at 50 images/s before and 1 year after SCR while patients performed 3 trials of scapular-plane abduction. A validated volumetric tracking technique with submillimeter accuracy determined 6-df glenohumeral and scapular kinematics. The acromiohumeral distance (AHD), humeral head translation, and scapulohumeral rhythm (SHR) were calculated from the in vivo kinematics. Healing at 5 locations was evaluated on 1-year postoperative MRI scans: anterior and posterior glenoid, anterior and posterior humerus, and posteriorly along the infraspinatus. Each subject was given a score from 0 to 5 based on number of sites healed. RESULTS Of the 10 patients, 9 (90%) had complete (n = 4) or partial (n = 5) healing of the graft whereas 1 (10%) had complete failure at the glenoid. No correlation existed between MRI healing and the AHD, SHR, strength, ROM, or PROs. American Shoulder and Elbow Surgeons, Western Ontario Rotator Cuff Index, and Disabilities of the Arm, Shoulder and Hand scores all significantly improved from before to 1 year after SCR regardless of graft healing. CONCLUSIONS The rate of complete or partial graft healing on MRI mimics findings of prior reports in the literature. MRI healing was correlated with humeral head anterior-posterior translation but not with the static and dynamic AHDs, SHR, humeral head superior-inferior translation, ROM, strength, or PROs 1 year after SCR. All PROs improved significantly from before to 1 year after SCR regardless of graft status on MRI. In vivo kinematic changes were small after SCR and not clinically significant, and the data suggest that improvements in clinical and functional outcomes may occur in the absence of full graft healing.
Collapse
|
38
|
Akhbari B, Shah KN, Morton AM, Moore DC, Weiss APC, Wolfe SW, Crisco JJ. Biomechanics of the Distal Radioulnar Joint During In Vivo Forearm Pronosupination. J Wrist Surg 2021; 10:208-215. [PMID: 34109063 PMCID: PMC8169167 DOI: 10.1055/s-0040-1722334] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Accepted: 11/12/2020] [Indexed: 10/22/2022]
Abstract
Background Ulnar variance (UV) and center of rotation (COR) location at the level of the distal radioulnar joint (DRUJ) change with forearm rotation. Nevertheless, these parameters have not been assessed dynamically during active in vivo pronosupination. This assessment could help us to improve our diagnosis and treatment strategies. Questions/purposes We sought to (1) mathematically model the UV change, and (2) determine the dynamic COR's location during active pronosupination. Methods We used biplanar videoradiography to study DRUJ during in vivo pronation and supination in nine healthy subjects. UV was defined as the proximal-distal distance of ulnar fovea with respect to the radial sigmoid notch, and COR was calculated using helical axis of motion parameters. The continuous change of UV was evaluated using a generalized linear regression model. Results A second-degree polynomial with R 2 of 0.85 was able to model the UV changes. Maximum negative UV occurred at 38.0 degrees supination and maximum positive UV occurred at maximum pronation. At maximum pronation, the COR was located 0.5 ± 1.8 mm ulnarly and 0.6 ± 0.8 mm volarly from the center of the ulnar fovea, while at maximum supination, the COR was located 0.2 ± 0.6 mm radially and 2.0 ± 0.5 mm volarly. Conclusion Changes in UV and volar translation of the COR are nonlinear at the DRUJ during pronosupination. Clinical Relevance Understanding the dynamic nature of UV as a function of pronosupination can help guide accurate evaluation and treatment of wrist pathology where the UV is an important consideration. The dynamic behavior of COR might be useful in designing DRUJ replacement implants to match the anatomical motion.
