1
|
Kennedy SM, A V, K A. Exploring the frontiers of metal additive manufacturing in orthopaedic implant development. MethodsX 2024; 13:103056. [PMID: 39807428 PMCID: PMC11725976 DOI: 10.1016/j.mex.2024.103056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2024] [Accepted: 11/13/2024] [Indexed: 01/16/2025] Open
Abstract
This paper provides a thorough analysis of recent advancements and emerging trends in the integration of metal additive manufacturing (AM) within orthopedic implant development. With an emphasis on the use of various metals and alloys, including titanium, cobalt-chromium, and nickel-titanium, the review looks at their characteristics and how they relate to the creation of various orthopedic implants, such as spinal implants, hip and knee replacements, and cranial-facial reconstructions. The study highlights how metal additive manufacturing (AM) can revolutionize the field by enabling customized implant designs that take patient anatomical variances into account. The review discusses the drawbacks of conventional manufacturing techniques and emphasizes the benefits of metal additive manufacturing (AM), such as increased design flexibility and decreased material waste. Important material selection factors, including mechanical qualities and biocompatibility, are covered in relation to metal additive manufacturing applications. The work ends with a summary of the issues facing metal AM today, such as surface finish and material certification, and suggestions for future developments, like the creation of advanced materials and the application of AI to design optimization.
Collapse
Affiliation(s)
- Senthil Maharaj Kennedy
- Department of Mechanical Engineering, AAA College of Engineering and Technology, Sivakasi 626005, Tamil Nadu, India
| | - Vasanthanathan A
- Department of Mechanical Engineering, Mepco Schlenk Engineering College, Sivakasi 626005, Tamil Nadu, India
| | - Amudhan K
- Department of Mechanical Engineering, Mepco Schlenk Engineering College, Sivakasi 626005, Tamil Nadu, India
| |
Collapse
|
2
|
Sun YS, Huang HH, Tsai YH, Kuo YL, Lee JW, Lee YJ, Linn TY, Chen P. Creating an extracellular matrix-like three-dimension structure to enhance the corrosion resistance and biological responses of titanium implants. J Dent Sci 2024; 19:S70-S80. [PMID: 39807433 PMCID: PMC11725070 DOI: 10.1016/j.jds.2024.09.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2024] [Revised: 09/15/2024] [Indexed: 01/16/2025] Open
Abstract
Background/purpose Titanium (Ti) is extensively used in dental and orthopedic implants due to its excellent mechanical properties. However, its smooth and biologically inert surface does not support the ingrowth of new bone, and Ti ions may have adverse biological effects. The purpose is to improve the corrosion resistance of titanium and create a 3D structured coating to enhance osseointegration through a very simple and fast surface treatment. Materials and methods This study investigated the use of sandblasting, acid etching, and NaOH leaching to produce porous Ti implants with enhanced biological activity and corrosion resistance. Results These surface modifications generated a mixed oxide layer resembling the extracellular matrix (ECM), consisting of a dense amorphous TiO2 inner layer (50-100 nm thick) and a TiO2 outer layer with interconnected pores (pore size 50-500 nm; 150-200 nm thick). The inner layer significantly improved corrosion resistance, while the hydrophilic outer layer, with its porous structure, facilitated protein albumin adsorption and promoted the attachment, proliferation, and mineralization of human bone marrow mesenchymal stem cells. Conclusion The combined surface treatment approach of sandblasting, acid etching, and NaOH leaching offers a comprehensive solution to the challenges associated with titanium implants' biological inertness and corrosion susceptibility. By enhancing both the biological activity and corrosion resistance of Ti surfaces, this protocol holds significant promise for improving dental and orthopedic implants' success rates and longevity. Future studies should focus on in vivo assessments and long-term clinical trials to further validate these findings and explore the potential for widespread clinical adoption.
