1
|
Guérit F, Middlebrooks JC, Gransier R, Richardson ML, Wouters J, Carlyon RP. Exploring the Use of Interleaved Stimuli to Measure Cochlear-Implant Excitation Patterns. J Assoc Res Otolaryngol 2024; 25:201-213. [PMID: 38459245 PMCID: PMC11018570 DOI: 10.1007/s10162-024-00937-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Accepted: 02/15/2024] [Indexed: 03/10/2024] Open
Abstract
PURPOSE Attempts to use current-focussing strategies with cochlear implants (CI) to reduce neural spread-of-excitation have met with only mixed success in human studies, in contrast to promising results in animal studies. Although this discrepancy could stem from between-species anatomical and aetiological differences, the masking experiments used in human studies may be insufficiently sensitive to differences in excitation-pattern width. METHODS We used an interleaved-masking method to measure psychophysical excitation patterns in seven participants with four masker stimulation configurations: monopolar (MP), partial tripolar (pTP), a wider partial tripolar (pTP + 2), and, importantly, a condition (RP + 2) designed to produce a broader excitation pattern than MP. The probe was always in partial-tripolar configuration. RESULTS We found a significant effect of stimulation configuration on both the amount of on-site masking (mask and probe on same electrode; an indirect indicator of sharpness) and the difference between off-site and on-site masking. Differences were driven solely by RP + 2 producing a broader excitation pattern than the other configurations, whereas monopolar and the two current-focussing configurations did not statistically differ from each other. CONCLUSION A method that is sensitive enough to reveal a modest broadening in RP + 2 showed no evidence for sharpening with focussed stimulation. We also showed that although voltage recordings from the implant accurately predicted a broadening of the psychophysical excitation patterns with RP + 2, they wrongly predicted a strong sharpening with pTP + 2. We additionally argue, based on our recent research, that the interleaved-masking method can usefully be applied to non-human species and objective measures of CI excitation patterns.
Collapse
Affiliation(s)
- François Guérit
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England.
| | - John C Middlebrooks
- Department of Otolaryngology, University of California at Irvine, Irvine, CA, USA
- Department of Neurobiology and Behavior, University of California at Irvine, Irvine, CA, USA
- Department of Biomedical Engineering, University of California at Irvine, Irvine, CA, USA
| | - Robin Gransier
- Department of Neurosciences, ExpORL KU Leuven, Leuven, Belgium
- Leuven Brain Institute KU Leuven, Leuven, Belgium
| | - Matthew L Richardson
- Department of Otolaryngology, University of California at Irvine, Irvine, CA, USA
| | - Jan Wouters
- Department of Neurosciences, ExpORL KU Leuven, Leuven, Belgium
- Leuven Brain Institute KU Leuven, Leuven, Belgium
| | - Robert P Carlyon
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England
| |
Collapse
|
2
|
Heitkötter FS, Krämer BA, Spiekermann CO, Beule AG, Rudack C. Perception of Specific Musical Attributes in Dependence of the Insertion Depth of Cochlear Implant Electrodes Using the Montreal Battery of Evaluation of Amusia. Otol Neurotol 2024; 45:e214-e220. [PMID: 38238925 DOI: 10.1097/mao.0000000000004087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2024]
Abstract
HYPOTHESIS The insertion angle of the electrode array has an influence on the perception of different musical features. BACKGROUND A deeper insertion of the electrodes is associated with a greater coverage of the cochlea with possible stimulus locations. This could lead to an improved or extended perception of pitches and pitch changes as well as to a better perception of contours in musical pieces. METHODS A Montreal Battery of Evaluation of Amusia test battery was conducted with a collective of 19 cochlear implant (CI) users and 9 normal-hearing subjects. For the CI users, the insertion angles of the intracochlear electrode arrays were calculated using Otoplan software. RESULTS Compared with normal-hearing users, CI users performed worse in the detection of melodic features of music. CI users performed better with temporal features than with melodic features. An influence of the insertion depth of the electrodes on the results of the Montreal Battery of Evaluation of Amusia could be proven neither for Cochlear nor for MED-EL CI users. CONCLUSION Deeper insertion of electrode arrays may only better approximate the spatial-frequency map. Alone, it does not have an effect on better detection and identification of pitch and tonality and, consequently, better perception of musical attributes. Anatomy-based calculation of electrode locations and matching to characteristic frequencies will be sought in subsequent studies.
Collapse
Affiliation(s)
- Felix S Heitkötter
- Department of Experimental Audiology, University Clinic for Otorhinolaryngology Münster of the Westfälische Wilhelms-University Münster, Münster, Germany
| | | | | | | | | |
Collapse
|
3
|
Guérit F, Middlebrooks JC, Richardson ML, Arneja A, Harland AJ, Gransier R, Wouters J, Carlyon RP. Tonotopic Selectivity in Cats and Humans: Electrophysiology and Psychophysics. J Assoc Res Otolaryngol 2022; 23:513-534. [PMID: 35697952 PMCID: PMC9437197 DOI: 10.1007/s10162-022-00851-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Accepted: 05/02/2022] [Indexed: 01/06/2023] Open
Abstract
We describe a scalp-recorded measure of tonotopic selectivity, the "cortical onset response" (COR) and compare the results between humans and cats. The COR results, in turn, were compared with psychophysical masked-detection thresholds obtained using similar stimuli and obtained from both species. The COR consisted of averaged responses elicited by 50-ms tone-burst probes presented at 1-s intervals against a continuous noise masker. The noise masker had a bandwidth of 1 or 1/8th octave, geometrically centred on 4000 Hz for humans and on 8000 Hz for cats. The probe frequency was either - 0.5, - 0.25, 0, 0.25 or 0.5 octaves re the masker centre frequency. The COR was larger for probe frequencies more distant from the centre frequency of the masker, and this effect was greater for the 1/8th-octave than for the 1-octave masker. This pattern broadly reflected the masked excitation patterns obtained psychophysically with similar stimuli in both species. However, the positive signal-to-noise ratio used to obtain reliable COR measures meant that some aspects of the data differed from those obtained psychophysically, in a way that could be partly explained by the upward spread of the probe's excitation pattern. Our psychophysical measurements also showed that the auditory filter width obtained at 8000 Hz using notched-noise maskers was slightly wider in cat than previous measures from humans. We argue that although conclusions from COR measures differ in some ways from conclusions based on psychophysics, the COR measures provide an objective, noninvasive, valid measure of tonotopic selectivity that does not require training and that may be applied to acoustic and cochlear-implant experiments in humans and laboratory animals.
