1
|
Paradigms in Fluorescence Molecular Imaging: Maximizing Measurement of Biological Changes in Disease, Therapeutic Efficacy, and Toxicology/Safety. Mol Imaging Biol 2020; 21:599-611. [PMID: 30218390 DOI: 10.1007/s11307-018-1273-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Fluorescence molecular imaging (MI) is an important concept in preclinical research that focuses on the visualization of cellular and biological function in a non-invasive fashion to better understand in vivo disease processes and treatment effects. MI differs fundamentally from traditional preclinical imaging strategies in that it generally relies on reporter probes specific for particular targets or pathways that can be used to reveal biological changes in situ, at the site(s) of disease. In contrast, the more established imaging modalities, like magnetic resonance imaging, X-ray, micro X-ray computed tomography, and ultrasound, historically have relied primarily on late-stage anatomical or physiologic changes. The practical application of fluorescence MI, however, has drifted somewhat from the emphasis on quantifying biology, and based on the publication record, it now appears to include any imaging in which a probe or contrast agent is used to non-invasively acquire in vivo endpoint information. Unfortunately, the mere use of a defined biologically specific probe, in the absence of careful study design, does not guarantee that any useful biological information is actually gained, although often useful endpoint results still can be achieved. This review proposes to add subcategories of MI, termed MI biological assessment (or MIBA), that emphasize a focus on obtaining early and clear biological changes associated with disease development, therapeutic efficacy, and drug-induced tissue changes. Proper selection of probes and careful study design are critical for maximizing the non-invasive assessment of in vivo biological changes, and applications of these critical elements are described.
Collapse
|
2
|
Hien A, Pretze M, Braun F, Schäfer E, Kümmel T, Roscher M, Schock-Kusch D, Waldeck J, Müller B, Wängler C, Rädle M, Wängler B. Noncontact recognition of fluorescently labeled objects in deep tissue via a novel optical light beam arrangement. PLoS One 2018; 13:e0208236. [PMID: 30566459 PMCID: PMC6300195 DOI: 10.1371/journal.pone.0208236] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2018] [Accepted: 11/14/2018] [Indexed: 12/30/2022] Open
Abstract
To date, few optical imaging systems are available in clinical practice to perform noninvasive measurements transcutaneously. Instead, functional imaging is performed using ionizing radiation or intense magnetic fields in most cases. The applicability of fluorescence imaging (e.g., for the detection of fluorescently labeled objects, such as tumors) is limited due to the restricted tissue penetration of light and the required long exposure time. Thus, the development of highly sensitive and easily manageable instruments is necessary to broaden the utility of optical imaging. To advance these developments, an improved fluorescence imaging system was designed in this study that operates on the principle of noncontact laser-induced fluorescence and enables the detection of fluorescence from deeper tissue layers as well as real-time imaging. The high performance of the developed optical laser scanner results from the combination of specific point illumination, an intensified charge-coupled device (ICCD) detector with a novel light trap, and a filtering strategy. The suitability of the laser scanner was demonstrated in two representative applications and an in vivo evaluation. In addition, a comparison with a planar imaging system was performed. The results show that the exposure time with the developed laser scanner can be reduced to a few milliseconds during measurements with a penetration depth of up to 32 mm. Due to these short exposure times, real-time fluorescence imaging can be easily achieved. The ability to measure fluorescence from deep tissue layers enables clinically relevant applications, such as the detection of fluorescently labeled malignant tumors.
Collapse
Affiliation(s)
- Andreas Hien
- Institute of Process Control and Innovative Energy Conversion, Mannheim University of Applied Sciences, Mannheim, Germany
- * E-mail:
| | - Marc Pretze
- Molecular Imaging and Radiochemistry, Department of Clinical Radiology and Nuclear Medicine, Medical Faculty Mannheim of Heidelberg University, Mannheim, Germany
| | - Frank Braun
- Institute of Process Control and Innovative Energy Conversion, Mannheim University of Applied Sciences, Mannheim, Germany
| | - Edgar Schäfer
- Institute of Process Control and Innovative Energy Conversion, Mannheim University of Applied Sciences, Mannheim, Germany
| | - Tim Kümmel
- Institute of Process Control and Innovative Energy Conversion, Mannheim University of Applied Sciences, Mannheim, Germany
| | - Mareike Roscher
- Molecular Imaging and Radiochemistry, Department of Clinical Radiology and Nuclear Medicine, Medical Faculty Mannheim of Heidelberg University, Mannheim, Germany
| | - Daniel Schock-Kusch
- Institute of Process Control and Innovative Energy Conversion, Mannheim University of Applied Sciences, Mannheim, Germany
| | | | | | - Carmen Wängler
- Biomedical Chemistry, Department of Clinical Radiology and Nuclear Medicine, Medical Faculty Mannheim of Heidelberg University, Mannheim, Germany
| | - Matthias Rädle
- Institute of Process Control and Innovative Energy Conversion, Mannheim University of Applied Sciences, Mannheim, Germany
| | - Björn Wängler
- Molecular Imaging and Radiochemistry, Department of Clinical Radiology and Nuclear Medicine, Medical Faculty Mannheim of Heidelberg University, Mannheim, Germany
| |
Collapse
|
3
|
Vasquez KO, Peterson JD. Early Detection of Acute Drug-Induced Liver Injury in Mice by Noninvasive Near-Infrared Fluorescence Imaging. J Pharmacol Exp Ther 2017; 361:87-98. [PMID: 28115551 PMCID: PMC5363778 DOI: 10.1124/jpet.116.238378] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2016] [Accepted: 01/18/2017] [Indexed: 01/05/2023] Open
Abstract
Hepatocellular and cholestatic forms of drug-induced liver injury (DILI) are major reasons for late-stage termination of small-molecule drug discovery research projects. Biochemical serum markers are limited in their ability to sensitively and specifically detect both of these common DILI forms in preclinical models, and tissue-specific approaches to assessing this are labor intensive, requiring extensive animal dosing, tissue preparation, and pathology assessment. In vivo fluorescent imaging offers noninvasive detection of biologic changes detected directly in the livers of living animals. Three different near-infrared fluorescent imaging probes, specific for cell death (Annexin-Vivo 750), matrix metalloproteases (MMPSense 750 FAST), and transferrin receptor (Transferrin-Vivo 750) were used to measure the effects of single bolus intraperitoneal doses of four different chemical agents known to induce liver injury. Hepatocellular injury–inducing agents, thioacetamide and acetaminophen, showed optimal injury detection with probe injection at 18–24 hours, the liver cholestasis-inducing drug rifampicin required early probe injection (2 hours), and chlorpromazine, which induces mixed hepatocellular/cholestatic injury, showed injury with both early and late injection. Different patterns of liver responses were seen among these different imaging probes, and no one probe detected injury by all four compounds. By using a cocktail of these three near-infrared fluorescent imaging probes, all labeled with 750-nm fluorophores, each of the four different DILI agents induced comparable tissue injury within the liver region, as assessed by epifluorescence imaging. A strategy of probe cocktail injection in separate cohorts at 2 hours and at 20–24 hours allowed the effective detection of drugs with either early- or late-onset injury.
