1
|
Abdelazim AH, Abdelazim MH, Algarni MA, Alsulami FT, Alnemari RM, Alharbi A, Abduljabbar MH, Almalki AH. Paper based analytical devices for ions determination in nasal secretions demonstrating association with olfactory function. Anal Biochem 2024; 694:115614. [PMID: 38996899 DOI: 10.1016/j.ab.2024.115614] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2024] [Revised: 07/08/2024] [Accepted: 07/10/2024] [Indexed: 07/14/2024]
Abstract
Nasal ions environment plays a crucial role in maintaining nasal physiology and supports olfactory transmission. Addressing the limited research on nasal ion levels and their association with olfactory function, paper-based sensors were developed for determination of sodium, potassium, calcium and chloride in the nasal mucus of healthy volunteers and patients with olfactory dysfunction. Multi-walled carbon nanotubes and carbon quantum dots from beetroot were incorporated into paper substrate where sensors were designed with ion association complexes for sodium, potassium, calcium and chloride enhancing the recognition sensing capabilities. The sensors composition was optimized, including ion-exchange materials and plasticizers, to enhance sensitivity and selectivity. The performance of the sensors is evaluated based on Nernstian slope, dynamic range, detection limit and response time. Selectivity of the sensors was tested and the results demonstrated high selectivity for the target ions. The sensors were successfully determined sodium, potassium, calcium and chloride levels in nasal mucus of healthy volunteers and patients with olfactory dysfunction. The results revealed elevated calcium levels in patients with olfactory dysfunction, highlighting associated diagnostic implications. This suggests that the proposed sensors could serve as a diagnostic tool for olfactory evaluation, particularly in resource-constrained settings where access to advanced diagnostic tools is limited.
Collapse
Affiliation(s)
- Ahmed H Abdelazim
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Al-Azhar University, Cairo, 11751, Egypt.
| | - Mohamed H Abdelazim
- Department of Otolaryngology, Faculty of Medicine, Al-Azhar University, Damietta, 34518, Egypt
| | - Majed A Algarni
- Department of Clinical Pharmacy, College of Pharmacy, Taif University, P.O. Box 11099, Taif, 21944, Saudi Arabia
| | - Fahad T Alsulami
- Department of Clinical Pharmacy, College of Pharmacy, Taif University, P.O. Box 11099, Taif, 21944, Saudi Arabia
| | - Reem M Alnemari
- Department of Pharmaceutics and Pharmaceutical Technology, College of Pharmacy, Taif University, P.O. Box 11099, Taif, 21944, Saudi Arabia
| | - Adnan Alharbi
- Pharmaceutical Practices Department, College of Pharmacy, Umm Al-Qura University, Makkah, Saudi Arabia
| | - Maram H Abduljabbar
- Department of Pharmacology and Toxicology, College of Pharmacy, Taif University, P.O. Box 11099, Taif, 21944, Saudi Arabia
| | - Atiah H Almalki
- Department of Pharmaceutical Chemistry, College of Pharmacy, Taif University, P.O. Box 11099, Taif, 21944, Saudi Arabia; Addiction and Neuroscience Research Unit, Health Science Campus, Taif University, P.O. Box 11099, Taif, 21944, Saudi Arabia
| |
Collapse
|
2
|
Makram TS, Eid SM, Abu-Dahab M, AbouGhaly MHH, Elnahas OS. Formulation of Saxagliptin Oral Films: Optimization, Physicochemical Characterization, In-Vivo Assessment, and In-Vitro Real-Time Release Monitoring via a Novel Polyaniline Nanoparticles-Based Solid-Contact Screen Printed Ion-Selective Electrode. AAPS PharmSciTech 2024; 25:116. [PMID: 38769223 DOI: 10.1208/s12249-024-02828-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Accepted: 05/01/2024] [Indexed: 05/22/2024] Open
Abstract
Oral dispersible films have received broad interest due to fast drug absorption and no first-path metabolism, leading to high bioavailability and better patient compliance. Saxagliptin (SXG) is an antidiabetic drug that undergoes first-path metabolism, resulting in a less active metabolite, so the development of SXG oral dispersible films (SXG-ODFs) improves SXG bioavailability. The formula optimisation included a response surface experimental design and the impact of three formulation factors, the type and concentration of polymer and plasticiser concentration on in-vitro disintegration time and folding endurance. Two optimised SXG-ODFs prepared using either polyvinyl alcohol (PVA) or hydroxypropyl methylcellulose were investigated. SXG-ODFs prepared with PVA demonstrated a superior rapid disintegration time, ranging from 17 to 890 s, with the fastest disintegration time recorded at 17 s. These short durations can be attributed to the hydrophilic nature of PVA, facilitating rapid hydration and disintegration upon contact with saliva. Additionally, PVA-based films displayed remarkable folding endurance, surpassing 200 folds without rupture, indicating flexibility and stability. The high tensile strength of PVA-based films further underscores their robust mechanical properties, with tensile strength values reaching up to 4.53 MPa. SXG exhibits a UV absorption wavelength of around 212 nm, posing challenges for traditional quantitative spectrophotometric analysis, so a polyaniline nanoparticles-based solid-contact screen-printed ion-selective electrode (SP-ISE) was employed for the determination of SXG release profile effectively in comparison to HPLC. SP-ISE showed a better real-time release profile of SXG-ODFs, and the optimised formula showed lower blood glucose levels than commercial tablets.
