1
|
Kouamé DR, Aboli RA, Kabran M, Adiko AC, Coulibaly M, Dembele B, Inwoley A. Validation of dried blood spots samples for the screening of hepatitis B virus surface by enzyme immunoassay method. J Immunol Methods 2023; 513:113412. [PMID: 36586510 DOI: 10.1016/j.jim.2022.113412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 12/26/2022] [Accepted: 12/27/2022] [Indexed: 12/29/2022]
Abstract
Dried Blood Spots (DBS) are blood collection carriers that facilitate the storage and transport of samples. Used for quality control during sero-epidemiological investigations, DBS eluate are not the conventional specimen indicated by manufacturers for enzyme immunoassay method (EIA) for hepatitis B virus surface (HBs antigen). The aim of our study was to evaluate DBS eluates used as a matrix for EIA of HBs antigen in a reference laboratory. This study took place from August 2016 to November 2017 at the Centre for Diagnosis and Research on AIDS and other infectious diseases (CeDReS) in Abidjan, Côte d'Ivoire. We used a panel of 149 whole blood samples from blood donors. The DBS performed with these samples were analyzed after elution with the HBsAg (version ULTRA) ELISA, Dia.Pro Diagnostic Bioprobes S.R.L., Sesto San Giovanni, Italy. The technical performance (sensitivity and specificity and kappa coefficient) of the test performed on DBS was determined for different ratios (optical density/threshold value) compared to the results obtained on the plasma used as reference. We obtained a sensitivity of 100% with DBS for all ratios. The specificity increased according to the ratio of optical density of the individual EIA reaction to the threshold value, with 6.09%, 47.0%, and 83.0%, respectively, for ratios of 1.0, 3.0, and 5.0. Best performance was observed at ratio of 10.0 with a sensitivity and specificity of 100%. In conclusion, DBS eluate can be used for the diagnosis of viral hepatitis B and would be useful for conducting sero-epidemiological investigations. However, ratio giving best performance must be determined for each enzyme immunoassay method kits.
Collapse
Affiliation(s)
- Denis Rodrigue Kouamé
- Immunology Unit, UFR Pharmaceuticals and Biological Sciences, Félix Houphouët-Boigny University, BPV 34 Abidjan 01, Abidjan, Ivory Coast
| | - Roseline Affi Aboli
- Immunology Unit, UFR Pharmaceuticals and Biological Sciences, Félix Houphouët-Boigny University, BPV 34 Abidjan 01, Abidjan, Ivory Coast; Research and Diagnosis Center for AIDS and other infectious diseases (CeDReS), CHU (University Hospital) of Treichville, BP V3 Abidjan 01, Abidjan, Ivory Coast
| | - Mathieu Kabran
- Immunology Unit, UFR Pharmaceuticals and Biological Sciences, Félix Houphouët-Boigny University, BPV 34 Abidjan 01, Abidjan, Ivory Coast; Research and Diagnosis Center for AIDS and other infectious diseases (CeDReS), CHU (University Hospital) of Treichville, BP V3 Abidjan 01, Abidjan, Ivory Coast
| | - Aimé Cézaire Adiko
- Immunology Unit, UFR Pharmaceuticals and Biological Sciences, Félix Houphouët-Boigny University, BPV 34 Abidjan 01, Abidjan, Ivory Coast; Research and Diagnosis Center for AIDS and other infectious diseases (CeDReS), CHU (University Hospital) of Treichville, BP V3 Abidjan 01, Abidjan, Ivory Coast
| | - Mabarakissa Coulibaly
- Immunology Unit, UFR Pharmaceuticals and Biological Sciences, Félix Houphouët-Boigny University, BPV 34 Abidjan 01, Abidjan, Ivory Coast
| | - Bamory Dembele
- Immunology Unit, UFR Pharmaceuticals and Biological Sciences, Félix Houphouët-Boigny University, BPV 34 Abidjan 01, Abidjan, Ivory Coast; Laboratory of NBTS (National Blood Transfusion Center), BP V15 Abidjan 01, Ivory Coast.
| | - Andre Inwoley
- Immunology Unit, UFR Pharmaceuticals and Biological Sciences, Félix Houphouët-Boigny University, BPV 34 Abidjan 01, Abidjan, Ivory Coast; Research and Diagnosis Center for AIDS and other infectious diseases (CeDReS), CHU (University Hospital) of Treichville, BP V3 Abidjan 01, Abidjan, Ivory Coast
| |
Collapse
|
2
|
Application of a Sanger-Based External Quality Assurance Strategy for the Transition of HIV-1 Drug Resistance Assays to Next Generation Sequencing. Viruses 2020; 12:v12121456. [PMID: 33348705 PMCID: PMC7766986 DOI: 10.3390/v12121456] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Accepted: 12/15/2020] [Indexed: 01/05/2023] Open
Abstract
The National Institute of Allergy and Infectious Diseases (NIAID) Virology Quality Assurance (VQA) established a robust proficiency testing program for Sanger sequencing (SS)-based HIV-1 drug resistance (HIVDR) testing in 2001. While many of the lessons learned during the development of such programs may also apply to next generation sequencing (NGS)-based HIVDR assays, challenges remain for the ongoing evaluation of NGS-based testing. These challenges include a proper assessment of assay accuracy and the reproducibility of low abundance variant detection, intra- and inter-assay performance comparisons among laboratories using lab-defined tests, and different data analysis pipelines designed for NGS. In collaboration with the World Health Organization (WHO) Global HIVDR Laboratory Network and the Public Health Agency of Canada, the Rush VQA program distributed archived proficiency testing panels to ten laboratories to evaluate internally developed NGS assays. Consensus FASTA files were submitted using 5%, 10%, and 20% variant detection thresholds, and scored based on the same criteria used for SS. This small study showed that the SS External Quality Assurance (EQA) approach can be used as a transitional strategy for using NGS to generate SS-like data and for ongoing performance while using NGS data from the same quality control materials to further evaluate NGS assay performance.
