Ostras O, Shponka I, Pinton G. Ultrasound imaging of lung disease and its relationship to histopathology: An experimentally validated simulation approach. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2023; 154:2410-2425. [PMID: 37850835 PMCID: PMC10586875 DOI: 10.1121/10.0021870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Revised: 09/23/2023] [Accepted: 09/26/2023] [Indexed: 10/19/2023]
Abstract
Lung ultrasound (LUS) is a widely used technique in clinical lung assessment, yet the relationship between LUS images and the underlying disease remains poorly understood due in part to the complexity of the wave propagation physics in complex tissue/air structures. Establishing a clear link between visual patterns in ultrasound images and underlying lung anatomy could improve the diagnostic accuracy and clinical deployment of LUS. Reverberation that occurs at the lung interface is complex, resulting in images that require interpretation of the artifacts deep in the lungs. These images are not accurate spatial representations of the anatomy due to the almost total reflectivity and high impedance mismatch between aerated lung and chest wall. Here, we develop an approach based on the first principles of wave propagation physics in highly realistic maps of the human chest wall and lung to unveil a relationship between lung disease, tissue structure, and its resulting effects on ultrasound images. It is shown that Fullwave numerical simulations of ultrasound propagation and histology-derived acoustical maps model the multiple scattering physics at the lung interface and reproduce LUS B-mode images that are comparable to clinical images. However, unlike clinical imaging, the underlying tissue structure model is known and controllable. The amount of fluid and connective tissue components in the lung were gradually modified to model disease progression, and the resulting changes in B-mode images and non-imaging reverberation measures were analyzed to explain the relationship between pathological modifications of lung tissue and observed LUS.
Collapse
Affiliation(s)
- Oleksii Ostras
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, North Carolina 27514, USA
| | - Ihor Shponka
- Department of Pathology and Forensic Medicine, Dnipro State Medical University, Dnipro, Ukraine
| | - Gianmarco Pinton
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, North Carolina 27514, USA
| |
Collapse
|
2
|
Liu D, Adams MS, Diederich CJ. Endobronchial high-intensity ultrasound for thermal therapy of pulmonary malignancies: simulations with patient-specific lung models. Int J Hyperthermia 2019; 36:1108-1121. [PMID: 31726895 DOI: 10.1080/02656736.2019.1683234] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
Objective: This study investigates the feasibility of endobronchial ultrasound applicators for thermal ablation of lung tumors using acoustic and biothermal simulations.Methods: Endobronchial ultrasound applicators with planar (10 mm width) or tubular transducers (6 mm outer diameter (OD)) encapsulated by expandable coupling balloons (10 mm OD) are considered for treating tumors from within major airways; smaller catheter-based applicators with tubular transducers (1.7-4 mm OD) and coupling balloons (2.5-5 mm OD) are considered within deep lung airways. Parametric studies were applied to evaluate transducer configurations, tumor size and location, effects of acoustic reflection and absorption at tumor-lung parenchyma interfaces, and the utility of lung flooding for enhancing accessibility. Patient-specific anatomical lung models, with various geometries and locations of tumors, were developed for further evaluation of device performance and treatment strategies. Temperature and thermal dose distributions were calculated and reported.Results: Large endobronchial applicators with planar or tubular transducers (3-7 MHz, 5 min) can thermally ablate tumors attached to major bronchi at up to 3 cm depth, where reflection and attenuation of normal lung localize tumor heating; with lung flooding, endobronchial applicators can ablate ∼2 cm diameter tumors with up to ∼2 cm separation from the bronchial wall, without significant heating of intervening tissue. Smaller catheter-based tubular applicators can ablate tumors up to 2-3 cm in diameter from deep lung airways (5-9 MHz, 5 min).Conclusion: Simulations demonstrate the feasibility of endobronchial ultrasound applicators to deliver thermal coagulation of 2-3 cm diameter tumors adjacent to or accessible from major and deep lung airways.