Collapse
Affiliation(s)
- Tarek S Makram
- Pharmaceutics and Industrial Pharmacy Department, Faculty of Pharmacy, October 6 University, 6 October City, Giza, Egypt
| | - Sherif M Eid
- Analytical Chemistry Department, Faculty of Pharmacy, October 6 University, 6 October City, Giza, Egypt.
| | - Mohamed Abu-Dahab
- Pharmaceutics and Industrial Pharmacy Department, Faculty of Pharmacy, October 6 University, 6 October City, Giza, Egypt
| | - Mohamed H H AbouGhaly
- Department of Pharmaceutics and Industrial Pharmacy, Faculty of Pharmacy, Cairo University, Cairo, 11562, Egypt
| | - Osama S Elnahas
- Pharmaceutics and Industrial Pharmacy Department, Faculty of Pharmacy, October 6 University, 6 October City, Giza, Egypt
| |
Collapse
|
3
|
Bao H, Ye J, Zhang Y. A Multichannel Screen-Printed Carbon Electrode Based on Fluorinated Poly(3-octylthiophene-2,5-diyl) and Purified Mesoporous Carbon Black Simultaneously Detects Na +, K +, Ca 2+, and NO 2. ACS OMEGA 2024; 9:18238-18248. [PMID: 38680364 PMCID: PMC11044230 DOI: 10.1021/acsomega.3c10471] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 03/29/2024] [Accepted: 04/03/2024] [Indexed: 05/01/2024]
Abstract
Preparation of nanocomposites based on fluorinated poly(3-octylthiophene-2,5-diyl) (POTF) and purified mesoporous carbon black (PMCB) as the solid-contact layer of a screen-printed carbon electrode (SPCE) is proposed. POTF is used as a dispersant for PMCB. The obtained nanocomposites possess unique characteristics including high conductivity, capacitance, and stability. The SPCE based on POTF and PMCB is characterized by electrochemical impedance spectroscopy and chronopotentiometry, demonstrating simultaneous detection of Na+, K+, Ca2+, and NO2- ions with detection limits of 10-6.5, 10-6.4, 10-6.7, and 10-6.3 M, respectively. Water layer and anti-interference tests revealed that the electrode has high hydrophobicity, and the static contact angle is >140°. The electrode shows excellent selectivity, repeatability, reproducibility, and stability and is not easily affected by light, O2, or CO2.
Collapse
Affiliation(s)
- Hui Bao
- College
of Information Science and Engineering, Henan University of Technology, Zhengzhou, Henan 450001, China
| | - Jin Ye
- College
of Information Science and Engineering, Henan University of Technology, Zhengzhou, Henan 450001, China
- Academy
of National Food and Strategic Reserves Administration, Beijing 102600, China
| | - Yuan Zhang
- College
of Information Science and Engineering, Henan University of Technology, Zhengzhou, Henan 450001, China
| |
Collapse
|
4
|
Bao H, Ye J, Zhao X, Zhang Y. Conductive Polymer Nanoparticles as Solid Contact in Ion-Selective Electrodes Sensitive to Potassium Ions. Molecules 2023; 28:molecules28073242. [PMID: 37050005 PMCID: PMC10096689 DOI: 10.3390/molecules28073242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 03/28/2023] [Accepted: 04/02/2023] [Indexed: 04/08/2023] Open
Abstract
A preparation method of nanocomposites based on poly (3-octylthiophene-2,5-diyl) (POT) and carbon black (CB) as the transducer of an all-solid potassium ion selective electrode is proposed. POT is used as the dispersant of CB, and the obtained nanocomposites have unique characteristics, including high conductivity, high capacitance and high stability. The potassium ion selective electrode based on POT and CB was characterized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and chronopotentiometry. The results showed that the detection limit of potassium ions was 10−6.2 M, and the slope was 57.6 ± 0.8 mV/façade. The water layer test and anti-interference test show that the electrode has high hydrophobicity, the static contact angle reaches 139.7° and is not easily affected by light, O2 and CO2.
