1
|
Tuttle T, McClintock D, Roccabianca S. Effects of swelling and anatomical location on the viscoelastic behavior of the porcine urinary bladder wall. J Mech Behav Biomed Mater 2023; 143:105926. [PMID: 37269604 DOI: 10.1016/j.jmbbm.2023.105926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 05/18/2023] [Accepted: 05/21/2023] [Indexed: 06/05/2023]
Abstract
The ability of the urinary bladder to perform its physiological function depends largely on its mechanical characteristics. Understanding the mechanics of this tissue is crucial to the development of accurate models of not just this specific organ, but of the pelvic floor overall. In this study, we tested porcine bladder to identify variations in the tissue's viscoelastic characteristics associated with anatomical locations and swelling. We investigated this relationship using a series of stress-relaxation experiments as well as a modified Maxwell-Wiechert model to aid in the interpretation of the experimental data. Our results highlight that tissue located near the neck of the bladder presents significantly different viscoelastic characteristics than the body of the organ. This supports what was previously observed and is a valuable contribution to the understanding of the location-specific properties of the bladder. We also tested the effect of swelling, revealing that the bladder's viscoelastic behavior is mostly independent of solution osmolarity in hypoosmotic solutions, but the use of a hyperosmotic solution can significantly affect its behavior. This is significant, since several urinary tract pathologies can lead to chronic inflammation and disrupt the urothelial barrier causing increased urothelial permeability, thus subjecting the bladder wall to non-physiologic osmotic challenge.
Collapse
Affiliation(s)
- Tyler Tuttle
- Department of Mechanical Engineering, Michigan State University, East Lansing, MI, 48823, USA
| | - Dillon McClintock
- Department of Mechanical Engineering, Michigan State University, East Lansing, MI, 48823, USA
| | - Sara Roccabianca
- Department of Mechanical Engineering, Michigan State University, East Lansing, MI, 48823, USA.
| |
Collapse
|
2
|
Cheng F, Watton PN, Pederzani G, Kurobe M, Takaoka EI, Chapple C, Birder L, Yoshimura N, Robertson AM. A constrained mixture-micturition-growth (CMMG) model of the urinary bladder: Application to partial bladder outlet obstruction (BOO). J Mech Behav Biomed Mater 2022; 134:105337. [PMID: 35863296 PMCID: PMC9835014 DOI: 10.1016/j.jmbbm.2022.105337] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 04/13/2022] [Accepted: 06/24/2022] [Indexed: 01/14/2023]
Abstract
We present a constrained mixture-micturition-growth (CMMG) model for the bladder. It simulates bladder mechanics, voiding function (micturition) and tissue adaptations in response to altered biomechanical conditions. The CMMG model is calibrated with both in vivo and in vitro data from healthy male rat urinary bladders (cystometry, bioimaging of wall structure, mechanical testing) and applied to simulate the growth and remodeling (G&R) response to partial bladder outlet obstruction (BOO). The bladder wall is represented as a multi-layered, anisotropic, nonlinear constrained mixture. A short time scale micturition component of the CMMG model accounts for the active and passive mechanics of voiding. Over a second, longer time scale, G&R algorithms for the evolution of both cellular and extracellular constituents act to maintain/restore bladder (homeostatic) functionality. The CMMG model is applied to a spherical membrane model of the BOO bladder utilizing temporal data from an experimental male rodent model to parameterize and then verify the model. Consistent with the experimental studies of BOO, the model predicts: an initial loss of voiding capacity followed by hypertrophy of SMC to restore voiding function; bladder enlargement; collagen remodeling to maintain its role as a protective sheath; and increased voiding duration with lower average flow rate. This CMMG model enables a mechanistic approach for investigating the bladder's structure-function relationship and its adaption in pathological conditions. While the approach is illustrated with a conceptual spherical bladder model, it provides the basis for application of the CMMG model to anatomical geometries. Such a mechanistic approach has promise as an in silico tool for the rational development of new surgical and pharmacological treatments for bladder diseases such as BOO.
Collapse
Affiliation(s)
- Fangzhou Cheng
- Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, United States
| | - Paul N Watton
- Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, United States; Department of Computer Science & Insigneo Institute for in silico Medicine, University of Sheffield, Sheffield, United Kingdom.
| | - Giulia Pederzani
- Department of Computer Science & Insigneo Institute for in silico Medicine, University of Sheffield, Sheffield, United Kingdom
| | - Masahiro Kurobe
- Department of Urology, University of Pittsburgh, Pittsburgh, United States
| | - Ei-Ichiro Takaoka
- Department of Urology, University of Pittsburgh, Pittsburgh, United States
| | - Chris Chapple
- Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, United Kingdom
| | - Lori Birder
- Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, United Kingdom; Department of Medicine, University of Pittsburgh, United States
| | - Naoki Yoshimura
- Department of Urology, University of Pittsburgh, Pittsburgh, United States
| | - Anne M Robertson
- Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, United States
| |
Collapse
|
3
|
Tuttle TG, Lujan HL, Tykocki NR, DiCarlo SE, Roccabianca S. Remodeling of extracellular matrix in the urinary bladder of paraplegic rats results in increased compliance and delayed fiber recruitment 16 weeks after spinal cord injury. Acta Biomater 2022; 141:280-289. [PMID: 35032719 PMCID: PMC8898290 DOI: 10.1016/j.actbio.2022.01.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Revised: 12/17/2021] [Accepted: 01/07/2022] [Indexed: 01/21/2023]
Abstract
The ability of the urinary bladder to maintain low intravesical pressures while storing urine is key in ensuring proper organ function and highlights the key role that tissue mechanics plays in the lower urinary tract. Loss of supraspinal neuronal connections to the bladder after spinal cord injury can lead to remodeling of the structure of the bladder wall, which may alter its mechanical characteristics. In this study, we investigate if the morphology and mechanical properties of the bladder extracellular matrix are altered in rats 16 weeks after spinal cord injury as compared to animals who underwent sham surgery. We measured and quantified the changes in bladder geometry and mechanical behavior using histological analysis, tensile testing, and constitutive modeling. Our results suggest bladder compliance is increased in paraplegic animals 16 weeks post-injury. Furthermore, constitutive modeling showed that increased distensibility was driven by an increase in collagen fiber waviness, which altered the distribution of fiber recruitment during loading. STATEMENT OF SIGNIFICANCE: The ability of the urinary bladder to store urine under low pressure is key in ensuring proper organ function. This highlights the important role that mechanics plays in the lower urinary tract. Loss of control of neurologic connection to the bladder from spinal cord injury can lead to changes of the structure of the bladder wall, resulting in altered mechanical characteristics. We found that the bladder wall's microstructure in rats 16 weeks after spinal cord injury is more compliant than in healthy animals. This is significant since it is the longest time post-injury analyzed, to date. Understanding the extreme remodeling capabilities of the bladder in pathological conditions is key to inform new possible therapies.
