1
|
Carney LH. Neural Fluctuation Contrast as a Code for Complex Sounds: The Role and Control of Peripheral Nonlinearities. Hear Res 2024; 443:108966. [PMID: 38310710 PMCID: PMC10923127 DOI: 10.1016/j.heares.2024.108966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 01/14/2024] [Accepted: 01/26/2024] [Indexed: 02/06/2024]
Abstract
The nonlinearities of the inner ear are often considered to be obstacles that the central nervous system has to overcome to decode neural responses to sounds. This review describes how peripheral nonlinearities, such as saturation of the inner-hair-cell response and of the IHC-auditory-nerve synapse, are instead beneficial to the neural encoding of complex sounds such as speech. These nonlinearities set up contrast in the depth of neural-fluctuations in auditory-nerve responses along the tonotopic axis, referred to here as neural fluctuation contrast (NFC). Physiological support for the NFC coding hypothesis is reviewed, and predictions of several psychophysical phenomena, including masked detection and speech intelligibility, are presented. Lastly, a framework based on the NFC code for understanding how the medial olivocochlear (MOC) efferent system contributes to the coding of complex sounds is presented. By modulating cochlear gain control in response to both sound energy and fluctuations in neural responses, the MOC system is hypothesized to function not as a simple feedback gain-control device, but rather as a mechanism for enhancing NFC along the tonotopic axis, enabling robust encoding of complex sounds across a wide range of sound levels and in the presence of background noise. Effects of sensorineural hearing loss on the NFC code and on the MOC feedback system are presented and discussed.
Collapse
Affiliation(s)
- Laurel H Carney
- Depts. of Biomedical Engineering, Neuroscience, and Electrical & Computer Engineering University of Rochester, Rochester, NY, USA.
| |
Collapse
|
2
|
Salloom WB, Strickland EA. The effect of broadband elicitor laterality on psychoacoustic gain reduction across signal frequency. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 150:2817. [PMID: 34717476 PMCID: PMC8520488 DOI: 10.1121/10.0006662] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 09/17/2021] [Accepted: 09/21/2021] [Indexed: 05/19/2023]
Abstract
There are psychoacoustic methods thought to measure gain reduction, which may be from the medial olivocochlear reflex (MOCR), a bilateral feedback loop that adjusts cochlear gain. Although studies have used ipsilateral and contralateral elicitors and have examined strength at different signal frequencies, these factors have not been examined within a single study. Therefore, basic questions about gain reduction, such as the relative strength of ipsilateral vs contralateral elicitation and the relative strength across signal frequency, are not known. In the current study, gain reduction from ipsilateral, contralateral, and bilateral elicitors was measured at 1-, 2-, and 4-kHz signal frequencies using forward masking paradigms at a range of elicitor levels in a repeated measures design. Ipsilateral and bilateral strengths were similar and significantly larger than contralateral strength across signal frequencies. Growth of gain reduction with precursor level tended to differ with signal frequency, although not significantly. Data from previous studies are considered in light of the results of this study. Behavioral results are also considered relative to anatomical and physiological data on the MOCR. These results indicate that, in humans, cochlear gain reduction is broad across frequencies and is robust for ipsilateral and bilateral elicitation but small for contralateral elicitation.
Collapse
Affiliation(s)
- William B Salloom
- Department of Speech, Language, and Hearing Sciences, Purdue University, 715 Clinic Drive, West Lafayette, Indiana 47907, USA
| | - Elizabeth A Strickland
- Department of Speech, Language, and Hearing Sciences, Purdue University, 715 Clinic Drive, West Lafayette, Indiana 47907, USA
| |
Collapse
|
3
|
Jennings SG. The role of the medial olivocochlear reflex in psychophysical masking and intensity resolution in humans: a review. J Neurophysiol 2021; 125:2279-2308. [PMID: 33909513 PMCID: PMC8285664 DOI: 10.1152/jn.00672.2020] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Revised: 03/16/2021] [Accepted: 04/02/2021] [Indexed: 02/01/2023] Open
Abstract
This review addresses the putative role of the medial olivocochlear (MOC) reflex in psychophysical masking and intensity resolution in humans. A framework for interpreting psychophysical results in terms of the expected influence of the MOC reflex is introduced. This framework is used to review the effects of a precursor or contralateral acoustic stimulation on 1) simultaneous masking of brief tones, 2) behavioral estimates of cochlear gain and frequency resolution in forward masking, 3) the buildup and decay of forward masking, and 4) measures of intensity resolution. Support, or lack thereof, for a role of the MOC reflex in psychophysical perception is discussed in terms of studies on estimates of MOC strength from otoacoustic emissions and the effects of resection of the olivocochlear bundle in patients with vestibular neurectomy. Novel, innovative approaches are needed to resolve the dissatisfying conclusion that current results are unable to definitively confirm or refute the role of the MOC reflex in masking and intensity resolution.
Collapse
Affiliation(s)
- Skyler G Jennings
- Department of Communication Sciences and Disorders, The University of Utah, Salt Lake City, Utah
| |
Collapse
|
4
|
Jennings SG, Chen J. Masking of short tones in noise: Evidence for envelope-based, rather than energy-based detection. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 148:211. [PMID: 32752781 PMCID: PMC7363451 DOI: 10.1121/10.0001569] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2019] [Revised: 06/09/2020] [Accepted: 06/23/2020] [Indexed: 06/01/2023]
Abstract
The "temporal effect" in simultaneous masking may be characterized by better probe detection thresholds for a short, tonal probe presented at the temporal center of a masker compared to at the onset of a masker. Energy-based models of masking have been used to interpret the temporal effect as evidence that the gain of the auditory system decreases during acoustic stimulation. This study shows that masking from temporal-envelope fluctuations of a precursor or from a temporal gap between stimuli violates the assumptions of energy-based models and complicates the interpretation of temporal effects in terms of a reduction in gain. Detection thresholds were measured for a 6-ms, 4000-Hz probe preceded by a narrowband precursor and presented 2-, 197-, or 392-ms after the onset of a narrowband masker. The delay between the precursor offset and masker onset ranged from -2 to 250 ms. Probe thresholds were elevated in the presence of precursors with fluctuating compared to flattened temporal envelopes and when a temporal gap was inserted between the precursor and masker. The results suggest that the interpretation and design of temporal-effect studies should consider the masking effects of temporal-envelope fluctuations. These findings are consistent with speech-perception experiments that show masking from temporal-envelope fluctuations.
Collapse
Affiliation(s)
- Skyler G Jennings
- Department of Communication Sciences and Disorders, The University of Utah, 390 South, 1530 East, Behavioral Sciences Building 1201, Salt Lake City, Utah 84112, USA
| | - Jessica Chen
- Department of Communication Sciences and Disorders, The University of Utah, 390 South, 1530 East, Behavioral Sciences Building 1201, Salt Lake City, Utah 84112, USA
| |
Collapse
|
5
|
Exploring the Role of Medial Olivocochlear Efferents on the Detection of Amplitude Modulation for Tones Presented in Noise. J Assoc Res Otolaryngol 2019; 20:395-413. [PMID: 31140010 PMCID: PMC6646499 DOI: 10.1007/s10162-019-00722-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Accepted: 04/15/2019] [Indexed: 10/26/2022] Open
Abstract
The medial olivocochlear reflex has been hypothesized to improve the detection and discrimination of dynamic signals in noisy backgrounds. This hypothesis was tested here by comparing behavioral outcomes with otoacoustic emissions. The effects of a precursor on amplitude-modulation (AM) detection were measured for a 1- and 6-kHz carrier at levels of 40, 60, and 80 dB SPL in a two-octave-wide noise masker with a level designed to produce poor, but above-chance, performance. Three types of precursor were used: a two-octave noise band, an inharmonic complex tone, and a pure tone. Precursors had the same overall level as the simultaneous noise masker that immediately followed the precursor. The noise precursor produced a large improvement in AM detection for both carrier frequencies and at all three levels. The complex tone produced a similarly large improvement in AM detection at the highest level but had a smaller effect for the two lower carrier levels. The tonal precursor did not significantly affect AM detection in noise. Comparisons of behavioral thresholds and medial olivocochlear efferent effects on stimulus frequency otoacoustic emissions measured with similar stimuli did not support the hypothesis that efferent-based reduction of cochlear responses contributes to the precursor effects on AM detection.
Collapse
|
6
|
Partial loudness at masker onset indicates temporal effects at supra-threshold levels. Hear Res 2018; 370:168-180. [PMID: 30390569 DOI: 10.1016/j.heares.2018.10.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2018] [Revised: 10/12/2018] [Accepted: 10/17/2018] [Indexed: 11/23/2022]
Abstract
This study examines temporal effects both at threshold and at supra-threshold levels. The level needed to detect a short-duration 4.0-kHz signal was measured for signals presented with different onset delays relative to a 300-ms broadband noise masker: 100 ms and 5 ms before the onset of the masker and 5 ms and 100 ms after the onset of the masker. Loudness matches between the signal in quiet and the signal at the same four onset delays were obtained for five presentation levels of the short-duration signal and for three masker levels. The temporal effect was defined as the level difference between the signals near masker onset and the signals well before or well after masker onset, needed to reach threshold and/or achieve equal loudness. Both at threshold and at supra-threshold levels temporal effects were observed consistent with a decrease in gain at the masker frequency during the course of the masker. The temporal effect was not restricted to simultaneous masking, but was also found for backward masking. In both cases the temporal effects were stronger at supra-threshold levels than at threshold. This may be caused by a transient effect at masker onset. The almost simultaneous onset of the signal and the masker makes it difficult for subjects to separate signal from the masker, especially when the signal level is close to masked threshold.
