1
|
Nakanishi T, Hirose M, Asada Y, Itoh S. Legionella community dynamics in a drinking water distribution system: Impact of residual chlorine depletion. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 956:177302. [PMID: 39488281 DOI: 10.1016/j.scitotenv.2024.177302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2024] [Revised: 10/08/2024] [Accepted: 10/28/2024] [Indexed: 11/04/2024]
Abstract
This study investigated the occurrence of Legionella spp. in a chlorinated drinking water distribution system (DWDS), focusing on their community compositions and association with physicochemical water quality. Water samples were collected throughout the DWDS, covering from the treated water reservoir to distal ends. Although Legionella spp. genes were not detected at the reservoir, their abundance dramatically increased along the distribution network, reaching up to 4.4 log copies/L at distal sites. The Legionella communities were further characterized by high-throughput amplicon sequencing targeting the genus-specific 16S rRNA gene. The results revealed a diverse Legionella community, including amplicon sequence variants with high similarity (> 99 %) to potentially pathogenic species such as L. drozanskii and L. pneumophila, albeit at low levels. Moreover, Legionella community diversity increased significantly along the distribution system, leading to distinct community compositions at distal sites. Importantly, decay of residual chlorine concentration was identified as a key factor both in increasing the Legionella gene levels and shaping the community structure. Overall, this study underscores the importance of preventing pipe corrosion and maintaining adequate disinfectant residuals to minimize Legionella regrowth in DWDS.
Collapse
Affiliation(s)
- Tomohiro Nakanishi
- Department of Environmental Engineering, Graduate School of Engineering, Kyoto University, Kyoto University Katsura, Nishikyo, Kyoto 615-8540, Japan.
| | - Madoka Hirose
- Department of Environmental Engineering, Graduate School of Engineering, Kyoto University, Kyoto University Katsura, Nishikyo, Kyoto 615-8540, Japan
| | - Yasuhiro Asada
- Research Center for Environmental Quality Management, Graduate School of Engineering, Kyoto University, Yumihama 1-2, Otsu, Shiga 520-0811, Japan; Department of Environmental Health, National Institute of Public Health, 2-3-6 Minami, Wako, Saitama 351-0197, Japan
| | - Sadahiko Itoh
- Department of Environmental Engineering, Graduate School of Engineering, Kyoto University, Kyoto University Katsura, Nishikyo, Kyoto 615-8540, Japan
| |
Collapse
|
2
|
Furst KE, Graham KE, Weisman RJ, Adusei KB. It's getting hot in here: Effects of heat on temperature, disinfection, and opportunistic pathogens in drinking water distribution systems. WATER RESEARCH 2024; 260:121913. [PMID: 38901309 DOI: 10.1016/j.watres.2024.121913] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Revised: 06/06/2024] [Accepted: 06/07/2024] [Indexed: 06/22/2024]
Abstract
As global temperatures rise with climate change, the negative effects of heat on drinking water distribution systems (DWDS) are of increasing concern. High DWDS temperatures are associated with degradation of water quality through physical, chemical and microbial mechanisms. Perhaps the most pressing concern is proliferation of thermotolerant opportunistic pathogens (OPs) like Legionella pneumophila and Naegleria Fowleri. Many OPs can be controlled in DWDS by residual disinfectants such as chlorine or chloramine, but maintaining protective residuals can be challenging at high temperatures. This critical review evaluates the literature on DWDS temperature, residual disinfectant decay, and OP survival and growth with respect to high temperatures. The findings are synthesized to determine the state of knowledge and future research priorities regarding OP proliferation and control at high DWDS temperatures. Temperatures above 40 °C were reported from multiple DWDS, with a maximum of 52 °C. Substantial diurnal temperature swings from ∼30-50 °C occurred in one DWDS. Many OPs can survive or even replicate at these temperatures. However, most studies focused on just a few OP species, and substantial knowledge gaps remain regarding persistence, infectivity, and shifts in microbial community structure at high temperatures relative to lower water temperatures. Chlorine decay rates substantially increase with temperature in some waters but not in others, for reasons that are not well understood. Decay rates within real DWDS are difficult to accurately characterize, presenting practical limitations for application of temperature-dependent decay models at full scale. Chloramine decay is slower than chlorine except in the presence of nitrifiers, which are especially known to grow in DWDS in warmer seasons and climates, though the high temperature range for nitrification is unknown. Lack of knowledge about DWDS nitrifier communities may hinder development of solutions. Fundamental knowledge gaps remain which prevent understanding even the occurrence of high temperatures in DWDS, much less the overall effect on exposure risk. Potential solutions to minimize DWDS temperatures or mitigate the impacts of heat were identified, many which could be aided by proven models for predicting DWDS temperature. Industry leadership and collaboration is needed to generate practical knowledge for protecting DWDS water quality as temperatures rise.
