1
|
Monistero V, Vicari N, Prati P, Bragoni R, Gazzola A, Sala L, Maisano A, Moroni P, Bronzo V, Luini MV, Castiglioni B, Cremonesi P. A rapid and reliable method for early Legionella pneumophila identification and characterization in support of the epidemiology study. Front Microbiol 2024; 15:1452861. [PMID: 39439937 PMCID: PMC11495126 DOI: 10.3389/fmicb.2024.1452861] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2024] [Accepted: 09/17/2024] [Indexed: 10/25/2024] Open
Abstract
Introduction Legionnaires' disease is a severe pneumonia predominantly caused by Legionella pneumophila (Lp), whose major reservoirs are artificial water systems. As most human infections are caused by L. pneumophila serogroup 1 (Lp1), a reliable method for Lp distinction can be crucial for bacterial spread prevention. As the ability to withstand in environments and to cause the waterborne disease is strongly related to specific genes, the identification of virulent strains can be of great relevance to implement water environmental monitoring and to contain harmful outbreaks to public health. We aimed to test an assay for Lp identification among different Legionella species, and to determine the serogroups. Additionally, we investigated the carriage of virulence and antimicrobial resistance genes. Methods A total of 90 Legionella spp. isolates identified by phenotypic tests were subjected to the designed quantitative PCR assay targeting specific mip for Lp, wzm for Lp1, pvcA and ahpD for biofilm production. Eleven serogroups were investigated in all our isolates tested positive for mip gene, subsequently analyzed for 12 virulence and 8 antimicrobial resistance genes. Results Only the 70 Lp isolates were positive for mip. Out of 27 Lp isolates belonging to serogroup 1 based on agglutination test, 23 (85.2%) carried wzm. The presence of ahpD and pvcA was found in 94.3 and 98.6% of Lp isolates, respectively. By multiplex PCR, all 23 wzm-positive strains were confirmed as serogroup 1 that was the most predominant (33%). At least one virulence gene was detected in all Lp isolates. The most frequent gene was ispE (100%), followed by issD (96%), icmK and enhC (93%), cpxA (91%), rtxA2 (74%), lvhB8-B9 (61%), and prpA (54%). The other genes were less diffused in Lp strains (rtxA1, 44%; lvhB3-B4, 47%; pvcB, 27%; lvrE, 24%). Of the macrolide resistance genes, the ereA was found in 84% of Lp strains, while only 14 (20%) harbored the lpeAB among the efflux pump genes. Conclusion The assays validated in this study enable the simultaneous Lp and Lp1 detection. The differentiation of Lp strains according to their virulence properties could be useful to predict the bacterial ability to survive and to cause the disease.
Collapse
Affiliation(s)
- Valentina Monistero
- Department of Veterinary Medicine and Animal Sciences - DIVAS, University of Milan, Lodi, Italy
- Laboratorio di Malattie Infettive degli Animali - MiLab, University of Milan, Lodi, Italy
| | - Nadia Vicari
- Diagnostic Section of Pavia, Istituto Zooprofilattico Sperimentale della Lombardia e dell’Emilia-Romagna - IZSLER, Pavia, Italy
| | - Paola Prati
- Diagnostic Section of Pavia, Istituto Zooprofilattico Sperimentale della Lombardia e dell’Emilia-Romagna - IZSLER, Pavia, Italy
| | - Roldano Bragoni
- Diagnostic Section of Pavia, Istituto Zooprofilattico Sperimentale della Lombardia e dell’Emilia-Romagna - IZSLER, Pavia, Italy
| | - Alessandra Gazzola
- Diagnostic Section of Lodi, Istituto Zooprofilattico Sperimentale della Lombardia e dell’Emilia-Romagna - IZSLER, Lodi, Italy
| | - Lorenza Sala
- Diagnostic Section of Lodi, Istituto Zooprofilattico Sperimentale della Lombardia e dell’Emilia-Romagna - IZSLER, Lodi, Italy
| | - Antonio Maisano
- Diagnostic Section of Lodi, Istituto Zooprofilattico Sperimentale della Lombardia e dell’Emilia-Romagna - IZSLER, Lodi, Italy
| | - Paolo Moroni
- Department of Veterinary Medicine and Animal Sciences - DIVAS, University of Milan, Lodi, Italy
- Laboratorio di Malattie Infettive degli Animali - MiLab, University of Milan, Lodi, Italy
| | - Valerio Bronzo
- Department of Veterinary Medicine and Animal Sciences - DIVAS, University of Milan, Lodi, Italy
- Laboratorio di Malattie Infettive degli Animali - MiLab, University of Milan, Lodi, Italy
