1
|
Rodríguez‐Temporal D, Zvezdánova ME, Benedí P, Marín M, Blázquez‐Sánchez M, Ruiz‐Serrano MJ, Muñoz P, Rodríguez‐Sánchez B. Identification of Nocardia and non-tuberculous Mycobacterium species by MALDI-TOF MS using the VITEK MS coupled to IVD and RUO databases. Microb Biotechnol 2023; 16:778-783. [PMID: 36541026 PMCID: PMC10034632 DOI: 10.1111/1751-7915.14146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 06/22/2022] [Accepted: 09/01/2022] [Indexed: 12/24/2022] Open
Abstract
Identification of Nocardia and Mycobacterium species by matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) is still a challenging task that requires both suitable protein extraction procedures and extensive databases. This study aimed to evaluate the VITEK MS Plus system coupled with updated RUO (v4.17) and IVD (v3.2) databases for the identification of Nocardia spp. and Mycobacterium spp. clinical isolates. Sample preparation was carried out using the VITEK MS Mycobacterium/Nocardia kit for protein extraction. From 90 Nocardia spp. isolates analysed, 86 (95.6%) were correctly identified at species or complex level using IVD and 78 (86.7%) using RUO. Only two strains were misidentified as other species pertaining to the same complex. Among the 106 non-tuberculous Mycobacterium clinical isolates tested from a liquid culture medium, VITEK MS identified correctly at species or complex level 96 (90.6%) isolates in the IVD mode and 89 (84.0%) isolates in the RUO mode. No misidentifications were detected. Although the IVD mode was unable to differentiate members of the M. fortuitum complex, the RUO mode correctly discriminated M. peregrinum and M. septicum. The robustness and accuracy showed by this system allow its implementation for routine identification of these microorganisms in clinical laboratories.
Collapse
Affiliation(s)
- David Rodríguez‐Temporal
- Clinical Microbiology and Infectious Diseases DepartmentHospital General Universitario Gregorio MarañónMadridSpain
- Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM)MadridSpain
| | - Margarita Estreya Zvezdánova
- Clinical Microbiology and Infectious Diseases DepartmentHospital General Universitario Gregorio MarañónMadridSpain
- Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM)MadridSpain
| | - Pablo Benedí
- Clinical Microbiology and Infectious Diseases DepartmentHospital General Universitario Gregorio MarañónMadridSpain
- Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM)MadridSpain
| | - Mercedes Marín
- Clinical Microbiology and Infectious Diseases DepartmentHospital General Universitario Gregorio MarañónMadridSpain
- Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM)MadridSpain
- CIBER de Enfermedades Respiratorias (CIBERES CB06/06/0058)MadridSpain
| | - Mario Blázquez‐Sánchez
- Clinical Microbiology and Infectious Diseases DepartmentHospital General Universitario Gregorio MarañónMadridSpain
- Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM)MadridSpain
| | - María Jesús Ruiz‐Serrano
- Clinical Microbiology and Infectious Diseases DepartmentHospital General Universitario Gregorio MarañónMadridSpain
| | - Patricia Muñoz
- Clinical Microbiology and Infectious Diseases DepartmentHospital General Universitario Gregorio MarañónMadridSpain
- Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM)MadridSpain
- CIBER de Enfermedades Respiratorias (CIBERES CB06/06/0058)MadridSpain
- Medicine Department, Faculty of MedicineUniversidad Complutense de MadridMadridSpain
| | - Belén Rodríguez‐Sánchez
- Clinical Microbiology and Infectious Diseases DepartmentHospital General Universitario Gregorio MarañónMadridSpain
- Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM)MadridSpain
| |
Collapse
|
2
|
Pan F, Zhao N, Zhao W, Wang C, Sun Y, Zhang H, Qin J, Liu Q, Zhang H. Performance of Two Matrix-Assisted Laser Desorption Ionization-Time-of-Flight Mass Spectrometry (MALDI-TOF MS) Systems for Identification of the Viridans Group Streptococci. Infect Drug Resist 2023; 16:2901-2909. [PMID: 37193297 PMCID: PMC10183192 DOI: 10.2147/idr.s407667] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Accepted: 04/20/2023] [Indexed: 05/18/2023] Open
Abstract
Background Due to similar colony morphology among viridans group streptococci (VGS), the differentiation of VGS species remains difficult in routine clinical microbiology. Recently, matrix-assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI-TOF MS) has been described as a fast method for identifying various bacteria at species level, and also for the VGS strains. Methods A total of 277 VGS isolates were identified with the two MALDI-TOF MS systems (VITEK MS and Bruker Biotyper). The tuf and rpoB gene sequencing was used as the reference identification method for comparison. Results Based on tuf and rpoB gene sequencing, 84 isolates were S. pneumoniae and 193 strains were other VGS isolates including S. anginosus group (n=91, 47.2%), S. mitis group (n=80, 41.5%), S. bovis group (n=11, 5.7%), S. salivarius group (n=10, 5.2%), and S. mutans group (n=1, 0.5%). VITEK MS and Bruker Biotyper accurately identified 94.6% and 89.9% of all VGS isolates, respectively. VITEK MS showed better identification results than Bruker Biotyper for S. mitis group including S. pneumoniae and S. bovis group, but for other VGS isolates, two MALDI-TOF MS systems showed comparable identification performance. However, VITEK MS was able to identify S. gallolyticus to the subspecies level with high-confidence (S. gallolyticus ssp. pasteurianus), while the Bruker Biotyper system could not. While Bruker Biotyper system could be able to correctly differentiate the subspecies of S. salivarius from S. vestibularis, VITEK MS poorly identify. Conclusion This study demonstrated that two MALDI-TOF MS systems allowed discrimination for most VGS isolates with different identification performance, but Bruker Biotyper could produce more misidentifications and VITEK MS system. It is crucial to be familiar with the performance of MALDI-TOF MS systems used in clinical microbiology.
Collapse
Affiliation(s)
- Fen Pan
- Department of Clinical Laboratory, Shanghai Children’s Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People’s Republic of China
- Institute of Pediatric Infection, Immunity, and Critical Care Medicine, Shanghai Jiao Tong University School of Medicine, Shanghai, 200062, People’s Republic of China
| | - Na Zhao
- Department of Laboratory Medicine, RenJi Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, 200127, People’s Republic of China
| | - Wantong Zhao
- Department of Clinical Laboratory, Shanghai Children’s Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People’s Republic of China
| | - Chun Wang
- Department of Clinical Laboratory, Shanghai Children’s Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People’s Republic of China
| | - Yan Sun
- Department of Clinical Laboratory, Shanghai Children’s Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People’s Republic of China
| | - Haomin Zhang
- Department of Laboratory Medicine, RenJi Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, 200127, People’s Republic of China
| | - Juanxiu Qin
- Department of Laboratory Medicine, RenJi Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, 200127, People’s Republic of China
| | - Qian Liu
- Department of Laboratory Medicine, RenJi Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, 200127, People’s Republic of China
- Qian Liu, Department of Laboratory Medicine, RenJi Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, 200127, People’s Republic of China, Email
| | - Hong Zhang
- Department of Clinical Laboratory, Shanghai Children’s Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People’s Republic of China
- Institute of Pediatric Infection, Immunity, and Critical Care Medicine, Shanghai Jiao Tong University School of Medicine, Shanghai, 200062, People’s Republic of China
- Correspondence: Hong Zhang, Department of Clinical Laboratory, Shanghai Children’s Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People’s Republic of China, Tel +86 189 1712 8200, Email
| |
Collapse
|
3
|
Traxler RM, Bell ME, Lasker B, Headd B, Shieh WJ, McQuiston JR. Updated Review on Nocardia Species: 2006-2021. Clin Microbiol Rev 2022; 35:e0002721. [PMID: 36314911 PMCID: PMC9769612 DOI: 10.1128/cmr.00027-21] [Citation(s) in RCA: 28] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
This review serves as an update to the previous Nocardia review by Brown-Elliott et al. published in 2006 (B. A. Brown-Elliott, J. M. Brown, P. S. Conville, and R. J. Wallace. Jr., Clin Microbiol Rev 19:259-282, 2006, https://doi.org/10.1128/CMR.19.2.259-282.2006). Included is a discussion on the taxonomic expansion of the genus, current identification methods, and the impact of new technology (including matrix-assisted laser desorption ionization-time of flight [MALDI-TOF] and whole genome sequencing) on diagnosis and treatment. Clinical manifestations, the epidemiology, and geographic distribution are briefly discussed. An additional section on actinomycotic mycetoma is added to address this often-neglected disease.
Collapse
Affiliation(s)
- Rita M. Traxler
- Bacterial Special Pathogens Branch (BSPB), Division of High-Consequence Pathogens and Pathology (DHCPP), National Center for Emerging and Zoonotic Infectious Diseases (NCEZID), Centers for Disease Control and Prevention (CDC), Atlanta, Georgia, USA
| | - Melissa E. Bell
- Bacterial Special Pathogens Branch (BSPB), Division of High-Consequence Pathogens and Pathology (DHCPP), National Center for Emerging and Zoonotic Infectious Diseases (NCEZID), Centers for Disease Control and Prevention (CDC), Atlanta, Georgia, USA
| | - Brent Lasker
- Bacterial Special Pathogens Branch (BSPB), Division of High-Consequence Pathogens and Pathology (DHCPP), National Center for Emerging and Zoonotic Infectious Diseases (NCEZID), Centers for Disease Control and Prevention (CDC), Atlanta, Georgia, USA
| | - Brendan Headd
- Bacterial Special Pathogens Branch (BSPB), Division of High-Consequence Pathogens and Pathology (DHCPP), National Center for Emerging and Zoonotic Infectious Diseases (NCEZID), Centers for Disease Control and Prevention (CDC), Atlanta, Georgia, USA
| | - Wun-Ju Shieh
- Infectious Diseases Pathology Branch (IDPB), Division of High-Consequence Pathogens and Pathology (DHCPP), National Center for Emerging and Zoonotic Infectious Diseases (NCEZID), Centers for Disease Control and Prevention (CDC), Atlanta, Georgia, USA
| | - John R. McQuiston
- Bacterial Special Pathogens Branch (BSPB), Division of High-Consequence Pathogens and Pathology (DHCPP), National Center for Emerging and Zoonotic Infectious Diseases (NCEZID), Centers for Disease Control and Prevention (CDC), Atlanta, Georgia, USA
| |
Collapse
|
4
|
Rindi L, Puglisi V, Franconi I, Fais R, Lupetti A. Rapid and Accurate Identification of Nontuberculous Mycobacteria Directly from Positive Primary MGIT Cultures by MALDI-TOF MS. Microorganisms 2022; 10:microorganisms10071447. [PMID: 35889166 PMCID: PMC9317365 DOI: 10.3390/microorganisms10071447] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Revised: 07/08/2022] [Accepted: 07/16/2022] [Indexed: 11/16/2022] Open
Abstract
Over the last years, nontuberculous mycobacteria (NTM) have emerged as important human pathogens. Accurate and rapid mycobacterial species identification is needed to successfully diagnose, treat, and manage infections caused by NTM. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry, MALDI-TOF MS, was demonstrated to effectively identify mycobacteria isolates subcultured from solid or liquid media rather than new positive cultures. The present study aims to develop a new extraction protocol to yield rapid and accurate identification of NTM from primary MGIT cultures by MALDI-TOF MS. A total of 60 positive MGIT broths were examined by the Bruker Biotyper system with Mycobacteria Library v. 2.0 (Bruker Daltonics GmbH & Co. KG., Bremen, Germany). The results were compared with those obtained by the molecular method, line probe assay GenoType Mycobacterium CM/AS/NTM-DR. All samples were concordantly identified by MALDI-TOF MS and the molecular test for all the tested mycobacteria. Fifty-seven (95%) MGIT positive cultures for NTM from clinical samples had a MALDI-TOF MS analysis score S ≥ 1.8. Although a small number of strains and a limited diversity of mycobacterial species were analysed, our results suggest that MALDI-TOF MS could represent a promising routine diagnostic tool for identifying mycobacterial species directly from primary liquid culture.
