1
|
Probing hair cell's mechano-transduction using two-tone suppression measurements. Sci Rep 2019; 9:4626. [PMID: 30874606 PMCID: PMC6420497 DOI: 10.1038/s41598-019-41112-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2018] [Accepted: 03/01/2019] [Indexed: 11/27/2022] Open
Abstract
When two sound tones are delivered to the cochlea simultaneously, they interact with each other in a suppressive way, a phenomenon referred to as two-tone suppression (2TS). This nonlinear response is ascribed to the saturation of the outer hair cell’s mechano-transduction. Thus, 2TS can be used as a non-invasive probe to investigate the fundamental properties of cochlear mechano-transduction. We developed a nonlinear cochlear model in the time domain to interpret 2TS data. The multi-scale model incorporates cochlear fluid dynamics, organ of Corti (OoC) mechanics and outer hair cell electrophysiology. The model simulations of 2TS show that the threshold amplitudes and rates of low-side suppression are dependent on mechano-transduction properties. By comparing model responses to existing 2TS measurement data, we estimate intrinsic characteristics of mechano-transduction such as sensitivity and adaptation. For mechano-transduction sensitivity at the basal location (characteristic frequency of 17 kHz) at 0.06 nm−1, the simulation results agree with 2TS measurements of basilar membrane responses. This estimate is an order of magnitude higher than the values observed in experiments on isolated outer hair cells. The model also demonstrates how the outer hair cell’s adaptation alters the temporal pattern of 2TS by modulating mechano-electrical gain and phase.
Collapse
|
2
|
Landry TG, Bance ML, Leadbetter J, Adamson RB, Brown JA. In vivo measurement of basilar membrane vibration in the unopened chinchilla cochlea using high frequency ultrasound. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2017; 141:4610. [PMID: 28679279 DOI: 10.1121/1.4985622] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The basilar membrane and organ of Corti in the cochlea are essential for sound detection and frequency discrimination in normal hearing. There are currently no methods used for real-time high resolution clinical imaging or vibrometry of these structures. The ability to perform such imaging could aid in the diagnosis of some pathologies and advance understanding of the causes. It is demonstrated that high frequency ultrasound can be used to measure basilar membrane vibrations through the round window of chinchilla cochleas in vivo. The basic vibration characteristics of the basilar membrane agree with previous studies that used other methods, although as expected, the sensitivity of ultrasound was not as high as optical methods. At the best frequency for the recording location, the average vibration velocity amplitude was about 4 mm/s/Pa with stimulus intensity of 50 dB sound pressure level. The displacement noise floor was about 0.4 nm with 256 trial averages (5.12 ms per trial). Although vibration signals were observed, which likely originated from the organ of Corti, the spatial resolution was not adequate to resolve any of the sub-structures. Improvements to the ultrasound probe design may improve resolution and allow the responses of these different structures to be better discriminated.
Collapse
Affiliation(s)
- Thomas G Landry
- Division of Otolaryngology, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada
| | - Manohar L Bance
- Division of Otolaryngology, Department of Surgery, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Jeffrey Leadbetter
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Robert B Adamson
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Jeremy A Brown
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| |
Collapse
|
3
|
Sieck NE, Rasetshwane DM, Kopun JG, Jesteadt W, Gorga MP, Neely ST. Multi-tone suppression of distortion-product otoacoustic emissions in humans. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2016; 139:2299. [PMID: 27250125 PMCID: PMC4859829 DOI: 10.1121/1.4946989] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2015] [Revised: 03/30/2016] [Accepted: 04/02/2016] [Indexed: 06/05/2023]
Abstract
The purpose of this study was to investigate the combined effect of multiple suppressors. Distortion-product otoacoustic emission (DPOAE) measurements were made in normal-hearing participants. Primary tones had fixed frequencies (f2 = 4000 Hz; f1 / f2 = 1.22) and a range of levels. Suppressor tones were at three frequencies (fs = 2828, 4100, 4300 Hz) and range of levels. Decrement was defined as the attenuation in DPOAE level due to the presence of a suppressor. A measure of suppression called suppressive intensity was calculated by an equation previously shown to fit DPOAE suppression data. Suppressor pairs, which were the combination of two different frequencies, were presented at levels selected to have equal single-suppressor decrements. A hybrid model that represents a continuum between additive intensity and additive attenuation best described the results. The suppressor pair with the smallest frequency ratio produced decrements that were more consistent with additive intensity. The suppressor pair with the largest frequency ratio produced decrements at the highest level that were consistent with additive attenuation. Other suppressor-pair conditions produced decrements that were intermediate between these two alternative models. The hybrid model provides a useful framework for representing the observed range of interaction when two suppressors are combined.
