1
|
Kadarwati LV, Lin IH, Huang YS, Lee YY, Chen SC, Chung CL, Chen IJ, Wang JY, Yougbaré S, Cheng TM, Kuo TR. Exploring Label-Free Imaging Techniques with Copper Sulfide Microspheres for Observing Breast Cancer Cells. ACS OMEGA 2024; 9:37882-37890. [PMID: 39281899 PMCID: PMC11391449 DOI: 10.1021/acsomega.4c04154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Revised: 08/19/2024] [Accepted: 08/22/2024] [Indexed: 09/18/2024]
Abstract
A single breast cancer is a prevalent form of cancer, affecting over 2.3 million women worldwide, as reported by the World Health Organization. Recently, researchers have extensively explored the utilization of biomaterials in breast cancer theranostics. One notable biomaterial being investigated is various structures of copper sulfide (CuS). In this work, a microsphere (MS) structure composed of CuS was employed for label-free imaging of MCF-7 breast cancer cells and normal Vero cells, respectively. Various label-free imaging techniques, such as bright field, dark field, phase contrast (PC), and differential interference contrast (DIC), were employed to capture images of CuS MSs, cell, and intact CuS MSs within a cell. The study compared the outcomes of each imaging technique and determined that DIC imaging provided the highest resolution for cells incubated with CuS MSs. Furthermore, the combination of PC and DIC techniques proved to be effective for imaging breast cancer cells in conjunction with CuS MSs. This research underscores the potential of CuS MSs for label-free cell detection and emphasizes the significance of selecting appropriate imaging techniques to attain high-quality images in the field of cell observation.
Collapse
Affiliation(s)
- Lutvi Vitria Kadarwati
- Graduate Institute of Biomedical Optomechatronics, College of Biomedical Engineering, Taipei Medical University, Taipei 11031, Taiwan
| | - I-Hsin Lin
- School of Biomedical Engineering, College of Biomedical Engineering, Taipei Medical University, Taipei 11031, Taiwan
| | - Yu-Shan Huang
- Graduate Institute of Nanomedicine and Medical Engineering, College of Biomedical Engineering, Taipei Medical University, Taipei 11031, Taiwan
| | - Yu-Yang Lee
- Southport Corporation, New Taipei City 22175, Taiwan
| | | | | | - I-Jan Chen
- Southport Corporation, New Taipei City 22175, Taiwan
| | - Jia-Yeh Wang
- Southport Corporation, New Taipei City 22175, Taiwan
| | - Sibidou Yougbaré
- Institut de Recherche en Sciences de La Santé/Direction Régionale du Centre Ouest (IRSS/DRCO), Nanoro BP 218, 11, Burkina Faso
| | - Tsai-Mu Cheng
- Graduate Institute for Translational Medicine, College of Medical Science and Technology, Taipei Medical University, Taipei 11031, Taiwan
- Taipei Heart Institute, Taipei Medical University, Taipei 11031, Taiwan
- Cardiovascular Research Center, Taipei Medical University Hospital, Taipei Medical University, Taipei 11031, Taiwan
| | - Tsung-Rong Kuo
- Graduate Institute of Nanomedicine and Medical Engineering, College of Biomedical Engineering, Taipei Medical University, Taipei 11031, Taiwan
- International Ph.D. Program in Biomedical Engineering, College of Biomedical Engineering, Taipei Medical University, Taipei 11031, Taiwan
- Stanford Byers Center for Biodesign, Stanford University, Stanford, California 94305, United States
| |
Collapse
|
2
|
Guo X, Chang J, Chen W, Hu Y, Ma N, Zhang J. High-detection-efficiency stereo microscope system based on a mobile phone. APPLIED OPTICS 2023; 62:5236-5243. [PMID: 37707227 DOI: 10.1364/ao.489445] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Accepted: 05/30/2023] [Indexed: 09/15/2023]
Abstract
Most stereoscopic microscopes used for industrial component detection are large and have low detection efficiencies. The use of mobile phones as imaging systems (rather than conventional sensors) in industrial fields would make industrial testing more convenient. In this study, an external stereo microscope for mobile phones is designed. The proposed system can resolve details up to 0.01 mm with an 11 mm object field of view, -6.34× angular magnification, and quantitative 3D feature measurement. The combined system proposed in this paper is suitable for the microscopic observation of industrial components, with its low cost, high detection efficiency, and short installation steps.