Collapse
Affiliation(s)
- Bardiya Akhbari
- Center for Biomedical Engineering, Brown University, Providence, Rhode Island
| | - Kalpit N. Shah
- Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, Rhode Island
| | - Amy M. Morton
- Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, Rhode Island
| | - Douglas C. Moore
- Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, Rhode Island
| | - Arnold-Peter C. Weiss
- Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, Rhode Island
- Division of Hand, Upper Extremity & Microvascular Surgery, Department of Orthopaedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, Rhode Island
| | - Scott W. Wolfe
- Hand and Upper Extremity Center, Hospital for Special Surgery, New York, New York
- Department of Orthopaedic Surgery, Weill Medical College of Cornell University, New York, New York
| | - Joseph J. Crisco
- Center for Biomedical Engineering, Brown University, Providence, Rhode Island
- Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, Rhode Island
| |
Collapse
|
39
|
Lawrence RL, Zauel R, Bey MJ. Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography. J Vis Exp 2021. [PMID: 33779606 DOI: 10.3791/62210] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023] Open
Abstract
The shoulder is one of the human body's most complex joint systems, with motion occurring through the coordinated actions of four individual joints, multiple ligaments, and approximately 20 muscles. Unfortunately, shoulder pathologies (e.g., rotator cuff tears, joint dislocations, arthritis) are common, resulting in substantial pain, disability, and decreased quality of life. The specific etiology for many of these pathologic conditions is not fully understood, but it is generally accepted that shoulder pathology is often associated with altered joint motion. Unfortunately, measuring shoulder motion with the necessary level of accuracy to investigate motion-based hypotheses is not trivial. However, radiographic-based motion measurement techniques have provided the advancement necessary to investigate motion-based hypotheses and provide a mechanistic understanding of shoulder function. Thus, the purpose of this article is to describe the approaches for measuring shoulder motion using a custom biplanar videoradiography system. The specific objectives of this article are to describe the protocols to acquire biplanar videoradiographic images of the shoulder complex, acquire CT scans, develop 3D bone models, locate anatomical landmarks, track the position and orientation of the humerus, scapula, and torso from the biplanar radiographic images, and calculate the kinematic outcome measures. In addition, the article will describe special considerations unique to the shoulder when measuring joint kinematics using this approach.
Collapse
Affiliation(s)
- Rebekah L Lawrence
- Bone and Joint Center, Department of Orthopaedic Surgery, Henry Ford Health System
| | - Roger Zauel
- Bone and Joint Center, Department of Orthopaedic Surgery, Henry Ford Health System
| | - Michael J Bey
- Bone and Joint Center, Department of Orthopaedic Surgery, Henry Ford Health System;
| |
Collapse
|
40
|
Roach KE, Foreman KB, MacWilliams BA, Karpos K, Nichols J, Anderson AE. The modified Shriners Hospitals for Children Greenville (mSHCG) multi-segment foot model provides clinically acceptable measurements of ankle and midfoot angles: A dual fluoroscopy study. Gait Posture 2021; 85:258-265. [PMID: 33626450 PMCID: PMC8085108 DOI: 10.1016/j.gaitpost.2021.02.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Revised: 09/28/2020] [Accepted: 02/05/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND Several multi-segment foot models have been developed to evaluate foot and ankle motion using skin-marker motion analysis. However, few multi-segment models have been evaluated against a reference standard to establish kinematic accuracy. RESEARCH QUESTION How accurately do skin-markers estimate foot and ankle motion for the modified Shriners Hospitals for Children Greenville (mSHCG) multi-segment foot model when compared against the reference standard, dual fluoroscopy (DF), during gait, in asymptomatic participants? METHODS Five participants walked overground as full-body skin-marker trajectory data and DF images of the foot and shank were simultaneously acquired. Using the mSHCG model, ankle and midfoot angles were calculated throughout stance for both motion analysis techniques. Statistical parametric mapping assessed differences in joint angles and marker positions between skin-marker and DF motion analysis techniques. Paired t tests, and linear regression models were used to compare joint angles and range of motion (ROM) calculated from the two techniques. RESULTS In the coronal plane, the skin-marker model significantly overestimated ROM (p = 0.028). Further, the DF model midfoot ROM was significantly positively related to differences between DF and skin-marker midfoot angles (p = 0.035, adjusted R2 = 0.76). In the sagittal plane, skin-markers underestimated ankle angles by as much as 7.26°, while midfoot angles were overestimated by as much as 9.01°. However, DF and skin-marker joint angles were not significantly different over stance. Skin-markers on the tibia, calcaneus, and fifth metatarsal had significantly different positions than the DF markers along the direction of walking for isolated portions that were less than 10 % of stance. Euclidean distances between DF and skin-markers positions were less than 9.36 mm. SIGNIFICANCE As the accuracy of the mSHCG model was formerly unknown, the results of this study provide ranges of confidence for key angles calculated by this model.