Collapse
Affiliation(s)
- Kirin E Furst
- Department of Civil, Environmental, & Infrastructure Engineering, George Mason University, 4400 University Drive, Fairfax, VA 22030, United States.
| | - Katherine E Graham
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, GA 30332, United States
| | - Richard J Weisman
- Department of Civil, Environmental, & Infrastructure Engineering, George Mason University, 4400 University Drive, Fairfax, VA 22030, United States
| | - Kadmiel B Adusei
- Department of Civil, Environmental, & Infrastructure Engineering, George Mason University, 4400 University Drive, Fairfax, VA 22030, United States
| |
Collapse
|
3
|
Dallalana ES, Monteiro RM, Oliveira VDC, Bim FL, Bim LL, Castro DT, Macedo AP, Watanabe E. The long-term effect of sub-boiling water on dental unit waterlines and its ability to control cross-contamination in dentistry. Dent Mater J 2023; 42:700-707. [PMID: 37612094 DOI: 10.4012/dmj.2023-051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/25/2023]
Abstract
This study investigated the effect of water at high temperature on the physical and mechanical properties of polyurethane and on biofilm removal, aiming for its applicability in dental unit waterlines. The evaluations were carried out after simulating a 1-year period of daily immersion and measured changes in color, microhardness, surface roughness, and tensile strength before and after reproducing a disinfection protocol. For antibiofilm activity measurement, fragments of waterline were contaminated with Pseudomonas aeruginosa and submitted to the disinfection protocols. Relative to effects on the physical and mechanical properties, immersion in water at 60°C did not promote changes in color and tensile strength. However, lower values were observed for microhardness and increased values for surface roughness. Regarding antibiofilm action, water at 60°C significantly reduced the microbial load and promoted substantial changes in cells morphology. In conclusion, disinfection with water at 60°C demonstrated possible application in controlling cross-contamination in dentistry.
Collapse
Affiliation(s)
- Erick Silva Dallalana
- Human Exposome and Infectious Diseases Network (HEID), School of Nursing of Ribeirão Preto, University of São Paulo
| | - Rachel Maciel Monteiro
- Human Exposome and Infectious Diseases Network (HEID), School of Nursing of Ribeirão Preto, University of São Paulo
| | - Viviane de Cássia Oliveira
- Human Exposome and Infectious Diseases Network (HEID), School of Nursing of Ribeirão Preto, University of São Paulo
- Department of Dental Materials and Prostheses, School of Dentistry of Ribeirão Preto, University of São Paulo
| | - Felipe Lazarini Bim
- Human Exposome and Infectious Diseases Network (HEID), School of Nursing of Ribeirão Preto, University of São Paulo
| | - Lucas Lazarini Bim
- Human Exposome and Infectious Diseases Network (HEID), School of Nursing of Ribeirão Preto, University of São Paulo
| | | | - Ana Paula Macedo
- Department of Dental Materials and Prostheses, School of Dentistry of Ribeirão Preto, University of São Paulo
| | - Evandro Watanabe
- Human Exposome and Infectious Diseases Network (HEID), School of Nursing of Ribeirão Preto, University of São Paulo
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo
| |
Collapse
|
4
|
van der Wielen PWJJ, Dignum M, Donocik A, Prest EI. Influence of Temperature on Growth of Four Different Opportunistic Pathogens in Drinking Water Biofilms. Microorganisms 2023; 11:1574. [PMID: 37375076 DOI: 10.3390/microorganisms11061574] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 06/08/2023] [Accepted: 06/10/2023] [Indexed: 06/29/2023] Open
Abstract