Collapse
Affiliation(s)
- Nicole E Sieck
- Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| | - Daniel M Rasetshwane
- Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| | - Judy G Kopun
- Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| | - Walt Jesteadt
- Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| | - Michael P Gorga
- Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| | - Stephen T Neely
- Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| |
Collapse
|
4
|
Cooper NP, van der Heijden M. Dynamics of Cochlear Nonlinearity. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2016; 894:267-273. [PMID: 27080667 DOI: 10.1007/978-3-319-25474-6_28] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Dynamic aspects of cochlear mechanical compression were studied by recording basilar membrane (BM) vibrations evoked by tone pairs ("beat stimuli") in the 11-19 kHz region of the gerbil cochlea. The frequencies of the stimulus components were varied to produce a range of "beat rates" at or near the characteristic frequency (CF) of the BM site under study, and the amplitudes of the components were balanced to produce near perfect periodic cancellations, visible as sharp notches in the envelope of the BM response. We found a compressive relation between instantaneous stimulus intensity and BM response magnitude that was strongest at low beat rates (e.g., 10-100 Hz). At higher beat rates, the amount of compression reduced progressively (i.e. the responses became linearized), and the rising and falling flanks of the response envelope showed increasing amounts of hysteresis; the rising flank becoming steeper than the falling flank. This hysteresis indicates that cochlear mechanical compression is not instantaneous, and is suggestive of a gain control mechanism having finite attack and release times. In gain control terms, the linearization that occurs at higher beat rates occurs because the instantaneous gain becomes smoothened, or low-pass filtered, with respect to the magnitude fluctuations in the stimulus. In terms of peripheral processing, the linearization corresponds to an enhanced coding, or decompression, of rapid amplitude modulations. These findings are relevant both to those who wish to understand the underlying mechanisms and those who need a realistic model of nonlinear processing by the auditory periphery.
Collapse
|
5
|
Charaziak KK, Siegel JH. Estimating cochlear frequency selectivity with stimulus-frequency otoacoustic emissions in chinchillas. J Assoc Res Otolaryngol 2014; 15:883-96. [PMID: 25230801 DOI: 10.1007/s10162-014-0487-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2014] [Accepted: 09/03/2014] [Indexed: 11/29/2022] Open
Abstract
It has been suggested that the tuning of the cochlear filters can be derived from measures of otoacoustic emissions (OAEs). Two approaches have been proposed to estimate cochlear frequency selectivity using OAEs evoked with a single tone (stimulus-frequency (SF)) OAEs: based on SFOAE group delays (SF-GDs) and on SFOAE suppression tuning curves (SF-STCs). The aim of this study was to evaluate whether either SF-GDs or SF-STCs obtained with low probe levels (30 dB SPL) correlate with more direct measures of cochlear tuning (compound action potential suppression tuning curves (CAP-STCs)) in chinchillas. The SFOAE-based estimates of tuning covaried with CAP-STCs tuning for >3 kHz probe frequencies, indicating that these measures are related to cochlear frequency selectivity. However, the relationship may be too weak to predict tuning with either SFOAE method in an individual. The SF-GD prediction of tuning was sharper than CAP-STC tuning. On the other hand, SF-STCs were consistently broader than CAP-STCs implying that SFOAEs may have less restricted region of generation in the cochlea than CAPs. Inclusion of <3 kHz data in a statistical model resulted in no significant or borderline significant covariation among the three methods: neither SFOAE test appears to reliably estimate an individual's CAP-STC tuning at low-frequencies. At the group level, SF-GDs and CAP-STCs showed similar tuning at low frequencies, while SF-STCs were over five times broader than the CAP-STCs indicating that low-frequency SFOAE may originate over a very broad region of the cochlea extending ≥5 mm basal to the tonotopic place of the probe.
