Zhang Y, Liu Y, Zhu G, Wang Q, Ni J, Liu L, Zhang J, Zhang J, Li Z, Wang X, Huang Y, Dong M, Zhang Y, Wang Y. Noninvasive detection of diabetes mellitus based on skin fluorescence and diffuse reflectance spectroscopy. JOURNAL OF BIOPHOTONICS 2024; 17:e202300098. [PMID: 37698142 DOI: 10.1002/jbio.202300098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 08/31/2023] [Accepted: 09/04/2023] [Indexed: 09/13/2023]
Abstract
There is an urgent need for a mass population screening tool for diabetes. Skin tissue contains a large number of endogenous fluorophores and physiological parameter markers related to diabetes. We built an excitation-emission spectrum measurement system with the excited light sources of 365, 395, 415, 430, and 455 nm to extract skin characteristics. The modeling experiment was carried out to design and verify the accuracy of the recovery of tissue intrinsic discrete three-dimensional fluorescence spectrum. Blood oxygen modeling experiment results indicated the accuracy of the physiological parameter extraction algorithm based on the diffuse reflectance spectrum. A community population cohort study was carried out. The tissue-reduced scattering coefficient and scattering power of the diabetes were significantly higher than normal control groups. The Gaussian multi-peak fitting was performed on each excitation-emission spectrum of the subject. A total of 63 fluorescence features containing information such as Gaussian spectral curve intensity, central wavelength position, and variance were obtained from each person. Logistic regression was used to construct the diabetes screening model. The results showed that the area under the receiver operating characteristic curve of the model for predicting diabetes was 0.816, indicating a high diagnostic value. As a rapid and non-invasive detection method, it is expected to have high clinical value.
Collapse
Affiliation(s)
- Yuanzhi Zhang
- Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Provincial Engineering Laboratory for Medical Optical Diagnosis Treatment Technology and Instrument, Hefei, China
| | - Yong Liu
- Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Provincial Engineering Laboratory for Medical Optical Diagnosis Treatment Technology and Instrument, Hefei, China
| | - Guoqing Zhu
- Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Provincial Engineering Laboratory for Medical Optical Diagnosis Treatment Technology and Instrument, Hefei, China
| | - Quanfu Wang
- Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Provincial Engineering Laboratory for Medical Optical Diagnosis Treatment Technology and Instrument, Hefei, China
| | - Jingshu Ni
- Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Provincial Engineering Laboratory for Medical Optical Diagnosis Treatment Technology and Instrument, Hefei, China
| | - Lin Liu
- Endocrinology Department, Peking University First Hospital, Beijing, China
| | - Jian Zhang
- Endocrinology Department, Peking University First Hospital, Beijing, China
| | - Junqing Zhang
- Endocrinology Department, Peking University First Hospital, Beijing, China
| | - Zhongsheng Li
- Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Provincial Engineering Laboratory for Medical Optical Diagnosis Treatment Technology and Instrument, Hefei, China
| | - Xia Wang
- Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Provincial Engineering Laboratory for Medical Optical Diagnosis Treatment Technology and Instrument, Hefei, China
| | - Yao Huang
- Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Provincial Engineering Laboratory for Medical Optical Diagnosis Treatment Technology and Instrument, Hefei, China
| | - Meili Dong
- Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Provincial Engineering Laboratory for Medical Optical Diagnosis Treatment Technology and Instrument, Hefei, China
| | - Yang Zhang
- Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Provincial Engineering Laboratory for Medical Optical Diagnosis Treatment Technology and Instrument, Hefei, China
| | - Yikun Wang
- Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Provincial Engineering Laboratory for Medical Optical Diagnosis Treatment Technology and Instrument, Hefei, China
| |
Collapse
|
2
|
Hasan MZ, Saha PS, Korfhage MO, Zhu C. Non-contact optical spectroscopy for tumor-sensitive diffuse reflectance and fluorescence measurements on murine subcutaneous tissue models: Monte Carlo modeling and experimental validations. BIOMEDICAL OPTICS EXPRESS 2023; 14:5418-5439. [PMID: 37854556 PMCID: PMC10581788 DOI: 10.1364/boe.502778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 09/12/2023] [Accepted: 09/16/2023] [Indexed: 10/20/2023]