Collapse
Affiliation(s)
- Koren E. Roach
- Department of Radiology and Biomedical Imaging, 185 Berry St., Suite 350, San Francisco, CA 94107,Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT 84108,Department of Biomedical Engineering, University of Utah, 72 Central Campus Dr, Salt Lake City, UT 84112
| | - K. Bo Foreman
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT 84108,Department of Physical Therapy and Athletic Training, University of Utah, 520 Wakara Way, Suite 240, Salt Lake City, UT 84108
| | - Bruce A. MacWilliams
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT 84108,Motion Analysis Center, Shriners Hospitals for Children, 1275 Fairfax Rd., Salt Lake City, UT 84103, USA
| | - Kostantino Karpos
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT 84108,Department of Physics, Arizona State University, 550 E Tyler Drive Tempe, AZ 85287
| | - Jennifer Nichols
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT 84108,J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, 1275 Center Drive, Gainesville, FL 32611
| | - Andrew E. Anderson
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT 84108,Department of Biomedical Engineering, University of Utah, 72 Central Campus Dr, Salt Lake City, UT 84112,Department of Physical Therapy and Athletic Training, University of Utah, 520 Wakara Way, Suite 240, Salt Lake City, UT 84108,Scientific Computing and Imaging Institute, University of Utah, 72 Central Campus Dr, Salt Lake City, UT 84112
| |
Collapse
|
41
|
Akhbari B, Morton AM, Moore DC, Crisco JJ. Biplanar Videoradiography to Study the Wrist and Distal Radioulnar Joints. J Vis Exp 2021:10.3791/62102. [PMID: 33616093 PMCID: PMC8182367 DOI: 10.3791/62102] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023] Open
Abstract
Accurate measurement of skeletal kinematics in vivo is essential for understanding normal joint function, the influence of pathology, disease progression, and the effects of treatments. Measurement systems that use skin surface markers to infer skeletal motion have provided important insight into normal and pathological kinematics, however, accurate arthrokinematics cannot be attained using these systems, especially during dynamic activities. In the past two decades, biplanar videoradiography (BVR) systems have enabled many researchers to directly study the skeletal kinematics of the joints during activities of daily living. To implement BVR systems for the distal upper extremity, videoradiographs of the distal radius and the hand are acquired from two calibrated X-ray sources while a subject performs a designated task. Three-dimensional (3D) rigid-body positions are computed from the videoradiographs via a best-fit registrations of 3D model projections onto to each BVR view. The 3D models are density-based image volumes of the specific bone derived from independently acquired computed-tomography data. Utilizing graphics processor units and high-performance computing systems, this model-based tracking approach is shown to be fast and accurate in evaluating the wrist and distal radioulnar joint biomechanics. In this study, we first summarized the previous studies that have established the submillimeter and subdegree agreement of BVR with an in vitro optical motion capture system in evaluating the wrist and distal radioulnar joint kinematics. Furthermore, we used BVR to compute the center of rotation behavior of the wrist joint, to evaluate the articulation pattern of the components of the implant upon one another, and to assess the dynamic change of ulnar variance during pronosupination of the forearm. In the future, carpal bones may be captured in greater detail with the addition of flat panel X-ray detectors, more X-ray sources (i.e., multiplanar videoradiography), or advanced computer vision algorithms.
Collapse
Affiliation(s)
| | - Amy M Morton
- Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital
| | - Douglas C Moore
- Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital
| | - Joseph J Crisco
- Center for Biomedical Engineering, Brown University; Department of Orthopedics, The Warren Alpert Medical School of Brown University and Rhode Island Hospital
| |
Collapse
|
42
|
Kolz CW, Sulkar HJ, Aliaj K, Tashjian RZ, Chalmers PN, Qiu Y, Zhang Y, Bo Foreman K, Anderson AE, Henninger HB. Age-related differences in humerothoracic, scapulothoracic, and glenohumeral kinematics during elevation and rotation motions. J Biomech 2021; 117:110266. [PMID: 33517243 PMCID: PMC7924070 DOI: 10.1016/j.jbiomech.2021.110266] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Revised: 11/25/2020] [Accepted: 01/16/2021] [Indexed: 11/26/2022]
Abstract
Age affects gross shoulder range of motion (ROM), but biomechanical changes over a lifetime are typically only characterized for the humerothoracic joint. Suitable age-related baselines for the scapulothoracic and glenohumeral contributions to humerothoracic motion are needed to advance understanding of shoulder injuries and pathology. Notably, biomechanical comparisons between younger or older populations may obscure detected differences in underlying shoulder motion. Herein, biplane fluoroscopy and skin-marker motion analysis quantified humerothoracic, scapulothoracic, and glenohumeral motion during 3 static poses (resting neutral, internal rotation to L4-L5, and internal rotation to maximum reach) and 2 dynamic activities (scapular plane abduction and external rotation in adduction). Orientations during static poses and rotations during active ROM were compared between subjects <35 years and >45 years of age (N=10 subjects per group). Numerous age-related kinematic differences were measured, ranging 5–25°, where variations in scapular orientation and motion were consistently observed. These disparities are on par with or exceed mean clinically important differences and standard error of measurement of clinical ROM, which indicates that high resolution techniques and appropriately matched controls are required to avoid confounding results of studies that investigate shoulder kinematics. Understanding these dissimilarities will help clinicians manage expectations and treatment protocols where indications and prevalence between age groups tend to differ. Where possible, it is advised to select age-matched control cohorts when studying the kinematics of shoulder injury, pathology, or surgical/physical therapy interventions to ensure clinically important differences are not overlooked.
