1
|
Kostelnik CJ, Crouse KJ, Goldsmith JD, Eberth JF. Impact of cryopreservation on elastomuscular artery mechanics. J Mech Behav Biomed Mater 2024; 154:106503. [PMID: 38522154 DOI: 10.1016/j.jmbbm.2024.106503] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 03/04/2024] [Accepted: 03/08/2024] [Indexed: 03/26/2024]
Abstract
Low temperatures slow or halt undesired biological and chemical processes, protecting cells, tissues, and organs during storage. Cryopreservation techniques, including controlled media exchange and regulated freezing conditions, aim to mitigate the physical consequences of freezing. Dimethyl sulfoxide (DMSO), for example, is a penetrating cryoprotecting agent (CPA) that minimizes ice crystal growth by replacing intracellular water, while polyvinyl alcohol (PVA) is a nonpenetrating CPA that prevents recrystallization during thawing. Since proteins and ground substance dominate the passive properties of soft biological tissues, we studied how different freezing rates, storage temperatures, storage durations, and the presence of cryoprotecting agents (5% [v/v] DMSO + 1 mg/mL PVA) impact the histomechanical properties of the internal thoracic artery (ITA), a clinically relevant blood vessel with both elastic and muscular characteristics. Remarkably, biaxial mechanical analyses failed to reveal significant differences among the ten groups tested, suggesting that mechanical properties are virtually independent of the cryopreservation technique. Scanning electron microscopy revealed minor CPA-independent delamination in rapidly frozen samples, while cryoprotected ITAs had better post-thaw viability than their unprotected counterparts using methyl thiazole-tetrazolium (MTT) metabolic assays, especially when frozen at a controlled rate. These results can be used to inform ongoing and future studies in vascular engineering, physiology, and mechanics.
Collapse
Affiliation(s)
- Colton J Kostelnik
- Department of Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, TX, USA; Biomedical Engineering Program, University of South Carolina, Columbia, SC, USA
| | - Kiersten J Crouse
- Mechanical Engineering Department, University of South Carolina, Columbia, SC, USA
| | - Jackson D Goldsmith
- Mechanical Engineering Department, University of South Carolina, Columbia, SC, USA
| | - John F Eberth
- Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA, USA.
| |
Collapse
|
2
|
Shazly T, Eberth JF, Kostelnik CJ, Uline MJ, Chitalia VC, Spinale FG, Alshareef A, Kolachalama VB. Hydrophilic Coating Microstructure Mediates Acute Drug Transfer in Drug-Coated Balloon Therapy. ACS APPLIED BIO MATERIALS 2024; 7:3041-3049. [PMID: 38661721 PMCID: PMC11366439 DOI: 10.1021/acsabm.4c00080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/26/2024]
Abstract
Drug-coated balloon (DCB) therapy is a promising endovascular treatment for obstructive arterial disease. The goal of DCB therapy is restoration of lumen patency in a stenotic vessel, whereby balloon deployment both mechanically compresses the offending lesion and locally delivers an antiproliferative drug, most commonly paclitaxel (PTX) or derivative compounds, to the arterial wall. Favorable long-term outcomes of DCB therapy thus require predictable and adequate PTX delivery, a process facilitated by coating excipients that promotes rapid drug transfer during the inflation period. While a variety of excipients have been considered in DCB design, there is a lack of understanding about the coating-specific biophysical determinants of essential device function, namely, acute drug transfer. We consider two hydrophilic excipients for PTX delivery, urea (UR) and poly(ethylene glycol) (PEG), and examine how compositional and preparational variables in the balloon surface spray-coating process impact resultant coating microstructure and in turn acute PTX transfer to the arterial wall. Specifically, we use scanning electron image analyses to quantify how coating microstructure is altered by excipient solid content and balloon-to-nozzle spray distance during the coating procedure and correlate obtained microstructural descriptors of coating aggregation to the efficiency of acute PTX transfer in a one-dimensional ex vivo model of DCB deployment. Experimental results suggest that despite the qualitatively different coating surface microstructures and apparent PTX transfer mechanisms exhibited with these excipients, the drug delivery efficiency is generally enhanced by coating aggregation on the balloon surface. We illustrate this microstructure-function relation with a finite element-based computational model of DCB deployment, which along with our experimental findings suggests a general design principle to increase drug delivery efficiency across a broad range of DCB designs.