Abstract
Fiber-optic probes are commonly used in biomedical optical spectroscopy platforms for light delivery and collection. At the same time, it was reported that the inconsistent probe-sample contact could induce significant distortions in measured optical signals, which consequently cause large analysis errors. To address this challenge, non-contact optical spectroscopy has been explored for tissue characterizations. However, existing non-contact optical spectroscopy platforms primarily focused on diffuse reflectance measurements and may still use a fiber probe in which the probe was imaged onto the tissue surface using a lens, which serves as a non-contact probe for the measurements. Here, we report a fiber-probe-free, dark-field-based, non-contact optical spectroscopy for both diffuse reflectance and fluorescence measurements on turbid medium and tissues. To optimize the system design, we developed a novel Monte Carlo method to simulate such a non-contact setup for both diffuse reflectance and fluorescence measurements on murine subcutaneous tissue models with a spherical tumor-like target. We performed Monte Carlo simulations to identify the most tumor-sensitive configurations, from which we found that both the depth of the light focal point in tissue and the lens numerical aperture would dramatically affect the system's tumor detection sensitivity. We then conducted tissue-mimicking phantom studies to solidify these findings. Our reported Monte Carlo technique can be a useful computational tool for designing non-contact optical spectroscopy systems. Our non-contact optical setup and experimental findings will potentially offer a new approach for sensitive optical monitoring of tumor physiology in biological models using a non-contact optical spectroscopy platform to advance cancer research.
Collapse
Affiliation(s)
- Md Zahid Hasan
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Pranto Soumik Saha
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Madison O. Korfhage
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Caigang Zhu
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| |
Collapse
|
3
|
Yan J, Lima Goncalves CF, Korfhage MO, Hasan MZ, Fan TWM, Wang X, Zhu C. Portable optical spectroscopic assay for non-destructive measurement of key metabolic parameters on in vitro cancer cells and organotypic fresh tumor slices. BIOMEDICAL OPTICS EXPRESS 2023; 14:4065-4079. [PMID: 37799678 PMCID: PMC10549737 DOI: 10.1364/boe.497127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 07/04/2023] [Accepted: 07/05/2023] [Indexed: 10/07/2023]
Abstract
To enable non-destructive metabolic characterizations on in vitro cancer cells and organotypic tumor models for therapeutic studies in an easy-to-access way, we report a highly portable optical spectroscopic assay for simultaneous measurement of glucose uptake and mitochondrial function on various cancer models with high sensitivity. Well-established breast cancer cell lines (MCF-7 and MDA-MB-231) were used to validate the optical spectroscopic assay for metabolic characterizations, while fresh tumor samples harvested from both animals and human cancer patients were used to test the feasibility of our optical metabolic assay for non-destructive measurement of key metabolic parameters on organotypic tumor slices. Our optical metabolic assay captured that MCF-7 cells had higher mitochondrial metabolism, but lower glucose uptake compared to the MDA-MB-231 cells, which is consistent with our microscopy imaging and flow cytometry data, as well as the published Seahorse Assay data. Moreover, we demonstrated that our optical assay could non-destructively measure both glucose uptake and mitochondrial metabolism on the same cancer cell samples at one time, which remains challenging by existing metabolic tools. Our pilot tests on thin fresh tumor slices showed that our optical assay captured increased metabolic activities in tumors compared to normal tissues. Our non-destructive optical metabolic assay provides a cost-effective way for future longitudinal therapeutic studies using patient-derived organotypic fresh tumor slices through the lens of tumor energetics, which will significantly advance translational cancer research.