| | - Mario Vittorio Luini
- Institute of Agricultural Biology and Biotechnology – IBBA-CNR, National Research Council, Lodi, Italy
| | - Bianca Castiglioni
- Institute of Agricultural Biology and Biotechnology – IBBA-CNR, National Research Council, Lodi, Italy
| | - Paola Cremonesi
- Institute of Agricultural Biology and Biotechnology – IBBA-CNR, National Research Council, Lodi, Italy
| |
Collapse
|
2
|
Fan S, Shen Y, Qian L. Social life of free-living amoebae in aquatic environment- comprehensive insights into interactions of free-living amoebae with neighboring microorganisms. Front Microbiol 2024; 15:1382075. [PMID: 38962117 PMCID: PMC11220160 DOI: 10.3389/fmicb.2024.1382075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Accepted: 06/03/2024] [Indexed: 07/05/2024] Open
Abstract
Free-living amoebae (FLA) are prevalent in nature and man-made environments, and they can survive in harsh conditions by forming cysts. Studies have discovered that some FLA species are able to show pathogenicity to human health, leading to severe infections of central nervous systems, eyes, etc. with an extremely low rate of recovery. Therefore, it is imperative to establish a surveillance framework for FLA in environmental habitats. While many studies investigated the risks of independent FLA, interactions between FLA and surrounding microorganisms determined microbial communities in ecosystems and further largely influenced public health. Here we systematically discussed the interactions between FLA and different types of microorganisms and corresponding influences on behaviors and health risks of FLA in the environment. Specifically, bacteria, viruses, and eukaryotes can interact with FLA and cause either enhanced or inhibited effects on FLA infectivity, along with microorganism community changes. Therefore, considering the co-existence of FLA and other microorganisms in the environment is of great importance for reducing environmental health risks.
Collapse
Affiliation(s)
| | | | - Li Qian
- Department of Civil and Environmental Engineering, School of Engineering and Applied Science, The George Washington University, Washington, DC, United States
| |
Collapse
|
3
|
Abstract
Legionella pneumophila (LP) widely exists in natural and artificial water environments, which facilitates LP to infect people. LP infection causes Legionnaires' disease (LD), which is an important but relatively uncommon respiratory infection. Approximately 90% of LD is caused by L. pneumophila serogroup 1 (Lp1). Meteorological conditions may affect the infectivity and virulence of Lp1, but the exact relationship between them is still unclear. In this study, we evaluated the virulence of Lp1 by screening of total 156 Lp1 strains isolated from cooling tower water in different region of China by detecting their abilities to activate NF-κB signaling pathway in vitro. In addition, we screened the distribution of some selected virulence genes in these strains. The virulence, virulence gene distribution and the meteorological factors were analyzed. We found that both the virulence and the distribution of virulence genes had a certain regional and meteorological correlation. Although loss of several virulence genes showed significant effects on the virulence of Lp1 strains, the distribution of virulence genes had very limited effects on the virulence of Lp1. IMPORTANCE LD is likely to be under-recognized in many countries. Due to the widespread existence of LP in natural and artificial water environments, and to the lack of cross-protection against different strains, LP is a potentially serious threat to human health. Therefore, effective monitoring of the virulence of LP in the water environment is very important to prevent and control the prevalence of LD. Understanding the virulence of LP can not only help us to predict the risk of possible outbreaks in advance, but can also enable more targeted clinical treatment. This study highlights the importance of understanding the epidemiology and ecology of LP isolated from public facilities in terms of public health and biology. Due to the potential for water sources to harbor and disseminate LP, and to the fact that geographical conditions influence the virulence of LP, timely and accurate LP virulence surveillance is urgently needed.
