1
|
Qiu Z, Olberg S, den Hertog D, Ajdari A, Bortfeld T, Pursley J. Online adaptive planning methods for intensity-modulated radiotherapy. Phys Med Biol 2023; 68:10.1088/1361-6560/accdb2. [PMID: 37068488 PMCID: PMC10637515 DOI: 10.1088/1361-6560/accdb2] [Citation(s) in RCA: 14] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2022] [Accepted: 04/17/2023] [Indexed: 04/19/2023]
Abstract
Online adaptive radiation therapy aims at adapting a patient's treatment plan to their current anatomy to account for inter-fraction variations before daily treatment delivery. As this process needs to be accomplished while the patient is immobilized on the treatment couch, it requires time-efficient adaptive planning methods to generate a quality daily treatment plan rapidly. The conventional planning methods do not meet the time requirement of online adaptive radiation therapy because they often involve excessive human intervention, significantly prolonging the planning phase. This article reviews the planning strategies employed by current commercial online adaptive radiation therapy systems, research on online adaptive planning, and artificial intelligence's potential application to online adaptive planning.
Collapse
Affiliation(s)
- Zihang Qiu
- Department of Business Analytics, University of Amsterdam, The Netherlands
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, United States of America
| | - Sven Olberg
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, United States of America
| | - Dick den Hertog
- Department of Business Analytics, University of Amsterdam, The Netherlands
| | - Ali Ajdari
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, United States of America
| | - Thomas Bortfeld
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, United States of America
| | - Jennifer Pursley
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, United States of America
| |
Collapse
|
2
|
Bessieres I, Lorenzo O, Bertaut A, Petitfils A, Aubignac L, Boudet J. Online adaptive radiotherapy and dose delivery accuracy: A retrospective analysis. J Appl Clin Med Phys 2023:e14005. [PMID: 37097765 PMCID: PMC10402677 DOI: 10.1002/acm2.14005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 01/16/2023] [Accepted: 04/04/2023] [Indexed: 04/26/2023] Open
Abstract
PURPOSE With online adaptive radiotherapy (ART), patient-specific quality assurance (PSQA) testing cannot be performed prior to delivery of the adapted treatment plan. Consequently, the dose delivery accuracy of adapted plans (i.e., the ability of the system to interpret and deliver the treatment as planned) are not initially verified. We investigated the variation in dose delivery accuracy of ART on the MRIdian 0.35 T MR-linac (Viewray Inc., Oakwood, USA) between initial plans and their respective adapted plans, by analyzing PSQA results. METHODS We considered the two main digestive localizations treated with ART (liver and pancreas). A total of 124 PSQA results acquired with the ArcCHECK (Sun Nuclear Corporation, Melbourne, USA) multidetector system were analyzed. PSQA result variations between the initial plans and their respective adapted plans were statistically investigated and compared with the variation in MU number. RESULTS For the liver, limited deterioration in PSQA results was observed, and was within the limits of clinical tolerance (Initial = 98.2%, Adapted = 98.2%, p = 0.4503). For pancreas plans, only a few significant deteriorations extending beyond the limits of clinical tolerance were observed and were due to specific, complex anatomical configurations (Initial = 97.3%, Adapted = 96.5%, p = 0.0721). In parallel, we observed an influence of the increase in MU number on the PSQA results. CONCLUSION We show that the dose delivery accuracy of adapted plans, in terms of PSQA results, is preserved in ART processes on the 0.35 T MR-linac. Respecting good practices, and minimizing the increase in MU number can help to preserve the accuracy of delivery of adapted plans as compared to their respective initial plans.