Collapse
Affiliation(s)
- Tyler G Tuttle
- Michigan State University, Department of Mechanical Engineering, 428 S. Shaw Lane, Rm 2555, East Lansing, MI 48824, United States
| | - Heidi L Lujan
- Michigan State University, Department of Physiology, 567 Wilson Rd., Rm 2201, East Lansing, MI 48824, United States
| | - Nathan R Tykocki
- Michigan State University, Department of Pharmacology and Toxicology, 1355 Bogue St., B436 Life Science Building, East Lansing, MI 48824, United States
| | - Stephen E DiCarlo
- Michigan State University, Department of Physiology, 567 Wilson Rd., Rm 2201, East Lansing, MI 48824, United States
| | - Sara Roccabianca
- Michigan State University, Department of Mechanical Engineering, 428 S. Shaw Lane, Rm 2555, East Lansing, MI 48824, United States.
| |
Collapse
|
4
|
Tuttle T, Darios E, Watts SW, Roccabianca S. Aortic stiffness is lower when perivascular adipose tissue (PVAT) is included: a novel ex vivo mechanics study. Am J Physiol Heart Circ Physiol 2022; 322:H1003-H1013. [PMID: 35275760 DOI: 10.1152/ajpheart.00574.2021] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Perivascular adipose tissue (PVAT) is increasingly recognized as an essential layer of the functional vasculature, being responsible for producing vasoactive substances and assisting arterial stress relaxation. Here we test the hypothesis that PVAT reduces aortic stiffness. Our model was the thoracic aorta of the male Sprague Dawley rat. Uniaxial mechanical tests for three groups of tissue were performed: aorta +PVAT (+PVAT), aorta - PVAT (-PVAT), and isolated PVAT (PVAT only). The output of the mechanical test is reported in the form of a Cauchy stress-stretch curve. This work presents a novel, physiologically relevant approach to measure mechanical stiffness ex vivo in isolated PVAT. Low-stress stiffness (), high-stress stiffness (), and the stress corresponding to a stretch of 1.2 () were measured as metrics of distensibility. The low-stress stiffness was largest in the -PVAT samples and smallest in PVAT only samples. Both the high-stress stiffness and the stress at 1.2 stretch were significantly higher in -PVAT samples when compared to +PVAT samples. Taken together these results suggest that -PVAT samples are stiffer (less distensible) both at low stress (not significant) as well as at high stress (significant) when compared to +PVAT samples. These conclusions are supported by the results of the continuum mechanics material model we also used to interpret the same experimental data. Thus, tissue stiffness is significantly lower when considering PVAT as part of the aortic wall. As such, PVAT should be considered as a target for improving vascular function in diseases with elevated aortic stiffness, including hypertension.
Collapse
Affiliation(s)
- Tyler Tuttle
- Department of Mechanical Engineering, Michigan State University, East Lansing, MI, United States
| | - Emma Darios
- Department of Pharmacology and Toxicology, Michigan State University, East Lansing, MI, United States
| | - Stephanie W Watts
- Department of Pharmacology and Toxicology, Michigan State University, East Lansing, MI, United States
| | - Sara Roccabianca
- Department of Mechanical Engineering, Michigan State University, East Lansing, MI, United States
| |
Collapse
|
5
|
Rebecca M, Sripriya K, Bharathselvi M, Shantha B, Vijaya L, Angayarkanni N. Increased Desmosine in the lens capsules is associated with augmented elastin turnover in Pseudoexfoliation syndrome. Exp Eye Res 2021; 215:108898. [PMID: 34929161 DOI: 10.1016/j.exer.2021.108898] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2021] [Revised: 12/07/2021] [Accepted: 12/13/2021] [Indexed: 12/29/2022]
Abstract
Pseudoexfoliation syndrome (PXF) is an idiopathic disease with a high prevalence rate. The elastosis disorder is contributed by genetic and non-genetic factors. Elastin dysregulation associated with the disease mechanism is incompletely understood. This study evaluated the molecules of the elastogenesis machinery in PXF. Lens capsule and aqueous humor (aqH) samples (age/sex-matched) were collected from the eyes with PXF alone and PXF with glaucoma (PXF-G) undergoing Extra Capsular Cataract Extraction (ECCE) surgery. The Elastin turnover was assessed by estimating Desmosine levels in the lens capsules by HPLC analysis. Expression of elastogenesis genes [EMILIN1, CLU, FBN1, FN1, FBLN5, FBLN4 and LOXL1] were evaluated in the lens capsule by qPCR while the proteins were assessed in aqH by western blot analysis. The Desmosine content in the lens capsules were 3-fold and 6-fold elevated in PXF (P = 0.02) and PXF-G (P = 0.01) respectively compared to the cataract-alone, indicating increased elastin degradation. A significant increase in the transcript levels of the CLU, FBLN4, EMILIN1, FBLN5, FN1, FBN1, LOXL1 along with significant changes in protein expression of CLU, FBLN5, FBN1 and LOXL1 signified up-regulation of the elastogenesis machinery. The study provides direct evidence of augmented elastin degradation and turnover in the lens capsule of PXF marked by increased Desmosine content and the expression of proteins involved in mature elastin formation.