Collapse
|
3
|
Protti M, Mandrioli R, Mercolini L. Quantitative microsampling for bioanalytical applications related to the SARS-CoV-2 pandemic: Usefulness, benefits and pitfalls. J Pharm Biomed Anal 2020; 191:113597. [PMID: 32927419 PMCID: PMC7456588 DOI: 10.1016/j.jpba.2020.113597] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 08/23/2020] [Accepted: 08/25/2020] [Indexed: 12/20/2022]
Abstract
The multiple pathological effects of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection, and its total novelty, mean that currently a lot of diagnostic and therapeutic tools, established and tentative alike, are needed to treat patients in a timely, effective way. In order to make these tools more reliable, faster and more feasible, biological fluid microsampling techniques could provide many advantages. In this review, the most important microsampling techniques are considered (dried matrix spots, volumetric absorptive microsampling, microfluidics and capillary microsampling, solid phase microextraction) and their respective advantages and disadvantages laid out. Moreover, currently available microsampling applications of interest for SARS-CoV-2 therapy are described, in order to make them as much widely known as possible, hopefully providing useful information to researchers and clinicians alike.
Collapse
Affiliation(s)
- Michele Protti
- Research Group of Pharmaco-Toxicological Analysis (PTA Lab), Department of Pharmacy and Biotechnology (FaBiT), Alma Mater Studiorum - University of Bologna, Via Belmeloro 6, 40126 Bologna, Italy
| | - Roberto Mandrioli
- Department for Life Quality Studies, Alma Mater Studiorum - University of Bologna, Corso d'Augusto 237, 47921 Rimini, Italy
| | - Laura Mercolini
- Research Group of Pharmaco-Toxicological Analysis (PTA Lab), Department of Pharmacy and Biotechnology (FaBiT), Alma Mater Studiorum - University of Bologna, Via Belmeloro 6, 40126 Bologna, Italy.
| |
Collapse
|
4
|
Sok P, Lupo PJ, Richard MA, Rabin KR, Ehli EA, Kallsen NA, Davies GE, Scheurer ME, Brown AL. Utilization of archived neonatal dried blood spots for genome-wide genotyping. PLoS One 2020; 15:e0229352. [PMID: 32084225 PMCID: PMC7034898 DOI: 10.1371/journal.pone.0229352] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Accepted: 02/04/2020] [Indexed: 01/14/2023] Open
Abstract
Introduction Heel pricks are performed on newborns for diagnostic screenings of various pre-symptomatic metabolic and genetic diseases. Excess blood is spotted on Guthrie cards and archived by many states in biobanks for follow-up diagnoses and public health research. However, storage environment may vary across biobanks and across time within biobanks. With increased applications of DNA extracted from spots for genetic studies, identifying factors associated with genotyping success is critical to maximize DNA quality for future studies. Method We evaluated 399 blood spots, which were part of a genome-wide association study of childhood leukemia risk in children with Down syndrome, archived at the Michigan Neonatal Biobank between 1992 and 2008. High quality DNA was defined as having post-quality control call rate ≥ 99.0% based on the Illumina GenomeStudio 2.0 GenCall algorithm after processing the samples on the Illumina Infinium Global Screening Array. Bivariate analyses and multivariable logistic regression models were applied to evaluate effects of storage environment and storage duration on DNA genotyping quality. Results Both storage environment and duration were associated with sample genotyping call rates (p-values < 0.001). Sample call rates were associated with storage duration independent of storage environment (p-trend = 0.006 for DBS archived in an uncontrolled environment and p-trend = 0.002 in a controlled environment). However, 95% of the total sample had high genotyping quality with a call rate ≥ 95.0%, a standard threshold for acceptable sample quality in many genetic studies. Conclusion Blood spot DNA quality was lower in samples archived in uncontrolled storage environments and for samples archived for longer durations. Still, regardless of storage environment or duration, neonatal biobanks including the Michigan Neonatal Biobanks can provide access to large collections of spots with DNA quality acceptable for most genotyping studies.