Collapse
|
7
|
Jennings SG, Sivas K, Stone C. Effects of Masker Envelope Fluctuations on the Temporal Effect. J Assoc Res Otolaryngol 2018; 19:717-727. [PMID: 30128623 DOI: 10.1007/s10162-018-00688-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2017] [Accepted: 06/26/2018] [Indexed: 11/25/2022] Open
Abstract
Under certain conditions, detection thresholds in simultaneous masking improve when the onset of a short sinusoidal probe is delayed from the onset of a long masker. This improvement, known as the temporal effect, is largest for broadband maskers and is smaller or absent for narrowband maskers centered on the probe frequency. This study tests the hypothesis that small or absent temporal effects for narrowband maskers are due to the inherent temporal envelope fluctuations of Gaussian noise. Temporal effects were measured for narrowband noise maskers with fluctuating ("fluctuating maskers") and flattened ("flattened maskers") temporal envelopes as a function of masker level (Exp. I) and in the presence of fluctuating and flattened precursors (Exp. II). The temporal effect was absent for fluctuating narrowband maskers and as large as ~ 7 dB for flattened narrowband maskers. The AC-coupled power of the temporal envelopes of precursors and maskers accounted for 94 % of the variance in probe detection thresholds measured with fluctuating and flattened precursors and maskers. These results suggest that masker temporal envelope fluctuations contribute to the temporal effect and should be considered in future modeling efforts.
Collapse
Affiliation(s)
- Skyler G Jennings
- Department of Communication Sciences and Disorders, The University of Utah, 390 South, 1530 East, BEHS 1201, Salt Lake City, UT, 84112, USA. .,Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, 135 Rutledge Avenue, MSC 550, Charleston, SC, 29425-5500, USA.
| | - Kayla Sivas
- Department of Communication Sciences and Disorders, The University of Utah, 390 South, 1530 East, BEHS 1201, Salt Lake City, UT, 84112, USA
| | - Caitlin Stone
- Department of Communication Sciences and Disorders, The University of Utah, 390 South, 1530 East, BEHS 1201, Salt Lake City, UT, 84112, USA
| |
Collapse
|
8
|
DeRoy Milvae K, Strickland EA. Psychoacoustic measurements of ipsilateral cochlear gain reduction as a function of signal frequency. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 143:3114. [PMID: 29857720 PMCID: PMC5967972 DOI: 10.1121/1.5038254] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2017] [Revised: 03/09/2018] [Accepted: 04/30/2018] [Indexed: 05/19/2023]
Abstract
Forward masking experiments at 4 kHz have demonstrated that preceding sound can elicit changes in masking patterns consistent with a change in cochlear gain. However, the acoustic environment is filled with complex sounds, often dominated by lower frequencies, and ipsilateral cochlear gain reduction at frequencies below 4 kHz is largely unstudied in the forward masking literature. In this experiment, the magnitude of ipsilateral cochlear gain reduction was explored at 1, 2, and 4 kHz using forward masking techniques in an effort to evaluate a range of frequencies in listeners with normal hearing. Gain reduction estimates were not significantly different at 2 and 4 kHz using two forward masking measurements. Although the frequency was a significant factor in the analysis, post hoc testing supported the interpretation that gain reduction estimates measured without a masker were not significantly different at 1, 2, and 4 kHz. A second experiment provided evidence that forward masking in this paradigm at 1 kHz cannot be explained by excitation alone. This study provides evidence of ipsilateral cochlear gain reduction in humans at frequencies below the 4 kHz region.
Collapse
Affiliation(s)
- Kristina DeRoy Milvae
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907, USA
| | - Elizabeth A Strickland
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907, USA
| |
Collapse
|
9
|
Lopez-Poveda EA. Olivocochlear Efferents in Animals and Humans: From Anatomy to Clinical Relevance. Front Neurol 2018; 9:197. [PMID: 29632514 PMCID: PMC5879449 DOI: 10.3389/fneur.2018.00197] [Citation(s) in RCA: 81] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2018] [Accepted: 03/13/2018] [Indexed: 11/13/2022] Open
Abstract
Olivocochlear efferents allow the central auditory system to adjust the functioning of the inner ear during active and passive listening. While many aspects of efferent anatomy, physiology and function are well established, others remain controversial. This article reviews the current knowledge on olivocochlear efferents, with emphasis on human medial efferents. The review covers (1) the anatomy and physiology of olivocochlear efferents in animals; (2) the methods used for investigating this auditory feedback system in humans, their limitations and best practices; (3) the characteristics of medial-olivocochlear efferents in humans, with a critical analysis of some discrepancies across human studies and between animal and human studies; (4) the possible roles of olivocochlear efferents in hearing, discussing the evidence in favor and against their role in facilitating the detection of signals in noise and in protecting the auditory system from excessive acoustic stimulation; and (5) the emerging association between abnormal olivocochlear efferent function and several health conditions. Finally, we summarize some open issues and introduce promising approaches for investigating the roles of efferents in human hearing using cochlear implants.
Collapse
Affiliation(s)
- Enrique A Lopez-Poveda
- Instituto de Neurociencias de Castilla y León, Universidad de Salamanca, Salamanca, Spain.,Departamento de Cirugía, Facultad de Medicina, Universidad de Salamanca, Salamanca, Spain.,Instituto de Investigación Biomédica de Salamanca, Universidad de Salamanca, Salamanca, Spain
| |
Collapse
|
10
|
Marrufo-Pérez MI, Eustaquio-Martín A, López-Bascuas LE, Lopez-Poveda EA. Temporal Effects on Monaural Amplitude-Modulation Sensitivity in Ipsilateral, Contralateral and Bilateral Noise. J Assoc Res Otolaryngol 2018; 19:147-161. [PMID: 29508100 DOI: 10.1007/s10162-018-0656-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2017] [Accepted: 02/05/2018] [Indexed: 10/17/2022] Open
Abstract
The amplitude modulations (AMs) in speech signals are useful cues for speech recognition. Several adaptation mechanisms may make the detection of AM in noisy backgrounds easier when the AM carrier is presented later rather than earlier in the noise. The aim of the present study was to characterize temporal adaptation to noise in AM detection. AM detection thresholds were measured for monaural (50 ms, 1.5 kHz) pure-tone carriers presented at the onset ('early' condition) and 300 ms after the onset ('late' condition) of ipsilateral, contralateral, and bilateral (diotic) broadband noise, as well as in quiet. Thresholds were 2-4 dB better in the late than in the early condition for the three noise lateralities. The temporal effect held for carriers at equal sensation levels, confirming that it was not due to overshoot on carrier audibility. The temporal effect was larger for broadband than for low-band contralateral noises. Many aspects in the results were consistent with the noise activating the medial olivocochlear reflex (MOCR) and enhancing AM depth in the peripheral auditory response. Other aspects, however, indicate that central masking and adaptation unrelated to the MOCR also affect both carrier-tone and AM detection and are involved in the temporal effects.
Collapse
Affiliation(s)
- Miriam I Marrufo-Pérez
- Instituto de Neurociencias de Castilla y León, Universidad de Salamanca, Calle Pintor Fernando Gallego 1, 37007, Salamanca, Spain.,Instituto de Investigación Biomédica de Salamanca, Universidad de Salamanca, Salamanca, Spain
| | - Almudena Eustaquio-Martín
- Instituto de Neurociencias de Castilla y León, Universidad de Salamanca, Calle Pintor Fernando Gallego 1, 37007, Salamanca, Spain.,Instituto de Investigación Biomédica de Salamanca, Universidad de Salamanca, Salamanca, Spain
| | - Luis E López-Bascuas
- Departamento de Psicología Básica I (Procesos Básicos), Universidad Complutense de Madrid, Madrid, Spain
| | - Enrique A Lopez-Poveda
- Instituto de Neurociencias de Castilla y León, Universidad de Salamanca, Calle Pintor Fernando Gallego 1, 37007, Salamanca, Spain. .,Instituto de Investigación Biomédica de Salamanca, Universidad de Salamanca, Salamanca, Spain. .,Departamento de Cirugía, Universidad de Salamanca, Salamanca, Spain.
| |
Collapse
|
11
|
Verschooten E, Strickland EA, Verhaert N, Joris PX. Assessment of Ipsilateral Efferent Effects in Human via ECochG. Front Neurosci 2017; 11:331. [PMID: 28642679 PMCID: PMC5462931 DOI: 10.3389/fnins.2017.00331] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2017] [Accepted: 05/26/2017] [Indexed: 11/16/2022] Open
Abstract
Development of electrophysiological means to assess the medial olivocochlear (MOC) system in humans is important to further our understanding of the function of that system and for the refinement and validation of psychoacoustical and otoacoustic emission methods which are thought to probe the MOC. Based on measurements in anesthetized animals it has been hypothesized that the MOC-reflex (MOCR) can enhance the response to signals in noise, and several lines of evidence support such a role in humans. A difficulty in these studies is the isolation of efferent effects. Efferent activation can be triggered by acoustic stimulation of the contralateral or ipsilateral ear, but ipsilateral stimulation is thought to be more effective. However, ipsilateral stimulation complicates interpretation of effects since these sounds can affect the perception of other ipsilateral sounds by mechanisms not involving olivocochlear efferents. We assessed the ipsilaterally evoked MOCR in human using a transtympanic procedure to record mass-potentials from the cochlear promontory or the niche of the round window. Averaged compound action potential (CAP) responses to masked probe tones of 4 kHz with and without a precursor (designed to activate the MOCR but not the stapedius reflex) were extracted with a polarity alternating paradigm. The masker was either a simultaneous narrow band noise masker or a short (20-ms) tonal ON- or OFF-frequency forward masker. The subjects were screened for normal hearing (audiogram, tympanogram, threshold stapedius reflex) and psychoacoustically tested for the presence of a precursor effect. We observed a clear reduction of CAP amplitude by the precursor, for different masking conditions. Even without an MOCR, this is expected because the precursor will affect the response to subsequent stimuli via neural adaptation. To determine whether the precursor also activated the efferent system, we measured the CAP over a range of masker levels, with or without precursor, and for different types of masker. The results show CAP reduction consistent with the type of gain reduction caused by the MOCR. These results generally support psychoacoustical paradigms designed to probe the efferent system as indeed activating the MOCR system, but not all observations are consistent with this mechanism.
