1
|
Shen Y, Sun Y, Liang Y, Xu X, Su R, Wang Y, Qi W. Full-color peptide-based fluorescent nanomaterials assembled under the control of amino acid doping. NANOSCALE HORIZONS 2024; 10:158-164. [PMID: 39498619 DOI: 10.1039/d4nh00400k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/06/2024]
Abstract
Peptide-based biofluorescents are of great interest due to their controllability and biocompatibility, as well as their potential applications in biomedical imaging and biosensing. Here, we present a simple approach to synthesizing full-color fluorescent nanomaterials with broad-spectrum fluorescence emissions, high optical stability, and long fluorescence lifetimes. By doping amino acids during the enzyme-catalyzed oxidative self-assembly of tyrosine-based peptides, we can precisely control the intermolecular interactions to obtain nanoparticles with fluorescence emission at different wavelengths. The synthesized peptide-based fluorescent nanomaterials with excellent biocompatibility and stable near-infrared fluorescence emission were shown to have potential for bioimaging applications. This research provides new ideas for the development of new bioluminescent materials that are cost-effective, environmentally friendly, and safe for biomedical use.
Collapse
Affiliation(s)
- Yuhe Shen
- State Key Laboratory of Chemical Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, P. R. China.
| | - Yulin Sun
- State Key Laboratory of Chemical Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, P. R. China.
| | - Yaoyu Liang
- State Key Laboratory of Chemical Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, P. R. China.
| | - Xiaojian Xu
- State Key Laboratory of Chemical Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, P. R. China.
| | - Rongxin Su
- State Key Laboratory of Chemical Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, P. R. China.
- Collaborative Innovation Centre of Chemical Science and Engineering (Tianjin), Tianjin 300072, P. R. China
- Tianjin Key Laboratory of Membrane Science and Desalination Technology, Tianjin University, Tianjin 300072, P. R. China
| | - Yuefei Wang
- State Key Laboratory of Chemical Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, P. R. China.
- Tianjin Key Laboratory of Membrane Science and Desalination Technology, Tianjin University, Tianjin 300072, P. R. China
| | - Wei Qi
- State Key Laboratory of Chemical Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, P. R. China.
- Collaborative Innovation Centre of Chemical Science and Engineering (Tianjin), Tianjin 300072, P. R. China
- Tianjin Key Laboratory of Membrane Science and Desalination Technology, Tianjin University, Tianjin 300072, P. R. China
| |
Collapse
|
2
|
Lee G, Jeong WH, Kim B, Jeon S, Smith AM, Seo J, Suzuki K, Kim JY, Lee H, Choi H, Chung DS, Choi J, Choi H, Lim SJ. Design and Synthesis of CdHgSe/HgS/CdZnS Core/Multi-Shell Quantum Dots Exhibiting High-Quantum-Yield Tissue-Penetrating Shortwave Infrared Luminescence. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2301161. [PMID: 37127870 PMCID: PMC11341011 DOI: 10.1002/smll.202301161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 04/18/2023] [Indexed: 05/03/2023]
Abstract
Cdx Hg1- x Se/HgS/Cdy Zn1- y S core/multi-shell quantum dots (QDs) exhibiting bright tissue-penetrating shortwave infrared (SWIR; 1000-1700 nm) photoluminescence (PL) are engineered. The new structure consists of a quasi-type-II Cdx Hg1- x Se/HgS core/inner shell domain creating luminescent bandgap tunable across SWIR window and a wide-bandgap Cdy Zn1- y S outer shell boosting the PL quantum yield (QY). This compositional sequence also facilitates uniform and coherent shell growth by minimizing interfacial lattice mismatches, resulting in high QYs in both organic (40-80%) and aqueous (20-70%) solvents with maximum QYs of 87 and 73%, respectively, which are comparable to those of brightest visible-to-near infrared QDs. Moreover, they maintain bright PL in a photocurable resin (QY 40%, peak wavelength ≈ 1300 nm), enabling the fabrication of SWIR-luminescent composites of diverse morphology and concentration. These composites are used to localize controlled amounts of SWIR QDs inside artificial (Intralipid) and porcine tissues and quantitatively evaluate the applicability as luminescent probes for deep-tissue imaging.