Collapse
Affiliation(s)
- Dong Liu
- Department of Radiation Oncology, University of California San Francisco, San Francisco, CA, USA
| | - Matthew S Adams
- Department of Radiation Oncology, University of California San Francisco, San Francisco, CA, USA
| | - Chris J Diederich
- Department of Radiation Oncology, University of California San Francisco, San Francisco, CA, USA
| |
Collapse
|
3
|
Miller DL. Mechanisms for Induction of Pulmonary Capillary Hemorrhage by Diagnostic Ultrasound: Review and Consideration of Acoustical Radiation Surface Pressure. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:2743-2757. [PMID: 27649878 PMCID: PMC5116429 DOI: 10.1016/j.ultrasmedbio.2016.08.006] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2016] [Revised: 07/22/2016] [Accepted: 08/02/2016] [Indexed: 05/03/2023]
Abstract
Diagnostic ultrasound can induce pulmonary capillary hemorrhage (PCH) in rats and other mammals. This phenomenon represents the only clearly demonstrated biological effect of (non-contrast enhanced) diagnostic ultrasound and thus presents a uniquely important safety issue. However, the physical mechanism responsible for PCH remains uncertain more than 25 y after its discovery. Experimental research has indicated that neither heating nor acoustic cavitation, the predominant mechanisms for bioeffects of ultrasound, is responsible for PCH. Furthermore, proposed theoretical mechanisms based on gas-body activation, on alveolar resonance and on impulsive generation of liquid droplets all appear unlikely to be responsible for PCH, owing to unrealistic model assumptions. Here, a simple model based on the acoustical radiation surface pressure (ARSP) at a tissue-air interface is hypothesized as the mechanism for PCH. The ARSP model seems to explain some features of PCH, including the approximate frequency independence of PCH thresholds and the dependence of thresholds on biological factors. However, ARSP evaluated for experimental threshold conditions appear to be too weak to fully account for stress failure of pulmonary capillaries, gauging by known stresses for injurious physiologic conditions. Furthermore, consideration of bulk properties of lung tissue suggests substantial transmission of ultrasound through the pleura, with reduced ARSP and potential involvement of additional mechanisms within the pulmonary interior. Although these recent findings advance our knowledge, only a full understanding of PCH mechanisms will allow development of science-based safety assurance for pulmonary ultrasound.
Collapse
Affiliation(s)
- Douglas L Miller
- Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA.
| |
Collapse
|
4
|
Soldati G, Inchingolo R, Smargiassi A, Sher S, Nenna R, Inchingolo CD, Valente S. Ex vivo lung sonography: morphologic-ultrasound relationship. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:1169-1179. [PMID: 22579543 DOI: 10.1016/j.ultrasmedbio.2012.03.001] [Citation(s) in RCA: 77] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2011] [Revised: 03/01/2012] [Accepted: 03/02/2012] [Indexed: 05/31/2023]
Abstract
Ultrasound (US) interstitial syndrome is a sonographic lung pattern characterized by the presence of acoustic artifacts (B-lines and white lung). The purpose of this study was to demonstrate how interstitial syndrome is determined by acoustic interactions in lungs of variable density and in healthy organs deflated to a nonphysiologic level of density. Normal rabbit lungs were studied ex vivo by US at varying known degrees of inflation, and their histologic appearances were described. In this experimental setting, US interstitial syndrome recognizes a mechanism related to tissue density or porosity. Artifacts (B-lines and white lung) appear in the normal rabbit lung through air-dependent increases in density. As in pathologic conditions, US interstitial syndrome can be reproduced in histologically normal lungs that are deflated to a critical level (>0.45 g/mL) of density, which is not achievable under physiologic conditions.