Collapse
Affiliation(s)
- Manohar Rebecca
- RS Mehta Jain Dept. of Biochemistry and Cell Biology, KBIRVO Block, Vision Research Foundation, Chennai, 600006, India; Tamil Nadu Dr. MGR Medical University, Guindy, Chennai, 600032, India
| | - Krishnamoorthy Sripriya
- Smt. Jadhavbai Nathamal Singhvee Glaucoma Services, Medical Research Foundation, Sankara Nethralaya, Chennai, 600006, India
| | - M Bharathselvi
- RS Mehta Jain Dept. of Biochemistry and Cell Biology, KBIRVO Block, Vision Research Foundation, Chennai, 600006, India
| | - B Shantha
- Smt. Jadhavbai Nathamal Singhvee Glaucoma Services, Medical Research Foundation, Sankara Nethralaya, Chennai, 600006, India
| | - Lingam Vijaya
- Smt. Jadhavbai Nathamal Singhvee Glaucoma Services, Medical Research Foundation, Sankara Nethralaya, Chennai, 600006, India
| | - Narayanasamy Angayarkanni
- RS Mehta Jain Dept. of Biochemistry and Cell Biology, KBIRVO Block, Vision Research Foundation, Chennai, 600006, India.
| |
Collapse
|
6
|
A Data-Driven Memory-Dependent Modeling Framework for Anomalous Rheology: Application to Urinary Bladder Tissue. FRACTAL AND FRACTIONAL 2021. [DOI: 10.3390/fractalfract5040223] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
We introduce a data-driven fractional modeling framework for complex materials, and particularly bio-tissues. From multi-step relaxation experiments of distinct anatomical locations of porcine urinary bladder, we identify an anomalous relaxation character, with two power-law-like behaviors for short/long long times, and nonlinearity for strains greater than 25%. The first component of our framework is an existence study, to determine admissible fractional viscoelastic models that qualitatively describe linear relaxation. After the linear viscoelastic model is selected, the second stage adds large-strain effects to the framework through a fractional quasi-linear viscoelastic approach for the nonlinear elastic response of the bio-tissue of interest. From single-step relaxation data of the urinary bladder, a fractional Maxwell model captures both short/long-term behaviors with two fractional orders, being the most suitable model for small strains at the first stage. For the second stage, multi-step relaxation data under large strains were employed to calibrate a four-parameter fractional quasi-linear viscoelastic model, that combines a Scott-Blair relaxation function and an exponential instantaneous stress response, to describe the elastin/collagen phases of bladder rheology. Our obtained results demonstrate that the employed fractional quasi-linear model, with a single fractional order in the range α = 0.25–0.30, is suitable for the porcine urinary bladder, producing errors below 2% without need for recalibration over subsequent applied strains. We conclude that fractional models are attractive tools to capture the bladder tissue behavior under small-to-large strains and multiple time scales, therefore being potential alternatives to describe multiple stages of bladder functionality.
Collapse
|
7
|
Tuttle TG, Morhardt DR, Poli AA, Park JM, Arruda EM, Roccabianca S. Investigation of Fiber-Driven Mechanical Behavior of Human and Porcine Bladder Tissue Tested Under Identical Conditions. J Biomech Eng 2021; 143:111007. [PMID: 34159357 DOI: 10.1115/1.4051525] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Indexed: 11/08/2022]
Abstract
The urinary bladder is a highly dynamic organ that undergoes large deformations several times per day. Mechanical characteristics of the tissue are crucial in determining the function and dysfunction of the organ. Yet, literature reporting on the mechanical properties of human bladder tissue is scarce and, at times, contradictory. In this study, we focused on mechanically testing tissue from both human and pig bladders using identical protocols to validate the use of pigs as a model for the human bladder. Furthermore, we tested the effect of two treatments on tissue mechanical properties. Namely, elastase to digest elastin fibers, and oxybutynin to reduce smooth muscle cell spasticity. Additionally, mechanical properties based on the anatomical direction of testing were evaluated. We implemented two different material models to aid in the interpretation of the experimental results. We found that human tissue behaves similarly to pig tissue at high deformations (collagen-dominated behavior) while we detected differences between the species at low deformations (amorphous matrix-dominated behavior). Our results also suggest that elastin could play a role in determining the behavior of the fiber network. Finally, we confirmed the anisotropy of the tissue, which reached higher stresses in the transverse direction when compared to the longitudinal direction.
Collapse
Affiliation(s)
- Tyler G Tuttle
- Mechanical Engineering Department, Michigan State University, 474 S. Shaw Lane, East Lansing, MI 48824
| | - Duncan R Morhardt
- Department of Urology, Boston Children's Hospital, 300 Longwood Avenue, Boston, MA 02115
| | - Andrea A Poli
- Mechanical Engineering Department, University of Michigan, 2350 Hayward Street, Ann Arbor, MI 48109
| | - John M Park
- Department of Urology, Michigan Medicine, 1500 E. Medical Drive, Ann Arbor, MI 48019
| | - Ellen M Arruda
- Mechanical Engineering Department, University of Michigan, 2350 Hayward Street, Ann Arbor, MI 48109
| | - Sara Roccabianca
- Mechanical Engineering Department, Michigan State University, 474 S. Shaw Lane, East Lansing, MI 48824
| |
Collapse
|
8
|
Bauer M, Morales-Orcajo E, Klemm L, Seydewitz R, Fiebach V, Siebert T, Böl M. Biomechanical and microstructural characterisation of the porcine stomach wall: Location- and layer-dependent investigations. Acta Biomater 2020; 102:83-99. [PMID: 31760221 DOI: 10.1016/j.actbio.2019.11.038] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Revised: 11/19/2019] [Accepted: 11/19/2019] [Indexed: 12/14/2022]
Abstract
The mechanical properties of the stomach wall help to explain its function of storing, mixing, and emptying in health and disease. However, much remains unknown about its mechanical properties, especially regarding regional heterogeneities and wall microstructure. Consequently, the present study aimed to assess regional differences in the mechanical properties and microstructure of the stomach wall. In general, the stomach wall and the different tissue layers exhibited a nonlinear stress-stretch relationship. Regional differences were found in the mechanical response and the microstructure. The highest stresses of the entire stomach wall in longitudinal direction were found in the corpus (201.5 kPa), where food is ground followed by the antrum (73.1 kPa) and the fundus (26.6 kPa). In contrast, the maximum stresses in circumferential direction were 39.7 kPa, 26.2 kPa, and 15.7 kPa for the antrum, fundus, and corpus, respectively. Independent of the fibre orientation and with respect to the biaxial loading direction, partially clear anisotropic responses were detected in the intact wall and the muscular layer. In contrast, the innermost mucosal layer featured isotropic mechanical characteristics. Pronounced layers of circumferential and longitudinal muscle fibres were found in the fundus only, whereas corpus and antrum contained almost exclusively circumferential orientated muscle fibres. This specific stomach structure mirrors functional differences in the fundus as well as corpus and antrum. Within this study, the load transfer mechanisms, connected with these wavy layers but also in total with the stomach wall's microstructure, are discussed. STATEMENT OF SIGNIFICANCE: This article examines for the first time the layer-specific mechanical and histological properties of the stomach wall attending to the location of the sample. Moreover, both mechanical behaviour and microstructure were explicitly match identifying the heterogeneous characteristics of the stomach. On the one hand, the results of this study contribute to the understanding of stomach mechanics and thus to their functional understanding of stomach motility. On the other hand, they are relevant to the fields of constitutive formulation of stomach tissue, whole stomach mechanics, and stomach-derived scaffolds i.e., tissue-engineering grafts.