Collapse
Affiliation(s)
- Tarek Shazly
- Department of Biomedical Engineering Program, College of Engineering and Computing, University of South Carolina, Columbia, South Carolina 29208, United States
- Department of Mechanical Engineering, College of Engineering and Computing, University of South Carolina, Columbia, South Carolina 29208, United States
- Cardiovascular Translational Research Center, University of South Carolina, Columbia, South Carolina 29208, United States
| | - John F Eberth
- Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania 19104, United States
| | - Colton J Kostelnik
- Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania 19104, United States
- Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Mark J Uline
- Department of Biomedical Engineering Program, College of Engineering and Computing, University of South Carolina, Columbia, South Carolina 29208, United States
- Cardiovascular Translational Research Center, University of South Carolina, Columbia, South Carolina 29208, United States
- Department of Chemical Engineering, College of Engineering and Computing, University of South Carolina, Columbia, South Carolina 29208, United States
| | - Vipul C Chitalia
- Department of Medicine, Boston University School of Medicine, Boston, Massachusetts 02118, United States
- VA Coston Healthcare System, Boston, Massachusetts 02115, United States
| | - Francis G Spinale
- Department of Biomedical Engineering Program, College of Engineering and Computing, University of South Carolina, Columbia, South Carolina 29208, United States
- Cardiovascular Translational Research Center, University of South Carolina, Columbia, South Carolina 29208, United States
- Department of Cell Biology and Anatomy, School of Medicine, University of South Carolina, Columbia, South Carolina 29208, United States
| | - Ahmed Alshareef
- Department of Biomedical Engineering Program, College of Engineering and Computing, University of South Carolina, Columbia, South Carolina 29208, United States
- Department of Mechanical Engineering, College of Engineering and Computing, University of South Carolina, Columbia, South Carolina 29208, United States
- Cardiovascular Translational Research Center, University of South Carolina, Columbia, South Carolina 29208, United States
| | - Vijaya B Kolachalama
- Department of Medicine, Boston University School of Medicine, Boston, Massachusetts 02118, United States
- Department of Computer Science and Faculty of Computing & Data Sciences, Boston University, Boston, Massachusetts 02115, United States
| |
Collapse
|
3
|
Lane BA, Cardoza RJ, Lessner SM, Vyavahare NR, Sutton MA, Eberth JF. Full-field strain mapping of healthy and pathological mouse aortas using stereo digital image correlation. J Mech Behav Biomed Mater 2023; 141:105745. [PMID: 36893686 PMCID: PMC10081968 DOI: 10.1016/j.jmbbm.2023.105745] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Revised: 02/01/2023] [Accepted: 02/26/2023] [Indexed: 03/05/2023]
Abstract
The murine aorta is a complex, heterogeneous structure that undergoes large and sometimes asymmetrical deformations under loading. For analytical convenience, mechanical behavior is predominantly described using global quantities that fail to capture critical local information essential to elucidating aortopathic processes. Here, in our methodological study, we used stereo digital image correlation (StereoDIC) to measure the strain profiles of speckle-patterned healthy and elastase-infused, pathological mouse aortas submerged in a temperature-controlled liquid medium. Our unique device rotates two 15-degree stereo-angle cameras that gather sequential digital images while simultaneously performing conventional biaxial pressure-diameter and force-length testing. A StereoDIC Variable Ray Origin (VRO) camera system model is employed to correct for high-magnification image refraction through hydrating physiological media. The resultant Green-Lagrange surface strain tensor was quantified at different blood vessel inflation pressures, axial extension ratios, and after aneurysm-initiating elastase exposure. Quantified results capture large, heterogeneous, inflation-related, circumferential strains that are drastically reduced in elastase-infused tissues. Shear strains, however, were very small on the tissue's surface. Spatially averaged StereoDIC-based strains were generally more detailed than those determined using conventional edge detection techniques.
Collapse
Affiliation(s)
- Brooks A Lane
- Biomedical Engineering, University of South Carolina, Columbia, SC, USA
| | - Ricardo J Cardoza
- Mechanical Engineering and Material Science, University of Pittsburgh, Pittsburgh, PA, USA
| | - Susan M Lessner
- Biomedical Engineering, University of South Carolina, Columbia, SC, USA; Cell Biology and Anatomy, University of South Carolina, Columbia, SC, USA
| | | | - Michael A Sutton
- Mechanical Engineering, University of South Carolina, Columbia, SC, USA
| | - John F Eberth
- Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA, USA.