Collapse
Affiliation(s)
- Francois Guérit
- grid.5335.00000000121885934Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England
| | - John C. Middlebrooks
- grid.266093.80000 0001 0668 7243Department of Otolaryngology, University of California at Irvine, Irvine, CA USA
- grid.266093.80000 0001 0668 7243Department of Neurobiology and Behavior, University of California at Irvine, Irvine, CA USA
- grid.266093.80000 0001 0668 7243Department of Cognitive Sciences, University of California at Irvine, Irvine, CA USA
- grid.266093.80000 0001 0668 7243Department of Biomedical Engineering, University of California at Irvine, Irvine, CA USA
| | - Matthew L. Richardson
- grid.266093.80000 0001 0668 7243Department of Otolaryngology, University of California at Irvine, Irvine, CA USA
| | - Akshat Arneja
- grid.266093.80000 0001 0668 7243Department of Cognitive Sciences, University of California at Irvine, Irvine, CA USA
| | - Andrew J. Harland
- grid.5335.00000000121885934Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England
| | - Robin Gransier
- Dept. of Neurosciences, ExpORL, Leuven, Louvain, KU Belgium
| | - Jan Wouters
- Dept. of Neurosciences, ExpORL, Leuven, Louvain, KU Belgium
| | - Robert P. Carlyon
- grid.5335.00000000121885934Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England
| |
Collapse
|
4
|
Carlyon RP, Goehring T. Cochlear Implant Research and Development in the Twenty-first Century: A Critical Update. J Assoc Res Otolaryngol 2021; 22:481-508. [PMID: 34432222 PMCID: PMC8476711 DOI: 10.1007/s10162-021-00811-5] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Accepted: 08/02/2021] [Indexed: 12/22/2022] Open
Abstract
Cochlear implants (CIs) are the world's most successful sensory prosthesis and have been the subject of intense research and development in recent decades. We critically review the progress in CI research, and its success in improving patient outcomes, from the turn of the century to the present day. The review focuses on the processing, stimulation, and audiological methods that have been used to try to improve speech perception by human CI listeners, and on fundamental new insights in the response of the auditory system to electrical stimulation. The introduction of directional microphones and of new noise reduction and pre-processing algorithms has produced robust and sometimes substantial improvements. Novel speech-processing algorithms, the use of current-focusing methods, and individualised (patient-by-patient) deactivation of subsets of electrodes have produced more modest improvements. We argue that incremental advances have and will continue to be made, that collectively these may substantially improve patient outcomes, but that the modest size of each individual advance will require greater attention to experimental design and power. We also briefly discuss the potential and limitations of promising technologies that are currently being developed in animal models, and suggest strategies for researchers to collectively maximise the potential of CIs to improve hearing in a wide range of listening situations.
Collapse
Affiliation(s)
- Robert P Carlyon
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, CB2 7EF, UK.
| | - Tobias Goehring
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, CB2 7EF, UK
| |
Collapse
|
5
|
Carlyon RP, Guérit F, Deeks JM, Harland A, Gransier R, Wouters J, de Rijk SR, Bance M. Using Interleaved Stimulation to Measure the Size and Selectivity of the Sustained Phase-Locked Neural Response to Cochlear Implant Stimulation. J Assoc Res Otolaryngol 2021; 22:141-159. [PMID: 33492562 PMCID: PMC7943679 DOI: 10.1007/s10162-020-00783-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Accepted: 12/21/2020] [Indexed: 02/08/2023] Open
Abstract
We measured the sustained neural response to electrical stimulation by a cochlear implant (CI). To do so, we interleaved two stimuli with frequencies F1 and F2 Hz and recorded a neural distortion response (NDR) at F2-F1 Hz. We show that, because any one time point contains only the F1 or F2 stimulus, the instantaneous nonlinearities typical of electrical artefact should not produce distortion at this frequency. However, if the stimulus is smoothed, such as by charge integration at the nerve membrane, subsequent (neural) nonlinearities can produce a component at F2-F1 Hz. We stimulated a single CI electrode with interleaved sinusoids or interleaved amplitude-modulated pulse trains such that F2 = 1.5F1, and found no evidence for an NDR when F2-F1 was between 90 and 120 Hz. However, interleaved amplitude-modulated pulse trains with F2-F1~40 Hz revealed a substantial NDR with a group delay of about 45 ms, consistent with a thalamic and/or cortical response. The NDR could be measured even from recording electrodes adjacent to the implant and at the highest pulse rates (> 4000 pps) used clinically. We then measured the selectivity of this sustained response by presenting F1 and F2 to different electrodes and at different between-electrode distances. This revealed a broad tuning that, we argue, reflects the overlap between the excitation elicited by the two electrodes. Our results also provide a glimpse of the neural nonlinearity in the auditory system, unaffected by the biomechanical cochlear nonlinearities that accompany acoustic stimulation. Several potential clinical applications of our findings are discussed.
Collapse
Affiliation(s)
- Robert P Carlyon
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, 15 Chaucer Rd, Cambridge, CB2 7EF, England.
| | - François Guérit
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, 15 Chaucer Rd, Cambridge, CB2 7EF, England
| | - John M Deeks
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, 15 Chaucer Rd, Cambridge, CB2 7EF, England
| | - Andrew Harland
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, 15 Chaucer Rd, Cambridge, CB2 7EF, England
| | - Robin Gransier
- Dept. of Neurosciences, ExpORL, KU Leuven, Herestraat 49 box 721, 3000, Leuven, Belgium
| | - Jan Wouters
- Dept. of Neurosciences, ExpORL, KU Leuven, Herestraat 49 box 721, 3000, Leuven, Belgium
| | - Simone R de Rijk
- Cambridge Hearing Group, Dept. Clinical Neurosciences, University of Cambridge, Cambridge Biomedical Campus, Cambridge, CB2 0QQ, England
| | - Manohar Bance
- Cambridge Hearing Group, Dept. Clinical Neurosciences, University of Cambridge, Cambridge Biomedical Campus, Cambridge, CB2 0QQ, England
| |
Collapse
|
6
|
McKay CM. Applications of Phenomenological Loudness Models to Cochlear Implants. Front Psychol 2021; 11:611517. [PMID: 33519626 PMCID: PMC7838155 DOI: 10.3389/fpsyg.2020.611517] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Accepted: 12/11/2020] [Indexed: 11/13/2022] Open
Abstract
Cochlear implants electrically stimulate surviving auditory neurons in the cochlea to provide severely or profoundly deaf people with access to hearing. Signal processing strategies derive frequency-specific information from the acoustic signal and code amplitude changes in frequency bands onto amplitude changes of current pulses emitted by the tonotopically arranged intracochlear electrodes. This article first describes how parameters of the electrical stimulation influence the loudness evoked and then summarizes two different phenomenological models developed by McKay and colleagues that have been used to explain psychophysical effects of stimulus parameters on loudness, detection, and modulation detection. The Temporal Model is applied to single-electrode stimuli and integrates cochlear neural excitation using a central temporal integration window analogous to that used in models of normal hearing. Perceptual decisions are made using decision criteria applied to the output of the integrator. By fitting the model parameters to a variety of psychophysical data, inferences can be made about how electrical stimulus parameters influence neural excitation in the cochlea. The Detailed Model is applied to multi-electrode stimuli, and includes effects of electrode interaction at a cochlear level and a transform between integrated excitation and specific loudness. The Practical Method of loudness estimation is a simplification of the Detailed Model and can be used to estimate the relative loudness of any multi-electrode pulsatile stimuli without the need to model excitation at the cochlear level. Clinical applications of these models to novel sound processing strategies are described.
Collapse
Affiliation(s)
- Colette M. McKay
- Bionics Institute, Melbourne, VIC, Australia
- Department of Medical Bionics, University of Melbourne, Melbourne, VIC, Australia
| |
Collapse
|
7
|
Zhou N, Zhu Z, Dong L, Galvin JJ. Effect of pulse phase duration on forward masking and spread of excitation in cochlear implant listeners. PLoS One 2020; 15:e0236179. [PMID: 32687516 PMCID: PMC7371170 DOI: 10.1371/journal.pone.0236179] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Accepted: 06/30/2020] [Indexed: 11/18/2022] Open
Abstract
Previous cochlear implant (CI) research has shown that at a pulse train with a long pulse phase duration (PPD) requires less current but greater charge to obtain the same loudness as a pulse train with a short PPD. This might result in different excitation patterns between long and short PPDs. At equal loudness, long PPDs might produce greater masking due to greater charge. However, because they require less current, long PPDs may produce a smaller spatial spread of excitation (SOE) compared to short PPDs by evoking a greater neural firing probability within the relatively small current field. To investigate the effects of PPD on excitation patterns, overall masking and SOE were compared for equally loud stimuli with short or long PPD in 10 adult CI ears. Forward masking patterns were measured at relatively soft, medium, and loud presentation levels. Threshold shifts were calculated in terms of percent dynamic range (DR) of the probe. The area under the curve (AUC) of the masking functions was significantly larger for the long PPD than for the short PPD masker. The difference in AUC was proportional to the difference in charge between the short and long PPD maskers. To estimate SOE, the masking patterns were first normalized to the peak masking, and then AUC was calculated. SOE was significantly larger for the short PPD than for the long PPD masker. Thus, at equal loudness, long PPDs produced greater overall masking (possibly due to greater charge) but less SOE (possibly due to less current spread) than did short PPDs. The effect of the interaction between masking and SOE by long PPD stimulation remains to be tested.