Collapse
Affiliation(s)
- Eric Verschooten
- Laboratory of Auditory Neurophysiology, Department of Neurosciences, University of LeuvenLeuven, Belgium
| | - Elizabeth A. Strickland
- Department of Speech, Language, and Hearing Sciences, Purdue UniversityWest Lafayette, IN, United States
| | - Nicolas Verhaert
- ExpORL Research Group, Department of Neurosciences, University of LeuvenLeuven, Belgium
| | - Philip X. Joris
- Laboratory of Auditory Neurophysiology, Department of Neurosciences, University of LeuvenLeuven, Belgium
| |
Collapse
|
12
|
Rocchi F, Dylla ME, Bohlen PA, Ramachandran R. Spatial and temporal disparity in signals and maskers affects signal detection in non-human primates. Hear Res 2017; 344:1-12. [PMID: 27770624 PMCID: PMC5239734 DOI: 10.1016/j.heares.2016.10.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2016] [Revised: 10/10/2016] [Accepted: 10/15/2016] [Indexed: 12/25/2022]
Abstract
Detection thresholds for auditory stimuli (signals) increase in the presence of maskers. Natural environments contain maskers/distractors that can have a wide range of spatiotemporal properties relative to the signal. While these parameters have been well explored psychophysically in humans, they have not been well explored in animal models, and their neuronal underpinnings are not well understood. As a precursor to the neuronal measurements, we report the effects of systematically varying the spatial and temporal relationship between signals and noise in macaque monkeys (Macaca mulatta and Macaca radiata). Macaques detected tones masked by noise in a Go/No-Go task in which the spatiotemporal relationships between the tone and noise were systematically varied. Masked thresholds were higher when the masker was continuous or gated on and off simultaneously with the signal, and lower when the continuous masker was turned off during the signal. A burst of noise caused higher masked thresholds if it completely temporally overlapped with the signal, whereas partial overlap resulted in lower thresholds. Noise durations needed to be at least 100 ms before significant masking could be observed. Thresholds for short duration tones were significantly higher when the onsets of signal and masker coincided compared to when the signal was presented during the steady state portion of the noise (overshoot). When signal and masker were separated in space, masked signal detection thresholds decreased relative to when the masker and signal were co-located (spatial release from masking). Masking release was larger for azimuthal separations than for elevation separations. These results in macaques are similar to those observed in humans, suggesting that the specific spatiotemporal relationship between signal and masker determine threshold in natural environments for macaques in a manner similar to humans. These results form the basis for future investigations of neuronal correlates and mechanisms of masking.
Collapse
Affiliation(s)
- Francesca Rocchi
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN 37212, USA
| | - Margit E Dylla
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN 37212, USA
| | - Peter A Bohlen
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN 37212, USA
| | - Ramnarayan Ramachandran
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN 37212, USA.
| |
Collapse
|
13
|
Fletcher MD, Krumbholz K, de Boer J. Effect of Contralateral Medial Olivocochlear Feedback on Perceptual Estimates of Cochlear Gain and Compression. J Assoc Res Otolaryngol 2016; 17:559-575. [PMID: 27550069 PMCID: PMC5112214 DOI: 10.1007/s10162-016-0574-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2015] [Accepted: 06/17/2016] [Indexed: 11/16/2022] Open
Abstract
The active cochlear mechanism amplifies responses to low-intensity sounds, compresses the range of input sound intensities to a smaller output range, and increases cochlear frequency selectivity. The gain of the active mechanism can be modulated by the medial olivocochlear (MOC) efferent system, creating the possibility of top-down control at the earliest level of auditory processing. In humans, MOC function has mostly been measured by the suppression of otoacoustic emissions (OAEs), typically as a result of MOC activation by a contralateral elicitor sound. The exact relationship between OAE suppression and cochlear gain reduction, however, remains unclear. Here, we measured the effect of a contralateral MOC elicitor on perceptual estimates of cochlear gain and compression, obtained using the established temporal masking curve (TMC) method. The measurements were taken at a signal frequency of 2 kHz and compared with measurements of click-evoked OAE suppression. The elicitor was a broadband noise, set to a sound pressure level of 54 dB to avoid triggering the middle ear muscle reflex. Despite its low level, the elicitor had a significant effect on the TMCs, consistent with a reduction in cochlear gain. The amount of gain reduction was estimated as 4.4 dB on average, corresponding to around 18 % of the without-elicitor gain. As a result, the compression exponent increased from 0.18 to 0.27.
Collapse
Affiliation(s)
- Mark D Fletcher
- Medical Research Council Institute of Hearing Research, The University of Nottingham, University Park, Nottingham, NG7 2RD, UK
- School of Psychology, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
- Institute of Sound and Vibration Research, University of Southampton, Highfield Campus, Southampton, SO17 1BJ, UK
| | - Katrin Krumbholz
- Medical Research Council Institute of Hearing Research, The University of Nottingham, University Park, Nottingham, NG7 2RD, UK.
| | - Jessica de Boer
- Medical Research Council Institute of Hearing Research, The University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| |
Collapse
|
14
|
Necciari T, Laback B, Savel S, Ystad S, Balazs P, Meunier S, Kronland-Martinet R. Auditory Time-Frequency Masking for Spectrally and Temporally Maximally-Compact Stimuli. PLoS One 2016; 11:e0166937. [PMID: 27875575 PMCID: PMC5119819 DOI: 10.1371/journal.pone.0166937] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2016] [Accepted: 11/07/2016] [Indexed: 11/18/2022] Open
Abstract
Many audio applications perform perception-based time-frequency (TF) analysis by decomposing sounds into a set of functions with good TF localization (i.e. with a small essential support in the TF domain) using TF transforms and applying psychoacoustic models of auditory masking to the transform coefficients. To accurately predict masking interactions between coefficients, the TF properties of the model should match those of the transform. This involves having masking data for stimuli with good TF localization. However, little is known about TF masking for mathematically well-localized signals. Most existing masking studies used stimuli that are broad in time and/or frequency and few studies involved TF conditions. Consequently, the present study had two goals. The first was to collect TF masking data for well-localized stimuli in humans. Masker and target were 10-ms Gaussian-shaped sinusoids with a bandwidth of approximately one critical band. The overall pattern of results is qualitatively similar to existing data for long maskers. To facilitate implementation in audio processing algorithms, a dataset provides the measured TF masking function. The second goal was to assess the potential effect of auditory efferents on TF masking using a modeling approach. The temporal window model of masking was used to predict present and existing data in two configurations: (1) with standard model parameters (i.e. without efferents), (2) with cochlear gain reduction to simulate the activation of efferents. The ability of the model to predict the present data was quite good with the standard configuration but highly degraded with gain reduction. Conversely, the ability of the model to predict existing data for long maskers was better with than without gain reduction. Overall, the model predictions suggest that TF masking can be affected by efferent (or other) effects that reduce cochlear gain. Such effects were avoided in the experiment of this study by using maximally-compact stimuli.
Collapse
Affiliation(s)
- Thibaud Necciari
- Acoustics Research Institute, Austrian Academy of Sciences, Vienna, Austria
| | - Bernhard Laback
- Acoustics Research Institute, Austrian Academy of Sciences, Vienna, Austria
| | - Sophie Savel
- Laboratoire de Mécanique et d’Acoustique, CNRS UPR 7051, Equipe Sons, Aix-Marseille Université, Centrale Marseille, Marseille, France
| | - Sølvi Ystad
- Laboratoire de Mécanique et d’Acoustique, CNRS UPR 7051, Equipe Sons, Aix-Marseille Université, Centrale Marseille, Marseille, France
| | - Peter Balazs
- Acoustics Research Institute, Austrian Academy of Sciences, Vienna, Austria
| | - Sabine Meunier
- Laboratoire de Mécanique et d’Acoustique, CNRS UPR 7051, Equipe Sons, Aix-Marseille Université, Centrale Marseille, Marseille, France
| | - Richard Kronland-Martinet
- Laboratoire de Mécanique et d’Acoustique, CNRS UPR 7051, Equipe Sons, Aix-Marseille Université, Centrale Marseille, Marseille, France
| |
Collapse
|
15
|
Jennings SG, Ahlstrom JB, Dubno JR. Effects of age and hearing loss on overshoot. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2016; 140:2481. [PMID: 27794300 PMCID: PMC5065574 DOI: 10.1121/1.4964267] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2015] [Revised: 09/19/2016] [Accepted: 09/21/2016] [Indexed: 06/01/2023]
Abstract
The detection of a brief, sinusoidal probe in a long broadband, simultaneous masker improves as the probe is delayed from the masker's onset. This improvement ("overshoot") may be mediated by a reduction in cochlear amplifier gain over the timecourse of the masker via the medial olivocochlear (MOC) reflex. Overshoot was measured in younger adults with normal hearing and in older adults with normal and impaired hearing to test the hypothesis that aging and cochlear hearing loss result in abnormal overshoot, consistent with changes in certain structures along the MOC pathway. Overshoot decreased with increasing quiet probe thresholds and was only minimally influenced by increasing age. Marked individual differences in overshoot were observed due to differences in masking thresholds for probes presented near the masker's onset. Model simulations support the interpretation that reduced overshoot in hearing-impaired listeners is due to limited cochlear amplifier gain and therefore less gain to adjust over the timecourse of the masker. Similar overshoot among younger and older adults with normal hearing suggests that age-related changes to mechanisms underlying overshoot do not result in significant differences in overshoot among younger and older adults with normal hearing.