| |
Collapse
|
4
|
Kostelnik CJ, Hohn J, Escoto-Diaz CE, Kooistra JB, Stern MM, Swinton DE, Richardson WJ, Carver W, Eberth JF. Small-diameter artery decellularization: Effects of anionic detergent concentration and treatment duration on porcine internal thoracic arteries. J Biomed Mater Res B Appl Biomater 2022; 110:885-897. [PMID: 34855280 PMCID: PMC8854343 DOI: 10.1002/jbm.b.34969] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2021] [Revised: 10/27/2021] [Accepted: 11/13/2021] [Indexed: 11/06/2022]
Abstract
Engineered replacement materials have tremendous potential for vascular applications where over 400,000 damaged and diseased blood vessels are replaced annually in the United States alone. Unlike large diameter blood vessels, which are effectively replaced by synthetic materials, prosthetic small-diameter vessels are prone to early failure, restenosis, and reintervention surgery. We investigated the differential response of varying 0%-6% sodium dodecyl sulfate and sodium deoxycholate anionic detergent concentrations after 24 and 72 h in the presence of DNase using biochemical, histological, and biaxial mechanical analyses to optimize the decellularization process for xenogeneic vascular tissue sources, specifically the porcine internal thoracic artery (ITA). Detergent concentrations greater than 1% were successful at removing cytoplasmic and cell surface proteins but not DNA content after 24 h. A progressive increase in porosity and decrease in glycosaminoglycan (GAG) content was observed with detergent concentration. Augmented porosity was likely due to the removal of both cells and GAGs and could influence recellularization strategies. The treatment duration on the other hand, significantly improved decellularization by reducing DNA content to trace amounts after 72 h. Prolonged treatment times reduced laminin content and influenced the vessel's mechanical behavior in terms of altered circumferential stress and stretch while further increasing porosity. Collectively, DNase with 1% detergent for 72 h provided an effective and efficient decellularization strategy to be employed in the preparation of porcine ITAs as bypass graft scaffolding materials with minor biomechanical and histological penalties.
Collapse
Affiliation(s)
- CJ Kostelnik
- Biomedical Engineering Program, University of South Carolina College of Eng., Columbia, SC
| | - J Hohn
- Department of Cell Biology & Anatomy, University of South Carolina School of Med., Columbia, SC
| | - CE Escoto-Diaz
- Department of Biology, Winthrop University, Rock Hill, SC
| | - JB Kooistra
- Department of Biology, Winthrop University, Rock Hill, SC
| | - MM Stern
- Department of Biology, Winthrop University, Rock Hill, SC
| | - DE Swinton
- Department of Chemistry, Claflin University, Orangeburg, SC
| | - WJ Richardson
- Department of Bioengineering, Clemson University, Clemson, SC
| | - W Carver
- Department of Cell Biology and Anatomy, University of South Carolina, School of Medicine, Columbia, SC
| | - JF Eberth
- Department of Cell Biology & Anatomy, University of South Carolina School of Med., Columbia, SC
| |
Collapse
|
5
|
Eberth J, Humphrey J. Reduced Smooth Muscle Contractile Capacity Facilitates Maladaptive Arterial Remodeling. J Biomech Eng 2021; 144:1122986. [PMID: 34729580 DOI: 10.1115/1.4052888] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Indexed: 11/08/2022]
Abstract
Albeit seldom considered explicitly, the vasoactive state of a central artery can contribute significantly to the in vivo values of flow-induced wall shear stress and pressure-induced wall stress, which in turn are strong determinants of wall growth and remodeling. In this technical brief, we test the hypothesis that diminished vasoactive capacity compromises effective mechano-adaptations of central arteries. Toward this end, we use consistent methods to re-interpret previously published data on carotid artery remodeling in a common mouse model of induced hypertension and a separate model of connective tissue disease that results in Marfan syndrome. Animals have identical backgrounds and in both cases, the data are consistent with the hypothesis considered. In particular, individual carotid arteries with strong (normal) vasoactive capacity tend to maintain wall thickness and in vivo axial stress closer to homeostatic, thus resulting in passive circumferential wall stress and energy storage closer to normal values. We conclude, therefore, that effective vasoactivity helps to control the biomechanical state in which cells and matrix turnover, thus helping to delineate mechano-adaptive from maladaptive remodeling. Future analyses of experimental data and computational models of growth and remodeling should account for this strong coupling between smooth muscle contractile capacity and central arterial remodeling.
Collapse
Affiliation(s)
- JohnF Eberth
- Department of Cell Biology and Anatomy, Biomedical Engineering Program, University of South Carolina, Columbia, SC, USA
| | - Jay Humphrey
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| |
Collapse
|
6
|
Kostelnik CJ, Crouse KJ, Carver W, Eberth JF. Longitudinal histomechanical heterogeneity of the internal thoracic artery. J Mech Behav Biomed Mater 2021; 116:104314. [PMID: 33476887 DOI: 10.1016/j.jmbbm.2021.104314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Revised: 12/10/2020] [Accepted: 01/03/2021] [Indexed: 11/16/2022]
Abstract
The internal thoracic artery (ITA) is the principal choice for coronary artery bypass grafting (CABG) due to its mechanical compatibility, histological composition, anti-thrombogenic lumen, and single anastomotic junction. Originating at the subclavian artery, traversing the thoracic cavity, and terminating at the superior epigastric and musculophrenic bifurcation, bilateral ITAs follow a protracted circuitous pathway. The physiological hemodynamics, anatomical configuration, and perivascular changes that occur throughout this length influence the tissue's microstructure and gross mechanical properties. Since histomechanics play a major role in premature graft failure we used inflation-extension testing to quantify the regional material and biaxial mechanical properties at four distinct locations along the left (L) and right (R) ITA and fit the results to a structurally-motivated constitutive model. Our comparative analysis of 44 vessel segments revealed a significant increase in the amount of collagen but not smooth muscle and a significant decrease in elastin and elastic lamellae present with distance from the heart. A subsequent decrease in the total deformation energy and isotropic contribution to the strain energy was present in the LITA but not RITA. Circumferential stress and compliance generally decreased along the length of the LITA while axial stress increased in the RITA. When comparing RITAs to LITAs, some morphological and histological differences were found in proximal sections while distal sections revealed differences predominantly in compliance and axial stress. Overall, this information can be used to better guide graft selection, graft preparation, and xenograft-based tissue-engineering strategies for CABG.