Collapse
|
4
|
Mameri RM, Bodennec J, Bezin L, Demanèche S. Mitigation of Expression of Virulence Genes in Legionella pneumophila Internalized in the Free-Living Amoeba Willaertia magna C2c Maky. Pathogens 2020; 9:pathogens9060447. [PMID: 32517040 PMCID: PMC7350332 DOI: 10.3390/pathogens9060447] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Revised: 05/29/2020] [Accepted: 06/03/2020] [Indexed: 12/11/2022] Open
Abstract
Legionella pneumophila is a human pathogen responsible for a severe form of pneumonia named Legionnaire disease. Its natural habitat is aquatic environments, being in a free state or intracellular parasites of free-living amoebae, such as Acanthamoeba castellanii. This pathogen is able to replicate within some amoebae. Willaertia magna C2c Maky, a non-pathogenic amoeba, was previously demonstrated to resist to L. pneumophila and even to be able to eliminate the L. pneumophila strains Philadelphia, Lens, and Paris. Here, we studied the induction of seven virulence genes of three L. pneumophila strains (Paris, Philadelphia, and Lens) within W. magna C2c Maky in comparison within A. castellanii and with the gene expression level of L. pneumophila strains alone used as controls. We defined a gene expression-based virulence index to compare easily and without bias the transcript levels in different conditions and demonstrated that W. magna C2c Maky did not increase the virulence of L. pneumophila strains in contrast to A. castellanii. These results confirmed the non-permissiveness of W. magna C2c Maky toward L. pneumophila strains.
Collapse
Affiliation(s)
| | - Jacques Bodennec
- Lyon Neuroscience Research Center CRNL UMR5292 U1028, University of Lyon, Univ Lyon 1, CNRS, Inserm, 69500 Bron, France; (J.B.); (L.B.)
| | - Laurent Bezin
- Lyon Neuroscience Research Center CRNL UMR5292 U1028, University of Lyon, Univ Lyon 1, CNRS, Inserm, 69500 Bron, France; (J.B.); (L.B.)
| | - Sandrine Demanèche
- R&D Department, Amoéba, 69680 Chassieu, France;
- Correspondence: ; Tel.: +33-(04)-2669-1600
| |
Collapse
|
5
|
Rattanakul S, Oguma K. Inactivation kinetics and efficiencies of UV-LEDs against Pseudomonas aeruginosa, Legionella pneumophila, and surrogate microorganisms. WATER RESEARCH 2018; 130:31-37. [PMID: 29195159 DOI: 10.1016/j.watres.2017.11.047] [Citation(s) in RCA: 112] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2017] [Revised: 11/18/2017] [Accepted: 11/23/2017] [Indexed: 05/26/2023]
Abstract
To demonstrate the effectiveness of UV light-emitting diodes (UV-LEDs) to disinfect water, UV-LEDs at peak emission wavelengths of 265, 280, and 300 nm were adopted to inactivate pathogenic species, including Pseudomonas aeruginosa and Legionella pneumophila, and surrogate species, including Escherichia coli, Bacillus subtilis spores, and bacteriophage Qβ in water, compared to conventional low-pressure UV lamp emitting at 254 nm. The inactivation profiles of each species showed either a linear or sigmoidal survival curve, which both fit well with the Geeraerd's model. Based on the inactivation rate constant, the 265-nm UV-LED showed most effective fluence, except for with E. coli which showed similar inactivation rates at 265 and 254 nm. Electrical energy consumption required for 3-log10 inactivation (EE,3) was lowest for the 280-nm UV-LED for all microbial species tested. Taken together, the findings of this study determined the inactivation profiles and kinetics of both pathogenic bacteria and surrogate species under UV-LED exposure at different wavelengths. We also demonstrated that not only inactivation rate constants, but also energy efficiency should be considered when selecting an emission wavelength for UV-LEDs.
Collapse
Affiliation(s)
- Surapong Rattanakul
- Research Center for Advanced Science and Technology, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8904, Japan
| | - Kumiko Oguma
- Research Center for Advanced Science and Technology, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8904, Japan.