Collapse
Affiliation(s)
- Pagna Sok
- Department of Pediatrics, Hematology-Oncology Section, Baylor College of Medicine, Houston, Texas, United States of America
| | - Philip J. Lupo
- Department of Pediatrics, Hematology-Oncology Section, Baylor College of Medicine, Houston, Texas, United States of America
| | - Melissa A. Richard
- Department of Pediatrics, Hematology-Oncology Section, Baylor College of Medicine, Houston, Texas, United States of America
| | - Karen R. Rabin
- Department of Pediatrics, Hematology-Oncology Section, Baylor College of Medicine, Houston, Texas, United States of America
| | - Erik A. Ehli
- Avera Institute for Human Genetics, Sioux Falls, South Dakota, United States of America
| | - Noah A. Kallsen
- Avera Institute for Human Genetics, Sioux Falls, South Dakota, United States of America
| | - Gareth E. Davies
- Avera Institute for Human Genetics, Sioux Falls, South Dakota, United States of America
| | - Michael E. Scheurer
- Department of Pediatrics, Hematology-Oncology Section, Baylor College of Medicine, Houston, Texas, United States of America
| | - Austin L. Brown
- Department of Pediatrics, Hematology-Oncology Section, Baylor College of Medicine, Houston, Texas, United States of America
- * E-mail:
| |
Collapse
|
5
|
Stability of Human Immunodeficiency Virus Serological Markers in Samples Collected as HemaSpot and Whatman 903 Dried Blood Spots. J Clin Microbiol 2018; 56:JCM.00933-18. [PMID: 30045869 DOI: 10.1128/jcm.00933-18] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2018] [Accepted: 07/13/2018] [Indexed: 11/20/2022] Open
Abstract
Dried blood spots (DBS) are frequently used in clinical testing for biosurveillance, infectious disease and confirmatory testing, and clinical trials, particularly for populations in remote areas. The HemaSpot-HF blood collection device (HS) provides an alternative format to the Whatman 903 cards (903) to simplify sample collection and processing. In this study, the performance of the HS was compared to that of the 903 using previously characterized clinical specimens and HIV seroconversion panels known to exhibit markers of early human immunodeficiency virus (HIV) infection. HS and 903 samples were prepared and tested by Bio-Rad GS HIV Combo Ag/Ab enzyme immunoassay (EIA), GS HIV-1/-2 Plus O EIA, GS HIV-1 Western blot, and HIV-1 Geenius assays. Both HS and 903 performed well for up to 6 months at room temperature, but a marked loss of Western blot and low titer antibody signals from early infection samples was observed in samples stored for 180 days at elevated (37 to 45°C) temperatures and high humidity (95%). HemaSpot samples placed in sealed bags with additional desiccant were protected from degradation and showed improved signal recovery relative to that of the 903. HS was easier to use than the 903 and showed higher sensitivity and reproducibility for early infection samples and improved stability.
Collapse
|
6
|
Jennings C, Harty B, Scianna SR, Granger S, Couzens A, Zaccaro D, Bremer JW. The stability of HIV-1 nucleic acid in whole blood and improved detection of HIV-1 in alternative specimen types when compared to Dried Blood Spot (DBS) specimens. J Virol Methods 2018; 261:91-97. [PMID: 30125614 DOI: 10.1016/j.jviromet.2018.08.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Revised: 08/07/2018] [Accepted: 08/08/2018] [Indexed: 11/28/2022]
Abstract
BACKGROUND Commercially-available kits for HIV-1 detection include instructions for detecting HIV-1 in plasma and DBS, but don't support other specimen types. OBJECTIVES Show quantitative stability of HIV-1 total nucleic acid (TNA) in blood and improved HIV-1 detection in alternative specimen types. STUDY DESIGN Whole blood and DBS specimens, tested as part of an external quality assurance program for qualitative HIV-1 detection, were used to evaluated error rates (false negative [FN], false positive [FP] and indeterminant [IND] results) across assays (internally developed [IH], Roche Amplicor [RA], and Roche TaqMan Qual [TQ]) and specimen types (frozen whole blood [BLD], DBS and cell pellets [PEL]). A modified Roche TaqMan HIV-1 assay was used to quantify HIV-1 TNA. RESULTS Significantly higher error rates were noted in DBS across all of the assays (4% vs. 0% for DBS and PEL, IH, p = 0.005; 4% vs. 0.1% for DBS and PEL, RA, p < 0.001; 10% vs. 1% for DBS and PEL or BLD, TQ, p < 0.001). HIV TNA concentration is stable in BLD (day 1 vs. day 10, p = 0.39) and higher than DBS (p < 0.001). CONCLUSIONS Transporting refrigerated whole blood for centralized processing into alternative specimen types will improve the sensitivitiy of HIV-1 detection in samples with low virus loads.