Collapse
Affiliation(s)
- Colton J Kostelnik
- Biomedical Engineering Program, University of South Carolina, Columbia, SC, USA
| | - Kiersten J Crouse
- Mechanical Engineering Department, University of South Carolina, Columbia, SC, USA
| | - Wayne Carver
- Cell Biology and Anatomy Department, University of South Carolina, Columbia, SC, USA
| | - John F Eberth
- Biomedical Engineering Program, University of South Carolina, Columbia, SC, USA; Cell Biology and Anatomy Department, University of South Carolina, Columbia, SC, USA.
| |
Collapse
|
7
|
Watson SR, Cooper KM, Liu P, Gharraee N, Du L, Han SM, Peña EA, Sutton MA, Eberth JF, Lessner SM. Diet alters age-related remodeling of aortic collagen in mice susceptible to atherosclerosis. Am J Physiol Heart Circ Physiol 2021; 320:H52-H65. [PMID: 33373275 PMCID: PMC7847077 DOI: 10.1152/ajpheart.00420.2020] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 10/14/2020] [Accepted: 10/14/2020] [Indexed: 02/06/2023]
Abstract
Vascular cells restructure extracellular matrix in response to aging or changes in mechanical loading. Here, we characterized collagen architecture during age-related aortic remodeling in atherosclerosis-prone mice. We hypothesized that changes in collagen fiber orientation reflect an altered balance between passive and active forces acting on the arterial wall. We examined two factors that can alter this balance, endothelial dysfunction and reduced smooth muscle cell (SMC) contractility. Collagen fiber organization was visualized by second-harmonic generation microscopy in aortic adventitia of apolipoprotein E (apoE) knockout (KO) mice at 6 wk and 6 mo of age on a chow diet and at 7.5 mo of age on a Western diet (WD), using image analysis to yield mean fiber orientation. Adventitial collagen fibers became significantly more longitudinally oriented with aging in apoE knockout mice on chow diet. Conversely, fibers became more circumferentially oriented with aging in mice on WD. Total collagen content increased significantly with age in mice fed WD. We compared expression of endothelial nitric oxide synthase and acetylcholine-mediated nitric oxide release but found no evidence of endothelial dysfunction in older mice. Time-averaged volumetric blood flow in all groups showed no significant changes. Wire myography of aortic rings revealed decreases in active stress generation with age that were significantly exacerbated in WD mice. We conclude that the aorta displays a distinct remodeling response to atherogenic stimuli, indicated by altered collagen organization. Collagen reorganization can occur in the absence of altered hemodynamics and may represent an adaptive response to reduced active stress generation by vascular SMCs.NEW & NOTEWORTHY The following major observations were made in this study: 1) aortic adventitial collagen fibers become more longitudinally oriented with aging in apolipoprotein E knockout mice fed a chow diet; 2) conversely, adventitial collagen fibers become more circumferentially oriented with aging in apoE knockout mice fed a high-fat diet; 3) adventitial collagen content increases significantly with age in mice on a high-fat diet; 4) these alterations in collagen organization occur largely in the absence of hemodynamic changes; and 5) circumferential reorientation of collagen is associated with decreased active force generation (contractility) in aged mice on a high-fat diet.
