1
|
Rijken J, Crowe S, Trapp J, Kairn T. A review of stereotactic body radiotherapy for the spine. Phys Eng Sci Med 2020; 43:799-824. [DOI: 10.1007/s13246-020-00889-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2019] [Accepted: 06/11/2020] [Indexed: 12/11/2022]
|
2
|
Aoyama T, Shimizu H, Isomura T, Kitagawa T, Tanaka K, Kodaira T. [Development of an In-house Couch Model to Improve Dose Attenuation Correction Accuracy for a Couch with Different Thickness in the Superior-inferior Direction]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2019; 75:1125-1134. [PMID: 31631105 DOI: 10.6009/jjrt.2019_jsrt_75.10.1125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
As the couch used in external radiation therapy attenuate radiation by interaction, it is necessary to correct attenuation of radiation by inserting a couch model in the treatment planning systems. For a couch whose thickness is different in the superior-inferior direction, it is possible to perform dose calculations with an error within ±1% by using separate different couch models provided by vendors. However, it is difficult to correct attenuation correction accurately with a single couch model. In this study, we created an in-house couch model which can set couch shape and physical density in detail by acquiring CT images of actual couch. When we performed dose calculation by optimizing the physical densities of in-house and vendor couch, it was found that the difference between the measured and the calculated values can be significantly reduced by using in-house couch model. Additionally, by using in-house couch model, it is found that the dose attenuation can be corrected within ±1% for a couch whose thickness is different in the superior-inferior direction.
Collapse
Affiliation(s)
- Takahiro Aoyama
- Department of Radiation Oncology, Aichi Cancer Center Hospital
| | - Hidetoshi Shimizu
- Department of Radiation Oncology, Aichi Cancer Center Hospital.,Graduate School of Radiological Technology, Gunma Prefectural College of Health Sciences
| | - Taiki Isomura
- Department of Radiation Oncology, Aichi Cancer Center Hospital (Current address: Department of Proton Technology, Medipolis Proton Therapy and Research Center)
| | - Tomoki Kitagawa
- Department of Radiation Oncology, Aichi Cancer Center Hospital
| | - Kento Tanaka
- Department of Radiation Oncology, Aichi Cancer Center Hospital (Current address: Department of Radiology, Okazaki City Hospital)
| | - Takeshi Kodaira
- Department of Radiation Oncology, Aichi Cancer Center Hospital
| |
Collapse
|
3
|
Bawazeer O, Herath S, Sarasanandarajah S, Kron T, Dunn L, Deb P. A simple and efficient method to measure beam attenuation through a radiotherapy treatment couch and immobilization devices. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2019; 42:1183-1189. [PMID: 31452056 DOI: 10.1007/s13246-019-00789-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2018] [Accepted: 08/09/2019] [Indexed: 11/29/2022]
Abstract
We propose a simple and efficient method to measure beam attenuation in one or two dimensions using an amorphous silicon electronic portal imaging device (a-Si EPID). The proposed method was validated against ionization chamber measurements. Beam attenuation through treatment couches (Varian Medical Systems) and immobilization devices (CIVCO Radiotherapy, USA) was examined. The dependency of beam attenuation on field size, photon energy, thickness of the couch, and the presence of a phantom were studied. Attenuation images were derived by computing the percentage difference between images obtained without and with a couch or immobilization devices determining the percentage of attenuation at the center and the mean attenuation. The beam attenuation measurements obtained with an a-Si EPID and an ionization chamber agreed to within ± 0.10 to 1.80%. No difference was noted between the center and mean of an attenuated image for a small field size of 5 × 5 cm2, whereas a large field size of 15 × 15 cm2 exhibited differences of up to 1.13%. For an 18 MV beam, the a-Si EPID required additional build-up material for accurate assessment of beam attenuation. The a-Si EPID could measure differences in beam attenuation through an image guided radiotherapy (IGRT) couch regardless of the variabilities in couch thickness. Interestingly, the addition of a phantom reduced the magnitude of attenuation by approximately 1.20% for a field size of 15 × 15 cm2. A simple method is proposed that provides the user with beam attenuation data in either 2D or 1D within a few minutes.