Collapse
Affiliation(s)
- Laura Rindi
- Dipartimento di Ricerca Traslazionale e delle Nuove Tecnologie in Medicina e Chirurgia, Università di Pisa, 56126 Pisa, Italy; (I.F.); (A.L.)
- Correspondence: author:
| | - Vincenzo Puglisi
- SD Microbiologia Micologica, Azienda Ospedaliero-Universitaria Pisana, 56126 Pisa, Italy; (V.P.); (R.F.)
| | - Iacopo Franconi
- Dipartimento di Ricerca Traslazionale e delle Nuove Tecnologie in Medicina e Chirurgia, Università di Pisa, 56126 Pisa, Italy; (I.F.); (A.L.)
| | - Roberta Fais
- SD Microbiologia Micologica, Azienda Ospedaliero-Universitaria Pisana, 56126 Pisa, Italy; (V.P.); (R.F.)
| | - Antonella Lupetti
- Dipartimento di Ricerca Traslazionale e delle Nuove Tecnologie in Medicina e Chirurgia, Università di Pisa, 56126 Pisa, Italy; (I.F.); (A.L.)
| |
Collapse
|
5
|
Draft Genome Sequence of a Mycobacterium Strain Isolated from a Clinical Wound Sample. Microbiol Resour Announc 2022; 11:e0017022. [PMID: 35652667 PMCID: PMC9302174 DOI: 10.1128/mra.00170-22] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
We report the draft genome sequence of an unusual Mycobacterium isolate recovered from a patient’s arm tissue. The 4,025,753-bp draft genome exhibits a GC content of 71.02%, and a 16S rRNA gene analysis found that the closest relative was Mycobacterium grossiae.
Collapse
|
6
|
Application and Perspectives of MALDI-TOF Mass Spectrometry in Clinical Microbiology Laboratories. Microorganisms 2021; 9:microorganisms9071539. [PMID: 34361974 PMCID: PMC8307939 DOI: 10.3390/microorganisms9071539] [Citation(s) in RCA: 55] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Revised: 07/06/2021] [Accepted: 07/18/2021] [Indexed: 12/11/2022] Open
Abstract
Early diagnosis of severe infections requires of a rapid and reliable diagnosis to initiate appropriate treatment, while avoiding unnecessary antimicrobial use and reducing associated morbidities and healthcare costs. It is a fact that conventional methods usually require more than 24–48 h to culture and profile bacterial species. Mass spectrometry (MS) is an analytical technique that has emerged as a powerful tool in clinical microbiology for identifying peptides and proteins, which makes it a promising tool for microbial identification. Matrix assisted laser desorption ionization–time of flight MS (MALDI–TOF MS) offers a cost- and time-effective alternative to conventional methods, such as bacterial culture and even 16S rRNA gene sequencing, for identifying viruses, bacteria and fungi and detecting virulence factors and mechanisms of resistance. This review provides an overview of the potential applications and perspectives of MS in clinical microbiology laboratories and proposes its use as a first-line method for microbial identification and diagnosis.
Collapse
|
7
|
Chen XF, Hou X, Xiao M, Zhang L, Cheng JW, Zhou ML, Huang JJ, Zhang JJ, Xu YC, Hsueh PR. Matrix-Assisted Laser Desorption/Ionization Time of Flight Mass Spectrometry (MALDI-TOF MS) Analysis for the Identification of Pathogenic Microorganisms: A Review. Microorganisms 2021; 9:microorganisms9071536. [PMID: 34361971 PMCID: PMC8304613 DOI: 10.3390/microorganisms9071536] [Citation(s) in RCA: 43] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2021] [Revised: 07/03/2021] [Accepted: 07/10/2021] [Indexed: 12/13/2022] Open
Abstract
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been used in the field of clinical microbiology since 2010. Compared with the traditional technique of biochemical identification, MALDI-TOF MS has many advantages, including convenience, speed, accuracy, and low cost. The accuracy and speed of identification using MALDI-TOF MS have been increasing with the development of sample preparation, database enrichment, and algorithm optimization. MALDI-TOF MS has shown promising results in identifying cultured colonies and rapidly detecting samples. MALDI-TOF MS has critical research applications for the rapid detection of highly virulent and drug-resistant pathogens. Here we present a scientific review that evaluates the performance of MALDI-TOF MS in identifying clinical pathogenic microorganisms. MALDI-TOF MS is a promising tool in identifying clinical microorganisms, although some aspects still require improvement.
Collapse
Affiliation(s)
- Xin-Fei Chen
- Department of Laboratory Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100730, China; (X.-F.C.); (X.H.); (M.X.); (L.Z.); (M.-L.Z.); (J.-J.H.); (J.-J.Z.)
- Graduate School, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China
- Beijing Key Laboratory for Mechanisms Research and Precision Diagnosis of Invasive Fungal Diseases, Beijing 100730, China
| | - Xin Hou
- Department of Laboratory Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100730, China; (X.-F.C.); (X.H.); (M.X.); (L.Z.); (M.-L.Z.); (J.-J.H.); (J.-J.Z.)
- Beijing Key Laboratory for Mechanisms Research and Precision Diagnosis of Invasive Fungal Diseases, Beijing 100730, China
| | - Meng Xiao
- Department of Laboratory Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100730, China; (X.-F.C.); (X.H.); (M.X.); (L.Z.); (M.-L.Z.); (J.-J.H.); (J.-J.Z.)
- Beijing Key Laboratory for Mechanisms Research and Precision Diagnosis of Invasive Fungal Diseases, Beijing 100730, China
| | - Li Zhang
- Department of Laboratory Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100730, China; (X.-F.C.); (X.H.); (M.X.); (L.Z.); (M.-L.Z.); (J.-J.H.); (J.-J.Z.)
- Beijing Key Laboratory for Mechanisms Research and Precision Diagnosis of Invasive Fungal Diseases, Beijing 100730, China
| | - Jing-Wei Cheng
- Center of Clinical Laboratory, Beijing Friendship Hospital, Capital Medical University, Beijing 100053, China;
| | - Meng-Lan Zhou
- Department of Laboratory Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100730, China; (X.-F.C.); (X.H.); (M.X.); (L.Z.); (M.-L.Z.); (J.-J.H.); (J.-J.Z.)
- Beijing Key Laboratory for Mechanisms Research and Precision Diagnosis of Invasive Fungal Diseases, Beijing 100730, China
| | - Jing-Jing Huang
- Department of Laboratory Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100730, China; (X.-F.C.); (X.H.); (M.X.); (L.Z.); (M.-L.Z.); (J.-J.H.); (J.-J.Z.)
- Graduate School, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China
- Beijing Key Laboratory for Mechanisms Research and Precision Diagnosis of Invasive Fungal Diseases, Beijing 100730, China
| | - Jing-Jia Zhang
- Department of Laboratory Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100730, China; (X.-F.C.); (X.H.); (M.X.); (L.Z.); (M.-L.Z.); (J.-J.H.); (J.-J.Z.)
- Beijing Key Laboratory for Mechanisms Research and Precision Diagnosis of Invasive Fungal Diseases, Beijing 100730, China
| | - Ying-Chun Xu
- Department of Laboratory Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100730, China; (X.-F.C.); (X.H.); (M.X.); (L.Z.); (M.-L.Z.); (J.-J.H.); (J.-J.Z.)
- Beijing Key Laboratory for Mechanisms Research and Precision Diagnosis of Invasive Fungal Diseases, Beijing 100730, China
- Correspondence: (Y.-C.X.); (P.-R.H.)
| | - Po-Ren Hsueh
- Departments of Laboratory Medicine and Internal Medicine, China Medical University Hospital, School of Medicine, China Medical University, Taichung 40447, Taiwan;
- Departments of Laboratory Medicine and Internal Medicine, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei 100, Taiwan
- Correspondence: (Y.-C.X.); (P.-R.H.)
| |
Collapse
|
8
|
Sulaiman IM, Miranda N, Simpson S. MALDI-TOF Mass Spectrometry and 16S rRNA Gene Sequence Analysis for the Identification of Foodborne Clostridium Spp. J AOAC Int 2021; 104:1381-1388. [PMID: 33982069 DOI: 10.1093/jaoacint/qsab070] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 04/21/2021] [Accepted: 05/03/2021] [Indexed: 11/14/2022]
Abstract
BACKGROUND Clostridium is a genus of Gram-positive, spore-forming, anaerobic bacteria comprising approximately 100 species. Some Clostridium spp. (C. botulinum, C. perfringens, C. tetani and C. difficile) were recognized to cause acute food poisoning, botulism, tetanus, and diarrheal illness in humans. Thus, rapid identification of Clostridium spp. is critical for source tracking of contaminated food and to understand the transmission dynamics of these foodborne pathogens. OBJECTIVE This study was carried out to rapidly identify Clostridium-like isolates by MALDI-TOF MS and rRNA sequencing methods. METHODS Thirty-three Clostridium-like isolates were recovered from various baby food and surveillance samples. Species identification of these isolates was accomplished using VITEK MS system. Sequence characterization of the 16S rRNA region was done on an ABI 3500XL Genetic Analyzer. RESULTS The VITEK MS system identified 28 of the 33 Clostridium-like isolates with a high confidence value (99.9%); no ID was observed for the rest of the five isolates. Nucleotide sequencing of 16S rRNA region identified all 33 Clostridium-like isolates. Furthermore, while characterizing the 16S rRNA gene, eleven distinct Clostridium spp. (Clostridium aciditolerans, Clostridium aerotolerans, Clostridium argentinense, Clostridium beijerinckii, Clostridium bifermentans, Clostridium butyricum, Clostridium cochlearium, Clostridium difficile, Clostridium perfringens, Clostridium sporogenes, and Clostridium subterminale) were recognized among the 33 Clostridium-like isolates. One of the Clostridium-like isolate was identified as the Citrobacter amalonaticus by both diagnostic methods. The generated 16S rRNA sequences matched completely (100%) with sequences available in GenBank for Clostridium and Citrobacter species. Species identification attained by the VITEK MS for the Clostridium-like isolates was comparable to the 16S rRNA sequencing based data. HIGHLIGHTS MALDI-TOF mass spectrometry and 16S rRNA sequencing can be used in the species identification of Clostridium species.
