1
|
Engineering Perspective on Cardiovascular Simulations of Fontan Hemodynamics: Where Do We Stand with a Look Towards Clinical Application. Cardiovasc Eng Technol 2021; 12:618-630. [PMID: 34114202 DOI: 10.1007/s13239-021-00541-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2020] [Accepted: 04/30/2021] [Indexed: 01/02/2023]
Abstract
BACKGROUND Cardiovascular simulations for patients with single ventricles undergoing the Fontan procedure can assess patient-specific hemodynamics, explore surgical advances, and develop personalized strategies for surgery and patient care. These simulations have not yet been broadly accepted as a routine clinical tool owing to a number of limitations. Numerous approaches have been explored to seek innovative solutions for improving methodologies and eliminating these limitations. PURPOSE This article first reviews the current state of cardiovascular simulations of Fontan hemodynamics. Then, it will discuss the technical progress of Fontan simulations with the emphasis of its clinical impact, noting that substantial improvements have been made in the considerations of patient-specific anatomy, flow, and blood rheology. The article concludes with insights into potential future directions involving clinical validation, uncertainty quantification, and computational efficiency. The advancements in these aspects could promote the clinical usage of Fontan simulations, facilitating its integration into routine clinical practice.
Collapse
|
2
|
Fluid-Structure Interaction Simulation of an Intra-Atrial Fontan Connection. BIOLOGY 2020; 9:biology9120412. [PMID: 33255292 PMCID: PMC7760396 DOI: 10.3390/biology9120412] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/11/2020] [Revised: 11/19/2020] [Accepted: 11/20/2020] [Indexed: 12/15/2022]
Abstract
Simple Summary A fluid-structure interaction (FSI) simulation of an intra-atrial Fontan connection was performed. Power loss and pressure drop results fluctuated less during the FSI simulation than during the simulation run with rigid walls, but there were no observable differences in time-averaged pressure drop, connection power loss or hepatic flow distribution. These results suggested that employing a rigid wall is a reasonable assumption when evaluating time-averaged hemodynamic quantities of the Fontan connection under resting breath-held flow conditions. Abstract Total cavopulmonary connection (TCPC) hemodynamics has been hypothesized to be associated with long-term complications in single ventricle heart defect patients. Rigid wall assumption has been commonly used when evaluating TCPC hemodynamics using computational fluid dynamics (CFD) simulation. Previous study has evaluated impact of wall compliance on extra-cardiac TCPC hemodynamics using fluid-structure interaction (FSI) simulation. However, the impact of ignoring wall compliance on the presumably more compliant intra-atrial TCPC hemodynamics is not fully understood. To narrow this knowledge gap, this study aims to investigate impact of wall compliance on an intra-atrial TCPC hemodynamics. A patient-specific model of an intra-atrial TCPC is simulated with an FSI model. Patient-specific 3D TCPC anatomies were reconstructed from transverse cardiovascular magnetic resonance images. Patient-specific vessel flow rate from phase-contrast magnetic resonance imaging (MRI) at the Fontan pathway and the superior vena cava under resting condition were prescribed at the inlets. From the FSI simulation, the degree of wall deformation was compared with in vivo wall deformation from phase-contrast MRI data as validation of the FSI model. Then, TCPC flow structure, power loss and hepatic flow distribution (HFD) were compared between rigid wall and FSI simulation. There were differences in instantaneous pressure drop, power loss and HFD between rigid wall and FSI simulations, but no difference in the time-averaged quantities. The findings of this study support the use of a rigid wall assumption on evaluation of time-averaged intra-atrial TCPC hemodynamic metric under resting breath-held condition.
Collapse
|
3
|
McHugo VS, Nolke L, Delassus P, MaCarthy E, McMahon CJ, Morris L. The impact of compliance on Stage 2 uni-ventricular heart circulation: An experimental assessment of the Bidirectional Glenn. Med Eng Phys 2020; 84:184-192. [PMID: 32977917 DOI: 10.1016/j.medengphy.2020.07.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Revised: 03/11/2020] [Accepted: 07/13/2020] [Indexed: 11/30/2022]
Abstract
The Bidirectional Glenn (BDG) or cavopulmonary connection is typically undertaken to volume unload the single ventricle in an effort to preserve ventricular and atrioventricular valve function. The geometry of this surgical palliation has been shown to influence the fluid energy loss as well as the distribution of flow that enters through the superior vena cava. In-vitro and in-silico studies to date have been performed on rigid wall models, while this investigation looks at the impact of flexible thin walled models versus rigid walls. Rigid and compliant models of two patient-specific Glenn geometries were fabricated and tested under various flow conditions, within a biosimulator capable of replicating patient specific flow conditions. It was found that the compliant models exhibit greater levels of energy loss compared to the rigid models. Along with these findings greater levels of turbulence was found in both compliant models compared to their rigid counterparts under ultrasound examinations. This shows that vessel compliance has a significant impact on the hemodynamics within hypoplastic left heart syndrome.