Collapse
Affiliation(s)
- Omemh Bawazeer
- Discipline of Medical Radiations, RMIT University, Melbourne, Australia. .,Discipline of Sciences, Umm Al-Qura University, Mecca, Saudi Arabia.
| | - Sisira Herath
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Australia
| | - Sivananthan Sarasanandarajah
- Discipline of Medical Radiations, RMIT University, Melbourne, Australia.,Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Australia.,Department of Medical Imaging and Radiation Sciences, Monash University, Melbourne, Australia
| | - Tomas Kron
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Australia.,Sir Peter MacCallum Cancer Institute, University of Melbourne, Melbourne, Australia
| | - Leon Dunn
- Epworth Radiation Oncology, Epworth Hospital, Melbourne, Australia
| | - Pradip Deb
- Discipline of Medical Radiations, RMIT University, Melbourne, Australia
| |
Collapse
|
4
|
Rijken J, Kairn T, Crowe S, Muñoz L, Trapp J. A simple method to account for skin dose enhancement during treatment planning of VMAT treatments of patients in contact with immobilization equipment. J Appl Clin Med Phys 2018; 19:239-245. [PMID: 29934993 PMCID: PMC6036355 DOI: 10.1002/acm2.12394] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2018] [Revised: 05/29/2018] [Accepted: 06/01/2018] [Indexed: 12/31/2022] Open
Abstract
Purpose The ability to accurately predict skin doses and thereby design radiotherapy treatments that balance the likelihood of skin reactions against other treatment objectives is especially important when hypofractionated prescription regimes are used. However, calculations of skin dose provided by many commercial radiotherapy treatment planning systems are known to be inaccurate, especially if the presence of immobilization equipment is not accurately taken into account. This study proposes a simple method by which the accuracy of skin dose calculations can be substantially improved, to allow informed evaluation of volumetric modulated arc therapy (VMAT) treatment plans. Method A simple method was developed whereby dose calculation is split into grid regions, each with a correction factor which determines MU scaling for skin dose calculation. Correction factors were derived from film measurements made using a geometrically simple phantom in partial contact with a vacuum immobilization device. This method was applied to two different test treatments, planned for delivery to a humanoid phantom with a hypofractionated stereotactic body radiotherapy technique, and results were verified using film measurements of surface dose. Results Compared to the measured values, calculations of skin dose volumes corresponding to different grade tissue reactions were greatly improved through use of the method employed in this study. In some cases, the accuracy of skin dose evaluation improved by 76% and brought values to within 3% of those measured. Conclusion The method of skin dose calculation in this study is simple, can be made as accurate as the user requires and is applicable for various immobilization systems. This concept has been verified through use on SBRT lung treatment plans and will aid clinicians in predicting skin response in patients.
Collapse
Affiliation(s)
- James Rijken
- Genesis Care, Flinders Private Hospital, Bedford Park, SA, Australia.,Queensland University of Technology, Brisbane, QLD, Australia
| | - Tanya Kairn
- Queensland University of Technology, Brisbane, QLD, Australia.,Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia
| | - Scott Crowe
- Queensland University of Technology, Brisbane, QLD, Australia.,Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia
| | - Luis Muñoz
- Genesis Care, Flinders Private Hospital, Bedford Park, SA, Australia
| | - Jamie Trapp
- Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia
| |
Collapse
|
5
|
Sheykhoo A, Abdollahi S, Hadizadeh Yazdi MH, Ghorbani M, Mohammadi M. Effects of Siemens TT-D carbon fiber table top on beam attenuation, and build up region of 6 MV photon beam. Rep Pract Oncol Radiother 2017; 22:19-28. [PMID: 27790074 PMCID: PMC5071548 DOI: 10.1016/j.rpor.2016.09.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2015] [Revised: 06/29/2016] [Accepted: 09/01/2016] [Indexed: 10/20/2022] Open
Abstract
AIM This study deals with Monte Carlo simulations of the effects which the 550 TXT carbon fiber couch can have on the relevant parameters of a 6 MV clinical photon beam in three field sizes. BACKGROUND According to the reports issued by the International Commission on Radiation Units and Measurements (ICRU), the calculated dose across a high gradient distribution should be within 2% of the relative dose, or within 0.2 cm of the isodose curve position in the target volume. Nowadays, the use of posterior oblique beam has become a common practice. It is clear that, in radiotherapy, the presence of the couch affects the beam intensity and, as a result, the skin dose. MATERIALS AND METHODS Firstly, Siemens linear accelerator validation for 6 MV photon beam was performed, and satisfactory agreement between Monte Carlo and experimental data for various field sizes was observed. Secondly, the couch transmission factor for the reference field size and depth was computed, and the skin dose enhancement by the couch was assessed. RESULTS The largest impact of the carbon fiber couch effect was observed for the 5 × 5 cm2 field size. Such evaluation has not been reported for this couch before. CONCLUSION Despite providing minimal attenuation for the primary radiation, the assumption that carbon fiber couches are radiotranslucent is not valid, and the effects of couches of this type on the transmission factor, and on the skin dose should be carefully investigated for each field size and depth.