Collapse
Affiliation(s)
- Igor Bessieres
- Department of Medical Physics, Centre Georges François Leclerc, Dijon, France
| | - Olivier Lorenzo
- Department of Medical Physics, Centre Georges François Leclerc, Dijon, France
| | - Aurélie Bertaut
- Methodology, Data-Management and Biostatistics Unit, Centre Georges-François Leclerc, Dijon, France
| | - Aurélie Petitfils
- Department of Medical Physics, Centre Georges François Leclerc, Dijon, France
| | - Léone Aubignac
- Department of Medical Physics, Centre Georges François Leclerc, Dijon, France
| | - Julien Boudet
- Department of Medical Physics, Centre Georges François Leclerc, Dijon, France
| |
Collapse
|
3
|
Nierer L, Eze C, da Silva Mendes V, Braun J, Thum P, von Bestenbostel R, Kurz C, Landry G, Reiner M, Niyazi M, Belka C, Corradini S. Dosimetric benefit of MR-guided online adaptive radiotherapy in different tumor entities: liver, lung, abdominal lymph nodes, pancreas and prostate. Radiat Oncol 2022; 17:53. [PMID: 35279185 PMCID: PMC8917666 DOI: 10.1186/s13014-022-02021-6] [Citation(s) in RCA: 26] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Accepted: 02/27/2022] [Indexed: 01/18/2023] Open
Abstract
Background Hybrid magnetic resonance (MR)-Linac systems have recently been introduced into clinical practice. The systems allow online adaption of the treatment plan with the aim of compensating for interfractional anatomical changes. The aim of this study was to evaluate the dose volume histogram (DVH)-based dosimetric benefits of online adaptive MR-guided radiotherapy (oMRgRT) across different tumor entities and to investigate which subgroup of plans improved the most from adaption. Methods Fifty patients treated with oMRgRT for five different tumor entities (liver, lung, multiple abdominal lymph nodes, pancreas, and prostate) were included in this retrospective analysis. Various target volume (gross tumor volume GTV, clinical target volume CTV, and planning target volume PTV) and organs at risk (OAR) related DVH parameters were compared between the dose distributions before and after plan adaption. Results All subgroups clearly benefited from online plan adaption in terms of improved PTV coverage. For the liver, lung and abdominal lymph nodes cases, a consistent improvement in GTV coverage was found, while many fractions of the prostate subgroup showed acceptable CTV coverage even before plan adaption. The largest median improvements in GTV near-minimum dose (D98%) were found for the liver (6.3%, p < 0.001), lung (3.9%, p < 0.001), and abdominal lymph nodes (6.8%, p < 0.001) subgroups. Regarding OAR sparing, the largest median OAR dose reduction during plan adaption was found for the pancreas subgroup (-87.0%). However, in the pancreas subgroup an optimal GTV coverage was not always achieved because sparing of OARs was prioritized. Conclusion With online plan adaptation, it was possible to achieve significant improvements in target volume coverage and OAR sparing for various tumor entities and account for interfractional anatomical changes.
Collapse
|
4
|
Hall WA, Paulson E, Li XA, Erickson B, Schultz C, Tree A, Awan M, Low DA, McDonald BA, Salzillo T, Glide-Hurst CK, Kishan AU, Fuller CD. Magnetic resonance linear accelerator technology and adaptive radiation therapy: An overview for clinicians. CA Cancer J Clin 2022; 72:34-56. [PMID: 34792808 PMCID: PMC8985054 DOI: 10.3322/caac.21707] [Citation(s) in RCA: 51] [Impact Index Per Article: 25.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 09/01/2021] [Accepted: 09/22/2021] [Indexed: 12/25/2022] Open
Abstract
Radiation therapy (RT) continues to play an important role in the treatment of cancer. Adaptive RT (ART) is a novel method through which RT treatments are evolving. With the ART approach, computed tomography or magnetic resonance (MR) images are obtained as part of the treatment delivery process. This enables the adaptation of the irradiated volume to account for changes in organ and/or tumor position, movement, size, or shape that may occur over the course of treatment. The advantages and challenges of ART maybe somewhat abstract to oncologists and clinicians outside of the specialty of radiation oncology. ART is positioned to affect many different types of cancer. There is a wide spectrum of hypothesized benefits, from small toxicity improvements to meaningful gains in overall survival. The use and application of this novel technology should be understood by the oncologic community at large, such that it can be appropriately contextualized within the landscape of cancer therapies. Likewise, the need to test these advances is pressing. MR-guided ART (MRgART) is an emerging, extended modality of ART that expands upon and further advances the capabilities of ART. MRgART presents unique opportunities to iteratively improve adaptive image guidance. However, although the MRgART adaptive process advances ART to previously unattained levels, it can be more expensive, time-consuming, and complex. In this review, the authors present an overview for clinicians describing the process of ART and specifically MRgART.