Collapse
Affiliation(s)
- Gino Soldati
- Emergency Department, Valle del Serchio General Hospital, Lucca, Italy
| | | | | | | | | | | | | |
Collapse
|
5
|
Soldati G, Giunta V, Sher S, Melosi F, Dini C. "Synthetic" comets: a new look at lung sonography. ULTRASOUND IN MEDICINE & BIOLOGY 2011; 37:1762-1770. [PMID: 21924815 DOI: 10.1016/j.ultrasmedbio.2011.05.024] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2011] [Revised: 05/19/2011] [Accepted: 05/20/2011] [Indexed: 05/31/2023]
Abstract
Ultrasound interstitial syndrome is an echographic pattern of the lung characterized by the presence of multiple acoustic artifacts called "comets" or B-lines. It correlates to increase in extravascular lung water and to interstitial lung disease. From the physical and genetic point of view, the characteristics and the entity of this correlation have not yet been studied. The purpose of this study was to extrapolate past observations and demonstrate how comets or B-lines are artifactual images whose formation is linked to ultrasound interactions on discretely aerated tissues of variable density. Echographic comets were studied by scanning a wet synthetic, partially aerated polyurethane sponge (phantom). Density of the phantom in different drying phases was measured and correlated to the presence of echographic artifacts. Artifacts (comets) showed a different concentration from a completely white artifactual field to presence of rare comets. Their density correlates with porosity and geometry of the phantom. In our opinion, comets represent superficial, artifactual, density and geometry correlated phenomenon due to the acoustic permeability of a broken (collapsed) specular reflector, normally present when the phantom is dry.
Collapse
Affiliation(s)
- Gino Soldati
- Emergency Medicine Unit, Valle del Serchio General Hospital, Lucca, Italy.
| | | | | | | | | |
Collapse
|
6
|
Abstract
Ultrasound is a relatively inexpensive, portable, and versatile imaging modality that has a broad range of clinical uses. It incorporates many imaging modes, such as conventional gray-scale "B-mode" imaging to display echo amplitude in a scanned plane; M-mode imaging to track motion at a given fixed location over time; duplex, color, and power Doppler imaging to display motion in a scanned plane; harmonic imaging to display nonlinear responses to incident ultrasound; elastographic imaging to display relative tissue stiffness; and contrast-agent imaging with simple contrast agents to display blood-filled spaces or with targeted agents to display specific agent-binding tissue types. These imaging modes have been well described in the scientific, engineering, and clinical literature. A less well-known ultrasonic imaging technology is based on quantitative ultrasound (QUS), which analyzes the distribution of power as a function of frequency in the original received echo signals from tissue and exploits the resulting spectral parameters to characterize and distinguish among tissues. This article discusses the attributes of QUS-based methods for imaging cancers and providing improved means of detecting and assessing tumors. The discussion will include applications to imaging primary prostate cancer and metastatic cancer in lymph nodes to illustrate the methods.
Collapse
Affiliation(s)
- Ernest J Feleppa
- Lizzi Center for Biomedical Engineering, Riverside Research Institute, New York, NY 10038, USA.
| | | | | | | |
Collapse
|
7
|
Mamou J, Coron A, Hata M, Machi J, Yanagihara E, Laugier P, Feleppa EJ. Three-dimensional high-frequency characterization of cancerous lymph nodes. ULTRASOUND IN MEDICINE & BIOLOGY 2010; 36:361-75. [PMID: 20133046 PMCID: PMC2826510 DOI: 10.1016/j.ultrasmedbio.2009.10.007] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2009] [Revised: 09/29/2009] [Accepted: 10/12/2009] [Indexed: 05/05/2023]
Abstract
High-frequency ultrasound (HFU) offers a means of investigating biologic tissue at the microscopic level. High-frequency, three-dimensional (3-D) quantitative-ultrasound (QUS) methods were developed to characterize freshly-dissected lymph nodes of cancer patients. Three-dimensional ultrasound data were acquired from lymph nodes using a 25.6-MHz center-frequency transducer. Each node was inked prior to tissue fixation to recover orientation after sectioning for 3-D histologic evaluation. Backscattered echo signals were processed using 3-D cylindrical regions-of-interest to yield four QUS estimates associated with tissue microstructure (i.e., effective scatterer size, acoustic concentration, intercept and slope). QUS estimates were computed following established methods using two scattering models. In this study, 46 lymph nodes acquired from 27 patients diagnosed with colon cancer were processed. Results revealed that fully-metastatic nodes could be perfectly differentiated from cancer-free nodes using slope or scatterer-size estimates. Specifically, results indicated that metastatic nodes had an average effective scatterer size (i.e., 37.1 +/- 1.7 microm) significantly larger (p < 0.05) than that in cancer-free nodes (i.e., 26 +/- 3.3 microm). Therefore, the 3-D QUS methods could provide a useful means of identifying small metastatic foci in dissected lymph nodes that might not be detectable using current standard pathology procedures.