Collapse
Affiliation(s)
- Ning Zhou
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, North Carolina, United States of America
| | - Zhen Zhu
- Department of Engineering, East Carolina University, Greenville, North Carolina, United States of America
| | - Lixue Dong
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, North Carolina, United States of America
| | - John J. Galvin
- House Ear Institute, Los Angeles, California, United States of America
- * E-mail:
| |
Collapse
|
8
|
Kleinlogel S, Vogl C, Jeschke M, Neef J, Moser T. Emerging approaches for restoration of hearing and vision. Physiol Rev 2020; 100:1467-1525. [DOI: 10.1152/physrev.00035.2019] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Impairments of vision and hearing are highly prevalent conditions limiting the quality of life and presenting a major socioeconomic burden. For long, retinal and cochlear disorders have remained intractable for causal therapies, with sensory rehabilitation limited to glasses, hearing aids, and electrical cochlear or retinal implants. Recently, the application of gene therapy and optogenetics to eye and ear has generated hope for a fundamental improvement of vision and hearing restoration. To date, one gene therapy for the restoration of vision has been approved and undergoing clinical trials will broaden its application including gene replacement, genome editing, and regenerative approaches. Moreover, optogenetics, i.e. controlling the activity of cells by light, offers a more general alternative strategy. Over little more than a decade, optogenetic approaches have been developed and applied to better understand the function of biological systems, while protein engineers have identified and designed new opsin variants with desired physiological features. Considering potential clinical applications of optogenetics, the spotlight is on the sensory systems. Multiple efforts have been undertaken to restore lost or hampered function in eye and ear. Optogenetic stimulation promises to overcome fundamental shortcomings of electrical stimulation, namely poor spatial resolution and cellular specificity, and accordingly to deliver more detailed sensory information. This review aims at providing a comprehensive reference on current gene therapeutic and optogenetic research relevant to the restoration of hearing and vision. We will introduce gene-therapeutic approaches and discuss the biotechnological and optoelectronic aspects of optogenetic hearing and vision restoration.
Collapse
Affiliation(s)
| | | | | | | | - Tobias Moser
- Institute for Auditory Neuroscience, University Medical Center Goettingen, Germany
| |
Collapse
|
9
|
Forward masking patterns by low and high-rate stimulation in cochlear implant users: Differences in masking effectiveness and spread of neural excitation. Hear Res 2020; 389:107921. [PMID: 32097828 DOI: 10.1016/j.heares.2020.107921] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2019] [Revised: 01/15/2020] [Accepted: 02/13/2020] [Indexed: 11/20/2022]
Abstract
The goal of the present study was to compare forward masking patterns by stimulation of low and high rates in cochlear implant users. Postlingually deafened Cochlear Nucleus® device users participated in the study. In experiment 1, two maskers of different rates (250 and 1000 pulses per second) were set at levels that produced equal masking for a probe presented at the same electrode as the maskers. This aligned the two masking functions at the on-site probe location. Then their forward masking patterns for the far probes were compared. Results showed that slope of the masked probe-threshold decay as a function of probe-masker separation was steeper for the high-rate than the low-rate masker. A linear model indicated that this difference in spread of neural excitation (SOE) was accounted for by two factors that were not correlated with each other. One factor was that the low-rate masker required a considerably higher current level to be equally effective in masking as the high-rate masker. The second factor was the effect of stimulation rate on loudness, i.e., integration of multiple pulses. This was consistent with our hypothesis that if an increase in stimulation rate does not result in an increased total neural response, then it is unlikely that the change in rate would change spatial distribution of the neural activity. Interestingly, the difference in masking effectiveness of the maskers predicted subjects' speech recognition. Poorer performers were those who showed more comparable masking effects by maskers of different rates. The difference in the masking effectiveness may indirectly measure the auditory neurons' excitability, which predicts speech recognition. In experiment 2, SOE of the high-rate and low-rate maskers were compared at a level that is clinically relevant, i.e., equal loudness. At equal loudness, high-rate stimulation not only produced an overall greater amount of forward masking, but also a shallower decay of masking with probe-masker separation (wider SOE), compared to low rate. The difference in SOE was the opposite to the findings from experiment 1. Whether the maskers were calibrated for equal masking or loudness, the absolute current level was always higher for the low-rate masker, which suggests that the SOE patterns cannot be explained by current spread alone. The fact that high-rate stimulation produced greater masking and wider SOE at equal loudness may explain why using high stimulation rates has not produced consistent benefits for speech recognition, and why lowering stimulation rate from the manufacturer's default sometimes results in improved speech recognition for subjects.
Collapse
|
10
|
Reducing Simulated Channel Interaction Reveals Differences in Phoneme Identification Between Children and Adults With Normal Hearing. Ear Hear 2019; 40:295-311. [PMID: 29927780 DOI: 10.1097/aud.0000000000000615] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Channel interaction, the stimulation of overlapping populations of auditory neurons by distinct cochlear implant (CI) channels, likely limits the speech perception performance of CI users. This study examined the role of vocoder-simulated channel interaction in the ability of children with normal hearing (cNH) and adults with normal hearing (aNH) to recognize spectrally degraded speech. The primary aim was to determine the interaction between number of processing channels and degree of simulated channel interaction on phoneme identification performance as a function of age for cNH and to relate those findings to aNH and to CI users. DESIGN Medial vowel and consonant identification of cNH (age 8-17 years) and young aNH were assessed under six (for children) or nine (for adults) different conditions of spectral degradation. Stimuli were processed using a noise-band vocoder with 8, 12, and 15 channels and synthesis filter slopes of 15 (aNH only), 30, and 60 dB/octave (all NH subjects). Steeper filter slopes (larger numbers) simulated less electrical current spread and, therefore, less channel interaction. Spectrally degraded performance of the NH listeners was also compared with the unprocessed phoneme identification of school-aged children and adults with CIs. RESULTS Spectrally degraded phoneme identification improved as a function of age for cNH. For vowel recognition, cNH exhibited an interaction between the number of processing channels and vocoder filter slope, whereas aNH did not. Specifically, for cNH, increasing the number of processing channels only improved vowel identification in the steepest filter slope condition. Additionally, cNH were more sensitive to changes in filter slope. As the filter slopes increased, cNH continued to receive vowel identification benefit beyond where aNH performance plateaued or reached ceiling. For all NH participants, consonant identification improved with increasing filter slopes but was unaffected by the number of processing channels. Although cNH made more phoneme identification errors overall, their phoneme error patterns were similar to aNH. Furthermore, consonant identification of adults with CI was comparable to aNH listening to simulations with shallow filter slopes (15 dB/octave). Vowel identification of earlier-implanted pediatric ears was better than that of later-implanted ears and more comparable to cNH listening in conditions with steep filter slopes (60 dB/octave). CONCLUSIONS Recognition of spectrally degraded phonemes improved when simulated channel interaction was reduced, particularly for children. cNH showed an interaction between number of processing channels and filter slope for vowel identification. The differences observed between cNH and aNH suggest that identification of spectrally degraded phonemes continues to improve through adolescence and that children may benefit from reduced channel interaction beyond where adult performance has plateaued. Comparison to CI users suggests that early implantation may facilitate development of better phoneme discrimination.
