1
|
Pérez-Contreras J, Loro-Ferrer JF, Merino-Muñoz P, Hermosilla-Palma F, Miranda-Lorca B, Bustamante-Garrido A, Inostroza-Ríos F, Brito CJ, Aedo-Muñoz E. Intra and Inter-Test Reliability of Isometric Hip Adduction Strength Test with Force Plates in Professional Soccer Players. J Funct Morphol Kinesiol 2024; 9:270. [PMID: 39728254 DOI: 10.3390/jfmk9040270] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2024] [Revised: 12/04/2024] [Accepted: 12/08/2024] [Indexed: 12/28/2024] Open
Abstract
Assessing the reliability of measurement instruments and equipment is essential to ensure the accurate tracking of athletes over extended periods, minimizing the measurement errors caused by chance or other factors. However, a less common but equally important analysis is the verification of inter-measurement agreement, which complements the reliability results. Purpose: To evaluate the intra- and inter-test reliability of an isometric hip adduction strength and asymmetries test in professional soccer players. Methods: Twenty-three professional male soccer players were evaluated on two occasions, 1 week apart. The force signal was collected using force plates (Pasco PS-2141), and the data processing was performed using Matlab software (R2023a, MathWorks, Natick, MA, USA). The peak force, interval RFD, peak RFD, peak force asymmetry and RFD were analyzed. Intraclass correlation coefficients (ICCs) and coefficients of variation (CV) were calculated to corroborate the intra- and inter-test reliability. In addition, the degree of agreement of the asymmetries was corroborated through the kappa index. Results: The peak force demonstrated an acceptable absolute reliability (CV < 10%) for the intra-test and test-retest condition, an excellent relative intra-test reliability and a good to moderate reliability for the test-retest reliability. However, the peak force asymmetry showed a moderate test-retest reliability and agreement. For the intra-test condition, the RFD variables demonstrate a moderate to excellent relative reliability; however, all demonstrate unacceptable absolute reliability (CV > 10%) in at least one of the evaluation sessions. A moderate to poor test-retest reliability and unacceptable absolute reliability were observed for all the RFD variables. Conclusions: The peak force is the variable with the highest intra- and inter-test reliability, so its use is recommended to longitudinally assess the maximum strength of the adductors in professional soccer players, but not the asymmetry orientation of the peak force. The RFD variables should be interpreted with caution due to their inconsistent reliability, and it is necessary to improve the methods used to achieve adequate reliability.
Collapse
Affiliation(s)
- Jorge Pérez-Contreras
- Escuela de Doctorado de La Universidad de Las Palmas de Gran Canaria (EDULPGC), 35016 Las Palmas, Spain
- Escuela de Ciencias del Deporte y Actividad Física, Facultad de Salud, Universidad Santo Tomas, Santiago 8370003, Chile
| | | | - Pablo Merino-Muñoz
- Núcleo de Investigación en Ciencias de la Motricidad Humana, Universidad Adventista de Chile, Chillán 3780000, Chile
- Biomedical Engineering Program, Federal University of Rio de Janeiro, Rio de Janeiro 21941-617, Brazil
| | - Felipe Hermosilla-Palma
- Escuela de Pedagogía en Educación Física, Facultad de Educación, Universidad Autónoma de Chile, Talca 3460000, Chile
| | - Brayan Miranda-Lorca
- Departamento de Educación Física, Deportes y Recreación, Facultad de Artes y Educación Física, Universidad Metropolitana de Ciencias de la Educación, Santiago 7760197, Chile
| | - Alejandro Bustamante-Garrido
- Escuela de Ciencias del Deporte y Actividad Física, Facultad de Salud, Universidad Santo Tomas, Santiago 8370003, Chile
- Departamento de Educación Física, Deportes y Recreación, Facultad de Artes y Educación Física, Universidad Metropolitana de Ciencias de la Educación, Santiago 7760197, Chile
| | - Felipe Inostroza-Ríos
- Department of Physical Education, Federal University of Juiz de Fora, Governador Valadares 35010-180, Brazil
| | - Ciro José Brito
- Department of Physical Education, Federal University of Juiz de Fora, Governador Valadares 35010-180, Brazil
| | - Esteban Aedo-Muñoz
- Escuela de Ciencias de la Actividad Física, El Deporte y la Salud, Facultad de Ciencias Médicas, Universidad de Santiago de Chile, Santiago 8370003, Chile
| |
Collapse
|
2
|
Brady CJ, Harrison AJ, Flanagan EP, Haff GG, Comyns TM. The Relationship Between the Isometric Squat and Stretch Shortening Cycle Function and Sprint Acceleration Performance in Hurling Players. J Strength Cond Res 2024; 38:e288-e298. [PMID: 38489584 DOI: 10.1519/jsc.0000000000004759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/17/2024]
Abstract