Collapse
MESH Headings
- Age Factors
- Animals
- Aorta, Abdominal/metabolism
- Aorta, Abdominal/pathology
- Aorta, Abdominal/physiopathology
- Aorta, Thoracic/metabolism
- Aorta, Thoracic/pathology
- Aorta, Thoracic/physiopathology
- Aortic Diseases/genetics
- Aortic Diseases/metabolism
- Aortic Diseases/pathology
- Aortic Diseases/physiopathology
- Atherosclerosis/genetics
- Atherosclerosis/metabolism
- Atherosclerosis/pathology
- Atherosclerosis/physiopathology
- Diet, Western
- Disease Models, Animal
- Female
- Fibrillar Collagens/metabolism
- Male
- Mice, Knockout, ApoE
- Vascular Remodeling
- Vasoconstriction
- Mice
Collapse
Affiliation(s)
- Shana R Watson
- Department of Cell Biology and Anatomy, University of South Carolina School of Medicine, Columbia, South Carolina
| | - Kara M Cooper
- Department of Cell Biology and Anatomy, University of South Carolina School of Medicine, Columbia, South Carolina
| | - Piaomu Liu
- Department of Mathematical Sciences, Bentley University, Waltham, Massachusetts
| | - Nazli Gharraee
- Department of Cell Biology and Anatomy, University of South Carolina School of Medicine, Columbia, South Carolina
| | - Liya Du
- Department of Cell Biology and Anatomy, University of South Carolina School of Medicine, Columbia, South Carolina
| | - Savannah M Han
- Department of Cell Biology and Anatomy, University of South Carolina School of Medicine, Columbia, South Carolina
| | - Edsel A Peña
- Department of Statistics, University of South Carolina, Columbia, South Carolina
| | - Michael A Sutton
- Department of Mechanical Engineering, University of South Carolina, Columbia, South Carolina
| | - John F Eberth
- Department of Cell Biology and Anatomy, University of South Carolina School of Medicine, Columbia, South Carolina
| | - Susan M Lessner
- Department of Cell Biology and Anatomy, University of South Carolina School of Medicine, Columbia, South Carolina
| |
Collapse
|
8
|
Lane BA, Uline MJ, Wang X, Shazly T, Vyavahare NR, Eberth JF. The Association Between Curvature and Rupture in a Murine Model of Abdominal Aortic Aneurysm and Dissection. EXPERIMENTAL MECHANICS 2021; 61:203-216. [PMID: 33776072 PMCID: PMC7988338 DOI: 10.1007/s11340-020-00661-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2020] [Accepted: 08/18/2020] [Indexed: 06/12/2023]
Abstract
BACKGROUND Mouse models of abdominal aortic aneurysm (AAA) and dissection have proven to be invaluable in the advancement of diagnostics and therapeutics by providing a platform to decipher response variables that are elusive in human populations. One such model involves systemic Angiotensin II (Ang-II) infusion into low density-lipoprotein receptor-deficient (LDLr-/-) mice leading to intramural thrombus formation, inflammation, matrix degradation, dilation, and dissection. Despite its effectiveness, considerable experimental variability has been observed in AAAs taken from our Ang-II infused LDLr-/- mice (n=12) with obvious dissection occurring in 3 samples, outer bulge radii ranging from 0.73 to 2.12 mm, burst pressures ranging from 155 to 540 mmHg, and rupture location occurring 0.05 to 2.53 mm from the peak bulge location. OBJECTIVE We hypothesized that surface curvature, a fundamental measure of shape, could serve as a useful predictor of AAA failure at supra-physiological inflation pressures. METHODS To test this hypothesis, we fit well-known biquadratic surface patches to 360° micro-mechanical test data and used Spearman's rank correlation (rho) to identify relationships between failure metrics and curvature indices. RESULTS We found the strongest associations between burst pressure and the maximum value of the first principal curvature (rho=-0.591, p-val=0.061), the maximum value of Mean curvature (rho=-0.545, p-val=0.087), and local values of Mean curvature at the burst location (rho=-0.864, p-val=0.001) with only the latter significant after Bonferroni correction. Additionally, the surface profile at failure was predominantly convex and hyperbolic (saddle-shaped) as indicated by a negative sign in the Gaussian curvature. Findings reiterate the importance of shape in experimental models of AAA.