Collapse
Affiliation(s)
- Cheryl Jennings
- Rush Medical College, Department of Microbial Pathogens and Immunity, Chicago, IL, USA.
| | - Brian Harty
- New England Research Institute, Boston, MA, USA
| | - Salvatore R Scianna
- Rush Medical College, Department of Microbial Pathogens and Immunity, Chicago, IL, USA
| | | | - Amy Couzens
- RTI International, Research Triangle Park, NC, USA
| | | | - James W Bremer
- Rush Medical College, Department of Microbial Pathogens and Immunity, Chicago, IL, USA
| |
Collapse
|
7
|
Lim MD. Dried Blood Spots for Global Health Diagnostics and Surveillance: Opportunities and Challenges. Am J Trop Med Hyg 2018; 99:256-265. [PMID: 29968557 PMCID: PMC6090344 DOI: 10.4269/ajtmh.17-0889] [Citation(s) in RCA: 106] [Impact Index Per Article: 17.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2017] [Accepted: 05/02/2018] [Indexed: 12/28/2022] Open
Abstract
There is increasing interest in using dried blood spot (DBS) cards to extend the reach of global health and disease surveillance programs to hard-to-reach populations. Conceptually, DBS offers a cost-effective solution for multiple use cases by simplifying logistics for collecting, preserving, and transporting blood specimens in settings with minimal infrastructure. This review describes methods to determine both the reliability of DBS-based bioanalysis for a defined use case and the optimal conditions that minimize pre-analytical sources of data variability. Examples by the newborn screening, drug development, and global health communities are provided in this review of published literature. Sources of variability are linked in most cases, emphasizing the importance of field-to-laboratory standard operating procedures that are evidence based and consider both stability and efficiency of recovery for a specified analyte in defining the type of DBS card, accessories, handling procedures, and storage conditions. Also included in this review are reports where DBS was determined to not be feasible because of technology limitations or physiological properties of a targeted analyte.
Collapse
Affiliation(s)
- Mark D. Lim
- Global Health Division, Bill & Melinda Gates Foundation, Seattle, Washington
| |
Collapse
|
8
|
Zaniello B, Huang ML, Cheng A, Selke S, Wald A, Jerome KR, Magaret AS. Consistent viral DNA quantification after prolonged storage at ambient temperature. J Virol Methods 2015; 228:91-4. [PMID: 26611228 DOI: 10.1016/j.jviromet.2015.11.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2015] [Revised: 11/12/2015] [Accepted: 11/16/2015] [Indexed: 10/22/2022]
Abstract
Long-term storage of biological specimens at low temperatures is costly and impractical in resource limited settings, where the disease burden of chronic viral infections is highest, and the need for research greatest. We examined the necessity of cold storage by comparing the quantity of HHV-8 DNA recovered from swab samples before and after 9-11 months of storage at temperatures of -20 °C, 4 °C and 37 °C. Quantitative levels of HHV-8 DNA remained consistent for laboratory or mucosal swab samples regardless of storage temperature. Freezer storage is determined to be not necessary for mucosal samples destined for HHV-8 DNA quantification.
Collapse
Affiliation(s)
| | - Meei-Li Huang
- Vaccine and Infectious Disease Division, Fred Hutchinson Cancer Research Center, United States; Department of Laboratory Medicine, University of Washington, United States
| | - Anqi Cheng
- Department of Biostatistics, University of Washington, United States
| | - Stacy Selke
- Department of Laboratory Medicine, University of Washington, United States
| | - Anna Wald
- Department of Medicine, University of Washington, United States; Vaccine and Infectious Disease Division, Fred Hutchinson Cancer Research Center, United States; Department of Laboratory Medicine, University of Washington, United States; Department of Epidemiology, University of Washington, United States
| | - Keith R Jerome
- Vaccine and Infectious Disease Division, Fred Hutchinson Cancer Research Center, United States; Department of Laboratory Medicine, University of Washington, United States
| | - Amalia S Magaret
- Vaccine and Infectious Disease Division, Fred Hutchinson Cancer Research Center, United States; Department of Laboratory Medicine, University of Washington, United States; Department of Biostatistics, University of Washington, United States.
| |
Collapse
|
9
|
Seu L, Mwape I, Guffey MB. Single genome amplification of proviral HIV-1 DNA from dried blood spot specimens collected during early infant screening programs in Lusaka, Zambia. J Virol Methods 2014; 203:97-101. [PMID: 24667303 PMCID: PMC4024391 DOI: 10.1016/j.jviromet.2014.03.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2014] [Revised: 02/28/2014] [Accepted: 03/04/2014] [Indexed: 01/28/2023]
Abstract
The ability to evaluate individual HIV-1 virions from the quasispecies of vertically infected infants was evaluated in a field setting at the Centre for Infectious Disease Research in Zambia. Infant heel-prick blood specimens were spotted onto dried blood spot (DBS) filter paper cards at government health clinics. Nucleic acid was extracted and used as a template for HIV-1 proviral DNA detection by a commercial Amplicor HIV-1 PCR test (Roche, version 1.5). On samples that tested positive by commercial diagnostic assay, amplification of DNA was performed using an in-house assay of the 5' and 3' region of the HIV-1 genome. Additionally, fragments covering 1200 nucleotides within pol (full length protease and partial reverse transcriptase) and 1400 nucleotides within env (variable 1-variable 5 region) were further analyzed by single genome amplification (SGA). In summary, we have demonstrated an in-house assay for amplifying the 5' and 3' proviral HIV-1 DNA as well as pol and env proviral DNA fragments from DBS cards collected and analyzed entirely in Zambia. In conclusion, this study shows the feasibility of utilizing DBS cards to amplify the whole proviral HIV-1 genome as well as perform SGA on key HIV-1 genes.