Collapse
|
3
|
Wang R, Deutsch RJ, Sunassee ED, Crouch BT, Ramanujam N. Adaptive Design of Fluorescence Imaging Systems for Custom Resolution, Fields of View, and Geometries. BME FRONTIERS 2023; 4:0005. [PMID: 37849673 PMCID: PMC10521686 DOI: 10.34133/bmef.0005] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Accepted: 11/27/2022] [Indexed: 10/19/2023] Open
Abstract
Objective and Impact Statement: We developed a generalized computational approach to design uniform, high-intensity excitation light for low-cost, quantitative fluorescence imaging of in vitro, ex vivo, and in vivo samples with a single device. Introduction: Fluorescence imaging is a ubiquitous tool for biomedical applications. Researchers extensively modify existing systems for tissue imaging, increasing the time and effort needed for translational research and thick tissue imaging. These modifications are application-specific, requiring new designs to scale across sample types. Methods: We implemented a computational model to simulate light propagation from multiple sources. Using a global optimization algorithm and a custom cost function, we determined the spatial positioning of optical fibers to generate 2 illumination profiles. These results were implemented to image core needle biopsies, preclinical mammary tumors, or tumor-derived organoids. Samples were stained with molecular probes and imaged with uniform and nonuniform illumination. Results: Simulation results were faithfully translated to benchtop systems. We demonstrated that uniform illumination increased the reliability of intraimage analysis compared to nonuniform illumination and was concordant with traditional histological findings. The computational approach was used to optimize the illumination geometry for the purposes of imaging 3 different fluorophores through a mammary window chamber model. Illumination specifically designed for intravital tumor imaging generated higher image contrast compared to the case in which illumination originally optimized for biopsy images was used. Conclusion: We demonstrate the significance of using a computationally designed illumination for in vitro, ex vivo, and in vivo fluorescence imaging. Application-specific illumination increased the reliability of intraimage analysis and enhanced the local contrast of biological features. This approach is generalizable across light sources, biological applications, and detectors.
Collapse
Affiliation(s)
- Roujia Wang
- Department of Biomedical Engineering, Duke University, Durham, NC, USA
| | - Riley J. Deutsch
- Department of Biomedical Engineering, Duke University, Durham, NC, USA
| | | | - Brian T. Crouch
- Department of Biomedical Engineering, Duke University, Durham, NC, USA
| | - Nirmala Ramanujam
- Department of Biomedical Engineering, Duke University, Durham, NC, USA
- Department of Pharmacology and Cancer Biology, Duke University Medical Center, Durham, NC, USA
| |
Collapse
|
4
|
Meng Q, Li Y, Yu Y, Chu K, Smith ZJ. A Drop-in, Focus-Extending Phase Mask Simplifies Microscopic and Microfluidic Imaging Systems for Cost-Effective Point-of-Care Diagnostics. Anal Chem 2022; 94:11000-11007. [PMID: 35895976 DOI: 10.1021/acs.analchem.2c01421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Microscopic imaging and imaging flow cytometry have wide potential in point-of-care assays; however, their narrow depth of focus necessitates precise mechanical or fluidic focus control of a sample in order to acquire high-quality images that can be used for downstream analysis, increasing the cost and complexity of the imaging system. This complexity represents a barrier to miniaturization and translation of point-of-care assays based on microscopic imaging or imaging flow cytometry. To address this challenge, we present a simple drop-in phase mask with a physics-informed, circularly symmetric asphere phase profile that extends the depth of focus by >5-fold while largely preserving the image quality compared to other depth extending methods. We show that such a focus-extended system overcomes manufacturing tolerances in low-cost sample chambers, enlarges the useable field-of-view of low-cost objectives, and permits increased throughput and precision in flow imaging systems without the need for complex flow-focusing. As the image quality is preserved without the need for postacquisition image restoration, our solution is also highly appropriate for on-line applications such as cell sorting.
Collapse
Affiliation(s)
- Qi Meng
- Key Laboratory of Precision Scientific Instrumentation of Anhui Higher Education Institutes, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, Anhui 230027, China
| | - Yaning Li
- Key Laboratory of Precision Scientific Instrumentation of Anhui Higher Education Institutes, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, Anhui 230027, China
| | - Yajun Yu
- Key Laboratory of Precision Scientific Instrumentation of Anhui Higher Education Institutes, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, Anhui 230027, China
| | - Kaiqin Chu
- Suzhou Institute for Advanced Research, University of Science and Technology of China, Suzhou, Jiangsu 215123, China
| | - Zachary J Smith
- Key Laboratory of Precision Scientific Instrumentation of Anhui Higher Education Institutes, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, Anhui 230027, China
| |
Collapse
|
5
|
Katare P, Gorthi SS. Recent technical advances in whole slide imaging instrumentation. J Microsc 2021; 284:103-117. [PMID: 34254690 DOI: 10.1111/jmi.13049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2021] [Revised: 07/05/2021] [Accepted: 07/06/2021] [Indexed: 11/28/2022]
Abstract
Microscopic observation of biological specimen smears is the mainstay of diagnostic pathology, as defined by the Digital Pathology Association. Though automated systems for this are commercially available, their bulky size and high cost renders them unusable for remote areas. The research community is investing much effort towards building equivalent but portable, low-cost systems. An overview of such research is presented here, including a comparative analysis of recent reports. This paper also reviews recently reported systems for automated staining and smear formation, including microfluidic devices; and optical and computational automated microscopy systems including smartphone-based devices. Image pre-processing and analysis methods for automated diagnosis are also briefly discussed. It concludes with a set of foreseeable research directions that could lead to affordable, integrated and accurate whole slide imaging systems.