Collapse
Affiliation(s)
- Skyler G Jennings
- Department of Communication Sciences and Disorders, The University of Utah, 390 South, 1530 East, Behavioral Science Building 1201, Salt Lake City, Utah 84112, USA
| | - Jayne B Ahlstrom
- Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, 135 Rutledge Avenue, MSC 550, Charleston, South Carolina 29425-5500, USA
| | - Judy R Dubno
- Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, 135 Rutledge Avenue, MSC 550, Charleston, South Carolina 29425-5500, USA
| |
Collapse
|
16
|
Stilp CE, Anderson PW, Assgari AA, Ellis GM, Zahorik P. Speech perception adjusts to stable spectrotemporal properties of the listening environment. Hear Res 2016; 341:168-178. [PMID: 27596251 DOI: 10.1016/j.heares.2016.08.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2016] [Revised: 08/10/2016] [Accepted: 08/15/2016] [Indexed: 11/24/2022]
Abstract
When perceiving speech, listeners compensate for reverberation and stable spectral peaks in the speech signal. Despite natural listening conditions usually adding both reverberation and spectral coloration, these processes have only been studied separately. Reverberation smears spectral peaks across time, which is predicted to increase listeners' compensation for these peaks. This prediction was tested using sentences presented with or without a simulated reverberant sound field. All sentences had a stable spectral peak (added by amplifying frequencies matching the second formant frequency [F2] in the target vowel) before a test vowel varying from /i/ to /u/ in F2 and spectral envelope (tilt). In Experiment 1, listeners demonstrated increased compensation (larger decrease in F2 weights and larger increase in spectral tilt weights for identifying the target vowel) in reverberant speech than in nonreverberant speech. In Experiment 2, increased compensation was shown not to be due to reverberation tails. In Experiment 3, adding a pure tone to nonreverberant speech at the target vowel's F2 frequency increased compensation, revealing that these effects are not specific to reverberation. Results suggest that perceptual adjustment to stable spectral peaks in the listening environment is not affected by their source or cause.
Collapse
Affiliation(s)
- Christian E Stilp
- Department of Psychological and Brain Sciences, University of Louisville, Louisville, KY, 40292, USA.
| | - Paul W Anderson
- Department of Psychology, Murray State University, Murray, KY, 42071, USA.
| | - Ashley A Assgari
- Department of Psychological and Brain Sciences, University of Louisville, Louisville, KY, 40292, USA.
| | - Gregory M Ellis
- Department of Psychological and Brain Sciences, University of Louisville, Louisville, KY, 40292, USA.
| | - Pavel Zahorik
- Department of Psychological and Brain Sciences, University of Louisville, Louisville, KY, 40292, USA.
| |
Collapse
|
17
|
Lichtenhan JT, Wilson US, Hancock KE, Guinan JJ. Medial olivocochlear efferent reflex inhibition of human cochlear nerve responses. Hear Res 2016; 333:216-224. [PMID: 26364824 PMCID: PMC4788580 DOI: 10.1016/j.heares.2015.09.001] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2015] [Accepted: 09/02/2015] [Indexed: 11/24/2022]
Abstract
Inhibition of cochlear amplifier gain by the medial olivocochlear (MOC) efferent system has several putative roles: aiding listening in noise, protection against damage from acoustic overexposure, and slowing age-induced hearing loss. The human MOC reflex has been studied almost exclusively by measuring changes in otoacoustic emissions. However, to help understand how the MOC system influences what we hear, it is important to have measurements of the MOC effect on the total output of the organ of Corti, i.e., on cochlear nerve responses that couple sounds to the brain. In this work we measured the inhibition produced by the MOC reflex on the amplitude of cochlear nerve compound action potentials (CAPs) in response to moderate level (52-60 dB peSPL) clicks from five, young, normal hearing, awake, alert, human adults. MOC activity was elicited by 65 dB SPL, contralateral broadband noise (CAS). Using tympanic membrane electrodes, approximately 10 h of data collection were needed from each subject to yield reliable measurements of the MOC reflex inhibition on CAP amplitudes from one click level. The CAS produced a 16% reduction of CAP amplitude, equivalent to a 1.98 dB effective attenuation (averaged over five subjects). Based on previous reports of efferent effects as functions of level and frequency, it is possible that much larger effective attenuations would be observed at lower sound levels or with clicks of higher frequency content. For a preliminary comparison, we also measured MOC reflex inhibition of DPOAEs evoked from the same ears with f2's near 4 kHz. The resulting effective attenuations on DPOAEs were, on average, less than half the effective attenuations on CAPs.
Collapse
Affiliation(s)
- J T Lichtenhan
- Washington University School of Medicine, Department of Otolaryngology, Saint Louis, MO 63110, USA.
| | - U S Wilson
- Washington University School of Medicine, Department of Otolaryngology, Saint Louis, MO 63110, USA; Missouri State University, Communications Sciences and Disorders, Springfield, MO 65897, USA
| | - K E Hancock
- Massachusetts Eye & Ear Infirmary, Eaton-Peabody Laboratory of Auditory Physiology, Boston, MA 02114, USA; Harvard Medical School, Department of Otology and Laryngology, Boston, MA 02115, USA
| | - J J Guinan
- Massachusetts Eye & Ear Infirmary, Eaton-Peabody Laboratory of Auditory Physiology, Boston, MA 02114, USA; Harvard Medical School, Department of Otology and Laryngology, Boston, MA 02115, USA
| |
Collapse
|
18
|
Feng L, Oxenham AJ. New perspectives on the measurement and time course of auditory enhancement. J Exp Psychol Hum Percept Perform 2015; 41:1696-708. [PMID: 26280269 DOI: 10.1037/xhp0000115] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
A target sound can become more audible and may "pop out" from a simultaneously presented masker if the masker is presented first by itself, as a precursor. This phenomenon, known as auditory enhancement, may reflect the general perceptual principle of contrast enhancement, which facilitates adaptation to ongoing acoustic conditions and the detection of new events. Little is known about the mechanisms underlying enhancement, and potential confounding factors have made the size of the effect and its time course a point of contention. Here we measured enhancement as a function of precursor duration and delay between precursor offset and target onset, using 2 single-interval pitch comparison tasks, which involve either same-different or up-down judgments, to avoid the potential confounds of earlier studies. Although these 2 tasks elicit different levels of performance and may reflect different underlying mechanisms, they produced similar amounts of enhancement. The effect decreased with decreasing precursor duration, but remained present for precursors as short as 62.5 ms, and decreased with increasing gap between the precursor and target, but remained measurable 1 s after the precursor. Additional conditions, examining the effect of precursor/masker similarity and the possible role of grouping and cueing, suggest multiple sources of auditory enhancement.
Collapse
Affiliation(s)
- Lei Feng
- Department of Otolaryngology, University of Minnesota
| | | |
Collapse
|
19
|
Stimulus Frequency Otoacoustic Emissions Provide No Evidence for the Role of Efferents in the Enhancement Effect. J Assoc Res Otolaryngol 2015; 16:613-29. [PMID: 26153415 DOI: 10.1007/s10162-015-0534-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2015] [Accepted: 06/18/2015] [Indexed: 10/23/2022] Open
Abstract
Auditory enhancement refers to the perceptual phenomenon that a target sound is heard out more readily from a background sound if the background is presented alone first. Here we used stimulus-frequency otoacoustic emissions (SFOAEs) to test the hypothesis that activation of the medial olivocochlear efferent system contributes to auditory enhancement effects. The SFOAEs were used as a tool to measure changes in cochlear responses to a target component and the neighboring components of a multitone background between conditions producing enhancement and conditions producing no enhancement. In the "enhancement" condition, the target and multitone background were preceded by a precursor stimulus with a spectral notch around the signal frequency; in the control (no-enhancement) condition, the target and multitone background were presented without the precursor. In an experiment using a wideband multitone stimulus known to produce significant psychophysical enhancement effects, SFOAEs showed no changes consistent with enhancement, but some aspects of the results indicated possible contamination of the SFOAE magnitudes by the activation of the middle-ear-muscle reflex. The same SFOAE measurements performed using narrower-band stimuli at lower sound levels also showed no SFOAE changes consistent with either absolute or relative enhancement despite robust psychophysical enhancement effects observed in the same listeners with the same stimuli. The results suggest that cochlear efferent control does not play a significant role in auditory enhancement effects.
Collapse
|
20
|
Roverud E, Strickland EA. Exploring the source of the mid-level hump for intensity discrimination in quiet and the effects of noise. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2015; 137:1318-35. [PMID: 25786945 PMCID: PMC4368585 DOI: 10.1121/1.4908243] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2014] [Revised: 01/28/2015] [Accepted: 01/30/2015] [Indexed: 05/29/2023]
Abstract
Intensity discrimination Weber fractions (WFs) measured for short, high-frequency tones in quiet are larger at mid levels than at lower or higher levels. The source of this "mid-level hump" is a matter of debate. One theory is that the mid-level hump reflects basilar-membrane compression, and that WFs decrease at higher levels due to spread-of-excitation cues. To test this theory, Experiment 1 measured the mid-level hump and growth-of-masking functions to estimate the basilar membrane input/output (I/O) function in the same listeners. Results showed the initial rise in WFs could be accounted for by the change in I/O function slope, but there was additional unexplained variability in WFs. Previously, Plack [(1998). J. Acoust. Soc. Am. 103(5), 2530-2538] showed that long-duration notched noise (NN) presented with the tone reduced the mid-level hump even with a temporal gap in the NN. Plack concluded the results were consistent with central profile analysis. However, simultaneous, forward, and backward NN were not examined separately, which may independently test peripheral and central mechanisms of the NN. Experiment 2 measured WFs at the mid-level hump in the presence of NN and narrowband noise of different durations and temporal positions relative to the tone. Results varied across subjects, but were consistent with more peripheral mechanisms.