Collapse
Affiliation(s)
- Lillian Seu
- Centre for Infectious Disease Research Zambia, 5032 Great North Road, P.O. Box 34681, Lusaka, Zambia; University of Alabama at Birmingham, Division of Infectious Diseases, 1900 University Boulevard, THT 215E, Birmingham, AL 35294, United States.
| | - Innocent Mwape
- University of Alabama at Birmingham, Division of Infectious Diseases, 1900 University Boulevard, THT 215E, Birmingham, AL 35294, United States.
| | - M Bradford Guffey
- Centre for Infectious Disease Research Zambia, 5032 Great North Road, P.O. Box 34681, Lusaka, Zambia; University of Alabama at Birmingham, Division of Infectious Diseases, 1900 University Boulevard, THT 215E, Birmingham, AL 35294, United States.
| |
Collapse
|
10
|
Merati TP, Ryan CE, Spelmen T, Wirawan DN, Bakta IM, Otto B, Oelrichs RB, Crowe SM. CRF01_AE dominates the HIV-1 epidemic in Indonesia. Sex Health 2013; 9:414-21. [PMID: 22958472 DOI: 10.1071/sh11121] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2011] [Accepted: 04/05/2012] [Indexed: 11/23/2022]
Abstract
BACKGROUND The HIV epidemic in Indonesia remains concentrated in vulnerable populations, namely injecting drug users (IDUs), commercial sex workers (CSWs) and men who have sex with men (MSM). We aimed to determine the HIV-1 subtypes present in Indonesia and to establish the extent of the viral overlap between individuals with different risk factors. METHODS Venous blood samples were collected from HIV-positive individuals primarily from sexually transmissible infection clinics and drug rehabilitation centres in Bali and Jakarta, and applied to filter paper. A polymerase chain reaction-based assay designed to amplify a 330-bp region of the HIV-1 envelope was used to determine HIV-1 subtype result and to perform phylogenetic analysis. RESULTS Of the 175 individuals recruited to the study, a subtype result was obtained for 108 (62%). Four subtypes were found to exist in the population, CRF01_AE (n=96, 88.9%), B (n=10, 9.3%), C (n=1, 0.9%) and G (n=1, 0.9%). Of these 108 individuals, 65 (60%) were IDUs, and the remaining 40% were CSWs, MSM, transgender individuals, people with multiple sexual partners or those with no obvious risk factor. CRF01_AE was found to be more common among IDUs with 100% of individuals infected with this subtype. Subtype B was more common among MSM and CSWs (P=<0.001). Phylogenetic analysis revealed a lack of viral segregation between risk groups. CONCLUSIONS In Indonesia, CRF01_AE continues to dominate the HIV epidemic, although HIV subtype B is responsible for a significant number of sexually acquired infections.
Collapse
|
11
|
Antiviral resistance and correlates of virologic failure in the first cohort of HIV-infected children gaining access to structured antiretroviral therapy in Lima, Peru: a cross-sectional analysis. BMC Infect Dis 2013; 13:1. [PMID: 23280237 PMCID: PMC3782360 DOI: 10.1186/1471-2334-13-1] [Citation(s) in RCA: 71] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2012] [Accepted: 12/21/2012] [Indexed: 01/30/2023] Open
Abstract
BACKGROUND The impact of extended use of ART in developing countries has been enormous. A thorough understanding of all factors contributing to the success of antiretroviral therapy is required. The current study aims to investigate the value of cross-sectional drug resistance monitoring using DNA and RNA oligonucleotide ligation assays (OLA) in treatment cohorts in low-resource settings. The study was conducted in the first cohort of children gaining access to structured ART in Peru. METHODS Between 2002-5, 46 eligible children started the standard regimen of AZT, 3TC and NFV Patients had a median age of 5.6 years (range: 0.7-14y), a median viral load of 1.7·105 RNA/ml (range: 2.1·10(3) - 1.2·10(6)), and a median CD4-count of 232 cells/μL (range: 1-1591). Of these, 20 patients were classified as CDC clinical category C and 31/46 as CDC immune category 3. At the time of cross-sectional analysis in 2005, adherence questionnaires were administered. DNA OLAs and RNA OLAs were performed from frozen PBMC and plasma, RNA genotyping from dried blood spots. RESULTS During the first year of ART, 44% of children experienced virologic failure, with an additional 9% failing by the end of the second year. Virologic failure was significantly associated with the number of resistance mutations detected by DNA-OLA (p < 0.001) during cross-sectional analysis, but also with low immunologic CDC-scores at baseline (p < 0.001). Children who had been exposed to unsupervised short-term antiretrovirals before starting structured ART showed significantly higher numbers of resistance mutations by DNA-OLA (p = 0.01). Detection of M184V (3TC resistance) by RNA-OLA and DNA-OLA demonstrated a sensitivity of 0.93 and 0.86 and specificity of 0.67 and 0.7, respectively, for the identification of virologic failure. The RT mutations N88D and L90M (NFV resistance) detected by DNA-OLA correlated with virologic failure, whereas mutations at RT position 215 (AZT resistance) were not associated with virologic failure. CONCLUSIONS Advanced immunosuppression at baseline and previous exposures to unsupervised brief cycles of ART significantly impaired treatment outcomes at a time when structured ART was finally introduced in his cohort. Brief maternal exposures to with AZT +/- NVP for the prevention of mother-to-child transmission did not affect treatment outcomes in this group of children. DNA-OLA from frozen PBMC provided a highly specific tool to detect archived drug resistance. RNA consensus genotyping from dried blood spots and RNA-OLA from plasma consistently detected drug resistance mutations, but merely in association with virologic failure.
