1
|
Hodaei M, Mandelis A. Quantitative osteoporosis diagnosis of porous cancellous bone using poroelastodynamic modal analysis. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2023; 154:3101-3124. [PMID: 37966333 DOI: 10.1121/10.0022351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Accepted: 10/18/2023] [Indexed: 11/16/2023]
Abstract
Osteoporosis is a skeletal disease characterized by reduced bone mass and microarchitectural deterioration, leading to increased fragility. This study presents a novel three-dimensional poroelastodynamic model for analyzing cancellous bone free vibration responses. The model incorporates the Navier-Stokes equations of linear elasticity and the Biot theory of porous media, allowing the investigation of osteoporosis-related changes. The analysis considers parameters like porosity, density, elasticity, Poisson ratio, and viscosity of bone marrow within the porous medium. Our findings indicate that natural frequencies of cancellous bone play a crucial role in osteoporosis prediction. By incorporating experimental data from 12 mouse femurs, we unveil insights into osteoporosis prediction. Increased porosity reduces bone stiffness, lowering natural frequencies. However, it also increases bone mass loss relative to stiffness, leading to higher frequencies. Therefore, the natural frequencies of osteoporotic bone are always higher than the natural frequencies of normal bone. Additionally, an increase in bone marrow within the pores, while increasing damping effects, also increases natural frequencies, which is another indication of osteoporosis growth in bone. The presence of bone marrow within the pores further influences natural frequencies, providing additional insights into osteoporosis growth. Thinner and smaller bones are found to be more susceptible to osteoporosis compared to larger and bigger bones due to their higher natural frequencies at equivalent porosity levels.
Collapse
Affiliation(s)
- Mohammad Hodaei
- Center For Advanced Diffusion-Wave and Photoacoustic Technologies (CADIPT), Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario M5S 3G8, Canada
- Institute For Advanced Non-Destructive and Non-Invasive Diagnostic Technologies (IANDIT), Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario M5S 3G8, Canada
| | - Andreas Mandelis
- Center For Advanced Diffusion-Wave and Photoacoustic Technologies (CADIPT), Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario M5S 3G8, Canada
- Institute For Advanced Non-Destructive and Non-Invasive Diagnostic Technologies (IANDIT), Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario M5S 3G8, Canada
| |
Collapse
|
2
|
Scarpa J, Parazynski S, Strangman G. Space exploration as a catalyst for medical innovations. Front Med (Lausanne) 2023; 10:1226531. [PMID: 37538310 PMCID: PMC10395101 DOI: 10.3389/fmed.2023.1226531] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Accepted: 06/30/2023] [Indexed: 08/05/2023] Open
Abstract
Aerospace research has a long history of developing technologies with industry-changing applications and recent history is no exception. The expansion of commercial spaceflight and the upcoming exploration-class missions to the Moon and Mars are expected to accelerate this process even more. The resulting portable, wearable, contactless, and regenerable medical technologies are not only the future of healthcare in deep space but also the future of healthcare here on Earth. These multi-dimensional and integrative technologies are non-invasive, easily-deployable, low-footprint devices that have the ability to facilitate rapid detection, diagnosis, monitoring, and treatment of a variety of conditions, and to provide decision-making and performance support. Therefore, they are primed for applications in low-resource and remote environments, facilitating the extension of quality care delivery to all patients in all communities and empowering non-specialists to intervene early and safely in order to optimize patient-centered outcomes. Additionally, these technologies have the potential to advance care delivery in tertiary care centers by improving transitions of care, providing holistic patient data, and supporting clinician wellness and performance. The requirements of space exploration have created a number of paradigm-altering medical technologies that are primed to revitalize and elevate our standard of care here on Earth.