High drinking water temperatures occur due to climate change and could enhance the growth of opportunistic pathogens in drinking water systems. We investigated the influence of drinking water temperatures on the growth of Pseudomonas aeruginosa, Stenotrophomonas maltophilia, Mycobacterium kansasii and Aspergillus fumigatus in drinking water biofilms with an autochthonous microflora. Our results reveal that the growth of P. aeruginosa and S. maltophilia in the biofilm already occurred at 15.0 °C, whereas M. kansasii and A. fumigatus were able to grow when temperatures were above 20.0 °C and 25.0 °C, respectively. Moreover, the maximum growth yield of P. aeruginosa, M. kansasii and A. fumigatus increased with increasing temperatures up to 30 °C, whereas an effect of temperature on the yield of S. maltophilia could not be established. In contrast, the maximum ATP concentration of the biofilm decreased with increasing temperatures. We conclude from these results that high drinking water temperatures caused by, e.g., climate change can result in high numbers of P. aeruginosa, M. kansasii and A. fumigatus in drinking water systems, which poses a possible risk to public health. Consequently, it is recommended for countries with a more moderate climate to use or maintain a drinking water maximum standard temperature of 25 °C.
Collapse
Affiliation(s)
- Paul W J J van der Wielen
- KWR Water Research Institute, 3433 PE Nieuwegein, The Netherlands
- Laboratory of Microbiology, Wageningen University & Research, 6708 WE Wageningen, The Netherlands
| | | | | | | |
Collapse
|
5
|
De Giglio O, D’Ambrosio M, Spagnuolo V, Diella G, Fasano F, Leone CM, Lopuzzo M, Trallo V, Calia C, Oliva M, Pazzani C, Iacumin L, Barigelli S, Petricciuolo M, Federici E, Lisena FP, Minicucci AM, Montagna MT. Legionella anisa or Legionella bozemanii? Traditional and molecular techniques as support in the environmental surveillance of a hospital water network. ENVIRONMENTAL MONITORING AND ASSESSMENT 2023; 195:496. [PMID: 36947259 PMCID: PMC10033568 DOI: 10.1007/s10661-023-11078-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Accepted: 03/02/2023] [Indexed: 06/18/2023]
Abstract
Understanding the actual distribution of different Legionella species in water networks would help prevent outbreaks. Culture investigations followed by serological agglutination tests, with poly/monovalent antisera, still represent the gold standard for isolation and identification of Legionella strains. However, also MALDI-TOF and mip-gene sequencing are currently used. This study was conducted to genetically correlate strains of Legionella non pneumophila (L-np) isolated during environmental surveillance comparing different molecular techniques. Overall, 346 water samples were collected from the water system of four pavilions located in a hospital of the Apulia Region of Italy. Strains isolated from the samples were then identified by serological tests, MALDI-TOF, and mip-gene sequencing. Overall, 24.9% of water samples were positive for Legionella, among which the majority were Legionella pneumophila (Lpn) 1 (52.3%), followed by Lpn2-15 (20.9%), L-np (17.4%), Lpn1 + Lpn2-15 (7.1%), and L-np + Lpn1 (2.3%). Initially, L-np strains were identified as L. bozemanii by monovalent antiserum, while MALDI-TOF and mip-gene sequencing assigned them to L. anisa. More cold water than hot water samples were contaminated by L. anisa (p < 0.001). PFGE, RAPD, Rep-PCR, and SAU-PCR were performed to correlate L. anisa strains. Eleven out of 14 strains identified in all four pavilions showed 100% of similarity upon PFGE analysis. RAPD, Rep-PCR, and SAU-PCR showed greater discriminative power than PFGE.