Collapse
|
4
|
Lunardi CN, Gomes AJ, Palepu S, Galwaduge PT, Hillman EM. PLGA nano/microparticles loaded with cresyl violet as a tracer for drug delivery: Characterization and in-situ hyperspectral fluorescence and 2-photon localization. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 70:505-511. [DOI: 10.1016/j.msec.2016.09.020] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2016] [Revised: 08/24/2016] [Accepted: 09/06/2016] [Indexed: 01/14/2023]
|
5
|
Zhang G, Pu H, He W, Liu F, Luo J, Bai J. Bayesian Framework Based Direct Reconstruction of Fluorescence Parametric Images. IEEE TRANSACTIONS ON MEDICAL IMAGING 2015; 34:1378-1391. [PMID: 25622312 DOI: 10.1109/tmi.2015.2394476] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Fluorescence imaging has been successfully used in the study of pharmacokinetic analysis, while dynamic fluorescence molecular tomography (FMT) is an attractive imaging technique for three-dimensionally resolving the metabolic process of fluorescent biomarkers in small animals in vivo. Parametric images obtained by combining dynamic FMT with compartmental modeling can provide quantitative physiological information for biological studies and drug development. However, images obtained with conventional indirect methods suffer from poor image quality because of failure in utilizing the temporal correlations of boundary measurements. Besides, FMT suffers from low spatial resolution due to its ill-posed nature, which further reduces the image quality. In this paper, we propose a novel method to directly reconstruct parametric images from boundary measurements based on maximum a posteriori (MAP) estimation with structural priors in a Bayesian framework. The proposed method can utilize structural priors obtained from an X-ray computed tomography system to mitigate the ill-posedness of dynamic FMT inverse problem, and use direct reconstruction strategy to make full use of temporal correlations of boundary measurements. The results of numerical simulations and in vivo mouse experiments demonstrate that the proposed method leads to significant improvements in the reconstruction quality of parametric images as compared with the conventional indirect method and a previously developed direct method.
Collapse
|
6
|
Zhang G, He W, Pu H, Liu F, Chen M, Bai J, Luo J. Acceleration of dynamic fluorescence molecular tomography with principal component analysis. BIOMEDICAL OPTICS EXPRESS 2015; 6:2036-55. [PMID: 26114027 PMCID: PMC4473742 DOI: 10.1364/boe.6.002036] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2015] [Revised: 04/30/2015] [Accepted: 05/04/2015] [Indexed: 05/24/2023]
Abstract
Dynamic fluorescence molecular tomography (FMT) is an attractive imaging technique for three-dimensionally resolving the metabolic process of fluorescent biomarkers in small animal. When combined with compartmental modeling, dynamic FMT can be used to obtain parametric images which can provide quantitative pharmacokinetic information for drug development and metabolic research. However, the computational burden of dynamic FMT is extremely huge due to its large data sets arising from the long measurement process and the densely sampling device. In this work, we propose to accelerate the reconstruction process of dynamic FMT based on principal component analysis (PCA). Taking advantage of the compression property of PCA, the dimension of the sub weight matrix used for solving the inverse problem is reduced by retaining only a few principal components which can retain most of the effective information of the sub weight matrix. Therefore, the reconstruction process of dynamic FMT can be accelerated by solving the smaller scale inverse problem. Numerical simulation and mouse experiment are performed to validate the performance of the proposed method. Results show that the proposed method can greatly accelerate the reconstruction of parametric images in dynamic FMT almost without degradation in image quality.
Collapse
Affiliation(s)
- Guanglei Zhang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
- Department of Biomedical Engineering, School of Computer and Information Technology, Beijing Jiaotong University, Beijing 100044, China
| | - Wei He
- China Institute of Sport Science, Beijing 100061, China
| | - Huangsheng Pu
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Fei Liu
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
- Tsinghua-Peking Center for Life Sciences, Beijing 100084, China
| | - Maomao Chen
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Jing Bai
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Jianwen Luo
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
- Center for Biomedical Imaging Research, Tsinghua University, Beijing 100084, China
| |
Collapse
|