ABSTRACT Brady, CJ, Harrison, AJ, Flanagan, EP, Haff, GG, and Comyns, TM. The relationship between the isometric squat and stretch shortening cycle function and sprint acceleration performance in hurling players. J Strength Cond Res 38(6): e288-e298, 2024-The primary aim was to examine the relationship between sprint acceleration performance and the performance tests: isometric squat (ISqT), countermovement jump (CMJ), and reactive strength index (RSI). The secondary aim determined whether these tests could distinguish between sprint performance levels. Twenty-six male under-21 subjects completed the ISqT, with peak force (PF), relative PF, force at 100, 150, and 200 milliseconds (ms), and impulse (0-200 ms) measured. Jump height (JH) was calculated from the CMJ and RSI during the 10-5 repeated jump test. Subjects completed 3 × 30-m sprints with splits taken at 5, 10, 20, and 30 m. Pearson's product moment correlations were used to assess the relationships between measures, and independent samples t tests were used to determine whether differences existed in sprint ability of those in the top and bottom quartiles for force at 100 ms, CMJ, and RSI. Significant negative moderate correlations were reported between force at 100 ms and 0-5 m and 5-10 m, significant moderate and large negative correlations between CMJ and all splits and significant large correlations between RSI and splits over 5 m. Force at 100 ms distinguished between performance levels from 0 to 5 m, CMJ from 10 to 20 m, and RSI from 20 to 30 m; faster subjects produced significantly higher force, JHs, and RSI scores. Three principal components explaining 86.1% of the variation in the data set were identified: sprint times and stretch shortening cycle capabilities (33.3%), time-specific force (29.9%), and absolute and relative strength (22.8%).
Collapse
Affiliation(s)
- Claire J Brady
- Department of Physical Education and Sport Sciences, University of Limerick, Limerick, Ireland
- Sport Ireland Institute, IIS Building, National Sports Campus, Abbotstown, Ireland
| | - Andrew J Harrison
- Department of Physical Education and Sport Sciences, University of Limerick, Limerick, Ireland
- Health Research Unit, University of Limerick, Limerick, Ireland
| | - Eamonn P Flanagan
- Sport Ireland Institute, IIS Building, National Sports Campus, Abbotstown, Ireland
| | - Guy Gregory Haff
- School of Medical and Health Sciences, Edith Cowen University, Joondalup, Western Australia, Australia; and
- School of Health and Society, University of Salford, Salford, Greater, Manchester, United Kingdom
| | - Thomas M Comyns
- Department of Physical Education and Sport Sciences, University of Limerick, Limerick, Ireland
- Health Research Unit, University of Limerick, Limerick, Ireland
| |
Collapse
|
3
|
Warneke K, Wagner CM, Keiner M, Hillebrecht M, Schiemann S, Behm DG, Wallot S, Wirth K. Maximal strength measurement: A critical evaluation of common methods-a narrative review. Front Sports Act Living 2023; 5:1105201. [PMID: 36873661 PMCID: PMC9981657 DOI: 10.3389/fspor.2023.1105201] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Accepted: 01/30/2023] [Indexed: 02/19/2023] Open
Abstract
Measuring maximal strength (MSt) is a very common performance diagnoses, especially in elite and competitive sports. The most popular procedure in test batteries is to test the one repetition maximum (1RM). Since testing maximum dynamic strength is very time consuming, it often suggested to use isometric testing conditions instead. This suggestion is based on the assumption that the high Pearson correlation coefficients of r ≥ 0.7 between isometric and dynamic conditions indicate that both tests would provide similar measures of MSt. However, calculating r provides information about the relationship between two parameters, but does not provide any statement about the agreement or concordance of two testing procedures. Hence, to assess replaceability, the concordance correlation coefficient (ρ c) and the Bland-Altman analysis including the mean absolute error (MAE) and the mean absolute percentage error (MAPE) seem to be more appropriate. Therefore, an exemplary model based on r = 0.55 showed ρ c = 0.53, A MAE of 413.58 N and a MAPE = 23.6% with a range of -1,000-800 N within 95% Confidence interval (95%CI), while r = 0.7 and 0.92 showed ρ c = 0.68 with a MAE = 304.51N/MAPE = 17.4% with a range of -750 N-600 N within a 95% CI and ρ c = 0.9 with a MAE = 139.99/MAPE = 7.1% with a range of -200-450 N within a 95% CI, respectively. This model illustrates the limited validity of correlation coefficients to evaluate the replaceability of two testing procedures. Interpretation and classification of ρ c, MAE and MAPE seem to depend on expected changes of the measured parameter. A MAPE of about 17% between two testing procedures can be assumed to be intolerably high.