Collapse
Affiliation(s)
- Hui Bao
- College of Information Science and Engineering, Henan University of Technology, Zhengzhou 450001, China
| | - Jin Ye
- College of Information Science and Engineering, Henan University of Technology, Zhengzhou 450001, China
| | - Xuyan Zhao
- College of Electrical Engineering, Henan University of Technology, Zhengzhou 450001, China
| | - Yuan Zhang
- College of Information Science and Engineering, Henan University of Technology, Zhengzhou 450001, China
| |
Collapse
|
5
|
Reznicek J, Bednarik V, Filip J. PERCHLORATE SENSING – CAN ELECTROCHEMISTRY MEET THE SENSITIVITY OF STANDARD METHODS? Electrochim Acta 2023. [DOI: 10.1016/j.electacta.2023.142027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023]
|
6
|
Detection of benzalkonium chloride and polyhexamethylene guanidine hydrochloride using novel organic gel-based amperometric electrode and HILIC DAD. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
7
|
Rizk M, Hussein EM, Toubar S, Ramzy E, Helmy MI. Screen-printed sensors for efficient potentiometric analysis of tolperisone hydrochloride in presence of its co-formulated drugs. BMC Chem 2022; 16:89. [PMID: 36345022 PMCID: PMC9641925 DOI: 10.1186/s13065-022-00883-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Accepted: 10/25/2022] [Indexed: 11/09/2022] Open
Abstract
Researchers seeking for green chemistry to help safeguard and boost the economy and the environment by discovering unique ways to decrease waste and find substitutes for dangerous chemicals. In this study, a green potentiometric ion-selective electrode (ISE) was developed for measurement of tolperisone HCl (TOLP) in bulk and Pharmaceutical dosage forms in presence of diclofenac sodium and paracetamol as co-formulated drugs. This paper presents the manufacture and characterization of a disposable potentiometric ion-selective strip with an enhanced detection limit for (TOLP) measurement in its tablet dosage form either alone or in presence of the co-formulated drugs. Numerous ion pairs (IPs), such as TOLP-tetraphenylborate (TOLP-TPB), TOLP-phosphotungstic acid (TOLP-PTA), and TOLP-ammonium Reinecke (TOLP- RKT) are tested in presence of different plasticizers. The optimal potentiometric response with a near Nernstian slope of 55.949 mV/decade was achieved within a linear concentration range of 5 \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\times$$\end{document}× 10–5 − 1 \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\times$$\end{document}× 10–2 M using (PTA) and ortho nitrophenyl octyl ether (o-NPOE) as a plasticizer. The effect of the nanoparticles on the membrane stability was studied using the graphene nanoplatelets which have an effective role in the enhancement of some constructed sensors stability. Finally, the developed technique is validated for the estimation of TOLP with high accuracy and precision.
Collapse
|
8
|
Budetić M, Samardžić M, Bubnjar K, Dandić A, Živković P, Széchenyi A, Kiss L. A new sensor for direct potentiometric determination of thiabendazole in fruit peels using the Gran method. Food Chem 2022; 392:133290. [PMID: 35660977 DOI: 10.1016/j.foodchem.2022.133290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Revised: 05/20/2022] [Accepted: 05/20/2022] [Indexed: 11/29/2022]
Abstract
A new sensor for direct potentiometric determination of thiabendazole (TBZ) was prepared. The ionic pair of TBZ cation and the 5-sulfosalicylate anion was used as the new sensor material incorporated in liquid type of ion-selective electrode membrane for TBZ determination. For optimization of the membrane of the sensor for TBZ determination, six different plasticizers and the content of the sensor material in the membrane were varied. The chosen sensor with dibutyl sebacate (DS) as plasticizer and 1% of sensor material in the membrane was characterized with Nernstian response towards TBZ (62.2 mV/decade of activity), a wide working range (8.6∙10-7-1.0∙10-3 M), and a low limit of detection (3.2·10-7 M). Also, it proved to be an accurate and reliable sensor for TBZ determination in pure and real samples (peel of oranges, lemons and bananas) where it was determined using direct potentiometry and Gran method.