| |
Collapse
|
6
|
Blanky M, Sharaby Y, Rodríguez-Martínez S, Halpern M, Friedler E. Greywater reuse - Assessment of the health risk induced by Legionella pneumophila. WATER RESEARCH 2017; 125:410-417. [PMID: 28889040 DOI: 10.1016/j.watres.2017.08.068] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2017] [Revised: 08/20/2017] [Accepted: 08/25/2017] [Indexed: 06/07/2023]
Abstract
Greywater (GW), domestic wastewater excluding the streams generated by toilets and kitchens, can serve as an alternative water source. The main options for GW reuse are toilet flushing and garden irrigation, both generating aerosols. These may transmit inhalable pathogens like Legionella and present a potential health risk. This study quantified the health risk that may arise from inhalation of Legionella-contaminated aerosols due to non-potable GW reuse. Data on Legionella concentrations in potable water and GW was collected. Then, Quantitative Microbial Risk Assessment (QMRA) was performed for two possible exposure scenarios: garden irrigation and toilet flushing. This was performed while considering Legionella seasonality. In order to determine the safety of GW reuse regarding Legionella transmission, the obtained results were compared with estimated tolerable risk levels of infection and of disease. Both limits were expressed as Disability-Adjusted Life Years index (DALY) being 10-4 and 10-5, respectively. The QMRA revealed that the annual risk associated with reuse of treated and chlorinated GW for garden irrigation and toilet flushing was not significantly higher than the risk associated with using potable water for the same two purposes. In all studied scenarios, the health risk stemming from reusing treated and chlorinated GW was acceptable regarding Legionella infection. In contrast, reuse of untreated or treated but unchlorinated GW should not be practiced, as these are associated with significantly higher health risks.
Collapse
Affiliation(s)
- Marina Blanky
- Faculty of Civil and Environmental Engineering, Technion, Haifa, Israel
| | - Yehonatan Sharaby
- Department of Evolutionary and Environmental Biology, Faculty of Natural Sciences, University of Haifa, Haifa, Israel
| | - Sara Rodríguez-Martínez
- Department of Evolutionary and Environmental Biology, Faculty of Natural Sciences, University of Haifa, Haifa, Israel
| | - Malka Halpern
- Department of Evolutionary and Environmental Biology, Faculty of Natural Sciences, University of Haifa, Haifa, Israel; Department of Biology and Environment, Faculty of Natural Sciences, University of Haifa, Oranim, Tivon, Israel.
| | - Eran Friedler
- Faculty of Civil and Environmental Engineering, Technion, Haifa, Israel
| |
Collapse
|
7
|
Dobrowsky PH, Khan S, Khan W. Resistance of Legionella and Acanthamoeba mauritaniensis to heat treatment as determined by relative and quantitative polymerase chain reactions. ENVIRONMENTAL RESEARCH 2017; 158:82-93. [PMID: 28609649 DOI: 10.1016/j.envres.2017.06.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2017] [Revised: 05/11/2017] [Accepted: 06/04/2017] [Indexed: 06/07/2023]
Abstract
Legionella and Acanthamoeba spp. persist in harvested rainwater pasteurized at high temperatures (> 72°C) and the interaction mechanisms exhibited between these organisms need to be elucidated. The resistance of two Legionella reference strains (Legionella pneumophila ATCC 33152 and Legionella longbeachae ATCC 33462), three environmental strains [Legionella longbeachae (env.), Legionella norrlandica (env.) and Legionella rowbothamii (env.)] and Acanthamoeba mauritaniensis ATCC 50676 to heat treatment (50-90°C) was determined by monitoring culturability and viability [ethidium monoazide quantitative polymerase chain reaction (EMA-qPCR)]. The expression of metabolic and virulence genes of L. pneumophila ATCC 33152 (lolA, sidF, csrA) and L. longbeachae (env.) (lolA) in co-culture with A. mauritaniensis ATCC 50676 during heat treatment (50-90°C) was monitored using relative qPCR. While the culturability (CFU/mL) and viability (gene copies/mL) of the Legionella strains reduced significantly (p < 0.05) following heat treatment (60-90°C), L. longbeachae (env.) and L. pneumophila ATCC 33152 were culturable following heat treatment at 50-60°C. Metabolically active trophozoites and dormant cysts of A. mauritaniensis ATCC 50676 were detected at 50°C and 60-90°C, respectively. For L. pneumophila ATCC 33152, lolA expression remained constant, sidF expression increased and the expression of csrA decreased during co-culture with A. mauritaniensis ATCC 50676. For L. longbeachae (env.), while lolA was up-regulated at 50-70°C, expression was not detected at 80-90°C and in co-culture. In conclusion, while heat treatment may reduce the number of viable Legionella spp. in monoculture, results indicate that the presence of A. mauritaniensis increases the virulence of L. pneumophila during heat treatment. The virulence of Legionella spp. in co-culture with Acanthamoeba spp. should thus be monitored in water distribution systems where temperature (heat) is utilized for treatment.