Collapse
Affiliation(s)
- Asma Sheykhoo
- Physics Department, Faculty of Sciences, Ferdowsi University of Mashhad, Mashhad, Iran
- Medical Physics Department, Reza Radiation Oncology Center, Mashhad, Iran
| | - Sara Abdollahi
- Medical Physics Department, Reza Radiation Oncology Center, Mashhad, Iran
| | | | - Mahdi Ghorbani
- Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mohammad Mohammadi
- Department of Medical Physics, Faculty of Medicine, Hamadan University of Medical Sciences, Hamadam, Iran
- Department of Medical Physics, Royal Adelaide Hospital, Adelaide, South Australia, Australia
| |
Collapse
|
6
|
Duggar WN, Nguyen A, Stanford J, Morris B, Yang CC. Modeling treatment couches in the Pinnacle treatment planning system: Especially important for arc therapy. Med Dosim 2015; 41:34-41. [PMID: 26342567 DOI: 10.1016/j.meddos.2015.07.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2014] [Revised: 06/27/2015] [Accepted: 07/08/2015] [Indexed: 11/25/2022]
Abstract
This study is to demonstrate the importance and a method of properly modeling the treatment couch for dose calculation in patient treatment using arc therapy. The 2 treatment couch tops-Aktina AK550 and Elekta iBEAM evo-of Elekta LINACs were scanned using Philips Brilliance Big Bore CT Simulator. Various parts of the couch tops were contoured, and their densities were measured and recorded on the Pinnacle treatment planning system (TPS) using the established computed tomography density table. These contours were saved as organ models to be placed beneath the patient during planning. Relative attenuation measurements were performed following procedures outlined by TG-176 as well as absolute dose comparison of static fields of 10 × 10 cm(2) that were delivered through the couch tops with that calculated in the TPS with the couch models. A total of 10 random arc therapy treatment plans (5 volumetric-modulated arc therapy [VMAT] and 5 stereotactic body radiation therapy [SBRT]), using 24 beams, were selected for this study. All selected plans were calculated with and without couch modeling. Each beam was evaluated using the Delta(4) dosimetry system (Delta(4)). The Student t-test was used to determine statistical significance. Independent reviews were exploited as per the Imaging and Radiation Oncology Core head and neck credentialing phantom. The selected plans were calculated on the actual patient anatomies with and without couch modeling to determine potential clinical effects. Large relative beam attenuations were noted dependent on which part of the couch top beams were passing through. Substantial improvements were also noted for static fields both calculated with the TPS and delivered physically when the couch models were included in the calculation. A statistically significant increase in agreement was noted for dose difference, distance to agreement, and γ-analysis with the Delta(4) on VMAT and SBRT plans. A credentialing review showed improvement in treatment delivery after couch modeling with both thermoluminescent dosimeter doses and film analysis. Furthermore, analysis of treatment plans with and without using the couch model showed a statistically significant reduction in planning target volume coverage and increase in skin dose. In conclusion, ignoring the treatment couch, a common practice when generating a patient treatment plan, can overestimate the dose delivered especially for arc therapy. This work shows that explicitly modeling the couch during planning can meaningfully improve the agreement between calculated and measured dose distributions. Because of this project, we have implemented the couch models clinically across all treatment plans.