Collapse
Affiliation(s)
- Gyudong Lee
- Department of Energy Science and Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), 333 Techno Jungang Daero, Hyeonpung-Eup, Dalseong-Gun, Daegu, 42988, Republic of Korea
- Division of Nanotechnology, DGIST, 333 Techno Jungang Daero, Hyeonpung-Eup, Dalseong-Gun, Daegu, 42988, Republic of Korea
| | - Woo Hyeon Jeong
- Division of Nanotechnology, DGIST, 333 Techno Jungang Daero, Hyeonpung-Eup, Dalseong-Gun, Daegu, 42988, Republic of Korea
- Department of Chemistry and Research Institute for Natural Science, Hanyang University, 222 Wangsimni-ro, Seongdong-gu, Seoul, 04763, Republic of Korea
| | - Beomjoo Kim
- Department of Robotics Engineering, DGIST, 333 Techno Jungang Daero, Hyeonpung-Eup, Dalseong-Gun, Daegu, 42988, Republic of Korea
- DGIST-ETH Microrobotics Research Center, DGIST, 333 Techno Jungang Daero, Hyeonpung-Eup, Dalseong-Gun, Daegu, 42988, Republic of Korea
| | - Sungwoong Jeon
- DGIST-ETH Microrobotics Research Center, DGIST, 333 Techno Jungang Daero, Hyeonpung-Eup, Dalseong-Gun, Daegu, 42988, Republic of Korea
- IMsystem Corp., DGIST, 333 Techno Jungang Daero, Hyeonpung-Eup, Dalseong-Gun, Daegu, 42988, Republic of Korea
| | - Andrew M Smith
- Department of Bioengineering, University of Illinois Urbana-Champaign (UIUC), Urbana, IL, 61801, USA
- Department of Materials Science and Engineering, UIUC, Urbana, IL, 61801, USA
- Cancer Center at Illinois, UIUC, Urbana, IL, 61801, USA
- Carle Illinois College of Medicine, UIUC, Urbana, IL, 61801, USA
| | - Jongcheol Seo
- Department of Chemistry, POSTECH, 77 Cheongam-Ro, Nam-Gu, Pohang, Gyeongsangbuk-Do, 37673, Republic of Korea
| | - Kengo Suzuki
- Applied Spectroscopy System Department, Hamamatsu Photonics K.K., 812 Joko-Cho, Higashi-Ku, Hamamatsu City, 431-3196, Japan
| | - Jin-Young Kim
- DGIST-ETH Microrobotics Research Center, DGIST, 333 Techno Jungang Daero, Hyeonpung-Eup, Dalseong-Gun, Daegu, 42988, Republic of Korea
- Division of Biotechnology, DGIST, 333 Techno Jungang Daero, Hyeonpung-Eup, Dalseong-Gun, Daegu, 42988, Republic of Korea
| | - Hyunki Lee
- DGIST-ETH Microrobotics Research Center, DGIST, 333 Techno Jungang Daero, Hyeonpung-Eup, Dalseong-Gun, Daegu, 42988, Republic of Korea
- Division of Intelligent Robot, DGIST, 333 Techno Jungang Daero, Hyeonpung-Eup, Dalseong-Gun, Daegu, 42988, Republic of Korea
| | - Hongsoo Choi
- Department of Robotics Engineering, DGIST, 333 Techno Jungang Daero, Hyeonpung-Eup, Dalseong-Gun, Daegu, 42988, Republic of Korea
- DGIST-ETH Microrobotics Research Center, DGIST, 333 Techno Jungang Daero, Hyeonpung-Eup, Dalseong-Gun, Daegu, 42988, Republic of Korea
| | - Dae Sung Chung
- Department of Chemical Engineering, POSTECH, 77 Cheongam-Ro, Nam-Gu, Pohang, Gyeongsangbuk-Do, 37673, Republic of Korea
| | - Jongmin Choi
- Department of Energy Science and Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), 333 Techno Jungang Daero, Hyeonpung-Eup, Dalseong-Gun, Daegu, 42988, Republic of Korea
| | - Hyosung Choi
- Department of Chemistry and Research Institute for Natural Science, Hanyang University, 222 Wangsimni-ro, Seongdong-gu, Seoul, 04763, Republic of Korea
| | - Sung Jun Lim
- Division of Nanotechnology, DGIST, 333 Techno Jungang Daero, Hyeonpung-Eup, Dalseong-Gun, Daegu, 42988, Republic of Korea
| |
Collapse
|
3
|
Al-Salihi M, Chen Z, Samanta S, Elazab A, Yi R, Wang S, Lin F, Qu J, Liu L. Improving the performance of rapid lifetime determination for wide-field time-gated imaging in live cells. OPTICS EXPRESS 2022; 30:30760-30778. [PMID: 36242174 DOI: 10.1364/oe.454958] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Accepted: 07/08/2022] [Indexed: 06/16/2023]
Abstract
In biological research, rapid wide-field fluorescence lifetime imaging has become an important imaging tool. However, the biological samples with weak fluorescence signals and lower sensitivity often suffer from very low precision in lifetime determinations which restricts its widespread utilization in many bioimaging applications. To address this issue, a method is presented in this paper to substantially enhance the precision of rapid lifetime determination (RLD). It expedites the discrimination of fluorescence lifetimes, even for the weak signals coming from the cells, stained with long-lived biocompatible AIS/ZnS QDs. The proposed method works in two phases. The first phase deals with the systematic noise analysis based on the signal and contrast of the images in a time-gated imaging system, wherein acquiring the high-quality imaging data through optimization of hardware parameters improves the overall system performance. In the second phase, the chosen images are treated using total variation denoising method combined with the Max/Min filtering method for extracting the region of interest to reconstruct the intensity images for RLD. We performed several experiments on live cells to demonstrate the improvements in imaging performance by the systematic optimizations and data treatment. Obtained results demonstrated a great enhancement in signal-to-noise and contrast-to-noise ratios beside witnessing an obvious improvement in RLD for weak signals. This approach can be used not only to improve the quality of time-gated imaging data but also for efficient fluorescence lifetime imaging of live biological samples without compromising imaging speed and light exposure.