Collapse
Affiliation(s)
- B A Lane
- Biomedical Engineering Program, University of South Carolina, Columbia, SC, USA
| | - M J Uline
- Biomedical Engineering Program, University of South Carolina, Columbia, SC, USA
- Chemical Engineering Department, University of South Carolina, Columbia, SC, USA
| | - X Wang
- Biomedical Engineering Department, Clemson University, Clemson, SC, USA
| | - T Shazly
- Biomedical Engineering Program, University of South Carolina, Columbia, SC, USA
- Mechanical Engineering Department, University of South Carolina, Columbia, SC, USA
| | - N R Vyavahare
- Biomedical Engineering Department, Clemson University, Clemson, SC, USA
| | - J F Eberth
- Biomedical Engineering Program, University of South Carolina, Columbia, SC, USA
- Cell Biology and Anatomy Department, University of South Carolina, Columbia, SC, USA
| |
Collapse
|
9
|
Prim DA, Lane BA, Ferruzzi J, Shazly T, Eberth JF. Evaluation of the Stress-Growth Hypothesis in Saphenous Vein Perfusion Culture. Ann Biomed Eng 2020; 49:487-501. [PMID: 32728831 DOI: 10.1007/s10439-020-02582-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Accepted: 07/22/2020] [Indexed: 01/02/2023]
Abstract
The great saphenous vein (GSV) has served as a coronary artery bypass graft (CABG) conduit for over 50 years. Despite prevalent use, first-year failure rates remain high compared to arterial autograft options. Amongst other factors, vein graft failure can be attributed to material and mechanical mismatching that lead to apoptosis, inflammation, and intimal-medial hyperplasia. Through the implementation of the continuum mechanical-based theory of "stress-mediated growth and remodeling," we hypothesize that the mechanical properties of porcine GSV grafts can be favorably tuned for CABG applications prior to implantation using a prolonged but gradual transition from venous to arterial loading conditions in an inflammatory and thrombogenic deficient environment. To test this hypothesis, we used a hemodynamic-mimetic perfusion bioreactor to guide remodeling through stepwise incremental changes in pressure and flow over the course of 21-day cultures. Biaxial mechanical testing of vessels pre- and post-remodeling was performed, with results fit to structurally-motivated constitutive models using non-parametric bootstrapping. The theory of "small-on-large" was used to describe appropriate stiffness moduli, while histology and viability assays confirmed microstructural adaptations and vessel viability. Results suggest that stepwise transition from venous-to-arterial conditions results in a partial restoration of circumferential stretch and circumferential, but not axial, stress through vessel dilation and wall thickening in a primarily outward remodeling process. These remodeled tissues also exhibited decreased mechanical isotropy and circumferential, but not axial, stiffening. In contrast, only increases in axial stiffness were observed using culture under venous perfusion conditions and those tissues experienced moderate intimal resorption.
Collapse
Affiliation(s)
- David A Prim
- Biomedical Engineering Program, University of South Carolina, Columbia, SC, USA
| | - Brooks A Lane
- Biomedical Engineering Program, University of South Carolina, Columbia, SC, USA
| | - Jacopo Ferruzzi
- Biomedical Engineering Department, Boston University, Boston, MA, USA
| | - Tarek Shazly
- Biomedical Engineering Program, University of South Carolina, Columbia, SC, USA.,Mechanical Engineering Department, University of South Carolina, Columbia, SC, USA
| | - John F Eberth
- Biomedical Engineering Program, University of South Carolina, Columbia, SC, USA. .,Cell Biology and Anatomy Department (CBA), SOM, University of South Carolina (USC), Bldg.1, Rm. C-36, Columbia, SC, 29208, USA.
| |
Collapse
|
10
|
Abstract
Vascular tortuosity may impede blood flow, occlude the lumen, and ultimately lead to ischemia or even infarction. Mechanical loads like blood pressure, axial force, and also torsion are key factors participating in this complex mechanobiological process. The available studies on arterial torsion instability followed computational or experimental approaches, yet single available theoretical study had modeled the artery as isotropic linear elastic. This paper aim is to validate a theoretical model of arterial torsion instability against experimental data. The artery is modeled as a single-layered, nonlinear, hyperelastic, anisotropic solid, with parameters calibrated from experiment. Linear bifurcation analysis is then performed to predict experimentally measured stability margins. Uncertainties in geometrical parameters and in measured mechanical response were considered. Also, the type of rate (incremental) boundary conditions (RBCs) impact on the results was examined (e.g., dead load, fluid pressure). The predicted critical torque and twist angle followed the experimentally measured trends. The closest prediction errors in the critical torque and twist rate were 22% and 67%, respectively. Using the different RBCs incurred differences of up to 50% difference within the model predictions. The present results suggest that the model may require further improvements. However, it offers an approach that can be used to predict allowable twist levels in surgical procedures (like anastomosis and grafting) and in the design of stents for arteries subjected to high torsion levels (like the femoropopliteal arteries). It may also be instructive in understanding biomechanical processes like arterial tortuosity, kinking, and coiling.
Collapse
Affiliation(s)
- Nir Emuna
- Faculty of Aerospace Engineering, Technion-Israel Institute of Technology, Haifa 32000, Israel
| | - David Durban
- Faculty of Aerospace Engineering, Technion-Israel Institute of Technology, Haifa 32000, Israel
| |
Collapse
|
11
|
Lane BA, Lessner SM, Vyavahare NR, Sutton MA, Eberth JF. Null strain analysis of submerged aneurysm analogues using a novel 3D stereomicroscopy device. Comput Methods Biomech Biomed Engin 2020; 23:332-344. [PMID: 32068431 PMCID: PMC7289678 DOI: 10.1080/10255842.2020.1724974] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2019] [Revised: 12/13/2019] [Accepted: 01/29/2020] [Indexed: 01/05/2023]
Abstract
To measure the inhomogeneous 3D-strain fields present during inflation-extension testing of physiologically submerged micro-aneurysms, a Stereo Digital Image Correlation (StereoDIC) microscopy system is developed that revolves 15° stereo-angle cameras around a centrally-mounted target. Calibration is performed using submerged dot patterns and system accuracy verified using strain and deformation analyses for rigid body motions of speckle-patterned, micro-aneurysmal surrogates. In terms of the Green-Lagrange strain tensor and the 3D displacement fields, the results are stable even after 120 minutes, with maxima in both strain bias and strain standard deviation less than 2E-03 for all components, and micron-level displacement standard deviation.