Collapse
Affiliation(s)
- Christopher W Kolz
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, United States; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States
| | - Hema J Sulkar
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, United States; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States
| | - Klevis Aliaj
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, United States; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States
| | - Robert Z Tashjian
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, United States
| | - Peter N Chalmers
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, United States
| | - Yuqing Qiu
- Department of Epidemiology, University of Utah, Salt Lake City, UT, United States
| | - Yue Zhang
- Department of Epidemiology, University of Utah, Salt Lake City, UT, United States
| | - K Bo Foreman
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, United States; Department of Physical Therapy and Athletic Training, University of Utah, Salt Lake City, UT, United States
| | - Andrew E Anderson
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, United States; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States; Department of Physical Therapy and Athletic Training, University of Utah, Salt Lake City, UT, United States
| | - Heath B Henninger
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, United States; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States.
| |
Collapse
|
43
|
Errors in Measuring Glenohumeral Arthrokinematics With 2-Dimensional Fluoroscopy. J Appl Biomech 2021; 37:282-287. [PMID: 33485271 DOI: 10.1123/jab.2020-0098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Revised: 09/26/2020] [Accepted: 11/18/2020] [Indexed: 11/18/2022]
Abstract
Two-dimensional fluoroscopic imaging allows measurement of small magnitude humeral head translations that are prone to errors due to optical distortion, out-of-plane imaging, repeated manual identification of landmarks, and magnification. This article presents results from in vivo and in vitro fluoroscopy-based experiments that measure the errors and variability in estimating the humeral head translated position in true scapular plane and axillary views. The errors were expressed as bias and accuracy. The variability with repeated digitization was calculated using the intraclass correlation coefficient (ICC) and the standard error of measurement. Optical distortion caused underestimation of linear distances. The accuracy was 0.11 and 0.43 mm for in vitro and in vivo experiments, respectively, for optical distortion. The intrarater reliability was excellent for both views (ICC = .94 and .93), and interrater reliability was excellent (ICC = .95) for true scapular view but moderate (ICC = .74) for axillary views. The standard error of measurement ranged from 0.27 to 0.58 mm. The accuracy for the humeral head position in 10° out of true scapular plane images ranged from 0.80 to 0.87 mm. The current study quantifies the magnitude of error. The results suggest that suitable measures could be incorporated to minimize errors and variability for the measurement of glenohumeral parameters.
Collapse
|
44
|
Abstract
X-Ray Reconstruction of Moving Morphology (XROMM), though traditionally used for studies of in vivo skeletal kinematics, can also be used to precisely and accurately measure ex vivo range of motion from cadaveric manipulations. The workflow for these studies is holistically similar to the in vivo XROMM workflow but presents several unique challenges. This paper aims to serve as a practical guide by walking through each step of the ex vivo XROMM process: how to acquire and prepare cadaveric specimens, how to manipulate specimens to collect X-ray data, and how to use these data to compute joint rotational mobility. Along the way, it offers recommendations for best practices and for avoiding common pitfalls to ensure a successful study.