Collapse
Affiliation(s)
- Mateja Budetić
- Department of Chemistry, Josip Juraj Strossmayer University of Osijek, Cara Hadrijana 8/A, 31000 Osijek, Croatia
| | - Mirela Samardžić
- Department of Chemistry, Josip Juraj Strossmayer University of Osijek, Cara Hadrijana 8/A, 31000 Osijek, Croatia
| | - Karlo Bubnjar
- Department of Chemistry, Josip Juraj Strossmayer University of Osijek, Cara Hadrijana 8/A, 31000 Osijek, Croatia
| | - Andrea Dandić
- Department of Chemistry, Josip Juraj Strossmayer University of Osijek, Cara Hadrijana 8/A, 31000 Osijek, Croatia
| | - Pavo Živković
- Department of Chemistry, Josip Juraj Strossmayer University of Osijek, Cara Hadrijana 8/A, 31000 Osijek, Croatia
| | - Aleksandar Széchenyi
- Department of Chemistry, Josip Juraj Strossmayer University of Osijek, Cara Hadrijana 8/A, 31000 Osijek, Croatia
| | - László Kiss
- Department of Organic and Pharmacological Chemistry, University of Pécs, Honvéd street 1, H-7624 Pécs, Hungary; János Szentágothai Research Center, Ifjúság street 20, H-7624 Pécs, Hungary.
| |
Collapse
|
9
|
Qi L, Liang R, Jiang T, Qin W. Anti-fouling polymeric membrane ion-selective electrodes. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116572] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
10
|
Sharma R, Geranpayehvaghei M, Ejeian F, Razmjou A, Asadnia M. Recent advances in polymeric nanostructured ion selective membranes for biomedical applications. Talanta 2021; 235:122815. [PMID: 34517671 DOI: 10.1016/j.talanta.2021.122815] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Revised: 08/13/2021] [Accepted: 08/18/2021] [Indexed: 12/30/2022]
Abstract
Nano structured ion-selective membranes (ISMs) are very attractive materials for a wide range of sensing and ion separation applications. The present review focuses on the design principles of various ISMs; nanostructured and ionophore/ion acceptor doped ISMs, and their use in biomedical engineering. Applications of ISMs in the biomedical field have been well-known for more than half a century in potentiometric analysis of biological fluids and pharmaceutical products. However, the emergence of nanotechnology and sophisticated sensing methods assisted in miniaturising ion-selective electrodes to needle-like sensors that can be designed in the form of implantable or wearable devices (smartwatch, tattoo, sweatband, fabric patch) for health monitoring. This article provides a critical review of recent advances in miniaturization, sensing and construction of new devices over last decade (2011-2021). The designing of tunable ISM with biomimetic artificial ion channels offered intensive opportunities and innovative clinical analysis applications, including precise biosensing, controlled drug delivery and early disease diagnosis. This paper will also address the future perspective on potential applications and challenges in the widespread use of ISM for clinical use. Finally, this review details some recommendations and future directions to improve the accuracy and robustness of ISMs for biomedical applications.
Collapse
Affiliation(s)
- Rajni Sharma
- School of Engineering, Macquarie University, Sydney, NSW, 2109, Australia
| | - Marzieh Geranpayehvaghei
- School of Engineering, Macquarie University, Sydney, NSW, 2109, Australia; Department of Nanobiotechnology, Faculty of Biological Sciences, Tarbiat Modares University, Tehran, 14115-175, Iran
| | - Fatemeh Ejeian
- Department of Animal Biotechnology, Cell Science Research Center, Royan Institute for Biotechnology, ACECR, Isfahan, Iran; Department of Biotechnology, Faculty of Biological Science and Technology, University of Isfahan, Isfahan, 73441-81746, Iran
| | - Amir Razmjou
- School of Engineering, Macquarie University, Sydney, NSW, 2109, Australia; Department of Biotechnology, Faculty of Biological Science and Technology, University of Isfahan, Isfahan, 73441-81746, Iran; Centre for Technology in Water and Wastewater, University of Technology Sydney, New South Wales, Australia; UNESCO Center for Membrane Technology, School of Chemical Engineering, University of New South Wales, Sydney, NSW, 2052, Australia
| | - Mohsen Asadnia
- School of Engineering, Macquarie University, Sydney, NSW, 2109, Australia.