Collapse
|
4
|
Jeong S, Jung Y, Bok S, Ryu YM, Lee S, Kim YE, Song J, Kim M, Kim SY, Ahn GO, Kim S. Multiplexed In Vivo Imaging Using Size-Controlled Quantum Dots in the Second Near-Infrared Window. Adv Healthc Mater 2018; 7:e1800695. [PMID: 30450820 DOI: 10.1002/adhm.201800695] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2018] [Revised: 10/20/2018] [Indexed: 11/07/2022]
Abstract
PbS/CdS core/shell quantum dots (QDs) that emit at the second near-infrared (NIR-II, 1000-1700 nm) window are synthesized. The PbS seed size and CdS shell thicknesses are carefully controlled to produce bright and narrow fluorescence that are suitable for multiplexing. A polymer encapsulation yields polymer-encapsulated NIR-II QDs (PQDs), which provides the QDs with long-term fluorescence stability over a week in biological media. Exploiting the simple bioconjugation capability of PQDs, folic acids are conjugated to PQDs that can efficiently label folate receptor overexpressing cell lines. The PQDs afford multiplexed and nearly real-time longitudinal whole-body in vivo imaging. Two NIR-II QD probes are prepared: folic acid-conjugated PQDs (FA-PQDs) emitting at 1280 nm and unconjugated PQDs emitting at 1080 nm. The two PQDs are engineered to have compact and similar hydrodynamic sizes. A mixture of the folic acid-conjugated PQD and unconjugated PQDs is injected intravenously into a tumor-xenografted mouse, and the signals from them are monitored. This NIR-II whole-body imaging with the two PQDs provides precise evaluation of the active ligand-assisted tumor-targeting capability of the FA-PQD probe because the hydrodynamic size control of the two PQDs effectively eliminates effects from the size-dependent accumulations by permeations and retentions in tumors.
Collapse
Affiliation(s)
- Sanghwa Jeong
- Department of Chemistry; Pohang University of Science and Technology (POSTECH); 77 Cheongam-Ro, Nam-Gu Pohang Gyeongbuk 37673 Republic of Korea
| | - Yebin Jung
- Department of Chemistry; Pohang University of Science and Technology (POSTECH); 77 Cheongam-Ro, Nam-Gu Pohang Gyeongbuk 37673 Republic of Korea
| | - Seoyeon Bok
- Division of Integrative Biosciences and Biotechnology; POSTECH; 77 Cheongam-Ro, Nam-Gu Pohang Gyeongbuk 37673 Republic of Korea
| | - Yeon-Mi Ryu
- Asan Institute for Life Sciences; Asan Medical Center; 88 Olympic-ro, 43-gil Songpa-gu Seoul 05505 Republic of Korea
| | - Sumin Lee
- School of Interdisciplinary Bioscience and Bioengineering; POSTECH; 77 Cheongam-Ro, Nam-Gu Pohang Gyeongbuk 37673 Republic of Korea
| | - Young-Eun Kim
- Division of Integrative Biosciences and Biotechnology; POSTECH; 77 Cheongam-Ro, Nam-Gu Pohang Gyeongbuk 37673 Republic of Korea
| | - Jaejung Song
- School of Interdisciplinary Bioscience and Bioengineering; POSTECH; 77 Cheongam-Ro, Nam-Gu Pohang Gyeongbuk 37673 Republic of Korea
| | - Miyeon Kim
- Asan Institute for Life Sciences; Asan Medical Center; 88 Olympic-ro, 43-gil Songpa-gu Seoul 05505 Republic of Korea
| | - Sang-Yeob Kim
- Asan Institute for Life Sciences; Asan Medical Center; 88 Olympic-ro, 43-gil Songpa-gu Seoul 05505 Republic of Korea
- Department of Convergence Medicine; University of Ulsan College of Medicine; 88 Olympic-ro, 43-gil Songpa-gu Seoul 05505 Republic of Korea
| | - G-One Ahn
- Division of Integrative Biosciences and Biotechnology; POSTECH; 77 Cheongam-Ro, Nam-Gu Pohang Gyeongbuk 37673 Republic of Korea
| | - Sungjee Kim
- Department of Chemistry; Pohang University of Science and Technology (POSTECH); 77 Cheongam-Ro, Nam-Gu Pohang Gyeongbuk 37673 Republic of Korea
- School of Interdisciplinary Bioscience and Bioengineering; POSTECH; 77 Cheongam-Ro, Nam-Gu Pohang Gyeongbuk 37673 Republic of Korea
| |
Collapse
|
5
|
McHugh KJ, Jing L, Behrens AM, Jayawardena S, Tang W, Gao M, Langer R, Jaklenec A. Biocompatible Semiconductor Quantum Dots as Cancer Imaging Agents. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2018; 30:e1706356. [PMID: 29468747 DOI: 10.1002/adma.201706356] [Citation(s) in RCA: 167] [Impact Index Per Article: 23.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2017] [Revised: 11/26/2017] [Indexed: 05/20/2023]
Abstract