Collapse
Affiliation(s)
- William Neil Duggar
- Department of Radiation Oncology, University of Mississippi Medical Center, Jackson, MS.
| | - Alex Nguyen
- Ironwood Cancer and Research Center, Chandler, AZ
| | - Jason Stanford
- Department of Radiation Oncology, University of Mississippi Medical Center, Jackson, MS
| | - Bart Morris
- Department of Radiation Oncology, University of Mississippi Medical Center, Jackson, MS
| | - Claus C Yang
- Department of Radiation Oncology, University of Mississippi Medical Center, Jackson, MS
| |
Collapse
|
7
|
Park JI, Ye SJ, Kim HJ, Park JM. Dosimetric effects of immobilization devices on SABR for lung cancer using VMAT technique. J Appl Clin Med Phys 2015; 16:5217. [PMID: 25679178 PMCID: PMC5689970 DOI: 10.1120/jacmp.v16i1.5217] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2014] [Revised: 10/19/2014] [Accepted: 10/06/2014] [Indexed: 12/31/2022] Open
Abstract
The purpose of this study was to investigate the dosimetric effects of immobilization devices on the dose distributions of stereotactic ablative radiotherapy (SABR) for lung cancer using volumetric‐modulated arc therapy (VMAT) technique. A total of 30 patients who underwent SABR for lung cancer were selected retrospectively. Every patient was immobilized using Body Pro‐Lok with a vacuum bag customized for each patient body shape. Structure sets were generated to include the patient body inside the body structure with and without the immobilization device. Dose distributions, with and without the immobilization device, were calculated using identical VMAT plans for each patient. Correlations between the change in dose‐volumetric parameters and the MU fraction of photon beams penetrating through the immobilization device were analyzed with Pearson correlation coefficients (r). The maximum change in D95%,D100%, and the minimum, maximum and mean dose to the planning target volume (PTV) due to the immobilization device were 5%, 7%, 4%, 5%, and 5%, respectively. The maximum changes in the maximum dose to the spinal cord, esophagus, heart, and trachea were 1.3 Gy, 0.9 Gy, 1 Gy, and 1.7 Gy, respectively. Strong correlations were observed between the changes in PTV D95%, the minimum, the maximum, and the mean dose to the PTV, the maximum dose to the esophagus and heart, and the MU fractions, showing values of r higher than 0.7. The decrease in dose to the target volume was considerable for lung SABR using VMAT technique, especially when MU fraction was large. PACS number: 87.55.‐x
Collapse
Affiliation(s)
- Jong In Park
- Seoul National University Graduate School of Convergence Science and Technology.
| | | | | | | |
Collapse
|
8
|
Olch AJ, Gerig L, Li H, Mihaylov I, Morgan A. Dosimetric effects caused by couch tops and immobilization devices: Report of AAPM Task Group 176. Med Phys 2014; 41:061501. [DOI: 10.1118/1.4876299] [Citation(s) in RCA: 78] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
9
|
Kinhikar RA, Pandey VP, Jose RK, Mahantshetty U, Dhote DS, Deshpande DD, Shrivastava SK. Investigation on the effect of sharp phantom edges on point dose measurement during patient-specific dosimetry with Rapid Arc. J Med Phys 2013; 38:139-42. [PMID: 24049321 PMCID: PMC3775038 DOI: 10.4103/0971-6203.116373] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2013] [Revised: 06/18/2013] [Accepted: 07/05/2013] [Indexed: 11/21/2022] Open
Abstract
The objective of this work was to investigate and quantify the effect of sharp edges of the phantom on the point dose measurement during patient-specific dosimetry with Rapid Arc (RA). Ten patients with carcinoma of prostate were randomly selected for this dosimetric study. Rapid Arc plans were generated with 6 MV X-rays in the Eclipse (v 8.6.14) with single arc (clockwise). Dosimetry verification plans were generated for two phantoms (cylindrical and rectangular). The cylindrical phantom was solid water (diameter 34 cm) and the rectangular phantom was a water phantom (25 cm × 25 cm × 10 cm). These phantoms were pre-scanned in computed tomography (CT) machine with cylindrical ionization chamber (FC65) in place. The plans were delivered with Novalis Tx linear accelerator with 6 MV X-rays for both the phantoms separately. The measured dose was compared with the planned dose for both the phantoms. Mean percentage deviation between measured and planned doses was found to be 4.19 (SD 0.82) and 3.63 (SD 0.89) for cylindrical and rectangular phantoms, respectively. No significant dosimetric variation was found due to the geometry (sharp edges) of the phantom. The sharp edges of the phantom do not perturb the patient specific Rapid Arc dosimetry significantly.