Collapse
MESH Headings
- History, 20th Century
- History, 21st Century
- Humans
- Magnetic Resonance Imaging, Interventional/history
- Magnetic Resonance Imaging, Interventional/instrumentation
- Magnetic Resonance Imaging, Interventional/methods
- Magnetic Resonance Imaging, Interventional/trends
- Neoplasms/diagnostic imaging
- Neoplasms/radiotherapy
- Particle Accelerators
- Radiation Oncology/history
- Radiation Oncology/instrumentation
- Radiation Oncology/methods
- Radiation Oncology/trends
- Radiotherapy Planning, Computer-Assisted/history
- Radiotherapy Planning, Computer-Assisted/instrumentation
- Radiotherapy Planning, Computer-Assisted/methods
- Radiotherapy Planning, Computer-Assisted/trends
Collapse
Affiliation(s)
- William A. Hall
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Eric Paulson
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - X. Allen Li
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Beth Erickson
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Christopher Schultz
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Alison Tree
- The Royal Marsden National Health Service Foundation Trust and the Institute of Cancer Research, London, United Kingdom
| | - Musaddiq Awan
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Daniel A. Low
- Department of Radiation Oncology, University of California-Los Angeles, Los Angeles, California
| | - Brigid A. McDonald
- Department of Radiation Oncology, The University of Texas, MD Anderson Cancer Center, Houston, Texas
| | - Travis Salzillo
- Department of Radiation Oncology, The University of Texas, MD Anderson Cancer Center, Houston, Texas
| | - Carri K. Glide-Hurst
- Department of Radiation Oncology, University of Wisconsin-Madison, Madison, Wisconsin
| | - Amar U. Kishan
- Department of Radiation Oncology, University of California-Los Angeles, Los Angeles, California
| | - Clifton D. Fuller
- Department of Radiation Oncology, The University of Texas, MD Anderson Cancer Center, Houston, Texas
| |
Collapse
|
5
|
Svecic A, Roberge D, Kadoury S. Prediction of inter-fractional radiotherapy dose plans with domain translation in spatiotemporal embeddings. Med Image Anal 2020; 64:101728. [DOI: 10.1016/j.media.2020.101728] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2019] [Revised: 05/12/2020] [Accepted: 05/12/2020] [Indexed: 01/22/2023]
|
6
|
Liu X, Liang Y, Zhu J, Yu G, Yu Y, Cao Q, Li XA, Li B. A Fast Online Replanning Algorithm Based on Intensity Field Projection for Adaptive Radiotherapy. Front Oncol 2020; 10:287. [PMID: 32195188 PMCID: PMC7063069 DOI: 10.3389/fonc.2020.00287] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2019] [Accepted: 02/19/2020] [Indexed: 11/13/2022] Open
Abstract
Purpose: The purpose of this work was to propose an online replanning algorithm, named intensity field projection (IFP), that directly adjusts intensity distributions for each beam based on the deformation of structures. IFP can be implemented within a reasonably acceptable time frame. Methods and Materials: The online replanning method is based on the gradient-based free form deformation (GFFD) algorithm, which we have previously proposed. The method involves the following steps: The planning computed tomography (CT) and cone-beam CT image are registered to generate a three-dimensional (3-D) deformation field. According to the 3-D deformation field, the registered image and a new delineation are generated. The two-dimensional (2-D) deformation field of ray intensity in each beam direction is determined based on the 3-D deformation field in the region of interest. The 2-D ray intensity distribution in the corresponding beam direction is deformed to generate a new 2-D ray intensity distribution. According to the new 2-D ray intensity distribution, corresponding multi-leaf collimator (MLC), and jaw motion data are generated. The feasibility and advantages of our method have been demonstrated in 20 lung cancer intensity modulated radiation therapy (IMRT) cases. Results: Substantial underdosing in the CTV is seen in the original and the repositioning plans. The average prescription dose coverage (V100%) and D95 for CTV were 100% and 60.3 Gy for the IFP plans compared to 82.6% (P < 0.01) and 44.0 Gy (P < 0.01) for original plans, 86.7% (P < 0.01), and 58.5 Gy (P < 0.01) for repositioning plans. On average, the mean total lung doses were 12.2 Gy for the IFP plan compared to the 12.4 Gy (P < 0.01) and 12.6 Gy (P < 0.01) for the original and the repositioning plans. The entire process of IFP can be completed within 3 min. Conclusions: We proposed an online replanning strategy for automatically correcting interfractional anatomy variations. The preliminary results indicate that the IFP method substantially increased planning speed for online adaptive replanning.