Collapse
|
11
|
Abstract
Supplemental Digital Content is available in the text. Objectives: The standard, monopolar (MP) electrode configuration used in commercially available cochlear implants (CI) creates a broad electrical field, which can lead to unwanted channel interactions. Use of more focused configurations, such as tripolar and phased array, has led to mixed results for improving speech understanding. The purpose of the present study was to assess the efficacy of a physiologically inspired configuration called dynamic focusing, using focused tripolar stimulation at low levels and less focused stimulation at high levels. Dynamic focusing may better mimic cochlear excitation patterns in normal acoustic hearing, while reducing the current levels necessary to achieve sufficient loudness at high levels. Design: Twenty postlingually deafened adult CI users participated in the study. Speech perception was assessed in quiet and in a four-talker babble background noise. Speech stimuli were closed-set spondees in noise, and medial vowels at 50 and 60 dB SPL in quiet and in noise. The signal to noise ratio was adjusted individually such that performance was between 40 and 60% correct with the MP strategy. Subjects were fitted with three experimental strategies matched for pulse duration, pulse rate, filter settings, and loudness on a channel-by-channel basis. The strategies included 14 channels programmed in MP, fixed partial tripolar (σ = 0.8), and dynamic partial tripolar (σ at 0.8 at threshold and 0.5 at the most comfortable level). Fifteen minutes of listening experience was provided with each strategy before testing. Sound quality ratings were also obtained. Results: Speech perception performance for vowel identification in quiet at 50 and 60 dB SPL and for spondees in noise was similar for the three tested strategies. However, performance on vowel identification in noise was significantly better for listeners using the dynamic focusing strategy. Sound quality ratings were similar for the three strategies. Some subjects obtained more benefit than others, with some individual differences explained by the relation between loudness growth and the rate of change from focused to broader stimulation. Conclusions: These initial results suggest that further exploration of dynamic focusing is warranted. Specifically, optimizing such strategies on an individual basis may lead to improvements in speech perception for more adult listeners and improve how CIs are tailored. Some listeners may also need a longer period of time to acclimate to a new program.
Collapse
|
12
|
Carlyon RP, Deeks JM, Undurraga J, Macherey O, van Wieringen A. Spatial Selectivity in Cochlear Implants: Effects of Asymmetric Waveforms and Development of a Single-Point Measure. J Assoc Res Otolaryngol 2017; 18:711-727. [PMID: 28755309 PMCID: PMC5612920 DOI: 10.1007/s10162-017-0625-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2016] [Accepted: 05/05/2017] [Indexed: 01/07/2023] Open
Abstract
Three experiments studied the extent to which cochlear implant users' spatial selectivity can be manipulated using asymmetric waveforms and tested an efficient method for comparing spatial selectivity produced by different stimuli. Experiment 1 measured forward-masked psychophysical tuning curves (PTCs) for a partial tripolar (pTP) probe. Maskers were presented on bipolar pairs separated by one unused electrode; waveforms were either symmetric biphasic ("SYM") or pseudomonophasic with the short high-amplitude phase being either anodic ("PSA") or cathodic ("PSC") on the more apical electrode. For the SYM masker, several subjects showed PTCs consistent with a bimodal excitation pattern, with discrete excitation peaks on each electrode of the bipolar masker pair. Most subjects showed significant differences between the PSA and PSC maskers consistent with greater masking by the electrode where the high-amplitude phase was anodic, but the pattern differed markedly across subjects. Experiment 2 measured masked excitation patterns for a pTP probe and either a monopolar symmetric biphasic masker ("MP_SYM") or pTP pseudomonophasic maskers where the short high-amplitude phase was either anodic ("TP_PSA") or cathodic ("TP_PSC") on the masker's central electrode. Four of the five subjects showed significant differences between the masker types, but again the pattern varied markedly across subjects. Because the levels of the maskers were chosen to produce the same masking of a probe on the same channel as the masker, it was correctly predicted that maskers that produce broader masking patterns would sound louder. Experiment 3 exploited this finding by using a single-point measure of spread of excitation to reveal significantly better spatial selectivity for TP_PSA compared to TP_PSC maskers.
Collapse
Affiliation(s)
- Robert P Carlyon
- MRC Cognition and Brain Sciences Unit, 15 Chaucer Rd, Cambridge, CB1 3DA, UK
| | - John M Deeks
- MRC Cognition and Brain Sciences Unit, 15 Chaucer Rd, Cambridge, CB1 3DA, UK.
| | - Jaime Undurraga
- ExpORL, Department of Neurosciences, KULeuven, Herestraat 49 bus 721, 3000, Leuven, Belgium
| | - Olivier Macherey
- MRC Cognition and Brain Sciences Unit, 15 Chaucer Rd, Cambridge, CB1 3DA, UK
- LMA-CNRS, UPR 7051, Aix-Marseille University, Centrale Marseille, 4, Impasse Nikola Tesla, CS40006, 13453, Marseille Cedex 13, France
| | - Astrid van Wieringen
- ExpORL, Department of Neurosciences, KULeuven, Herestraat 49 bus 721, 3000, Leuven, Belgium
| |
Collapse
|
13
|
Comparison of Multipole Stimulus Configurations With Respect to Loudness and Spread of Excitation. Ear Hear 2017; 38:487-496. [DOI: 10.1097/aud.0000000000000416] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
14
|
Padilla M, Stupak N, Landsberger DM. Pitch ranking with different virtual channel configurations in electrical hearing. Hear Res 2017; 348:54-62. [DOI: 10.1016/j.heares.2017.02.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/15/2016] [Revised: 02/09/2017] [Accepted: 02/14/2017] [Indexed: 11/29/2022]
|
15
|
Nogueira W, Litvak LM, Landsberger DM, Büchner A. Loudness and pitch perception using Dynamically Compensated Virtual Channels. Hear Res 2016; 344:223-234. [PMID: 27939418 DOI: 10.1016/j.heares.2016.11.017] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/10/2016] [Revised: 11/26/2016] [Accepted: 11/29/2016] [Indexed: 10/20/2022]
Abstract
Reducing power consumption is important for the development of smaller cochlear implant (CI) speech processors. Simultaneous electrode stimulation may improve power efficiency by minimizing the required current applied to a given electrode. Simultaneous in-phase stimulation on adjacent electrodes (i.e. virtual channels) can be used to elicit pitch percepts intermediate to the ones provided by each of the physical electrodes in isolation. Virtual channels are typically implemented in monopolar stimulation mode, producing broad excitation patterns. Focused stimulation may reduce the excitation patterns, but is inefficient in terms of power consumption. To create a more power efficient virtual channel, we developed the Dynamically Compensated Virtual Channel (DC-VC) using four adjacent electrodes. The two central electrodes are current steered using the coefficient α (0<α<1 ) whereas the two flanking electrodes are used to focus/unfocus the stimulation with the coefficient σ (-1<σ<1). With increasing values of σ, power can be saved at the potential expense of generating broader electric fields. Additionally, reshaping the electric fields might also alter place pitch coding. The goal of the present study is to investigate the tradeoff between place pitch encoding and power savings using simultaneous electrode stimulation in the DC-VC configuration. A computational model and psychophysical experiments in CI users have been used for that purpose. Results from 10 adult Advanced Bionics CI users have been collected. Results show that the required current to produce comfortable levels is significantly reduced with increasing σ as predicted by the computational model. Moreover, no significant differences in the estimated number of discriminable steps were detected for the different values of σ. From these results, we conclude that DC-VCs can reduce power consumption without decreasing the number of discriminable place pitch steps.