Collapse
|
9
|
Khoiy KA, Pant AD, Amini R. Quantification of Material Constants for a Phenomenological Constitutive Model of Porcine Tricuspid Valve Leaflets for Simulation Applications. J Biomech Eng 2019; 140:2681002. [PMID: 29801174 DOI: 10.1115/1.4040126] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2017] [Indexed: 11/08/2022]
Abstract
The tricuspid valve is a one-way valve on the pulmonary side of the heart, which prevents backflow of blood during ventricular contractions. Development of computational models of the tricuspid valve is important both in understanding the normal valvular function and in the development/improvement of surgical procedures and medical devices. A key step in the development of such models is quantification of the mechanical properties of the tricuspid valve leaflets. In this study, after examining previously measured five-loading-protocol biaxial stress-strain response of porcine tricuspid valves, a phenomenological constitutive framework was chosen to represent this response. The material constants were quantified for all three leaflets, which were shown to be highly anisotropic with average anisotropy indices of less than 0.5 (an anisotropy index value of 1 indicates a perfectly isotropic response, whereas a smaller value of the anisotropy index indicates an anisotropic response). To obtain mean values of material constants, stress-strain responses of the leaflet samples were averaged and then fitted to the constitutive model (average R2 over 0.9). Since the sample thicknesses were not hugely different, averaging the data using the same tension levels and stress levels produced similar average material constants for each leaflet.
Collapse
Affiliation(s)
- Keyvan Amini Khoiy
- Department of Biomedical Engineering, The University of Akron Olson Research Center, Room 322/3 260 South Forge Street, Akron, OH 44325 e-mail:
| | - Anup D Pant
- Department of Biomedical Engineering, The University of Akron Olson Research Center, Room 322/3 260 South Forge Street, Akron, OH 44325 e-mail:
| | - Rouzbeh Amini
- Mem. ASME Department of Biomedical Engineering, The University of Akron Olson Research Center, , Akron, OH 44325 e-mail:
| |
Collapse
|
10
|
Location-dependent correlation between tissue structure and the mechanical behaviour of the urinary bladder. Acta Biomater 2018; 75:263-278. [PMID: 29772347 DOI: 10.1016/j.actbio.2018.05.014] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2018] [Revised: 05/04/2018] [Accepted: 05/09/2018] [Indexed: 01/29/2023]
Abstract
The mechanical properties of the urinary bladder wall are important to understand its filling-voiding cycle in health and disease. However, much remains unknown about its mechanical properties, especially regarding regional heterogeneities and wall microstructure. The present study aimed to assess the regional differences in the mechanical properties and microstructure of the urinary bladder wall. Ninety (n=90) samples of porcine urinary bladder wall (ten samples from nine different locations) were mechanically and histologically analysed. Half of the samples (n=45) were equibiaxially tested within physiological conditions, and the other half, matching the sample location of the mechanical tests, was frozen, cryosectioned, and stained with Picro-Sirius red to differentiate smooth muscle cells, extracellular matrix, and fat. The bladder wall shows a non-linear stress-stretch relationship with hysteresis and softening effects. Regional differences were found in the mechanical response and in the microstructure. The trigone region presents higher peak stresses and thinner muscularis layer compared to the rest of the bladder. Furthermore, the ventral side of the bladder presents anisotropic characteristics, whereas the dorsal side features perfect isotropic behaviour. This response matches the smooth muscle fibre bundle orientation within the tunica muscularis. This layer, comprising approximately 78% of the wall thickness, is composed of two fibre bundle arrangements that are cross-oriented, one with respect to the other, varying the angle between them across the organ. That is, the ventral side presents a 60°/120° cross-orientation structure, while the muscle bundles were oriented perpendicular in the dorsal side. STATEMENT OF SIGNIFICANCE In the present study, we demonstrate that the mechanical properties and the microstructure of the urinary bladder wall are heterogeneous across the organ. The mechanical properties and the microstructure of the urinary bladder wall within nine specific locations matching explicitly the mechanical and structural variations have been examined. On the one hand, the results of this study contribute to the understanding of bladder mechanics and thus to their functional understanding of bladder filling and voiding. On the other hand, they are relevant to the fields of constitutive formulation of bladder tissue, whole bladder mechanics, and bladder-derived scaffolds i.e., tissue-engineering grafts.
Collapse
|
11
|
Cheng F, Birder LA, Kullmann FA, Hornsby J, Watton PN, Watkins S, Thompson M, Robertson AM. Layer-dependent role of collagen recruitment during loading of the rat bladder wall. Biomech Model Mechanobiol 2017; 17:403-417. [PMID: 29039043 DOI: 10.1007/s10237-017-0968-5] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2017] [Accepted: 10/03/2017] [Indexed: 02/02/2023]
Abstract
In this work, we re-evaluated long-standing conjectures as to the source of the exceptionally large compliance of the bladder wall. Whereas these conjectures were based on indirect measures of loading mechanisms, in this work we take advantage of advances in bioimaging to directly assess collagen fibers and wall architecture during biaxial loading. A custom biaxial mechanical testing system compatible with multiphoton microscopy was used to directly measure the layer-dependent collagen fiber recruitment in bladder tissue from 9 male Fischer rats (4 adult and 5 aged). As for other soft tissues, the bladder loading curve was exponential in shape and could be divided into toe, transition and high stress regimes. The relationship between collagen recruitment and loading curves was evaluated in the context of the inner (lamina propria) and outer (detrusor smooth muscle) layers. The large extensibility of the bladder was found to be possible due to folds in the wall (rugae) that provide a mechanism for low resistance flattening without any discernible recruitment of collagen fibers throughout the toe regime. For more extensible bladders, as the loading extended into the transition regime, a gradual coordinated recruitment of collagen fibers between the lamina propria layer and detrusor smooth muscle layer was found. A second important finding was that wall extensibility could be lost by premature recruitment of collagen in the outer wall that cut short the toe region. This change was correlated with age. This work provides, for the first time, a mechanistic understanding of the role of collagen recruitment in determining bladder extensibility and capacitance.