Collapse
Affiliation(s)
- Xiaomeng Liu
- School of Medicine and Life Sciences, University of Jinan-Shandong Academy of Medical Sciences, Jinan, China.,Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China
| | - Yueqiang Liang
- Software Research and Development Department, STFK Medical Device Co, Ltd., Zhangjiagang, China
| | - Jian Zhu
- Shandong Key Laboratory of Medical Physics and Image Processing, School of Physics and Electronics, Shandong Normal University, Jinan, China
| | - Gang Yu
- Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China
| | - Yanyan Yu
- Department of Neurology, Shandong Provincial Qianfoshan Hospital, Jinan, China
| | - Qiang Cao
- Laboratory of Image Science and Technology, Southeast University, Nanjing, Jiangsu, China
| | - X Allen Li
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI, United States
| | - Baosheng Li
- Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China
| |
Collapse
|
7
|
Druet X, Acosta Sanchez E, Soleakhena K, Laprie A, Sáez J, Nougaret S, Riou O, Rigal E, Kibranian L, Palacios M, Membrive I. MRI in medical practice and its future use in radiation oncology. Resume of XXV GOCO Congress (Montpellier) 2017. Rep Pract Oncol Radiother 2019; 24:355-362. [PMID: 31194172 PMCID: PMC6554468 DOI: 10.1016/j.rpor.2019.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2019] [Accepted: 05/11/2019] [Indexed: 11/21/2022] Open
Abstract
This publication is a resume of the GOCO Congress (Montpellier 2017). A part of this congress was about the use of MRI in clinical practice, focused on the oncology field. The role of this tool was described in diagnosis, staging of tumors, evaluation of treatment response and the future use in prognostic and investigation (radiomics). After that, in the context of the present and future uses of MRI in radiation oncology, MRI guided radiotherapy was explained, as a method that allows an increased precision in image guided treatments. This publication is a resume of the GOCO Congress (Montpellier 2017). A part of this congress was about the use of MRI in clinical practice, focused on the oncology field. The role of this tool was described in diagnosis, staging of tumors, evaluation of treatment response and the future use in prognostic and investigation (radiomics).
Collapse
|
8
|
White IM, Scurr E, Wetscherek A, Brown G, Sohaib A, Nill S, Oelfke U, Dearnaley D, Lalondrelle S, Bhide S. Realizing the potential of magnetic resonance image guided radiotherapy in gynaecological and rectal cancer. Br J Radiol 2019; 92:20180670. [PMID: 30933550 PMCID: PMC6592079 DOI: 10.1259/bjr.20180670] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Revised: 02/24/2019] [Accepted: 03/21/2019] [Indexed: 12/25/2022] Open
Abstract
CT-based radiotherapy workflow is limited by poor soft tissue definition in the pelvis and reliance on rigid registration methods. Current image-guided radiotherapy and adaptive radiotherapy models therefore have limited ability to improve clinical outcomes. The advent of MRI-guided radiotherapy solutions provides the opportunity to overcome these limitations with the potential to deliver online real-time MRI-based plan adaptation on a daily basis, a true "plan of the day." This review describes the application of MRI guided radiotherapy in two pelvic tumour sites likely to benefit from this approach.