Collapse
Affiliation(s)
- Waldo Nogueira
- Medical University Hannover, Cluster of Excellence "Hearing4all", Hannover, Germany.
| | | | | | - Andreas Büchner
- Medical University Hannover, Cluster of Excellence "Hearing4all", Hannover, Germany
| |
Collapse
|
16
|
Marozeau J, McKay CM. Perceptual Spaces Induced by Cochlear Implant All-Polar Stimulation Mode. Trends Hear 2016; 20:20/0/2331216516659251. [PMID: 27604784 PMCID: PMC5017566 DOI: 10.1177/2331216516659251] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
It has been argued that a main limitation of the cochlear implant is the spread of current induced by each electrode, which activates an inappropriately large range of sensory neurons. To reduce this spread, an alternative stimulation mode, the all-polar mode, was tested with five participants. It was designed to activate all the electrodes simultaneously with appropriate current levels and polarities to recruit narrower regions of auditory nerves at specific intracochlear electrode positions (denoted all-polar electrodes). In this study, the all-polar mode was compared with the current commercial stimulation mode: the monopolar mode. The participants were asked to judge the sound dissimilarity between pairs of two-electrode pulse-train stimuli that differed in the electrode positions and were presented in either monopolar or all-polar mode with pulses on the two electrodes presented either sequentially or simultaneously. The dissimilarity ratings were analyzed using a multidimensional scaling technique and three-dimensional stimulus perceptual spaces were produced. For all the conditions (mode and simultaneity), the first perceptual dimension was highly correlated with the position of the most apical activated electrode of the electrical stimulation and the second dimension with the position of the most basal electrode. In both sequential and simultaneous conditions, the monopolar and all-polar stimuli were significantly separated by a third dimension, which may indicate that all-polar stimuli have a perceptual quality that differs from monopolar stimuli. Overall, the results suggest that both modes might successfully represent spectral information in a sound processing strategy.
Collapse
Affiliation(s)
- Jeremy Marozeau
- Technical University of Denmark, Lyngby, Denmark Bionics Institute, East Melbourne, Australia
| | - Colette M McKay
- Department of Medical Bionics, University of Melbourne, Australia Bionics Institute, East Melbourne, Australia
| |
Collapse
|
17
|
Landsberger DM, Svrakic M, Roland JT, Svirsky M. The Relationship Between Insertion Angles, Default Frequency Allocations, and Spiral Ganglion Place Pitch in Cochlear Implants. Ear Hear 2016; 36:e207-13. [PMID: 25860624 DOI: 10.1097/aud.0000000000000163] [Citation(s) in RCA: 172] [Impact Index Per Article: 21.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES Commercially available cochlear implant systems attempt to deliver frequency information going down to a few hundred Hertz, but the electrode arrays are not designed to reach the most apical regions of the cochlea, which correspond to these low frequencies. This may cause a mismatch between the frequencies presented by a cochlear implant electrode array and the frequencies represented at the corresponding location in a normal-hearing cochlea. In the following study, the mismatch between the frequency presented at a given cochlear angle and the frequency expected by an acoustic hearing ear at the corresponding angle is examined for the cochlear implant systems that are most commonly used in the United States. DESIGN The angular insertion of each of the electrodes on four different electrode arrays (MED-EL Standard, MED-EL Flex28, Advanced Bionics HiFocus 1J, and Cochlear Contour Advance) was estimated from X-ray. For the angular location of each electrode on each electrode array, the predicted spiral ganglion frequency was estimated. The predicted spiral ganglion frequency was compared with the center frequency provided by the corresponding electrode using the manufacturer's default frequency-to-electrode allocation. RESULTS Differences across devices were observed for the place of stimulation for frequencies below 650 Hz. Longer electrode arrays (i.e., the MED-EL Standard and Flex28) demonstrated smaller deviations from the spiral ganglion map than the other electrode arrays. For insertion angles up to approximately 270°, the frequencies presented at a given location were typically approximately an octave below what would be expected by a spiral ganglion frequency map, while the deviations were larger for angles deeper than 270°. For frequencies above 650 Hz, the frequency to angle relationship was consistent across all four electrode models. CONCLUSIONS A mismatch was observed between the predicted frequency and the default frequency provided by every electrode on all electrode arrays. The mismatch can be reduced by changing the default frequency allocations, inserting electrodes deeper into the cochlea, or allowing cochlear implant users to adapt to the mismatch. Further studies are required to fully assess the clinical significance of the frequency mismatch.
Collapse
Affiliation(s)
- David M Landsberger
- Department of Otolaryngology, New York University School of Medicine, New York, USA
| | | | | | | |
Collapse
|
18
|
Guevara N, Hoen M, Truy E, Gallego S. A Cochlear Implant Performance Prognostic Test Based on Electrical Field Interactions Evaluated by eABR (Electrical Auditory Brainstem Responses). PLoS One 2016; 11:e0155008. [PMID: 27149268 PMCID: PMC4858145 DOI: 10.1371/journal.pone.0155008] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2015] [Accepted: 04/22/2016] [Indexed: 11/18/2022] Open
Abstract
Background Cochlear implants (CIs) are neural prostheses that have been used routinely in the clinic over the past 25 years. They allow children who were born profoundly deaf, as well as adults affected by hearing loss for whom conventional hearing aids are insufficient, to attain a functional level of hearing. The “modern” CI (i.e., a multi-electrode implant using sequential coding strategies) has yielded good speech comprehension outcomes (recognition level for monosyllabic words about 50% to 60%, and sentence comprehension close to 90%). These good average results however hide a very important interindividual variability as scores in a given patients’ population often vary from 5 to 95% in comparable testing conditions. Our aim was to develop a prognostic model for patients with unilateral CI. A novel method of objectively measuring electrical and neuronal interactions using electrical auditory brainstem responses (eABRs) is proposed. Methods and Findings The method consists of two measurements: 1) eABR measurements with stimulation by a single electrode at 70% of the dynamic range (four electrodes distributed within the cochlea were tested), followed by a summation of these four eABRs; 2) Measurement of a single eABR with stimulation from all four electrodes at 70% of the dynamic range. A comparison of the eABRs obtained by these two measurements, defined as the monaural interaction component (MIC), indicated electrical and neural interactions between the stimulation channels. Speech recognition performance without lip reading was measured for each patient using a logatome test (64 "vowel-consonant-vowel"; VCV; by forced choice of 1 out of 16). eABRs were measured in 16 CI patients (CIs with 20 electrodes, Digisonic SP; Oticon Medical ®, Vallauris, France). Significant correlations were found between speech recognition performance and the ratio of the amplitude of the V wave of the eABRs obtained with the two measurements (Pearson's linear regression model, parametric correlation: r2 = 0.26, p<0.05). Conclusions This prognostic model allowed a substantial amount of the interindividual variance in speech recognition scores to be explained. The present study used measurements of electrical and neuronal interactions by eABR to assess patients' bio-electric capacity to use multiple information channels supplied by the implant. This type of prognostic information may be valuable in several ways. On the patient level, it allows customizing of individual treatments. ClinicalTrials.gov Identifier: NCT01805167
Collapse
Affiliation(s)
- Nicolas Guevara
- University Head and Neck Institute, CHU de Nice, 31 Avenue de Valombrose, 06107 Nice cedex 2, France
| | - Michel Hoen
- Oticon Medical, Clinical and Scientific Research Department, 2720 chemin St Bernard, 06220 Vallauris, France
| | - Eric Truy
- Department of Audiology and Otorhinolaryngology, Edouard Herriot Hospital, 5 Place d'Arsonval, 69437 Lyon, France
| | - Stéphane Gallego
- Institute for Readaptation Sciences and Techniques, 8 Avenue Rockefeller, 69373 Lyon Cedex 08, France
| |
Collapse
|
19
|
Stahl P, Macherey O, Meunier S, Roman S. Rate discrimination at low pulse rates in normal-hearing and cochlear implant listeners: Influence of intracochlear stimulation site. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2016; 139:1578. [PMID: 27106306 DOI: 10.1121/1.4944564] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Temporal pitch perception in cochlear implantees remains weaker than in normal hearing listeners and is usually limited to rates below about 300 pulses per second (pps). Recent studies have suggested that stimulating the apical part of the cochlea may improve the temporal coding of pitch by cochlear implants (CIs), compared to stimulating other sites. The present study focuses on rate discrimination at low pulse rates (ranging from 20 to 104 pps). Two experiments measured and compared pulse rate difference limens (DLs) at four fundamental frequencies (ranging from 20 to 104 Hz) in both CI and normal-hearing (NH) listeners. Experiment 1 measured DLs in users of the (Med-El CI, Innsbruck, Austria) device for two electrodes (one apical and one basal). In experiment 2, DLs for NH listeners were compared for unresolved harmonic complex tones filtered in two frequency regions (lower cut-off frequencies of 1200 and 3600 Hz, respectively) and for different bandwidths. Pulse rate discrimination performance was significantly better when stimulation was provided by the apical electrode in CI users and by the lower-frequency tone complexes in NH listeners. This set of data appears consistent with better temporal coding when stimulation originates from apical regions of the cochlea.