Collapse
Affiliation(s)
- Fangzhou Cheng
- Department of Mechanical Engineering & Materials Science, University of Pittsburgh, Pittsburgh, PA, USA
| | - Lori A Birder
- Department of Pharmacology & Chemical Biology, University of Pittsburgh, Pittsburgh, PA, USA
- Department of Medicine, University of Pittsburgh, Pittsburgh, PA, USA
| | - F Aura Kullmann
- Department of Medicine, University of Pittsburgh, Pittsburgh, PA, USA
| | - Jack Hornsby
- Institute of Biomedical Engineering, University of Oxford, Oxford, UK
| | - Paul N Watton
- Department of Mechanical Engineering & Materials Science, University of Pittsburgh, Pittsburgh, PA, USA
- Department of Computer Science & INSIGNEO Institute for In Silico Medicine, University of Sheffield, Sheffield, UK
| | - Simon Watkins
- Center for Biologic Imaging, University of Pittsburgh, Pittsburgh, PA, USA
| | - Mark Thompson
- Institute of Biomedical Engineering, University of Oxford, Oxford, UK
| | - Anne M Robertson
- Department of Mechanical Engineering & Materials Science, University of Pittsburgh, Pittsburgh, PA, USA.
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA.
| |
Collapse
|
12
|
Vakilian S, Mashayekhan S, Shabani I, Khorashadizadeh M, Fallah A, Soleimani M. Structural stability and sustained release of protein from a multilayer nanofiber/nanoparticle composite. Int J Biol Macromol 2015; 75:248-57. [DOI: 10.1016/j.ijbiomac.2015.01.051] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2014] [Revised: 01/14/2015] [Accepted: 01/16/2015] [Indexed: 02/08/2023]
|
13
|
Mauney JR, Adam RM. Dynamic reciprocity in cell-scaffold interactions. Adv Drug Deliv Rev 2015; 82-83:77-85. [PMID: 25453262 DOI: 10.1016/j.addr.2014.10.016] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2014] [Revised: 09/07/2014] [Accepted: 10/15/2014] [Indexed: 12/14/2022]
Abstract
Tissue engineering in urology has shown considerable promise. However, there is still much to understand, particularly regarding the interactions between scaffolds and their host environment, how these interactions regulate regeneration and how they may be enhanced for optimal tissue repair. In this review, we discuss the concept of dynamic reciprocity as applied to tissue engineering, i.e. how bi-directional signaling between implanted scaffolds and host tissues such as the bladder drives the process of constructive remodeling to ensure successful graft integration and tissue repair. The impact of scaffold content and configuration, the contribution of endogenous and exogenous bioactive factors, the influence of the host immune response and the functional interaction with mechanical stimulation are all considered. In addition, the temporal relationships of host tissue ingrowth, bioactive factor mobilization, scaffold degradation and immune cell infiltration, as well as the reciprocal signaling between discrete cell types and scaffolds are discussed. Improved understanding of these aspects of tissue repair will identify opportunities for optimization of repair that could be exploited to enhance regenerative medicine strategies for urology in future studies.
Collapse
|
14
|
Ribeiro GS, Souza DBD, Cortez CM, Silva D, Costa WS, Sampaio FJB. Effects of prepubertal corticosterone treatment on urinary bladder. Acta Cir Bras 2014; 29 Suppl 3:55-9. [PMID: 25351158 DOI: 10.1590/s0102-86502014001700011] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
PURPOSE The aim of this work was to analyze the bladder wall modifications after a chronic treatment with high doses of corticosterone in prepubertal rats. METHODS This study included 26 male rats assigned into four groups: T30 was treated with corticosterone until 29 days of age and killed at day 30, while T65 group received the same treatment but was killed at day 65. Each group had its own control group (C30 and C65). For treated animals, daily intraperitoneal injections of corticosterone (20 mg/Kg) were administered between 7th and 29th day of life. Bladders were removed and collagen, smooth muscle, elastic fibers system, vascular density and epithelium were analyzed by morphometrical methods, immunofluorescence, and biochemistry. RESULTS Vascular density in lamina propria was reduced by 40% (p<0.05) in group T65. Collagen organization was altered in T30 and T65, although total collagen concentration was unchanged. The T65 group had an increase in elastic system fibers. There was no difference in epithelial height and cell density between the groups. Concerning the smooth muscle fibers density we observed a 19% increase (p<0.05) in the T65 group. CONCLUSION Prepubertal administration of corticosterone induces structural modifications in the bladder of rats in a medium term analysis.
Collapse
Affiliation(s)
| | | | - Célia M Cortez
- Dept. of Applied Mathematics, State University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil
| | - Dílson Silva
- Dept. of Applied Mathematics, State University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil
| | | | | |
Collapse
|
15
|
Towards an in vitro model mimicking the foreign body response: tailoring the surface properties of biomaterials to modulate extracellular matrix. Sci Rep 2014; 4:6325. [PMID: 25234587 PMCID: PMC4168285 DOI: 10.1038/srep06325] [Citation(s) in RCA: 64] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2014] [Accepted: 07/28/2014] [Indexed: 12/24/2022] Open
Abstract
Despite various studies to minimize host reaction following a biomaterial implantation, an appealing strategy in regenerative medicine is to actively use such an immune response to trigger and control tissue regeneration. We have developed an in vitro model to modulate the host response by tuning biomaterials' surface properties through surface modifications techniques as a new strategy for tissue regeneration applications. Results showed tunable surface topography, roughness, wettability, and chemistry by varying treatment type and exposure, allowing for the first time to correlate the effect of these surface properties on cell attachment, morphology, strength and proliferation, as well as proinflammatory (IL-1β, IL-6) and antiflammatory cytokines (TGF-β1, IL-10) secreted in medium, and protein expression of collagen and elastin. Surface microstructuring, derived from chloroform partial etching, increased surface roughness and oxygen content. This resulted in enhanced cell adhesion, strength and proliferation as well as a balance of soluble factors for optimum collagen and elastin synthesis for tissue regeneration. By linking surface parameters to cell activity, we could determine the fate of the regenerated tissue to create successful soft tissue-engineered replacement.