Collapse
Affiliation(s)
- Ingrid M White
- Institute of Cancer Research and Royal Marsden National Health Service Foundation Trust, Sutton, Surrey, UK
| | - Erica Scurr
- Institute of Cancer Research and Royal Marsden National Health Service Foundation Trust, Sutton, Surrey, UK
| | - Andreas Wetscherek
- Institute of Cancer Research and Royal Marsden National Health Service Foundation Trust, Sutton, Surrey, UK
| | - Gina Brown
- Institute of Cancer Research and Royal Marsden National Health Service Foundation Trust, Sutton, Surrey, UK
| | - Aslam Sohaib
- Institute of Cancer Research and Royal Marsden National Health Service Foundation Trust, Sutton, Surrey, UK
| | - Simeon Nill
- Institute of Cancer Research and Royal Marsden National Health Service Foundation Trust, Sutton, Surrey, UK
| | - Uwe Oelfke
- Institute of Cancer Research and Royal Marsden National Health Service Foundation Trust, Sutton, Surrey, UK
| | - David Dearnaley
- Institute of Cancer Research and Royal Marsden National Health Service Foundation Trust, Sutton, Surrey, UK
| | - Susan Lalondrelle
- Institute of Cancer Research and Royal Marsden National Health Service Foundation Trust, Sutton, Surrey, UK
| | - Shreerang Bhide
- Institute of Cancer Research and Royal Marsden National Health Service Foundation Trust, Sutton, Surrey, UK
| |
Collapse
|
9
|
Tetar SU, Bruynzeel AME, Lagerwaard FJ, Slotman BJ, Bohoudi O, Palacios MA. Clinical implementation of magnetic resonance imaging guided adaptive radiotherapy for localized prostate cancer. PHYSICS & IMAGING IN RADIATION ONCOLOGY 2019; 9:69-76. [PMID: 33458428 PMCID: PMC7807673 DOI: 10.1016/j.phro.2019.02.002] [Citation(s) in RCA: 124] [Impact Index Per Article: 24.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/16/2018] [Revised: 02/13/2019] [Accepted: 02/19/2019] [Indexed: 11/30/2022]
Abstract
Background and purpose Magnetic resonance-guided radiation therapy (MRgRT) has recently become available in clinical practice and is expected to expand significantly in coming years. MRgRT offers marker-less continuous imaging during treatment delivery, use of small clinical target volume (CTV) to planning target volume (PTV) margins, and finally the option to perform daily plan re-optimization. Materials and methods A total of 140 patients (700 fractions) have been treated with MRgRT and online plan adaptation for localized prostate cancer since early 2016. Clinical workflow for MRgRT of prostate cancer consisted of patient selection, simulation on both MR- and computed tomography (CT) scan, inverse intensity-modulated radiotherapy (IMRT) treatment planning and daily plan re-optimization prior to treatment delivery with partial organs at risk (OAR) recontouring within the first 2 cm outside the PTV. For each adapted plan online patient-specific quality assurance (QA) was performed by means of a secondary Monte Carlo 3D dose calculation and gamma analysis comparison. Patient experiences with MRgRT were assessed using a patient-reported outcome questionnaire (PRO-Q) after the last fraction. Results In 97% of fractions, MRgRT was delivered using the online adapted plan. Intrafractional prostate drifts necessitated 2D-corrections during treatment in approximately 20% of fractions. The average duration of an uneventful fraction of MRgRT was 45 min. PRO-Q’s (N = 89) showed that MRgRT was generally well tolerated, with disturbing noise sensations being most commonly reported. Conclusions MRgRT with daily online plan adaptation constitutes an innovative approach for delivering SBRT for prostate cancer and appears to be feasible, although necessitating extended timeslots and logistical challenges.
