1
|
Eleni Karakatsani M, Estrada H, Chen Z, Shoham S, Deán-Ben XL, Razansky D. Shedding light on ultrasound in action: Optical and optoacoustic monitoring of ultrasound brain interventions. Adv Drug Deliv Rev 2024; 205:115177. [PMID: 38184194 PMCID: PMC11298795 DOI: 10.1016/j.addr.2023.115177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 12/27/2023] [Accepted: 12/31/2023] [Indexed: 01/08/2024]
Abstract
Monitoring brain responses to ultrasonic interventions is becoming an important pillar of a growing number of applications employing acoustic waves to actuate and cure the brain. Optical interrogation of living tissues provides a unique means for retrieving functional and molecular information related to brain activity and disease-specific biomarkers. The hybrid optoacoustic imaging methods have further enabled deep-tissue imaging with optical contrast at high spatial and temporal resolution. The marriage between light and sound thus brings together the highly complementary advantages of both modalities toward high precision interrogation, stimulation, and therapy of the brain with strong impact in the fields of ultrasound neuromodulation, gene and drug delivery, or noninvasive treatments of neurological and neurodegenerative disorders. In this review, we elaborate on current advances in optical and optoacoustic monitoring of ultrasound interventions. We describe the main principles and mechanisms underlying each method before diving into the corresponding biomedical applications. We identify areas of improvement as well as promising approaches with clinical translation potential.
Collapse
Affiliation(s)
- Maria Eleni Karakatsani
- Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Switzerland; Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Switzerland
| | - Héctor Estrada
- Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Switzerland; Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Switzerland
| | - Zhenyue Chen
- Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Switzerland; Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Switzerland
| | - Shy Shoham
- Department of Ophthalmology and Tech4Health and Neuroscience Institutes, NYU Langone Health, NY, USA
| | - Xosé Luís Deán-Ben
- Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Switzerland; Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Switzerland.
| | - Daniel Razansky
- Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Switzerland; Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Switzerland.
| |
Collapse
|
2
|
Impact of fluorescent dyes on the physicochemical parameters of microbubbles stabilized by albumin-dye complex. Colloids Surf A Physicochem Eng Asp 2022. [DOI: 10.1016/j.colsurfa.2022.129095] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
3
|
Spatarelu CP, Van Namen A, Jandhyala S, Luke GP. Fluorescent Phase-Changing Perfluorocarbon Nanodroplets as Activatable Near-Infrared Probes. Int J Mol Sci 2022; 23:ijms23137312. [PMID: 35806326 PMCID: PMC9266996 DOI: 10.3390/ijms23137312] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Revised: 06/27/2022] [Accepted: 06/29/2022] [Indexed: 02/01/2023] Open
Abstract
The sensitivity of fluorescence imaging is limited by the high optical scattering of tissue. One approach to improve sensitivity to small signals is to use a contrast agent with a signal that can be externally modulated. In this work, we present a new phase-changing perfluorocarbon nanodroplet contrast agent loaded with DiR dye. The nanodroplets undergo a liquid-to-gas phase transition when exposed to an externally applied laser pulse. This results in the unquenching of the encapsulated dye, thus increasing the fluorescent signal, a phenomenon that can be characterized by an ON/OFF ratio between the fluorescence of activated and nonactivated nanodroplets, respectively. We investigate and optimize the quenching/unquenching of DiR upon nanodroplets’ vaporization in suspension, tissue-mimicking phantoms and a subcutaneous injection mouse model. We also demonstrate that the vaporized nanodroplets produce ultrasound contrast, enabling multimodal imaging. This work shows that these nanodroplets could be applied to imaging applications where high sensitivity is required.
Collapse
Affiliation(s)
| | - Austin Van Namen
- Dartmouth College, 15 Thayer Drive, Hanover, NH 03755, USA; (C.-P.S.); (A.V.N.); (S.J.)
| | - Sidhartha Jandhyala
- Dartmouth College, 15 Thayer Drive, Hanover, NH 03755, USA; (C.-P.S.); (A.V.N.); (S.J.)
| | - Geoffrey P. Luke
- Dartmouth College, 15 Thayer Drive, Hanover, NH 03755, USA; (C.-P.S.); (A.V.N.); (S.J.)