Collapse
Affiliation(s)
- V S McHugo
- Department of Mechanical and Industrial Engineering (GMIT), Galway Medical Technology Centre, Ireland.
| | - L Nolke
- Department of Pediatric Cardiology Our Lady's Children's Hospital Crumlin, Dublin, Ireland; University College Dublin School of Medicine, Belfield, Dublin, Ireland
| | - P Delassus
- Department of Mechanical and Industrial Engineering (GMIT), Galway Medical Technology Centre, Ireland
| | - E MaCarthy
- Department of Mechanical and Industrial Engineering (GMIT), Galway Medical Technology Centre, Ireland
| | - C J McMahon
- Department of Pediatric Cardiology Our Lady's Children's Hospital Crumlin, Dublin, Ireland; University College Dublin School of Medicine, Belfield, Dublin, Ireland.
| | - L Morris
- Department of Mechanical and Industrial Engineering (GMIT), Galway Medical Technology Centre, Ireland.
| |
Collapse
|
4
|
McHugo S, Nolke L, Delassus P, MacCarthy E, Morris L, McMahon CJ. An in-vitro evaluation of the flow haemodynamic performance of Gore-Tex extracardiac conduits for univentricular circulation. J Cardiothorac Surg 2020; 15:235. [PMID: 32878643 PMCID: PMC7466829 DOI: 10.1186/s13019-020-01269-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Accepted: 08/24/2020] [Indexed: 02/08/2023] Open
Abstract
OBJECTIVE(S) The Fontan procedure is a common palliative intervention for sufferers of single ventricle congenital heart defects that results in an anastomosis of the venous return to the pulmonary arteries called the total cavopulmonary connection (TCPC). In patients with palliated single ventricular heart defects, the Fontan circulation passively directs systemic venous return to the pulmonary circulation in the absence of a functional sub-pulmonary ventricle. Therefore, the Fontan circulation is highly dependent on favourable flow and energetics, and minimal energy loss is of great importance. The majority of in vitro studies, to date, employ a rigid TCPC model. Recently, few studies have incorporated flexible TCPC models, without the inclusion of commercially available conduits used in these surgical scenarios. METHOD The methodology set out in this study successfully utilizes patient-specific phantoms along with the corresponding flowrate waveforms to characterise the flow haemodynamic performance of extracardiac Gore-Tex conduits. This was achieved by comparing a rigid and flexible TCPC models against a flexible model with an integrated Gore-Tex conduit. RESULTS The flexible model with the integrated Gore-Tex graft exhibited greater levels of energy losses when compared to the rigid walled model. With this, the flow fields showed greater levels of turbulence in the complaint and Gore-Tex models compared to the rigid model under ultrasound analysis. CONCLUSION This study shows that vessel compliance along with the incorporation of Gore-Tex extracardiac conduits have significant impact on the flow haemodynamics in a patient-specific surgical scenario.
Collapse
Affiliation(s)
- Shane McHugo
- Galway Medical Technology Centre, Department of Mechanical and Industrial Engineering (GMIT), Galway, Ireland
| | - Lars Nolke
- Department of Cardiothoracic Surgery, Children's Health Ireland, Crumlin, Dublin 12, Ireland
| | - Patrick Delassus
- Galway Medical Technology Centre, Department of Mechanical and Industrial Engineering (GMIT), Galway, Ireland
| | - Eugene MacCarthy
- Galway Medical Technology Centre, Department of Mechanical and Industrial Engineering (GMIT), Galway, Ireland
| | - Liam Morris
- Galway Medical Technology Centre, Department of Mechanical and Industrial Engineering (GMIT), Galway, Ireland
| | - Colin Joseph McMahon
- Department of Pediatric Cardiology Children's Health Ireland, Crumlin, Dublin 12, Ireland.
- University College Dublin School of Medicine, Belfield, Dublin 4, Ireland.