Collapse
Affiliation(s)
- Irshad M Sulaiman
- U.S. Food and Drug Administration, Microbiological Sciences Branch, Southeast Food and Feed Laboratory, Office of Regulatory Science, Office of Regulatory Affairs, 60 8th Street NE, Atlanta, GA, 30309, USA
| | - Nancy Miranda
- U.S. Food and Drug Administration, Microbiological Sciences Branch, Southeast Food and Feed Laboratory, Office of Regulatory Science, Office of Regulatory Affairs, 60 8th Street NE, Atlanta, GA, 30309, USA
| | - Steven Simpson
- U.S. Food and Drug Administration, Microbiological Sciences Branch, Southeast Food and Feed Laboratory, Office of Regulatory Science, Office of Regulatory Affairs, 60 8th Street NE, Atlanta, GA, 30309, USA
| |
Collapse
|
9
|
Solntceva V, Kostrzewa M, Larrouy-Maumus G. Detection of Species-Specific Lipids by Routine MALDI TOF Mass Spectrometry to Unlock the Challenges of Microbial Identification and Antimicrobial Susceptibility Testing. Front Cell Infect Microbiol 2021; 10:621452. [PMID: 33634037 PMCID: PMC7902069 DOI: 10.3389/fcimb.2020.621452] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Accepted: 12/18/2020] [Indexed: 12/16/2022] Open
Abstract
MALDI-TOF mass spectrometry has revolutionized clinical microbiology diagnostics by delivering accurate, fast, and reliable identification of microorganisms. It is conventionally based on the detection of intracellular molecules, mainly ribosomal proteins, for identification at the species-level and/or genus-level. Nevertheless, for some microorganisms (e.g., for mycobacteria) extensive protocols are necessary in order to extract intracellular proteins, and in some cases a protein-based approach cannot provide sufficient evidence to accurately identify the microorganisms within the same genus (e.g., Shigella sp. vs E. coli and the species of the M. tuberculosis complex). Consequently lipids, along with proteins are also molecules of interest. Lipids are ubiquitous, but their structural diversity delivers complementary information to the conventional protein-based clinical microbiology matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) based approaches currently used. Lipid modifications, such as the ones found on lipid A related to polymyxin resistance in Gram-negative pathogens (e.g., phosphoethanolamine and aminoarabinose), not only play a role in the detection of microorganisms by routine MALDI-TOF mass spectrometry but can also be used as a read-out of drug susceptibility. In this review, we will demonstrate that in combination with proteins, lipids are a game-changer in both the rapid detection of pathogens and the determination of their drug susceptibility using routine MALDI-TOF mass spectrometry systems.
Collapse
Affiliation(s)
- Vera Solntceva
- MRC Centre for Molecular Bacteriology and Infection, Department of Life Sciences, Faculty of Natural Sciences, Imperial College London, London, United Kingdom
| | | | - Gerald Larrouy-Maumus
- MRC Centre for Molecular Bacteriology and Infection, Department of Life Sciences, Faculty of Natural Sciences, Imperial College London, London, United Kingdom
| |
Collapse
|
10
|
Usefulness of matrix-assisted laser desorption ionization/time of flight mass spectrometry for the identification of Streptococcus mutans. Appl Microbiol Biotechnol 2020; 104:10601-10612. [PMID: 33141297 DOI: 10.1007/s00253-020-10980-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2020] [Revised: 10/19/2020] [Accepted: 10/26/2020] [Indexed: 10/23/2022]
Abstract
This study evaluated the reliability of MALDI-TOF MS coupled with statistical tools for the identification of Streptococcus mutans in comparison with PCR-based techniques. Bacterial isolates were identified and serotyped by conventional PCR, using S. mutans species and serotype-specific primers. For bacterial identification, mass spectra data from S. mutans and other streptococci were compared with Biotyper V 3.1 database and the mass peak lists were examined by cluster and principal component (PCA) analysis. Identification of potential biomarkers was performed using UniProtKB/Swiss-Prot and UniProtKB/TrEMBL databases and BLAST tool of the NCBI database. PCR identified 100% of the isolates as S. mutans. S. mutans strains were typed as serotypes c (85.6%), e (8.6%), k (4.8%), and f (0.9%). Although only the 70% of the strains tested were identified at species level by the Biotyper database, PCA and cluster analysis of mass peaks allowed the identification of 100% S. mutans isolates and its differentiation from the other oral and non-oral streptococci. One mass peak at m/z value of 9572.73 was identified as species-specific biomarker for S. mutans. No biomarkers were identified for S. mutans serotypes. KEY POINTS: • MALDI-TOF MS coupled with statistical tools for the identification of S. mutans. • Detection of species identifying biomarkers by MALDI-TOF MS. • PCR identification and serotyping of S. mutans from saliva samples.
Collapse
|
11
|
Yoo IY, Shim HJ, Yun SA, Kang OK, Chung YN, Kim TY, Lee H, Kim J, Park YJ, Huh HJ, Lee NY. Evaluation of the ASTA MicroIDSys matrix-assisted laser desorption ionization time-of-flight mass spectrometry system for identification of mycobacteria directly from positive MGIT liquid cultures. Int J Infect Dis 2020; 102:172-177. [PMID: 33039611 DOI: 10.1016/j.ijid.2020.10.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Revised: 09/30/2020] [Accepted: 10/02/2020] [Indexed: 10/23/2022] Open
Abstract
OBJECTIVES We evaluated the performance of the MicroIDSys Elite system, a newly developed matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry system for identification of mycobacteria directly from positive MGIT liquid cultures. METHODS Analytical specificity was evaluated with 63 reference strains grown in mycobacteria growth indicator tube media. Prospective performance evaluation was conducted with primary liquid cultures of sputum samples for identification of mycobacteria, and results were compared to multigenerational sequencing as the reference method. Liquid media subcultures were also analyzed. RESULTS The accuracy for the 63 reference strains was 98.4% (62/63). A total of 167 paired mycobacterial primary cultures and subcultures in liquid media, comprised of seven Mycobacterium tuberculosis isolates, 109 slowly growing nontuberculous mycobacterial isolates, and 51 rapidly growing nontuberculous mycobacterial isolates, was identified by the MicroIDSys Elite system. Using primary liquid cultures, the MicroIDSys Elite system correctly identified 143 (85.6%) isolates; 21 (12.6%) resulted in "no identification"; and three (1.8%) isolates were misidentified. Using liquid media subcultures with this system, 159 (95.2%) isolates were correctly identified; seven (4.2%) resulted in "no identification"; and one (0.6%) isolate was misidentified. CONCLUSION The MicroIDSys Elite system is a useful routine diagnostic tool for identification of mycobacterial species from liquid culture.
Collapse
Affiliation(s)
- In Young Yoo
- Department of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Hyang Jin Shim
- Center for Clinical Medicine, Samsung Biomedical Research Institute, Samsung Medical Center, Seoul, Republic of Korea
| | - Sun Ae Yun
- Center for Clinical Medicine, Samsung Biomedical Research Institute, Samsung Medical Center, Seoul, Republic of Korea
| | - On Kyun Kang
- Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Yoo Na Chung
- Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Tae Yeul Kim
- Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Hyeyoung Lee
- Department of Laboratory Medicine, International St. Mary's Hospital, College of Medicine, The Catholic Kwandong University, Incheon, Republic of Korea
| | - Jayoung Kim
- Department of Laboratory Medicine, International St. Mary's Hospital, College of Medicine, The Catholic Kwandong University, Incheon, Republic of Korea
| | - Yeon-Joon Park
- Department of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Hee Jae Huh
- Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
| | - Nam Yong Lee
- Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
| |
Collapse
|
12
|
Evaluation of MALDI Biotyper Interpretation Criteria for Accurate Identification of Nontuberculous Mycobacteria. J Clin Microbiol 2020; 58:JCM.01103-20. [PMID: 32719033 DOI: 10.1128/jcm.01103-20] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Accepted: 07/17/2020] [Indexed: 12/27/2022] Open
Abstract
Identification of mycobacteria by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) requires not only a good protein extraction protocol but also an adequate cutoff score in order to provide reliable results. The aim of this study was to assess the cutoff scores proposed by the MALDI-TOF MS system for mycobacterial identification. A total of 693 clinical isolates from a liquid medium and 760 from a solid medium were analyzed, encompassing 67 different species of nontuberculous mycobacteria (NTM). MALDI-TOF MS identified 558 (80.5%) isolates from the liquid medium and 712 (93.7%) isolates from the solid medium with scores of ≥1.60. Among these, four (0.7%) misidentifications were obtained from the liquid medium and four (0.5%) from the solid medium. With regard to species diversity, MALDI-TOF MS successfully identified 64 (95.5%) different species, while PCR-reverse hybridization (GenoType Mycobacterium CM and AS assays) identified 24 (35.8%) different species. With MALDI-TOF MS scores of ≥2, all isolates were correctly identified, and with scores in the range from 1.60 to 1.99, most isolates were correctly identified, except for Mycobacterium angelicum, M. parascrofulaceum, M. peregrinum, M. porcinum, and M. gastri In conclusion, MALDI-TOF MS is a useful method for identifying a large diversity of NTM species. A score threshold of 1.60 proved useful for identifying almost all the isolates tested; only a few species required a higher score (≥2.00) to obtain a valid definitive identification.
Collapse
|
13
|
Holmes DT, Romney MG, Angel P, DeMarco ML. Proteomic applications in pathology and laboratory medicine: Present state and future prospects. Clin Biochem 2020; 82:12-20. [PMID: 32442429 DOI: 10.1016/j.clinbiochem.2020.05.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2020] [Revised: 05/13/2020] [Accepted: 05/13/2020] [Indexed: 12/11/2022]
Abstract
Clinical mass spectrometry applications have traditionally focused on small molecules, particularly in the areas of therapeutic drug monitoring, toxicology, and measurement of endogenous and exogenous steroids. More recently, the use of matrix assisted laser desorption/ionization time of flight mass spectrometry for the identification of microbial pathogens has been widely implemented. Following this evolution, there has been an expanding role for the measurement of peptides and proteins in pathology and laboratory medicine. This review explores the current state of protein measurement by clinical mass spectrometry and the analytical strategies employed, as well as emerging applications in clinical chemistry, clinical microbiology and anatomical pathology.
Collapse
Affiliation(s)
- Daniel T Holmes
- Department of Pathology and Laboratory Medicine, St. Paul's Hospital, 1081 Burrard St, Vancouver, BC V6Z 1Y6, Canada; University of British Columbia Department of Pathology and Laboratory Medicine, Vancouver, BC V6T 2B5 Canada.
| | - Marc G Romney
- Department of Pathology and Laboratory Medicine, St. Paul's Hospital, 1081 Burrard St, Vancouver, BC V6Z 1Y6, Canada; University of British Columbia Department of Pathology and Laboratory Medicine, Vancouver, BC V6T 2B5 Canada.
| | - Peggi Angel
- Department of Cell and Molecular Pharmacology and Experimental Therapeutics, Medical University of South Carolina, Charelston, SC 29425 Canada.
| | - Mari L DeMarco
- Department of Pathology and Laboratory Medicine, St. Paul's Hospital, 1081 Burrard St, Vancouver, BC V6Z 1Y6, Canada; University of British Columbia Department of Pathology and Laboratory Medicine, Vancouver, BC V6T 2B5 Canada.
| |
Collapse
|
14
|
Abstract
The clinical microbiology laboratory relies on traditional diagnostic methods such as culturing, Gram stains, and biochemical testing. Receipt of a high-quality specimen with an appropriate test order is integral to accurate testing. Recent technological advancements have led to decreased time to results and improved diagnostic accuracy. Examples of advancements discussed in this chapter include automation of bacterial culture processing and incubation, as well as introduction of mass spectrometry for the proteomic identification of microorganisms. In addition, molecular testing is increasingly common in the clinical laboratory. Commercially available multiplex molecular assays simultaneously test for a broad array of syndromic-related pathogens, providing rapid and sensitive diagnostic results. Molecular advancements have also transformed point-of-care (POC) microbiology testing, and molecular POC assays may largely supplant traditional rapid antigen testing in the future. Integration of new technologies with traditional testing methods has led to improved quality and value in the clinical microbiology laboratory. After reviewing this chapter, the reader will be able to:List key considerations for specimen collection for microbiology testing. Discuss the advantages and limitations of automation in the clinical microbiology laboratory. Describe the evolution of microorganism identification methods. Discuss the benefits and limitations of molecular microbiology point-of-care testing. Summarize currently available multiplex molecular microbiology testing options.