Collapse
Affiliation(s)
- Julia Scarpa
- Department of Anesthesiology, New York Presbyterian Hospital, Weill Cornell Medical Center, New York, NY, United States
| | | | - Gary Strangman
- Department of Psychiatry, Harvard Medical School, Boston, MA, United States
- Translational Research Institute for Space Health, Baylor College of Medicine, Houston, TX, United States
| |
Collapse
|
3
|
Design and simulation of a 2-D array flexible ultrasound transducer system for tissue characterization – A pilot study. MEDICINE IN NOVEL TECHNOLOGY AND DEVICES 2022. [DOI: 10.1016/j.medntd.2021.100106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
|
4
|
Wear KA. Mechanisms of Interaction of Ultrasound With Cancellous Bone: A Review. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:454-482. [PMID: 31634127 PMCID: PMC7050438 DOI: 10.1109/tuffc.2019.2947755] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Ultrasound is now a clinically accepted modality in the management of osteoporosis. The most common commercial clinical devices assess fracture risk from measurements of attenuation and sound speed in cancellous bone. This review discusses fundamental mechanisms underlying the interaction between ultrasound and cancellous bone. Because of its two-phase structure (mineralized trabecular network embedded in soft tissue-marrow), its anisotropy, and its inhomogeneity, cancellous bone is more difficult to characterize than most soft tissues. Experimental data for the dependencies of attenuation, sound speed, dispersion, and scattering on ultrasound frequency, bone mineral density, composition, microstructure, and mechanical properties are presented. The relative roles of absorption, scattering, and phase cancellation in determining attenuation measurements in vitro and in vivo are delineated. Common speed of sound metrics, which entail measurements of transit times of pulse leading edges (to avoid multipath interference), are greatly influenced by attenuation, dispersion, and system properties, including center frequency and bandwidth. However, a theoretical model has been shown to be effective for correction for these confounding factors in vitro and in vivo. Theoretical and phantom models are presented to elucidate why cancellous bone exhibits negative dispersion, unlike soft tissue, which exhibits positive dispersion. Signal processing methods are presented for separating "fast" and "slow" waves (predicted by poroelasticity theory and supported in cancellous bone) even when the two waves overlap in time and frequency domains. Models to explain dependencies of scattering on frequency and mean trabecular thickness are presented and compared with measurements. Anisotropy, the effect of the fluid filler medium (marrow in vivo or water in vitro), phantoms, computational modeling of ultrasound propagation, acoustic microscopy, and nonlinear properties in cancellous bone are also discussed.
Collapse
|
5
|
Wear KA. Nonlinear attenuation and dispersion in human calcaneus in vitro: statistical validation and relationships to microarchitecture. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2015; 137:1126-1133. [PMID: 25786928 PMCID: PMC9204557 DOI: 10.1121/1.4908310] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Through-transmission measurements were performed on 30 human calcaneus samples in vitro. Nonlinear attenuation and dispersion measurements were investigated by estimating 95% confidence intervals of coefficients of polynomial expansions of log magnitude and phase of transmission coefficients. Bone mineral density (BMD) was measured with dual x-ray absorptiometry. Microarchitecture was measured with microcomputed tomography. Statistically significant nonlinear attenuation and nonzero dispersion were confirmed for a clinical bandwidth of 300-750 kHz in 40%-43% of bone samples. The mean linear coefficient for attenuation was 10.3 dB/cm MHz [95% confidence interval (CI): 9.0-11.6 dB/cm MHz]. The mean quadratic coefficient for attenuation was 1.6 dB/cm MHz(2) (95% CI: 0.4-2.8 dB/cm MHz(2)). Nonlinear attenuation provided little information regarding BMD or microarchitecture. The quadratic coefficient for phase (which is related to dispersion) showed moderate correlations with BMD (r = -0.65; 95% CI: -0.82 to -0.36), bone surface-to-volume ratio (r = 0.47; 95% CI: 0.12-0.72) and trabecular thickness (r = -0.40; 95% CI: -0.67 to -0.03). Dispersion was proportional to bone volume fraction raised to an exponent of 2.1 ± 0.2, which is similar to the value for parallel nylon-wire phantoms (2.4 ± 0.2) and supports a multiple-scattering model for dispersion.