Collapse
Affiliation(s)
- Penelope H Dobrowsky
- Department of Microbiology, Faculty of Science, Stellenbosch University, Private Bag X1, Stellenbosch 7602, South Africa.
| | - Sehaam Khan
- Faculty of Health and Applied Sciences, Namibia University of Science and Technology,13 Storch Street, Private Bag 13388, Windhoek, Namibia.
| | - Wesaal Khan
- Department of Microbiology, Faculty of Science, Stellenbosch University, Private Bag X1, Stellenbosch 7602, South Africa.
| |
Collapse
|
8
|
Shen Y, Huang C, Lin J, Wu W, Ashbolt NJ, Liu WT, Nguyen TH. Effect of Disinfectant Exposure on Legionella pneumophila Associated with Simulated Drinking Water Biofilms: Release, Inactivation, and Infectivity. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2017; 51:2087-2095. [PMID: 28085262 DOI: 10.1021/acs.est.6b04754] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Legionella pneumophila, the most commonly identified causative agent in drinking water associated with disease outbreaks, can be harbored by and released from drinking water biofilms. In this study, the release of biofilm-associated L. pneumophila under simulated drinking water flow containing a disinfectant residual was examined. Meanwhile, the inactivation and infectivity (to amoebae) of the released L. pneumophila were studied. To simulate drinking water system conditions, biofilms were prepared under either disinfectant exposure (predisinfected biofilms) or disinfectant-free (untreated biofilms) conditions, respectively. For experiments with water flow containing a disinfectant to release the biofilm-associated L. pneumophila from these two types of biofilms, the L. pneumophila release kinetics values from predisinfected and untreated biofilms under flow condition were not statistically different (one-way ANOVA, p > 0.05). However, inactivation of the L. pneumophila released from predisinfected biofilms was 1-2 times higher and amoeba infectivity was 2-29 times lower than that from untreated biofilms. The higher disinfectant resistance of L. pneumophila released from untreated biofilms was presumably influenced by the detachment of a larger amount of biofilm material (determined by 16S rRNA qPCR) surrounding the released L. pneumophila. This study highlights the interaction among disinfectant residual, biofilms, and L. pneumophila, which provides guidelines to assess and control pathogen risk.
Collapse
Affiliation(s)
- Yun Shen
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign , Urbana, Illinois 61801-2352, United States
| | - Conghui Huang
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign , Urbana, Illinois 61801-2352, United States
| | - Jie Lin
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign , Urbana, Illinois 61801-2352, United States
| | - Wenjing Wu
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign , Urbana, Illinois 61801-2352, United States
| | - Nicholas J Ashbolt
- School of Public Health, University of Alberta , Edminton, Alberta AB T6G 2G7, Canada
| | - Wen-Tso Liu
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign , Urbana, Illinois 61801-2352, United States
| | - Thanh H Nguyen
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign , Urbana, Illinois 61801-2352, United States
| |
Collapse
|
9
|
Short-term effects of atmospheric pressure, temperature, and rainfall on notification rate of community-acquired Legionnaires' disease in four European countries. Epidemiol Infect 2016; 144:3483-3493. [PMID: 27572105 PMCID: PMC5111125 DOI: 10.1017/s0950268816001874] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
Legionnaires' disease (LD) is caused by the inhalation of aerosols containing Legionella, a Gram-negative bacteria. Previous national- or regional-level studies have suggested an impact of climate on LD incidence. The objective of this study was to investigate the effect of temperature, rainfall, and atmospheric pressure on short-term variations in LD notification rate. EU/EEA Member States report their LD surveillance data to the European Centre for Disease Prevention and Control. Community-acquired LD cases reported by Denmark, Germany, Italy, and The Netherlands with onset date in 2007-2012 were aggregated by onset week and region of residence. Weather variables were extracted from the European Climate Assessment & Dataset project. We fitted Poisson regression models to estimate the association between meteorological variables and the weekly number of community-acquired LD cases. Temperature, rainfall and atmospheric pressure were all associated with LD risk with higher risk associated with simultaneous increase in temperature and rainfall. Temperatures >20 °C were not associated with a higher risk for LD. LD cases occurring during wintertime may be associated with sources less influenced by meteorological conditions.