Collapse
Affiliation(s)
- Pierre Stahl
- Laboratoire de Mécanique et d'acoustique-CNRS, Unité Propre de Recherche 7051, Aix-Marseille University, Centrale Marseille, 4 Impasse Nikola Tesla, CS-40006 Marseille Cedex 13, France
| | - Olivier Macherey
- Laboratoire de Mécanique et d'acoustique-CNRS, Unité Propre de Recherche 7051, Aix-Marseille University, Centrale Marseille, 4 Impasse Nikola Tesla, CS-40006 Marseille Cedex 13, France
| | - Sabine Meunier
- Laboratoire de Mécanique et d'acoustique-CNRS, Unité Propre de Recherche 7051, Aix-Marseille University, Centrale Marseille, 4 Impasse Nikola Tesla, CS-40006 Marseille Cedex 13, France
| | - Stéphane Roman
- Department of Pediatric Otolaryngology and Neck Surgery, Aix-Marseille University, Marseille, France
| |
Collapse
|
20
|
Padilla M, Landsberger DM. Reduction in spread of excitation from current focusing at multiple cochlear locations in cochlear implant users. Hear Res 2016; 333:98-107. [PMID: 26778546 DOI: 10.1016/j.heares.2016.01.002] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2015] [Revised: 12/23/2015] [Accepted: 01/02/2016] [Indexed: 10/22/2022]
Abstract
Channel interaction from a broad spread of excitation is likely to be a limiting factor in performance by cochlear implant users. Although partial tripolar stimulation has been shown to reduce spread of excitation, the magnitude of the reduction is highly variable across subjects. Because the reduction in spread of excitation is typically only measured at one electrode for a given subject, the degree of variability across cochlear locations is unknown. The first goal of the present study was to determine if the reduction in spread of excitation observed from partial tripolar current focusing systematically varies across the cochlea. The second goal was to measure the variability in reduction of spread of excitation relative to monopolar stimulation across the cochlea. The third goal was to expand upon previous results that suggest that scaling of verbal descriptors can be used to predict the reduction in spread of excitation, by increasing the limited number of sites previously evaluated and verify the relationships remain with the larger dataset. The spread of excitation for monopolar and partial tripolar stimulation was measured at 5 cochlear locations using a psychophysical forward masking task. Results of the present study suggest that although partial tripolar stimulation typically reduces spread of excitation, the degree of reduction in spread of excitation was found to be highly variable and no effect of cochlear location was found. Additionally, subjective scaling of certain verbal descriptors (Clean/Dirty, Pure/Noisy) correlated with the reduction in spread of excitation suggesting sound quality scaling might be used as a quick clinical estimate of channels providing a reduction in spread of excitation. This quick scaling technique might help clinicians determine which patients would be most likely to benefit from a focused strategy.
Collapse
Affiliation(s)
- Monica Padilla
- House Research Institute, Department of Communication and Neuroscience, 2100 West 3rd Street, Los Angeles, CA 90057, USA; Department of Otolaryngology, New York University School of Medicine, 550 1st Avenue STE NBV 5E5, New York, NY 10016, USA; Department of Otolaryngology, Keck School of Medicine, University of Southern California, 806 W. Adams Blvd., Los Angeles, CA 90007, USA.
| | - David M Landsberger
- House Research Institute, Department of Communication and Neuroscience, 2100 West 3rd Street, Los Angeles, CA 90057, USA; Department of Otolaryngology, New York University School of Medicine, 550 1st Avenue STE NBV 5E5, New York, NY 10016, USA
| |
Collapse
|
21
|
Fielden CA, Kluk K, Boyle PJ, McKay CM. The perception of complex pitch in cochlear implants: A comparison of monopolar and tripolar stimulation. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2015; 138:2524-36. [PMID: 26520335 DOI: 10.1121/1.4931910] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Cochlear implant listeners typically perform poorly in tasks of complex pitch perception (e.g., musical pitch and voice pitch). One explanation is that wide current spread during implant activation creates channel interactions that may interfere with perception of temporal fundamental frequency information contained in the amplitude modulations within channels. Current focusing using a tripolar mode of stimulation has been proposed as a way of reducing channel interactions, minimising spread of excitation and potentially improving place and temporal pitch cues. The present study evaluated the effect of mode in a group of cochlear implant listeners on a pitch ranking task using male and female singing voices separated by either a half or a quarter octave. Results were variable across participants, but on average, pitch ranking was at chance level when the pitches were a quarter octave apart and improved when the difference was a half octave. No advantage was observed for tripolar over monopolar mode at either pitch interval, suggesting that previously published psychophysical advantages for focused modes may not translate into improvements in complex pitch ranking. Evaluation of the spectral centroid of the stimulation pattern, plus a lack of significant difference between male and female voices, suggested that participants may have had difficulty in accessing temporal pitch cues in either mode.