Collapse
Affiliation(s)
- Konstantin Warneke
- Department for Exercise, Sport and Health, Leuphana University Lüneburg, Lüneburg, Germany
- School of Human Kinetics and Recreation, Memorial University of Newfoundland, St. Johns, NL, Canada
| | - Carl-Maximilian Wagner
- Department of Training Science, German University of Health and Sport, Berlin, Baden-Württemberg, Germany
| | - Michael Keiner
- Department of Training Science, German University of Health and Sport, Berlin, Baden-Württemberg, Germany
| | - Martin Hillebrecht
- University Sports Center, Carl von Ossietzky University of Oldenburg, Oldenburg, Germany
| | - Stephan Schiemann
- Department for Exercise, Sport and Health, Leuphana University Lüneburg, Lüneburg, Germany
| | - David George Behm
- School of Human Kinetics and Recreation, Memorial University of Newfoundland, St. Johns, NL, Canada
| | | | - Klaus Wirth
- Faculty of Training and Sports Science, University of Applied Science Wiener Neustadt, Vienna, Austria
| |
Collapse
|
4
|
Determining concentric and eccentric force-velocity profiles during squatting. Eur J Appl Physiol 2022; 122:769-779. [PMID: 35038023 PMCID: PMC8854263 DOI: 10.1007/s00421-021-04875-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Accepted: 12/12/2021] [Indexed: 01/08/2023]
Abstract
Purpose The force–velocity relationship of muscular contraction has been extensively studied. However, previous research has focussed either on isolated muscle or single-joint movements, whereas human movement consists of multi-joint movements (e.g. squatting). Therefore, the purpose of this study was to investigate the force–velocity relationship of isovelocity squatting. Methods Fifteen male participants (24 ± 2 years, 79.8 ± 9.1 kg, 177.5 ± 6 cm) performed isovelocity squats on a novel motorised isovelocity device (Kineo Training System) at three concentric (0.25, 0.5, and 0.75 m s−1) and three eccentric velocities (− 0.25, − 0.5, and − 0.75 m s−1). Peak vertical ground reaction forces, that occurred during the isovelocity phase, were collected using dual force plates (2000 Hz) (Kistler, Switzerland). Results The group mean squat force–velocity profile conformed to the typical in vivo profile, with peak vertical ground reaction forces during eccentric squatting being 9.5 ± 19% greater than isometric (P = 0.037), and occurring between − 0.5 and − 0.75 m s−1. However, large inter-participant variability was identified (0.84–1.62 × isometric force), with some participants being unable to produce eccentric forces greater than isometric. Sub-group analyses could not identify differences between individuals who could/could not produce eccentric forces above isometric, although those who could not tended to be taller. Conclusions These finding suggest that variability exists between participants in the ability to generate maximum eccentric forces during squatting, and the magnitude of eccentric increase above isometric cannot be predicted solely based on a concentric assessment. Therefore, an assessment of eccentric capabilities may be required prior to prescribing eccentric-specific resistance training.