Collapse
|
16
|
Fan R, Sacks MS. Simulation of planar soft tissues using a structural constitutive model: Finite element implementation and validation. J Biomech 2014; 47:2043-54. [PMID: 24746842 DOI: 10.1016/j.jbiomech.2014.03.014] [Citation(s) in RCA: 79] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2013] [Revised: 03/11/2014] [Accepted: 03/11/2014] [Indexed: 10/25/2022]
Abstract
Computational implementation of physical and physiologically realistic constitutive models is critical for numerical simulation of soft biological tissues in a variety of biomedical applications. It is well established that the highly nonlinear and anisotropic mechanical behaviors of soft tissues are an emergent behavior of the underlying tissue microstructure. In the present study, we have implemented a structural constitutive model into a finite element framework specialized for membrane tissues. We noted that starting with a single element subjected to uniaxial tension, the non-fibrous tissue matrix must be present to prevent unrealistic tissue deformations. Flexural simulations were used to set the non-fibrous matrix modulus because fibers have little effects on tissue deformation under three-point bending. Multiple deformation modes were simulated, including strip biaxial, planar biaxial with two attachment methods, and membrane inflation. Detailed comparisons with experimental data were undertaken to insure faithful simulations of both the macro-level stress-strain insights into adaptations of the fiber architecture under stress, such as fiber reorientation and fiber recruitment. Results indicated a high degree of fidelity and demonstrated interesting microstructural adaptions to stress and the important role of the underlying tissue matrix. Moreover, we apparently resolve a discrepancy in our 1997 study (Billiar and Sacks, 1997. J. Biomech. 30 (7), 753-756) where we observed that under strip biaxial stretch the simulated fiber splay responses were not in good agreement with the experimental results, suggesting non-affine deformations may have occurred. However, by correctly accounting for the isotropic phase of the measured fiber splay, good agreement was obtained. While not the final word, these simulations suggest that affine fiber kinematics for planar collagenous tissues is a reasonable assumption at the macro level. Simulation tools such as these are imperative in the design and simulation of native and engineered tissues.
Collapse
Affiliation(s)
- Rong Fan
- Center for Cardiovascular Simulation, Institute for Computational Engineering and Sciences, Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, USA
| | - Michael S Sacks
- Center for Cardiovascular Simulation, Institute for Computational Engineering and Sciences, Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, USA.
| |
Collapse
|
17
|
Pok S, Dhane DV, Madihally SV. Computational simulation modelling of bioreactor configurations for regenerating human bladder. Comput Methods Biomech Biomed Engin 2013; 16:840-51. [DOI: 10.1080/10255842.2011.641177] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
18
|
Sivaraman B, Bashur CA, Ramamurthi A. Advances in biomimetic regeneration of elastic matrix structures. Drug Deliv Transl Res 2012; 2:323-50. [PMID: 23355960 PMCID: PMC3551595 DOI: 10.1007/s13346-012-0070-6] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Elastin is a vital component of the extracellular matrix, providing soft connective tissues with the property of elastic recoil following deformation and regulating the cellular response via biomechanical transduction to maintain tissue homeostasis. The limited ability of most adult cells to synthesize elastin precursors and assemble them into mature crosslinked structures has hindered the development of functional tissue-engineered constructs that exhibit the structure and biomechanics of normal native elastic tissues in the body. In diseased tissues, the chronic overexpression of proteolytic enzymes can cause significant matrix degradation, to further limit the accumulation and quality (e.g., fiber formation) of newly deposited elastic matrix. This review provides an overview of the role and importance of elastin and elastic matrix in soft tissues, the challenges to elastic matrix generation in vitro and to regenerative elastic matrix repair in vivo, current biomolecular strategies to enhance elastin deposition and matrix assembly, and the need to concurrently inhibit proteolytic matrix disruption for improving the quantity and quality of elastogenesis. The review further presents biomaterial-based options using scaffolds and nanocarriers for spatio-temporal control over the presentation and release of these biomolecules, to enable biomimetic assembly of clinically relevant native elastic matrix-like superstructures. Finally, this review provides an overview of recent advances and prospects for the application of these strategies to regenerating tissue-type specific elastic matrix structures and superstructures.
Collapse
Affiliation(s)
- Balakrishnan Sivaraman
- Department of Biomedical Engineering, The Cleveland Clinic, 9500 Euclid Avenue, ND 20, Cleveland, OH 44195, USA
| | - Chris A. Bashur
- Department of Biomedical Engineering, The Cleveland Clinic, 9500 Euclid Avenue, ND 20, Cleveland, OH 44195, USA
| | - Anand Ramamurthi
- Department of Biomedical Engineering, The Cleveland Clinic, 9500 Euclid Avenue, ND 20, Cleveland, OH 44195, USA
| |
Collapse
|
19
|
Rubod C, Brieu M, Cosson M, Rivaux G, Clay JC, de Landsheere L, Gabriel B. Biomechanical Properties of Human Pelvic Organs. Urology 2012; 79:968.e17-22. [PMID: 22245302 DOI: 10.1016/j.urology.2011.11.010] [Citation(s) in RCA: 63] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2011] [Revised: 11/10/2011] [Accepted: 11/10/2011] [Indexed: 11/19/2022]
Affiliation(s)
- Chrystèle Rubod
- Department of Gynaecology, Jeanne de Flandre Hospital-CHRU de Lille, University Nord de France, Lille, France.
