1
|
Optical imaging of produced light in water during irradiation of gamma photons lower energy than the Cerenkov-light threshold. Appl Radiat Isot 2020; 157:109037. [DOI: 10.1016/j.apradiso.2020.109037] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2019] [Revised: 01/04/2020] [Accepted: 01/06/2020] [Indexed: 11/19/2022]
|
2
|
Hirano Y, Yamamoto S. Estimation of the fractions of luminescence of water at higher energy than Cerenkov-light threshold for various types of radiation. JOURNAL OF BIOMEDICAL OPTICS 2019; 24:1-9. [PMID: 31218874 PMCID: PMC6977019 DOI: 10.1117/1.jbo.24.6.066005] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/02/2019] [Accepted: 05/21/2019] [Indexed: 06/09/2023]
Abstract
Although the luminescence of water at a lower energy than the Cerenkov-light (CL) threshold has been found for various types of radiation, the fractions of the luminescence of water to the total produced light have not been obvious for radiations at a higher energy than the CL threshold because it is difficult to separate these two types of light. Thus, we used a Monte Carlo simulation to estimate the fractions of the luminescence of water for various types of radiation at a higher energy than the CL threshold to confirm the major component of the produced light. After we confirmed that the estimated light production of the luminescence of water could adequately simulate the experimental results, we calculated the produced light photons of this luminescence and the CL from water for protons (170 MeV), carbon ions (330 MeV/n), high-energy x-ray (6 MV) from a linear accelerator (LINAC), high-energy electrons (9 MeV) from LINAC, positrons (F-18, C-11, O-15, and N-13), and high-energy gamma photon radionuclides (Co-60). For protons, the major fraction of the produced light was the luminescence of water in addition to the CL from the prompt gamma photons produced by the nuclear interactions. For carbon ions, the major fraction of the produced light was the luminescence of water and the CL produced by the secondary electrons in addition to the prompt gamma photons produced by the nuclear interactions. For high-energy x-ray and electrons from LINAC, the fractions of luminescence of water were ∼0.1 % to 0.2%. The fractions of luminescence of water for positrons were 0.2% to 1.5% and that for Co-60 was 0.4%. We conclude that the major fractions of light produced from x-ray and electrons from LINAC, positron radionuclides, and the Co-60 source are CL, with fractions of the luminescence of water from <0.1 % to 1.5%.
Collapse
Affiliation(s)
- Yoshiyuki Hirano
- Nagoya University Graduate School of Medicine, Department of Radiological and Medical Laboratory Sciences, Nagoya, Japan
| | - Seiichi Yamamoto
- Nagoya University Graduate School of Medicine, Department of Radiological and Medical Laboratory Sciences, Nagoya, Japan
| |
Collapse
|
3
|
Stammes MA, Bugby SL, Porta T, Pierzchalski K, Devling T, Otto C, Dijkstra J, Vahrmeijer AL, de Geus-Oei LF, Mieog JSD. Modalities for image- and molecular-guided cancer surgery. Br J Surg 2018; 105:e69-e83. [PMID: 29341161 DOI: 10.1002/bjs.10789] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2017] [Revised: 10/25/2017] [Accepted: 11/05/2017] [Indexed: 12/19/2022]
Abstract
BACKGROUND Surgery is the cornerstone of treatment for many solid tumours. A wide variety of imaging modalities are available before surgery for staging, although surgeons still rely primarily on visual and haptic cues in the operating environment. Image and molecular guidance might improve the adequacy of resection through enhanced tumour definition and detection of aberrant deposits. Intraoperative modalities available for image- and molecular-guided cancer surgery are reviewed here. METHODS Intraoperative cancer detection techniques were identified through a systematic literature search, with selection of peer-reviewed publications from January 2012 to January 2017. Modalities were reviewed, described and compared according to 25 predefined characteristics. To summarize the data in a comparable way, a three-point rating scale was applied to quantitative characteristics. RESULTS The search identified ten image- and molecular-guided surgery techniques, which can be divided into four groups: conventional, optical, nuclear and endogenous reflectance modalities. Conventional techniques are the most well known imaging modalities, but unfortunately have the drawback of a defined resolution and long acquisition time. Optical imaging is a real-time modality; however, the penetration depth is limited. Nuclear modalities have excellent penetration depth, but their intraoperative use is limited by the use of radioactivity. Endogenous reflectance modalities provide high resolution, although with a narrow field of view. CONCLUSION Each modality has its strengths and weaknesses; no single technique will be suitable for all surgical procedures. Strict selection of modalities per cancer type and surgical requirements is required as well as combining techniques to find the optimal balance.