Collapse
Affiliation(s)
- Osvalda De Giglio
- Interdisciplinary Department of Medicine, Section of Hygiene, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Marilena D’Ambrosio
- Department of Biomedical Sciences and Human Oncology, Section of Hygiene, Medical School, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Valentina Spagnuolo
- Department of Biomedical Sciences and Human Oncology, Section of Hygiene, Medical School, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Giusy Diella
- Interdisciplinary Department of Medicine, Section of Hygiene, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Fabrizio Fasano
- Interdisciplinary Department of Medicine, Section of Hygiene, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Carla Maria Leone
- Present Address: Section Hygiene - AOU Policlinico of Bari, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Marco Lopuzzo
- Department of Biomedical Sciences and Human Oncology, Section of Hygiene, Medical School, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Valeria Trallo
- Present Address: Section Hygiene - AOU Policlinico of Bari, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Carla Calia
- Department of Biology, University of Bari Aldo Moro, Via Orabona 4, 70126 Bari, Italy
| | - Marta Oliva
- Department of Biology, University of Bari Aldo Moro, Via Orabona 4, 70126 Bari, Italy
| | - Carlo Pazzani
- Department of Biology, University of Bari Aldo Moro, Via Orabona 4, 70126 Bari, Italy
| | - Lucilla Iacumin
- Department of Agricultural, Food, Environmental and Animal Science, University of Udine, Via Sondrio 2/a, 33100 Udine, Italy
| | - Sofia Barigelli
- Department of Chemistry, Biology and Biotechnology, University of Perugia, Via del Giochetto, 06122 Perugia, Italy
| | - Maya Petricciuolo
- Department of Chemistry, Biology and Biotechnology, University of Perugia, Via del Giochetto, 06122 Perugia, Italy
| | - Ermanno Federici
- Department of Chemistry, Biology and Biotechnology, University of Perugia, Via del Giochetto, 06122 Perugia, Italy
| | | | - Anna Maria Minicucci
- Health Management, A.O.U. Policlinico of Bari, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Maria Teresa Montagna
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Interdisciplinary Department of Medicine, Section of Hygiene, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124 Bari, Italy
| |
Collapse
|
6
|
Four-Year Environmental Surveillance Program of Legionella spp. in One of Palermo’s Largest Hospitals. Microorganisms 2022; 10:microorganisms10040764. [PMID: 35456814 PMCID: PMC9030258 DOI: 10.3390/microorganisms10040764] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Revised: 03/25/2022] [Accepted: 03/28/2022] [Indexed: 02/05/2023] Open
Abstract
Legionella is a ubiquitous bacterium that lives in freshwater environments and colonizes human-made water systems. Legionella pneumophila is the most virulent species, and risk factors for Legionnaires’ disease include increasing age, smoking, chronic diseases, and immunodeficiency. For this reason, it is very important to assess and monitor hospital water systems in order to prevent legionellosis. We have monitored a large hospital in Palermo for four years. To determine the presence of microorganisms, according to national guidelines, we used the culture method, which is considered the gold standard for Legionella detection. Sampling was divided into five macro-areas, and a total of 251 samples were collected during the period of investigation, 49% of which were Legionella spp.-positive and 51% were Legionella spp.-negative. Positive samples with L. pneumophila. sgr 2-15 were most frequent in the Underground (55.6%, p = 0.0184), Medicine (42.9%, p = 0.0184) and Other (63.2%, p = 0.002) areas; while positive samples for L. pneumophila sgr 1 were less frequent in the Underground (0.0%, p = 0.0184) and Surgery areas (4.5%, p = 0.033), and for Legionella anisa, were less frequent in the Medicine (4.1%, p = 0.021), Oncohematology (0.0%, p = 0.0282), and Other (0.0%, p = 0.016) areas. Finally, no significant differences were observed among the areas for each isolate considered. The surveillance carried out in these years demonstrates the importance of monitoring, which allows us to analyze the conditions of hospital facilities and, therefore, prevent Legionella spp. infections.