Collapse
Affiliation(s)
- Keith A Wear
- United States Food and Drug Administration, Center for Devices and Radiological Health, Silver Spring, Maryland 20993
| |
Collapse
|
6
|
Lashkari B, Yang L, Mandelis A. The application of backscattered ultrasound and photoacoustic signals for assessment of bone collagen and mineral contents. Quant Imaging Med Surg 2015; 5:46-56. [PMID: 25694953 DOI: 10.3978/j.issn.2223-4292.2014.11.11] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2014] [Accepted: 10/10/2014] [Indexed: 01/22/2023]
Abstract
BACKGROUND This study examines the backscattered ultrasound (US) and back-propagating photoacoustic (PA) signals from trabecular bones, and their variations with reduction in bone minerals and collagen content. While the collagen status is directly related to the strength of the bone, diagnosis of its condition using US remains a challenge. METHODS For both PA and US methods, coded-excitation signals and matched filtering were utilized to provide high sensitivity of the detected signal. The optical source was a 805-nm CW laser and signals were detected employing a 2.2-MHz ultrasonic transducer. Bone decalcification and decollagenization were induced with mild ethylenediaminetetraacetic acid (EDTA) and sodium hypochlorite solutions, respectively. RESULTS The PA and US signals were measured on cattle bones, and apparent integrated backscatter/back-propagating (AIB) parameters were compared before and after demineralization and decollagenization. CONCLUSIONS The results show that both PA and US are sensitive to mineral changes. In addition, PA is also sensitive to changes in the collagen content of the bone, but US is not significantly sensitive to these changes.
Collapse
Affiliation(s)
- Bahman Lashkari
- 1 Center for Advanced Diffusion-Wave Technologies (CADIFT), Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario, Canada ; 2 School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054, China
| | - Lifeng Yang
- 1 Center for Advanced Diffusion-Wave Technologies (CADIFT), Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario, Canada ; 2 School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054, China
| | - Andreas Mandelis
- 1 Center for Advanced Diffusion-Wave Technologies (CADIFT), Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario, Canada ; 2 School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054, China
| |
Collapse
|
7
|
Slatkovska L, Beyene J, Alibhai SMH, Wong Q, Sohail QZ, Cheung AM. Effect of whole-body vibration on calcaneal quantitative ultrasound measurements in postmenopausal women: a randomized controlled trial. Calcif Tissue Int 2014; 95:547-56. [PMID: 25388526 DOI: 10.1007/s00223-014-9920-1] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2014] [Accepted: 10/14/2014] [Indexed: 12/01/2022]
Abstract
The purpose of this study was to examine the effect of whole-body vibration (WBV) on calcaneal quantitative ultrasound (QUS) measurements; which has rarely been examined. We conducted a single-centre, 12-month, randomized controlled trial. 202 postmenopausal women with BMD T score between -1.0 and -2.5, not receiving bone medications, were asked to stand on a 0.3 g WBV platform oscillating at either 90- or 30-Hz for 20 consecutive minutes daily, or to serve as controls. Calcium and vitamin D was provided to all participants. Calcaneal broadband attenuation (BUA), speed of sound, and QUS index were obtained as pre-specified secondary endpoints at baseline and 12 months by using a Hologic Sahara Clinical Bone Sonometer. 12-months of WBV did not improve QUS parameters in any of our analyses. While most of our analyses showed no statistical differences between the WBV groups and the control group, mean calcaneal BUA decreased in the 90-Hz (-0.4 [95% CI -1.9 to 1.2] dB MHz(-1)) and 30-Hz (-0.7 [95% CI -2.3 to 0.8] dB MHz(-1)) WBV groups and increased in the control group (1.3 [95% CI 0.0-2.6] dB MHz(-1)). Decreases in BUA in the 90-, 30-Hz or combined WBV groups were statistically different from the control group in a few of the analyses including all randomized participants, as well as in analyses excluding participants who had missing QUS measurement and those who initiated hormone therapy or were <80% adherent. Although there are consistent trends, not all analyses reached statistical significance. 0.3 g WBV at 90 or 30 Hz prescribed for 20 min daily for 12 months did not improve any QUS parameters, but instead resulted in a statistically significant, yet small, decrease in calcaneal BUA in postmenopausal women in several analyses. These unexpected findings require further investigation.