Collapse
|
5
|
Oranchuk DJ, Storey AG, Nelson AR, Neville JG, Cronin JB. Variability of Multiangle Isometric Force-Time Characteristics in Trained Men. J Strength Cond Res 2022; 36:284-288. [PMID: 31593034 DOI: 10.1519/jsc.0000000000003405] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
ABSTRACT Oranchuk, DJ, Storey, AG, Nelson, AR, Neville, JG, and Cronin, JB. Variability of multiangle isometric force-time characteristics in trained men. J Strength Cond Res 36(1): 284-288, 2022-Measurements of isometric force, rate of force development (RFD), and impulse are widely reported. However, little is known about the variability and reliability of these measurements at multiple angles, over repeated testing occasions in a homogenous, resistance-trained population. Thus, understanding the intersession variability of multiangle isometric force-time characteristics provides the purpose of this article. Three sessions of isometric knee extensions at 40°, 70°, and 100° of flexion were performed by 26 subjects across 51 limbs. All assessments were repeated on 3 occasions separated by 5-8 days. Variability was qualified by doubling the typical error of measurement (TEM), with thresholds of 0.2-0.6 (small), 0.6-1.2 (moderate), 1.2-2.0 (large), 2.0-4.0 (very large), and >4.0 (extremely large). In addition, variability was deemed large when the intraclass correlation coefficient (ICC) was <0.67 and coefficient of variation (CV) >10%; moderate when ICC >0.67 or CV <10% (but not both); and small when both ICC >0.67 and CV <10%. Small to moderate between-session variability (ICC = 0.68-0.95, CV = 5.2-18.7%, TEM = 0.24-0.49) was associated with isometric peak force, regardless of angle. Moderate to large variability was seen in early-stage (0-50 ms) RFD and impulse (ICC = 0.60-0.80, CV = 22.4-63.1%, TEM = 0.62-0.74). Impulse and RFD at 0-100 ms, 0-200 ms, and 100-200 ms were moderately variable (ICC = 0.71-0.89, CV = 11.8-42.1%, TEM = 0.38-0.60) at all joint angles. Isometric peak force and late-stage isometric RFD and impulse measurements were found to have low intersession variability regardless of joint angle. However, practitioners need to exercise caution when making inferences about early-stage RFD and impulse measures due to moderate-large variability.
Collapse
Affiliation(s)
- Dustin J Oranchuk
- Sports Performance Research Institute New Zealand, Auckland University of Technology, Auckland, New Zealand ; and
| | - Adam G Storey
- Sports Performance Research Institute New Zealand, Auckland University of Technology, Auckland, New Zealand ; and
| | - André R Nelson
- Institute for Health and Sport, Victoria University, Melbourne, Australia
| | - Jonathon G Neville
- Sports Performance Research Institute New Zealand, Auckland University of Technology, Auckland, New Zealand ; and
| | - John B Cronin
- Sports Performance Research Institute New Zealand, Auckland University of Technology, Auckland, New Zealand ; and
| |
Collapse
|
6
|
Lynch AE, Davies RW, Jakeman PM, Locke T, Allardyce JM, Carson BP. The Influence of Maximal Strength and Knee Angle on the Reliability of Peak Force in the Isometric Squat. Sports (Basel) 2021; 9:sports9100140. [PMID: 34678921 PMCID: PMC8539608 DOI: 10.3390/sports9100140] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 09/17/2021] [Accepted: 10/02/2021] [Indexed: 11/16/2022] Open
Abstract
This study aimed to investigate the test-retest reliability of peak force in the isometric squat across the strength spectrum using coefficient of variation (CV) and intra-class correlation coefficient (ICC). On two separate days, 59 healthy men (mean (SD) age 23.0 (4.1) years; height 1.79 (0.7) m; body mass 84.0 (15.2) kg) performed three maximal effort isometric squats in two positions (at a 120° and a 90° knee angle). Acceptable reliability was observed at both the 120° (CV = 7.5 (6.7), ICC = 0.960 [0.933, 0.977]) and 90° positions (CV = 9.2 (8.8), ICC = 0.920 [0.865, 0.953]). There was no relationship between peak force in the isometric squat and the test-retest reliability at either the 120° (r = 0.052, p = 0.327) or 90° (r = 0.014, p = 0.613) positions. A subgroup of subjects (n = 17) also completed the isometric squat test at a 65° knee angle. Acceptable reliability was observed in this position (CV = 9.6 (9.3), ICC = 0.916 [0.766, 0.970]) and reliability was comparable to the 120° and 90° positions. Therefore, we deem isometric squat peak force output to be a valid and reliable measure across the strength spectrum and in different isometric squat positions.
Collapse
Affiliation(s)
- Arthur E. Lynch
- Department of Physical Education and Sport Sciences, Faculty of Education and Health Sciences, University of Limerick, V94 T9PX Limerick, Ireland; (A.E.L.); (R.W.D.); (P.M.J.); (T.L.); (J.M.A.)
| | - Robert W. Davies
- Department of Physical Education and Sport Sciences, Faculty of Education and Health Sciences, University of Limerick, V94 T9PX Limerick, Ireland; (A.E.L.); (R.W.D.); (P.M.J.); (T.L.); (J.M.A.)