Collapse
|
12
|
Lang PO, Govind S, Dramé M, Aspinall R. Comparison of manual and automated DNA purification for measuring TREC in dried blood spot (DBS) samples with qPCR. J Immunol Methods 2012; 384:118-27. [DOI: 10.1016/j.jim.2012.07.016] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2012] [Revised: 07/24/2012] [Accepted: 07/24/2012] [Indexed: 12/16/2022]
|
13
|
Masciotra S, Khamadi S, Bilé E, Puren A, Fonjungo P, Nguyen S, Girma M, Downing R, Ramos A, Subbarao S, Ellenberger D. Evaluation of blood collection filter papers for HIV-1 DNA PCR. J Clin Virol 2012; 55:101-6. [DOI: 10.1016/j.jcv.2012.06.010] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2012] [Revised: 06/14/2012] [Accepted: 06/15/2012] [Indexed: 10/28/2022]
|
14
|
False-negative post-18-month confirmatory HIV tests in HIV DNA PCR-positive children: a retrospective analysis. AIDS 2012; 26:1927-34. [PMID: 22739392 DOI: 10.1097/qad.0b013e32835705bf] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The WHO guidelines for children less than 18 months old diagnosed with HIV based on presumptive clinical diagnosis or one virologic test recommend confirmatory HIV antibody testing after 18 months of age. This study describes post-18-month HIV test results following this WHO-recommended confirmatory testing strategy. DESIGN Case series and retrospective review of routine program data. METHODS Children enrolled at the Baylor Children's Clinical Center of Excellence, a pediatric and family HIV clinic in Maseru, Lesotho from December 2005 through January 2009 with a positive HIV DNA PCR at less than 18 months of age and HIV rapid test results after 18 months of age were included. Post-18-month confirmatory HIV test results are described. Factors associated with non-positive confirmatory rapid tests were determined using binary logistic regression. RESULTS Of the 109 children meeting inclusion criteria, 22 (20.2%) had negative and 27 (24.8%) discordant confirmatory rapid tests. Forty-six of these 49 were on antiretroviral therapy (ART). Among these 49, 11 of 24 post-18-month HIV DNA PCRs were negative, whereas nine of 10 post-18-month HIV ELISAs were positive; 29 were definitively and 17 probably HIV-infected, two were uninfected, and one had undetermined status. Only age less than 9 months at ART initiation (odds ratio 4.25, P = 0.002) was associated with non-positive rapid tests. CONCLUSION False-negative post-18-month confirmatory rapid tests and HIV DNA PCRs in children on ART are common, associated with early ART initiation, and may lead to inappropriate ART discontinuation and discharge from care of truly HIV-infected children.
Collapse
|
15
|
Montgomery ET, van der Pol B, van der Straten A, Ramjee G, de Bruyn G, Chipato T, Blanchard K, Padian NS. Discrepancies in diagnosis of incident HIV infection between antibody- and DNA-based tests in a phase III prevention trial in southern Africa. Int J STD AIDS 2012; 23:649-52. [DOI: 10.1258/ijsa.2009.009124] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Dried blood spots (DBS) are widely used to test for HIV in a variety of research and service delivery settings; however, uniform guidelines regarding collection, storage and DNA extraction processes have neither been developed nor evaluated. Previously published reports suggested DBS may be stored at room temperature for up to 60 days, and intensive stability tests have shown that DBS can withstand high temperatures, humidity and freeze–thawing. During the implementation of a large randomized controlled trial (RCT) in southern Africa, with HIV acquisition as the primary endpoint, we observed 65 instances when DBS samples collected from the same day as a positive HIV antibody test yielded negative DNA polymerase chain reaction (PCR) results. The source of this discrepancy may have been due to inadequate specimen volume, filter paper or DNA extraction procedures, but were most likely due to storage conditions that have been reported as acceptable in other settings.