Collapse
Affiliation(s)
- Prateek Katare
- Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore, India
| | - Sai Siva Gorthi
- Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore, India
| |
Collapse
|
6
|
Hunt B, Ruiz AJ, Pogue BW. Smartphone-based imaging systems for medical applications: a critical review. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-200421VR. [PMID: 33860648 PMCID: PMC8047775 DOI: 10.1117/1.jbo.26.4.040902] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Accepted: 03/29/2021] [Indexed: 05/15/2023]
Abstract
SIGNIFICANCE Smartphones come with an enormous array of functionality and are being more widely utilized with specialized attachments in a range of healthcare applications. A review of key developments and uses, with an assessment of strengths/limitations in various clinical workflows, was completed. AIM Our review studies how smartphone-based imaging (SBI) systems are designed and tested for specialized applications in medicine and healthcare. An evaluation of current research studies is used to provide guidelines for improving the impact of these research advances. APPROACH First, the established and emerging smartphone capabilities that can be leveraged for biomedical imaging are detailed. Then, methods and materials for fabrication of optical, mechanical, and electrical interface components are summarized. Recent systems were categorized into four groups based on their intended application and clinical workflow: ex vivo diagnostic, in vivo diagnostic, monitoring, and treatment guidance. Lastly, strengths and limitations of current SBI systems within these various applications are discussed. RESULTS The native smartphone capabilities for biomedical imaging applications include cameras, touchscreens, networking, computation, 3D sensing, audio, and motion, in addition to commercial wearable peripheral devices. Through user-centered design of custom hardware and software interfaces, these capabilities have the potential to enable portable, easy-to-use, point-of-care biomedical imaging systems. However, due to barriers in programming of custom software and on-board image analysis pipelines, many research prototypes fail to achieve a prospective clinical evaluation as intended. Effective clinical use cases appear to be those in which handheld, noninvasive image guidance is needed and accommodated by the clinical workflow. Handheld systems for in vivo, multispectral, and quantitative fluorescence imaging are a promising development for diagnostic and treatment guidance applications. CONCLUSIONS A holistic assessment of SBI systems must include interpretation of their value for intended clinical settings and how their implementations enable better workflow. A set of six guidelines are proposed to evaluate appropriateness of smartphone utilization in terms of clinical context, completeness, compactness, connectivity, cost, and claims. Ongoing work should prioritize realistic clinical assessments with quantitative and qualitative comparison to non-smartphone systems to clearly demonstrate the value of smartphone-based systems. Improved hardware design to accommodate the rapidly changing smartphone ecosystem, creation of open-source image acquisition and analysis pipelines, and adoption of robust calibration techniques to address phone-to-phone variability are three high priority areas to move SBI research forward.
Collapse
Affiliation(s)
- Brady Hunt
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
- Address all correspondence to Brady Hunt,
| | - Alberto J. Ruiz
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
| | - Brian W. Pogue
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
| |
Collapse
|
7
|
Paul R, Zhou Y, Nikfar M, Razizadeh M, Liu Y. Quantitative absorption imaging of red blood cells to determine physical and mechanical properties. RSC Adv 2020; 10:38923-38936. [PMID: 33240491 PMCID: PMC7685304 DOI: 10.1039/d0ra05421f] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2020] [Accepted: 09/28/2020] [Indexed: 12/18/2022] Open
Abstract
Red blood cells or erythrocytes, constituting 40 to 45 percent of the total volume of human blood are vesicles filled with hemoglobin with a fluid-like lipid bilayer membrane connected to a 2D spectrin network. The shape, volume, hemoglobin mass, and membrane stiffness of RBCs are important characteristics that influence their ability to circulate through the body and transport oxygen to tissues. In this study, we show that a simple two-LED set up in conjunction with standard microscope imaging can accurately determine the physical and mechanical properties of single RBCs. The Beer-Lambert law and undulatory motion dynamics of the membrane have been used to measure the total volume, hemoglobin mass, membrane tension coefficient, and bending modulus of RBCs. We also show that this method is sensitive enough to distinguish between the mechanical properties of RBCs during morphological changes from a typical discocyte to echinocytes and spherocytes. Measured values of the tension coefficient and bending modulus are 1.27 × 10-6 J m-2 and 7.09 × 10-2 J for discocytes, 4.80 × 10-6 J m-2 and 7.70 × 10-20 J for echinocytes, and 9.85 × 10-6 J m-2 and 9.69 × 10-20 J for spherocytes, respectively. This quantitative light absorption imaging reduces the complexity related to the quantitative imaging of the biophysical and mechanical properties of a single RBC that may lead to enhanced yet simplified point of care devices for analyzing blood cells.