| | - Philip M. Jakeman
- Department of Physical Education and Sport Sciences, Faculty of Education and Health Sciences, University of Limerick, V94 T9PX Limerick, Ireland; (A.E.L.); (R.W.D.); (P.M.J.); (T.L.); (J.M.A.)
| | - Tim Locke
- Department of Physical Education and Sport Sciences, Faculty of Education and Health Sciences, University of Limerick, V94 T9PX Limerick, Ireland; (A.E.L.); (R.W.D.); (P.M.J.); (T.L.); (J.M.A.)
| | - Joanna M. Allardyce
- Department of Physical Education and Sport Sciences, Faculty of Education and Health Sciences, University of Limerick, V94 T9PX Limerick, Ireland; (A.E.L.); (R.W.D.); (P.M.J.); (T.L.); (J.M.A.)
- Health Research Institute, University of Limerick, V94 T9PX Limerick, Ireland
| | - Brian P. Carson
- Department of Physical Education and Sport Sciences, Faculty of Education and Health Sciences, University of Limerick, V94 T9PX Limerick, Ireland; (A.E.L.); (R.W.D.); (P.M.J.); (T.L.); (J.M.A.)
- Health Research Institute, University of Limerick, V94 T9PX Limerick, Ireland
- Correspondence: ; Tel.: +353-(0)61-234943
| |
Collapse
|
7
|
Lum D, Haff GG, Barbosa TM. The Relationship between Isometric Force-Time Characteristics and Dynamic Performance: A Systematic Review. Sports (Basel) 2020; 8:sports8050063. [PMID: 32429176 PMCID: PMC7281606 DOI: 10.3390/sports8050063] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Revised: 05/09/2020] [Accepted: 05/11/2020] [Indexed: 11/24/2022] Open
Abstract
The purpose of this article was to review the data on the relationship between multi-joint isometric strength test (IsoTest) force-time characteristics (peak force, rate of force development and impulse) and dynamic performance that is available in the current literature. Four electronic databases were searched using search terms related to IsoTest. Studies were considered eligible if they were original research studies that investigated the relationships between multi-joint IsoTest and performance of dynamic movements; published in peer-reviewed journals; had participants who were athletes or active individuals who participate in recreational sports or resistance training, with no restriction on sex; and had full text available. A total of 47 studies were selected. These studies showed significant small to large correlations between isometric bench press (IBP) force-time variables and upper body dynamic performances (r2 = 0.221 to 0.608, p < 0.05) and significant small to very large correlation between isometric squat (ISqT) (r2 = 0.085 to 0.746, p < 0.05) and isometric mid-thigh pull (IMTP) (r2 = 0.120 to 0.941, p < 0.05) force-time variables with lower body dynamic performances. IsoTest force-time characteristics were shown to have small to very large correlations with dynamic performances of the upper and lower limbs as well as performance of sporting movements (r2 = 0.118 to 0.700, p < 0.05). These data suggest that IsoTest force-time characteristics provide insights into the force production capability of athletes which give insight into dynamic performance capabilities.
Collapse
Affiliation(s)
- Danny Lum
- Sport Science and Sport Medicine, Singapore Sport Institute, Singapore 397630, Singapore
- Physical Education and Sports Science National Institute of Education, Nanyang Technological University, Singapore 637616, Singapore;
- Correspondence: ; Tel.: +65-9729-0819
| | - G. Gregory Haff
- Centre for Exercise and Sports Science Research (CESSR), School of Medical and Health Sciences, Edith Cowan University, Joondalup 6027, Australia;
- Directorate of Sports, Exercise and Physiotherapy, University of Salford, Greater Manchester M5 4WT, UK
| | - Tiago M. Barbosa
- Physical Education and Sports Science National Institute of Education, Nanyang Technological University, Singapore 637616, Singapore;
- Department of Sport Sciences, Polytechnic Institute of Bragança, 5300 Bragança, Portugal
- Research Centre in Sports, Health and Human Development (CIDESD), 5001 Vila Real, Portugal
| |
Collapse
|
8
|
Schofield M, Neville J, Hébert-Losier K, Cronin JB, Uthoff AM. Kinematic and kinetic variability associated with the cable put and seated rotation assessments. J Sports Sci 2020; 38:597-606. [PMID: 32005085 DOI: 10.1080/02640414.2020.1721202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
When new protocols are developed, there is a requirement to investigate test-retest reliability of measures for valid use and interpretation of data in research and practice. Therefore, the aim of this investigation was to determine the inter-day reliability of the cable put and seated rotation assessment protocols. On three occasions, nine resistance-trained men performed cable puts and cable rotations at different loads between 6 and 42 kg on a commercially available cable cross over machine. Load stack movement was recorded using a PT5A linear position transducer from which all kinematic and kinetic variables were calculated. Reliability was excellent for peak velocity and displacement based on intraclass correlation coefficient (ICC) and coefficient of variation (CV) across the majority of loads and movements (cable put: ICC = 0.92 to 0.99, CV = 3.1% to 8.6%; cable seated rotation: ICC = 0.76 to 0.99, CV = -1.7% to 16.1%). However, kinetic variables demonstrated inadequate reliability across the majority of days, loads and movements (ICC = 0.70, CV >10%). It was concluded that peak velocity is a reliable kinematic measure to assess muscular capability from cable put and seated rotation protocols; however, kinetic measures are too variable to provide reliable outputs across testing occasions.