Collapse
Affiliation(s)
- Lubomira Slatkovska
- Osteoporosis Program, University Health Network/Mount Sinai Hospital, 200 Elizabeth Street, 7 Eaton North, Room 221, Toronto, ON, Canada
| | | | | | | | | | | |
Collapse
|
8
|
Lin W, Serra-Hsu F, Cheng J, Qin YX. Frequency specific ultrasound attenuation is sensitive to trabecular bone structure. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:2198-2207. [PMID: 22975035 PMCID: PMC3511662 DOI: 10.1016/j.ultrasmedbio.2012.07.020] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2012] [Revised: 07/19/2012] [Accepted: 07/24/2012] [Indexed: 05/28/2023]
Abstract
This study investigated the efficacy of frequency modulated ultrasound attenuation in the assessment of the trabecular structural properties. Four frequency modulated signals were created to represent four frequency bands centered at 500 kHz, 900 kHz, 1.3 MHz and 1.7 MHz with the bandwidth of 400 kHz. Five 1-cm trabecular cubes were harvested from fresh bovine distal femur. The cubes underwent four steps of demineralization process to expand the sample size to 25 with the greater variations of the structural properties for the better correlation study. Pearson correlation study was performed between the ultrasound attenuation in four frequency bands and the trabecular structural properties. The results showed that correlations of frequency modulated ultrasound attenuation to the trabecular structural properties are dependent on frequency bands. The attenuation in proximal-distal orientation had the highest correlation to BV/TV (R(2) = 0.73, p < 0.001) and trabecular thickness (R(2) = 0.50, p < 0.001) at the frequency band centered at 1.7 MHz. It was equivalent in the four frequency bands in correlation to the trabecular number (average R(2) = 0.80, p < 0.001) and to the trabecular separation (average R(2) = 0.83, p < 0.001). The attenuation in anterio-posterial orientation had the highest correlation to BV/TV (R(2) = 0.80, p < 0.001) and trabecular thickness (R(2) = 0.71, p < 0.001) at the frequency band centered at 1.3 MHz. The attenuation in the first frequency band was the most sensitive to the trabecular number (R(2) = 0.71, p < 0.001) and trabecular separation (R(2) = 0.80, p < 0.001). No significant correlation was observed for the attenuation in medial-lateral orientation across the four frequency bands.
Collapse
Affiliation(s)
- Wei Lin
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794-5281, USA.
| | | | | | | |
Collapse
|
9
|
Cardoso L, Cowin SC. Role of structural anisotropy of biological tissues in poroelastic wave propagation. MECHANICS OF MATERIALS : AN INTERNATIONAL JOURNAL 2012; 44:174-188. [PMID: 22162897 PMCID: PMC3233242 DOI: 10.1016/j.mechmat.2011.08.007] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Ultrasound waves have a broad range of clinical applications as a non-destructive testing approach in imaging and in the diagnoses of medical conditions. Generally, biological tissues are modeled as an homogenized equivalent medium with an apparent density through which a single wave propagates. Only the first wave arriving at the ultrasound probe is used for the measurement of the speed of sound. However, the existence of a second wave in tissues such as cancellous bone has been reported and its existence is an unequivocal signature of Biot type poroelastic media. To account for the fact that ultrasound is sensitive to microarchitecture as well as density, a fabric-dependent anisotropic poroelastic ultrasound (PEU) propagation theory was recently developed. Key to this development was the inclusion of the fabric tensor - a quantitative stereological measure of the degree of structural anisotropy of bone - into the linear poroelasticity theory. In the present study, this framework is extended to the propagation of waves in several soft and hard tissues. It was found that collagen fibers in soft tissues and the mineralized matrix in hard tissues are responsible for the anisotropy of the solid tissue constituent through the fabric tensor in the model.