- Norris Cotton Cancer Center, 1 Medical Center Drive, Lebanon, NH 03766, USA
- Correspondence:
| |
Collapse
|
4
|
|
5
|
Stride E, Segers T, Lajoinie G, Cherkaoui S, Bettinger T, Versluis M, Borden M. Microbubble Agents: New Directions. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:1326-1343. [PMID: 32169397 DOI: 10.1016/j.ultrasmedbio.2020.01.027] [Citation(s) in RCA: 107] [Impact Index Per Article: 21.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2019] [Revised: 01/09/2020] [Accepted: 01/26/2020] [Indexed: 05/24/2023]
Abstract
Microbubble ultrasound contrast agents have now been in use for several decades and their safety and efficacy in a wide range of diagnostic applications have been well established. Recent progress in imaging technology is facilitating exciting developments in techniques such as molecular, 3-D and super resolution imaging and new agents are now being developed to meet their specific requirements. In parallel, there have been significant advances in the therapeutic applications of microbubbles, with recent clinical trials demonstrating drug delivery across the blood-brain barrier and into solid tumours. New agents are similarly being tailored toward these applications, including nanoscale microbubble precursors offering superior circulation times and tissue penetration. The development of novel agents does, however, present several challenges, particularly regarding the regulatory framework. This article reviews the developments in agents for diagnostic, therapeutic and "theranostic" applications; novel manufacturing techniques; and the opportunities and challenges for their commercial and clinical translation.
Collapse
Affiliation(s)
- Eleanor Stride
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, UK.
| | - Tim Segers
- Physics of Fluids Group, Technical Medical (TechMed) Centre, MESA+ Institute for Nanotechnology, University of Twente, The Netherlands
| | - Guillaume Lajoinie
- Physics of Fluids Group, Technical Medical (TechMed) Centre, MESA+ Institute for Nanotechnology, University of Twente, The Netherlands
| | - Samir Cherkaoui
- Bracco Suisse SA - Business Unit Imaging, Global R&D, Plan-les-Ouates, Switzerland
| | - Thierry Bettinger
- Bracco Suisse SA - Business Unit Imaging, Global R&D, Plan-les-Ouates, Switzerland
| | - Michel Versluis
- Physics of Fluids Group, Technical Medical (TechMed) Centre, MESA+ Institute for Nanotechnology, University of Twente, The Netherlands
| | - Mark Borden
- Mechanical Engineering Department, University of Colorado, Boulder, CO, USA
| |
Collapse
|
6
|
An ICCD camera-based time-domain ultrasound-switchable fluorescence imaging system. Sci Rep 2019; 9:10552. [PMID: 31332236 PMCID: PMC6646316 DOI: 10.1038/s41598-019-47156-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Accepted: 07/11/2019] [Indexed: 12/20/2022] Open
Abstract
Fluorescence imaging in centimeter-deep tissues with high resolution is highly desirable for many biomedical applications. Recently, we have developed a new imaging modality, ultrasound-switchable fluorescence (USF) imaging, for achieving this goal. In our previous work, we successfully achieved USF imaging with several types of USF contrast agents and imaging systems. In this study, we introduced a new USF imaging system: an intensified charge-coupled device (ICCD) camera-based, time-domain USF imaging system. We demonstrated the principle of time-domain USF imaging by using two USF contrast agents. With a series of USF imaging experiments, we demonstrated the tradeoffs among different experimental parameters (i.e., data acquisition time, including CCD camera recording time and intensifier gate delay; focused ultrasound (FU) power; and imaging depth) and the image qualities (i.e., signal-to-noise ratio, spatial resolution, and temporal resolution). In this study, we also discussed several imaging strategies for achieving a high-quality USF image via this time-domain system.