Collapse
Affiliation(s)
- Claire A Fielden
- School of Psychological Sciences, University of Manchester, Ellen Wilkinson Building, Oxford Road, Manchester M13 9PL, United Kingdom
| | - Karolina Kluk
- School of Psychological Sciences, University of Manchester, Ellen Wilkinson Building, Oxford Road, Manchester M13 9PL, United Kingdom
| | - Patrick J Boyle
- Advanced Bionics UK Ltd., 2 Breaks House, Mill Court, Great Shelford, Cambridge, CB22 5LD, United Kingdom
| | - Colette M McKay
- School of Psychological Sciences, University of Manchester, Ellen Wilkinson Building, Oxford Road, Manchester M13 9PL, United Kingdom
| |
Collapse
|
22
|
Cosentino S, Deeks JM, Carlyon RP. Procedural Factors That Affect Psychophysical Measures of Spatial Selectivity in Cochlear Implant Users. Trends Hear 2015; 19:19/0/2331216515607067. [PMID: 26420785 PMCID: PMC4593626 DOI: 10.1177/2331216515607067] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Behavioral measures of spatial selectivity in cochlear implants are important both for guiding the programing of individual users’ implants and for the evaluation of different stimulation methods. However, the methods used are subject to a number of confounding factors that can contaminate estimates of spatial selectivity. These factors include off-site listening, charge interactions between masker and probe pulses in interleaved masking paradigms, and confusion effects in forward masking. We review the effects of these confounds and discuss methods for minimizing them. We describe one such method in which the level of a 125-pps masker is adjusted so as to mask a 125-pps probe, and where the masker and probe pulses are temporally interleaved. Five experiments describe the method and evaluate the potential roles of the different potential confounding factors. No evidence was obtained for off-site listening of the type observed in acoustic hearing. The choice of the masking paradigm was shown to alter the measured spatial selectivity. For short gaps between masker and probe pulses, both facilitation and refractory mechanisms had an effect on masking; this finding should inform the choice of stimulation rate in interleaved masking experiments. No evidence for confusion effects in forward masking was revealed. It is concluded that the proposed method avoids many potential confounds but that the choice of method should depend on the research question under investigation.
Collapse
Affiliation(s)
| | - John M Deeks
- MRC Cognition and Brain Sciences Unit, Cambridge, UK
| | | |
Collapse
|
23
|
George SS, Wise AK, Fallon JB, Shepherd RK. Evaluation of focused multipolar stimulation for cochlear implants in long-term deafened cats. J Neural Eng 2015; 12:036003. [PMID: 25834113 DOI: 10.1088/1741-2560/12/3/036003] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
OBJECTIVE Focused multipolar (FMP) stimulation has been shown to produce restricted neural activation using intracochlear stimulation in animals with a normal population of spiral ganglion neurons (SGNs). However, in a clinical setting, the widespread loss of SGNs and peripheral fibres following deafness is expected to influence the effectiveness of FMP. APPROACH We compared the efficacy of FMP stimulation to both monopolar (MP) and tripolar (TP) stimulation in long-term deafened cat cochleae (n = 8). Unlike our previous study, these cochleae contained <10% of the normal SGN population adjacent to the electrode array. We also evaluated the effect of electrode position on stimulation modes by using either modiolar facing or lateral wall facing half-band electrodes. The spread of neural activity across the inferior colliculus, a major nucleus within the central auditory pathway, was used as a measure of spatial selectivity. MAIN RESULTS In cochleae with significant SGN degeneration, we observed that FMP and TP stimulation resulted in greater spatial selectivity than MP stimulation (p < 0.001). However, thresholds were significantly higher for FMP and TP stimulation compared to MP stimulation (p < 0.001). No difference between FMP and TP stimulation was found in any measures. The high threshold levels for FMP stimulation was significantly reduced without compromising spatial selectivity by varying the degree of current focusing (referred as 'partial-FMP' stimulation). Spatial selectivity of all stimulation modes was unaffected by the electrode position. Finally, spatial selectivity in long-term deafened cochleae was significantly less than that of cochleae with normal SGN population (George S S et al 2014 J. Neural Eng. 11 065003). SIGNIFICANCE The present results indicate that the greater spatial selectivity of FMP and TP stimulation over MP stimulation is maintained in cochleae with significant neural degeneration and is not adversely affected by electrode position. The greater spatial selectivity of FMP and TP stimulation would be expected to result in improved clinical performance.
Collapse
Affiliation(s)
- Shefin S George
- The Bionics Institute, East Melbourne 3002, Australia. Department of Medical Bionics, University of Melbourne, Melbourne 3002, Australia
| | | | | | | |
Collapse
|
24
|
Perceptual interactions between electrodes using focused and monopolar cochlear stimulation. J Assoc Res Otolaryngol 2015; 16:401-12. [PMID: 25742726 DOI: 10.1007/s10162-015-0511-2] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2014] [Accepted: 02/13/2015] [Indexed: 01/06/2023] Open
Abstract
In today's cochlear implant (CI) systems, the monopolar (MP) electrode configuration is the most commonly used stimulation mode, requiring only a single current source. However, with an implant that will allow simultaneous activation of multiple independent current sources, it is possible to implement an all-polar (AP) stimulation mode designed to create a focused electrical field. The goal of this experiment was to study the potential benefits of this all-polar mode for reducing uncontrolled electrode interactions compared with the monopolar mode. The five participants who took part in the study were implanted with a research device that was connected via a percutaneous connector to a benchtop stimulator providing 22 independent current sources. The perceptual effects of the AP mode were tested in three experiments. In Experiment 1, the current level difference between loudness-matched sequential and simultaneous stimuli composed of 2 spatially separated pulse trains was measured as function of the electrode separation. Results indicated a strong current-summation interaction for simultaneous stimuli in the MP mode for separations up to at least 4.8 mm. No significant interaction was found in the AP mode beyond a separation of 2.4 mm. In Experiment 2, a forward-masking paradigm was used with fixed equally loud probes in AP and MP modes, and AP maskers presented on different electrode positions. Results indicated a similar spatial masking pattern between modes. In Experiment 3, subjects were asked to discriminate between across-electrode temporal delays. It was hypothesized that discrimination would decrease with electrode separation faster in AP compared to MP modes. However, results showed no difference between the two modes. Overall, the results indicated that the AP mode produced less current spread than MP mode but did not lead to a significant advantage in terms of spread of neuronal excitation at equally loud levels.
Collapse
|
25
|
Mesnildrey Q, Macherey O. Simulating the dual-peak excitation pattern produced by bipolar stimulation of a cochlear implant: effects on speech intelligibility. Hear Res 2014; 319:32-47. [PMID: 25449010 DOI: 10.1016/j.heares.2014.11.001] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2014] [Revised: 10/28/2014] [Accepted: 11/05/2014] [Indexed: 10/24/2022]
Abstract
Several electrophysiological and psychophysical studies have shown that the spatial excitation pattern produced by bipolar stimulation of a cochlear implant (CI) can have a dual-peak shape. The perceptual effects of this dual-peak shape were investigated using noise-vocoded CI simulations in which synthesis filters were designed to simulate the spread of neural activity produced by various electrode configurations, as predicted by a simple cochlear model. Experiments 1 and 2 tested speech recognition in the presence of a concurrent speech masker for various sets of single-peak and dual-peak synthesis filters and different numbers of channels. Similarly as results obtained in real CIs, both monopolar (MP, single-peak) and bipolar (BP + 1, dual-peak) simulations showed a plateau of performance above 8 channels. The benefit of increasing the number of channels was also lower for BP + 1 than for MP. This shows that channel interactions in BP + 1 become especially deleterious for speech intelligibility when a simulated electrode acts both as an active and as a return electrode for different channels because envelope information from two different analysis bands are being conveyed to the same spectral location. Experiment 3 shows that these channel interactions are even stronger in wide BP configuration (BP + 5), likely because the interfering speech envelopes are less correlated than in narrow BP + 1. Although the exact effects of dual- or multi-peak excitation in real CIs remain to be determined, this series of experiments suggest that multipolar stimulation strategies, such as bipolar or tripolar, should be controlled to avoid neural excitation in the vicinity of the return electrodes.