Collapse
Affiliation(s)
- Luis Cardoso
- The Department of Biomedical Engineering, The City University of New York, New York, NY 10031
| | | |
Collapse
|
10
|
Cheng J, Serra-Hsu F, Tian Y, Lin W, Qin YX. Effects of phase cancellation and receiver aperture size on broadband ultrasonic attenuation for trabecular bone in vitro. ULTRASOUND IN MEDICINE & BIOLOGY 2011; 37:2116-25. [PMID: 22033134 PMCID: PMC3223273 DOI: 10.1016/j.ultrasmedbio.2011.08.009] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2011] [Revised: 07/15/2011] [Accepted: 08/10/2011] [Indexed: 05/25/2023]
Abstract
Phase cancellation in ultrasound due to large receiver size has been proposed as a contributing factor to the inaccuracy of estimating broadband ultrasound attenuation (BUA), which is used to characterize bone quality. Transducers with aperture size ranging from 2 to 5 mm have been used in previous attempts to study the effect of phase cancellation. However, these receivers themselves are susceptible to phase cancellation because aperture size is close to one center wavelength (about 3 mm at 500 KHz in water). This study uses an ultra small receiver (aperture size: 0.2 mm) in conjunction with a newly developed two-dimensional (2-D) synthetic array system to investigate the effects of phase cancellation and receiver aperture size on BUA estimations of bone tissue. In vitro ultrasound measurements were conducted on 54 trabecular bone samples (harvested from sheep femurs) in a confocal configuration with a focused transmitter and synthesized focused receivers of different aperture sizes. Phase sensitive (PS) and phase insensitive (PI) detections were performed. The results show that phase cancellation does have a significant effect on BUA. The normalized BUA (nBUA) with PS is 8.1% higher than PI nBUA while PI BUA is well correlated with PS BUA. Receiver aperture size also influences the BUA reading for both PI and PS detection and smaller receiver aperture tends to result in higher BUA readings. The results also indicate that the receiver aperture size used in the confocal configuration with PI detection should at least equal the aperture of the transmitter to capture most of the energy redistributed by the interference and diffraction from the trabecular bone.
Collapse
Affiliation(s)
| | | | | | | | - Yi-Xian Qin
- Address correspondence to: Yi-Xian Qin, Bioengineering Building RM 215, Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794-5281.
| |
Collapse
|
11
|
Serra-Hsu F, Cheng J, Lynch T, Qin YX. Evaluation of a pulsed phase-locked loop system for noninvasive tracking of bone deformation under loading with finite element and strain analysis. Physiol Meas 2011; 32:1301-13. [PMID: 21765205 PMCID: PMC4961073 DOI: 10.1088/0967-3334/32/8/019] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Ultrasound has been widely used to nondestructively evaluate various materials, including biological tissues. Quantitative ultrasound has been used to assess bone quality and fracture risk. A pulsed phase-locked loop (PPLL) method has been proven for very sensitive tracking of ultrasound time-of-flight (TOF) changes. The objective of this work was to determine if the PPLL TOF tracking is sensitive to bone deformation changes during loading. The ability to noninvasively detect bone deformations has many implications, including assessment of bone strength and more accurate osteoporosis diagnostics and fracture risk prediction using a measure of bone mechanical quality. Fresh sheep femur cortical bone shell samples were instrumented with three 3-element rosette strain gauges and then tested under mechanical compression with eight loading levels using an MTS machine. Samples were divided into two groups based on internal marrow cavity content: with original marrow, or replaced with water. During compressive loading ultrasound waves were measured through acoustic transmission across the mid-diaphysis of bone. Finite element analysis (FEA) was used to describe ultrasound propagation path length changes under loading based on µCT-determined bone geometry. The results indicated that PPLL output correlates well to measured axial strain, with R(2) values of 0.70 ± 0.27 and 0.62 ± 0.29 for the marrow and water groups, respectively. The PPLL output correlates better with the ultrasound path length changes extracted from FEA. For the two validated FEA tests, correlation was improved to R(2) = 0.993 and R(2) = 0.879 through cortical path, from 0.815 and 0.794 via marrow path, respectively. This study shows that PPLL readings are sensitive to displacement changes during external bone loading, which may have potential to noninvasively assess bone strain and tissue mechanical properties.