Collapse
Affiliation(s)
- Armita R Manafzadeh
- Department of Ecology and Evolutionary Biology, Brown University, Providence, RI 02912, USA
| |
Collapse
|
45
|
Gale T, Anderst W. Knee Kinematics of Healthy Adults Measured Using Biplane Radiography. J Biomech Eng 2020; 142:1084204. [PMID: 32491153 DOI: 10.1115/1.4047419] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Indexed: 11/08/2022]
Abstract
A dataset of knee kinematics in healthy, uninjured adults is needed to serve as a reference for comparison when evaluating the effects of injury, surgery, rehabilitation, and age. Most currently available datasets that characterize healthy knee kinematics were developed using conventional motion analysis, known to suffer from skin motion artifact. More accurate kinematics, obtained from bone pins or biplane radiography, have been reported for datasets ranging in size from 5 to 15 knees. The aim of this study was to characterize tibiofemoral kinematics and its variability in a larger sample of healthy adults. Thirty-nine knees were imaged using biplane radiography at 100 images/s during multiple trials of treadmill walking. Multiple gait trials were captured to measure stance and swing-phase knee kinematics. Six degrees-of-freedom kinematics were determined using a validated volumetric model-based tracking process. A bootstrapping technique was used to define average and 90% prediction bands for the kinematics. The average ROM during gait was 7.0 mm, 3.2 mm, and 2.9 mm in anterior/posterior (AP), medial/lateral (ML), and proximal/distal (PD) directions, and 67.3 deg, 11.5 deg, and 3.7 deg in flexion/extension (FE), internal/external (IE), and abduction/adduction (AbAd). Continuous kinematics demonstrated large interknee variability, with 90% prediction bands spanning approximately ±4 mm, ±10 mm, and ±5 mm for ML, AP, and PD translations and ±15 deg, ±10 deg, and ±6 deg in FE, IE, and AbAd. This dataset suggests substantial variability exists in healthy knee kinematics. This study provides a normative database for evaluating knee kinematics in patients who receive conservative or surgical treatment.
Collapse
Affiliation(s)
- Tom Gale
- Biodynamics Lab, Department of Orthopaedic Surgery, University of Pittsburgh, 3820 South Water Street, Pittsburgh, PA 15203
| | - William Anderst
- Biodynamics Lab, Department of Orthopaedic Surgery, University of Pittsburgh, 3820 South Water Street, Pittsburgh, PA 15203
| |
Collapse
|
46
|
Kolz CW, Sulkar HJ, Aliaj K, Tashjian RZ, Chalmers PN, Qiu Y, Zhang Y, Foreman KB, Anderson AE, Henninger HB. Reliable interpretation of scapular kinematics depends on coordinate system definition. Gait Posture 2020; 81:183-190. [PMID: 32758918 PMCID: PMC7484087 DOI: 10.1016/j.gaitpost.2020.07.020] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Revised: 07/09/2020] [Accepted: 07/20/2020] [Indexed: 02/02/2023]
Abstract
BACKGROUND Interpretation of shoulder motion across studies has been complicated due to the use of numerous scapular coordinate systems in the literature. Currently, there are no simple means by which to compare scapular kinematics between coordinate system definitions when data from only one coordinate system is known. RESEARCH QUESTION How do scapular kinematics vary based on the choice of coordinate system and can average rotation matrices be used to accurately convert kinematics between scapular local coordinate systems? METHODS Average rotation matrices derived from anatomic landmarks of 51 cadaver scapulae (29 M/22 F; 59 ± 13 yrs; 26R/25 L; 171 ± 11 cm; 70 ± 19 kg; 23.7 ± 5.5 kg/m2) were generated between three common scapular coordinate systems. Absolute angle of rotation was used to determine if anatomical variability within the cadaver population influenced the matrices. To quantify the predictive capability to convert kinematics between the three coordinate systems, the average rotation matrices were applied to scapulothoracic motion data collected from 19 human subjects (10 M/9 F; 43 ± 17 yrs; 19R; 173 ± 9 cm; 71 ± 16 kg; 23.6 ± 4.5 kg/m2) using biplane fluoroscopy. Root mean squared error (RMSE) was used to compare kinematics from an original coordinate system to the kinematics expressed in each alternative coordinate system. RESULTS The choice of scapular coordinate system resulted in mean differences in scapulothoracic rotation of up to 23°, with overall different shapes and/or magnitudes of the curves. A single average rotation matrix between any two coordinate systems achieved accurate conversion of scapulothoracic kinematics to within 4° of RMSE of the known solution. The average rotation matrices were independent of sex, side, decomposition sequence, and motion. SIGNIFICANCE Scapulothoracic kinematic representations vary in shape and magnitude based solely on the choice of local coordinate system. The results of this study enhance interpretability and reproducibility in expressing scapulothoracic motion data between laboratories by providing a simple means to convert data between common coordinate systems. This is necessitated by the variety of available motion analysis techniques and their respective scapular landmark definitions.