Collapse
Affiliation(s)
- Mike Schofield
- School of Sport and Recreation, Auckland University of Technology, Auckland, New Zealand.,High Performance Sport New Zealand, Auckland, New Zealand
| | - Jono Neville
- School of Sport and Recreation, Auckland University of Technology, Auckland, New Zealand
| | - Kim Hébert-Losier
- Health, Sport and Human Performance, University of Waikato, Hamilton, New Zealand
| | - John B Cronin
- School of Sport and Recreation, Auckland University of Technology, Auckland, New Zealand
| | - Aaron M Uthoff
- School of Sport and Recreation, Auckland University of Technology, Auckland, New Zealand
| |
Collapse
|
9
|
Tinsley GM, Moore ML, Graybeal AJ, Paoli A, Kim Y, Gonzales JU, Harry JR, VanDusseldorp TA, Kennedy DN, Cruz MR. Time-restricted feeding plus resistance training in active females: a randomized trial. Am J Clin Nutr 2019; 110:628-640. [PMID: 31268131 PMCID: PMC6735806 DOI: 10.1093/ajcn/nqz126] [Citation(s) in RCA: 118] [Impact Index Per Article: 19.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Revised: 05/10/2019] [Accepted: 05/31/2019] [Indexed: 12/04/2022] Open
Abstract
BACKGROUND A very limited amount of research has examined intermittent fasting (IF) programs, such as time-restricted feeding (TRF), in active populations. OBJECTIVE Our objective was to examine the effects of TRF, with or without β-hydroxy β-methylbutyrate (HMB) supplementation, during resistance training (RT). METHODS This study employed a randomized, placebo-controlled, reduced factorial design and was double-blind with respect to supplementation in TRF groups. Resistance-trained females were randomly assigned to a control diet (CD), TRF, or TRF plus 3 g/d HMB (TRFHMB). TRF groups consumed all calories between 1200 h and 2000 h, whereas the CD group ate regularly from breakfast until the end of the day. All groups completed 8 wk of supervised RT and consumed supplemental whey protein. Body composition, muscular performance, dietary intake, physical activity, and physiological variables were assessed. Data were analyzed prior to unblinding using mixed models and both intention-to-treat (ITT) and per protocol (PP) frameworks. RESULTS Forty participants were included in ITT, and 24 were included in PP. Energy and protein intake (1.6 g/kg/d) did not differ between groups despite different feeding durations (TRF and TRFHMB: ∼7.5 h/d; CD: ∼13 h/d). Comparable fat-free mass (FFM) accretion (+2% to 3% relative to baseline) and skeletal muscle hypertrophy occurred in all groups. Differential effects on fat mass (CD: +2%; TRF: -2% to -4%; TRFHMB: -4% to -7%) were statistically significant in the PP analysis, but not ITT. Muscular performance improved without differences between groups. No changes in physiological variables occurred in any group, and minimal side effects were reported. CONCLUSIONS IF, in the form of TRF, did not attenuate RT adaptations in resistance-trained females. Similar FFM accretion, skeletal muscle hypertrophy, and muscular performance improvements can be achieved with dramatically different feeding programs that contain similar energy and protein content during RT. Supplemental HMB during fasting periods of TRF did not definitively improve outcomes. This study was prospectively registered at clinicaltrials.gov as NCT03404271.