Collapse
|
7
|
Pei Y, Wei MY. Newly-Engineered Materials for Bio-Imaging Technology: A Focus on the Hybrid System of Ultrasound and Fluorescence. Front Bioeng Biotechnol 2019; 7:88. [PMID: 31080797 PMCID: PMC6497727 DOI: 10.3389/fbioe.2019.00088] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2019] [Accepted: 04/09/2019] [Indexed: 11/18/2022] Open
Abstract
As an emerging technique, ultrasound-modulated fluorescence (UMF), or ultrasound switchable fluorescence (USF) bioimaging has shown promising features to produce deep-tissue and high-resolution fluorescence imaging for biomedical research and health diagnosis. The success of UMF or USF heavily relies on the design of their contrast agents (CAs). We herein surveyed recent advances in the development of such unique CAs, including configuration, mechanism, stability, sensitivity, and selectivity. Meanwhile, UMF or USF instrumentation has emerged as developmental breakthrough technologies to existing bio-imaging techniques. The best performance of UMF or USF bio-imaging requires an interactive response between CAs and the instrument. In this review, the description of UMF or USF instrumentation are also included for clarification and better understanding. Finally, the UMF and USF's performance in bioimaging is evaluated based on signal-to-noise ratio, resolution, imaging depth and speed, using photoacoustic imaging (PAI) as a standard, a well-developed technique of hybrid bio-imaging. Unlike PAI, UMF or USF is still in its early stage. Although results demonstrated a proof-of-concept landmark being reached, significant efforts are needed to improve the performance of UMF or USF.
Collapse
Affiliation(s)
- Yanbo Pei
- Department of Physics, Harbin Institute of Technology, Harbin, China
| | - Ming-Yuan Wei
- Texas Commission on Environmental Quality, Fort Worth, TX, United States
| |
Collapse
|
8
|
Li Y, Chen Y, Du M, Chen ZY. Ultrasound Technology for Molecular Imaging: From Contrast Agents to Multimodal Imaging. ACS Biomater Sci Eng 2018; 4:2716-2728. [PMID: 33434997 DOI: 10.1021/acsbiomaterials.8b00421] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Ultrasound (US) takes advantage of ultrasound contrast agents (UCAs) to further increase the sensitivity and specificity of monitoring at the cellular level, which has had a considerable effect on the modern molecular imaging field. Gas-filled microbubbles (MBs) as UCAs in the bloodstream generate resonant volumetric oscillations in response to rapid variations in acoustic pressure, which are related to both the acoustic parameters of applied ultrasound and the physicochemical properties of the contrast agents. Nanoscale UCAs have been developed and have attracted much attention due to their utility in detecting extravascular lesions. Ultrasound molecular assessment is achieved by binding disease-specific ligands to the surface of UCAs, which have been designed to target tissue biomarkers in the area of interest, such as blood vessels, inflammation, or thrombosis. Additionally, the development of multimodal imaging technology is conducive for integration of the advantages of various imaging techniques to acquire additional diagnostic information. In this review paper, the present status and the critical issues for developing ultrasound contrast agents and multimodal imaging applications are described. Conventional MB UCAs are first introduced, including their research material, diagnostic applications, and intrinsic limitations. Then, recent progress in developing targeted UCAs and phase-inversion contrast agents for diagnostic purposes is discussed. Finally, we review the present status and the critical issues for developing ultrasound-based multimodal imaging applications and summarize the existing challenges and future prospects.