Collapse
Affiliation(s)
- Christopher W Kolz
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, United States; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States
| | - Hema J Sulkar
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, United States; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States
| | - Klevis Aliaj
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, United States; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States
| | - Robert Z Tashjian
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, United States
| | - Peter N Chalmers
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, United States
| | - Yuqing Qiu
- Department of Epidemiology, University of Utah, Salt Lake City, UT, United States
| | - Yue Zhang
- Department of Epidemiology, University of Utah, Salt Lake City, UT, United States
| | - K Bo Foreman
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, United States; Department of Physical Therapy and Athletic Training, University of Utah, Salt Lake City, UT, United States
| | - Andrew E Anderson
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, United States; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States; Department of Physical Therapy and Athletic Training, University of Utah, Salt Lake City, UT, United States
| | - Heath B Henninger
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, United States; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States.
| |
Collapse
|
47
|
Lawrence RL, Ruder MC, Zauel R, Bey MJ. Instantaneous helical axis estimation of glenohumeral kinematics: The impact of rotator cuff pathology. J Biomech 2020; 109:109924. [PMID: 32807327 PMCID: PMC7443981 DOI: 10.1016/j.jbiomech.2020.109924] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2019] [Revised: 05/02/2020] [Accepted: 06/21/2020] [Indexed: 11/16/2022]
Abstract
The rotator cuff is theorized to contribute to force couples required to produce glenohumeral kinematics. Impairment in these force couples would theoretically result in impaired ball-and-socket kinematics. Although less frequently used than traditional kinematic descriptors (e.g., Euler angles, joint translations), helical axes are capable of identifying alterations in ball-and-socket kinematics by quantifying the variability (i.e., dispersion) in axis orientation and position during motion. Consequently, assessing glenohumeral helical dispersion may provide indirect evidence of rotator cuff function. The purpose of this exploratory study was to determine the extent to which rotator cuff pathology is associated with alterations in ball-and-socket kinematics. Fifty-one participants were classified into one of five groups based on an assessment of the supraspinatus using diagnostic imaging: asymptomatic healthy, asymptomatic tendinosis, asymptomatic partial-thickness tear, asymptomatic full-thickness tear, symptomatic full-thickness tear. Glenohumeral kinematics were quantified during coronal plane abduction using a biplane x-ray system and described using instantaneous helical axes. The degree to which glenohumeral motion coincided with ball-and-socket kinematics was described using the angular and positional dispersion about the optimal helical axis and pivot, respectively. No statistically significant difference was observed between groups in angular dispersion. However, symptomatic individuals with a full-thickness supraspinatus tear had significantly more positional dispersion than asymptomatic individuals with a healthy supraspinatus or tendinosis. These findings suggest that symptomatic individuals with a full-thickness supraspinatus tear exhibit impaired ball-and-socket kinematics, which is believed to be associated with a disruption of the glenohumeral force couples.
Collapse
Affiliation(s)
- Rebekah L Lawrence
- Bone and Joint Center, Department of Orthopaedic Surgery, Henry Ford Health System, 6135 Woodward Avenue, Detroit, MI 48202, USA.