Collapse
Affiliation(s)
- Elin Roverud
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907
| | - Elizabeth A Strickland
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907
| |
Collapse
|
21
|
Fletcher M, de Boer J, Krumbholz K. Is off-frequency overshoot caused by adaptation of suppression? J Assoc Res Otolaryngol 2014; 16:241-53. [PMID: 25468405 PMCID: PMC4368652 DOI: 10.1007/s10162-014-0498-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2014] [Accepted: 10/29/2014] [Indexed: 11/25/2022] Open
Abstract
This study is concerned with the mechanism of off-frequency overshoot. Overshoot refers to the phenomenon whereby a brief signal presented at the onset of a masker is easier to detect when the masker is preceded by a “precursor” sound (which is often the same as the masker). Overshoot is most prominent when the masker and precursor have a different frequency than the signal (henceforth referred to as “off-frequency overshoot”). It has been suggested that off-frequency overshoot is based on a similar mechanism as “enhancement,” which refers to the perceptual pop-out of a signal after presentation of a precursor that contains a spectral notch at the signal frequency; both have been proposed to be caused by a reduction in the suppressive masking of the signal as a result of the adaptive effect of the precursor (“adaptation of suppression”). In this study, we measured overshoot, suppression, and adaptation of suppression for a 4-kHz sinusoidal signal and a 4.75-kHz sinusoidal masker and precursor, using the same set of participants. We show that, while the precursor yielded strong overshoot and the masker produced strong suppression, the precursor did not appear to cause any reduction (adaptation) of suppression. Predictions based on an established model of the cochlear input–output function indicate that our failure to obtain any adaptation of suppression is unlikely to represent a false negative outcome. Our results indicate that off-frequency overshoot and enhancement are likely caused by different mechanisms. We argue that overshoot may be due to higher-order perceptual factors such as transient masking or attentional diversion, whereas enhancement may be based on mechanisms similar to those that generate the Zwicker tone.
Collapse
|
22
|
Yasin I, Drga V, Plack CJ. Effect of human auditory efferent feedback on cochlear gain and compression. J Neurosci 2014; 34:15319-26. [PMID: 25392499 PMCID: PMC4228134 DOI: 10.1523/jneurosci.1043-14.2014] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2014] [Revised: 09/10/2014] [Accepted: 09/13/2014] [Indexed: 11/21/2022] Open
Abstract
The mammalian auditory system includes a brainstem-mediated efferent pathway from the superior olivary complex by way of the medial olivocochlear system, which reduces the cochlear response to sound (Warr and Guinan, 1979; Liberman et al., 1996). The human medial olivocochlear response has an onset delay of between 25 and 40 ms and rise and decay constants in the region of 280 and 160 ms, respectively (Backus and Guinan, 2006). Physiological studies with nonhuman mammals indicate that onset and decay characteristics of efferent activation are dependent on the temporal and level characteristics of the auditory stimulus (Bacon and Smith, 1991; Guinan and Stankovic, 1996). This study uses a novel psychoacoustical masking technique using a precursor sound to obtain a measure of the efferent effect in humans. This technique avoids confounds currently associated with other psychoacoustical measures. Both temporal and level dependency of the efferent effect was measured, providing a comprehensive measure of the effect of human auditory efferents on cochlear gain and compression. Results indicate that a precursor (>20 dB SPL) induced efferent activation, resulting in a decrease in both maximum gain and maximum compression, with linearization of the compressive function for input sound levels between 50 and 70 dB SPL. Estimated gain decreased as precursor level increased, and increased as the silent interval between the precursor and combined masker-signal stimulus increased, consistent with a decay of the efferent effect. Human auditory efferent activation linearizes the cochlear response for mid-level sounds while reducing maximum gain.
Collapse
Affiliation(s)
- Ifat Yasin
- Ear Institute, University College London, London WC1X 8EE, United Kingdom, and
| | - Vit Drga
- Ear Institute, University College London, London WC1X 8EE, United Kingdom, and
| | - Christopher J Plack
- School of Psychological Sciences, University of Manchester, Manchester Academic Health Science Centre, Manchester M13 9PL, United Kingdom
| |
Collapse
|
23
|
Wojtczak M, Beim JA, Oxenham AJ. Exploring the role of feedback-based auditory reflexes in forward masking by schroeder-phase complexes. J Assoc Res Otolaryngol 2014; 16:81-99. [PMID: 25338224 DOI: 10.1007/s10162-014-0495-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2014] [Accepted: 10/02/2014] [Indexed: 10/24/2022] Open
Abstract
Several studies have postulated that psychoacoustic measures of auditory perception are influenced by efferent-induced changes in cochlear responses, but these postulations have generally remained untested. This study measured the effect of stimulus phase curvature and temporal envelope modulation on the medial olivocochlear reflex (MOCR) and on the middle-ear muscle reflex (MEMR). The role of the MOCR was tested by measuring changes in the ear-canal pressure at 6 kHz in the presence and absence of a band-limited harmonic complex tone with various phase curvatures, centered either at (on-frequency) or well below (off-frequency) the 6-kHz probe frequency. The influence of possible MEMR effects was examined by measuring phase-gradient functions for the elicitor effects and by measuring changes in the ear-canal pressure with a continuous suppressor of the 6-kHz probe. Both on- and off-frequency complex tone elicitors produced significant changes in ear canal sound pressure. However, the pattern of results was not consistent with the earlier hypotheses postulating that efferent effects produce the psychoacoustic dependence of forward-masked thresholds on masker phase curvature. The results also reveal unexpectedly long time constants associated with some efferent effects, the source of which remains unknown.
Collapse
Affiliation(s)
- Magdalena Wojtczak
- Department of Psychology, University of Minnesota, N218 Elliott Hall, 75 East River Rd., Minneapolis, MN, 55455, USA,
| | | | | |
Collapse
|
24
|
Carcagno S, Plack CJ, Portron A, Semal C, Demany L. The auditory enhancement effect is not reflected in the 80-Hz auditory steady-state response. J Assoc Res Otolaryngol 2014; 15:621-30. [PMID: 24845402 DOI: 10.1007/s10162-014-0455-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2014] [Accepted: 04/04/2014] [Indexed: 10/25/2022] Open
Abstract
The perceptual salience of a target tone presented in a multitone background is increased by the presentation of a precursor sound consisting of the multitone background alone. It has been proposed that this "enhancement" phenomenon results from an effective amplification of the neural response to the target tone. In this study, we tested this hypothesis in humans, by comparing the auditory steady-state response (ASSR) to a target tone that was enhanced by a precursor sound with the ASSR to a target tone that was not enhanced. In order to record neural responses originating in the brainstem, the ASSR was elicited by amplitude modulating the target tone at a frequency close to 80 Hz. The results did not show evidence of an amplified neural response to enhanced tones. In a control condition, we measured the ASSR to a target tone that, instead of being perceptually enhanced by a precursor sound, was acoustically increased in level. This level increase matched the magnitude of enhancement estimated psychophysically with a forward masking paradigm in a previous experimental phase. We found that the ASSR to the tone acoustically increased in level was significantly greater than the ASSR to the tone enhanced by the precursor sound. Overall, our results suggest that the enhancement effect cannot be explained by an amplified neural response at the level of the brainstem. However, an alternative possibility is that brainstem neurons with enhanced responses do not contribute to the scalp-recorded ASSR.
Collapse
Affiliation(s)
- Samuele Carcagno
- Institut de Neurosciences Cognitives et Intégratives d'Aquitaine, Université de Bordeaux and CNRS, Bordeaux, France,
| | | | | | | | | |
Collapse
|
25
|
Is overshoot caused by an efferent reduction in cochlear gain? ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2013; 787:65-72. [PMID: 23716210 DOI: 10.1007/978-1-4614-1590-9_8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/20/2023]
Abstract
Under certain conditions, detection of a masked tone is improved by a preceding sound ("precursor"). This phenomenon is referred to as the "temporal effect" or "overshoot". A prevalent model of overshoot, referred to as the "gain reduction model", posits that overshoot is caused by efferent reduction in cochlear gain mediated by the medial olivocochlear (MOC) bundle. The model predicts that reduction in cochlear gain will reduce masking when masking is suppressive or when masking is excitatory and the signal-to-masker ratio is high. This study was aimed at testing the validity of these predictions. It consisted of two experiments. The first experiment investigated the relative contributions of suppressive versus excitatory masking to overshoot. The signal was a short 4-kHz tone pip, and the masker and precursor were limited to contain energy either only within (-on-frequency) or only outside (off-frequency) the cochlear filter around the signal frequency. The on-frequency masker would be expected to cause mainly excitatory masking, whereas masking by the off-frequency masker would be expected to be mainly suppressive. Only the off-frequency masker and precursor yielded -significant overshoot. This suggests that measurable overshoot requires suppressive masking. The second experiment sought to quantify the effect of a precursor on cochlear -suppression more directly by measuring the amount of suppression caused by a 4.75-kHz suppressor on a lower-frequency (4-kHz) suppressee with and without a precursor present. Suppression was measured using a forward-masking paradigm. While we found large suppression and large overshoot, we found no reduction in suppression by the precursor. This is contrary to the gain reduction model. Taken together, our results indicate that measurable overshoot requires off-frequency masking and that off-frequency overshoot must be caused by a mechanism other than MOC-mediated reduction in cochlear suppression.
Collapse
|
26
|
Carcagno S, Semal C, Demany L. No Need for Templates in the Auditory Enhancement Effect. PLoS One 2013; 8:e67874. [PMID: 23826348 PMCID: PMC3694896 DOI: 10.1371/journal.pone.0067874] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2013] [Accepted: 05/23/2013] [Indexed: 11/18/2022] Open
Abstract
The audibility of a target tone in a multitone background masker is enhanced by the presentation of a precursor sound consisting of the masker alone. There is evidence that precursor-induced neural adaptation plays a role in this perceptual enhancement. However, the precursor may also be strategically used by listeners as a spectral template of the following masker to better segregate it from the target. In the present study, we tested this hypothesis by measuring the audibility of a target tone in a multitone masker after the presentation of precursors which, in some conditions, were made dissimilar to the masker by gating their components asynchronously. The precursor and the following sound were presented either to the same ear or to opposite ears. In either case, we found no significant difference in the amount of enhancement produced by synchronous and asynchronous precursors. In a second experiment, listeners had to judge whether a synchronous multitone complex contained exactly the same tones as a preceding precursor complex or had one tone less. In this experiment, listeners performed significantly better with synchronous than with asynchronous precursors, showing that asynchronous precursors were poorer perceptual templates of the synchronous multitone complexes. Overall, our findings indicate that precursor-induced auditory enhancement cannot be fully explained by the strategic use of the precursor as a template of the following masker. Our results are consistent with an explanation of enhancement based on selective neural adaptation taking place at a central locus of the auditory system.