Collapse
Affiliation(s)
- Yue Li
- Department of Ultrasound Medicine, Laboratory of Ultrasound Molecular Imaging, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou 510150, People's Republic of China
| | - Yuhao Chen
- Department of Ultrasound Medicine, Laboratory of Ultrasound Molecular Imaging, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou 510150, People's Republic of China
| | - Meng Du
- Department of Ultrasound Medicine, Laboratory of Ultrasound Molecular Imaging, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou 510150, People's Republic of China
| | - Zhi-Yi Chen
- Department of Ultrasound Medicine, Laboratory of Ultrasound Molecular Imaging, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou 510150, People's Republic of China
| |
Collapse
|
9
|
Yu S, Cheng B, Yao T, Xu C, Nguyen KT, Hong Y, Yuan B. New generation ICG-based contrast agents for ultrasound-switchable fluorescence imaging. Sci Rep 2016; 6:35942. [PMID: 27775014 PMCID: PMC5075910 DOI: 10.1038/srep35942] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2016] [Accepted: 10/07/2016] [Indexed: 01/21/2023] Open
Abstract
Recently, we developed a new technology, ultrasound-switchable fluorescence (USF), for high-resolution imaging in centimeter-deep tissues via fluorescence contrast. The success of USF imaging highly relies on excellent contrast agents. ICG-encapsulated poly(N-isopropylacrylamide) nanoparticles (ICG-NPs) are one of the families of the most successful near-infrared (NIR) USF contrast agents. However, the first-generation ICG-NPs have a short shelf life (<1 month). This work significantly increases the shelf life of the new-generation ICG-NPs (>6 months). In addition, we have conjugated hydroxyl or carboxyl function groups on the ICG-NPs for future molecular targeting. Finally, we have demonstrated the effect of temperature-switching threshold (Tth) and the background temperature (TBG) on the quality of USF images. We estimated that the Tth of the ICG-NPs should be controlled at ~38–40 °C (slightly above the body temperature of 37 °C) for future in vivo USF imaging. Addressing these challenges further reduces the application barriers of USF imaging.
Collapse
Affiliation(s)
- Shuai Yu
- Ultrasound and Optical Imaging Laboratory, Department of Bioengineering, The University of Texas at Arlington, Arlington, TX 76019, USA.,Joint Biomedical Engineering Program, The University of Texas at Arlington and The University of Texas Southwestern Medical Center at Dallas, TX 75390, USA
| | - Bingbing Cheng
- Ultrasound and Optical Imaging Laboratory, Department of Bioengineering, The University of Texas at Arlington, Arlington, TX 76019, USA.,Joint Biomedical Engineering Program, The University of Texas at Arlington and The University of Texas Southwestern Medical Center at Dallas, TX 75390, USA
| | - Tingfeng Yao
- Ultrasound and Optical Imaging Laboratory, Department of Bioengineering, The University of Texas at Arlington, Arlington, TX 76019, USA.,Joint Biomedical Engineering Program, The University of Texas at Arlington and The University of Texas Southwestern Medical Center at Dallas, TX 75390, USA
| | - Cancan Xu
- Joint Biomedical Engineering Program, The University of Texas at Arlington and The University of Texas Southwestern Medical Center at Dallas, TX 75390, USA.,Department of Bioengineering, The University of Texas at Arlington, Arlington, TX 76019, USA
| | - Kytai T Nguyen
- Joint Biomedical Engineering Program, The University of Texas at Arlington and The University of Texas Southwestern Medical Center at Dallas, TX 75390, USA.,Department of Bioengineering, The University of Texas at Arlington, Arlington, TX 76019, USA
| | - Yi Hong
- Joint Biomedical Engineering Program, The University of Texas at Arlington and The University of Texas Southwestern Medical Center at Dallas, TX 75390, USA.,Department of Bioengineering, The University of Texas at Arlington, Arlington, TX 76019, USA