Collapse
Affiliation(s)
- Brooks A. Lane
- Biomedical Engineering, University of South Carolina, Columbia, USA
| | - Susan M. Lessner
- Biomedical Engineering, University of South Carolina, Columbia, USA
- Cell Biology and Anatomy, University of South Carolina, Columbia, USA
| | | | | | - John F. Eberth
- Biomedical Engineering, University of South Carolina, Columbia, USA
- Cell Biology and Anatomy, University of South Carolina, Columbia, USA
| |
Collapse
|
12
|
Clark GL, Pokutta-Paskaleva AP, Lawrence DJ, Lindsey SH, Desrosiers L, Knoepp LR, Bayer CL, Gleason RL, Miller KS. Smooth muscle regional contribution to vaginal wall function. Interface Focus 2019; 9:20190025. [PMID: 31263538 PMCID: PMC6597518 DOI: 10.1098/rsfs.2019.0025] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/02/2019] [Indexed: 12/16/2022] Open
Abstract
Pelvic organ prolapse is characterized as the descent of the pelvic organs into the vaginal canal. In the USA, there is a 12% lifetime risk for requiring surgical intervention. Although vaginal childbirth is a well-established risk factor for prolapse, the underlying mechanisms are not fully understood. Decreased smooth muscle organization, composition and maximum muscle tone are characteristics of prolapsed vaginal tissue. Maximum muscle tone of the vaginal wall was previously investigated in the circumferential or axial direction under uniaxial loading; however, the vaginal wall is subjected to multiaxial loads. Further, the contribution of vaginal smooth muscle basal (resting) tone to mechanical function remains undetermined. The objectives of this study were to determine the contribution of smooth muscle basal and maximum tone to the regional biaxial mechanical behaviour of the murine vagina. Vaginal tissue from C57BL/6 mice was subjected to extension-inflation protocols (n = 10) with and without basal smooth muscle tone. Maximum tone was induced with KCl under various circumferential (n = 5) and axial (n = 5) loading conditions. The microstructure was visualized with multiphoton microscopy (n = 1), multiaxial histology (n = 4) and multiaxial immunohistochemistry (n = 4). Smooth muscle basal tone decreased material stiffness and increased anisotropy. In addition, maximum vaginal tone was decreased with increasing intraluminal pressures. This study demonstrated that vaginal muscle tone contributed to the biaxial mechanical response of murine vaginal tissue. This may be important in further elucidating the underlying mechanisms of prolapse, in order to improve current preventative and treatment strategies.
Collapse
Affiliation(s)
- Gabrielle L. Clark
- Department of Biomedical Engineering, Tulane University, 6823 St Charles Avenue, New Orleans, LA 70118, USA
| | - Anastassia P. Pokutta-Paskaleva
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, 801 Ferst Drive NW, Atlanta, GA 30332, USA
| | - Dylan J. Lawrence
- Department of Biomedical Engineering, Tulane University, 6823 St Charles Avenue, New Orleans, LA 70118, USA
| | - Sarah H. Lindsey
- Department of Pharmacology, Tulane University School of Medicine, 1430 Tulane Avenue, New Orleans, LA 70112, USA
| | - Laurephile Desrosiers
- Department of Female Pelvic Medicine and Reconstructive Surgery, University of Queensland Ochsner Clinical School, 1514 Jefferson Highway, New Orleans, LA 70121, USA
| | - Leise R. Knoepp
- Department of Female Pelvic Medicine and Reconstructive Surgery, University of Queensland Ochsner Clinical School, 1514 Jefferson Highway, New Orleans, LA 70121, USA
| | - Carolyn L. Bayer
- Department of Biomedical Engineering, Tulane University, 6823 St Charles Avenue, New Orleans, LA 70118, USA
| | - Rudolph L. Gleason
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, 801 Ferst Drive NW, Atlanta, GA 30332, USA
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Kristin S. Miller
- Department of Biomedical Engineering, Tulane University, 6823 St Charles Avenue, New Orleans, LA 70118, USA
| |
Collapse
|
13
|
Prim DA, Mohamed MA, Lane BA, Poblete K, Wierzbicki MA, Lessner SM, Shazly T, Eberth JF. Comparative mechanics of diverse mammalian carotid arteries. PLoS One 2018; 13:e0202123. [PMID: 30096185 PMCID: PMC6086448 DOI: 10.1371/journal.pone.0202123] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2017] [Accepted: 07/27/2018] [Indexed: 01/07/2023] Open
Abstract
The prevalence of diverse animal models as surrogates for human vascular pathologies necessitate a comprehensive understanding of the differences that exist between species. Comparative passive mechanics are presented here for the common carotid arteries taken from bovine, porcine, ovine, leporine, murine-rat, and murine-mouse specimens. Data is generated using a scalable biaxial mechanical testing device following consistent circumferential (pressure-diameter) and axial (force-length) testing protocols. The structural mechanical response of carotids under equivalent loading, quantified by the deformed inner radius, deformed wall thickness, lumen area compliance and axial force, varies significantly among species but generally follows allometric scaling. Conversely, descriptors of the local mechanical response within the deformed arterial wall, including mean circumferential stress, mid-wall circumferential stretch, and mean axial stress, are relatively consistent across species. Unlike the larger animals studied, the diameter distensibility curves of murine specimens are non-monotonic and have a significantly higher value at 100 mmHg. Taken together, our results provide baseline structural and mechanical information for carotid arteries across a broad range of common animal models.
