1
|
Wang W, Qiu F, Han Y, Li X, Komnik I, Viellehner J, Wang S, Potthast W. The effect of marathon running on the lower extremity kinematics and muscle activities during walking and running tasks. J Sports Sci 2024; 42:365-372. [PMID: 38507567 DOI: 10.1080/02640414.2024.2332865] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Accepted: 03/13/2024] [Indexed: 03/22/2024]
Abstract
Patellofemoral pain syndrome (PFPS) is a common injury among runners, and it is thought that abnormal lower extremity biomechanics contribute to its development. However, the relationship between biomechanical changes after a marathon and PFPS injury remains limited. This study aims to investigate whether differences in knee and hip kinematics and lower extremity muscle activities exist in recreational runners before and after a marathon. Additionally, it aims to explore the relationship between these biomechanical changes and the development of PFPS injury. 12 recreational runners participated in the study. Kinematics and muscle activities of the lower extremity were recorded during walking (5 km/h) and running (10 km/h) tasks within 24 hours before and within 5 hours after a marathon. After the marathon, there was a significant decrease in peak knee flexion (walking: p = 0.006; running: p = 0.006) and an increase in peak hip internal rotation (walking: p = 0.026; running: p = 0.015) during the stance phase of both walking and running compared to before the marathon. The study demonstrates a decrease in knee flexion and an increase in hip internal rotation during the stance phase of gait tasks after completing a marathon, which may increase the risk of developing PFPS injury.
Collapse
Affiliation(s)
- Wenjin Wang
- Institute of Biomechanics and Orthopedics, German Sport University Cologne, Cologne, Germany
- Key Laboratory of Exercise and Health Sciences of Ministry of Education, School of Kinesiology, Shanghai University of Sport, Shanghai, China
| | - Fanghui Qiu
- Department of Physical Education, Qingdao University, Qingdao, China
| | - Yongjie Han
- Key Laboratory of Exercise and Health Sciences of Ministry of Education, School of Kinesiology, Shanghai University of Sport, Shanghai, China
- Laboratory of Biomechanics and Engineering, Innomotion, Shanghai, China
| | - Xiangming Li
- Key Laboratory of Exercise and Health Sciences of Ministry of Education, School of Kinesiology, Shanghai University of Sport, Shanghai, China
| | - Igor Komnik
- Institute of Biomechanics and Orthopedics, German Sport University Cologne, Cologne, Germany
| | - Josef Viellehner
- Institute of Biomechanics and Orthopedics, German Sport University Cologne, Cologne, Germany
| | - Shaobai Wang
- Key Laboratory of Exercise and Health Sciences of Ministry of Education, School of Kinesiology, Shanghai University of Sport, Shanghai, China
- Laboratory of Biomechanics and Engineering, Innomotion, Shanghai, China
| | - Wolfgang Potthast
- Institute of Biomechanics and Orthopedics, German Sport University Cologne, Cologne, Germany
| |
Collapse
|
2
|
Encarnación-Martínez A, Sanchis-Sanchis R, Pérez-Soriano P, García-Gallart A. Relationship between muscular extensibility, strength and stability and the transmission of impacts during fatigued running. Sports Biomech 2023; 22:1364-1380. [PMID: 32835623 DOI: 10.1080/14763141.2020.1797863] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2019] [Accepted: 07/14/2020] [Indexed: 10/23/2022]
Abstract
The aim was to analyse the relationship between isokinetic strength, dynamic stability, muscular extensibility and impacts transmission during fatigued running. Low- and high-frequency impacts-related to body movements and the severity of impacts, respectively-were assessed in 17 male recreational runners, before and after a treadmill running fatigue protocol, using a triaxial accelerometry system. High-frequency impacts in the tibia were negatively correlated to the knee angle at which the quadriceps peak torque was reached (p = 0.014), and also to the extensibility of the hamstrings and soleus (p = 0.001 and p = 0.023, respectively). The increases of high-frequency impacts in tibia caused by fatigue were positively related to the knee angle at which the hamstrings peak torque was reached (p = 0.001) and to stability after landing (p = 0.007). The attenuation of high-frequency impacts was positively related to hamstrings/quadriceps ratio of strength (p = 0.010) and to stability (p = 0.006). Limiting possible deficits in hamstring and soleus range of motion, improving stability after landing, developing hamstring and quadriceps strength in elongated muscle range, and maintaining a balanced ratio of hamstring/quadriceps strength could help to reduce the injury risk in running.