Collapse
|
7
|
Cazals M, Bédard E, Doberva M, Faucher S, Prévost M. Compromised Effectiveness of Thermal Inactivation of Legionella pneumophila in Water Heater Sediments and Water, and Influence of the Presence of Vermamoeba vermiformis. Microorganisms 2022; 10:microorganisms10020443. [PMID: 35208896 PMCID: PMC8874534 DOI: 10.3390/microorganisms10020443] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Revised: 02/04/2022] [Accepted: 02/09/2022] [Indexed: 11/21/2022] Open
Abstract
Intermittent reduction of temperature set-points and periodic shutdowns of water heaters have been proposed to reduce energy consumption in buildings. However, the consequences of such measures on the occurrence and proliferation of Legionella pneumophila (Lp) in hot water systems have not been documented. The impact of single and repeated heat shocks was investigated using an environmental strain of L. pneumophila and a reference strain of V. vermiformis. Heat shocks at temperatures ranging from 50 °C to 70 °C were applied for 1 h and 4 h in water and water heaters loose deposits (sludge). The regrowth potential of heat-treated culturable L. pneumophila in presence of V. vermiformis in water heaters sludges was evaluated. A 2.5-log loss of culturability of L. pneumophila was observed in simulated drinking water at 60 °C while a 4-log reduction was reached in water heaters loose deposits. Persistence of Lp after 4 h at 55 °C was shown and the presence of V. vermiformis in water heater’s loose deposits resulted in a drastic amplification (5-log). Results show that thermal inactivation by heat shock is only efficient at elevated temperatures (50 °C) in both water and loose deposits. The few remaining organisms can rapidly proliferate during storage at lower temperature in the presence of hosts.
Collapse
Affiliation(s)
- Margot Cazals
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC H3C 3A7, Canada; (E.B.); (M.D.); (M.P.)
- Correspondence:
| | - Emilie Bédard
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC H3C 3A7, Canada; (E.B.); (M.D.); (M.P.)
| | - Margot Doberva
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC H3C 3A7, Canada; (E.B.); (M.D.); (M.P.)
| | - Sébastien Faucher
- Department of Natural Resource Sciences, Faculty of Agricultural and Environmental Sciences, McGill University, Sainte-Anne-de-Bellevue, QC H9X 3V9, Canada;
| | - Michèle Prévost
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC H3C 3A7, Canada; (E.B.); (M.D.); (M.P.)
| |
Collapse
|
8
|
Rasheduzzaman M, Singh R, Haas CN, Gurian PL. Required water temperature in hotel plumbing to control Legionella growth. WATER RESEARCH 2020; 182:115943. [PMID: 32590203 DOI: 10.1016/j.watres.2020.115943] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Revised: 05/12/2020] [Accepted: 05/13/2020] [Indexed: 05/07/2023]
Abstract
Legionella spp. occurring in hotel hot water systems, in particular Legionella pneumophila, are causing serious pneumonic infections, and water temperature is a key factor to control their occurrence in plumbing systems. We performed a systematic review and meta-analyses of the available evidence on the association between water temperature and Legionella colonization to identify the water temperature in hotel hot water systems required for control of Legionella. Qualitative synthesis and quantitative analysis were performed on 13 studies that met our inclusion criteria to identify the effect of temperature. The Receiver Operating Characteristic (ROC) curve identified 55 °C as a cutoff point for hotel hot water temperature with an Area Under the Curve (AUC) value of 0.914. The odds ratios (OR) for detecting Legionella at temperatures >55 °C compared to lower temperatures from a meta-analysis of three studies was 0.17 [95% CI: 0.11, 0.25], which indicates a strong negative association between temperature and Legionella colonization. A logistic regression on results from multiple studies using both molecular and culture methods found a temperature of 59 °C associated with an 8% probability of detectable Legionella. Only two studies reported sufficiently detailed data to allow a model of concentration vs. temperature to be fit, and this model was not statistically significant. Additional research or more detailed reporting of existing datasets is required to assess if Legionella growth can be limited below particular concentration targets at different temperatures.