Collapse
Affiliation(s)
- Karolina K Charaziak
- Department of Communication Sciences and Disorders, School of Communication, Northwestern University, 2240 Campus Drive, Evanston, IL, 60208-2952, USA,
| | | |
Collapse
|
6
|
Laback B, Necciari T, Balazs P, Savel S, Ystad S. Simultaneous masking additivity for short Gaussian-shaped tones: spectral effects. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2013; 134:1160-1171. [PMID: 23927115 DOI: 10.1121/1.4812773] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Laback et al. [(2011). J. Acoust. Soc. Am. 129, 888-897] investigated the additivity of nonsimultaneous masking using short Gaussian-shaped tones as maskers and target. The present study involved Gaussian stimuli to measure the additivity of simultaneous masking for combinations of up to four spectrally separated maskers. According to most basilar membrane measurements, the maskers should be processed linearly at the characteristic frequency (CF) of the target. Assuming also compression of the target, all masker combinations should produce excess masking (exceeding linear additivity). The results for a pair of maskers flanking the target indeed showed excess masking. The amount of excess masking could be predicted by a model assuming summation of masker-evoked excitations in intensity units at the target CF and compression of the target, using compressive input/output functions derived from the nonsimultaneous masking study. However, the combinations of lower-frequency maskers showed much less excess masking than predicted by the model. This cannot easily be attributed to factors like off-frequency listening, combination tone perception, or between-masker suppression. It was better predicted, however, by assuming weighted intensity summation of masker excitations. The optimum weights for the lower-frequency maskers were smaller than one, consistent with partial masker compression as indicated by recent psychoacoustic data.
Collapse
Affiliation(s)
- Bernhard Laback
- Acoustics Research Institute, Austrian Academy of Sciences, Wohllebengasse 12-14, A-1040 Vienna, Austria.
| | | | | | | | | |
Collapse
|
7
|
Versteegh CPC, van der Heijden M. The spatial buildup of compression and suppression in the mammalian cochlea. J Assoc Res Otolaryngol 2013; 14:523-45. [PMID: 23690278 PMCID: PMC3705085 DOI: 10.1007/s10162-013-0393-0] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2013] [Accepted: 04/23/2013] [Indexed: 11/25/2022] Open
Abstract
We recorded responses of the gerbil basilar membrane (BM) to wideband tone complexes. The intensity of one component was varied and the effects on the amplitude and phase of the others were assessed. This suppression paradigm enabled us to vary probe frequency and suppressor frequency independently, allowing the use of simple scaling arguments to analyze the spatial buildup of the nonlinear interaction between traveling waves. Most suppressors had the same effects on probe amplitude and phase as did wideband intensity increments. The main exception were suppressors above the characteristic frequency (CF) of the recording location, for which the frequency range of most affected probes was not constant, but shifted upward with suppressor frequency. BM displacement reliably predicted the effectiveness of low-side suppressors, but not high-side suppressors. We found “anti-suppression” of probes well below CF, i.e., suppressor-induced enhancement of probe response amplitude. Large (>1 cycle) phase effects occurred for above-CF probes. Phase shifts varied nonmonotonically, but systematically, with suppressor level, probe frequency, and suppressor frequency, reconciling apparent discrepancies in the literature. The analysis of spatial buildup revealed an accumulation of local effects on the propagation of the traveling wave, with larger BM displacement reducing the local forward gain. The propagation speed of the wave was also affected. With larger BM displacement, the basal portion of the wave slowed down, while the apical part sped up. This framework of spatial buildup of local effects unifies the widely different effects of overall intensity, low-side suppressors, and high-side suppressors on BM responses.
Collapse
|
8
|
Choi YS, Lee SY. Nonlinear spectro-temporal features based on a cochlear model for automatic speech recognition in a noisy situation. Neural Netw 2013; 45:62-9. [PMID: 23558292 DOI: 10.1016/j.neunet.2013.02.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2012] [Revised: 02/20/2013] [Accepted: 02/22/2013] [Indexed: 11/17/2022]
Abstract
A nonlinear speech feature extraction algorithm was developed by modeling human cochlear functions, and demonstrated as a noise-robust front-end for speech recognition systems. The algorithm was based on a model of the Organ of Corti in the human cochlea with such features as such as basilar membrane (BM), outer hair cells (OHCs), and inner hair cells (IHCs). Frequency-dependent nonlinear compression and amplification of OHCs were modeled by lateral inhibition to enhance spectral contrasts. In particular, the compression coefficients had frequency dependency based on the psychoacoustic evidence. Spectral subtraction and temporal adaptation were applied in the time-frame domain. With long-term and short-term adaptation characteristics, these factors remove stationary or slowly varying components and amplify the temporal changes such as onset or offset. The proposed features were evaluated with a noisy speech database and showed better performance than the baseline methods such as mel-frequency cepstral coefficients (MFCCs) and RASTA-PLP in unknown noisy conditions.