Collapse
Affiliation(s)
- Ying-Sui Sun
- School of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
| | - Her-Hsiung Huang
- Department of Dentistry, National Yang Ming Chiao Tung University, Taipei, Taiwan
- Department of Bioinformatics and Medical Engineering, Asia University, Taichung, Taiwan
- Department of Medical Research, China Medical University Hospital, China Medical University, Taichung, Taiwan
- School of Dentistry, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Yi-Hsuan Tsai
- Institute of Oral Biology, School of Dentistry Graduate, National Taiwan University, Taipei, Taiwan
| | - Yu-Lin Kuo
- Department of Mechanical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan
| | - Jyh-Wei Lee
- Department of Materials Engineering, Ming Chi University of Technology, New Taipei, Taiwan
| | - Yun-Jung Lee
- School of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
| | - Thu Ya Linn
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
| | - Peng Chen
- Liaison Center for Innovative Dentistry, Graduate School of Dentistry, Tohoku University, Sendai, Japan
| |
Collapse
|
3
|
Deng T, Gong S, Cheng Y, Wang J, Zhang H, Li K, Nie Y, Shen B. Stochastic lattice-based porous implant design for improving the stress transfer in unicompartmental knee arthroplasty. J Orthop Surg Res 2024; 19:499. [PMID: 39175032 PMCID: PMC11340161 DOI: 10.1186/s13018-024-05006-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2024] [Accepted: 08/16/2024] [Indexed: 08/24/2024] Open
Abstract
BACKGROUND Unicompartmental knee arthroplasty (UKA) has been proved to be a successful treatment for osteoarthritis patients. However, the stress shielding caused by mismatch in mechanical properties between human bones and artificial implants remains as a challenging issue. This study aimed to properly design a bionic porous tibial implant and evaluate its biomechanical effect in reconstructing stress transfer pathway after UKA surgery. METHODS Voronoi structures with different strut sizes and porosities were designed and manufactured with Ti6Al4V through additive manufacturing and subjected to quasi-static compression tests. The Gibson-Ashby model was used to relate mechanical properties with design parameters. Subsequently, finite element models were developed for porous UKA, conventional UKA, and native knee to evaluate the biomechanical effect of tibial implant with designed structures during the stance phase. RESULTS The internal stress distribution on the tibia plateau in the medial compartment of the porous UKA knee was found to closely resemble that of the native knee. Furthermore, the mean stress values in the medial regions of the tibial plateau of the porous UKA knee were at least 44.7% higher than that of the conventional UKA knee for all subjects during the most loading conditions. The strain shielding reduction effect of the porous UKA knee model was significant under the implant and near the load contact sites. For subject 1 to 3, the average percentages of nodes in bone preserving and building region (strain values range from 400 to 3000 μm/m) of the porous UKA knee model, ranging from 68.7 to 80.5%, were higher than that of the conventional UKA knee model, ranging from 61.6 to 68.6%. CONCLUSIONS The comparison results indicated that the tibial implant with designed Voronoi structure offered better biomechanical functionality on the tibial plateau after UKA. Additionally, the model and associated analysis provide a well-defined design process and dependable selection criteria for design parameters of UKA implants with Voronoi structures.
Collapse
Grants
- 2020YFB1711500 the National Key Research and Development Program of China
- ZYYC21004 the 1•3•5 project for disciplines of excellence, West China Hospital, Sichuan University
- ZYGX2022YGRH007 Medico-Engineering Cooperation Funds from University of Electronic Science and Technology by the Fundamental Research Funds for the Central Universities
- 2023YFB4606700 National Key Research and Development Program
- ZYAI24038 1•3•5 project for disciplines of excellence, West China Hospital, Sichuan University
- 2022SCUH0015 0-1 Innovation Project of Sichuan University
- 2023HXFH024 1·3·5 project for disciplines of excellence-Clinical Research Fund, West China Hospital, Sichuan University
- the Interdisciplinary Crossing and Integration of Medicine and Engineering for Talent Training Fund, West China Hospital, Sichuan University
- 1·3·5 project for disciplines of excellence–Clinical Research Fund, West China Hospital, Sichuan University
Collapse
Affiliation(s)
- Tao Deng
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, 610041, China
- School of Mechanical Engineering, Sichuan University, Chengdu, 610065, China
| | - Shan Gong
- Sichuan University-Pittsburgh Institute, Sichuan University, Chengdu, 610207, China
| | - Yiwei Cheng
- Sichuan University-Pittsburgh Institute, Sichuan University, Chengdu, 610207, China
| | - Junqing Wang
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, 610041, China
| | - Hui Zhang
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, 610041, China
- West China Biomedical Big Data Center, West China Hospital, Sichuan University, Chengdu, Sichuan, 610041, P.R. China
| | - Kang Li
- West China Biomedical Big Data Center, West China Hospital, Sichuan University, Chengdu, Sichuan, 610041, P.R. China.