Collapse
Affiliation(s)
- Md Rasheduzzaman
- Department of Civil, Architectural and Environmental Engineering, Drexel University, 3141 Chestnut Street, Philadelphia, PA, 19104, USA.
| | - Rajveer Singh
- Department of Civil, Architectural and Environmental Engineering, Drexel University, 3141 Chestnut Street, Philadelphia, PA, 19104, USA
| | - Charles N Haas
- Department of Civil, Architectural and Environmental Engineering, Drexel University, 3141 Chestnut Street, Philadelphia, PA, 19104, USA
| | - Patrick L Gurian
- Department of Civil, Architectural and Environmental Engineering, Drexel University, 3141 Chestnut Street, Philadelphia, PA, 19104, USA
| |
Collapse
|
9
|
Oh Y, Noga R, Shanov V, Ryu H, Chandra H, Yadav B, Yadav J, Chae S. Electrically heatable carbon nanotube point-of-use filters for effective separation and in-situ inactivation of Legionella pneumophila. CHEMICAL ENGINEERING JOURNAL (LAUSANNE, SWITZERLAND : 1996) 2019; 366:21-26. [PMID: 31275054 PMCID: PMC6604856 DOI: 10.1016/j.cej.2019.02.054] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Despite municipal chlorination and secondary disinfection, opportunistic waterborne pathogens (e.g., Legionella spp.) persist in public and private water distribution systems. As a potential source of healthcare-acquired infections, this warrants development of novel pathogen removal and inactivation systems. In this study, electrically heatable carbon nanotube (CNT) point-of-use (POU) filters have been designed to remove and inactivate Legionella pneumophila in water. The CNT/polymer composite membranes effectively removed Legionella (> 99.99%) (i.e., below detection limit) and were able to inactive them on the membrane surface at 100% efficiency within 60 s using ohmic heating at 20 V. The novel POU filters could be used as a final barrier to provide efficient rejection of pathogens and thereby simultaneously eliminate microorganisms in public and private water supplies.
Collapse
Affiliation(s)
- Yoontaek Oh
- Department of Chemical and Environmental Engineering, University of Cincinnati, Cincinnati, OH 45221, U.S.A
| | - Ryan Noga
- Department of Chemical and Environmental Engineering, University of Cincinnati, Cincinnati, OH 45221, U.S.A
| | - Vesselin Shanov
- Department of Chemical and Environmental Engineering, University of Cincinnati, Cincinnati, OH 45221, U.S.A
| | - Hodon Ryu
- National Risk Management Research Laboratory, U.S. Environmental Protection Agency, Cincinnati, OH 45268, U.S.A
| | - Harish Chandra
- Microbial Pathogenesis and Immunotoxicology Laboratory, Department of Environmental Health, University of Cincinnati, Cincinnati, OH 45267, U.S.A
| | - Brijesh Yadav
- Microbial Pathogenesis and Immunotoxicology Laboratory, Department of Environmental Health, University of Cincinnati, Cincinnati, OH 45267, U.S.A
| | - Jagjit Yadav
- Microbial Pathogenesis and Immunotoxicology Laboratory, Department of Environmental Health, University of Cincinnati, Cincinnati, OH 45267, U.S.A
| | - Soryong Chae
- Department of Chemical and Environmental Engineering, University of Cincinnati, Cincinnati, OH 45221, U.S.A
| |
Collapse
|
10
|
Primary Colonizing Betaproteobacteriales Play a Key Role in the Growth of Legionella pneumophila in Biofilms on Surfaces Exposed to Drinking Water Treated by Slow Sand Filtration. Appl Environ Microbiol 2018; 84:AEM.01732-18. [PMID: 30291115 DOI: 10.1128/aem.01732-18] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Accepted: 09/28/2018] [Indexed: 02/05/2023] Open
Abstract
Slow sand filtration with extensive pretreatment reduces the microbial growth potential of drinking water to a minimum level at four surface water supplies in The Netherlands. The potential of these slow sand filtrates (SSFs) to promote microbial growth in warm tap water installations was assessed by measuring biofilm formation and growth of Legionella bacteria on glass and chlorinated polyvinylchloride (CPVC) surfaces exposed to SSFs at 37 ± 2°C in a model system for up to six months. The steady-state biofilm concentration ranged from 230 to 3,980 pg ATP cm-2 on glass and 1.4 (±0.3)-times-higher levels on CPVC. These concentrations correlated significantly with the assimilable organic carbon (AOC) concentrations of the warm water (8 to 24 µg acetate-C