Collapse
Affiliation(s)
- Yong-Sun Choi
- Department of Electrical Engineering and Brain Science Research Center, Korea Advanced Institute of Science and Technology, 373-1 Guseong-dong Yuseong-gu, Daejeon 305-701, Republic of Korea
| | | |
Collapse
|
9
|
Recio-Spinoso A, Cooper NP. Masking of sounds by a background noise--cochlear mechanical correlates. J Physiol 2013; 591:2705-21. [PMID: 23478137 DOI: 10.1113/jphysiol.2012.248260] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
In the search for cochlear correlates of auditory masking by noise stimuli, we recorded basilar membrane (BM) vibrations evoked by either tone or click signals in the presence of varying levels of background noise. The BM vibrations were recorded from basal regions in healthy cochleae of anaesthetized chinchilla and gerbil. Non-linear interactions that could underpin various aspects of psychophysical masking data, including both compression and suppression at the BM level, were observed. The suppression effects, whereby the amplitude of the responses to each stimulus component could be reduced, depended on the relative intensities of the noise and the tones or clicks. Only stimulus components whose frequencies fell inside the non-linear region of the recording site, i.e. around its characteristic frequency (CF), were affected by presentation of the 'suppressing' stimulus (which could be either the tone or the noise). Mutual suppression, the simultaneous reduction of the responses to both tones and noise components, was observed under some conditions, but overall reductions of BM vibration were rarely observed. Moderate- to high-intensity tones suppressed BM responses to low-intensity Gaussian stimuli, including both broadband and narrowband noise. Suppression effects were larger for spectral components of the noise response that were closer to the CF. In this regime, the tone and noise stimuli became the suppressor and probe signals, respectively. This study provides the first detailed observations of cochlear mechanical correlates of the masking effects of noise. Mechanical detection thresholds for tone signals, which were arbitrarily defined using three criteria, are shown to increase in almost direct proportion to the noise level for low and moderately high noise levels, in a manner that resembles the findings of numerous psychophysical observations.
Collapse
Affiliation(s)
- Alberto Recio-Spinoso
- Instituto de Investigación en Discapacidades Neurológicas (IDINE), Universidad de Castilla-La Mancha, Almansa 14, 02006 Albacete, Spain.
| | | |
Collapse
|
10
|
Versteegh CPC, van der Heijden M. Basilar membrane responses to tones and tone complexes: nonlinear effects of stimulus intensity. J Assoc Res Otolaryngol 2012; 13:785-98. [PMID: 22935903 PMCID: PMC3505585 DOI: 10.1007/s10162-012-0345-0] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2012] [Accepted: 07/20/2012] [Indexed: 11/27/2022] Open
Abstract
The mammalian inner ear combines spectral analysis of sound with multiband dynamic compression. Cochlear mechanics has mainly been studied using single-tone and tone-pair stimulation. Most natural sounds, however, have wideband spectra. Because the cochlea is strongly nonlinear, wideband responses cannot be predicted by simply adding single-tone responses. We measured responses of the gerbil basilar membrane to single-tone and wideband stimuli and compared them, while focusing on nonlinear aspects of the response. In agreement with previous work, we found that frequency selectivity and its dependence on stimulus intensity were very similar between single-tone and wideband responses. The main difference was a constant shift in effective sound intensity, which was well predicted by a simple gain control scheme. We found expansive nonlinearities in low-frequency responses, which, with increasing frequency, gradually turned into the more familiar compressive nonlinearities. The overall power of distortion products was at least 13 dB below the overall power of the linear response, but in a limited band above the characteristic frequency, the power of distortion products often exceeded the linear response. Our results explain the partial success of a "quasilinear" description of wideband basilar membrane responses, but also indicate its limitations.