| |
Collapse
|
11
|
Cheong YH, Lisak G. Physically Tailoring Ion Fluxes by Introducing Foamlike Structures into Polymeric Membranes of Solid Contact Ion-Selective Electrodes. ACS Sens 2021; 6:3667-3676. [PMID: 34585917 DOI: 10.1021/acssensors.1c01413] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Transmembrane ion fluxes have earlier been identified as a source of potential instability in solid contact ion-selective electrodes (SC-ISEs). In this work, foamlike structures were intentionally introduced into a potassium-sensitive plasticized poly(vinyl chloride) ion-selective membrane (ISM) near the membrane|solid contact interface by controlling the temperature during membrane deposition. Foamlike structures in the ISM were shown to be effective at physically tailoring the transport of ions in the ion-selective membrane, greatly reducing the flux of interfering ions from the sample to the membrane|solid contact interface. The drifts during a conventional water layer test were hence able to be greatly mitigated, even with SC-ISEs incorporating a relatively hydrophilic poly(3,4-ethylenedioxythiophene) doped with poly(styrenesulfonate) (PEDOT:PSS) solid contact. In solutions with a high background concentration of interfering ions, equilibrated ion-selective electrodes with foamlike membranes were able to reproduce their initial potentials within 0.6 mV uncertainty (n = 3) from 0 to 18 h. This was achieved despite sensor exposure to solutions exceeding the selectivity limit of the ISEs in 3 h intervals, allowing improvement of the potential reproducibility of the sensors. Since the introduction of foamlike structures into ISM is linked to temperature-controlled membrane deposition, it is envisaged that the method is generally applicable to all solid contact ion-selective electrodes that are based on polymeric membranes and require membrane deposition from the cocktail solution.
Collapse
Affiliation(s)
- Yi Heng Cheong
- College of Engineering, School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore
- Nanyang Environment and Water Research Institute, Residues and Resource Reclamation Center, 1 Cleantech Loop, Cleantech, Singapore 637141, Singapore
- Robert Bosch (South East Asia) Pte Ltd., 11 Bishan Street 21, Singapore 573943, Singapore
| | - Grzegorz Lisak
- College of Engineering, School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore
- Nanyang Environment and Water Research Institute, Residues and Resource Reclamation Center, 1 Cleantech Loop, Cleantech, Singapore 637141, Singapore
| |
Collapse
|
12
|
Mohamad Nor N, Ramli NH, Poobalan H, Qi Tan K, Abdul Razak K. Recent Advancement in Disposable Electrode Modified with Nanomaterials for Electrochemical Heavy Metal Sensors. Crit Rev Anal Chem 2021; 53:253-288. [PMID: 34565248 DOI: 10.1080/10408347.2021.1950521] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Heavy metal pollution has gained global attention due to its high toxicity and non-biodegradability, even at a low level of exposure. Therefore, the development of a disposable electrode that is sensitive, simple, portable, rapid, and cost-effective as the sensor platform in electrochemical heavy metal detection is vital. Disposable electrodes have been modified with nanomaterials so that excellent electrochemical properties can be obtained. This review highlights the recent progress in the development of numerous types of disposable electrodes modified with nanomaterials for electrochemical heavy metal detection. The disposable electrodes made from carbon-based, glass-based, and paper-based electrodes are reviewed. In particular, the analytical performance, fabrication technique, and integration design of disposable electrodes modified with metal (such as gold, tin and bismuth), carbon (such as carbon nanotube and graphene), and metal oxide (such as iron oxide and zinc oxide) nanomaterials are summarized. In addition, the role of the nanomaterials in improving the electrochemical performance of the modified disposable electrodes is discussed. Finally, the current challenges and future prospect of the disposable electrode modified with nanomaterials are summarized.