Collapse
Affiliation(s)
- Samuele Carcagno
- Institut de Neurosciences Cognitives et Intégratives d'Aquitaine, Université de Bordeaux and CNRS, Bordeaux, France
- * E-mail:
| | - Catherine Semal
- Institut de Neurosciences Cognitives et Intégratives d'Aquitaine, Université de Bordeaux and CNRS, Bordeaux, France
| | - Laurent Demany
- Institut de Neurosciences Cognitives et Intégratives d'Aquitaine, Université de Bordeaux and CNRS, Bordeaux, France
| |
Collapse
|
27
|
Enhancement of increments in spectral amplitude: further evidence for a mechanism based on central adaptation. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2013; 787:175-82. [PMID: 23716222 DOI: 10.1007/978-1-4614-1590-9_20] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
The threshold for detecting a tone in a multitone masker is lower when the masker-plus-signal stimulus is preceded by a copy of the masker. One potential explanation of this "enhancement" phenomenon is that the -precursor stimulus acts as a "template" of the subsequent masker, thus helping listeners to segregate the signal from the masker. To assess this idea, we measured enhancement for precursors that were perceptually similar to the masker and for precursors that were made dissimilar to the masker by gating their components asynchronously. We found that the two types of precursor produced similar amounts of enhancement. This was true not only when the precursor and the subsequent test stimulus were presented to the same ear but also when they were presented to opposite ears. In a second experiment, we checked that the precursors with asynchronously gated components were perceptually poor templates of the subsequent maskers. Listeners now had to discriminate between test stimuli -containing the same components as the precursor and test stimuli containing all but one of the precursor components. We found that in this experimental situation, where enhancement could play no role, gating the precursor components asynchronously disrupted performance. Overall, our results are inconsistent with the hypothesis that precursors producing enhancement are beneficial because they are used as perceptual templates of the masker. Our results are instead consistent with an -explanation of enhancement based on selective neural adaptation taking place at a central locus of the auditory system.
Collapse
|
28
|
Shen Y, Richards VM. Investigating the auditory enhancement phenomenon using behavioral temporal masking patterns. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2012; 132:3363-74. [PMID: 23145617 PMCID: PMC3505209 DOI: 10.1121/1.4754527] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/08/2011] [Revised: 08/22/2012] [Accepted: 08/28/2012] [Indexed: 06/01/2023]
Abstract
A narrowband signal is subjected to less masking from a simultaneously presented notched masker if it is preceded by a precursor that occupies the same spectral region as the masker, a phenomenon referred to as enhancement. The present study investigated (i) the amount of enhancement for the detection of a narrowband noise added to a notched masker, and (ii) masking patterns associated with the detection of tone pips added to the narrowband signal. The resulting psychophysical data were compared to predictions generated using a model similar to the neural adaptation-of-inhibition model proposed by Nelson and Young [(2010b). J. Neurosci. 30, 6577-6587]. The amount of enhancement was measured as a function of the temporal separation between the precursor and masker in Experiment I, and as a function of precursor level in Experiment II. The model captured the temporal dynamics of psychophysical enhancement reasonably well for both the long-duration noise signals and the masking patterns. However, in contrast to psychophysical data which indicated reliable enhancement only when the precursor and masker shared the same levels, the model predicated enhancement at all precursor levels.
Collapse
Affiliation(s)
- Yi Shen
- Department of Cognitive Sciences, University of California, Irvine, California 92697-5100, USA.
| | | |
Collapse
|
29
|
Jennings SG, Strickland EA. Evaluating the effects of olivocochlear feedback on psychophysical measures of frequency selectivity. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2012; 132:2483-96. [PMID: 23039443 PMCID: PMC3477188 DOI: 10.1121/1.4742723] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2011] [Revised: 07/11/2012] [Accepted: 07/16/2012] [Indexed: 05/19/2023]
Abstract
Frequency selectivity was evaluated under two conditions designed to assess the influence of a "precursor" stimulus on auditory filter bandwidths. The standard condition consisted of a short masker, immediately followed by a short signal. The precursor condition was identical except a 100-ms sinusoid at the signal frequency (i.e., the precursor) was presented before the masker. The standard and precursor conditions were compared for measurements of psychophysical tuning curves (PTCs), and notched noise tuning characteristics. Estimates of frequency selectivity were significantly broader in the precursor condition. In the second experiment, PTCs in the standard and precursor conditions were simulated to evaluate the influence of the precursor on PTC bandwidth. The model was designed to account for the influence of additivity of masking between the masker and precursor. Model simulations were able to qualitatively account for the perceptual data when outer hair cell gain of the model was reduced in the precursor condition. These findings suggest that the precursor may have reduced cochlear gain, in addition to producing additivity of masking. This reduction in gain may be mediated by the medial olivocochlear reflex.
Collapse
Affiliation(s)
- Skyler G Jennings
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907, USA.
| | | |
Collapse
|
30
|
Jennings SG, Strickland EA. Auditory filter tuning inferred with short sinusoidal and notched-noise maskers. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2012; 132:2497-513. [PMID: 23039444 PMCID: PMC3477189 DOI: 10.1121/1.4746029] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2011] [Revised: 07/18/2012] [Accepted: 07/24/2012] [Indexed: 05/29/2023]
Abstract
The physiology of the medial olivocochlear reflex suggests that a sufficiently long stimulus (>100 ms) may reduce cochlear gain and result in broadened frequency selectivity. The current study attempted to avoid gain reduction by using short maskers (20 ms) to measure psychophysical tuning curves (PTCs) and notched-noise tuning characteristics, with a 4-kHz signal. The influence of off-frequency listening on PTCs was evaluated using two types of background noise. Iso-level curves were derived using an estimate of the cochlear input/output (I/O) function, which was obtained using an off-frequency masker as a linear reference. The influence of masker duration on PTCs was assessed using a model that assumed long maskers (>20 ms) evoked gain reduction. The results suggested that the off-frequency masker was a valid linear reference when deriving I/O functions and that off-frequency listening may have occurred in auditory filters apical to the signal place. The iso-level curves from this growth-of-masking study were consistent with those from a temporal-masking-curve study by Eustaquio-Martin and Lopez-Poveda [J. Assoc. Res. Otolaryngol. 12, 281-299. (2011)], suggesting that either approach may be used to derive iso-level curves. Finally, model simulations suggested that masker duration may not influence estimates of frequency selectivity.
Collapse
Affiliation(s)
- Skyler G Jennings
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907, USA.
| | | |
Collapse
|
31
|
Auditory enhancement of increments in spectral amplitude stems from more than one source. J Assoc Res Otolaryngol 2012; 13:693-702. [PMID: 22766695 DOI: 10.1007/s10162-012-0339-y] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2011] [Accepted: 06/13/2012] [Indexed: 10/28/2022] Open
Abstract
A component of a test sound consisting of simultaneous pure tones perceptually "pops out" if the test sound is preceded by a copy of itself with that component attenuated. Although this "enhancement" effect was initially thought to be purely monaural, it is also observable when the test sound and the precursor sound are presented contralaterally (i.e., to opposite ears). In experiment 1, we assessed the magnitude of ipsilateral and contralateral enhancement as a function of the time interval between the precursor and test sounds (10, 100, or 600 ms). The test sound, randomly transposed in frequency from trial to trial, was followed by a probe tone, either matched or mismatched in frequency to the test sound component which was the target of enhancement. Listeners' ability to discriminate matched probes from mismatched probes was taken as an index of enhancement magnitude. The results showed that enhancement decays more rapidly for ipsilateral than for contralateral precursors, suggesting that ipsilateral enhancement and contralateral enhancement stem from at least partly different sources. It could be hypothesized that, in experiment 1, contralateral precursors were effective only because they provided attentional cues about the target tone frequency. In experiment 2, this hypothesis was tested by presenting the probe tone before the precursor sound rather than after the test sound. Although the probe tone was then serving as a frequency cue, contralateral precursors were again found to produce enhancement. This indicates that contralateral enhancement cannot be explained by cuing alone and is a genuine sensory phenomenon.
Collapse
|
32
|
Erviti M, Semal C, Demany L. Enhancing a tone by shifting its frequency or intensity. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2011; 129:3837-3845. [PMID: 21682407 DOI: 10.1121/1.3589257] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
When a test sound consisting of pure tones with equal intensities is preceded by a precursor sound identical to the test sound except for a reduction in the intensity of one tone, an auditory "enhancement" phenomenon occurs: In the test sound, the tone which was previously softer stands out perceptually. Here, enhancement was investigated using inharmonic sounds made up of five pure tones well resolved in the auditory periphery. It was found that enhancement can be elicited not only by increases in intensity but also by shifts in frequency. In both cases, when the precursor and test sounds are separated by a 500-ms delay, inserting a burst of pink noise during the delay has little effect on enhancement. Presenting the precursor and test sounds to opposite ears rather than to the same ear significantly reduces the enhancement resulting from increases in intensity, but not the enhancement resulting from shifts in frequency. This difference suggests that the mechanisms of enhancement are not identical for the two types of change. For frequency shifts, enhancement may be partly based on the existence of automatic "frequency-shift detectors" [Demany and Ramos, J. Acoust. Soc. Am. 117, 833-841 (2005)].