Collapse
Affiliation(s)
- Grant M Tinsley
- Department of Kinesiology and Sport Management, Texas Tech University, Lubbock, TX, USA
| | - M Lane Moore
- Department of Kinesiology and Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Austin J Graybeal
- Department of Kinesiology and Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Antonio Paoli
- Department of Biomedical Sciences, University of Padova, Padova, Italy
| | - Youngdeok Kim
- Department of Kinesiology and Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Joaquin U Gonzales
- Department of Kinesiology and Sport Management, Texas Tech University, Lubbock, TX, USA
| | - John R Harry
- Department of Kinesiology and Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Trisha A VanDusseldorp
- Department of Exercise Science and Sport Management, Kennesaw State University, Kennesaw, GA, USA
| | - Devin N Kennedy
- Department of Kinesiology and Sport Management, Texas Tech University, Lubbock, TX, USA
| | - Megan R Cruz
- Department of Kinesiology and Sport Management, Texas Tech University, Lubbock, TX, USA
| |
Collapse
|
10
|
Tinsley GM, Trexler ET, Smith-Ryan AE, Paoli A, Graybeal AJ, Campbell BI, Schoenfeld BJ. Changes in Body Composition and Neuromuscular Performance Through Preparation, 2 Competitions, and a Recovery Period in an Experienced Female Physique Athlete. J Strength Cond Res 2019; 33:1823-1839. [PMID: 30036283 DOI: 10.1519/jsc.0000000000002758] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Tinsley, GM, Trexler, ET, Smith-Ryan, AE, Paoli, A, Graybeal, AJ, Campbell, BI, and Schoenfeld, BJ. Changes in body composition and neuromuscular performance through preparation, two competitions, and a recovery period in an experienced female physique athlete. J Strength Cond Res 33(7): 1823-1839, 2019-This prospective case study evaluated an experienced female figure competitor during contest preparation, 2 competitions, and a recovery period. Twelve laboratory sessions were conducted over 8 months. At each visit, body composition was assessed by 4-compartment model, resting metabolic rate (RMR) by indirect calorimetry, and neuromuscular performance by peak force and rate of force development (RFD) on a mechanized squat device. Caloric intake ranged from 965 to 1,610 kcal·d (16.1-24.8 kcal·kg·BM; 18.2-31.1 kcal·kg·FFM), with varying macronutrient intakes (CHO: 0.3-4.8 g·kg; PRO: 1.7-3.0 g·kg; and FAT: 0.2-0.5 g·kg). Body fat was reduced from 20.3 to 12.2% before the first competition and declined to 11.6% before the second competition. Fat-free mass increased by 2.1% before the first competition and peaked at 4.6% above baseline in the recovery period. Resting metabolic rate decreased from 1,345 kcal·d at baseline to a low value of 1,119 kcal·d between competitions. By the end of recovery, RMR increased to 1,435 kcal·d. Concentric and eccentric peak forces declined by up to 19% before the first competition, experienced perturbations in the inter-competition and recovery periods, and remained 5-8% below baseline at study termination. Similarly, RFD decreased by up to 57% before the first competition, was partially recovered, but remained 39% lower than baseline at study termination. Despite favorable body composition changes, neuromuscular performance was impaired during and after the competitive season in an experienced female physique competitor.
Collapse
Affiliation(s)
- Grant M Tinsley
- Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, Texas
| | - Eric T Trexler
- Department of Exercise and Sport Science, University of North Carolina, Chapel Hill, North Carolina
| | - Abbie E Smith-Ryan
- Department of Exercise and Sport Science, University of North Carolina, Chapel Hill, North Carolina
| | - Antonio Paoli
- Department of Biomedical Sciences, University of Padova, Padova, Italy
| | - Austin J Graybeal
- Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, Texas
| | - Bill I Campbell
- College of Education, University of South Florida, Tampa, Florida
| | | |
Collapse
|
11
|
Nuzzo JL, Taylor JL, Gandevia SC. CORP: Measurement of upper and lower limb muscle strength and voluntary activation. J Appl Physiol (1985) 2019; 126:513-543. [DOI: 10.1152/japplphysiol.00569.2018] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
Muscle strength, the maximal force-generating capacity of a muscle or group of muscles, is regularly assessed in physiological experiments and clinical trials. An understanding of the expected variation in strength and the factors that contribute to this variation is important when designing experiments, describing methodologies, interpreting results, and attempting to replicate methods of others and reproduce their findings. In this review (Cores of Reproducibility in Physiology), we report on the intra- and inter-rater reliability of tests of upper and lower limb muscle strength and voluntary activation in humans. Isometric, isokinetic, and isoinertial strength exhibit good intra-rater reliability in most samples (correlation coefficients ≥0.90). However, some tests of isoinertial strength exhibit systematic bias that is not resolved by familiarization. With the exception of grip strength, few attempts have been made to examine inter-rater reliability of tests of muscle strength. The acute factors most likely to affect muscle strength and serve as a source of its variation from trial-to-trial or day-to-day include attentional focus, breathing technique, remote muscle contractions, rest periods, temperature (core, muscle), time of day, visual feedback, body and limb posture, body stabilization, acute caffeine consumption, dehydration, pain, fatigue from preceding exercise, and static stretching >60 s. Voluntary activation, the nervous system’s ability to drive a muscle to create its maximal force, exhibits good intra-rater reliability when examined with twitch interpolation (correlation coefficients >0.80). However, inter-rater reliability has not been formally examined. The methodological factors most likely to influence voluntary activation are myograph compliance and sensitivity; stimulation location, intensity, and inadvertent stimulation of antagonists; joint angle (muscle length); and the resting twitch.