Collapse
|
10
|
Sente C, Erume J, Naigaga I, Mulindwa J, Ochwo S, Magambo PK, Namara BG, Kato CD, Sebyatika G, Muwonge K, Ocaido M. Prevalence of pathogenic free-living amoeba and other protozoa in natural and communal piped tap water from Queen Elizabeth protected area, Uganda. Infect Dis Poverty 2016; 5:68. [PMID: 27485513 PMCID: PMC4971666 DOI: 10.1186/s40249-016-0162-5] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2015] [Accepted: 06/22/2016] [Indexed: 12/14/2022] Open
Abstract
Background Pathogenic water dwelling protozoa such as Acanthamoeba spp., Hartmannella spp., Naegleria spp., Cryptosporidium spp. and Giardia spp. are often responsible for devastating illnesses especially in children and immunocompromised individuals, yet their presence and prevalence in certain environment in sub-Saharan Africa is still unknown to most researchers, public health officials and medical practitioners. The objective of this study was to establish the presence and prevalence of pathogenic free-living amoeba (FLA), Cryptosporidium and Giardia in Queen Elizabeth Protected Area (QEPA). Methods Samples were collected from communal taps and natural water sites in QEPA. Physical water parameters were measured in situ. The samples were processed to detect the presence of FLA trophozoites by xenic cultivation, Cryptosporidium oocysts by Ziehl-Neelsen stain and Giardia cysts by Zinc Sulphate floatation technique. Parasites were observed microscopically, identified, counted and recorded. For FLA, genomic DNA was extracted for amplification and sequencing. Results Both natural and tap water sources were contaminated with FLA, Cryptosporidium spp. and Giardia spp. All protozoan parasites were more abundant in the colder rainy season except for Harmannella spp. and Naegleria spp. which occurred more in the warmer months. The prevalence of all parasites was higher in tap water than in natural water samples. There was a strong negative correlation between the presence of Acanthamoeba spp., Hartmannella spp., Cryptosporidium spp. and Giardia spp. with Dissolved Oxygen (DO) (P < 0.05). The presence of Cryptosporidium spp. showed a significant positive correlation (P < 0.05) with conductivity, pH and Total Dissolved Solids (TDS); whereas the presence of Giardia spp. had only a strong positive correlation with TDS. Molecular genotyping of FLA produced 7 Acanthamoeba, 5 Echinamoeba, 2 Hartmannella, 1 Bodomorpha, 1 Nuclearia and 1 Cercomonas partial sequences. Conclusions All water collection sites were found to be contaminated with pathogenic protozoa that could possibly be the cause of a number of silent morbidities and mortalities among rural households in QEPA. This implies that water used by communities in QEPA is of poor quality and predisposes them to a variety of protozoan infections including the FLA whose public health importance was never reported, thus necessitating adoption of proper water safety measures. Electronic supplementary material The online version of this article (doi:10.1186/s40249-016-0162-5) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Celsus Sente
- Department of Wildlife and Aquatic Animal Resources (WAAR), School of Veterinary Medicine and Animal Resources (SVAR), College of Veterinary Medicine, Animal Resources and Biosecurity (COVAB), Makerere University, P.O.Box 7062, Kampala, Uganda.