Collapse
Affiliation(s)
- Alberto Encarnación-Martínez
- Research Group in Sports Biomechanics, Department of Physical Education and Sports, University of Valencia, Valencia, Spain
| | - Roberto Sanchis-Sanchis
- Research Group in Sports Biomechanics, Department of Physical Education and Sports, University of Valencia, Valencia, Spain
| | - Pedro Pérez-Soriano
- Research Group in Sports Biomechanics, Department of Physical Education and Sports, University of Valencia, Valencia, Spain
| | | |
Collapse
|
3
|
Mason R, Godfrey A, Barry G, Stuart S. Wearables for running gait analysis: A study protocol. PLoS One 2023; 18:e0291289. [PMID: 37695752 PMCID: PMC10495009 DOI: 10.1371/journal.pone.0291289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Accepted: 08/21/2023] [Indexed: 09/13/2023] Open
Abstract
Quantitative running gait analysis is an important tool that provides beneficial outcomes to injury risk/recovery or performance assessment. Wearable devices have allowed running gait to be evaluated in any environment (i.e., laboratory or real-world settings), yet there are a plethora of different grades of devices (i.e., research-grade, commercial, or novel multi-modal) available with little information to make informed decisions on selection. This paper outlines a protocol that will examine different grades of wearables for running gait analysis in healthy individuals. Specifically, this pilot study will: 1) examine analytical validity and reliability of wearables (research-grade, commercial, high-end multimodal) within a controlled laboratory setting; 2) examine analytical validation of different grades of wearables in a real-world setting, and 3) explore clinical validation and usability of wearables for running gait analysis (e.g., injury history (previously injured, never injured), performance level (novice, elite) and relationship to meaningful outcomes). The different grades of wearable include: (1) A research-grade device, the Ax6 consists of a configurable tri-axial accelerometer and tri-axial gyroscope with variable sampling capabilities; (2) attainable (low-grade) commercial with proprietary software, the DorsaVi ViMove2 consisting of two, non-configurable IMUs modules, with a fixed sampling rate and (3) novel multimodal high-end system, the DANU Sports System that is a pair of textile socks, that contain silicone based capacitive pressure sensors, and configurable IMU modules with variable sampling rates. Clinical trial registration: Trial registration: NCT05277181.
Collapse
Affiliation(s)
- Rachel Mason
- Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle, United Kingdom
| | - Alan Godfrey
- Department of Computer and Information Sciences, Northumbria University, Newcastle, United Kingdom
| | - Gillian Barry
- Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle, United Kingdom
| | - Samuel Stuart
- Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle, United Kingdom
- Northumbria Healthcare NHS foundation trust, North Shields, United Kingdom
- Department of Neurology, Oregon Health and Science University, Portland, Oregon, United States of America
| |
Collapse
|
4
|
Mason R, Pearson LT, Barry G, Young F, Lennon O, Godfrey A, Stuart S. Wearables for Running Gait Analysis: A Systematic Review. Sports Med 2023; 53:241-268. [PMID: 36242762 PMCID: PMC9807497 DOI: 10.1007/s40279-022-01760-6] [Citation(s) in RCA: 27] [Impact Index Per Article: 27.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/21/2022] [Indexed: 01/12/2023]
Abstract
BACKGROUND Running gait assessment has traditionally been performed using subjective observation or expensive laboratory-based objective technologies, such as three-dimensional motion capture or force plates. However, recent developments in wearable devices allow for continuous monitoring and analysis of running mechanics in any environment. Objective measurement of running gait is an important (clinical) tool for injury assessment and provides measures that can be used to enhance performance. OBJECTIVES We aimed to systematically review the available literature investigating how wearable technology is being used for running gait analysis in adults. METHODS A systematic search of the literature was conducted in the following scientific databases: PubMed, Scopus, Web of Science and SPORTDiscus. Information was extracted from each included article regarding the type of study, participants, protocol, wearable device(s), main outcomes/measures, analysis and key findings. RESULTS