| | - Matthew C Ruder
- Bone and Joint Center, Department of Orthopaedic Surgery, Henry Ford Health System, 6135 Woodward Avenue, Detroit, MI 48202, USA
| | - Roger Zauel
- Bone and Joint Center, Department of Orthopaedic Surgery, Henry Ford Health System, 6135 Woodward Avenue, Detroit, MI 48202, USA
| | - Michael J Bey
- Bone and Joint Center, Department of Orthopaedic Surgery, Henry Ford Health System, 6135 Woodward Avenue, Detroit, MI 48202, USA
| |
Collapse
|
48
|
Lee EC, Roach NT, Clouthier AL, Bicknell RT, Bey MJ, Young NM, Rainbow MJ. Three-dimensional scapular morphology is associated with rotator cuff tears and alters the abduction moment arm of the supraspinatus. Clin Biomech (Bristol, Avon) 2020; 78:105091. [PMID: 32580097 PMCID: PMC8161464 DOI: 10.1016/j.clinbiomech.2020.105091] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2020] [Revised: 04/29/2020] [Accepted: 06/09/2020] [Indexed: 02/07/2023]
Abstract
BACKGROUND Numerous studies have reported an association between rotator cuff injury and two-dimensional measures of scapular morphology. However, the mechanical underpinnings explaining how these shape features affect glenohumeral joint function and lead to injury are poorly understood. We hypothesized that three-dimensional features of scapular morphology differentiate asymptomatic shoulders from those with rotator cuff tears, and that these features would alter the mechanical advantage of the supraspinatus. METHODS Twenty-four individuals with supraspinatus tears and twenty-seven age-matched controls were recruited. A statistical shape analysis identified scapular features distinguishing symptomatic patients from asymptomatic controls. We examined the effect of injury-associated morphology on mechanics by developing a morphable model driven by six degree-of-freedom biplanar videoradiography data. We used the model to simulate abduction for a range of shapes and computed the supraspinatus moment arm. FINDINGS Rotator cuff injury was associated with a cranial orientation of the glenoid and scapular spine (P = .011, d = 0.75) and/or decreased subacromial space (P = .001, d = 0.94). The shape analysis also identified previously undocumented features associated with superior inclination and subacromial narrowing. In our computational model, warping the scapula from a cranial to a lateral orientation increased the supraspinatus moment arm at 20° of abduction and decreased the moment arm at 160° of abduction. INTERPRETATIONS Three-dimensional analysis of scapular morphology indicates a stronger relationship between morphology and cuff tears than two-dimensional measures. Insight into how morphological features affect rotator cuff mechanics may improve patient-specific strategies for prevention and treatment of cuff tears.
Collapse
Affiliation(s)
- Erin C.S. Lee
- Department of Mechanical and Materials Engineering, Queen’s University, Kingston, ON, Canada,Corresponding author at: Department of Mechanical and Materials Engineering and Human Mobility Research Centre, Queen’s University, 130 Stuart Street, Kingston, ON K7L 3N6, Canada., (E.C.S. Lee)
| | - Neil T. Roach
- Department of Human Evolutionary Biology, Harvard University, Cambridge, MA, USA
| | | | - Ryan T. Bicknell
- Department of Surgery, Kingston Health Sciences Centre, Kingston, Canada
| | - Michael J. Bey
- Department of Orthopaedic Surgery, Henry Ford Hospital, Detroit, MI, USA
| | - Nathan M. Young
- Department of Orthopaedic Surgery, University of California San Francisco, CA, USA
| | - Michael J. Rainbow
- Department of Mechanical and Materials Engineering, Queen’s University, Kingston, ON, Canada
| |
Collapse
|
49
|
Fiorentino NM, Atkins PR, Kutschke MJ, Bo Foreman K, Anderson AE. Soft tissue artifact causes underestimation of hip joint kinematics and kinetics in a rigid-body musculoskeletal model. J Biomech 2020; 108:109890. [PMID: 32636003 PMCID: PMC7405358 DOI: 10.1016/j.jbiomech.2020.109890] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2019] [Revised: 05/22/2020] [Accepted: 06/09/2020] [Indexed: 10/24/2022]
Abstract
Rigid body musculoskeletal models have been applied to study kinematics, moments, muscle forces, and joint reaction forces in the hip. Most often, models are driven with segment motions calculated through optical tracking of markers adhered to the skin. One limitation of optical tracking is soft tissue artifact (STA), which occurs due to motion of the skin surface relative to the underlying skeleton. The purpose of this study was to quantify differences in musculoskeletal model outputs when tracking body segment positions with skin markers as compared to bony landmarks measured by direct imaging of bone motion with dual fluoroscopy (DF). Eleven asymptomatic participants with normally developed hip anatomy were imaged with DF during level treadmill walking at a self-selected speed. Hip joint kinematics and kinetics were generated using inverse kinematics, inverse dynamics, static optimization and joint reaction force analysis. The effect of STA was assessed by comparing the difference in estimates from simulations based on skin marker positions (SM) versus virtual markers on bony landmarks from DF. While patterns were similar, STA caused underestimation of kinematics, range of motion (ROM), moments, and reaction forces at the hip, including flexion-extension ROM, maximum internal rotation joint moment and peak joint reaction force magnitude. Still, kinetic differences were relatively small, and thus they may not be relevant nor clinically meaningful.