Collapse
Affiliation(s)
- Jonathan Mamou
- F L Lizzi Center for Biomedical Engineering, Riverside Research Institute, New York, NY 10038, USA.
| | | | | | | | | | | | | |
Collapse
|
8
|
Oelze ML, Miller RJ, Blue JP, Zachary JF, O'Brien WD. Estimation of the acoustic impedance of lung versus level of inflation for different species and ages of animals. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2008; 124:2340-52. [PMID: 19062872 PMCID: PMC2677343 DOI: 10.1121/1.2973186] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
In a previous study, it was hypothesized that ultrasound-induced lung damage was related to the transfer of ultrasonic energy into the lungs (W. D. O'Brien et al. 2002, "Ultrasound-induced lung hemorrhage: Role of acoustic boundary conditions at the pleural surface," J. Acoust. Soc. Am. 111, 1102-1109). From this study a technique was developed to: 1) estimate the impedance (Mrayl) of fresh, excised, ex vivo rat lung versus its level of inflation (cm H(2)O) and 2) predict the fraction of ultrasonic energy transmitted into the lung (M. Oelze et al. 2003, "Impedance measurements of ex vivo rat lung at different volumes of inflation." J. Acoust. Soc. Am. 114, 3384-3393). In the current study, the same technique was used to estimate the frequency-dependent impedance of lungs from rats, rabbits, and pigs of various ages. Impedance values were estimated from lungs under deflation (atmospheric pressure, 0 cm H(2)O) and three volumes of inflation pressure [7 cm H(2)O (5 cm H(2)O for pigs), 10 cm H(2)O, and 15 cm H(2)O]. Lungs were scanned in a tank of degassed 37 degrees C water. The frequency-dependent acoustic pressure reflection coefficient was determined over a frequency range of 3.5-10 MHz. From the reflection coefficient, the frequency-dependent lung impedance was calculated with values ranging from an average of 1.4 Mrayl in deflated lungs (atmospheric pressure) to 0.1 Mrayl for fully inflated lungs (15 cm H(2)O). Across all species, deflated lung (i.e., approximately 7% of the total lung capacity) had impedance values closer to tissue values, suggesting that more acoustic energy was transmitted into the lung under deflated conditions. Finally, the impedance values of deflated lungs from different species at different ages were compared with the thresholds for ultrasound-induced lung damage. The comparison revealed that increases in ultrasonic energy transmission corresponded to lower injury threshold values.
Collapse
Affiliation(s)
- Michael L Oelze
- Bioacoustics Research Laboratory, Department of Electrical and Computer Engineering, University of Illinois, 405 North Mathews, Urbana, Illinois 61801, USA.