A total of 131 articles were reviewed: 56 investigated the validity of wearable technology, 22 examined the reliability and 77 focused on applied use. Most studies used inertial measurement units (n = 62) [i.e. a combination of accelerometers, gyroscopes and magnetometers in a single unit] or solely accelerometers (n = 40), with one using gyroscopes alone and 31 using pressure sensors. On average, studies used one wearable device to examine running gait. Wearable locations were distributed among the shank, shoe and waist. The mean number of participants was 26 (± 27), with an average age of 28.3 (± 7.0) years. Most studies took place indoors (n = 93), using a treadmill (n = 62), with the main aims seeking to identify running gait outcomes or investigate the effects of injury, fatigue, intrinsic factors (e.g. age, sex, morphology) or footwear on running gait outcomes. Generally, wearables were found to be valid and reliable tools for assessing running gait compared to reference standards. CONCLUSIONS This comprehensive review highlighted that most studies that have examined running gait using wearable sensors have done so with young adult recreational runners, using one inertial measurement unit sensor, with participants running on a treadmill and reporting outcomes of ground contact time, stride length, stride frequency and tibial acceleration. Future studies are required to obtain consensus regarding terminology, protocols for testing validity and the reliability of devices and suitability of gait outcomes. CLINICAL TRIAL REGISTRATION CRD42021235527.
Collapse
Affiliation(s)
- Rachel Mason
- Department of Sport, Exercise and Rehabilitation, Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK
| | - Liam T Pearson
- Department of Sport, Exercise and Rehabilitation, Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK
| | - Gillian Barry
- Department of Sport, Exercise and Rehabilitation, Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK
| | - Fraser Young
- Department of Computer and Information Sciences, Northumbria University, Newcastle upon Tyne, UK
| | | | - Alan Godfrey
- Department of Computer and Information Sciences, Northumbria University, Newcastle upon Tyne, UK
| | - Samuel Stuart
- Department of Sport, Exercise and Rehabilitation, Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK.
- Northumbria Healthcare NHS Foundation Trust, Newcastle upon Tyne, UK.
| |
Collapse
|
5
|
Cartón-Llorente A, Roche-Seruendo LE, Mainer-Pardos E, Nobari H, Rubio-Peirotén A, Jaén-Carrillo D, García-Pinillos F. Acute effects of a 60-min time trial on power-related parameters in trained endurance runners. BMC Sports Sci Med Rehabil 2022; 14:142. [PMID: 35871673 PMCID: PMC9310469 DOI: 10.1186/s13102-022-00538-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Accepted: 07/20/2022] [Indexed: 11/10/2022] Open
Abstract
Background The advent of power meters for running has raised the interest of athletes and coaches in new ways of assessing changes in running performance. The aim of this study is to determine the changes in power-related variables during and after a strenuous endurance running time trial.
Methods Twenty-one healthy male endurance runners, with a personal record of 37.2 ± 1.2 min in a 10-km race, completed a 1-h run on a motorized treadmill trying to cover as much distance as they could. Before and after the time trial the athletes were asked to perform a 3-min run at 12 km h−1. Normalized mean power output, step frequency, form power and running effectiveness were calculated using the Stryd™ power meter. Heart rate (HR) and rating of perceived exertion (RPE) were monitored, and data averaged every 5 min. Results Despite high levels of exhaustion were reached during the time trial (HRpeak = 176.5 ± 9.8 bpm; RPE = 19.2 ± 0.8), the repeated measures ANOVA resulted in no significant differences (p ≥ 0.05), between each pair of periods for any of the power-related variables. The pairwise comparison (T test) between the non-fatigued and fatigued constant 3-min runs showed an increase in step frequency (p = 0.012) and a decrease in form power (p < 0.001) under fatigue conditions, with no meaningful changes in normalized mean power output and running effectiveness. Conclusions Trained athletes are able to maintain power output and running effectiveness during a high demanding extended run. However, they preferred to reduce the intensity of vertical impacts under fatigue conditions by increasing their step frequency.