| |
Collapse
|
5
|
Trusty PM, Tree M, Maher K, Slesnick TC, Kanter KR, Yoganathan AP, Deshpande SR. An in vitro analysis of the PediMag and CentriMag for right-sided failing Fontan support. J Thorac Cardiovasc Surg 2019; 158:1413-1421. [DOI: 10.1016/j.jtcvs.2019.04.037] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Revised: 03/22/2019] [Accepted: 04/12/2019] [Indexed: 11/16/2022]
|
6
|
Trusty PM, Tree M, Vincent D, Naber JP, Maher K, Yoganathan AP, Deshpande SR. In Vitro Examination of the VentriFlo True Pulse Pump for Failing Fontan Support. Artif Organs 2018; 43:181-188. [DOI: 10.1111/aor.13301] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2018] [Revised: 05/30/2018] [Accepted: 05/30/2018] [Indexed: 12/11/2022]
Affiliation(s)
- Phillip M. Trusty
- Wallace H. Coulter Department of Biomedical Engineering Atlanta GA USA
| | - Mike Tree
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology Atlanta GA USA
| | | | | | - Kevin Maher
- Department of Pediatrics, Pediatric Cardiology Division Emory University School of Medicine Atlanta GA USA
| | | | - Shriprasad R. Deshpande
- Department of Pediatrics, Pediatric Cardiology Division Emory University School of Medicine Atlanta GA USA
| |
Collapse
|
7
|
Tree M, Wei ZA, Trusty PM, Raghav V, Fogel M, Maher K, Yoganathan A. Using a Novel In Vitro Fontan Model and Condition-Specific Real-Time MRI Data to Examine Hemodynamic Effects of Respiration and Exercise. Ann Biomed Eng 2018; 46:135-147. [PMID: 29067563 PMCID: PMC5756106 DOI: 10.1007/s10439-017-1943-0] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2017] [Accepted: 10/09/2017] [Indexed: 12/20/2022]
Abstract
Several studies exist modeling the Fontan connection to understand its hemodynamic ties to patient outcomes (Chopski in: Experimental and Computational Assessment of Mechanical Circulatory Assistance of a Patient-Specific Fontan Vessel Configuration. Dissertation, 2013; Khiabani et al. in J Biomech 45:2376-2381, 2012; Taylor and Figueroa in Annu Rev Biomed 11:109-134, 2009; Vukicevic et al. in ASAIO J 59:253-260, 2013). The most patient-accurate of these studies include flexible, patient-specific total cavopulmonary connections. This study improves Fontan hemodynamic modeling by validating Fontan model flexibility against a patient-specific bulk compliance value, and employing real-time phase contrast magnetic resonance flow data. The improved model was employed to acquire velocity field information under breath-held, free-breathing, and exercise conditions to investigate the effect of these conditions on clinically important Fontan hemodynamic metrics including power loss and viscous dissipation rate. The velocity data, obtained by stereoscopic particle image velocimetry, was visualized for qualitative three-dimensional flow field comparisons between the conditions. Key hemodynamic metrics were calculated from the velocity data and used to quantitatively compare the flow conditions. The data shows a multi-factorial and extremely patient-specific nature to Fontan hemodynamics.
Collapse
Affiliation(s)
- Michael Tree
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Zhenglun Alan Wei
- Wallace H. Coulter School of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
- Institute of Computational Science and Cardiovascular Disease, Nanjing Medical University, Nanjing, China
| | - Phillip M Trusty
- Wallace H. Coulter School of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Vrishank Raghav
- Wallace H. Coulter School of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Mark Fogel
- Children's Hospital of Philadelphia, Philadelphia, PA, USA
| | - Kevin Maher
- Children's Healthcare of Atlanta, Atlanta, GA, USA
| | - Ajit Yoganathan
- Wallace H. Coulter School of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, USA.
| |
Collapse
|
8
|
Slesnick TC. Role of Computational Modelling in Planning and Executing Interventional Procedures for Congenital Heart Disease. Can J Cardiol 2017; 33:1159-1170. [PMID: 28843327 DOI: 10.1016/j.cjca.2017.05.024] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2017] [Revised: 05/26/2017] [Accepted: 05/27/2017] [Indexed: 10/19/2022] Open
Abstract
Increasingly, computational modelling and numerical simulations are used to help plan complex surgical and interventional cardiovascular procedures in children and young adults with congenital heart disease. From its origins more than 30 years ago, surgical planning with analysis of flow hemodynamics and energy loss/efficiency has helped design and implement many modifications to existing techniques. On the basis of patient-specific medical imaging, surgical planning allows accurate model production that can then be manipulated in a virtual surgical environment, with the proposed solutions finally tested with advanced computational fluid dynamics to evaluate the results. Applications include a broad range of congenital heart disease, including patients with single-ventricle anatomy undergoing staged palliation, those with arch obstruction, with double outlet right ventricle, or with tetralogy of Fallot. In the present work, we focus on clinical applications of this exciting field. We describe the framework for these techniques, including brief descriptions of the engineering principles applied and the interaction between "benchtop" data with medical decision-making. We highlight some early insights learned from pioneers over the past few decades, including refinements in Fontan baffle geometries and configurations. Finally, we offer a glimpse into exciting advances that are presently being explored, including use of modelling for transcatheter interventions. In this era of personalized medicine, computational modelling and surgical planning allows patient-specific tailoring of interventions to optimize clinical outcomes.
Collapse
Affiliation(s)
- Timothy C Slesnick
- Emory University School of Medicine, Children's Healthcare of Atlanta, Atlanta, Georgia.
| |
Collapse
|