Collapse
Affiliation(s)
- E T Montgomery
- Women's Global Health Imperative, RTI International, San Francisco Project Office, San Francisco, CA, USA
| | - B van der Pol
- Indiana University School of Medicine, Infectious Disease Laboratory, Indianapolis, IN
| | - A van der Straten
- Women's Global Health Imperative, RTI International, San Francisco Project Office, San Francisco, CA, USA
- Center for AIDS Prevention Studies, Department of Medicine, University of California San Francisco, San Francisco, CA, USA
| | - G Ramjee
- Medical Research Council, Kwazulu-Natal
| | - G de Bruyn
- Perinatal HIV Research Unit, Johannesburg, South Africa
| | - T Chipato
- University of Zimbabwe-University of California San Francisco Research Collaborative Programme in Women's Health, Harare, Zimbabwe
| | - K Blanchard
- Ibis Reproductive Health, Cambridge, MA, USA
- Ibis Reproductive Health, Johannesburg, South Africa
| | - N S Padian
- Women's Global Health Imperative, RTI International, San Francisco Project Office, San Francisco, CA, USA
| | | |
Collapse
|
16
|
[Dried blood spots for monitoring HIV infection in Public Health Programs in developing countries]. Enferm Infecc Microbiol Clin 2012; 31:100-7. [PMID: 22560588 DOI: 10.1016/j.eimc.2012.03.008] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2011] [Revised: 12/30/2011] [Accepted: 03/16/2012] [Indexed: 11/22/2022]
Abstract
As access to antiretroviral treatment increases in the developing countries, efforts towards making it easier and less costly to collect, store, and deliver the biological samples to reference laboratories, where the serological and genetic diagnosis techniques are performed, have become a high priority. Blood sampling on filter papers is an inexpensive and practical alternative to plasma for antiretroviral treatment monitoring in countries with limited resources and no access to cold chains or refrigeration. The main clinical applications and uses of blood-sampling onto filter papers (dried blood spots [DBS]) are reviewed, focusing on how these can be applied in monitoring HIV infection, particularly for use in National Health Programs in developing countries, or in resource-limited settings. A review is presented of studies that have used the DBS technique for quantifying viral load, analysis of antiretroviral drug-resistance mutations, early infant diagnosis, adult serological diagnosis, detection of viral p24 antigen, and molecular epidemiology of HIV-1, in different geographical locations. Those variables that could affect the use of DBS, particularly in the HIV field, as well as explaining how these procedures can be optimised to increase their sensitivity are also reviewed. The aim of this study was to review the advantages of implementing the DBS technique in the HIV field, especially in resource-constrained regions.
Collapse
|
17
|
Anitha D, Jacob SM, Ganesan A, Sushi KM. Diagnosis of HIV-1 infection in infants using dried blood spots in Tamil Nadu, South India. Indian J Sex Transm Dis AIDS 2011; 32:99-102. [PMID: 22021971 DOI: 10.4103/0253-7184.85413] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
INTRODUCTION Diagnosis of HIV infection in infants is difficult due to the presence of maternal antibodies; only nucleic acid assays are very helpful in early detection. Filter papers are especially useful for blood collection in resource-poor settings with limited access to diagnostic facilities. MATERIALS #ENTITYSTARTX00026; METHODS DBS samples were collected from the infants born to HIV seropositive mothers who had received single dose nevirapine at onset of labor. The samples were directly spotted onto the Whatman 903 cards from heel, big toe or finger prick depending on the age of the infants. A total of 766 infant samples were collected on dried blood spots (DBS) and transported to the Department of Experimental Medicine (DEM), Chennai, for testing from different government hospitals of rural and urban parts of Tamil Nadu, South India. According to National AIDS Control Organization's (NACO) protocol DNA was extracted from all these DBS and PCR was performed using the Roche kit version 1.5. RESULTS Fifteen infants were found to be HIV positive and 751 were HIV negative; all these 15 positive infants and 49 negative infants who were in the age group between 10 and 18 months were repeated with another DBS and compared with whole blood. The DBS results were concordant with the whole blood method and the sensitivity and specificity were 100%.
Collapse
Affiliation(s)
- D Anitha
- Department of Experimental Medicine, The Tamil Nadu Dr. M G R Medical University, Chennai, India
| | | | | | | |
Collapse
|
18
|
Anitha D, Jacob SM, Ganesan A, Sushi KM. Diagnosis of HIV-1 infection in infants using dried blood spots in Tamil Nadu, South India. Indian J Sex Transm Dis AIDS 2011. [PMID: 22021971 PMCID: PMC3195190 DOI: 10.4103/2589-0557.85413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
INTRODUCTION Diagnosis of HIV infection in infants is difficult due to the presence of maternal antibodies; only nucleic acid assays are very helpful in early detection. Filter papers are especially useful for blood collection in resource-poor settings with limited access to diagnostic facilities. MATERIALS #ENTITYSTARTX00026; METHODS DBS samples were collected from the infants born to HIV seropositive mothers who had received single dose nevirapine at onset of labor. The samples were directly spotted onto the Whatman 903 cards from heel, big toe or finger prick depending on the age of the infants. A total of 766 infant samples were collected on dried blood spots (DBS) and transported to the Department of Experimental Medicine (DEM), Chennai, for testing from different government hospitals of rural and urban parts of Tamil Nadu, South India. According to National AIDS Control Organization's (NACO) protocol DNA was extracted from all these DBS and PCR was performed using the Roche kit version 1.5. RESULTS Fifteen infants were found to be HIV positive and 751 were HIV negative; all these 15 positive infants and 49 negative infants who were in the age group between 10 and 18 months were repeated with another DBS and compared with whole blood. The DBS results were concordant with the whole blood method and the sensitivity and specificity were 100%.