Collapse
|
6
|
Preatoni E, Bergamini E, Fantozzi S, Giraud LI, Orejel Bustos AS, Vannozzi G, Camomilla V. The Use of Wearable Sensors for Preventing, Assessing, and Informing Recovery from Sport-Related Musculoskeletal Injuries: A Systematic Scoping Review. SENSORS (BASEL, SWITZERLAND) 2022; 22:3225. [PMID: 35590914 PMCID: PMC9105988 DOI: 10.3390/s22093225] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 04/13/2022] [Accepted: 04/18/2022] [Indexed: 02/06/2023]
Abstract
Wearable technologies are often indicated as tools that can enable the in-field collection of quantitative biomechanical data, unobtrusively, for extended periods of time, and with few spatial limitations. Despite many claims about their potential for impact in the area of injury prevention and management, there seems to be little attention to grounding this potential in biomechanical research linking quantities from wearables to musculoskeletal injuries, and to assessing the readiness of these biomechanical approaches for being implemented in real practice. We performed a systematic scoping review to characterise and critically analyse the state of the art of research using wearable technologies to study musculoskeletal injuries in sport from a biomechanical perspective. A total of 4952 articles were retrieved from the Web of Science, Scopus, and PubMed databases; 165 were included. Multiple study features-such as research design, scope, experimental settings, and applied context-were summarised and assessed. We also proposed an injury-research readiness classification tool to gauge the maturity of biomechanical approaches using wearables. Five main conclusions emerged from this review, which we used as a springboard to propose guidelines and good practices for future research and dissemination in the field.
Collapse
Affiliation(s)
- Ezio Preatoni
- Department for Health, University of Bath, Bath BA2 7AY, UK; (E.P.); (L.I.G.)
- Centre for Health and Injury and Illness Prevention in Sport, University of Bath, Bath BA2 7AY, UK
| | - Elena Bergamini
- Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy; (E.B.); (A.S.O.B.); (V.C.)
- Interuniversity Centre of Bioengineering of the Human Neuromusculoskeletal System (BOHNES), University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy
| | - Silvia Fantozzi
- Department of Electrical, Electronic, and Information Engineering “Guglielmo Marconi”, University of Bologna, Viale Risorgimento 2, 40136 Bologna, Italy;
- Health Sciences and Technologies—Interdepartmental Centre for Industrial Research, University of Bologna, Viale Risorgimento 2, 40136 Bologna, Italy
| | - Lucie I. Giraud
- Department for Health, University of Bath, Bath BA2 7AY, UK; (E.P.); (L.I.G.)
| | - Amaranta S. Orejel Bustos
- Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy; (E.B.); (A.S.O.B.); (V.C.)
- Interuniversity Centre of Bioengineering of the Human Neuromusculoskeletal System (BOHNES), University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy
| | - Giuseppe Vannozzi
- Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy; (E.B.); (A.S.O.B.); (V.C.)
- Interuniversity Centre of Bioengineering of the Human Neuromusculoskeletal System (BOHNES), University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy
| | - Valentina Camomilla
- Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy; (E.B.); (A.S.O.B.); (V.C.)
- Interuniversity Centre of Bioengineering of the Human Neuromusculoskeletal System (BOHNES), University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy
| |
Collapse
|
7
|
Benson LC, Räisänen AM, Clermont CA, Ferber R. Is This the Real Life, or Is This Just Laboratory? A Scoping Review of IMU-Based Running Gait Analysis. SENSORS 2022; 22:s22051722. [PMID: 35270869 PMCID: PMC8915128 DOI: 10.3390/s22051722] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Revised: 02/16/2022] [Accepted: 02/17/2022] [Indexed: 01/19/2023]
Abstract
Inertial measurement units (IMUs) can be used to monitor running biomechanics in real-world settings, but IMUs are often used within a laboratory. The purpose of this scoping review was to describe how IMUs are used to record running biomechanics in both laboratory and real-world conditions. We included peer-reviewed journal articles that used IMUs to assess gait quality during running. We extracted data on running conditions (indoor/outdoor, surface, speed, and distance), device type and location, metrics, participants, and purpose and study design. A total of 231 studies were included. Most (72%) studies were conducted indoors; and in 67% of all studies, the analyzed distance was only one step or stride or <200 m. The most common device type and location combination was a triaxial accelerometer on the shank (18% of device and location combinations). The most common analyzed metric was vertical/axial magnitude, which was reported in 64% of all studies. Most studies (56%) included recreational runners. For the past 20 years, studies using IMUs to record running biomechanics have mainly been conducted indoors, on a treadmill, at prescribed speeds, and over small distances. We suggest that future studies should move out of the lab to less controlled and more real-world environments.