Collapse
Affiliation(s)
- M A Stammes
- Department of Radiology, Leiden University Medical Centre, Leiden, The Netherlands.,Percuros, Enschede, The Netherlands
| | - S L Bugby
- Space Research Centre, Department of Physics and Astronomy, University of Leicester, Leicester, UK
| | - T Porta
- Maastricht MultiModal Molecular Imaging Institute (M4I), Division of Imaging Mass Spectrometry, Maastricht University, Maastricht, The Netherlands
| | - K Pierzchalski
- Maastricht MultiModal Molecular Imaging Institute (M4I), Division of Imaging Mass Spectrometry, Maastricht University, Maastricht, The Netherlands
| | | | - C Otto
- Medical Cell Bio Physics, University of Twente, Enschede, The Netherlands
| | - J Dijkstra
- Department of Radiology, Leiden University Medical Centre, Leiden, The Netherlands
| | - A L Vahrmeijer
- Department of Surgery, Leiden University Medical Centre, Leiden, The Netherlands
| | - L-F de Geus-Oei
- Department of Radiology, Leiden University Medical Centre, Leiden, The Netherlands.,Biomedical Photonic Imaging Group, MIRA Institute, University of Twente, Enschede, The Netherlands
| | - J S D Mieog
- Department of Surgery, Leiden University Medical Centre, Leiden, The Netherlands
| |
Collapse
|
4
|
Padmanabhan P, Nedumaran AM, Mishra S, Pandarinathan G, Archunan G, Gulyás B. The Advents of Hybrid Imaging Modalities: A New Era in Neuroimaging Applications. ACTA ACUST UNITED AC 2017; 1:e1700019. [PMID: 32646180 DOI: 10.1002/adbi.201700019] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2017] [Revised: 03/30/2017] [Indexed: 01/29/2023]
Abstract
Hybrid Imaging modalities have shown great potential in medical imaging and diagnosis. A more comprehensive and targeted view of neurological disorders can be achieved by blending the anatomical and functional perspectives through hybridization. With consistently improving technologies, there have been many developments in fused imaging techniques over the past few decades. This article provides an overview of various bimodal and trimodal hybrid imaging techniques being developed and explored for neuroimaging applications. Recent advancements and potentials are discussed for single photon emission computed tomography-computed tomography (SPECT-CT), positron emission tomography-CT (PET-CT), PET-magnetic resonance imaging (PET-MRI), electroencephalography-functional magnetic resonance imaging (EEG-fMRI), magnetoencephalography-fMRI (MEG-fMRI), EEG-near-infrared spectroscopy (EEG-NIRS), magnetic resonance-PET-EEG (MR-PET-EEG) and MR-PET-CT in the perspective of neuroimaging. A comparison of these hybrid approaches is provided on a single platform to analyze their performance on the basis of several common factors essential for imaging and analyzing neurological disorders and in vivo molecular processes. This article also provides an overview of recently developed advanced imaging technologies that are being hybridized with other imaging modalities and being explored as potential techniques for neuroscience. Novel approaches and clinical applications of hybrid neuroimaging are anticipated with inclusion of new technologies, better sensing capabilities, multimodal probes, and improved hybridization.