Collapse
Affiliation(s)
- Mayalen Erviti
- Institut de Neurosciences Cognitives et Intégratives d'Aquitaine (UMR CNRS 5287), BP 63, Université de Bordeaux, 146 rue Leo Saignat, F-33076 Bordeaux, France
| | | | | |
Collapse
|
33
|
Jennings SG, Heinz MG, Strickland EA. Evaluating adaptation and olivocochlear efferent feedback as potential explanations of psychophysical overshoot. J Assoc Res Otolaryngol 2011; 12:345-60. [PMID: 21267622 DOI: 10.1007/s10162-011-0256-5] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2010] [Accepted: 01/10/2011] [Indexed: 11/24/2022] Open
Abstract
Masked detection threshold for a short tone in noise improves as the tone's onset is delayed from the masker's onset. This improvement, known as "overshoot," is maximal at mid-masker levels and is reduced by temporary and permanent cochlear hearing loss. Computational modeling was used in the present study to evaluate proposed physiological mechanisms of overshoot, including classic firing rate adaptation and medial olivocochlear (MOC) feedback, for both normal hearing and cochlear hearing loss conditions. These theories were tested using an established model of the auditory periphery and signal detection theory techniques. The influence of several analysis variables on predicted tone-pip detection in broadband noise was evaluated, including: auditory nerve fiber spontaneous-rate (SR) pooling, range of characteristic frequencies, number of synapses per characteristic frequency, analysis window duration, and detection rule. The results revealed that overshoot similar to perceptual data in terms of both magnitude and level dependence could be predicted when the effects of MOC efferent feedback were included in the auditory nerve model. Conversely, simulations without MOC feedback effects never produced overshoot despite the model's ability to account for classic firing rate adaptation and dynamic range adaptation in auditory nerve responses. Cochlear hearing loss was predicted to reduce the size of overshoot only for model versions that included the effects of MOC efferent feedback. These findings suggest that overshoot in normal and hearing-impaired listeners is mediated by some form of dynamic range adaptation other than what is observed in the auditory nerve of anesthetized animals. Mechanisms for this adaptation may occur at several levels along the auditory pathway. Among these mechanisms, the MOC reflex may play a leading role.
Collapse
Affiliation(s)
- Skyler G Jennings
- Department of Speech, Language, and Hearing Sciences, Purdue University, 500 Oval Drive, West Lafayette, IN 47907, USA.
| | | | | |
Collapse
|
34
|
McFadden D, Walsh KP, Pasanen EG, Grenwelge EM. Overshoot using very short signal delays. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2010; 128:1915-21. [PMID: 20968363 PMCID: PMC2981109 DOI: 10.1121/1.3480568] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2010] [Revised: 07/14/2010] [Accepted: 07/27/2010] [Indexed: 05/19/2023]
Abstract
The detectability of a 10-ms tone masked by a 400-ms wideband noise was measured as a function of the delay in the onset of the tone compared to the onset of the noise burst. Unlike most studies like this on auditory overshoot, special attention was given to signal delays between 0 and 45 ms. Nine well-practiced subjects were tested using an adaptive psychophysical procedure in which the level of the masking noise was adjusted to estimate 79% correct detections. Tones of both 3.0 and 4.0 kHz, at different levels, were used as signals. For the subjects showing overshoot, detectability remained approximately constant for at least 20-30 ms of signal delay, and then detectability began to improve gradually toward its maximum at about 150-200 ms. That is, there was a "hesitation" prior to detectability beginning to improve, and the duration of this hesitation was similar to that seen in physiological measurements of the medial olivocochlear (MOC) system. This result provides further support for the hypothesis that the MOC efferent system makes a major contribution to overshoot in simultaneous masking.
Collapse
Affiliation(s)
- Dennis McFadden
- Department of Psychology and Center for Perceptual Systems, University of Texas, 1 University Station A8000, Austin, Texas 78712-0187, USA.
| | | | | | | |
Collapse
|
35
|
Walsh KP, Pasanen EG, McFadden D. Overshoot measured physiologically and psychophysically in the same human ears. Hear Res 2010; 268:22-37. [PMID: 20430072 PMCID: PMC2923227 DOI: 10.1016/j.heares.2010.04.007] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/12/2009] [Revised: 04/18/2010] [Accepted: 04/21/2010] [Indexed: 11/15/2022]
Abstract
A nonlinear version of the stimulus-frequency otoacoustic emission (SFOAE) was measured using stimulus waveforms similar to those used for behavioral overshoot. Behaviorally, the seven listeners were as much as 11 dB worse at detecting a brief tonal signal (4.0 kHz, 10 ms in duration) when it occurred soon after the onset of a wideband masking noise (0.1-6.0 kHz; 400 ms in duration) than when it was delayed by about 200 ms, and the nonlinear SFOAE measure exhibited a similar effect. When either lowpass (0.1-3.8 kHz) or bandpass noise (3.8-4.2 kHz) was used instead of the wideband noise, the physiological and behavioral measures again were similar. When a highpass noise (4.2-6.0 kHz) was used, the physiological and behavioral measures both showed no overshoot-like effect for five of the subjects. The physiological response to the tone decayed slowly after the termination of the noise, much like the time course of resetting for behavioral overshoot. One subject exhibited no overshoot behaviorally even though his cochlear responses were like those of the other subjects. Overall, the evidence suggests that some basic characteristics of overshoot are obligatory consequences of cochlear function, as modulated by the olivocochlear efferent system.
Collapse
Affiliation(s)
- Kyle P Walsh
- Department of Psychology, Center for Perceptual Systems, Seay Building, 1 University Station, A8000, University of Texas, Austin, TX 78712-0187, USA.
| | | | | |
Collapse
|
36
|
Roverud E, Strickland EA. The time course of cochlear gain reduction measured using a more efficient psychophysical technique. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2010; 128:1203-14. [PMID: 20815456 PMCID: PMC2945748 DOI: 10.1121/1.3473695] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2009] [Revised: 07/02/2010] [Accepted: 07/06/2010] [Indexed: 05/09/2023]
Abstract
In a previous study it was shown that an on-frequency precursor intended to activate the medial olivocochlear reflex (MOCR) at the signal frequency reduces the gain estimated from growth-of-masking (GOM) functions. This is called the temporal effect (TE). In Expt. 1 a shorter method of measuring this change in gain is established. GOM functions were measured with an on- and off-frequency precursor presented before the masker and signal, and used to estimate Input/Output functions. The change in gain estimated in this way was very similar to that estimated from comparing two points measured with a single fixed masker level on the lower legs of the GOM functions. In Expt. 2, the TE was measured as a function of precursor duration and signal delay. For short precursor durations and short delays the TE increased (buildup) or remained constant as delay increased, then decreased. The TE also increased with precursor duration for the shortest delay. The results were fitted with a model based on the time course of the MOCR. The model fitted the data well, and predicted the buildup. This buildup is not consistent with exponential decay predicted by neural adaptation or persistence of excitation.
Collapse
Affiliation(s)
- Elin Roverud
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907-2038, USA.
| | | |
Collapse
|
37
|
Furness DN, Moore DR, Palmer AR, Summerfield Q. Abstracts of the British Society of Audiology Short Papers Meeting on Experimental Studies of Hearing and Deafness. Int J Audiol 2010. [DOI: 10.3109/14992027.2010.490242] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
38
|
Zhou X, Henin S, Thompson SE, Long GR, Parra LC. Sensitization to masked tones following notched-noise correlates with estimates of cochlear function using distortion product otoacoustic emissions. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2010; 127:970-976. [PMID: 20136219 DOI: 10.1121/1.3277156] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Neuronal gain adaptation has been proposed as the underlying mechanism leading to the perception of phantom sounds such as Zwicker tones and tinnitus. In this gain-adaptation theory, cochlear compression plays a significant role with weaker compression leading to stronger phantom percepts. The specific aim of this study was to find a link between the strength of neuronal gain adaptation and cochlear compression. Compression was assessed using distortion product otoacoustic emissions (DPOAEs). Gain adaptation is hypothesized to manifest itself in the sensitization observed for the detection of masked tones when preceded by notched noise. Perceptual thresholds for pure tones in notched noise were measured at multiple frequencies following various priming signals. The observed sensitization was larger than expected from the combined effect of the various maskers. However, there was no link between sensitization and compression. Instead, across subjects, stronger sensitization correlated with stronger DPOAEs evoked by low-level primaries. In addition, growth of DPOAEs correlated reliably with perceptual thresholds across frequencies within subjects. Together, the data suggest that short-term dynamic adaptation leading to perceptual sensitization is the result of an active process mediated by the outer hair cells, which are thought to modulate the gain of the cochlear amplifier via efferent feedback.
Collapse
Affiliation(s)
- Xiang Zhou
- Department of Biomedical Engineering, The City College of the City University of New York, Steinman Hall, Room T-401, Convent Avenue, 140th Street, New York, New York 10031, USA
| | | | | | | | | |
Collapse
|
39
|
Walsh KP, Pasanen EG, McFadden D. Properties of a nonlinear version of the stimulus-frequency otoacoustic emission. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2010; 127:955-69. [PMID: 20136218 PMCID: PMC2830262 DOI: 10.1121/1.3279832] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2009] [Revised: 12/04/2009] [Accepted: 12/07/2009] [Indexed: 05/19/2023]
Abstract
A procedure for extracting the nonlinear component of the stimulus-frequency otoacoustic emission (SFOAE) is described. This nSFOAE measures the amount by which the cochlear response deviates from linear additivity when the input stimulus is doubled in amplitude. When a 4.0-kHz tone was presented alone, the magnitude of the nSFOAE response remained essentially constant throughout the 400-ms duration of the tone; response magnitude did increase monotonically with increasing tone level. When a wideband noise was presented alone, nSFOAE magnitude increased over the initial 100- to 200-ms portion of the 400-ms duration of the noise. When the tone and the wideband noise were presented simultaneously, nSFOAE magnitude decreased momentarily, then increased substantially for about the first 100 ms and then remained strong for the remainder of the presentation. Manipulations of the noise bandwidth revealed that the low-frequency components were primarily responsible for this rising, dynamic response; no rising segment was seen with bandpass or highpass noise. The rising, dynamic nSFOAE response is likely attributable to activation of the medial olivocochlear efferent system. This perstimulatory emission appears to have the potential to provide information about the earliest stages of auditory processing for stimuli commonly used in psychoacoustical tasks.