Collapse
Affiliation(s)
- Lauren C. Benson
- Faculty of Kinesiology, University of Calgary, Calgary, AB T2N 1N4, Canada; (A.M.R.); (C.A.C.); (R.F.)
- Tonal Strength Institute, Tonal, San Francisco, CA 94107, USA
- Correspondence:
| | - Anu M. Räisänen
- Faculty of Kinesiology, University of Calgary, Calgary, AB T2N 1N4, Canada; (A.M.R.); (C.A.C.); (R.F.)
- Department of Physical Therapy Education, College of Health Sciences—Northwest, Western University of Health Sciences, Lebanon, OR 97355, USA
| | - Christian A. Clermont
- Faculty of Kinesiology, University of Calgary, Calgary, AB T2N 1N4, Canada; (A.M.R.); (C.A.C.); (R.F.)
- Sport Product Testing, Canadian Sport Institute Calgary, Calgary, AB T3B 6B7, Canada
| | - Reed Ferber
- Faculty of Kinesiology, University of Calgary, Calgary, AB T2N 1N4, Canada; (A.M.R.); (C.A.C.); (R.F.)
- Cumming School of Medicine, Faculty of Nursing, University of Calgary, Calgary, AB T2N 1N4, Canada
- Running Injury Clinic, Calgary, AB T2N 1N4, Canada
| |
Collapse
|
8
|
Aristizábal Pla G, Hollville E, Schütte K, Vanwanseele B. The Use of a Single Trunk-Mounted Accelerometer to Detect Changes in Center of Mass Motion Linked to Lower-Leg Overuse Injuries: A Prospective Study. SENSORS 2021; 21:s21217385. [PMID: 34770692 PMCID: PMC8588413 DOI: 10.3390/s21217385] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 10/27/2021] [Accepted: 10/27/2021] [Indexed: 11/27/2022]
Abstract
Movement dynamics during running was previously characterized using a trunk-mounted accelerometer, and were associated with a history of overuse injuries. However, it remains unknown if these measures are also linked to the development of overuse injuries. The aim of this study was therefore to determine how movement dynamics alter in response to fatigue, and the possible link with developing lower-leg overuse injuries during a six-month follow-up period. Two hundred and eight movement science university students completed a 12-min all-out run while wearing a trunk-mounted accelerometer. Dynamic stability, dynamic loading and spatiotemporal measures were extracted from the accelerometer. Participants sustaining an injury within the 6-month period demonstrated significantly higher RMS ratio values in the vertical direction and lower RMS ratio values in the anteroposterior direction, and lower impact acceleration values in the anteroposterior direction in an unfatigued state compared to the uninjured group. They also demonstrated an increase in dynamic loading in the horizontal plane during the run. In addition, with running fatigue both groups exhibited changes in dynamic stability and loading measures. These results show the potential of using a single trunk-mounted accelerometer to detect changes in movement dynamics that are linked to lower-leg overuse injuries.
Collapse
Affiliation(s)
- Gerard Aristizábal Pla
- Human Movements Biomechanics Research Group, Department of Movement Sciences, KU Leuven, 3001 Leuven, Belgium; (G.A.P.); (E.H.); (K.S.)
- Department of Kinesiology, UMASS Amherst Amherst, University of Massachusetts Integrative Locomotion Lab, Amherst, MA 01003, USA
| | - Enzo Hollville
- Human Movements Biomechanics Research Group, Department of Movement Sciences, KU Leuven, 3001 Leuven, Belgium; (G.A.P.); (E.H.); (K.S.)
| | - Kurt Schütte
- Human Movements Biomechanics Research Group, Department of Movement Sciences, KU Leuven, 3001 Leuven, Belgium; (G.A.P.); (E.H.); (K.S.)
| | - Benedicte Vanwanseele
- Human Movements Biomechanics Research Group, Department of Movement Sciences, KU Leuven, 3001 Leuven, Belgium; (G.A.P.); (E.H.); (K.S.)