Collapse
Affiliation(s)
- Noorhashimah Mohamad Nor
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Nurul Hidayah Ramli
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Hemalatha Poobalan
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Kai Qi Tan
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia
| | - Khairunisak Abdul Razak
- School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia.,NanoBiotechnology Research & Innovation (NanoBRI), Institute for Research in Molecular Medicine, Universiti Sains Malaysia, 11800 USM, Pulau Pinang, Malaysia
| |
Collapse
|
13
|
The Influence of Plasticizers on the Response Characteristics of the Surfactant Sensor for Cationic Surfactant Determination in Disinfectants and Antiseptics. SENSORS 2021; 21:s21103535. [PMID: 34069524 PMCID: PMC8161289 DOI: 10.3390/s21103535] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Revised: 05/18/2021] [Accepted: 05/18/2021] [Indexed: 11/16/2022]
Abstract
Surfactant liquid-membrane type sensors are usually made of a PVC, ionophore and a plasticizer. Plasticizers soften the PVC. Due to their lipophilicity, they influence the ion exchange across the membrane, ionophore solubility, membrane resistance and, consequently, the analytical signal. We used the DMI-TPB as an ionophore, six different plasticizers [2-nitrophenyl-octyl-ether (P1), bis(2-ethylhexyl) phthalate (P2), bis(2-ethylhexyl) sebacate (P3), 2-nitrophenyl phenyl ether (P4), dibutyl phthalate (P5) and dibutyl sebacate (P6)] and a PVC to produce ionic surfactant sensors. Sensor formulation with P1 showed the best potentiometric response to four usually used cationic surfactant, with the lowest LOD, 7 × 10−7 M; and potentiometric titration curves with well-defined and sharp inflexion points. The sensor with P6 showed the lowest analytical performances. Surfactant sensor with P1 was selected for quantification of cationic surfactant in model solutions and commercial samples of disinfectants and antiseptics. It showed high accuracy and precision in all determinations, with recovery from 98.2 to 99.6, and good agreement with the results obtained with surfactant sensor used as a referent one, and a standard two-phase titration method. RDS values were lower than 0.5% for all determinations.
Collapse
|
14
|
Kelani KM, Badran OM, Rezk MR, Elghobashy MR, Eid SM. Widening the applications of the Just-Dip-It approach: a solid contact screen-printed ion-selective electrode for the real-time assessment of pharmaceutical dissolution testing in comparison to off-line HPLC analysis. RSC Adv 2021; 11:13366-13375. [PMID: 35423846 PMCID: PMC8697630 DOI: 10.1039/d1ra00040c] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2021] [Accepted: 03/22/2021] [Indexed: 12/03/2022] Open
Abstract
Over past years, the field of pharmaceutical dissolution testing has significantly expanded to cover not only the quality control of dosage forms, but also to play an important role in the bioavailability testing paradigm and screening of most formulations. These tests usually need a very long time sampling and monitoring, so that the automation of sampling is laborsaving. Problems often occur with these automatic devices due to sampling lines that may disconnect, crimp, carry over, become mixed up, or are inadequately cleaned. Potentiometric sensors, such as liquid contact (LC-ISE) or solid contact ion-selective electrodes (SC-SP-ISE), can provide timely data to be used for the real-time tracking of the amount of active pharmaceutical ingredients (APIs) released in the dissolution medium without these problems. In this work, we adopted the Just-Dip-It approach as a process analytical technology solution with the ultimate goal of advancing the ion selective sensors to their most effective use in pharmaceutical analysis. Two sensors were fabricated, the traditional LC-ISE and SC-SP-ISE. The sensing poly-vinyl chloride membranes of two electrodes were prepared using 2-nitrophenyl octyl ether as a plasticizer to soften the membrane, and the reduction in resistance to pioglitazone ions (PIO) permeability was achieved through the incorporation of sodium tetraphenylborate and calix[8]arene as a cationic exchanger salt and inclusion complexing ligand, respectively. Finally, prepared membranes were turned into the flexible perm-selective slices of hydrophobic plastic, which work as a barrier to other compounds, except for the PIO cation in the concentration range of 1 × 10-6 to 1 × 10-2 M and 1 × 10-5 to 1 × 10-2 M for SC-SP-ISE and LC-ISE, respectively. The challenges and opportunities of both sensors in comparison to a developed HPLC method were discussed for the dissolution testing of the combination dosage forms of pioglitazone. Potentiometric methods were validated according to IUPAC guidelines, while HPLC was validated according to ICH guidelines to ensure accuracy and precision.