Collapse
|
11
|
Rodriguez J, Neely ST. Temporal aspects of suppression in distortion-product otoacoustic emissions. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2011; 129:3082-3089. [PMID: 21568411 PMCID: PMC3108389 DOI: 10.1121/1.3575553] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2011] [Revised: 03/11/2011] [Accepted: 03/15/2011] [Indexed: 05/30/2023]
Abstract
This study examined the time course of cochlear suppression using a tone-burst suppressor to measure decrement of distortion-product otoacoustic emissions (DPOAEs). Seven normal-hearing subjects with ages ranging from 19 to 28 yr participated in the study. Each subject had audiometric thresholds ≤ 15 dB HL [re ANSI (2004) Specifications for Audiometers] for standard octave and inter-octave frequencies from 0.25 to 8 kHz. DPOAEs were elicited by primary tones with f(2) = 4.0 kHz and f(1) = 3.333 kHz (f(2)/f(1) = 1.2). For the f(2), L(2) combination, suppression was measured for three suppressor frequencies: One suppressor below f(2) (3.834 kHz) and two above f(2) (4.166 and 4.282 kHz) at three levels (55, 60, and 65 dB SPL). DPOAE decrement as a function of L(3) for the tone-burst suppressor was similar to decrements obtained with longer duration suppressors. Onset- and setoff- latencies were ≤ 4 ms, in agreement with previous physiological findings in auditory-nerve fiber studies that suggest suppression results from a nearly instantaneous compression of the waveform. Persistence of suppression was absent for the below-frequency suppressor (f(3) = 3.834 kHz) and was ≤ 3 ms for the two above-frequency suppressors (f(3) = 4.166 and 4.282 kHz).
Collapse
Affiliation(s)
- Joyce Rodriguez
- Starkey Hearing Research Center, 2150 Shattuck Avenue, Suite 408, Berkeley, California 94704, USA.
| | | |
Collapse
|
12
|
Yasin I, Plack CJ. The effects of low- and high-frequency suppressors on psychophysical estimates of basilar-membrane compression and gain. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2007; 121:2832-41. [PMID: 17550182 DOI: 10.1121/1.2713675] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Physiological studies suggest that the increase in suppression as a function of suppressor level is greater for a suppressor below than above the signal frequency. This study investigated the pattern of gain reduction underlying this increase in suppression. Temporal masking curves (TMCs) were obtained by measuring the level of a 2.2-kHz sinusoidal off-frequency masker or 4-kHz on-frequency sinusoidal masker required to mask a brief 4-kHz sinusoidal signal at 10 dB SL, for masker-signal intervals of 20-100 ms. TMCs were also obtained in the presence of a 3- or 4.75-kHz sinusoidal suppressor gated with the 4-kHz masker, for suppressor levels of 40-70 dB SPL. The decrease in gain (increase in suppression) as a function of suppressor level was greater with a 3-kHz suppressor than with a 4.75-kHz suppressor, in line with previous findings. Basilar membrane input-output (I/O) functions derived from the TMCs showed a shift to higher input (4-kHz masker) levels of the low-level (linear) portion of the I/O function with the addition of a suppressor, with partial linearization of the function, but no reduction in maximum compression.
Collapse
Affiliation(s)
- Ifat Yasin
- Department of Experimental Psychology, University of Oxford, South Parks Road, Oxford OX1 3UD, United Kingdom.
| | | |
Collapse
|
13
|
Rhode WS. Mutual suppression in the 6 kHz region of sensitive chinchilla cochleae. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2007; 121:2805-18. [PMID: 17550179 DOI: 10.1121/1.2718398] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Basilar membrane (BM) vibration was measured using a displacement measuring interferometer for single-tone and two-tone suppression (2TS) paradigms in the 6-9 kHz region of sensitive chinchilla cochleae that had gains near or better than 60 dB. Based on prior studies of basilar membrane vibration, three significant differences remain between BM and auditory nerve (AN) 2TS responses: (1) suppression thresholds in the tail of tuning curves were much higher in BM than the auditory nerve (AN); (2) rates of suppression were significantly higher in AN than BM; and (3) the amplitude of vibration with low-frequency suppressors was always greater than the single-tone displacement rendering it impossible to explain 2TS rate suppression in the AN. The first two differences are eliminated by the results of the present study while the third remains. Suppression amplitudes greater than 40 dB and rates of suppression larger than 2.5 dB/dB were found for low-frequency suppressors. A correlation between both the gain and nonlinearity of the cochlea and 2TS properties indicates that when sensitive cochleae are studied. The third difference between BM and AN behavior could be strictly a function of the high-pass filter characteristic of the inner hair cells.