equivalents [ac-C eq] liter-1), which were raised about 2 times by mixing cold and heated (70°C) SSFs. All biofilms supported growth of Legionella pneumophila with maximum concentrations ranging from 6 × 102 to 1.5 × 105 CFU cm-2 Biofilms after ≤50 days of exposure were predominated by Betaproteobacteriales, mainly Piscinibacter, Caldimonas, Methyloversatilis, and an uncultured Rhodocyclaceae bacterium. These rapidly growing primary colonizers most likely served as prey for the host amoebae of L. pneumophila Alphaproteobacteria, mostly Xanthobacteraceae, e.g., Bradyrhizobium, Pseudorhodoplanes, and other amoeba-resistant bacteria, accounted for 37.5% of the clones retrieved. A conceptual model based on a quadratic relationship between the L. pneumophila colony count and the biofilm concentration under steady-state conditions is used to explain the variations in the Legionella CFU pg-1 ATP ratios in the biofilms.IMPORTANCE Proliferation of L. pneumophila in premise plumbing poses a public health threat. Extended water treatment using physicochemical and biofiltration processes, including slow sand filtration, at four surface water supplies in The Netherlands reduces the microbial growth potential of the treated water to a minimum level, and the distributed drinking water complies with high quality standards. However, heating of the water in warm tap water installations increases the concentration of easily assimilable organic compounds, thereby promoting biofilm formation and growth of L. pneumophila Prevention of biofilm formation in plumbing systems by maintenance of a disinfectant residual during distribution and/or further natural organic matter (NOM) removal is not feasible in the supplies studied. Temperature management in combination with optimized hydraulics and material selection are therefore essential to prevent growth of L. pneumophila in premise plumbing systems. Still, reducing the concentration of biodegradable compounds in drinking water by appropriate water treatment is important for limiting the Legionella growth potential.
Collapse
|
11
|
Veenendaal HR, Brouwer-Hanzens AJ, van der Kooij D. Incubation of premise plumbing water samples on Buffered Charcoal Yeast Extract agar at elevated temperature and pH selects for Legionella pneumophila. WATER RESEARCH 2017; 123:439-447. [PMID: 28689128 DOI: 10.1016/j.watres.2017.06.077] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2016] [Revised: 05/30/2017] [Accepted: 06/26/2017] [Indexed: 06/07/2023]
Abstract
Worldwide, over 90% of the notified cases of Legionnaires' disease are caused by Legionella pneumophila. However, the standard culture medium for the detection of Legionella in environmental water samples, Buffered Charcoal Yeast Extract (BCYE) agar of pH 6.9 ± 0.4 with or without antimicrobial agents incubated at 36 ± 1 °C, supports the growth of a large diversity of Legionella species. BCYE agar of elevated pH or/and incubation at elevated temperature gave strongly reduced recoveries of most of 26 L. non-pneumophila spp. tested, but not of L. pneumophila. BCYE agar of pH 7.3 ± 0.1, incubated at 40 ± 0.5 °C (BCYE pH 7.3/40 °C) was tested for selective enumeration of L. pneumophila. Of the L. non-pneumophila spp. tested, only L. adelaidensis and L. londiniensis multiplied under these conditions. The colony counts on BCYE pH 7.3/40 °C of a L. pneumophila serogroup 1 strain cultured in tap water did not differ significantly from those on BCYE pH 6.9/36 °C when directly plated and after membrane filtration and showed repeatability's of 13-14%. By using membrane filtration L. pneumophila was detected in 58 (54%) of 107 Legionella-positive water samples from premise plumbing systems under one or both of these culture conditions. The L. pneumophila colony counts (log-transformed) on BCYE pH 7.3/40 °C were strongly related (r2 = 0.87) to those on BCYE pH 6.9/36 °C, but differed significantly (p < 0.05) by a mean of - 0.12 ± 0.30 logs. L. non-pneumophila spp. were detected only on BCYE pH 6.9/36 °C in 49 (46%) of the samples. Hence, BCYE pH 7.3/40 °C can facilitate the enumeration of L. pneumophila and their isolation from premise plumbing systems with culturable L. non-pneumophila spp., some of which, e.g. L. anisa, can be present in high numbers.