| | - Baohong Yuan
- Ultrasound and Optical Imaging Laboratory, Department of Bioengineering, The University of Texas at Arlington, Arlington, TX 76019, USA.,Joint Biomedical Engineering Program, The University of Texas at Arlington and The University of Texas Southwestern Medical Center at Dallas, TX 75390, USA
| |
Collapse
|
10
|
Zhang Q, Morgan SP, O’Shea P, Mather ML. Ultrasound Induced Fluorescence of Nanoscale Liposome Contrast Agents. PLoS One 2016; 11:e0159742. [PMID: 27467748 PMCID: PMC4965150 DOI: 10.1371/journal.pone.0159742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2015] [Accepted: 07/07/2016] [Indexed: 11/19/2022] Open
Abstract
A new imaging contrast agent is reported that provides an increased fluorescent signal upon application of ultrasound (US). Liposomes containing lipids labelled with pyrene were optically excited and the excimer fluorescence emission intensity was detected in the absence and presence of an ultrasound field using an acousto-fluorescence setup. The acousto-fluorescence dynamics of liposomes containing lipids with pyrene labelled on the fatty acid tail group (PyPC) and the head group (PyPE) were compared. An increase in excimer emission intensity following exposure to US was observed for both cases studied. The increased intensity and time constants were found to be different for the PyPC and PyPE systems, and dependent on the applied US pressure and exposure time. The greatest change in fluorescence intensity (130%) and smallest rise time constant (0.33 s) are achieved through the use of PyPC labelled liposomes. The mechanism underlying the observed increase of the excimer emission intensity in PyPC labelled liposomes is proposed to arise from the "wagging" of acyl chains which involves fast response and requires lower US pressure. This is accompanied by increased lipid lateral diffusivity at higher ultrasound pressures, a mechanism that is also active in the PyPE labelled liposomes.
Collapse
Affiliation(s)
- Qimei Zhang
- Advanced Optics Group, Faculty of Engineering, University of Nottingham, Nottingham, United Kingdom
| | - Stephen P. Morgan
- Advanced Optics Group, Faculty of Engineering, University of Nottingham, Nottingham, United Kingdom
| | - Paul O’Shea
- Cell Biophysics Group, School of Life Sciences, University of Nottingham, Nottingham, United Kingdom
| | - Melissa L. Mather
- Advanced Optics Group, Faculty of Engineering, University of Nottingham, Nottingham, United Kingdom
- Institute for Science and Technology in Medicine, Keele University, Stoke-on-Trent, United Kingdom
| |
Collapse
|
11
|
Kobayashi M, Kikuchi N, Sato A. Ultrasound-enhanced chemiluminescence tomography in biological tissue. ULTRASONICS SONOCHEMISTRY 2016; 31:1-6. [PMID: 26964918 DOI: 10.1016/j.ultsonch.2015.11.027] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2015] [Revised: 11/26/2015] [Accepted: 11/26/2015] [Indexed: 05/07/2023]
Abstract
This paper reports ultrasound-assisted optical imaging of chemiluminescent probes in biological tissue. A focused low power ultrasound sonochemically enhances a peroxyoxalate chemiluminescence (CL) that involves indocyanine green (ICG) as luminescent pigments. By scanning the focus, it produces tomographic images of CL in scattering media. The authors demonstrate imaging using a slab of porcine muscle measuring 50 × 50 × 75 mm, in which a capsuled CL reagent is embedded at 25 mm depth. Spatial resolution of imaging and concentration characteristics of CL reagents to enhanced CL intensity are also studied to evaluate the potential for use in bio-imaging applications with exploring the CL enhancement mechanisms. CL enhancement ratio, defined as the ratio of ultrasonically enhanced CL intensity to the base intensity without ultrasound irradiation, was found to be constant even in varying ICG and oxidizer concentrations, implying to be applicable for quantitative determination of these molecules.