Collapse
|
15
|
Brown-Elliott BA, Fritsche TR, Olson BJ, Vasireddy S, Vasireddy R, Iakhiaeva E, Alame D, Wallace RJ, Branda JA. Comparison of Two Commercial Matrix-Assisted Laser Desorption/Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS) Systems for Identification of Nontuberculous Mycobacteria. Am J Clin Pathol 2019; 152:527-536. [PMID: 31314059 PMCID: PMC6733354 DOI: 10.1093/ajcp/aqz073] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
OBJECTIVES This multicenter study's aim was to assess the performance of two commercially available matrix-assisted laser desorption/ionization time of flight mass spectrometry systems in identifying a challenge collection of clinically relevant nontuberculous mycobacteria (NTM). METHODS NTM clinical isolates (n = 244) belonging to 23 species/subspecies were identified by gene sequencing and analyzed using Bruker Biotyper with Mycobacterial Library v5.0.0 and bioMérieux VITEK MS with v3.0 database. RESULTS Using the Bruker or bioMérieux systems, 92% and 95% of NTM strains, respectively, were identified at least to the complex/group level; 62% and 57%, respectively, were identified to the highest taxonomic level. Differentiation between members of Mycobacterium abscessus, M fortuitum, M mucogenicum, M avium, and M terrae complexes/groups was problematic for both systems, as was identification of M chelonae for the Bruker system. CONCLUSIONS Both systems identified most NTM isolates to the group/complex level, and many to the highest taxonomic level. Performance was comparable.
Collapse
Affiliation(s)
| | - Thomas R Fritsche
- Marshfield Clinic Health System, Marshfield, WI
- University of Wisconsin, La Crosse
| | | | | | | | | | - Diana Alame
- Thomas Jefferson University, Philadelphia, PA
| | | | - John A Branda
- Massachusetts General Hospital, Boston
- Harvard Medical School, Boston, MA
| |
Collapse
|
16
|
Bryson AL, Hill EM, Doern CD. Matrix-Assisted Laser Desorption/Ionization Time-of-Flight: The Revolution in Progress. Clin Lab Med 2019; 39:391-404. [PMID: 31383264 DOI: 10.1016/j.cll.2019.05.010] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
This article summarizes recent advances in the application of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) to new areas of infectious diseases diagnostics. We discuss progress toward routine identification of mycobacteria and filamentous fungi and direct identification of pathogens from clinical specimens. Of greatest interest is the use of MALDI-TOF MS for identifying organisms from positive blood cultures and from clinical specimens such as urine. Last, We highlight some exciting new possibilities for MALDI-TOF MS phenotypic susceptibility testing for bacteria and yeast.
Collapse
Affiliation(s)
- Alexandra L Bryson
- Department of Pathology, Virginia Commonwealth University Health System, 403 North 13th Street, Richmond, VA 23298, USA
| | - Emily M Hill
- Pathology & Laboratory Medicine, Hunter Holmes McGuire VA Medical Center, 1201 Broad Rock Boulevard, Richmond, VA 23224, USA
| | - Christopher D Doern
- Department of Pathology, Virginia Commonwealth University Health System, 403 North 13th Street, Richmond, VA 23298, USA.
| |
Collapse
|
17
|
Hou TY, Chiang-Ni C, Teng SH. Current status of MALDI-TOF mass spectrometry in clinical microbiology. J Food Drug Anal 2019; 27:404-414. [PMID: 30987712 PMCID: PMC9296205 DOI: 10.1016/j.jfda.2019.01.001] [Citation(s) in RCA: 152] [Impact Index Per Article: 30.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2018] [Revised: 01/11/2019] [Accepted: 01/18/2019] [Indexed: 11/16/2022] Open
Abstract
Mass spectrometry (MS) is a type of analysis used to determine what molecules make up a sample, based on the mass spectrum that are created by the ions. Mass spectrometers are able to perform traditional target analyte identification and quantitation; however, they may also be used within a clinical setting for the rapid identification of bacteria. The causative agent in sepsis is changed over time, and clinical decisions affecting the management of infections are often based on the outcomes of bacterial identification. Therefore, it is essential that such identifications are performed quickly and interpreted correctly. Matrix-assisted laser desorption/ionization-time of flight (MALDI-TOF) mass spectrometer is one of the most popular MS instruments used in biology, due to its rapid and precise identification of genus and species of an extensive range of Gram-negative and-positive bacteria. Microorganism identification by Mass spectrometry is based on identifying a characteristic spectrum of each species and then matched with a large database within the instrument. The present review gives a contemporary perspective on the challenges and opportunities for bacterial identification as well as a written report of how technological innovation has advanced MS. Future clinical applications will also be addressed, particularly the use of MALDI-TOF MS in the field of microbiology for the identification and the analysis of antibiotic resistance.
Collapse
Affiliation(s)
- Tsung-Yun Hou
- Division of Rheumatology/Immunology/Allergy, Department of Internal Medicine, Wan Fang Hospital, Taipei Medical University, Taipei,
Taiwan
- Division of Allergy, Immunology and Rheumatology, Department of Internal Medicine, School of Medicine, College of Medicine, Taipei Medical University, Taipei,
Taiwan
- Division of Rheumatology/Immunology/Allergy, Department of Internal Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei,
Taiwan
| | - Chuan Chiang-Ni
- Department of Microbiology and Immunology, College of Medicine, Chang Gung University, Taoyuan,
Taiwan
- Graduate Institute of Biomedical Sciences, College of Medicine, Chang Gung University, Taoyuan,
Taiwan
- Molecular Infectious Disease Research Center, Chang Gung Memorial Hospital, Taoyuan,
Taiwan
| | - Shih-Hua Teng
- Bruker Taiwan Co., Ltd., Taipei,
Taiwan
- Corresponding author. 4F, 107 Yanshou Street, Songshan District, Taipei City 105, Taiwan. Fax: +886 2 2761 5335. E-mail address: (S.-H. Teng)
| |
Collapse
|
18
|
Pellegrino FLPC, Chagas TPG, Alves MS, Carvalho-Assef APD, Chapeaurouge A, Asensi MD. Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS) Applications in Bacteriology: brazilian contributions. HU REVISTA 2018. [DOI: 10.34019/1982-8047.2017.v43.2859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Among its innumerous applications in Bacteriology, the Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS) technique is evolving as a powerful tool for bacterial identification and antimicrobial resistance investigation. Publications have evaluated the MALDI-TOF MS performance in the identification of a series of bacterial pathogens, including the most common severe infectious agents, emergent pathogens involved with outbreaks of healthcare-associated infections, rare pathogens, and those whose isolation in culture media is difficult. As compared to conventional methods of bacterial identification, MALDI-TOF MS has proven to be a fast, accurate and cost-effective technique. Currently, MALDI-TOF MS has been used in antimicrobial resistance studies, since it has shown to be an efficient tool in detecting specific resistance mechanisms in bacteria, such as beta-lactamases production, for example. Here, we describe the advances in this growing field of mass spectrometry applied to Bacteriology, including Brazilian contributions.
Collapse
|
19
|
Huh HJ, Kim SY, Jhun BW, Shin SJ, Koh WJ. Recent advances in molecular diagnostics and understanding mechanisms of drug resistance in nontuberculous mycobacterial diseases. INFECTION GENETICS AND EVOLUTION 2018; 72:169-182. [PMID: 30315892 DOI: 10.1016/j.meegid.2018.10.003] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2018] [Revised: 10/08/2018] [Accepted: 10/09/2018] [Indexed: 01/31/2023]
Abstract
Accumulating evidence suggests that human infections caused by nontuberculous mycobacteria (NTM) are increasing worldwide, indicating that NTM disease is no longer uncommon in many countries. As a result of an increasing emphasis on the importance of differential identification of NTM species, several molecular tools have recently been introduced in clinical and experimental settings. These advances have led to a much better understanding of the diversity of NTM species with regard to clinical aspects and the potential factors responsible for drug resistance that influence the different outcomes of NTM disease. In this paper, we review currently available molecular diagnostics for identification and differentiation of NTM species by summarizing data from recently applied methods, including commercially available assays, and their relevant strengths and weaknesses. We also highlight drug resistance-associated genes in clinically important NTM species. Understanding the basis for different treatment outcomes with different causative species and drug-resistance mechanisms will eventually improve current treatment regimens and facilitate the development of better control measures for NTM diseases.
Collapse
Affiliation(s)
- Hee Jae Huh
- Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| | - Su-Young Kim
- Division of Pulmonary and Critical Care Medicine, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| | - Byung Woo Jhun
- Division of Pulmonary and Critical Care Medicine, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| | - Sung Jae Shin
- Department of Microbiology, Institute for Immunology and Immunological Disease, Brain Korea 21 PLUS Project for Medical Science, Yonsei University College of Medicine, Seoul, South Korea.
| | - Won-Jung Koh
- Division of Pulmonary and Critical Care Medicine, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea.
| |
Collapse
|
20
|
Performance of Vitek MS v3.0 for Identification of Mycobacterium Species from Patient Samples by Use of Automated Liquid Medium Systems. J Clin Microbiol 2018; 56:JCM.00219-18. [PMID: 29875193 DOI: 10.1128/jcm.00219-18] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2018] [Accepted: 05/31/2018] [Indexed: 12/27/2022] Open
Abstract
The accuracy and robustness of the Vitek MS v3.0 matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) system was evaluated by identifying mycobacteria from automated liquid-medium systems using patient samples. This is the first report to demonstrate that proteins within the liquid medium, its supplements, and decontamination reagents for nonsterile patient samples do not generate misidentification or false-positive results by use of the Vitek MS v3.0 system. Prior to testing with patient samples, a seeded-culture study was conducted to challenge the accuracy of the Vitek MS system at identifying mycobacteria from liquid medium by mimicking a clinical workflow. Seventy-seven Mycobacterium strains representing 21 species, seeded in simulated sputum, were decontaminated, inoculated into BacT/Alert MP liquid culture medium, incubated until positivity, and identified using the Vitek MS system. A total of 383 liquid cultures were tested, of which 379 (99%) were identified correctly to the species/complex/group level, 4 (1%) gave a "no-identification" result, and no misidentifications were observed. Following the simulated-sputum study, a total of 73 smear-positive liquid-medium cultures detected using BD BBL MGIT and VersaTREK Myco liquid media were identified by the Vitek MS system. Sixty-four cultures (87.7%) were correctly identified to the species/complex/group level; 7 (9.6%) resulted in no identification; and 2 (2.7%) were misidentified at the species level. These results indicate that the Vitek MS v3.0 system is an accurate tool for routine diagnostics of Mycobacterium species isolated from liquid cultures.