Collapse
Affiliation(s)
- R A Kinhikar
- Department of Medical Physics, Tata Memorial Hospital, Mumbai, India
| | | | | | | | | | | | | |
Collapse
|
10
|
Tominaga H, Araki F, Shimohigashi Y, Kanetake N, Tomiyama Y, Kawasaki K, Iwashita Y, Sakata J, Okuda T. [Dose impact of a carbon fiber couch for stereotactic body radiation therapy of lung tumors]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2013; 69:400-6. [PMID: 23609862 DOI: 10.6009/jjrt.2013_jsrt_69.4.400] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The aim of this study was to measure the dose attenuation caused by a carbon fiber radiation therapy table (Imaging Couch Top; ICT, BrainLab) and to evaluate the dosimetric impact of ICT during stereotactic body radiation therapy (SBRT) in lung tumors. The dose attenuation of ICT was measured using an ionization chamber and modeled by means of a treatment planning system (TPS). SBRT was planned with and without ICT in a lung tumor phantom and ten cases of clinical lung tumors. The results were analyzed from isocenter doses and a dose-volume histogram (DVH): D95, Dmean, V20, V5, homogeneity index (HI), and conformity index (CI). The dose attenuation of the ICT modeled with TPS agreed to within ±1% of the actually measured values. The isocenter doses, D95 and Dmean with and without ICT showed differences of 4.1-5% for posterior single field and three fields in the phantom study, and differences of 0.6-2.4% for five fields and rotation in the phantom study and six fields in ten clinical cases. The dose impact of ICT was not significant for five or more fields in SBRT. It is thus possible to reduce the dose effect of ICT by modifying the beam angle and beam weight in the treatment plan.
Collapse
|
11
|
Chan MF, Chiu-Tsao ST, Li J, Schupak K, Parhar P, Burman C. Confirmation of Skin Doses Resulting from Bolus Effect of Intervening Alpha-cradle and Carbon Fiber Couch in Radiotherapy. Technol Cancer Res Treat 2012; 11:571-81. [PMID: 22712603 DOI: 10.7785/tcrt.2012.500269] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
In this study, we verified the treatment planning calculations of skin doses with the incorporation of the bolus effect due to the intervening alpha-cradle (AC) and carbon fiber couch (CFC) using radiochromic EBT2 films. A polystyrene phantom (25 × 25 × 15 cm3) with six EBT2 films separated by polystyrene slabs, at depths of 0, 0.1, 0.2, 0.5, 1, 1.4 cm, was positioned above an AC, which was ~1 cm thick. The phantom and AC assembly were CT scanned and the CT-images were transferred to the treatment planning system (TPS) for calculations in three scenarios: (A) ignoring AC and CFC, (B) accounting for AC only, (C) accounting for both AC and CFC. A single posterior 10 × 10 cm2 field, a pair of posterior-oblique 10 × 10 cm2 fields, and a posterior IMRT field (6 MV photons from a Varian Trilogy linac) were planned. For each radiation field configuration, the same MU were used in all three scenarios in the TPS. Each plan for scenario C was delivered to expose a stack of EBT2 films in the phantom through AC and CFC. In addition, in vivo EBT2 film measurement on a lung cancer patient immobilized with AC undergoing IMRT was also included in this study. Point doses and planar distributions generated from the TPS for the three scenarios were compared with the data from the EBT2 film measurements. For all the field arrangements, the EBT2 film data including the in vivo measurement agreed with the doses calculated for scenario (C), within the uncertainty of the EBT2 measurements (~4%). For the single posterior field (a pair of posterior-oblique fields), the TPS generated doses were lower than the EBT2 doses by 34%, 33%, 31%, 13% (34%, 31%, 31%, 11%) for scenario A and by 27%, 25%, 22%, 8% (25%, 21%, 21%, 6%) for scenario B at the depths of 0, 0.1, 0.2, 0.5 cm, respectively. For the IMRT field, the 2D dose distributions at each depth calculated in scenario C agree with those measured data. When comparing the central axis doses for the IMRT field, we found the TPS generated doses for scenario A (B) were lower than the EBT2 data by 35%, 34%, 31%, 16% (29%, 26%, 23%, 10%) at the depths of 0, 0.1, 0.2, 0.5 cm, respectively. There were no significant differences for the depths of 1.0 and 1.4 cm for all the radiation fields studied. TPS calculation of doses in the skin layers accounting for AC and CFC was verified by EBT2 film data. Ignoring the presence of AC and/or CFC in TPS calculation would significantly underestimate the doses in the skin layers. For the clinicians, as more hypofractionated regimens and stereotactic regimens are being used, this information will be useful to avoid potential serious skin toxicities, and also assist in clinical decisions and report these doses accurately to relevant clinical trials/cooperative groups, such as RTOG.