Collapse
Affiliation(s)
- Niccolo M Fiorentino
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT 84108, USA; Department of Mechanical Engineering, University of Vermont, 33 Colchester Ave, Burlington, VT 05403, USA
| | - Penny R Atkins
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT 84108, USA; Department of Bioengineering, University of Utah, 36 S. Wasatch Drive, Room 3100, Salt Lake City, UT 84112, USA
| | - Michael J Kutschke
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT 84108, USA
| | - K Bo Foreman
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT 84108, USA; Department of Physical Therapy, University of Utah, 520 Wakara Way, Suite 240, Salt Lake City, UT 84108, USA
| | - Andrew E Anderson
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT 84108, USA; Department of Bioengineering, University of Utah, 36 S. Wasatch Drive, Room 3100, Salt Lake City, UT 84112, USA; Scientific Computing and Imaging Institute, University of Utah, 72 S. Central Campus Drive, Room 3750, Salt Lake City, UT 84112, USA.
| |
Collapse
|
50
|
Lee D, Hong KT, Lim TS, Lee E, Lee YH, Park JS, Kim W, Oh JH, Choi JA, Song Y. Alterations in articular cartilage T2 star relaxation time following mechanical disorders: in vivo canine supraspinatus tendon resection models. BMC Musculoskelet Disord 2020; 21:424. [PMID: 32615950 PMCID: PMC7331159 DOI: 10.1186/s12891-020-03447-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Accepted: 06/23/2020] [Indexed: 11/10/2022] Open
Abstract
Background The role of altered joint mechanics on cartilage degeneration in in vivo models has not been studied successfully due to a lack of pre-injury information. We aimed 1) to develop an accurate in vivo canine model to measure the changes in joint loading and T2 star (T2*) relaxation time before and after unilateral supraspinatus tendon resections, and 2) to find the relationship between regional variations in articular cartilage loading patterns and T2* relaxation time distributions. Methods Rigid markers were implanted in the scapula and humerus of tested dogs. The movement of the shoulder bones were measured by a motion tracking system during normal gaits. In vivo cartilage contact strain was measured by aligning 3D shoulder models with the motion tracking data. Articular cartilage T2* relaxation times were measured by quantitative MRI scans. Articular cartilage contact strain and T2* relaxation time were compared in the shoulders before and 3 months after the supraspinatus tendon resections. Results Excellent accuracy and reproducibility were found in our in vivo contact strain measurements with less than 1% errors. Changes in articular cartilage contact strain exhibited similar patterns with the changes in the T2* relaxation time after resection surgeries. Regional changes in the articular cartilage T2* relaxation time exhibited positive correlations with regional contact strain variations 3 months after the supraspinatus resection surgeries. Conclusion This is the first study to measure in vivo articular cartilage contact strains with high accuracy and reproducibility. Positive correlations between contact strain and T2* relaxation time suggest that the articular cartilage extracellular matrix may responds to mechanical changes in local areas.
Collapse
Affiliation(s)
- Dokwan Lee
- Department of Mechanical Engineering, Korea University Engineering Campus, Innovation Hall, Room 306, Anam-dong, Seongbuk-gu, Seoul, 02841, South Korea
| | - Ki-Taek Hong
- Department of Mechanical Engineering, Korea University Engineering Campus, Innovation Hall, Room 306, Anam-dong, Seongbuk-gu, Seoul, 02841, South Korea
| | - Tae Seong Lim
- Department of Radiology, Gachon University Gil Medical Center, Incheon, South Korea
| | - Eugene Lee
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam, South Korea
| | - Ye Hyun Lee
- Department of Orthopedic Surgery, National Police Hospital, Seoul, South Korea
| | - Ji Soon Park
- Department of Orthopedic Surgery, Sheikh Khalifa Specialty Hospital, Ras Al Khaimah, United Arab Emirates
| | - Woo Kim
- Seoul Kiwoonchan Orthopedics Clinic, Seoul, South Korea
| | - Joo Han Oh
- Department of Orthopedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
| | - Jung-Ah Choi
- Department of Radiology, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, South Korea
| | - Yongnam Song
- Department of Mechanical Engineering, Korea University Engineering Campus, Innovation Hall, Room 306, Anam-dong, Seongbuk-gu, Seoul, 02841, South Korea.
| |
Collapse
|