Collapse
|
21
|
Luo L, Cao W, Chen W, Zhang R, Jing L, Chen H, Yu F, Yue J. Evaluation of the VITEK MS knowledge base version 3.0 for the identification of clinically relevant Mycobacterium species. Emerg Microbes Infect 2018; 7:114. [PMID: 29973586 PMCID: PMC6031696 DOI: 10.1038/s41426-018-0120-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2017] [Revised: 05/18/2018] [Accepted: 05/29/2018] [Indexed: 11/09/2022]
Abstract
Different Mycobacterium spp. infections may indicate varied treatment regimens in the clinic. Thus, the species-level identification of Mycobacterium spp. is one of the most important tasks for a clinical microbiology laboratory. Although matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) has emerged as a rapid and accurate method for the identification of mycobacteria, this method lacks a comprehensive evaluation of the identification accuracy for clinically collected mycobacteria using VITEK MS Knowledge Base Version 3.0 (Ver 3.0). The objectives of the present study were to evaluate the identification performance of Mycobacterium spp. using Ver 3.0 and a sample processing kit for strain inactivation and protein extraction. Among the 507 Mycobacterium isolates, 46 isolates were M. tuberculosis, and 461 isolates were nontuberculous mycobacteria (NTM) (including 27 species: 17 species were slowly growing mycobacteria (SGM), and 10 species were rapidly growing mycobacteria (RGM)). The VITEK MS V3.0 library was used to correctly identify 476/507 (93.9%) isolates (425 isolates were correctly identified initially, and 51 more isolates were correctly identified on repeat), 23/507 (4.5%) isolates were unidentified, and 8/507 (1.6%) isolates were misidentified. In summary, we showed that Mycobacterium spp. can be adequately identified by Ver 3.0 in combination with the use of a standard sample processing kit.
Collapse
Affiliation(s)
- LiuLin Luo
- Department of Clinical Laboratory Medicine, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai, 200433, China
| | - Wen Cao
- Tongji University School of Medicine, Shanghai, 200092, China
| | - WeiWei Chen
- Tongji University School of Medicine, Shanghai, 200092, China
| | - RanRan Zhang
- Tongji University School of Medicine, Shanghai, 200092, China
| | - LinJie Jing
- Department of Clinical Laboratory Medicine, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai, 200433, China
| | - HuiPing Chen
- Department of Clinical Laboratory Medicine, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai, 200433, China
| | - FangYou Yu
- Department of Clinical Laboratory Medicine, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai, 200433, China.
| | - Jun Yue
- Department of Clinical Laboratory Medicine, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai, 200433, China.
| |
Collapse
|
22
|
Murugaiyan J, Lewin A, Kamal E, Bakuła Z, van Ingen J, Ulmann V, Unzaga Barañano MJ, Humięcka J, Safianowska A, Roesler UH, Jagielski T. MALDI Spectra Database for Rapid Discrimination and Subtyping of Mycobacterium kansasii. Front Microbiol 2018; 9:587. [PMID: 29670585 PMCID: PMC5893902 DOI: 10.3389/fmicb.2018.00587] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2018] [Accepted: 03/14/2018] [Indexed: 11/13/2022] Open
Abstract
Mycobacterium kansasii is an emerging non-tuberculous mycobacterial (NTM) pathogen capable of causing severe lung disease. Of the seven currently recognized M. kansasii genotypes (I-VII), genotypes I and II are most prevalent and have been associated with human disease, whereas the other five (III-VII) genotypes are predominantly of environmental origin and are believed to be non-pathogenic. Subtyping of M. kansasii serves as a valuable tool to guide clinicians in pursuing diagnosis and to initiate the proper timely treatment. Most of the previous rapid diagnostic tests for mycobacteria employing the matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) technology focused on species-level identification. The purpose of this study was to establish MALDI-TOF MS reference spectra database for discrimination of M. kansasii at the genotype level. A panel of 32 strains, representatives of M. kansasii genotypes I-VI were selected, whole cell proteins extracted and measured with MALDI-TOF MS. A unique main spectra (MSP) library was created using MALDI Biotyper Compass Explorer software. The spectra reproducibility was assessed by computing composite correlation index and MSPs cross-matching. One hundred clinical M. kansasii isolates used for testing of the database resulted in 90% identification at genus-level, 7% identification at species-level and 2% identification was below the threshold of log score value 1.7, of which all were correct at genotype level. One strain could not be identified. On the other hand, 37% of strains were identified at species level, 40% at genus level and 23% was not identified with the manufacturer's database. The MALDI-TOF MS was proven a rapid and robust tool to detect and differentiate between M. kansasii genotypes. It is concluded that MALDI-TOF MS has a potential to be incorporated into the routine diagnostic workflow of M. kansasii and possibly other NTM species.
Collapse
Affiliation(s)
- Jayaseelan Murugaiyan
- Centre for Infectious Medicine, Institute of Animal Hygiene and Environmental Health, Freie Universität Berlin, Berlin, Germany
| | - Astrid Lewin
- Division 16, Mycotic and Parasitic Agents and Mycobacteria, Robert Koch Institute, Berlin, Germany
| | - Elisabeth Kamal
- Division 16, Mycotic and Parasitic Agents and Mycobacteria, Robert Koch Institute, Berlin, Germany
| | - Zofia Bakuła
- Department of Applied Microbiology, Faculty of Biology, Institute of Microbiology, University of Warsaw, Warsaw, Poland
| | - Jakko van Ingen
- Department of Medical Microbiology, Radboud University Medical Center, Nijmegen, Netherlands
| | - Vit Ulmann
- Institute of Public Health, Ostrava, Czechia
| | | | - Joanna Humięcka
- Hospital for Infectious Diseases in Warsaw, Medical University of Warsaw, Warsaw, Poland
| | - Aleksandra Safianowska
- Department of Internal Medicine, Pulmonology, and Allergology, Medical University of Warsaw, Warsaw, Poland
| | - Uwe H Roesler
- Centre for Infectious Medicine, Institute of Animal Hygiene and Environmental Health, Freie Universität Berlin, Berlin, Germany
| | - Tomasz Jagielski
- Department of Applied Microbiology, Faculty of Biology, Institute of Microbiology, University of Warsaw, Warsaw, Poland
| |
Collapse
|
23
|
Accuracy of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Identification of Mycobacteria: a systematic review and meta-analysis. Sci Rep 2018. [PMID: 29515167 PMCID: PMC5841357 DOI: 10.1038/s41598-018-22642-w] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Mycobacterium species are a significant cause of morbidity and mortality worldwide. The present study was carried out to systematically evaluate the accuracy of Matrix-assisted laser desorption ionization-time of flight mass spectroscopy (MALDI-TOF MS) for the identification of clinical pathogenic mycobacteria. After a rigid selection process, 19 articles involving 2,593 mycobacteria isolates were included. The pooled result agreed with the reference method identification for 85% of the isolates to genus level, with 71% (95% CI of 69% to 72%) correct to the species level. The MALDI-TOF MS correctly identified 92% of the M.tuberculosis isolates (95% CI of 0.87 to 0.96), and 68% of M. bovisisolates (95% CI of 27% to 100%) to the species level. Mycobacterium tuberculosis complex in solid media with reference strains using augmented database showing more accurate identification. The identifying accuracy rate of bioMérieuxVitek MS was slight higher than Bruker MALDI Biotyper (75% vs 72%). However, opposite results were obtained in identifications of M. fortuitum, M. kansasii, M. marinum, and M. terrae with these two systems. In summary, our results demonstrate that application of MALDI-TOF MS in clinical pathogenic mycobacteria identification is less satisfactory to date. Increasing need for improvement is important especially at species level.
Collapse
|
24
|
Rapid identification of mycobacteria from positive MGIT broths of primary cultures by MALDI-TOF mass spectrometry. PLoS One 2018; 13:e0192291. [PMID: 29394275 PMCID: PMC5796708 DOI: 10.1371/journal.pone.0192291] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2017] [Accepted: 01/22/2018] [Indexed: 02/06/2023] Open
Abstract
Background Rapid identification of mycobacteria is important for timely treatment and the implementation of public health measures. The MGIT system ensures rapid detection of mycobacteria, but identification is usually delayed by days to weeks due to further subculture on solid medium. Matrix-assisted laser desorption time-of-flight mass spectrometry (MALDI-TOF MS) was demonstrated to effectively identify mycobacteria isolates subcultured from solid or liquid media. Reports of identification directly from MGIT broths of both sterile and non-sterile clinical specimens, omitting the subculture step, were limited and not satisfactory before. Our identification method dramatically shortened delay from detection to identification of mycobacteria. Methodology We assessed the performance of the Vitek MS IVD version 3.0 for direct identification of NTM and M.tuberculosis from primary MGIT cultures, and assessed two sample preparation methods. Results Direct identification of NTM from positive MGIT broths, using MALDI-TOF VITEK MS with IVD v.3.0, generated high rates of acceptable results reaching 96.4% (80/83), and up to 100% (83/83) for sample preparations including a 0.1% SDS washing step. The sensitivity of VITEK MS to identify M.tuberculosis from MGIT tubes was 58/72 (80.6%), when using immunochromatography (ICA) test as gold standard. A characteristic colony clumping, wool-like appearance was observed in 48, and all 58 (100%) were correctly identified as M.tuberculosis using MALDI-TOF. The detection rate of M.tuberculosis complex was low (10/24, 41.6%) in the 24 MGIT tubes that was polymicrobial. Our method significantly reduced both the reagent cost and turnaround time. Conclusions Based on a simplified protocol, we showed that MALDI-TOF MS can be used for rapid identification of NTM directly from primary MGIT cultures within the routine clinical laboratory workflow. However, we recommend an initial ICA test to screen for M.tuberculosis complex, due to a low identification rate of M. tuberculosis in the presence of polymicrobial cultures using MALDI-TOF.
Collapse
|
25
|
Grégory D, Chaudet H, Lagier JC, Raoult D. How mass spectrometric approaches applied to bacterial identification have revolutionized the study of human gut microbiota. Expert Rev Proteomics 2018; 15:217-229. [PMID: 29336192 DOI: 10.1080/14789450.2018.1429271] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
INTRODUCTION Describing the human hut gut microbiota is one the most exciting challenges of the 21st century. Currently, high-throughput sequencing methods are considered as the gold standard for this purpose, however, they suffer from several drawbacks, including their inability to detect minority populations. The advent of mass-spectrometric (MS) approaches to identify cultured bacteria in clinical microbiology enabled the creation of the culturomics approach, which aims to establish a comprehensive repertoire of cultured prokaryotes from human specimens using extensive culture conditions. Areas covered: This review first underlines how mass spectrometric approaches have revolutionized clinical microbiology. It then highlights the contribution of MS-based methods to culturomics studies, paying particular attention to the extension of the human gut microbiota repertoire through the discovery of new bacterial species. Expert commentary: MS-based approaches have enabled cultivation methods to be resuscitated to study the human gut microbiota and thus to fill in the blanks left by high-throughput sequencing methods in terms of culturing minority populations. Continued efforts to recover new taxa using culture methods, combined with their rapid implementation in genomic databases, would allow for an exhaustive analysis of the gut microbiota through the use of a comprehensive approach.