Collapse
Affiliation(s)
- Maria F. Chan
- Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, 136 Mountain View Blvd., Basking Ridge, NJ 07920, USA
| | | | - Jingdong Li
- Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, 136 Mountain View Blvd., Basking Ridge, NJ 07920, USA
| | - Karen Schupak
- Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, 136 Mountain View Blvd., Basking Ridge, NJ 07920, USA
| | - Preeti Parhar
- Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, 136 Mountain View Blvd., Basking Ridge, NJ 07920, USA
| | - Chandra Burman
- Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, 136 Mountain View Blvd., Basking Ridge, NJ 07920, USA
| |
Collapse
|
12
|
Njeh CF, Parker J, Spurgin J, Rhoe E. A validation of carbon fiber imaging couch top modeling in two radiation therapy treatment planning systems: Philips Pinnacle3 and BrainLAB iPlan RT Dose. Radiat Oncol 2012; 7:190. [PMID: 23140425 PMCID: PMC3549905 DOI: 10.1186/1748-717x-7-190] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2012] [Accepted: 10/25/2012] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Carbon fiber (CF) is now the material of choice for radiation therapy couch tops. Initial designs included side metal bars for rigidity; however, with the advent of IGRT, involving on board imaging, new thicker CF couch tops without metal bars have been developed. The new design allows for excellent imaging at the expense of potentially unacceptable dose attenuation and perturbation. OBJECTIVES We set out to model the BrainLAB imaging couch top (ICT) in Philips Pinnacle(3) treatment planning system (TPS), to validate the already modeled ICT in BrainLAB iPlan RT Dose treatment planning system and to compute the magnitude of the loss in skin sparing. RESULTS Using CF density of 0.55 g/cm(3) and foam density of 0.03 g/cm(3), we demonstrated an excellent agreement between measured dose and Pinnacle(3) TPS computed dose using 6 MV beam. The agreement was within 1% for all gantry angle measured except for 120°, which was 1.8%. The measured and iPlan RT Dose TPS computed dose agreed to within 1% for all gantry angles and field sizes measured except for 100° where the agreement was 1.4% for 10 cm × 10 cm field size. Predicted attenuation through the couch by iPlan RT Dose TPS (3.4% - 9.5%) and Pinnacle(3) TPS (2% - 6.6%) were within the same magnitude and similar to previously reported in the literature. Pinnacle(3) TPS estimated an 8% to 20% increase in skin dose with increase in field size. With the introduction of the CF couch top, it estimated an increase in skin dose by approximately 46 - 90%. The clinical impact of omitting the couch in treatment planning will be dependent on the beam arrangement, the percentage of the beams intersecting the couch and their angles of incidence. CONCLUSION We have successfully modeled the ICT in Pinnacle(3) TPS and validated the modeled ICT in iPlan RT Dose. It is recommended that the ICT be included in treatment planning for all treatments that involve posteriors beams. There is a significant increase in skin dose that is dependent on the percentage of the beam passing through the couch and the angle of incidence.
Collapse
|