- Med-X Center for Informatics, Sichuan University, Chengdu, Sichuan, 610041, P.R. China.
| | - Yong Nie
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, 610041, China.
| | - Bin Shen
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, 610041, China
| |
Collapse
|
4
|
Costăchescu B, Niculescu AG, Grumezescu AM, Teleanu DM. Screw Osteointegration-Increasing Biomechanical Resistance to Pull-Out Effect. MATERIALS (BASEL, SWITZERLAND) 2023; 16:5582. [PMID: 37629873 PMCID: PMC10456840 DOI: 10.3390/ma16165582] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2023] [Revised: 08/03/2023] [Accepted: 08/09/2023] [Indexed: 08/27/2023]
Abstract
Spinal disorders cover a broad spectrum of pathologies and are among the most prevalent medical conditions. The management of these health issues was noted to be increasingly based on surgical interventions. Spinal fixation devices are often employed to improve surgery outcomes, increasing spinal stability, restoring structural integrity, and ensuring functionality. However, most of the currently used fixation tools are fabricated from materials with very different mechanical properties to native bone that are prone to pull-out effects or fail over time, requiring revision procedures. Solutions to these problems presently exploited in practice include the optimal selection of screw shape and size, modification of insertion trajectory, and utilization of bone cement to reinforce fixation constructs. Nevertheless, none of these methods are without risks and limitations. An alternative option to increasing biomechanical resistance to the pull-out effect is to tackle bone regenerative capacity and focus on screw osteointegration properties. Osteointegration was reportedly enhanced through various optimization strategies, including use of novel materials, surface modification techniques (e.g., application of coatings and topological optimization), and utilization of composites that allow synergistic effects between constituents. In this context, this paper takes a comprehensive path, starting with a brief presentation of spinal fixation devices, moving further to observations on how the pull-out strength can be enhanced with existing methods, and further focusing on techniques for implant osteointegration improvement.
Collapse
Affiliation(s)
- Bogdan Costăchescu
- “Gr. T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania;
- “Prof. Dr. N. Oblu” Emergency Clinical Hospital, 700309 Iasi, Romania
| | - Adelina-Gabriela Niculescu
- Research Institute of the University of Bucharest—ICUB, University of Bucharest, 050657 Bucharest, Romania;
- Department of Science and Engineering of Oxide Materials and Nanomaterials, Politehnica University of Bucharest, 011061 Bucharest, Romania
| | - Alexandru Mihai Grumezescu
- Research Institute of the University of Bucharest—ICUB, University of Bucharest, 050657 Bucharest, Romania;
- Department of Science and Engineering of Oxide Materials and Nanomaterials, Politehnica University of Bucharest, 011061 Bucharest, Romania
- Academy of Romanian Scientists, Ilfov No. 3, 050044 Bucharest, Romania
| | | |
Collapse
|
5
|
Additively manufactured controlled porous orthopedic joint replacement designs to reduce bone stress shielding: a systematic review. J Orthop Surg Res 2023; 18:42. [PMID: 36647070 PMCID: PMC9841707 DOI: 10.1186/s13018-022-03492-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Accepted: 12/30/2022] [Indexed: 01/18/2023] Open
Abstract
BACKGROUND Total joint replacements are an established treatment for patients suffering from reduced mobility and pain due to severe joint damage. Aseptic loosening due to stress shielding is currently one of the main reasons for revision surgery. As this phenomenon is related to a mismatch in mechanical properties between implant and bone, stiffness reduction of implants has been of major interest in new implant designs. Facilitated by modern additive manufacturing technologies, the introduction of porosity into implant materials has been shown to enable significant stiffness reduction; however, whether these devices mitigate stress-shielding associated complications or device failure remains poorly understood. METHODS In this systematic review, a broad literature search was conducted in six databases (Scopus, Web of Science, Medline, Embase, Compendex, and Inspec) aiming to identify current design approaches to target stress shielding through controlled porous structures. The search keywords included 'lattice,' 'implant,' 'additive manufacturing,' and 'stress shielding.' RESULTS After the screening of 2530 articles, a total of 46 studies were included in this review. Studies focusing on hip, knee, and shoulder replacements were found. Three porous design strategies were identified, specifically uniform, graded, and optimized designs. The latter included personalized design approaches targeting stress shielding based on patient-specific data. All studies reported a reduction of stress shielding achieved by the presented design. CONCLUSION Not all studies used quantitative measures to describe the improvements, and the main stress shielding measures chosen varied between studies. However, due to the nature of the optimization approaches, optimized designs were found to be the most promising. Besides the stiffness reduction, other factors such as mechanical strength can be considered in the design on a patient-specific level. While it was found that controlled porous designs are overall promising to reduce stress shielding, further research and clinical evidence are needed to determine the most superior design approach for total joint replacement implants.