Collapse
Affiliation(s)
- Shyama U Tetar
- Dept. of Radiation Oncology, VU University Medical Center, de Boelelaan 1117, 1081 HV Amsterdam, The Netherlands
| | - Anna M E Bruynzeel
- Dept. of Radiation Oncology, VU University Medical Center, de Boelelaan 1117, 1081 HV Amsterdam, The Netherlands
| | - Frank J Lagerwaard
- Dept. of Radiation Oncology, VU University Medical Center, de Boelelaan 1117, 1081 HV Amsterdam, The Netherlands
| | - Ben J Slotman
- Dept. of Radiation Oncology, VU University Medical Center, de Boelelaan 1117, 1081 HV Amsterdam, The Netherlands
| | - Omar Bohoudi
- Dept. of Radiation Oncology, VU University Medical Center, de Boelelaan 1117, 1081 HV Amsterdam, The Netherlands
| | - Miguel A Palacios
- Dept. of Radiation Oncology, VU University Medical Center, de Boelelaan 1117, 1081 HV Amsterdam, The Netherlands
| |
Collapse
|
10
|
Hunt A, Hansen VN, Oelfke U, Nill S, Hafeez S. Adaptive Radiotherapy Enabled by MRI Guidance. Clin Oncol (R Coll Radiol) 2018; 30:711-719. [PMID: 30201276 DOI: 10.1016/j.clon.2018.08.001] [Citation(s) in RCA: 79] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2018] [Revised: 08/10/2018] [Accepted: 08/20/2018] [Indexed: 12/11/2022]
Abstract
Adaptive radiotherapy (ART) strategies systematically monitor variations in target and neighbouring structures to inform treatment-plan modification during radiotherapy. This is necessary because a single plan designed before treatment is insufficient to capture the actual dose delivered to the target and adjacent critical structures during the course of radiotherapy. Magnetic resonance imaging (MRI) provides superior soft-tissue image contrast over current standard X-ray-based technologies without additional radiation exposure. With integrated MRI and radiotherapy platforms permitting motion monitoring during treatment delivery, it is possible that adaption can be informed by real-time anatomical imaging. This allows greater treatment accuracy in terms of dose delivered to target with smaller, individualised treatment margins. The use of functional MRI sequences would permit ART to be informed by imaging biomarkers, so allowing both personalised geometric and biological adaption. In this review, we discuss ART solutions enabled by MRI guidance and its potential gains for our patients across tumour types.
Collapse
Affiliation(s)
- A Hunt
- The Institute of Cancer Research, London, UK; The Royal Marsden NHS Foundation Trust, London, UK
| | - V N Hansen
- The Institute of Cancer Research, London, UK; Joint Department of Physics, The Royal Marsden NHS Foundation Trust, London, UK
| | - U Oelfke
- The Institute of Cancer Research, London, UK; Joint Department of Physics, The Royal Marsden NHS Foundation Trust, London, UK
| | - S Nill
- The Institute of Cancer Research, London, UK; Joint Department of Physics, The Royal Marsden NHS Foundation Trust, London, UK
| | - S Hafeez
- The Institute of Cancer Research, London, UK; The Royal Marsden NHS Foundation Trust, London, UK.
| |
Collapse
|
11
|
Pathmanathan AU, van As NJ, Kerkmeijer LGW, Christodouleas J, Lawton CAF, Vesprini D, van der Heide UA, Frank SJ, Nill S, Oelfke U, van Herk M, Li XA, Mittauer K, Ritter M, Choudhury A, Tree AC. Magnetic Resonance Imaging-Guided Adaptive Radiation Therapy: A "Game Changer" for Prostate Treatment? Int J Radiat Oncol Biol Phys 2018; 100:361-373. [PMID: 29353654 DOI: 10.1016/j.ijrobp.2017.10.020] [Citation(s) in RCA: 129] [Impact Index Per Article: 21.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2017] [Revised: 10/09/2017] [Accepted: 10/12/2017] [Indexed: 01/25/2023]
Abstract
Radiation therapy to the prostate involves increasingly sophisticated delivery techniques and changing fractionation schedules. With a low estimated α/β ratio, a larger dose per fraction would be beneficial, with moderate fractionation schedules rapidly becoming a standard of care. The integration of a magnetic resonance imaging (MRI) scanner and linear accelerator allows for accurate soft tissue tracking with the capacity to replan for the anatomy of the day. Extreme hypofractionation schedules become a possibility using the potentially automated steps of autosegmentation, MRI-only workflow, and real-time adaptive planning. The present report reviews the steps involved in hypofractionated adaptive MRI-guided prostate radiation therapy and addresses the challenges for implementation.