Collapse
Affiliation(s)
- Jing Yan
- Department of Biomedical Engineering,
University of Kentucky, Lexington, KY 40506, USA
| | | | - Madison O. Korfhage
- Department of Biomedical Engineering,
University of Kentucky, Lexington, KY 40506, USA
| | - Md Zahid Hasan
- Department of Biomedical Engineering,
University of Kentucky, Lexington, KY 40506, USA
| | - Teresa W.-M. Fan
- Center for Environmental and Systems Biochemistry, University of Kentucky, Lexington, KY 40536, USA
- Markey Cancer Center, University of Kentucky, Lexington, KY 40536, USA
- Department of Toxicology and Cancer Biology, University of Kentucky, Lexington, KY 40536, USA
| | - Xiaoqin Wang
- Department of Radiology, University of Kentucky, Lexington, KY 40536, USA
| | - Caigang Zhu
- Department of Biomedical Engineering,
University of Kentucky, Lexington, KY 40506, USA
| |
Collapse
|
4
|
Hasan MZ, Yan J, Yi Z, Korfhage MO, Tong S, Zhu C. Low-cost compact optical spectroscopy and novel spectroscopic algorithm for point-of-care real-time monitoring of nanoparticle delivery in biological tissue models. IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS : A PUBLICATION OF THE IEEE LASERS AND ELECTRO-OPTICS SOCIETY 2023; 29:7100208. [PMID: 36341280 PMCID: PMC9635618 DOI: 10.1109/jstqe.2022.3205862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Objective Real-time monitoring of nanoparticle delivery in biological models is essential to optimize nanoparticle-mediated therapies. However, few techniques are available for convenient real-time monitoring of nanoparticle concentrations in tissue samples. This work reported novel optical spectroscopic approaches for low-cost point-of-care real-time quantification of nanoparticle concentrations in biological tissue samples. Methods Fiber probe measured diffuse reflectance can be described with a simple analytical model by introducing an explicit dependence on the reduced scattering coefficient. Relying on this, the changes on the inverse of diffuse reflectance are proportional to absorption change when the scattering perturbation is negligible. We developed this model with proper wavelength pairs and implemented it with both a standard optical spectroscopy platform and a low-cost compact spectroscopy device for near real-time quantification of nanoparticle concentrations in biological tissue models. Results Both tissue-mimicking phantom and ex vivo tissue sample studies showed that our optical spectroscopic techniques could quantify nanoparticle concentrations in near real-time with high accuracies (less than 5% error) using only a pair of narrow wavelengths (530 nm and 630 nm). Conclusion Novel low-cost point-of-care optical spectroscopic techniques were demonstrated for rapid accurate quantification of nanoparticle concentrations in tissue-mimicking medium and ex vivo tissue samples using optical signals measured at a pair of narrow wavelengths. Significance Our methods will potentially facilitate real-time monitoring of nanoparticle delivery in biological models using low-cost point-of-care optical spectroscopy platforms, which will significantly advance nanomedicine in cancer research.
Collapse
Affiliation(s)
- Md Zahid Hasan
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Jing Yan
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Zhongchao Yi
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Madison O Korfhage
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Sheng Tong
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Caigang Zhu
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| |
Collapse
|
5
|
Roccabruna JR, Bridger KG, Baran TM. Fluorescence and diffuse reflectance provide similar accuracy in recovering fluorophore concentration at short source-detector separations. JOURNAL OF MODERN OPTICS 2022; 69:699-704. [PMID: 36035874 PMCID: PMC9401209 DOI: 10.1080/09500340.2022.2074159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Quantitative fluorescence spectroscopy requires corresponding reflectance measurements to correct for tissue absorption and scattering. However, it is unclear whether fluorescence adds value beyond the diffuse reflectance measurements necessary for correction. The goal of this study was to compare the accuracy of fluorescence and diffuse reflectance spectroscopy in recovering the concentration of a high-extinction fluorophore, methylene blue (MB), using a compact fiber-optic probe. Fluorescence and diffuse reflectance measurements of tissue simulating phantoms were made using a fiber-optic probe with source-detector separations of 288-1300 μm. Average error in recovered fluorophore concentration was 20.4% for fluorescence and 15.0% for reflectance, though this difference was not significant (p=0.77). Both methods returned concentrations that were similar to known MB concentrations (p≥0.79 in both cases). Fluorescence quantification of the concentration of a high extinction fluorophore did not significantly improve accuracy relative to diffuse reflectance. Investigators should consider whether fluorescence measurements are necessary for a given application.
Collapse
Affiliation(s)
- Jacob R. Roccabruna
- Department of Biomedical Engineering, University of Rochester, Rochester, NY, United States of America
| | - Karina G. Bridger
- Department of Biomedical Engineering, University of Rochester, Rochester, NY, United States of America
| | - Timothy M. Baran
- Department of Biomedical Engineering, University of Rochester, Rochester, NY, United States of America
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY, United States of America
- Corresponding author: Timothy M. Baran,
| |
Collapse
|