Collapse
|
6
|
Davoodi E, Montazerian H, Mirhakimi AS, Zhianmanesh M, Ibhadode O, Shahabad SI, Esmaeilizadeh R, Sarikhani E, Toorandaz S, Sarabi SA, Nasiri R, Zhu Y, Kadkhodapour J, Li B, Khademhosseini A, Toyserkani E. Additively manufactured metallic biomaterials. Bioact Mater 2022; 15:214-249. [PMID: 35386359 PMCID: PMC8941217 DOI: 10.1016/j.bioactmat.2021.12.027] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Revised: 12/17/2021] [Accepted: 12/21/2021] [Indexed: 02/06/2023] Open
Abstract
Metal additive manufacturing (AM) has led to an evolution in the design and fabrication of hard tissue substitutes, enabling personalized implants to address each patient's specific needs. In addition, internal pore architectures integrated within additively manufactured scaffolds, have provided an opportunity to further develop and engineer functional implants for better tissue integration, and long-term durability. In this review, the latest advances in different aspects of the design and manufacturing of additively manufactured metallic biomaterials are highlighted. After introducing metal AM processes, biocompatible metals adapted for integration with AM machines are presented. Then, we elaborate on the tools and approaches undertaken for the design of porous scaffold with engineered internal architecture including, topology optimization techniques, as well as unit cell patterns based on lattice networks, and triply periodic minimal surface. Here, the new possibilities brought by the functionally gradient porous structures to meet the conflicting scaffold design requirements are thoroughly discussed. Subsequently, the design constraints and physical characteristics of the additively manufactured constructs are reviewed in terms of input parameters such as design features and AM processing parameters. We assess the proposed applications of additively manufactured implants for regeneration of different tissue types and the efforts made towards their clinical translation. Finally, we conclude the review with the emerging directions and perspectives for further development of AM in the medical industry.
Collapse
Affiliation(s)
- Elham Davoodi
- Multi-Scale Additive Manufacturing (MSAM) Laboratory, Mechanical and Mechatronics Engineering Department, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
- Department of Bioengineering, University of California, Los Angeles, California 90095, United States
- California NanoSystems Institute (CNSI), University of California, Los Angeles, California 90095, United States
- Terasaki Institute for Biomedical Innovation, Los Angeles, California 90024, United States
| | - Hossein Montazerian
- Department of Bioengineering, University of California, Los Angeles, California 90095, United States
- California NanoSystems Institute (CNSI), University of California, Los Angeles, California 90095, United States
- Terasaki Institute for Biomedical Innovation, Los Angeles, California 90024, United States
| | - Anooshe Sadat Mirhakimi
- Department of Mechanical Engineering, Isfahan University of Technology, Isfahan, Isfahan 84156-83111, Iran
| | - Masoud Zhianmanesh
- School of Biomedical Engineering, University of Sydney, Sydney, New South Wales 2006, Australia
| | - Osezua Ibhadode
- Multi-Scale Additive Manufacturing (MSAM) Laboratory, Mechanical and Mechatronics Engineering Department, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Shahriar Imani Shahabad
- Multi-Scale Additive Manufacturing (MSAM) Laboratory, Mechanical and Mechatronics Engineering Department, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Reza Esmaeilizadeh
- Multi-Scale Additive Manufacturing (MSAM) Laboratory, Mechanical and Mechatronics Engineering Department, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Einollah Sarikhani
- Department of Nanoengineering, Jacobs School of Engineering, University of California, San Diego, California 92093, United States
| | - Sahar Toorandaz
- Multi-Scale Additive Manufacturing (MSAM) Laboratory, Mechanical and Mechatronics Engineering Department, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Shima A. Sarabi
- Mechanical and Aerospace Engineering Department, University of California, Los Angeles, California 90095, United States