Collapse
Affiliation(s)
- Dubourg Grégory
- a Aix Marseille Université, Microbes Evolution Phylogeny and Infections (MEPHI), Assistance Publique - Hôpitaux de Marseille - IHU Méditerranée Infection , Marseille , France
| | - Hervé Chaudet
- a Aix Marseille Université, Microbes Evolution Phylogeny and Infections (MEPHI), Assistance Publique - Hôpitaux de Marseille - IHU Méditerranée Infection , Marseille , France
| | - Jean-Christophe Lagier
- a Aix Marseille Université, Microbes Evolution Phylogeny and Infections (MEPHI), Assistance Publique - Hôpitaux de Marseille - IHU Méditerranée Infection , Marseille , France
| | - Didier Raoult
- a Aix Marseille Université, Microbes Evolution Phylogeny and Infections (MEPHI), Assistance Publique - Hôpitaux de Marseille - IHU Méditerranée Infection , Marseille , France
| |
Collapse
|
26
|
New Technologies for the Diagnosis of Infection. DIAGNOSTIC PATHOLOGY OF INFECTIOUS DISEASE 2018. [PMCID: PMC7152403 DOI: 10.1016/b978-0-323-44585-6.00006-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
27
|
A novel liquid media mycobacteria extraction method for MALDI-TOF MS identification using VITEK® MS. J Microbiol Methods 2017; 144:128-133. [PMID: 29158151 DOI: 10.1016/j.mimet.2017.11.016] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2017] [Revised: 10/30/2017] [Accepted: 11/16/2017] [Indexed: 11/22/2022]
Abstract
A low-cost identification method that can be performed directly from a positive liquid medium culture is needed for the diagnosis of mycobacterial infections. Here, we describe a novel, cost-effective, and validated method that allows for direct and rapid identification of mycobacteria from a positive liquid culture using VITEK® MS with a total process duration under 45min. From a liquid mycobacteria culture a 3.0mL aliquot is removed 24-72h post positivity and centrifuged to create a pellet. After decanting, the tube is blotted dry, the pellet is re-suspended in 0.5mL of 70% ethanol and then transferred into a 2.0mL tube containing glass beads. Mycobacteria are disrupted mechanically followed by a 10min. incubation at room temperature to complete inactivation. Inactivated material is pelleted by centrifugation and then re-suspended in 10μL of 70% formic acid and 10μL of acetonitrile. After centrifugation, 1μL of supernatant (protein extract) is deposited onto target slide, allowed to dry, and then 1μL CHCA matrix is added. A seeded study was conducted to demonstrate the reliability of the method, a total of 251 culture samples obtained from automated culture systems (BacT/ALERT® MP bottles, BACTEC MGIT™ 960 tubes, and VersaTREK® Myco bottles), were tested and resulted in 98.8% correct identification. Reproducibility was shown by testing three organisms across three reagent lots, between four laboratory technicians, over the course of five days for three liquid media systems resulting in a total of 180 deposits with an overall correct identification of 98.9% with the remaining results giving no identification. Additional studies were performed including comparison of different mechanical disruption techniques, stability of frozen extracts, and stability of slide deposits to allow for flexibility in a routine clinical workflow. The described method proved to be safe while providing consistent and reproducible results for different species of mycobacteria and is compatible with the three most widely used liquid media medium detection systems.
Collapse
|
28
|
Manikandan M, Deenadayalan A, Vimala A, Gopal J, Chun S. Clinical MALDI mass spectrometry for tuberculosis diagnostics: Speculating the methodological blueprint and contemplating the obligation to improvise. Trends Analyt Chem 2017. [DOI: 10.1016/j.trac.2017.06.014] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
29
|
Sloan A, Wang G, Cheng K. Traditional approaches versus mass spectrometry in bacterial identification and typing. Clin Chim Acta 2017; 473:180-185. [PMID: 28866114 DOI: 10.1016/j.cca.2017.08.035] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2017] [Revised: 08/28/2017] [Accepted: 08/29/2017] [Indexed: 01/09/2023]
Abstract
Biochemical methods such as metabolite testing and serotyping are traditionally used in clinical microbiology laboratories to identify and categorize microorganisms. Due to the large variety of bacteria, identifying representative metabolites is tedious, while raising high-quality antisera or antibodies unique to specific biomarkers used in serotyping is very challenging, sometimes even impossible. Although serotyping is a certified approach for differentiating bacteria such as E. coli and Salmonella at the subspecies level, the method is tedious, laborious, and not practical during an infectious disease outbreak. Mass spectrometry (MS) platforms, especially matrix assisted laser desorption and ionization-time of flight mass spectrometry (MALDI-TOF-MS), have recently become popular in the field of bacterial identification due to their fast speed and low cost. In the past few years, we have used liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based approaches to solve various problems hindering serotyping and have overcome some insufficiencies of the MALDI-TOF-MS platform. The current article aims to review the characteristics, advantages, and disadvantages of MS-based platforms over traditional approaches in bacterial identification and categorization.
Collapse
Affiliation(s)
- Angela Sloan
- National Microbiology Laboratory, Public Health Agency of Canada, Winnipeg, Manitoba, Canada
| | - Gehua Wang
- National Microbiology Laboratory, Public Health Agency of Canada, Winnipeg, Manitoba, Canada
| | - Keding Cheng
- National Microbiology Laboratory, Public Health Agency of Canada, Winnipeg, Manitoba, Canada; Department of Human Anatomy and Cell Sciences, Faculty of Medicine, University of Manitoba, Winnipeg, Manitoba, Canada.
| |
Collapse
|
30
|
DMF-MALDI: droplet based microfluidic combined to MALDI-TOF for focused peptide detection. Sci Rep 2017; 7:6756. [PMID: 28754890 PMCID: PMC5533719 DOI: 10.1038/s41598-017-06660-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2017] [Accepted: 06/13/2017] [Indexed: 12/21/2022] Open
Abstract
We present an automated droplet microfluidic system (DMF) to generate monitored nanoliter aqueous droplets in oil and their deposition on a commercial stainless steel plate for MALDI-TOF analysis of peptides or protein digests. We demonstrate that DMF-MALDI combination focuses the analyte on the MALDI plate, increasing considerably the homogeneity of the dried material. This results in a 30times enhanced MALDI-TOF MS signal for a model peptide, allowing a significant improvement of the detection sensitivity limit (down to few tens of attomoles). Moreover, positive detection can be achieved from sub-nanomolar peptides solutions and better overall protein sequence coverages are obtained from few tens attomoles of protein digest. These results make DMF-MALDI a promising approach for the treatment of peptides samples as well as a key component for an integrated approach in the proteomic field.
Collapse
|
31
|
Yarbrough ML, Lainhart W, Burnham CAD. Identification of Nocardia, Streptomyces, and Tsukamurella using MALDI-TOF MS with the Bruker Biotyper. Diagn Microbiol Infect Dis 2017; 89:92-97. [PMID: 28811116 DOI: 10.1016/j.diagmicrobio.2017.06.019] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2017] [Revised: 05/16/2017] [Accepted: 06/20/2017] [Indexed: 11/19/2022]
Abstract
Nocardia species are the most commonly isolated aerobic actinomycetes from human clinical specimens. Our objective was to assess the identification of clinically relevant actinomycetes using the Bruker Biotyper MALDI-TOF system, including comparison of extraction methods, Biotyper library versions, score cutoffs, and media. Banked Streptomyces (n=10), Tsukamurella (n=2), and Nocardia isolates (n=60) were cultured and extracted using three methods: mycobacterial extraction, ethanol formic acid extraction, or direct on-target extraction. Following MALDI-TOF analysis, spectra were analyzed using versions 5 and 6 of the BDAL Biotyper library. Optimal species-level identifications for Nocardia were achieved using BDAL v6 at a score cutoff of ≥1.8 after direct extraction (49/60, 82%). Overall, the Biotyper platform with BDAL v6 accurately identified 12/16 species of Nocardia, demonstrating the utility of MALDI-TOF for identification of clinically relevant actinomycetes without the need for supplementation of the database.
Collapse
Affiliation(s)
- Melanie L Yarbrough
- Department of Pathology and Immunology, Washington University School of Medicine, 660 S. Euclid Ave, Campus Box 8118, Saint Louis, MO, 63110.
| | - William Lainhart
- Department of Pathology and Immunology, Washington University School of Medicine, 660 S. Euclid Ave, Campus Box 8118, Saint Louis, MO, 63110
| | - Carey-Ann D Burnham
- Department of Pathology and Immunology, Washington University School of Medicine, 660 S. Euclid Ave, Campus Box 8118, Saint Louis, MO, 63110
| |
Collapse
|
32
|
Kollef MH, Burnham CAD. Ventilator-Associated Pneumonia: The Role of Emerging Diagnostic Technologies. Semin Respir Crit Care Med 2017; 38:253-263. [PMID: 28578550 PMCID: PMC7117076 DOI: 10.1055/s-0037-1599224] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Antibiotic resistance has emerged as a key determinant of outcome in patients with serious infections along with the virulence of the underlying pathogen. Within the intensive care unit (ICU) setting, ventilator-associated pneumonia (VAP) is a common nosocomial infection that is frequently caused by multidrug-resistant bacteria. Antimicrobial resistance is a growing challenge in the care of critically ill patients. Escalating rates of antibiotic resistance add substantially to the morbidity, mortality, and cost related to infection in the ICU. Both gram-positive organisms, such as methicillin-resistant Staphylococcus aureus and vancomycin-intermediate S. aureus, and gram-negative bacteria, including Pseudomonas aeruginosa, Acinetobacter species, carbapenem-resistant Enterobacteriaceae, such as the Klebsiella pneumoniae carbapenemase-producing bacteria, and extended spectrum β-lactamase organisms, have contributed to the escalating rates of resistance seen in VAP and other nosocomial infections. The rising rates of antimicrobial resistance have led to the routine empiric administration of broad-spectrum antibiotics even when bacterial infection is not documented. Moreover, there are several new broader-spectrum antibiotics that have recently become available and others scheduled for approval in the near future. The challenge to ICU clinicians is how to most effectively utilize these agents to maximize patient benefits while minimizing further emergence of resistance. Use of rapid diagnostics may hold the key for achieving this important balance. There is an urgent need for integrating the administration of new and existing antibiotics with the emerging rapid diagnostic technologies in a way that is both cost-effective and sustainable for the long run.
Collapse
Affiliation(s)
- Marin H Kollef
- Division of Pulmonary and Critical Care Medicine, Washington University School of Medicine, St. Louis, Missouri
| | - Carey-Ann D Burnham
- Department of Pathology and Immunology, Washington University School of Medicine, St. Louis, Missouri
| |
Collapse
|
33
|
Turvey ME, Weiland F, Keller EJ, Hoffmann P. The changing face of microbial quality control practices in the brewing industry: Introducing mass spectrometry proteomic fingerprinting for microbial identification. JOURNAL OF THE INSTITUTE OF BREWING 2017. [DOI: 10.1002/jib.428] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- M. E. Turvey
- Adelaide Proteomics Centre; The University of Adelaide; Australia
- Institute of Photonics and Advanced Sensing; Australia
- Singapore-MIT Alliance for Research and Technology Centre; Singapore
| | - F. Weiland
- Adelaide Proteomics Centre; The University of Adelaide; Australia
- Institute of Photonics and Advanced Sensing; Australia
| | - E. J. Keller
- Adelaide Proteomics Centre; The University of Adelaide; Australia
- Institute of Photonics and Advanced Sensing; Australia
| | - P. Hoffmann
- Adelaide Proteomics Centre; The University of Adelaide; Australia
- Institute of Photonics and Advanced Sensing; Australia
| |
Collapse
|
34
|
Comparison of Saramis 4.12 and IVD 3.0 Vitek MS Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Identification of Mycobacteria from Solid and Liquid Culture Media. J Clin Microbiol 2017; 55:2045-2054. [PMID: 28424252 DOI: 10.1128/jcm.00006-17] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2017] [Accepted: 04/04/2017] [Indexed: 01/25/2023] Open
Abstract
During the last decade, many investigators have studied matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) for identification of mycobacteria. Diverse and contradictory results indicated that optimal level for routine testing has not been reached yet. This work aimed to assess Vitek MS through two distinct versions, Saramis v4.12 RUO and the IVD v3.0, under conditions close to routine laboratory practice. Overall, 111 mycobacterial isolates were subjected to protein extraction and same spectra were matched against both databases. The IVD v3.0 database proved to be superior to Saramis v4.12 and its identification rates remarkably increased, from 67% to 94% for isolates grown on Middlebrook 7H10 solid medium and from 62% to 91% for isolates grown on mycobacterial growth indicator tube (MGIT) liquid medium. With this new version, IVD v3.0, MALDI-TOF MS might be integrated into routine clinical diagnostics, although molecular techniques remain mandatory in some cases.