Collapse
Affiliation(s)
- Masaki Kobayashi
- Department of Electronics and Intelligent Systems, Tohoku Institute of Technology, Sendai 982-8577, Japan.
| | - Naoto Kikuchi
- Department of Electronics and Intelligent Systems, Tohoku Institute of Technology, Sendai 982-8577, Japan
| | - Akihiro Sato
- Department of Electronics and Intelligent Systems, Tohoku Institute of Technology, Sendai 982-8577, Japan
| |
Collapse
|
12
|
Ruan H, Jang M, Yang C. Optical focusing inside scattering media with time-reversed ultrasound microbubble encoded light. Nat Commun 2015; 6:8968. [PMID: 26597439 PMCID: PMC4673873 DOI: 10.1038/ncomms9968] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2015] [Accepted: 10/22/2015] [Indexed: 12/16/2022] Open
Abstract
Focusing light inside scattering media in a freely addressable fashion is challenging, as the wavefront of the scattered light is highly disordered. Recently developed ultrasound-guided wavefront shaping methods are addressing this challenge, albeit with relatively low modulation efficiency and resolution limitations. In this paper, we present a new technique, time-reversed ultrasound microbubble encoded (TRUME) optical focusing, which can focus light with improved efficiency and sub-ultrasound wavelength resolution. This method ultrasonically destroys microbubbles, and measures the wavefront change to compute and render a suitable time-reversed wavefront solution for focusing. We demonstrate that the TRUME technique can create an optical focus at the site of bubble destruction with a size of ∼2 μm. We further demonstrate a twofold enhancement in addressable focus resolution in a microbubble aggregate target by exploiting the nonlinear pressure-to-destruction response of the microbubbles. The reported technique provides a deep tissue-focusing solution with high efficiency, resolution, and specificity. Focusing light inside biological tissue is challenging due to its strong scattering nature. Here, the authors develop a technique that uses ultrasonically destroyed microbubbles to assist in the computation of a wavefront solution which forms optical foci at the microbubble destruction sites.
Collapse
Affiliation(s)
- Haowen Ruan
- Department of Electrical Engineering, California Institute of Technology, 1200 East California Boulevard, Pasadena, California 91125, USA
| | - Mooseok Jang
- Department of Electrical Engineering, California Institute of Technology, 1200 East California Boulevard, Pasadena, California 91125, USA
| | - Changhuei Yang
- Department of Electrical Engineering, California Institute of Technology, 1200 East California Boulevard, Pasadena, California 91125, USA
| |
Collapse
|
13
|
Liu Y, Feshitan JA, Wei MY, Borden MA, Yuan B. Ultrasound-modulated fluorescence based on donor-acceptor-labeled microbubbles. JOURNAL OF BIOMEDICAL OPTICS 2015; 20:036012. [PMID: 25789423 PMCID: PMC4365896 DOI: 10.1117/1.jbo.20.3.036012] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2014] [Accepted: 03/03/2015] [Indexed: 06/04/2023]
Abstract
A fluorescence resonance energy transfer (FRET)-based microbubble contrast agent system was designed to experimentally demonstrate the concept of ultrasound-modulated fluorescence (UMF). Microbubbles were simultaneously labeled with donor and acceptor fluorophores on the surface to minimize self-quenching and maximize FRET. In response to ultrasound, the quenching efficiency was greatly modulated by changing the distance between the donor and acceptor molecules through microbubble size oscillations. Both donors and acceptors exhibited UMF on individual microbubbles. The UMF strength of the donor was more significant compared to that of the acceptor. Furthermore, the UMF of the donor was observed from a microbubble solution in a turbid media. This study exploits the feasibility of donor–acceptor labeled microbubbles as UMF contrast agents.