| | - Rohollah Nasiri
- Terasaki Institute for Biomedical Innovation, Los Angeles, California 90024, United States
| | - Yangzhi Zhu
- Terasaki Institute for Biomedical Innovation, Los Angeles, California 90024, United States
| | - Javad Kadkhodapour
- Department of Mechanical Engineering, Shahid Rajaee Teacher Training University, Tehran, Tehran 16785-163, Iran
- Institute for Materials Testing, Materials Science and Strength of Materials, University of Stuttgart, Stuttgart 70569, Germany
| | - Bingbing Li
- Terasaki Institute for Biomedical Innovation, Los Angeles, California 90024, United States
- Department of Manufacturing Systems Engineering and Management, California State University, Northridge, California 91330, United States
| | - Ali Khademhosseini
- Terasaki Institute for Biomedical Innovation, Los Angeles, California 90024, United States
| | - Ehsan Toyserkani
- Multi-Scale Additive Manufacturing (MSAM) Laboratory, Mechanical and Mechatronics Engineering Department, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
7
|
Abstract
Ti-6Al-4V (Ti64) alloy is one of the most widely used orthopedic implant materials due to its mechanical properties, corrosion resistance, and biocompatibility nature. Porous Ti64 structures are gaining more research interest as bone implants as they can help in reducing the stress-shielding effect when compared to their solid counterpart. The literature shows that porous Ti64 implants fabricated using different additive manufacturing (AM) process routes, such as laser powder bed fusion (L-PBF) and electron beam melting (EBM) can be tailored to mimic the mechanical properties of natural bone. This review paper categorizes porous implant designs into non-gradient (uniform) and gradient (non-uniform) porous structures. Gradient porous design appears to be more promising for orthopedic applications due to its closeness towards natural bone morphology and improved mechanical properties. In addition, this paper outlines the details on bone structure and its properties, mechanical properties, fatigue behavior, multifunctional porous implant designs, current challenges, and literature gaps in the research studies on porous Ti64 bone implants.
Collapse
|
8
|
Koike M, Mitchell RJ, Horie T, Hummel SK, Okabe T. Biofilm accumulation on additive manufactured Ti-6Al-4V alloy surfaces. J Oral Sci 2022; 64:139-144. [DOI: 10.2334/josnusd.21-0521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Affiliation(s)
- Mari Koike
- The Nippon Dental University College at Tokyo, The Nippon Dental University
| | - Richard J. Mitchell
- Department of Biomaterials Science, University of Kentucky College of Dentistry
| | - Tetsuro Horie
- Department of Oral Health, The Nippon Dental University
| | | | - Toru Okabe
- Department of Biomaterials Science, Texas A & M University, Baylor College of Dentistry
| |
Collapse
|
9
|
Fong JSL, Booth MA, Rifai A, Fox K, Gelmi A. Diamond in the Rough: Toward Improved Materials for the Bone-Implant Interface. Adv Healthc Mater 2021; 10:e2100007. [PMID: 34170623 DOI: 10.1002/adhm.202100007] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2021] [Revised: 05/17/2021] [Indexed: 01/16/2023]
Abstract
The ability of an orthopedic implant to integrate successfully with the surrounding bone tissue is imperative for optimal patient outcomes. Here, the recent advances and future prospects for diamond-based coatings of conventional osteo-implant materials (primarily titanium) are explored. The ability of these diamond coatings to enhance integration into existing bone, improved implant mechanical properties, facilitate surface chemical functionalization, and provide anti-microbial properties are discussed in context of orthopedic implants. These diamond-based materials may have the additional benefit of providing an osteo-inductive effect, enabling better integration into existing bone via stem cell recruitment and bone regeneration. Current and timely research is highlighted to support the discussion and suggestions in further improving implant integration via an osseoinductive effect from the diamond composite materials.