Collapse
Affiliation(s)
- Harm R Veenendaal
- KWR Watercycle Research Institute, PO Box 1072, 3430 BB, Nieuwegein, The Netherlands
| | | | - Dick van der Kooij
- KWR Watercycle Research Institute, PO Box 1072, 3430 BB, Nieuwegein, The Netherlands.
| |
Collapse
|
12
|
van der Kooij D, Bakker GL, Italiaander R, Veenendaal HR, Wullings BA. Biofilm Composition and Threshold Concentration for Growth of Legionella pneumophila on Surfaces Exposed to Flowing Warm Tap Water without Disinfectant. Appl Environ Microbiol 2017; 83:e02737-16. [PMID: 28062459 PMCID: PMC5311405 DOI: 10.1128/aem.02737-16] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2016] [Accepted: 12/13/2016] [Indexed: 02/07/2023] Open
Abstract
Legionella pneumophila in potable water installations poses a potential health risk, but quantitative information about its replication in biofilms in relation to water quality is scarce. Therefore, biofilm formation on the surfaces of glass and chlorinated polyvinyl chloride (CPVC) in contact with tap water at 34 to 39°C was investigated under controlled hydraulic conditions in a model system inoculated with biofilm-grown L. pneumophila The biofilm on glass (average steady-state concentration, 23 ± 9 pg ATP cm-2) exposed to treated aerobic groundwater (0.3 mg C liter-1; 1 μg assimilable organic carbon [AOC] liter-1) did not support growth of the organism, which also disappeared from the biofilm on CPVC (49 ± 9 pg ATP cm-2) after initial growth. L. pneumophila attained a level of 4.3 log CFU cm-2 in the biofilms on glass (1,055 ± 225 pg ATP cm-2) and CPVC (2,755 ± 460 pg ATP cm-2) exposed to treated anaerobic groundwater (7.9 mg C liter-1; 10 μg AOC liter-1). An elevated biofilm concentration and growth of L. pneumophila were also observed with tap water from the laboratory. The Betaproteobacteria Piscinibacter and Methyloversatilis and amoeba-resisting Alphaproteobacteria predominated in the clones and isolates retrieved from the biofilms. In the biofilms, the Legionella colony count correlated significantly with the total cell count (TCC), heterotrophic plate count, ATP concentration, and presence of Vermamoeba vermiformis This amoeba was rarely detected at biofilm concentrations of <100 pg ATP cm-2 A threshold concentration of approximately 50 pg ATP cm-2 (TCC = 1 × 106 to 2 × 106 cells cm-2) was derived for growth of L. pneumophila in biofilms.IMPORTANCELegionella pneumophila is the etiologic agent in more than 10,000 cases of Legionnaires' disease that are reported annually worldwide and in most of the drinking water-associated disease outbreaks reported in the United States. The organism proliferates in biofilms on surfaces exposed to warm water in engineered freshwater installations. An investigation with a test system supplied with different types of warm drinking water without disinfectant under controlled hydraulic conditions showed that treated aerobic groundwater (0.3 mg liter-1 of organic carbon) induced a low biofilm concentration that supported no or very limited growth of L. pneumophila Elevated biofilm concentrations and L. pneumophila colony counts were observed on surfaces exposed to two types of extensively treated groundwater, containing 1.8 and 7.9 mg C liter-1 and complying with the microbial water quality criteria during distribution. Control measures in warm tap water installations are therefore essential for preventing growth of L. pneumophila.
Collapse
Affiliation(s)
| | | | | | | | - Bart A Wullings
- KWR Watercycle Research Institute, Nieuwegein, the Netherlands
| |
Collapse
|