Collapse
Affiliation(s)
- D. Anitha
- Department of Experimental Medicine, The Tamil Nadu Dr. M G R Medical University, Chennai, India,Address for correspondence: Dr D. Anitha, Department of Experimental Medicine, The Tamil Nadu Dr. M G R Medical University, Chennai – 600 032, India. E-mail:
| | - S. Mini Jacob
- Department of Experimental Medicine, The Tamil Nadu Dr. M G R Medical University, Chennai, India
| | - A. Ganesan
- Department of Experimental Medicine, The Tamil Nadu Dr. M G R Medical University, Chennai, India
| | - K. Mary Sushi
- Department of Experimental Medicine, The Tamil Nadu Dr. M G R Medical University, Chennai, India
| |
Collapse
|
19
|
Cross-contamination during processing of dried blood spots used for rapid diagnosis of HIV-1 infection of infants is rare and avoidable. J Virol Methods 2009; 163:489-91. [PMID: 19878694 DOI: 10.1016/j.jviromet.2009.10.016] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2009] [Revised: 10/13/2009] [Accepted: 10/19/2009] [Indexed: 11/23/2022]
Abstract
Dried blood spot (DBS) samples are a convenient way to collect infant blood for HIV-1 diagnostic testing. Minimizing the risk of false positives is critical for diagnostic tests. A protocol for processing and testing DBS for infant HIV-1 diagnosis was evaluated to identify the rate and source of false-positive results. DBS were created on Flinders Technology Associates (FTA) filter paper with 500 copies/punch (high) or 5000 copies/punch (very high) concentrations of HIV-1 DNA. Blank discs of filter paper punched after DBS samples were tested for carry-over of HIV-1 DNA using nested PCR for the pol region. No false positives were detected in the 40 series using high concentration DBS. In series with very high concentrations of HIV-1, 8/246 (3%) reactions were falsely positive. When tubes were spun prior to opening, contact with caps minimized, and spaces left between lanes of the gel, repeat second-round PCR of five false positives resulted in only one repeat false-positive PCR. This study outlines procedures that minimize false-positive results for nested PCR of HIV-1 DNA from DBS.
Collapse
|
20
|
Detection of low levels of human immunodeficiency virus (HIV) may be critical for early diagnosis of pediatric HIV infection by use of dried blood spots. J Clin Microbiol 2009; 47:2989-91. [PMID: 19625479 DOI: 10.1128/jcm.02453-08] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
We compared a DNA-based assay with a total nucleic acid-based assay for early detection of infant human immunodeficiency virus (HIV) infection. The codetection of DNA and RNA did not result in an overall higher sensitivity compared to that of DNA alone. Discordant results were associated with low levels of HIV DNA, indicating that the sample amount may be critical.
Collapse
|
21
|
Leelawiwat W, Young NL, Chaowanachan T, Ou CY, Culnane M, Vanprapa N, Waranawat N, Wasinrapee P, Mock PA, Tappero J, McNicholl JM. Dried blood spots for the diagnosis and quantitation of HIV-1: stability studies and evaluation of sensitivity and specificity for the diagnosis of infant HIV-1 infection in Thailand. J Virol Methods 2008; 155:109-17. [PMID: 18952125 DOI: 10.1016/j.jviromet.2008.09.022] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2008] [Revised: 09/18/2008] [Accepted: 09/25/2008] [Indexed: 10/21/2022]
Abstract
Molecular methods for HIV-1 infection using dried blood-spot (DBS) for HIV-1 CRF01_AE subtypes have not been fully optimized. In this study assays for HIV-1 diagnosis or quantitation were evaluated using infant DBS from Thailand. Paired DBS and whole blood samples from 56 HIV-1 CRF01_AE or B'-infected infants were tested for infant diagnosis using modified Amplicor DNA PCR and NucliSens RNA NASBA and an in-house real-time PCR assay. The Amplicor Monitor viral load (VL) assay, with modifications for DBS, was also evaluated. DBS VL were hematocrit corrected. Stability studies were done on DBS stored at -70 degrees C to 37 degrees C for up to 1 year. The DBS diagnostic assays were 96-100% sensitive and 100% specific for HIV-1 diagnosis. DBS HIV-1 VL were highly correlated with plasma VL when corrected using the actual or an assumed hematocrit factor (r(c)=0.88 or 0.93, respectively). HIV-1 DNA in DBS appeared to be more stable than RNA and could be detected after up to 9 months at most temperatures. DBS VL could be consistently determined when stored frozen. These results show that DBS can be used accurately instead of whole blood for the diagnosis of HIV-1 infection and VL quantitation, particularly if samples are appropriately stored.
Collapse
Affiliation(s)
- W Leelawiwat
- The Thai Ministry of Public Health - U.S. Centers for Disease Control and Prevention Collaboration, Nonthaburi, Thailand.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|