Collapse
Affiliation(s)
- Ratul Paul
- Department of Mechanical Engineering and Mechanics, Lehigh UniversityBethlehemPennsylvania 18015USA
| | - Yuyuan Zhou
- Department of Bioengineering, Lehigh UniversityBethlehemPennsylvania 18015USA
| | - Mehdi Nikfar
- Department of Mechanical Engineering and Mechanics, Lehigh UniversityBethlehemPennsylvania 18015USA
| | - Meghdad Razizadeh
- Department of Mechanical Engineering and Mechanics, Lehigh UniversityBethlehemPennsylvania 18015USA
| | - Yaling Liu
- Department of Mechanical Engineering and Mechanics, Lehigh UniversityBethlehemPennsylvania 18015USA
- Department of Bioengineering, Lehigh UniversityBethlehemPennsylvania 18015USA
| |
Collapse
|
8
|
Long J, Parker HE, Ehrlich K, Tanner MG, Dhaliwal K, Mills B. Frugal filtering optical lenses for point-of-care diagnostics. BIOMEDICAL OPTICS EXPRESS 2020; 11:1864-1875. [PMID: 32341853 PMCID: PMC7173883 DOI: 10.1364/boe.381014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2019] [Revised: 02/13/2020] [Accepted: 02/17/2020] [Indexed: 05/11/2023]
Abstract
Infectious diseases are the leading cause of morbidity and mortality in low and middle income countries (LMICs). Rapid diagnosis of infections in LMICs presents many challenges, especially in rural areas where access to health care, including diagnostics, is poor. Microscopy is one of the most commonly used platforms to diagnose bacterial infections on clinical samples. Fluorescence microscopy has high sensitivity and specificity but to date is mostly performed within a laboratory setting due to the high-cost, low portability and highly specialist nature of equipment. Point-of-care diagnostics could offer a solution to the challenge of infection diagnosis in LMICs. In this paper we present frugal, easy to manufacture, doped polydimethylsiloxane filtering optical lenses that can be integrated into smartphone microscopes for immediate detection of fluorescently labelled bacteria. This provides a breakthrough technology platform for point-of-care diagnostics.
Collapse
Affiliation(s)
- Joanna Long
- EPSRC Proteus IRC Hub in Optical Molecular Sensing and Imaging, Centre for Inflammation Research, Queen's Medical Research Institute, University of Edinburgh, Edinburgh, EH16 4TJ, UK
| | - Helen E. Parker
- EPSRC Proteus IRC Hub in Optical Molecular Sensing and Imaging, Centre for Inflammation Research, Queen's Medical Research Institute, University of Edinburgh, Edinburgh, EH16 4TJ, UK
- Department of Applied Physics, Royal Institute of Technology, Stockholm, Sweden
| | - Katjana Ehrlich
- EPSRC Proteus IRC Hub in Optical Molecular Sensing and Imaging, Centre for Inflammation Research, Queen's Medical Research Institute, University of Edinburgh, Edinburgh, EH16 4TJ, UK
| | - Michael G. Tanner
- EPSRC Proteus IRC Hub in Optical Molecular Sensing and Imaging, Centre for Inflammation Research, Queen's Medical Research Institute, University of Edinburgh, Edinburgh, EH16 4TJ, UK
- Scottish Universities Physics Alliance (SUPA), Institute of Photonics and Quantum Science (IPAQS), Heriot-Watt University, Edinburgh, EH14 4AS, UK
| | - Kevin Dhaliwal
- EPSRC Proteus IRC Hub in Optical Molecular Sensing and Imaging, Centre for Inflammation Research, Queen's Medical Research Institute, University of Edinburgh, Edinburgh, EH16 4TJ, UK
| | - Bethany Mills
- EPSRC Proteus IRC Hub in Optical Molecular Sensing and Imaging, Centre for Inflammation Research, Queen's Medical Research Institute, University of Edinburgh, Edinburgh, EH16 4TJ, UK
| |
Collapse
|