- Correspondence:
| |
Collapse
|
9
|
Martínez-Navarro I, Montoya-Vieco A, Hernando C, Hernando B, Panizo N, Collado E. The week after running a marathon: Effects of running vs elliptical training vs resting on neuromuscular performance and muscle damage recovery. Eur J Sport Sci 2021; 21:1668-1674. [PMID: 33251988 DOI: 10.1080/17461391.2020.1857441] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Our aim was to compare the effects of two exercise modalities vs resting on the time course of neuromuscular performance and muscle damage recovery during the week after running a marathon. Sixty-four finishers from a road marathon completed the study (54 men and 10 women; 39 ± 4 years; 3 h 35 min ± 21 min). The day before the race, within 15 min after finishing the marathon and at 24, 48, 96, 144 and 192 h postrace, lactate dehydrogenase and creatine kinase were analysed. Participants also performed a squat jump (SJ) test before and after the marathon and at 48, 96 and 144 h postrace. On their arrival to the finish line, participants were randomized into one of the three intervention groups: running (RUN), elliptical training (ELIP) and resting recovery (REST). RUN and ELIP groups exercised continuously for 40 min at a moderate intensity (95-105% of the HR corresponding to the first ventilatory threshold) at 48, 96 and 144 h after the marathon. Neither 'Intervention' factor nor 'Intervention x Time' interaction effects were revealed for muscle damage blood markers (p > 0.05). On the other hand, RUN group evidenced an enhancement in SJ performance 96 h post-marathon as compared with REST group (108.29 ± 10.64 vs 100.58 ± 9.16%, p = 0.020, d = 0.80). Consequently, return to running at 48 h post-marathon does not seem to have a negative impact on muscle damage recovery up to eight days post-race and it could be recommended in order to speed up neuromuscular recovery.
Collapse
Affiliation(s)
- I Martínez-Navarro
- Physical Education and Sports Department, University of Valencia, Valencia, Spain.,Sports Health Unit, Vithas 9 de Octubre Hospital, Valencia, Spain
| | - A Montoya-Vieco
- Physical Education and Sports Department, University of Valencia, Valencia, Spain.,Sports Health Unit, Vithas 9 de Octubre Hospital, Valencia, Spain
| | - C Hernando
- Sport Service, Jaume I University, Castellon, Spain.,Department of Education and Specific Didactics, Jaume I University, Castellon, Spain
| | - B Hernando
- Department of Medicine, Jaume I University, Castellon, Spain
| | - N Panizo
- Department of Medicine, Jaume I University, Castellon, Spain.,Universitary Clinical Hospital of Valencia, Valencia, Spain
| | - E Collado
- Faculty of Health Sciences, Jaume I University, Castellon, Spain
| |
Collapse
|
10
|
Estimating Lower Extremity Running Gait Kinematics with a Single Accelerometer: A Deep Learning Approach. SENSORS 2020; 20:s20102939. [PMID: 32455927 PMCID: PMC7287664 DOI: 10.3390/s20102939] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Revised: 05/01/2020] [Accepted: 05/20/2020] [Indexed: 11/16/2022]
Abstract
Abnormal running kinematics are associated with an increased incidence of lower extremity injuries among runners. Accurate and unobtrusive running kinematic measurement plays an important role in the detection of gait abnormalities and the prevention of injuries among runners. Inertial-based methods have been proposed to address this need. However, previous methods require cumbersome sensor setup or participant-specific calibration. This study aims to validate a shoe-mounted accelerometer for sagittal plane lower extremity angle measurement during running based on a deep learning approach. A convolutional neural network (CNN) architecture was selected as the regression model to generalize in inter-participant scenarios and to minimize poorly estimated joints. Motion and accelerometer data were recorded from ten participants while running on a treadmill at five different speeds. The reference joint angles were measured by an optical motion capture system. The CNN model predictions deviated from the reference angles with a root mean squared error (RMSE) of less than 3.5° and 6.5° in intra- and inter-participant scenarios, respectively. Moreover, we provide an estimation of six important gait events with a mean absolute error of less than 2.5° and 6.5° in intra- and inter-participants scenarios, respectively. This study highlights an appealing minimal sensor setup approach for gait analysis purposes.
Collapse
|