| | | | | | | | | |
Collapse
|
9
|
Torno MD, Kaminski MD, Xie Y, Meyers RE, Mertz CJ, Liu X, O'Brien WD, Rosengart AJ. Improvement of in vitro thrombolysis employing magnetically-guided microspheres. Thromb Res 2007; 121:799-811. [PMID: 17942144 DOI: 10.1016/j.thromres.2007.08.017] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2007] [Revised: 08/03/2007] [Accepted: 08/24/2007] [Indexed: 11/19/2022]
Abstract
Significant shortcomings in clinical thrombolysis efficiencies and arterial recanalization rates still exist to date necessitating the development of additional thrombolysis-enhancing technologies. For example, to improve tPA-induced systemic clot lysis several supplementary treatment methods have been proposed, among them ultrasound-enhanced tissue plasminogen activator (tPA) thrombolysis which has already found some clinical applicability. The rationale of this study was to investigate whether biodegradable, magnetic spheres can be a useful adjuvant to currently existing tPA-induced thrombolysis and further enhance clot lysis results. Based on an envisioned, novel thrombolysis technology--magnetically-guided, tPA-loaded nanocarriers with triggered release of the shielded drug at an intravascular target site--we evaluated the lysis efficiencies of magnetically-guided, non-medicated magnetic spheres in various combinations with tPA and ultrasound. When tPA was used in conjunction with magnetic spheres and a magnetic field, the lysis efficiency under static, no-flow conditions improved by 1.7 and 2.7 fold for red and white clots, respectively. In dynamic lysis studies, the addition of ultrasound and magnetically-guided spheres to lytic tPA dosages resulted in both maximum clot lysis efficiency and shortest reperfusion time corresponding to a 2-fold increase in lysis and 7-fold reduction in recanalization time, respectively. Serial microscopic evaluations on histochemical sections reconfirmed that tPA penetration into and fragmentation of the clot increased with escalating exposure time to tPA and magnetic spheres/field. These results delineate the effectiveness of magnetic spheres as an adjuvant to tPA therapy accelerating in vitro lysis efficiencies beyond values found for tPA with and without ultrasound. We demonstrated that the supplementary use of magnetically-guided, non-medicated magnetic spheres significantly enhances in vitro static and dynamic lysis of red and white blood clots.
Collapse
Affiliation(s)
- Michael D Torno
- Neurocritical Care and Acute Stroke Section, Department of Neurology, The University of Chicago Medical Center, Chicago, IL 60637, USA
| | | | | | | | | | | | | | | |
Collapse
|
10
|
Zachary JF, Blue JP, Miller RJ, Ricconi BJ, Eden JG, O'Brien WD. Lesions of ultrasound-induced lung hemorrhage are not consistent with thermal injury. ULTRASOUND IN MEDICINE & BIOLOGY 2006; 32:1763-70. [PMID: 17112962 PMCID: PMC1994783 DOI: 10.1016/j.ultrasmedbio.2006.06.012] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2006] [Revised: 06/01/2006] [Accepted: 06/08/2006] [Indexed: 05/08/2023]
Abstract
Thermal injury, a potential mechanism of ultrasound-induced lung hemorrhage, was studied by comparing lesions induced by an infrared laser (a tissue-heating source) with those induced by pulsed ultrasound. A 600-mW continuous-wave CO2 laser (wavelength approximately 10.6 microm) was focused (680-microm beamwidth) on the surface of the lungs of rats for a duration between 10 to 40 s; ultrasound beamwidths were between 310 and 930 microm. After exposure, lungs were examined grossly and then processed for microscopic evaluation. Grossly, lesions induced by laser were somewhat similar to those induced by ultrasound; however, microscopically, they were dissimilar. Grossly, lesions were oval, red to dark red and extended into subjacent tissue to form a cone. The surface was elevated, but the center of the laser-induced lesions was often depressed. Microscopically, the laser-induced injury consisted of coagulation of tissue, cells and fluids, whereas injury induced by ultrasound consisted solely of alveolar hemorrhage. These results suggest that ultrasound-induced lung injury is most likely not caused by a thermal mechanism.
Collapse
Affiliation(s)
- James F Zachary
- Department of Pathobiology, College of Veterinary Medicine, University of Illinois at Urbana-Champaign, Urbana, IL 61802, USA.
| | | | | | | | | | | |