Collapse
Affiliation(s)
- Kyle P Walsh
- Department of Psychology and Center for Perceptual Systems, 1 University Station A8000, University of Texas, Austin, Texas 78712-0187, USA.
| | | | | |
Collapse
|
40
|
Wojtczak M, Oxenham AJ. On- and off-frequency forward masking by Schroeder-phase complexes. J Assoc Res Otolaryngol 2009; 10:595-607. [PMID: 19626368 DOI: 10.1007/s10162-009-0180-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2009] [Accepted: 06/25/2009] [Indexed: 10/20/2022] Open
Abstract
Forward masking by harmonic tone complexes was measured for on- and off-frequency maskers as a function of masker phase curvature for two masker durations (30 and 200 ms). For the lowest signal frequency (1 kHz), the results matched predictions based on the expected interactions between the phase curvature and amplitude compression of peripheral auditory filtering. For the higher signal frequencies (2 and 6 kHz), the data increasingly departed from predictions in two respects. First, the effects of the masker phase curvature became stronger with increasing masker duration, inconsistent with the expected effects of the fast-acting compression and time-invariant phase response of basilar membrane filtering. Second, significant effects of masker phase curvature were observed for the off-frequency masker using a 6-kHz signal, inconsistent with predictions based on linear processing of stimuli well below the signal frequency. New predictions were generated assuming an additional effect with a longer time constant, consistent with the influence of medial olivocochlear efferent activation on otoacoustic emissions in humans. Reasonable agreement between the predicted and the measured effects suggests that efferent activation is a potential candidate mechanism to explain certain spectro-temporal masking effects in human hearing.
Collapse
Affiliation(s)
- Magdalena Wojtczak
- Department of Psychology, University of Minnesota, 75 East River Rd, Minneapolis, MN, 55455, USA.
| | | |
Collapse
|
41
|
Jennings SG, Strickland EA, Heinz MG. Precursor effects on behavioral estimates of frequency selectivity and gain in forward masking. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2009; 125:2172-81. [PMID: 19354393 PMCID: PMC2736734 DOI: 10.1121/1.3081383] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2008] [Revised: 11/19/2008] [Accepted: 01/13/2009] [Indexed: 05/19/2023]
Abstract
The experiments presented in this paper explore the hypothesis that cochlear gain is reduced, in a frequency-specific manner, over the course of a sound (called a "precursor") which was designed to activate the medial olivo-cochlear reflex (MOCR). Psychophysical tuning curves (PTCs) and off-frequency growth of masking (GOM) functions were measured with two precursors. The on-frequency precursor condition, which was hypothesized to activate the MOCR at the signal frequency, produced a PTC with a lower best frequency in all subjects consistent with less gain. This same condition produced a GOM function with less gain and an elevated compression breakpoint. The data were analyzed with two models. The gain-reduction model, which assumed a change in the basilar membrane input-output function, was superior at predicting the data relative to a model of additivity of masking.
Collapse
Affiliation(s)
- Skyler G Jennings
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907, USA.
| | | | | |
Collapse
|
42
|
Keefe DH, Schairer KS, Ellison JC, Fitzpatrick DF, Jesteadt W. Use of stimulus-frequency otoacoustic emissions to investigate efferent and cochlear contributions to temporal overshoot. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2009; 125:1595-604. [PMID: 19275317 PMCID: PMC2677284 DOI: 10.1121/1.3068443] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2008] [Revised: 12/09/2008] [Accepted: 12/09/2008] [Indexed: 05/24/2023]
Abstract
Behavioral threshold for a tone burst presented in a long-duration noise masker decreases as the onset of the tone burst is delayed relative to masker onset. The threshold difference between detection of early- and late-onset tone bursts is called overshoot. Although the underlying mechanisms are unclear, one hypothesis is that overshoot occurs due to efferent suppression of cochlear nonlinearity [von Klitzing, R., and Kohlrausch, A. (1994). J. Acoust. Soc. Am. 95, 2192-2201]. This hypothesis was tested by using overshoot conditions to elicit stimulus-frequency otoacoustic emissions (SFOAEs), which provide a physiological measure of cochlear nonlinearity. SFOAE and behavioral thresholds were estimated using a modified maximum-likelihood yes-no procedure. The masker was a 400-ms "frozen" notched noise. The signal was a 20-ms, 4-kHz tone burst presented at 1 or 200 ms after the noise onset. Behavioral overshoot results replicated previous studies, but no overshoot was observed in SFOAE thresholds. This suggests that either efferent suppression of cochlear nonlinearity is not involved in overshoot, or a SFOAE threshold estimation procedure based on stimuli similar to those used to study behavioral overshoot is not sensitive enough to measure the effect.
Collapse
Affiliation(s)
- Douglas H Keefe
- Boys Town National Research Hospital, Omaha, Nebraska 68131, USA.
| | | | | | | | | |
Collapse
|
43
|
Krull V, Strickland EA. The effect of a precursor on growth of forward masking. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2008; 123:4352-7. [PMID: 18537386 PMCID: PMC2637535 DOI: 10.1121/1.2912440] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/10/2007] [Revised: 03/25/2008] [Accepted: 03/31/2008] [Indexed: 05/19/2023]
Abstract
This study examined the effect of an on-frequency precursor on growth-of-masking (GOM) functions measured using an off-frequency masker. The signal was a 6-ms, 4-kHz tone. A GOM function was measured using a 40-ms, 2.8-kHz tone (the off-frequency masker). GOM functions were then measured with an on-frequency, fixed level precursor presented before the off-frequency masker. The precursor was 50 or 60 dB SPL, and 160 ms in duration. For the 60-dB SPL precursor, a 40-ms duration was also used. Two-line functions were fit to the GOM data to estimate the basilar membrane input-output function. The precursors reduced the gain of the input-output function, and this decrease was graded with precursor level. Both precursor durations had the same effect on gain. Changes in masking following a precursor were larger than would be predicted by additivity of masking. The observed decrease in gain may be consistent with activation of the medial olivocochlear reflex by the precursor.
Collapse
Affiliation(s)
- Vidya Krull
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907-2038, USA
| | | |
Collapse
|
44
|
Scharf B, Reeves A, Giovanetti H. Role of attention in overshoot: frequency certainty versus uncertainty. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2008; 123:1555-1561. [PMID: 18345843 DOI: 10.1121/1.2835436] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Overshoot, the elevation in the threshold for a brief signal that comes on close to masker onset, was measured with signal frequency certain (same frequency on every trial) or uncertain (randomized over trials). In broadband noise, thresholds were higher 2 ms after masker onset than 200 ms later, by 9 dB with frequency certainty, by 6-7 dB with uncertainty. In narrowband noise centered on the signal frequency, thresholds at 2 ms were not elevated with certainty, but were elevated 4-5 dB with uncertainty. Thus, frequency uncertainty leads to less overshoot in broadband noise, to more overshoot in narrowband noise. Reduced overshoot in broadband noise may come about because the masker, given its many frequencies, disrupts focusing at onset as much under certainty as uncertainty. Once the initial disruption dissipates, threshold is lower with certainty so overshoot is greater. In contrast, a narrowband noise with frequencies only near the signal does not disrupt focusing when the signal frequency is known beforehand, so overshoot is absent. When frequency is uncertain, the narrowband noise serves to focus attention on the signal frequency; as this requires time, detection near noise onset is poorer than later on, so overshoot is present.
Collapse
Affiliation(s)
- Bertram Scharf
- Department of Psychology, Northeastern University, Boston, Massachusetts 02115, USA.
| | | | | |
Collapse
|
45
|
Strickland EA. The relationship between precursor level and the temporal effect. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2008; 123:946-54. [PMID: 18247897 PMCID: PMC2637526 DOI: 10.1121/1.2821977] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Previous studies have suggested that temporal effects in masking may be consistent with a decrease in cochlear gain. One paradigm used to show this is to measure the level of a long-duration masker required to just mask a short-duration tone that occurs near masker onset. The temporal effect is revealed when the signal is detected at a lower signal-to-noise ratio following preceding stimulation (either an extension of the masker or a separate precursor). The present study examined whether this effect depends on precursor level. The signal was a 10-ms, 4-kHz tone. The masker was 200 ms. A fixed-level precursor had the same frequency characteristics as the masker, and was 205 ms. The masker and precursor had either no notch or a wide notch about the signal frequency. For a given precursor level, the growth of masker level with signal level was determined. These data were used to estimate input-output functions. The results are consistent with a graded decrease in gain at the signal frequency when there is no notch in the masker and precursor, and a graded decrease in suppression when there is a large notch. These results could be consistent with the action of the medial olivocochlear reflex.
Collapse
Affiliation(s)
- Elizabeth A Strickland
- Department of Speech, Language, and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907-2038, USA.
| |
Collapse
|
46
|
Strickland EA, Krishnan LA. The temporal effect in listeners with mild to moderate cochlear hearing impairment. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2005; 118:3211-7. [PMID: 16334697 DOI: 10.1121/1.2074787] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
This study examines the relationship between a temporal masking effect and cochlear hearing impairment. The threshold level of a long-duration broadband masker needed to mask a short-duration tonal signal was measured for signals presented 2 ms (short-delay) or 202 ms (long-delay condition) after masker onset. The difference between these thresholds is the temporal effect. In two previous studies with normal-hearing listeners, estimates of gain of the cochlear active process derived from such data suggested a decrease in gain during the course of the masker. This hypothesis was further examined in the present study by testing listeners with mild to moderate cochlear hearing impairment. Results are consistent with a decrease in gain in the short-delay condition with increasing hearing impairment, and also less change in gain with increasing hearing impairment.
Collapse
Affiliation(s)
- Elizabeth A Strickland
- Department of Speech, Language and Hearing Sciences, Purdue University, West Lafayette, Indiana 47907, USA.
| | | |
Collapse
|