| | | | | | | | | | | | | |
Collapse
|
20
|
Bashur CA, Venkataraman L, Ramamurthi A. Tissue engineering and regenerative strategies to replicate biocomplexity of vascular elastic matrix assembly. TISSUE ENGINEERING PART B-REVIEWS 2012; 18:203-17. [PMID: 22224468 DOI: 10.1089/ten.teb.2011.0521] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Cardiovascular tissues exhibit architecturally complex extracellular matrices, of which the elastic matrix forms a major component. The elastic matrix critically maintains native structural configurations of vascular tissues, determines their ability to recoil after stretch, and regulates cell signaling pathways involved in morphogenesis, injury response, and inflammation via biomechanical transduction. The ability to tissue engineer vascular replacements that incorporate elastic matrix superstructures unique to cardiac and vascular tissues is thus important to maintaining vascular homeostasis. However, the vascular elastic matrix is particularly difficult to tissue engineer due to the inherently poor ability of adult vascular cells to synthesize elastin precursors and organize them into mature structures in a manner that replicates the biocomplexity of elastic matrix assembly during development. This review discusses current tissue engineering materials (e.g., growth factors and scaffolds) and methods (e.g., dynamic stretch and contact guidance) used to promote cellular synthesis and assembly of elastic matrix superstructures, and the limitations of these approaches when applied to smooth muscle cells, the primary elastin-generating cell type in vascular tissues. The potential application of these methods for in situ regeneration of disrupted elastic matrix at sites of proteolytic vascular disease (e.g., abdominal aortic aneurysms) is also discussed. Finally, the review describes the potential utility of alternative cell types to elastic tissue engineering and regenerative matrix repair. Future progress in the field is contingent on developing a thorough understanding of developmental elastogenesis and then mimicking the spatiotemporal changes in the cellular microenvironment that occur during that phase. This will enable us to tissue engineer clinically applicable elastic vascular tissue replacements and to develop elastogenic therapies to restore homeostasis in de-elasticized vessels.
Collapse
Affiliation(s)
- Chris A Bashur
- Department of Biomedical Engineering, Cleveland Clinic, Cleveland, Ohio, USA
| | | | | |
Collapse
|
21
|
Amini R, Eckert CE, Koomalsingh K, McGarvey J, Minakawa M, Gorman JH, Gorman RC, Sacks MS. On the in vivo deformation of the mitral valve anterior leaflet: effects of annular geometry and referential configuration. Ann Biomed Eng 2012; 40:1455-67. [PMID: 22327292 DOI: 10.1007/s10439-012-0524-5] [Citation(s) in RCA: 80] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2011] [Accepted: 01/25/2012] [Indexed: 11/29/2022]
Abstract
Alteration of the native mitral valve (MV) shape has been hypothesized to have a profound effect on the local tissue stress distribution, and is potentially linked to limitations in repair durability. The present study was undertaken to elucidate the relation between MV annular shape and central mitral valve anterior leaflet (MVAL) strain history, using flat annuloplasty in an ovine model. In addition, we report for the first time the presence of residual in vivo leaflet strains. In vivo leaflet deformations were measured using sonocrystal transducers sutured to the MVAL (n = 10), with the 3D positions acquired over the full cardiac cycle. In six animals a flat ring was sutured to the annulus and the transducer positions recorded, while in the remaining four the MV was excised from the exsanguinated heart and the stress-free transducer positions obtained. In the central region of the MVAL the peak stretch values, referenced to the minimum left ventricular pressure (LVP), were 1.10 ± 0.01 and 1.31 ± 0.03 (mean ± standard error) in the circumferential and radial directions, respectively. Following flat ring annuloplasty, the central MVAL contracted 28% circumferentially and elongated 16% radially at minimum LVP, and the circumferential direction was under a negative strain state during the entire cardiac cycle. After valve excision from the exsanguinated heart, the MVAL contracted significantly (18 and 30% in the circumferential and radial directions, respectively), indicating the presence of substantial in vivo residual strains. While the physiological function of the residual strains (and their associated stresses) are at present unknown, accounting for their presence is clearly necessary for accurate computational simulations of MV function. Moreover, we demonstrated that changes in annular geometry dramatically alter valvular functional strains in vivo. As levels of homeostatic strains are related to tissue remodeling and homeostasis, our results suggest that surgically introduced alterations in MV shape could lead to the long term MV mechanobiological and microstructural alterations that could ultimately affect MV repair durability.
Collapse
Affiliation(s)
- Rouzbeh Amini
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA
| | | | | | | | | | | | | | | |
Collapse
|
22
|
Osol G, Barron C, Mandalà M. Uterine distension differentially affects remodelling and distensibility of the uterine vasculature in non-pregnant rats. Reprod Fertil Dev 2012; 24:835-42. [DOI: 10.1071/rd11208] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2011] [Accepted: 12/21/2011] [Indexed: 11/23/2022] Open
Abstract
During pregnancy the mammalian uterine circulation undergoes significant expansive remodelling necessary for normal pregnancy outcome. The underlying mechanisms are poorly defined. The goal of this study was to test the hypothesis that myometrial stretch actively stimulates uterine vascular remodelling by developing a new surgical approach to induce unilateral uterine distension in non-pregnant rats. Three weeks after surgery, which consisted of an infusion of medical-grade silicone into the uterine lumen, main and mesometrial uterine artery and vein length, diameter and distensibility were recorded. Radial artery diameter, distensibility and vascular smooth muscle mitotic rate (Ki67 staining) were also measured. Unilateral uterine distension resulted in significant increases in the length of main uterine artery and vein and mesometrial segments but had no effect on vessel diameter or distensibility. In contrast, there were significant increases in the diameter of the radial arteries associated with the distended uterus. These changes were accompanied by reduced arterial distensibility and increased vascular muscle hyperplasia. In summary, this is the first report to show that myometrial stretch is a sufficient stimulus to induce significant remodelling of uterine vessels in non-pregnant rats. Moreover, the results indicate differential regulation of these growth processes as a function of vessel size and type.