Collapse
Affiliation(s)
- Khadiga M Kelani
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University Kasr El-Aini Street ET-11562 Cairo Egypt
- Analytical Chemistry Department, Faculty of Pharmacy, Modern University for Technology and Information Cairo Egypt
| | - Osama M Badran
- Analytical Chemistry Department, Faculty of Pharmacy, Modern University for Technology and Information Cairo Egypt
| | - Mamdouh R Rezk
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University Kasr El-Aini Street ET-11562 Cairo Egypt
| | - Mohamed R Elghobashy
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University Kasr El-Aini Street ET-11562 Cairo Egypt
- Analytical Chemistry Department, Faculty of Pharmacy, October 6 University 6 October City, Giza Egypt
| | - Sherif M Eid
- Analytical Chemistry Department, Faculty of Pharmacy, October 6 University 6 October City, Giza Egypt
| |
Collapse
|
15
|
Development of ion-selective electrodes for antipyrine and its derivatives as potential tool for environmental water monitoring. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115110] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
16
|
Sakač N, Marković D, Šarkanj B, Madunić-Čačić D, Hajdek K, Smoljan B, Jozanović M. Direct Potentiometric Study of Cationic and Nonionic Surfactants in Disinfectants and Personal Care Products by New Surfactant Sensor Based on 1,3-Dihexadecyl-1 H-benzo[ d]imidazol-3-ium. Molecules 2021; 26:1366. [PMID: 33806643 PMCID: PMC7961908 DOI: 10.3390/molecules26051366] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 02/25/2021] [Accepted: 02/26/2021] [Indexed: 12/16/2022] Open
Abstract
A novel, simple, low-cost, and user-friendly potentiometric surfactant sensor based on the new 1,3-dihexadecyl-1H-benzo[d]imidazol-3-ium-tetraphenylborate (DHBI-TPB) ion-pair for the detection of cationic surfactants in personal care products and disinfectants is presented here. The new cationic surfactant DHBI-Br was successfully synthesized and characterized by nuclear magnetic resonance (NMR), Fourier transform infrared (FTIR) spectrometry, liquid chromatography-mass spectrometry (LC-MS) and elemental analysis and was further employed for DHBI-TPB ion-pair preparation. The sensor gave excellent response characteristics for CTAB, CPC and Hyamine with a Nernstian slope (57.1 to 59.1 mV/decade) whereas the lowest limit of detection (LOD) value was measured for CTAB (0.3 × 10-6 M). The sensor exhibited a fast dynamic response to dodecyl sulfate (DDS) and TPB. High sensor performances stayed intact regardless of the employment of inorganic and organic cations and in a broad pH range (2-11). Titration of cationic and etoxylated (EO)-nonionic surfactant (NSs) (in Ba2+) mixtures with TPB revealed the first inflexion point for a cationic surfactant and the second for an EO-nonionic surfactant. The increased concentration of EO-nonionic surfactants and the number of EO groups had a negative influence on titration curves and signal change. The sensor was successfully applied for the quantification of technical-grade cationic surfactants and in 12 personal care products and disinfectants. The results showed good agreement with the measurements obtained by a commercial surfactant sensor and by a two-phase titration. A good recovery for the standard addition method (98-102%) was observed.
Collapse
Affiliation(s)
- Nikola Sakač
- Faculty of Geotechnical Engineering, University of Zagreb, 42000 Varaždin, Croatia;
| | - Dean Marković
- Department of Biotechnology, University of Rijeka, 51000 Rijeka, Croatia;
| | - Bojan Šarkanj
- Department of Food Technology, University North, 48000 Koprivnica, Croatia;
| | - Dubravka Madunić-Čačić
- Faculty of Geotechnical Engineering, University of Zagreb, 42000 Varaždin, Croatia;
- Saponia Chemical, Pharmaceutical and Foodstuff Industry, Inc., 31000 Osijek, Croatia
| | - Krunoslav Hajdek
- Department of Packaging, Recycling and Environmental Protection, University North, 48000 Koprivnica, Croatia; (K.H.); (B.S.)