Collapse
Affiliation(s)
- Yuan Liu
- The University of Texas at Arlington, Department of Bioengineering, 500 UTA Boulevard, Arlington, Texas 76010, United States
- The University of Texas at Arlington and The University of Texas Southwestern Medical Center at Dallas, Joint Biomedical Engineering Program, 5323 Harry Hines Boulevard, Dallas, Texas 75390, United States
| | - Jameel A. Feshitan
- University of Colorado, Department of Mechanical Engineering, 1111 Engineering Drive, Boulder, Colorado 80309-0427, United States
| | - Ming-Yuan Wei
- The University of Texas at Arlington, Department of Bioengineering, 500 UTA Boulevard, Arlington, Texas 76010, United States
- The University of Texas at Arlington and The University of Texas Southwestern Medical Center at Dallas, Joint Biomedical Engineering Program, 5323 Harry Hines Boulevard, Dallas, Texas 75390, United States
| | - Mark A. Borden
- University of Colorado, Department of Mechanical Engineering, 1111 Engineering Drive, Boulder, Colorado 80309-0427, United States
| | - Baohong Yuan
- The University of Texas at Arlington, Department of Bioengineering, 500 UTA Boulevard, Arlington, Texas 76010, United States
- The University of Texas at Arlington and The University of Texas Southwestern Medical Center at Dallas, Joint Biomedical Engineering Program, 5323 Harry Hines Boulevard, Dallas, Texas 75390, United States
| |
Collapse
|
14
|
Cheng B, Wei MY, Liu Y, Pitta H, Xie Z, Hong Y, Nguyen KT, Yuan B. Development of Ultrasound-switchable Fluorescence Imaging Contrast Agents based on Thermosensitive Polymers and Nanoparticles. IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS : A PUBLICATION OF THE IEEE LASERS AND ELECTRO-OPTICS SOCIETY 2014; 20:6801214. [PMID: 26052192 PMCID: PMC4454428 DOI: 10.1109/jstqe.2013.2280997] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
In this work we first introduced a recently developed high-resolution, deep-tissue imaging technique, ultrasound-switchable fluorescence (USF). The imaging principles based on two types of USF contrast agents were reviewed. To improve USF imaging techniques further, excellent USF contrast agents were developed based on high-performance thermoresponsive polymers and environment-sensitive fluorophores. Herein, such contrast agents were synthesized and characterized with five key parameters: (1) peak excitation and emission wavelengths (λex and λem), (2) the fluorescence intensity ratio between on and off states (IOn/IOff), (3) the fluorescence lifetime ratio between on and off states (τOn/τOff), (4) the temperature threshold to switch on fluorophores (Tth), and (5) the temperature transition bandwidth (TBW). We mainly investigated fluorescence intensity and lifetime changes of four environment-sensitive dyes [7-(2-Aminoethylamino)-N,N-dimethyl-4-benzofurazansulfonamide (DBD-ED), St633, Sq660, and St700] as a function of temperature, while the dye was attached to poly(N-isopropylacrylamide) linear polymers or encapsulated in nanoparticles. Six fluorescence resonance energy transfer systems were invented in which both the donor (DBD-ED or ST425) and the acceptor (Sq660) were adopted. Our results indicate that three Förster resonance energy transfer systems, where both IOn/IOff and τOn/τOff are larger than 2.5, are promising for application in future surface tissue bioimaging by USF technique.
Collapse
Affiliation(s)
| | | | - Yuan Liu
- Ultrasound and Optical Imaging Laboratory, Department of Bioengineering, The University of Texas at Arlington, Arlington, TX 76010, USA
- Joint Biomedical Engineering Program, The University of Texas at Arlington and The University of Texas Southwestern Medical Center at Dallas, TX 75390, USA
| | - Harish Pitta
- Joint Biomedical Engineering Program, The University of Texas at Arlington and The University of Texas Southwestern Medical Center at Dallas, TX 75390, USA
- Department of Bioengineering, The University of Texas at Arlington, Arlington, TX 76010, USA
| | | | - Yi Hong
- Joint Biomedical Engineering Program, The University of Texas at Arlington and The University of Texas Southwestern Medical Center at Dallas, TX 75390, USA
- Department of Bioengineering, The University of Texas at Arlington, Arlington, TX 76010, USA
| | - Kytai T. Nguyen
- Joint Biomedical Engineering Program, The University of Texas at Arlington and The University of Texas Southwestern Medical Center at Dallas, TX 75390, USA
- Department of Bioengineering, The University of Texas at Arlington, Arlington, TX 76010, USA
| | - Baohong Yuan
- Corresponding author: B. Yuan, . Tel: +1-817-272-2917; FAX: +1-817-272-2251
| |
Collapse
|