Approximately 1.7 million new cases of cancer will be diagnosed this year in the United States leading to 600 000 deaths. Patient survival rates are highly correlated with the stage of cancer diagnosis, with localized and regional remission rates that are much higher than for metastatic cancer. The current standard of care for many solid tumors includes imaging and biopsy with histological assessment. In many cases, after tomographical imaging modalities have identified abnormal morphology consistent with cancer, surgery is performed to remove the primary tumor and evaluate the surrounding lymph nodes. Accurate identification of tumor margins and staging are critical for selecting optimal treatments to minimize recurrence. Visible, fluorescent, and radiolabeled small molecules have been used as contrast agents to improve detection during real-time intraoperative imaging. Unfortunately, current dyes lack the tissue specificity, stability, and signal penetration needed for optimal performance. Quantum dots (QDs) represent an exciting class of fluorescent probes for optical imaging with tunable optical properties, high stability, and the ability to target tumors or lymph nodes based on surface functionalization. Here, state-of-the-art biocompatible QDs are compared with current Food and Drug Administration approved fluorophores used in cancer imaging and a perspective on the pathway to clinical translation is provided.
Collapse
Affiliation(s)
- Kevin J McHugh
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA, 02139, USA
| | - Lihong Jing
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA, 02139, USA
- Institute of Chemistry, Chinese Academy of Sciences, Bei Yi Jie 2, Zhong Guan Cun, Beijing, 100190, China
| | - Adam M Behrens
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA, 02139, USA
| | - Surangi Jayawardena
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA, 02139, USA
| | - Wen Tang
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA, 02139, USA
| | - Mingyuan Gao
- Institute of Chemistry, Chinese Academy of Sciences, Bei Yi Jie 2, Zhong Guan Cun, Beijing, 100190, China
| | - Robert Langer
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA, 02139, USA
| | - Ana Jaklenec
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA, 02139, USA
| |
Collapse
|
6
|
Early tumor detection afforded by in vivo imaging of near-infrared II fluorescence. Biomaterials 2017; 134:202-215. [DOI: 10.1016/j.biomaterials.2017.04.046] [Citation(s) in RCA: 82] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2016] [Revised: 04/24/2017] [Accepted: 04/24/2017] [Indexed: 01/19/2023]
|
7
|
Jeong S, Song J, Lee W, Ryu YM, Jung Y, Kim SY, Kim K, Hong SC, Myung SJ, Kim S. Cancer-Microenvironment-Sensitive Activatable Quantum Dot Probe in the Second Near-Infrared Window. NANO LETTERS 2017; 17:1378-1386. [PMID: 28125238 DOI: 10.1021/acs.nanolett.6b04261] [Citation(s) in RCA: 66] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Recent technological advances have expanded fluorescence (FL) imaging into the second near-infrared region (NIR-II; wavelength = 1000-1700 nm), providing high spatial resolution through deep tissues. However, bright and compact fluorophores are rare in this region, and sophisticated control over NIR-II probes has not been fully achieved yet. Herein, we report an enzyme-activatable NIR-II probe that exhibits FL upon matrix metalloprotease activity in tumor microenvironment. Bright and stable PbS/CdS/ZnS core/shell/shell quantum dots (QDs) were synthesized as a model NIR-II fluorophore, and activatable modulators were attached to exploit photoexcited electron transfer (PET) quenching. The quasi type-II QD band alignment allowed rapid and effective FL modulations with the compact surface ligand modulator that contains methylene blue PET quencher. The modulator was optimized to afford full enzyme accessibility and high activation signal surge upon the enzyme activity. Using a colon cancer mouse model, the probe demonstrated selective FL activation at tumor sites with 3-fold signal enhancement in 10 min. Optical phantom experiments confirmed the advantages of the NIR-II probe over conventional dyes in the first near-infrared region.