Collapse
Affiliation(s)
- William S Rhode
- Department of Physiology, University of Wisconsin, Madison, Wisconsin 53706, USA.
| |
Collapse
|
14
|
Cooper NP. Mechanical preprocessing of amplitude-modulated sounds in the apex of the cochlea. ORL J Otorhinolaryngol Relat Spec 2006; 68:353-8. [PMID: 17065829 DOI: 10.1159/000095281] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Sound-evoked vibrations of individual Hensen's cells in the apical turn of a living guinea pig cochlea were recorded using a displacement-sensitive laser interferometer. The mechanical responses to amplitude-modulated (AM) tones were investigated, and are shown to be physiologically vulnerable. In the healthy cochlea, the AM responses are demodulated strongly at both moderate and high sound pressure levels. In the less healthy and postmortem cochlea, AM demodulation is weaker and is only seen at high stimulus levels. The physiologically vulnerable component of the demodulation is considered to be an analogue of the baseline position shifts that can be seen in the apical cochlea's responses to pure-tone stimuli, and is likely to originate in the cellular motility of the cochlea's outer hair cells.
Collapse
|
15
|
Yasin I, Plack CJ. The role of suppression in the upward spread of masking. J Assoc Res Otolaryngol 2006; 6:368-77. [PMID: 16261268 PMCID: PMC2504625 DOI: 10.1007/s10162-005-0014-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2005] [Accepted: 08/11/2005] [Indexed: 11/29/2022] Open
Abstract
The upward spread of masking refers to the higher growth rate of masking for maskers lower in frequency than the signal, compared to maskers at the signal frequency (Wegel RL, Lane CE. The auditory masking of one pure tone by another and its possible relation to the dynamics of the inner ear. Physics Rev. 23:266-285, 1924; Egan JP, Hake HW. On the masking pattern of a simple auditory stimulus. J. Acoust. Soc. Am. 22:622-630, 1950; Delgutte B. Physiological mechanisms of psychophysical masking: Observations from auditory-nerve fibres. J. Acoust. Soc. Am. 87:791-809, 1990a, Delgutte B. Two-tone rate suppression in auditory-nerve fibres: Dependence on suppressor frequency and level. Hear Res. 49:225-246, 1990b). The upward spread of simultaneous masking may arise from a combination of excitatory and suppressive effects. In this study, growth of masking functions were obtained for a 4-kHz signal masked by an on-frequency (4 kHz) or off-frequency (2.4 kHz), simultaneous or forward masker, in the presence of a notched noise with a center frequency of 4 kHz presented to restrict off-frequency listening. Compression was estimated from the slopes of the off-frequency growth of masking functions. Suppression was estimated by comparing the off-frequency simultaneous- and forward-masked growth of masking functions. Results showed that, for midlevel signals (35-60 dB SPL), the compression exponent estimated from simultaneous and forward masking averaged 0.31 and 0.26, respectively. The maximum amount of suppression (defined as the decrease in the basilar-membrane response to the signal) was variable, ranging from about 6 to 17 dB across subjects. Despite the substantial reduction in the response to the signal, the results suggest that suppression has a minimal effect on the slope of the masking function at mid levels. Rather, upward spread of masking seems to be mainly determined by the compressive basilar-membrane response to the signal in relation to the linear response to the lower-frequency masker.