Collapse
|
35
|
Abstract
ABSTRACT
Rapidly growing mycobacteria (RGM) compose approximately one-half of the currently validated mycobacterial species and are divided into six major groups, including the
Mycobacterium fortuitum
group,
M. chelonae/M. abscessus
complex,
M. smegmatis
group,
M. mucogenicum
group,
M. mageritense
/
M. wolinskyi
, and the pigmented RGM. This review discusses each group and highlights the major types of infections associated with each group. Additionally, phenotypic and molecular laboratory identification methods, including gene sequencing, mass spectrometry, and the newly emerging whole-genome sequencing, are detailed, along with a discussion of the current antimicrobial susceptibility methods and patterns of the most common pathogenic species.
Collapse
|
36
|
Sandalakis V, Goniotakis I, Vranakis I, Chochlakis D, Psaroulaki A. Use of MALDI-TOF mass spectrometry in the battle against bacterial infectious diseases: recent achievements and future perspectives. Expert Rev Proteomics 2017; 14:253-267. [PMID: 28092721 DOI: 10.1080/14789450.2017.1282825] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
INTRODUCTION Advancements in microbial identification occur increasingly faster as more laboratories explore, refine and extend the use of mass spectrometry in the field of microbiology. Areas covered: This review covers the latest knowledge found in the literature for quick identification of various classes of bacterial pathogens known to cause human infection by the use of MALDI-TOF MS technology. Except for identification of bacterial strains, more researchers try to 'battle time' in favor of the patient. These novel approaches to identify bacteria directly from clinical samples and even determine antibiotic resistance are extensively revised and discussed. Expert commentary: Mass spectrometry is the future of bacterial identification and creates a new era in modern microbiology. Its incorporation in routine practice seems to be not too far, providing a valuable alternative, especially in terms of time, to conventional techniques. If the technology further advances, quick bacterial identification and probable identification of common antibiotic resistance might guide patient decision-making regarding bacterial infectious diseases in the near future.
Collapse
Affiliation(s)
- Vassilios Sandalakis
- a Laboratory of Clinical Bacteriology, Parasitology, Zoonoses and Geographical Medicine, School of Medicine , University of Crete , Heraklion , Greece
| | - Ioannis Goniotakis
- a Laboratory of Clinical Bacteriology, Parasitology, Zoonoses and Geographical Medicine, School of Medicine , University of Crete , Heraklion , Greece
| | - Iosif Vranakis
- a Laboratory of Clinical Bacteriology, Parasitology, Zoonoses and Geographical Medicine, School of Medicine , University of Crete , Heraklion , Greece
| | - Dimosthenis Chochlakis
- a Laboratory of Clinical Bacteriology, Parasitology, Zoonoses and Geographical Medicine, School of Medicine , University of Crete , Heraklion , Greece
| | - Anna Psaroulaki
- a Laboratory of Clinical Bacteriology, Parasitology, Zoonoses and Geographical Medicine, School of Medicine , University of Crete , Heraklion , Greece
| |
Collapse
|
37
|
Siller-Ruiz M, Hernández-Egido S, Sánchez-Juanes F, González-Buitrago JM, Muñoz-Bellido JL. Fast methods of fungal and bacterial identification. MALDI-TOF mass spectrometry, chromogenic media. Enferm Infecc Microbiol Clin 2017; 35:303-313. [PMID: 28108122 DOI: 10.1016/j.eimc.2016.12.010] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2016] [Accepted: 12/20/2016] [Indexed: 11/16/2022]
Abstract
MALDI-TOF mass spectrometry is now a routine resource in Clinical Microbiology, because of its speed and reliability in the identification of microorganisms. Its performance in the identification of bacteria and yeasts is perfectly contrasted. The identification of mycobacteria and moulds is more complex, due to the heterogeneity of spectra within each species. The methodology is somewhat more complex, and expanding the size of species libraries, and the number of spectra of each species, will be crucial to achieve greater efficiency. Direct identification from blood cultures has been implemented, since its contribution to the management of severe patients is evident, but its application to other samples is more complex. Chromogenic media have also contributed to the rapid diagnosis in both bacteria and yeast, since they accelerate the diagnosis, facilitate the detection of mixed cultures and allow rapid diagnosis of resistant species.
Collapse
Affiliation(s)
- María Siller-Ruiz
- Instituto de Investigación Biomédica de Salamanca (IBSAL), Complejo Asistencial Universitario de Salamanca, Universidad de Salamanca, CSIC, Salamanca, España
| | - Sara Hernández-Egido
- Instituto de Investigación Biomédica de Salamanca (IBSAL), Complejo Asistencial Universitario de Salamanca, Universidad de Salamanca, CSIC, Salamanca, España
| | - Fernando Sánchez-Juanes
- Instituto de Investigación Biomédica de Salamanca (IBSAL), Complejo Asistencial Universitario de Salamanca, Universidad de Salamanca, CSIC, Salamanca, España
| | - José Manuel González-Buitrago
- Instituto de Investigación Biomédica de Salamanca (IBSAL), Complejo Asistencial Universitario de Salamanca, Universidad de Salamanca, CSIC, Salamanca, España; Servicio de Bioquímica Clínica, Complejo Asistencial Universitario de Salamanca, Salamanca, España; Departamento de Bioquímica y Biología Molecular, Universidad de Salamanca, Salamanca, España
| | - Juan Luis Muñoz-Bellido
- Instituto de Investigación Biomédica de Salamanca (IBSAL), Complejo Asistencial Universitario de Salamanca, Universidad de Salamanca, CSIC, Salamanca, España; Servicio de Microbiología, Complejo Asistencial Universitario de Salamanca, Salamanca, España; Departamento de Ciencias Biomédicas y del Diagnóstico, Universidad de Salamanca, Salamanca, España.
| |
Collapse
|
38
|
Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Combined Species Identification and Drug Sensitivity Testing in Mycobacteria. J Clin Microbiol 2016; 55:624-634. [PMID: 28003422 DOI: 10.1128/jcm.02089-16] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2016] [Accepted: 12/02/2016] [Indexed: 01/22/2023] Open
Abstract
Species identification and drug susceptibility testing (DST) of mycobacteria are important yet complex processes traditionally reserved for reference laboratories. Recent technical improvements in matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has started to facilitate routine mycobacterial identifications in clinical laboratories. In this paper, we investigate the possibility of performing phenotypic MALDI-based DST in mycobacteriology using the recently described MALDI Biotyper antibiotic susceptibility test rapid assay (MBT-ASTRA). We randomly selected 72 clinical Mycobacterium tuberculosis and nontuberculous mycobacterial (NTM) strains, subjected them to MBT-ASTRA methodology, and compared its results to current gold-standard methods. Drug susceptibility was tested for rifampin, isoniazid, linezolid, and ethambutol (M. tuberculosis, n = 39), and clarithromycin and rifabutin (NTM, n = 33). Combined species identification was performed using the Biotyper Mycobacteria Library 4.0. Mycobacterium-specific MBT-ASTRA parameters were derived (calculation window, m/z 5,000 to 13,000, area under the curve [AUC] of >0.015, relative growth [RG] of <0.5; see the text for details). Using these settings, MBT-ASTRA analyses returned 175/177 M. tuberculosis and 65/66 NTM drug resistance profiles which corresponded to standard testing results. Turnaround times were not significantly different in M. tuberculosis testing, but the MBT-ASTRA method delivered on average a week faster than routine DST in NTM. Databases searches returned 90.4% correct species-level identifications, which increased to 98.6% when score thresholds were lowered to 1.65. In conclusion, the MBT-ASTRA technology holds promise to facilitate and fasten mycobacterial DST and to combine it directly with high-confidence species-level identifications. Given the ease of interpretation, its application in NTM typing might be the first in finding its way to current diagnostic workflows. However, further validations and automation are required before routine implementation can be envisioned.
Collapse
|
39
|
Abstract
Although mass spectrometry has been used clinically for decades, the advent of immunoassay technology moved the clinical laboratory to more labor saving automated platforms requiring little if any sample preparation. It became clear, however, that immunoassays lacked sufficient sensitivity and specificity necessary for measurement of certain analytes or for measurement of analytes in specific patient populations. This limitation prompted clinical laboratories to revisit mass spectrometry which could additionally be used to develop assays for which there was no commercial source. In this chapter, the clinical applications of mass spectrometry in therapeutic drug monitoring, toxicology, and steroid hormone analysis will be reviewed. Technologic advances and new clinical applications will also be discussed.
Collapse
Affiliation(s)
- D French
- University of California San Francisco, San Francisco, CA, United States.
| |
Collapse
|
40
|
Emerging and Future Applications of Matrix-Assisted Laser Desorption Ionization Time-of-Flight (MALDI-TOF) Mass Spectrometry in the Clinical Microbiology Laboratory. J Mol Diagn 2016; 18:789-802. [DOI: 10.1016/j.jmoldx.2016.07.007] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2015] [Revised: 06/29/2016] [Accepted: 07/21/2016] [Indexed: 12/17/2022] Open
|
41
|
Park JS, Choi SH, Hwang SM, Hong YJ, Kim TS, Park KU, Song J, Kim EC. The impact of protein extraction protocols on the performance of currently available MALDI-TOF mass spectrometry for identification of mycobacterial clinical isolates cultured in liquid media. Clin Chim Acta 2016; 460:190-5. [DOI: 10.1016/j.cca.2016.06.039] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2016] [Revised: 06/24/2016] [Accepted: 06/29/2016] [Indexed: 11/15/2022]
|
42
|
Karger A. Current developments to use linear MALDI-TOF spectra for the identification and typing of bacteria and the characterization of other cells/organisms related to infectious diseases. Proteomics Clin Appl 2016; 10:982-993. [PMID: 27400768 DOI: 10.1002/prca.201600038] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2016] [Revised: 05/30/2016] [Accepted: 07/07/2016] [Indexed: 12/21/2022]
Abstract
Within the past few years identification of bacteria by MALDI-TOF MS has become a standard technique in bacteriological laboratories for good reasons. MALDI-TOF MS identification is rapid, robust, automatable, and the per-sample costs are low. Yet, the spectra are very informative and the reliable identification of bacterial species is usually possible. Recently, new MS-based approaches for the identification of bacteria are emerging that are based on the detailed analysis of the bacterial proteome by high-resolution MS. These "proteotyping" approaches are highly discriminative and outperform MALDI-TOF MS-based identification in terms of specificity, but require a laborious proteomic workflow and far more expertise and sophisticated instrumentation than identification on basis of MALDI-TOF MS spectra, which can be obtained with relative simple and uncostly linear MALDI-TOF mass spectrometers. Thus MALDI-TOF MS identification of bacteria remains an attractive option for routine diagnostics. Additionally, MALDI-TOF MS identification protocols have been extended and improved in many respects making linear MALDI-TOF MS a versatile tool that can be useful beyond the identification of a bacterial species, e.g. for the characterization of leucocytes and arthropod vectors of infectious diseases. This review focuses on such improvements and extensions of the typical MALDI-TOF MS workflow in the field of infectious diseases.