| | - Joseph Erume
- Department of Biomolecular Resources and Biolab Sciences, School of Bio-security, Biotechnical and Laboratory Sciences (SBLS), College of Veterinary Medicine, Animal Resources and Biosecurity (COVAB), Makerere University, P.O.Box 7062, Kampala, Uganda
| | - Irene Naigaga
- Department of Wildlife and Aquatic Animal Resources (WAAR), School of Veterinary Medicine and Animal Resources (SVAR), College of Veterinary Medicine, Animal Resources and Biosecurity (COVAB), Makerere University, P.O.Box 7062, Kampala, Uganda
| | - Julius Mulindwa
- Department of Biomolecular Resources and Biolab Sciences, School of Bio-security, Biotechnical and Laboratory Sciences (SBLS), College of Veterinary Medicine, Animal Resources and Biosecurity (COVAB), Makerere University, P.O.Box 7062, Kampala, Uganda.,Department of Biochemistry and Sports Science (BSS), College of Natural Sciences (CONAS), Makerere University, P.O. Box 7062, Kampala, Uganda
| | - Sylvester Ochwo
- Department of Biomolecular Resources and Biolab Sciences, School of Bio-security, Biotechnical and Laboratory Sciences (SBLS), College of Veterinary Medicine, Animal Resources and Biosecurity (COVAB), Makerere University, P.O.Box 7062, Kampala, Uganda
| | - Phillip Kimuda Magambo
- Department of Biomolecular Resources and Biolab Sciences, School of Bio-security, Biotechnical and Laboratory Sciences (SBLS), College of Veterinary Medicine, Animal Resources and Biosecurity (COVAB), Makerere University, P.O.Box 7062, Kampala, Uganda
| | - Benigna Gabriela Namara
- Medical Research Council (MRC)/Uganda Virus Research Institute (UVRI), Research Unit on AIDS, P.O.Box 49, Entebbe, Uganda
| | - Charles Drago Kato
- Department of Biomolecular Resources and Biolab Sciences, School of Bio-security, Biotechnical and Laboratory Sciences (SBLS), College of Veterinary Medicine, Animal Resources and Biosecurity (COVAB), Makerere University, P.O.Box 7062, Kampala, Uganda
| | - George Sebyatika
- Department of Biomolecular Resources and Biolab Sciences, School of Bio-security, Biotechnical and Laboratory Sciences (SBLS), College of Veterinary Medicine, Animal Resources and Biosecurity (COVAB), Makerere University, P.O.Box 7062, Kampala, Uganda.,Department of Molecular Biology, Vrije Universiteit, Pleinlaan 21050, Brussels, Belgium
| | - Kevin Muwonge
- Department of Biomolecular Resources and Biolab Sciences, School of Bio-security, Biotechnical and Laboratory Sciences (SBLS), College of Veterinary Medicine, Animal Resources and Biosecurity (COVAB), Makerere University, P.O.Box 7062, Kampala, Uganda.,Department of Molecular Biology, Vrije Universiteit, Pleinlaan 21050, Brussels, Belgium
| | - Michael Ocaido
- Department of Wildlife and Aquatic Animal Resources (WAAR), School of Veterinary Medicine and Animal Resources (SVAR), College of Veterinary Medicine, Animal Resources and Biosecurity (COVAB), Makerere University, P.O.Box 7062, Kampala, Uganda
| |
Collapse
|
11
|
Kirschner AK. Determination of viable legionellae in engineered water systems: Do we find what we are looking for? WATER RESEARCH 2016; 93:276-288. [PMID: 26928563 PMCID: PMC4913838 DOI: 10.1016/j.watres.2016.02.016] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2015] [Revised: 02/06/2016] [Accepted: 02/09/2016] [Indexed: 05/06/2023]
Abstract
In developed countries, legionellae are one of the most important water-based bacterial pathogens caused by management failure of engineered water systems. For routine surveillance of legionellae in engineered water systems and outbreak investigations, cultivation-based standard techniques are currently applied. However, in many cases culture-negative results are obtained despite the presence of viable legionellae, and clinical cases of legionellosis cannot be traced back to their respective contaminated water source. Among the various explanations for these discrepancies, the presence of viable but non-culturable (VBNC) Legionella cells has received increased attention in recent discussions and scientific literature. Alternative culture-independent methods to detect and quantify legionellae have been proposed in order to complement or even substitute the culture method in the future. Such methods should detect VBNC Legionella cells and provide a more comprehensive picture of the presence of legionellae in engineered water systems. However, it is still unclear whether and to what extent these VBNC legionellae are hazardous to human health. Current risk assessment models to predict the risk of legionellosis from Legionella concentrations in the investigated water systems contain many uncertainties and are mainly based on culture-based enumeration. If VBNC legionellae should be considered in future standard analysis, quantitative risk assessment models including VBNC legionellae must be proven to result in better estimates of human health risk than models based on cultivation alone. This review critically evaluates current methods to determine legionellae in the VBNC state, their potential to complement the standard culture-based method in the near future, and summarizes current knowledge on the threat that VBNC legionellae may pose to human health.