Collapse
Affiliation(s)
- James L. Nuzzo
- Neuroscience Research Australia, Randwick, New South Wales, Australia
- School of Medical Sciences, University of New South Wales, Sydney, Australia
| | - Janet L. Taylor
- Neuroscience Research Australia, Randwick, New South Wales, Australia
- School of Medical Sciences, University of New South Wales, Sydney, Australia
- School of Medical and Health Sciences, Edith Cowan University, Perth, Western Australia, Australia
| | - Simon C. Gandevia
- Neuroscience Research Australia, Randwick, New South Wales, Australia
- Prince of Wales Hospital Clinical School, University of New South Wales, Sydney, Australia
| |
Collapse
|
12
|
Drake D, Kennedy RA, Wallace ES. Multi-joint rate of force development testing protocol affects reliability and the smallest detectible difference. J Sports Sci 2019; 37:1570-1581. [PMID: 30810474 DOI: 10.1080/02640414.2019.1576258] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Isometric tests have been used to assess rate of force development (RFD), however variation in testing methodologies are known to affect performance outcomes. The aim of this study was to assess the RFD in the isometric squat (ISqT) using two test protocols and two testing angles. Eleven participants (age: 26.8 ± 4.5 years, strength training experience: 7.1 ± 3.03 years) completed test and retest sessions one week apart, whereby two test protocols with respect to duration and instructions were compared. Isometric peak force (ISqTpeak) and isometric explosive force (ISqTexp) tests were assessed at two joint angles (knee flexion angle 100° and 125°). Force-time traces were sampled and subsequently analysed for RFD measures. Average and instantaneous RFD variables did not meet reliability minimum criteria in ISqTpeak at 100° or 125°. The ISqTexp test at 100° met reliability criteria in the RFD 0-200 and 0-250ms variables. The ISqTexp test at 125° met reliability criteria in the RFD 0-150, 0-200 and 0-250ms variables. Force-time characteristics were optimized at the higher knee joint angle. Average and instantaneous RFD measures obtained using a traditional peak force test do not meet basic reliability criteria. Researchers assessing multi-joint RFD should employ the explosive RFD test protocol as opposed to the traditional isometric peak force protocol.
Collapse
Affiliation(s)
- David Drake
- a School of Sport , Ulster University , Newtownabbey , N. Ireland.,b Ulster Rugby, Irish Rugby Football Union , Belfast , N. Ireland
| | - Rodney A Kennedy
- a School of Sport , Ulster University , Newtownabbey , N. Ireland.,c Sport and Exercise Science Research Institute , Ulster University , Newtownabbey , N. Ireland
| | - Eric S Wallace
- a School of Sport , Ulster University , Newtownabbey , N. Ireland.,c Sport and Exercise Science Research Institute , Ulster University , Newtownabbey , N. Ireland
| |
Collapse
|
13
|
Drake D, Kennedy R, Wallace E. Familiarization, validity and smallest detectable difference of the isometric squat test in evaluating maximal strength. J Sports Sci 2018; 36:2087-2095. [DOI: 10.1080/02640414.2018.1436857] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Affiliation(s)
- David Drake
- School of Sport, Ulster University, N. Ireland
- Ulster Rugby, Irish Rugby Football Union, N. Ireland
| | - Rodney Kennedy
- School of Sport, Ulster University, N. Ireland
- Sport and Exercise Science Research Institute, Ulster University, N. Ireland
| | - Eric Wallace
- School of Sport, Ulster University, N. Ireland
- Sport and Exercise Science Research Institute, Ulster University, N. Ireland
| |
Collapse
|