Collapse
Affiliation(s)
- Angela U Pathmanathan
- The Institute of Cancer Research, London, United Kingdom; The Royal Marsden National Health Service Foundation Trust, London, United Kingdom
| | - Nicholas J van As
- The Institute of Cancer Research, London, United Kingdom; The Royal Marsden National Health Service Foundation Trust, London, United Kingdom
| | | | | | | | - Danny Vesprini
- Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Uulke A van der Heide
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Steven J Frank
- The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Simeon Nill
- The Institute of Cancer Research, London, United Kingdom; The Royal Marsden National Health Service Foundation Trust, London, United Kingdom
| | - Uwe Oelfke
- The Institute of Cancer Research, London, United Kingdom; The Royal Marsden National Health Service Foundation Trust, London, United Kingdom
| | - Marcel van Herk
- Manchester Cancer Research Centre, University of Manchester, Manchester Academic Health Science Centre, The Christie National Health Service Foundation Trust, Manchester, United Kingdom; National Institute of Health Research, Manchester Biomedical Research Centre, Central Manchester University Hospitals National Health Service Foundation Trust, Manchester Academic Health Science Centre, Manchester, United Kingdom
| | - X Allen Li
- Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Kathryn Mittauer
- University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
| | - Mark Ritter
- University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
| | - Ananya Choudhury
- Manchester Cancer Research Centre, University of Manchester, Manchester Academic Health Science Centre, The Christie National Health Service Foundation Trust, Manchester, United Kingdom; National Institute of Health Research, Manchester Biomedical Research Centre, Central Manchester University Hospitals National Health Service Foundation Trust, Manchester Academic Health Science Centre, Manchester, United Kingdom.
| | - Alison C Tree
- The Institute of Cancer Research, London, United Kingdom; The Royal Marsden National Health Service Foundation Trust, London, United Kingdom
| |
Collapse
|
12
|
Fast and robust online adaptive planning in stereotactic MR-guided adaptive radiation therapy (SMART) for pancreatic cancer. Radiother Oncol 2017; 125:439-444. [PMID: 28811038 DOI: 10.1016/j.radonc.2017.07.028] [Citation(s) in RCA: 242] [Impact Index Per Article: 34.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2017] [Revised: 07/23/2017] [Accepted: 07/27/2017] [Indexed: 02/06/2023]
Abstract
BACKGROUND AND PURPOSE To implement a robust and fast stereotactic MR-guided adaptive radiation therapy (SMART) online strategy in locally advanced pancreatic cancer (LAPC). MATERIAL AND METHODS SMART strategy for plan adaptation was implemented with the MRIdian system (ViewRay Inc.). At each fraction, OAR (re-)contouring is done within a distance of 3cm from the PTV surface. Online plan re-optimization is based on robust prediction of OAR dose and optimization objectives, obtained by building an artificial neural network (ANN). Proposed limited re-contouring strategy for plan adaptation (SMART3CM) is evaluated by comparing 50 previously delivered fractions against a standard (re-)planning method using full-scale OAR (re-)contouring (FULLOAR). Plan quality was assessed using PTV coverage (V95%, Dmean, D1cc) and institutional OAR constraints (e.g. V33Gy). RESULTS SMART3CM required a significant lower number of optimizations than FULLOAR (4 vs 18 on average) to generate a plan meeting all objectives and institutional OAR constraints. PTV coverage with both strategies was identical (mean V95%=89%). Adaptive plans with SMART3CM exhibited significant lower intermediate and high doses to all OARs than FULLOAR, which also failed in 36% of the cases to adhere to the V33Gy dose constraint. CONCLUSIONS SMART3CM approach for LAPC allows good OAR sparing and adequate target coverage while requiring only limited online (re-)contouring from clinicians.
Collapse
|
13
|
McVicar N, Popescu IA, Heath E. Techniques for adaptive prostate radiotherapy. Phys Med 2016; 32:492-8. [DOI: 10.1016/j.ejmp.2016.03.010] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Revised: 02/10/2016] [Accepted: 03/12/2016] [Indexed: 10/22/2022] Open
|