Collapse
Affiliation(s)
- David A. Prim
- College of Engineering and Computing, Biomedical Engineering Program, University of South Carolina, Columbia, SC, United States of America
| | - Mohamed A. Mohamed
- Cullen College of Engineering, Biomedical Engineering Department, University of Houston, Houston, TX, United States of America
| | - Brooks A. Lane
- College of Engineering and Computing, Biomedical Engineering Program, University of South Carolina, Columbia, SC, United States of America
| | - Kelley Poblete
- College of Health Sciences, Physical Therapy Program, Texas Women’s University, Houston, TX, United States of America
| | - Mark A. Wierzbicki
- Dwight Look College of Engineering, Biomedical Engineering Department, Texas A&M University, College Station, TX, United States of America
| | - Susan M. Lessner
- College of Engineering and Computing, Biomedical Engineering Program, University of South Carolina, Columbia, SC, United States of America
- School of Medicine, Department of Cell Biology and Anatomy, University of South Carolina, Columbia, SC, United States of America
| | - Tarek Shazly
- College of Engineering and Computing, Biomedical Engineering Program, University of South Carolina, Columbia, SC, United States of America
- College of Engineering and Computing, Mechanical Engineering Department, University of South Carolina, Columbia, SC, United States of America
| | - John F. Eberth
- College of Engineering and Computing, Biomedical Engineering Program, University of South Carolina, Columbia, SC, United States of America
- School of Medicine, Department of Cell Biology and Anatomy, University of South Carolina, Columbia, SC, United States of America
- * E-mail:
| |
Collapse
|
14
|
Zhang X, Zhou B, Miranda AF, Trost LW. A Novel Noninvasive Ultrasound Vibro-elastography Technique for Assessing Patients With Erectile Dysfunction and Peyronie Disease. Urology 2018; 116:99-105. [PMID: 29548864 DOI: 10.1016/j.urology.2018.01.040] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2017] [Revised: 01/15/2018] [Accepted: 01/31/2018] [Indexed: 01/01/2023]
Abstract
OBJECTIVE To translate a novel ultrasound vibro-elastography (UVE) technique for noninvasively measuring viscoelasticity of the penis. METHODS A pilot study of UVE was performed in men with erectile dysfunction or Peyronie disease. Assessments were performed in triplicate on the lateral aspect of the penis (bilaterally) at 100, 150, and 200 Hz before and after erectogenic injection administration. Viscoelasticity of the corpora was also calculated and compared before and after injection and against measures of erectile function, including the International Index of Erectile Function-Erectile Function Domain, and the total erectogenic medication volume required for achieving a firm erection. RESULTS Significant increases in viscoelasticity were found after erectogenic injection, validating the ability of UVE to measure dynamic changes with erections. Baseline measures also significantly correlated with the volume of erectogenic medication required to achieve an erection (100 Hz, parameter estimate [PE] 2.21, P <.001; 150 Hz, PE 0.53, P = .03; 200 Hz, PE 0.34, P = .07) but not with age and International Index of Erectile Function-Erectile Function Domain. As erectogenic medications likely represent the most accurate measure of erectile function, these findings suggest a potential role for UVE as a viable diagnostic modality for erectile dysfunction. CONCLUSION This first report of the use of elastography with erectile function in humans demonstrates significant associations with responsiveness to erectogenic injection medications. These data have significant potential implications for broader clinical practice and merit further study and validation.
Collapse
Affiliation(s)
| | - Boran Zhou
- Department of Radiology, Mayo Clinic, Rochester, MN
| | | | | |
Collapse
|