Collapse
Affiliation(s)
- Jessica S L Fong
- School of Science, RMIT University, Melbourne, VIC, 3000, Australia
| | - Marsilea A Booth
- School of Engineering, RMIT University, Melbourne, VIC, 3000, Australia
| | - Aaqil Rifai
- School of Engineering, RMIT University, Melbourne, VIC, 3000, Australia
- School of Medicine, Deakin University, Waurn Ponds, VIC, 3216, Australia
| | - Kate Fox
- School of Engineering, RMIT University, Melbourne, VIC, 3000, Australia
| | - Amy Gelmi
- School of Science, RMIT University, Melbourne, VIC, 3000, Australia
| |
Collapse
|
10
|
Abstract
Implant-associated infections (IAIs) are among the most intractable and costly complications in implant surgery. They can lead to surgery failure, a high economic burden, and a decrease in patient quality of life. This manuscript is devoted to introducing current antimicrobial strategies for additively manufactured (AM) titanium (Ti) implants and fostering a better understanding in order to pave the way for potential modern high-throughput technologies. Most bactericidal strategies rely on implant structure design and surface modification. By means of rational structural design, the performance of AM Ti implants can be improved by maintaining a favorable balance between the mechanical, osteogenic, and antibacterial properties. This subject becomes even more important when working with complex geometries; therefore, it is necessary to select appropriate surface modification techniques, including both topological and chemical modification. Antibacterial active metal and antibiotic coatings are among the most commonly used chemical modifications in AM Ti implants. These surface modifications can successfully inhibit bacterial adhesion and biofilm formation, and bacterial apoptosis, leading to improved antibacterial properties. As a result of certain issues such as drug resistance and cytotoxicity, the development of novel and alternative antimicrobial strategies is urgently required. In this regard, the present review paper provides insights into the enhancement of bactericidal properties in AM Ti implants.
Collapse
|
11
|
Oskolkov A, Bezukladnikov I, Trushnikov D. Indirect Temperature Measurement in High Frequency Heating Systems. SENSORS 2021; 21:s21072561. [PMID: 33917461 PMCID: PMC8038681 DOI: 10.3390/s21072561] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Revised: 02/28/2021] [Accepted: 03/31/2021] [Indexed: 12/17/2022]
Abstract
One of the biggest challenges of fused deposition modeling (FDM)/fused filament fabrication (FFF) 3D-printing is maintaining consistent quality of layer-to-layer adhesion, and on the larger scale, homogeneity of material inside the whole printed object. An approach for mitigating and/or resolving those problems, based on the rapid and reliable control of the extruded material temperature during the printing process, was proposed. High frequency induction heating of the nozzle with a minimum mass (<1 g) was used. To ensure the required dynamic characteristics of heating and cooling processes in a high power (peak power > 300 W) heating system, an indirect (eddy current) temperature measurement method was proposed. It is based on dynamic analysis over various temperature-dependent parameters directly in the process of heating. To ensure better temperature measurement accuracy, a series-parallel resonant circuit containing an induction heating coil, an approach of desired signal detection, algorithms for digital signal processing and a regression model that determines the dependence of the desired signal on temperature and magnetic field strength were proposed. The testbed system designed to confirm the results of the conducted research showed the effectiveness of the proposed indirect measurement method. With an accuracy of ±3 °C, the measurement time is 20 ms in the operating temperature range from 50 to 350 °C. The designed temperature control system based on an indirect measurement method will provide high mechanical properties and consistent quality of printed objects.
Collapse
Affiliation(s)
- Alexander Oskolkov
- Department of Welding Production, Metrology and Technology of Material, Perm National Research Polytechnic University, 29 Komsomolsky Prospect, 614990 Perm, Russia;
- Correspondence:
| | - Igor Bezukladnikov
- Department of Automation and Telemechanics, Perm National Research Polytechnic University, 29 Komsomolsky Prospect, 614990 Perm, Russia;
| | - Dmitriy Trushnikov
- Department of Welding Production, Metrology and Technology of Material, Perm National Research Polytechnic University, 29 Komsomolsky Prospect, 614990 Perm, Russia;
| |
Collapse
|