Collapse
Affiliation(s)
- Frederick Serra-Hsu
- Orthopaedic Bioengineering Research Lab, Department of Biomedical Engineering, State University of New York at Stony Brook, Stony Brook, NY 11794-5281, USA
| | - Jiqi Cheng
- Orthopaedic Bioengineering Research Lab, Department of Biomedical Engineering, State University of New York at Stony Brook, Stony Brook, NY 11794-5281, USA
| | - Ted Lynch
- Luna Innovations, 1 Riverside Circle, Suite 400, Roanoke, VA 24016-4962, USA
| | - Yi-Xian Qin
- Orthopaedic Bioengineering Research Lab, Department of Biomedical Engineering, State University of New York at Stony Brook, Stony Brook, NY 11794-5281, USA
| |
Collapse
|
12
|
Cheng J, Lin W, Qin YX. Extension of the distributed point source method for ultrasonic field modeling. ULTRASONICS 2011; 51:571-80. [PMID: 21269654 PMCID: PMC3051007 DOI: 10.1016/j.ultras.2010.12.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2010] [Revised: 12/14/2010] [Accepted: 12/17/2010] [Indexed: 05/07/2023]
Abstract
The distributed point source method (DPSM) was recently proposed for ultrasonic field modeling and other applications. This method uses distributed point sources, placed slightly behind transducer surface, to model the ultrasound field. The acoustic strength of each point source is obtained through matrix inversion that requires the number of target points on the transducer surface to be equal to the number of point sources. In this work, DPSM was extended and further developed to overcome the limitations of the original method and provide a solid mathematical explanation of the physical principle behind the method. With the extension, the acoustic strength of the point sources was calculated as the solution to the least squares minimization problem instead of using direct matrix inversion. As numerical examples, the ultrasound fields of circular and rectangular transducers were calculated using the extended and original DPSMs which were then systematically compared with the results calculated using the theoretical solution and the exact spatial impulse response method. The numerical results showed the extended method can model ultrasonic fields accurately without the scaling step required by the original method. The extended method has potential applications in ultrasonic field modeling, tissue characterization, nondestructive testing, and ultrasound system optimization.
Collapse
Affiliation(s)
- Jiqi Cheng
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794, USA
| | - Wei Lin
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794, USA
| | - Yi-Xian Qin
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794, USA
| |
Collapse
|
13
|
Cardoso L, Cowin SC. Fabric dependence of quasi-waves in anisotropic porous media. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2011; 129:3302-16. [PMID: 21568431 PMCID: PMC3115277 DOI: 10.1121/1.3557032] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2010] [Revised: 01/14/2011] [Accepted: 01/19/2011] [Indexed: 05/20/2023]
Abstract
Assessment of bone loss and osteoporosis by ultrasound systems is based on the speed of sound and broadband ultrasound attenuation of a single wave. However, the existence of a second wave in cancellous bone has been reported and its existence is an unequivocal signature of poroelastic media. To account for the fact that ultrasound is sensitive to microarchitecture as well as bone mineral density (BMD), a fabric-dependent anisotropic poroelastic wave propagation theory was recently developed for pure wave modes propagating along a plane of symmetry in an anisotropic medium. Key to this development was the inclusion of the fabric tensor--a quantitative stereological measure of the degree of structural anisotropy of bone--into the linear poroelasticity theory. In the present study, this framework is extended to the propagation of mixed wave modes along an arbitrary direction in anisotropic porous media called quasi-waves. It was found that differences between phase and group velocities are due to the anisotropy of the bone microarchitecture, and that the experimental wave velocities are more accurately predicted by the poroelastic model when the fabric tensor variable is taken into account. This poroelastic wave propagation theory represents an alternative for bone quality assessment beyond BMD.
Collapse
Affiliation(s)
- Luis Cardoso
- The Department of Biomedical Engineering, The City University of New York, New York, New York 10031, USA.
| | | |
Collapse
|