Collapse
Affiliation(s)
| | | | | | - Yeon Mi Ryu
- Asan Institute for Life Sciences, Asan Medical Center , 88 Olympic-ro, 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
| | | | - Sang-Yeob Kim
- Asan Institute for Life Sciences, Asan Medical Center , 88 Olympic-ro, 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
- Department of Convergence Medicine, University of Ulsan College of Medicine , 88 Olympic-ro, 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
| | - Kangwook Kim
- Department of Civil and Environmental Engineering, Korea Army Academy at Young-cheon , Yeongcheon-si, Gyeongsangbuk-do South Korea
| | | | - Seung Jae Myung
- Asan Institute for Life Sciences, Asan Medical Center , 88 Olympic-ro, 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
- Department of Convergence Medicine, University of Ulsan College of Medicine , 88 Olympic-ro, 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
- Department of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine , 88 Olympic-ro, 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
| | | |
Collapse
|
8
|
Medically translatable quantum dots for biosensing and imaging. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY C-PHOTOCHEMISTRY REVIEWS 2017. [DOI: 10.1016/j.jphotochemrev.2017.01.002] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
9
|
Zhang H, Salo D, Kim DM, Komarov S, Tai YC, Berezin MY. Penetration depth of photons in biological tissues from hyperspectral imaging in shortwave infrared in transmission and reflection geometries. JOURNAL OF BIOMEDICAL OPTICS 2016; 21:126006. [PMID: 27930773 PMCID: PMC5147011 DOI: 10.1117/1.jbo.21.12.126006] [Citation(s) in RCA: 71] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2016] [Accepted: 11/11/2016] [Indexed: 05/20/2023]
Abstract
Measurement of photon penetration in biological tissues is a central theme in optical imaging. A great number of endogenous tissue factors such as absorption, scattering, and anisotropy affect the path of photons in tissue, making it difficult to predict the penetration depth at different wavelengths. Traditional studies evaluating photon penetration at different wavelengths are focused on tissue spectroscopy that does not take into account the heterogeneity within the sample. This is especially critical in shortwave infrared where the individual vibration-based absorption properties of the tissue molecules are affected by nearby tissue components. We have explored the depth penetration in biological tissues from 900 to 1650 nm using Monte–Carlo simulation and a hyperspectral imaging system with Michelson spatial contrast as a metric of light penetration. Chromatic aberration-free hyperspectral images in transmission and reflection geometries were collected with a spectral resolution of 5.27 nm and a total acquisition time of 3 min. Relatively short recording time minimized artifacts from sample drying. Results from both transmission and reflection geometries consistently revealed that the highest spatial contrast in the wavelength range for deep tissue lies within 1300 to 1375 nm; however, in heavily pigmented tissue such as the liver, the range 1550 to 1600 nm is also prominent.
Collapse
Affiliation(s)
- Hairong Zhang
- Washington University School of Medicine, Department of Radiology, St. Louis, Missouri, United States
| | - Daniel Salo
- Washington University School of Medicine, Department of Radiology, St. Louis, Missouri, United States
| | - David M. Kim
- Washington University School of Medicine, Department of Radiology, St. Louis, Missouri, United States
| | - Sergey Komarov
- Washington University School of Medicine, Department of Radiology, St. Louis, Missouri, United States
| | - Yuan-Chuan Tai
- Washington University School of Medicine, Department of Radiology, St. Louis, Missouri, United States
| | - Mikhail Y. Berezin
- Washington University School of Medicine, Department of Radiology, St. Louis, Missouri, United States
- Address all correspondence to: Mikhail Y. Berezin, E-mail:
| |
Collapse
|