Collapse
Affiliation(s)
- Axel Karger
- Institute of Molecular Virology and Cell Biology, Friedrich-Loeffler-Institut, , Federal Research Institute for Animal Health Südufer, Greifswald-Insel Riems, Germany.
| |
Collapse
|
43
|
Evaluation of the Vitek MS Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry System for Identification of Clinically Relevant Filamentous Fungi. J Clin Microbiol 2016; 54:2068-73. [PMID: 27225405 DOI: 10.1128/jcm.00825-16] [Citation(s) in RCA: 52] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2016] [Accepted: 05/19/2016] [Indexed: 12/22/2022] Open
Abstract
Invasive fungal infections have a high rate of morbidity and mortality, and accurate identification is necessary to guide appropriate antifungal therapy. With the increasing incidence of invasive disease attributed to filamentous fungi, rapid and accurate species-level identification of these pathogens is necessary. Traditional methods for identification of filamentous fungi can be slow and may lack resolution. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has emerged as a rapid and accurate method for identification of bacteria and yeasts, but a paucity of data exists on the performance characteristics of this method for identification of filamentous fungi. The objective of our study was to evaluate the accuracy of the Vitek MS for mold identification. A total of 319 mold isolates representing 43 genera recovered from clinical specimens were evaluated. Of these isolates, 213 (66.8%) were correctly identified using the Vitek MS Knowledge Base, version 3.0 database. When a modified SARAMIS (Spectral Archive and Microbial Identification System) database was used to augment the version 3.0 Knowledge Base, 245 (76.8%) isolates were correctly identified. Unidentified isolates were subcultured for repeat testing; 71/319 (22.3%) remained unidentified. Of the unidentified isolates, 69 were not in the database. Only 3 (0.9%) isolates were misidentified by MALDI-TOF MS (including Aspergillus amoenus [n = 2] and Aspergillus calidoustus [n = 1]) although 10 (3.1%) of the original phenotypic identifications were not correct. In addition, this methodology was able to accurately identify 133/144 (93.6%) Aspergillus sp. isolates to the species level. MALDI-TOF MS has the potential to expedite mold identification, and misidentifications are rare.
Collapse
|
44
|
Multicenter Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Study for Identification of Clinically Relevant Nocardia spp. J Clin Microbiol 2016; 54:1251-8. [PMID: 26912758 DOI: 10.1128/jcm.02942-15] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2015] [Accepted: 02/03/2016] [Indexed: 12/16/2022] Open
Abstract
This multicenter study analyzed Nocardia spp., including extraction, spectral acquisition, Bruker matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) identification, and score interpretation, using three Nocardia libraries, the Bruker, National Institutes of Health (NIH), and The Ohio State University (OSU) libraries, and compared the results obtained by each center. A standardized study protocol, 150 Nocardia isolates, and NIH and OSU Nocardia MALDI-TOF MS libraries were distributed to three centers. Following standardized culture, extraction, and MALDI-TOF MS analysis, isolates were identified using score cutoffs of ≥2.0 for species/species complex-level identification and ≥1.8 for genus-level identification. Isolates yielding a score of <2.0 underwent a single repeat extraction and analysis. The overall score range for all centers was 1.3 to 2.7 (average, 2.2 ± 0.3), with common species generally producing higher average scores than less common ones. Score categorization and isolate identification demonstrated 86% agreement between centers; 118 of 150 isolates were correctly identified to the species/species complex level by all centers. Nine strains (6.0%) were not identified by any center, and six (4.0%) of these were uncommon species with limited library representation. A categorical score discrepancy among centers occurred for 21 isolates (14.0%). There was an overall benefit of 21.2% from repeat extraction of low-scoring isolates and a center-dependent benefit for duplicate spotting (range, 2 to 8.7%). Finally, supplementation of the Bruker Nocardia MALDI-TOF MS library with both the OSU and NIH libraries increased the genus-level and species-level identification by 18.2% and 36.9%, respectively. Overall, this study demonstrates the ability of diverse clinical microbiology laboratories to utilize MALDI-TOF MS for the rapid identification of clinically relevant Nocardia spp. and to implement MALDI-TOF MS libraries developed by single laboratories across institutions.
Collapse
|
45
|
Cheng K, Chui H, Domish L, Hernandez D, Wang G. Recent development of mass spectrometry and proteomics applications in identification and typing of bacteria. Proteomics Clin Appl 2016; 10:346-57. [PMID: 26751976 PMCID: PMC5067657 DOI: 10.1002/prca.201500086] [Citation(s) in RCA: 67] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2015] [Revised: 12/11/2015] [Accepted: 01/04/2016] [Indexed: 11/29/2022]
Abstract
Identification and typing of bacteria occupy a large fraction of time and work in clinical microbiology laboratories. With the certification of some MS platforms in recent years, more applications and tests of MS‐based diagnosis methods for bacteria identification and typing have been created, not only on well‐accepted MALDI‐TOF‐MS‐based fingerprint matches, but also on solving the insufficiencies of MALDI‐TOF‐MS‐based platforms and advancing the technology to areas such as targeted MS identification and typing of bacteria, bacterial toxin identification, antibiotics susceptibility/resistance tests, and MS‐based diagnostic method development on unique bacteria such as Clostridium and Mycobacteria. This review summarizes the recent development in MS platforms and applications in bacteria identification and typing of common pathogenic bacteria.
Collapse
Affiliation(s)
- Keding Cheng
- National Microbiology Laboratory, Public Health Agency of Canada, Winnipeg, Manitoba, Canada.,Department of Human Anatomy and Cell Sciences, Faculty of Medicine, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Huixia Chui
- Henan Centre of Disease Control and Prevention, Henan Province, P. R. China
| | - Larissa Domish
- National Microbiology Laboratory, Public Health Agency of Canada, Winnipeg, Manitoba, Canada
| | - Drexler Hernandez
- National Microbiology Laboratory, Public Health Agency of Canada, Winnipeg, Manitoba, Canada
| | - Gehua Wang
- National Microbiology Laboratory, Public Health Agency of Canada, Winnipeg, Manitoba, Canada
| |
Collapse
|
46
|
Mareković I, Bošnjak Z, Jakopović M, Boras Z, Janković M, Popović-Grle S. Evaluation of Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry in Identification of Nontuberculous Mycobacteria. Chemotherapy 2016; 61:167-70. [DOI: 10.1159/000442517] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2015] [Accepted: 11/16/2015] [Indexed: 11/19/2022]
Abstract
Background/Aims: Species-level identification of nontuberculous mycobacteria (NTM) is important in making decisions about the necessity and choice of antimicrobial treatment. The reason is predictable clinical significance and the susceptibility profile of specific NTM species. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is recognized as a diagnostic tool for routine identification of bacteria and yeasts in the clinical laboratory based on protein fingerprint analysis. The aim of the study was to evaluate MALDI-TOF MS in the identification of NTM. Methods: A total of 25 NTM isolates from liquid cultures were identified with both polymerase chain reaction (PCR)-based hybridization assay and MALDI-TOF MS at the University Hospital Center Zagreb. Results: PCR-based hybridization assay identified 96% (24/25) and MALDI-TOF MS 80% (20/25) of tested NTM isolates. Five isolates with no reliable MALDI-TOF MS identification belonged to the Mycobacterium avium-intracellulare complex. Seventy percent (14/20) of NTM isolates successfully identified with MALDI-TOF MS had a score higher than 2.0, indicating reliable species identification. Conclusion: MALDI-TOF MS is a promising tool for the identification of NTM. With a further improvement of the protein extraction protocol, especially regarding the M. avium-intracellulare complex, MALDI-TOF MS could be an additional standard method for identification of NTM.
Collapse
|
47
|
Kehrmann J, Schoerding AK, Murali R, Wessel S, Koehling HL, Mosel F, Buer J. Performance of Vitek MS in identifying nontuberculous mycobacteria from MGIT liquid medium and Lowenstein–Jensen solid medium. Diagn Microbiol Infect Dis 2016; 84:43-47. [DOI: 10.1016/j.diagmicrobio.2015.10.007] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2015] [Revised: 09/30/2015] [Accepted: 10/04/2015] [Indexed: 10/22/2022]
|
48
|
Shih CJ, Chen SC, Weng CY, Lai MC, Yang YL. Rapid identification of haloarchaea and methanoarchaea using the matrix assisted laser desorption/ionization time-of-flight mass spectrometry. Sci Rep 2015; 5:16326. [PMID: 26541644 PMCID: PMC4635381 DOI: 10.1038/srep16326] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2015] [Accepted: 10/13/2015] [Indexed: 12/23/2022] Open
Abstract
The aim of this study was to classify certain environmental haloarchaea and methanoarchaea using matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS), and to expand the archaeal mass spectral database. A total of 69 archaea were collected including type strains and samples isolated locally from different environments. For extraction of the haloarchaeal total cell peptides/proteins, a simple method of acetonitrile extraction was developed. Cluster analysis conducted with the MALDI-TOF MS data overcame the high divergence in intragenomic 16S rRNA sequences in haloarchaea and clearly distinguished Methanohalophilus mahii from M. portucalensis. Putative biomarkers that can distinguish several particular archaeal genera were also assigned. In conclusion, this study expands the mass spectral database of peptide/protein fingerprints from bacteria and fungi to the archaea domain and provides a rapid identification platform for environmental archaeal samples.
Collapse
Affiliation(s)
- Chao-Jen Shih
- Agricultural Biotechnology Research Center, Academia Sinica, Taipei, Taiwan
| | - Sheng-Chung Chen
- Department of Life Sciences, National Chung Hsing University, Taichung, Taiwan
| | - Chieh-Yin Weng
- Department of Life Sciences, National Chung Hsing University, Taichung, Taiwan
| | - Mei-Chin Lai
- Department of Life Sciences, National Chung Hsing University, Taichung, Taiwan;,Agricultural Biotechnology Center, National Chung Hsing University, Taichung, Taiwan.,Ph.D. Program in Microbial Genomics, National Chung Hsing University and Academia Sinica, Taiwan
| | - Yu-Liang Yang
- Agricultural Biotechnology Research Center, Academia Sinica, Taipei, Taiwan.,Ph.D. Program in Microbial Genomics, National Chung Hsing University and Academia Sinica, Taiwan
| |
Collapse
|
49
|
Brown-Pigmented Mycobacterium mageritense as a Cause of Prosthetic Valve Endocarditis and Bloodstream Infection. J Clin Microbiol 2015; 53:2777-80. [PMID: 26063854 DOI: 10.1128/jcm.01041-15] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2015] [Accepted: 06/03/2015] [Indexed: 02/03/2023] Open
Abstract
Mycobacterium spp. are a rare cause of endocarditis. Herein, we describe a case of Mycobacterium mageritense prosthetic valve endocarditis. This organism produced an unusual brown pigment on solid media. Cultures of valve tissue for acid-fast bacilli might be considered in some cases of apparently culture-negative prosthetic valve endocarditis.
Collapse
|