Collapse
|
23
|
Iyer P, Walker KJ, Madihally SV. Increased matrix synthesis by fibroblasts with decreased proliferation on synthetic chitosan-gelatin porous structures. Biotechnol Bioeng 2011; 109:1314-25. [PMID: 22125268 DOI: 10.1002/bit.24396] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2011] [Revised: 11/14/2011] [Accepted: 11/17/2011] [Indexed: 01/05/2023]
Abstract
Influence of mechanical characteristics and matrix architecture of substrates used in cell culture is an important issue to tissue engineering. Chitosan-based materials have been processed into porous structures, injectable gels and membranes, and are investigated to regenerate various tissues. However, the effect of these structures on cell growth and matrix production in accordance with each of the differing scaffolds has not been examined. We investigated the influence of porous structures, hydrogels, and membranes on the growth of normal human fibroblasts and their matrix production in a serum-free system. We used chitosan alone and in combination with gelatin. Injectable hydrogels were prepared using 2-glycerol phosphate. From the same solution, porous scaffolds and membranes were formed using controlled rate freezing and lyophilization, and air-drying, respectively. Fibroblast growth was evaluated on the 4th and 10th days using flow cytometry and CFDA-SE pre-staining. Cell morphology was assessed using actin and nucleus staining. Total protein content, collagen, tropoelastin, and MMP2/MMP-9 activity in the media supernatant were assessed by BCA, Sircol™, Fastin Elastin, and fluorogeneic peptide assays. Collagen accumulated in the matrix was assessed by Sircol™ assay after pepsin/acetic acid digestion and by Masson's Trichrome staining. These results showed increased viability of fibroblasts on chitosan-gelatin porous scaffold with decreased proliferation relative to tissue culture plastic (TCP) surface despite the cells showing spindle shape. The total protein, collagen, and tropoelastin contents were higher in the spent media from chitosan-gelatin porous scaffolds compared to other conditions. MMP2/MMP9 activity was comparable to TCP. An increase in collagen content was also observed in the matrix, suggesting increased matrix deposition. In summary, matrix production is influenced by the form of chitosan structures, which significantly affects the regenerative process.
Collapse
Affiliation(s)
- Pooja Iyer
- School of Chemical Engineering, Oklahoma State University, Stillwater, Oklahoma 74078, USA
| | | | | |
Collapse
|
24
|
Strain history and TGF-β1 induce urinary bladder wall smooth muscle remodeling and elastogenesis. Biomech Model Mechanobiol 2011; 11:131-45. [PMID: 21384200 DOI: 10.1007/s10237-011-0298-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2010] [Accepted: 02/18/2011] [Indexed: 12/30/2022]
Abstract
Mechanical cues that trigger pathological remodeling in smooth muscle tissues remain largely unknown and are thought to be pivotal triggers for strain-induced remodeling. Thus, an understanding of the effects mechanical stimulation is important to elucidate underlying mechanisms of disease states and in the development of methods for smooth muscle tissue regeneration. For example, the urinary bladder wall (UBW) adaptation to spinal cord injury (SCI) includes extensive hypertrophy as well as increased collagen and elastin, all of which profoundly alter its mechanical response. In addition, the pro-fibrotic growth factor TGF-β1 is upregulated in pathologies of other smooth muscle tissues and may contribute to pathological remodeling outcomes. In the present study, we utilized an ex vivo organ culture system to investigate the response of UBW tissue under various strain-based mechanical stimuli and exogenous TGF-β1 to assess extracellular matrix (ECM) synthesis, mechanical responses, and bladder smooth muscle cell (BSMC) phenotype. Results indicated that a 0.5-Hz strain frequency triangular waveform stimulation at 15% strain resulted in fibrillar elastin production, collagen turnover, and a more compliant ECM. Further, this stretch regime induced changes in cell phenotype while the addition of TGF-β1 altered this phenotype. This phenotypic shift was further confirmed by passive strip biomechanical testing, whereby the bladder groups treated with TGF-β1 were more compliant than all other groups. TGF-β1 increased soluble collagen production in the cultured bladders. Overall, the 0.5-Hz strain-induced remodeling caused increased compliance due to elastogenesis, similar to that seen in early SCI bladders. Thus, organ culture of bladder strips can be used as an experimental model to examine ECM remodeling and cellular phenotypic shift and potentially elucidate BMSCs ability to produce fibrillar elastin using mechanical stretch either alone or in combination with growth factors.
Collapse
|
25
|
Parekh A, Cigan AD, Wognum S, Heise RL, Chancellor MB, Sacks MS. Ex vivo deformations of the urinary bladder wall during whole bladder filling: contributions of extracellular matrix and smooth muscle. J Biomech 2010; 43:1708-16. [PMID: 20398903 DOI: 10.1016/j.jbiomech.2010.02.034] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2009] [Revised: 01/21/2010] [Accepted: 02/19/2010] [Indexed: 11/19/2022]
Abstract
As the complete understanding of urinary bladder function requires knowledge of organ level deformations, we conducted ex vivo studies of surface strains of whole bladders during controlled filling. The surface strains derived from displacements of surface markers applied to the posterior surface of excised rat bladders were tracked under slow filling with pressure and volume simultaneously recorded in the passive and completely inactivated states (i.e. with and without smooth muscle tone, respectively). Bladders evaluated in the passive state exhibited spontaneous contractions and larger average peak pressures (16.7 mm Hg compared to 6.4 mm Hg in the inactive state). Overall, the bladders exhibited anisotropic deformations and were stiffer in the circumferential direction, with average peak stretch values of approximately 2.3 and approximately 1.9 in the longitudinal and circumferential directions, respectively, for both states. Although bladders in the passive state were stiffer, they had similar average peak areal stretches of 4.3 in both states. However, differences early in the filling process as a result of a loss in smooth muscle tone in the inactive state resulted in longitudinal lengthening of 36%. Idealizing the bladder as a prolate spheroid, we estimated the wall stress-strain relation during filling and demonstrated that the intact bladder exhibited the classic stress-stretch relation, with a significantly protracted low stress region and peak stresses of 36 and 51 kPa in the longitudinal and circumferential directions, respectively. The present study fills a major gap in the urinary bladder biomechanics literature, wherein knowledge of the pressure-volume-wall stress-wall strain relation was explored for the first time in a functioning organ ex vivo.
Collapse
Affiliation(s)
- Aron Parekh
- Department of Bioengineering, Swanson School of Engineering, McGowan Institute, School of Medicine, 300 Technology Drive, Pittsburgh, PA 15219, USA
| | | | | | | | | | | |
Collapse
|