Collapse
Affiliation(s)
- Quentin Mesnildrey
- LMA-CNRS, UPR 7051, Aix-Marseille Univ., Centrale Marseille, 31 Chemin Joseph Aiguier, 13402 Marseille Cedex 20, France.
| | - Olivier Macherey
- LMA-CNRS, UPR 7051, Aix-Marseille Univ., Centrale Marseille, 31 Chemin Joseph Aiguier, 13402 Marseille Cedex 20, France
| |
Collapse
|
26
|
Bierer JA, Nye AD. Comparisons between detection threshold and loudness perception for individual cochlear implant channels. Ear Hear 2014; 35:641-51. [PMID: 25036146 PMCID: PMC4208951 DOI: 10.1097/aud.0000000000000058] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVE The objective of this study was to examine how the level of current required for cochlear implant listeners to detect single-channel electrical pulse trains relates to loudness perception on the same channel. The working hypothesis was that channels with relatively high thresholds, when measured with a focused current pattern, interface poorly to the auditory nerve. For such channels, a smaller dynamic range between perceptual threshold and the most comfortable loudness would result, in part, from a greater sensitivity to changes in electrical field spread compared to low-threshold channels. The narrower range of comfortable listening levels may have important implications for speech perception. DESIGN Data were collected from eight, adult cochlear implant listeners implanted with the HiRes90k cochlear implant (Advanced Bionics Corp.). The partial tripolar (pTP) electrode configuration, consisting of one intracochlear active electrode, two flanking electrodes carrying a fraction (σ) of the return current, and an extracochlear ground, was used for stimulation. Single-channel detection thresholds and most comfortable listening levels were acquired using the most focused pTP configuration possible (σ ≥ 0.8) to identify three channels for further testing-those with the highest, median, and lowest thresholds-for each subject. Threshold, equal-loudness contours (at 50% of the monopolar dynamic range), and loudness growth functions were measured for each of these three test channels using various pTP fractions. RESULTS For all test channels, thresholds increased as the electrode configuration became more focused. The rate of increase with the focusing parameter σ was greatest for the high-threshold channel compared to the median- and low-threshold channels. The 50% equal-loudness contours exhibited similar rates of increase in level across test channels and subjects. Additionally, test channels with the highest thresholds had the narrowest dynamic ranges (for σ ≥ 0.5) and steepest growth of loudness functions for all electrode configurations. CONCLUSIONS Together with previous studies using focused stimulation, the results suggest that auditory responses to electrical stimuli at both threshold and suprathreshold current levels are not uniform across the electrode array of individual cochlear implant listeners. Specifically, the steeper growth of loudness and thus smaller dynamic ranges observed for high-threshold channels are consistent with a degraded electrode-neuron interface, which could stem from lower numbers of functioning auditory neurons or a relatively large distance between the neurons and electrodes. These findings may have potential implications for how stimulation levels are set during the clinical mapping procedure, particularly for speech-processing strategies that use focused electrical fields.
Collapse
Affiliation(s)
- Julie Arenberg Bierer
- Department of Speech and Hearing Sciences, University of Washington, Seattle, WA, USA
| | | |
Collapse
|
27
|
Erfanian Saeedi N, Blamey PJ, Burkitt AN, Grayden DB. Application of a pitch perception model to investigate the effect of stimulation field spread on the pitch ranking abilities of cochlear implant recipients. Hear Res 2014; 316:129-37. [DOI: 10.1016/j.heares.2014.08.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2014] [Revised: 08/14/2014] [Accepted: 08/19/2014] [Indexed: 10/24/2022]
|
28
|
Fielden CA, Kluk K, McKay CM. Interpulse interval discrimination within and across channels: comparison of monopolar and tripolar mode of stimulation. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2014; 135:2913-2922. [PMID: 24815271 DOI: 10.1121/1.4869687] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Perception of temporal patterns is crucial to speech understanding and music perception in normal hearing, and is fundamental in the design and implementation of processing strategies for cochlear implants. Two experiments described here investigated the effect of stimulation mode (monopolar versus tripolar) on interpulse interval discrimination using single-electrode stimulation (experiment 1) and dual-electrode stimulation (experiment 2). Experiment 1 required participants to discriminate stimuli containing different interpulse intervals and experiment 2 required listeners to discriminate between two dual-electrode stimuli that had the same temporal pattern on each electrode, but differed in inter-electrode timing. The hypotheses were that (i) stimulation mode would affect the ability to distinguish interpulse interval patterns on a single electrode and (ii) the electrode separation range in which subjects were sensitive to inter-electrode timing would be more restricted in tripolar than in monopolar stimulation. Results in nine cochlear implant users showed that mode did not have a significant mean effect on either the ability to discriminate interpulse intervals in single-electrode stimulation or the range of electrode separation in dual-electrode stimulation in which participants were sensitive to inter-electrode timing. In conclusion, tripolar stimulation did not show any advantage in delivering temporal information within or across channels in this group.
Collapse
Affiliation(s)
- Claire A Fielden
- School of Psychological Sciences, Ellen Wilkinson Building, University of Manchester, Oxford Road, Manchester M13 9PL, United Kingdom
| | - Karolina Kluk
- School of Psychological Sciences, Ellen Wilkinson Building, University of Manchester, Oxford Road, Manchester M13 9PL, United Kingdom
| | - Colette M McKay
- School of Psychological Sciences, Ellen Wilkinson Building, University of Manchester, Oxford Road, Manchester M13 9PL, United Kingdom
| |
Collapse
|
29
|
Padilla M, Landsberger DM. Loudness summation using focused and unfocused electrical stimulation. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2014; 135:EL102-EL108. [PMID: 25234912 PMCID: PMC4042455 DOI: 10.1121/1.4862877] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2013] [Accepted: 12/11/2013] [Indexed: 06/03/2023]
Abstract
With a cochlear implant, when stimulation from multiple channels is interleaved, the perceived loudness is greater than the loudness associated with any of the individual channels presented in isolation. This phenomenon is known as loudness summation. This study examined if loudness summation with monopolar and tripolar stimulation were equivalent at two loudnesses and two spacing configurations. Results suggest that loudness summation is similar for monopolar and tripolar modes. However, larger summation differences were observed for softer sounds and louder sounds with a larger spatial separation. The results are consistent with the idea that loudness summation is dependent on channel interaction and have implications for implementing current-focused processing strategies.
Collapse
Affiliation(s)
- Monica Padilla
- House Research Institute, 2100 West 3rd Street, Los Angeles, California 90057 ,
| | - David M Landsberger
- House Research Institute, 2100 West 3rd Street, Los Angeles, California 90057 ,
| |
Collapse
|
30
|
Azadpour M, AlJasser A, McKay CM. Place specificity measured in forward and interleaved masking in cochlear implants. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2013; 134:EL314-EL320. [PMID: 24116536 DOI: 10.1121/1.4819182] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Interleaved masking in cochlear implants is analogous to acoustic simultaneous masking and is relevant to speech processing strategies that interleave pulses on concurrently activated electrodes. In this study, spatial decay of masking as the distance between masker and probe increases was compared between forward and interleaved masking in the same group of cochlear implant users. Spatial masking patterns and the measures of place specificity were similar between forward and interleaved masking. Unlike acoustic hearing where broader tuning curves are obtained in simultaneous masking, the type of masking experiment did not influence the measure of place specificity in cochlear implants.
Collapse
Affiliation(s)
- Mahan Azadpour
- Institute for Sensory Research, Syracuse University, 621 Skytop Road, Syracuse, New York 13244
| | | | | |
Collapse
|