Collapse
Affiliation(s)
- Parasuraman Padmanabhan
- Lee Kong Chian School of Medicine, Nanyang Technological University, 59 Nanyang Drive, 636921, Singapore
| | - Anu Maashaa Nedumaran
- Lee Kong Chian School of Medicine, Nanyang Technological University, 59 Nanyang Drive, 636921, Singapore.,Department of Biomedical Engineering, SRM University, SRM Nagar, Kattankulathur, Kanchipuram, Tamil Nadu, 603203, India
| | - Sachin Mishra
- Lee Kong Chian School of Medicine, Nanyang Technological University, 59 Nanyang Drive, 636921, Singapore
| | - Ganesh Pandarinathan
- Lee Kong Chian School of Medicine, Nanyang Technological University, 59 Nanyang Drive, 636921, Singapore.,Department of Biomedical Engineering, SRM University, SRM Nagar, Kattankulathur, Kanchipuram, Tamil Nadu, 603203, India
| | - Govindaraju Archunan
- Centre for Pheromone Technology, Department of Animal Science, Bharathidasan University, Tiruchirappalli, 620024, India
| | - Balázs Gulyás
- Lee Kong Chian School of Medicine, Nanyang Technological University, 59 Nanyang Drive, 636921, Singapore
| |
Collapse
|
5
|
Schober O, Dössel O, Ermert H, Requardt H, Ziegler S, Adam G. [Imaging in clinic and research: contribution to individualized medicine?]. Nuklearmedizin 2017. [PMID: 29533421 DOI: 10.3413/2017-05-0002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
6
|
Lin H, Zhang R, Gunn JR, Esipova TV, Vinogradov S, Gladstone DJ, Jarvis LA, Pogue BW. Comparison of Cherenkov excited fluorescence and phosphorescence molecular sensing from tissue with external beam irradiation. Phys Med Biol 2016; 61:3955-68. [PMID: 27120085 DOI: 10.1088/0031-9155/61/10/3955] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Ionizing radiation delivered by a medical linear accelerator (LINAC) generates Cherenkov emission within the treated tissue. A fraction of this light, in the 600-900 nm wavelength region, propagates through centimeters of tissue and can be used to excite optical probes in vivo, enabling molecular sensing of tissue analytes. The success of isolating the emission signal from this Cherenkov excitation background is dependent on key factors such as: (i) the Stokes shift of the probe spectra; (ii) the excited state lifetime; (iii) the probe concentration; (iv) the depth below the tissue surface; and (v) the radiation dose used. Previous studies have exclusively focused on imaging phosphorescent dyes, rather than fluorescent dyes. However there are only a few biologically important phosphorescent dyes and yet in comparison there are thousands of biologically relevant fluorescent dyes. So in this study the focus was a study of efficacy of Cherenkov-excited luminescence using fluorescent commercial near-infrared probes, IRDye 680RD, IRDye 700DX, and IRDye 800CW, and comparing them to the well characterized phosphorescent probe Oxyphor PtG4, an oxygen sensitive dye. Each probe was excited by Cherenkov light from a 6 MV external radiation beam, and measured in continuous wave or time-gated modes. The detection was performed by spectrally resolving the luminescence signals, and measuring them with spectrometer-based separation on an ICCD detector. The results demonstrate that IRDye 700DX and PtG4 allowed for the maximal signal to noise ratio. In the case of the phosphorescent probe, PtG4, with emission decays on the microsecond (μs) time scale, time-gated acquisition was possible, and it allowed for higher efficacy in terms of the probe concentration and detection depth. Phantoms containing the probe at 5 mm depth could be detected at concentrations down to the nanoMolar range, and at depths into the tissue simulating phantom near 3 cm. In vivo studies showed that 5 nmol of dye was readily detected with radiation doses less than 5 cGy. Since concentration, radiation dose and depth each contribute to the level of the detected signal, it may be possible to improve any of these parameters at expense of the others. This paradigm of nanoMolar sensitivity for optical reporters in vivo introduces the concept of molecular sensing of tumors during therapy or diagnostically with biologically relevant concentrations of fluorescent reporters.
Collapse
Affiliation(s)
- Huiyun Lin
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA. MOE Key Laboratory of OptoElectronic Science and Technology for Medicine, Fujian Provincial Key Laboratory for Photonics Technology, Fujian Normal University, Fujian 350007, People's Republic of China
| | | | | | | | | | | | | | | |
Collapse
|