Collapse
Affiliation(s)
- Ifat Yasin
- Department of Experimental Psychology, University of Oxford, South Parks Road, Oxford, UK.
| | | |
Collapse
|
16
|
Valentine PA, Eggermont JJ. Stimulus dependence of spectro-temporal receptive fields in cat primary auditory cortex. Hear Res 2005; 196:119-33. [PMID: 15464309 DOI: 10.1016/j.heares.2004.05.011] [Citation(s) in RCA: 58] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/24/2004] [Accepted: 05/24/2004] [Indexed: 10/26/2022]
Abstract
The frequency-tuning curve is a static representation of the neuron's sensitivity to stimulus frequency. The temporal aspects of the frequency sensitivity can be captured in the spectro-temporal receptive field (STRF), often presented as the average spectrogram of the stimulus preceding a spike but also as the average frequency-dependent post-stimulus time histogram (PSTH). The temporal envelope of the stimulus produces considerable smoothing, and as a consequence the PSTH representation is finer-grained than the spectrogram representation. Here we compare STRFs for 1/s and 20/s single-frequency stimuli with 120/s steady-state multi-frequency stimuli for 87 recording sites in primary auditory cortex of cats. For the 672 estimated STRFs, which for multi-frequency stimuli were mostly obtained at 55 dB SPL, we found lateral inhibition in 17% of the cases, in 32% post-activation suppression, and in 51% only excitation. In 35% of the recordings the excitatory frequency-tuning curves were very similar for single and multi-frequency stimuli, in the remaining 65% the common finding was the emergence of an intensity independent bandwidth for the multi-frequency stimuli. Comparison of the 20/s and 120/s stimuli showed that the resulting increase in inhibition was strongest in the center of the STRF.
Collapse
Affiliation(s)
- Pamela A Valentine
- Department of Physiology and Biophysics, University of Calgary, Calgary, Alberta, Canada
| | | |
Collapse
|
17
|
Stainsby TH, Moore BCJ, Medland PJ, Glasberg BR. Sequential streaming and effective level differences due to phase-spectrum manipulations. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2004; 115:1665-1673. [PMID: 15101645 DOI: 10.1121/1.1650288] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Roberts et al. [J. Acoust. Soc. Am. 112, 2074-2085 (2002)] demonstrated that sequential stream segregation occurs with stimuli that differ only in phase spectrum. We investigated if this was partly due to differences in effective excitation level. Stimuli were harmonic complexes with a 100 Hz fundamental, 1250-2500 Hz passband, and cosine, alternating, or random component phase. In experiment 1, the complex tones were used as forward maskers of 20-ms probe tones at 1000, 1250, 1650, 2050, 2500, and 3000 Hz. While there was no significant difference in the masking produced by the cosine- and alternating-phase stimuli, the random-phase stimulus produced significantly greater masking, equivalent to a difference in overall effective excitation level of 12.6 dB. Experiments 2 and 3 used the asynchrony detection and subjective streaming tasks of Roberts et al. Successive stimuli had identical phase, but differed in level by 0, 1, 3, 5, 10, or 15 dB. Stream segregation increased once the level difference reached 5 dB. While some of the stream segregation observed by Roberts et al. may have been due to a difference in effective excitation level, this does not account for the stream segregation between cosine- and alternating-phase stimuli.
Collapse
Affiliation(s)
- Thomas H Stainsby
- Department of Experimental Psychology, University of Cambridge, Downing Street, Cambridge CB2 3EB, United Kingdom.
| | | | | | | |
Collapse
|
18
|
Yasin I, Plack CJ. The effects of a high-frequency suppressor on tuning curves and derived basilar-membrane response functions. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2003; 114:322-332. [PMID: 12880044 DOI: 10.1121/1.1579003] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Forward-masked psychophysical tuning curves were obtained using a fixed, low-level signal at a frequency of 4 kHz, and masker frequencies of 2.0, 2.5, 3.0, 3.5, 3.75, 4.0, 4.25, 4.5, 4.75, 5.0, and 5.5 kHz, at masker-signal gaps of 20, 30, 40, 60, 80, and 100 ms. An adaptive two-interval, two alternative forced-choice (21-2AFC) procedure was used to obtain the masker level at threshold. This procedure was repeated with the addition of a 4.75-kHz suppressor at 50 or 60 dB SPL, gated with the masker. Tuning curves were broader, and estimates of compression and gain from derived input/output functions were decreased in the presence of a suppressor as compared to the no-suppressor condition. The results are consistent with physiological results, which show that suppression leads to a broadening of tuning curves and a partial linearization of the midlevel portion of the basilar-membrane input/output function.
Collapse
Affiliation(s)
- Ifat Yasin
- Department of Psychology, University of Essex, Wivenhoe Park, Colchester CO4 3SQ, England.
| | | |
Collapse
|