Collapse
Affiliation(s)
- Alexander K.T. Kirschner
- Medical University Vienna, Institute for Hygiene and Applied Immunology, Water Hygiene, Kinderspitalgasse 15, A-1090 Vienna, Austria
- Interuniversity Cooperation Centre for Water & Health, Austria
- Medical University Vienna, Institute for Hygiene and Applied Immunology, Water Hygiene Kinderspitalgasse 16, A-1090 Vienna, Austria . URL: http://www.waterandhealth.at
| |
Collapse
|
12
|
Blanky M, Rodríguez-Martínez S, Halpern M, Friedler E. Legionella pneumophila: From potable water to treated greywater; quantification and removal during treatment. THE SCIENCE OF THE TOTAL ENVIRONMENT 2015; 533:557-565. [PMID: 26188406 DOI: 10.1016/j.scitotenv.2015.06.121] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2015] [Revised: 06/19/2015] [Accepted: 06/28/2015] [Indexed: 06/04/2023]
Abstract
Greywater is an alternative water source that can help alleviate stress on depleted water resources. The main options for greywater reuse are toilet flushing and garden irrigation, both producing aerosols. For that reason transmission of inhalable pathogens like Legionella present a potential risk. To improve the understanding about Legionella in greywater, we traced the pathogen seasonally from the potable water system to the final steps of the greywater treatment in four houses in northern Israel. Physicochemical and microbiological parameters were analyzed in order to assess background greywater quality and to establish possible associations with Legionella. The mean concentrations of Legionella pneumophila isolated from the potable water system were 6.4×10(2) and 5.9×10(3) cfu/l in cold and hot water respectively. By amending the ISO protocol for Legionella isolation from drinking water, we succeeded in quantifying Legionella in greywater. The mean Legionella concentrations that were found in raw, treated and treated chlorinated greywater were 1.2×10(5), 2.4×10(4) and 5.7×10(3) cfu/l respectively. While Legionella counts in potable water presented a seasonal pattern with high concentrations in summer, its counts in greywater presented an almost inversed pattern. Greywater treatment resulted in 95% decrease in Legionella counts. No significant difference was found between Legionella concentrations in potable water and the treated chlorinated greywater. These findings indicate that regarding Legionella, reusing treated chlorinated greywater would exhibit a risk that is very similar to the risk associated with using potable water for the same non-potable uses.
Collapse
Affiliation(s)
- Marina Blanky
- Faculty of Civil and Environmental Engineering, Technion, Haifa, Israel
| | - Sara Rodríguez-Martínez
- Department of Evolutionary and Environmental Biology, Faculty of Natural Sciences, University of Haifa, Haifa, Israel.
| | - Malka Halpern
- Department of Evolutionary and Environmental Biology, Faculty of Natural Sciences, University of Haifa, Haifa, Israel; Department of Biology and Environment, Faculty of Natural Sciences, University of Haifa, Oranim, Tivon, Israel
| | - Eran Friedler
- Faculty of Civil and Environmental Engineering, Technion, Haifa, Israel
| |
Collapse
|
13
|
Jjemba PK, Johnson W, Bukhari Z, LeChevallier MW. Occurrence and Control of Legionella in Recycled Water Systems. Pathogens 2015; 4:470-502. [PMID: 26140674 PMCID: PMC4584268 DOI: 10.3390/pathogens4030470] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2015] [Accepted: 06/24/2015] [Indexed: 01/11/2023] Open
Abstract
Legionella pneumophila is on the United States Environmental Protection Agency (USEPA) Candidate Contaminant list (CCL) as an important pathogen. It is commonly encountered in recycled water and is typically associated with amoeba, notably Naegleria fowleri (also on the CCL) and Acanthamoeba sp. No legionellosis outbreak has been linked to recycled water and it is important for the industry to proactively keep things that way. A review was conducted examine the occurrence of Legionella and its protozoa symbionts in recycled water with the aim of developing a risk management strategy. The review considered the intricate ecological relationships between Legionella and protozoa, methods for detecting both symbionts, and the efficacy of various disinfectants.
Collapse
Affiliation(s)
- Patrick K Jjemba
- American Water Research Laboratory, 213 Carriage Lane, Delran, NJ 08075, USA.
| | - William Johnson
- American Water Research Laboratory, 213 Carriage Lane, Delran, NJ 08075, USA.
| | - Zia Bukhari
- American Water, 1025 Laurel Oak Road, Voorhees, NJ 08043, USA.
| | | |
Collapse
|