| | - Božo Smoljan
- Department of Packaging, Recycling and Environmental Protection, University North, 48000 Koprivnica, Croatia; (K.H.); (B.S.)
| | - Marija Jozanović
- Department of Chemistry, University of Osijek, 31000 Osijek, Croatia
| |
Collapse
|
17
|
Potentiometric Carboxylate Sensors Based on Carbazole-Derived Acyclic and Macrocyclic Ionophores. CHEMOSENSORS 2020. [DOI: 10.3390/chemosensors9010004] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Solid-contact ion-selective electrodes with carbazole-derived ionophores were prepared. They were characterized as acetate sensors, but can be used to determine a number of carboxylates. The potentiometric response characteristics (slope, detection limit, selectivity, and pH sensitivity) of sensors prepared with different membrane compositions (ionophore, ionophore concentration, anion exchanger concentration, and plasticizer) were evaluated. The results show that for the macrocyclic ionophores, a larger cavity provided better selectivity. The sensors exhibited modest selectivity for acetate but good selectivity for benzoate. The carbazole-derived ionophores effectively decreased the interference from lipophilic anions, such as bromide, nitrate, iodide, and thiocyanate. The selectivity, detection limit, and linear range were improved by choosing a suitable plasticizer and by reducing the ionophore and anion exchanger concentrations. The influence of the electrode body’s material upon the composition of the plasticized poly(vinyl chloride) membrane, and thus also upon the sensor characteristics, was also studied. The choice of materials for the electrode body significantly affected the characteristics of the sensors.
Collapse
|
18
|
Alarfaj NA, El-Tohamy MF. New Functionalized Polymeric Sensor Based NiO/MgO Nanocomposite for Potentiometric Determination of Doxorubicin Hydrochloride in Commercial Injections and Human Plasma. Polymers (Basel) 2020; 12:E3066. [PMID: 33371354 PMCID: PMC7767339 DOI: 10.3390/polym12123066] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2020] [Accepted: 12/17/2020] [Indexed: 12/24/2022] Open
Abstract
The ultra-functional potential of nickel oxide (NiO) and magnesium oxide (MgO) nanoparticles (NPs), provides for extensive attention in the use of these metal oxides as a remarkable and electroactive nanocomposite in potentiometric and sensing investigations. This work proposed a new strategy for quantifying doxorubicin hydrochloride (DOX) in pharmaceuticals and human plasma by preparing a NiO/MgO core-shell nanocomposite modified coated wire membrane sensor. Doxorubicin hydrochloride was incorporated with phosphomolybdic acid (PMA) to produce doxorubicin hydrochloride phosphomolybdate (DOX-PM) as an electroactive material in the presence of polymeric high molecular weight poly vinyl chloride (PVC) and solvent mediator o-nitrophenyloctyl ether (o-NPOE). The modified sensor exhibited ultra sensitivity and high selectivity for the detection and quantification of doxorubicin hydrochloride with a linear relationship in the range of 1.0 × 10-11-1.0 × 10-2 mol L-1. The equation of regression was estimated to be EmV = (57.86 ± 0.8) log [DOX] + 723.19. However, the conventional type DOX-PM showed a potential response over a concentration range of 1.0 × 10-6-1.0 × 10-2 mol L-1 and a regression equation of EmV = (52.92 ± 0.5) log [DOX] + 453.42. The suggested sensors were successfully used in the determination of doxorubicin hydrochloride in commercial injections and human plasma.
Collapse
Affiliation(s)
| | - Maha F. El-Tohamy
- Department of Chemistry, College of Science, King Saud University, P.O. Box 22452, Riyadh 11495, Saudi Arabia;
| |
Collapse
|
19
|
Fan Y, Xu Z, Huang Y, Wang T, Zheng S, DePasquale A, Brüeckner C, Lei Y, Li B. Long-term continuous and real-time in situ monitoring of Pb(II) toxic contaminants in wastewater using solid-state ion selective membrane (S-ISM) Pb and pH auto-correction assembly. JOURNAL OF HAZARDOUS MATERIALS 2020; 400:123299. [PMID: 32947704 DOI: 10.1016/j.jhazmat.2020.123299] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2020] [Revised: 06/17/2020] [Accepted: 06/22/2020] [Indexed: 05/12/2023]
Abstract
Lead (Pb) contaminants in wastewater have inhibited microbial activities and thus exerted high energy consumption in wastewater treatment plants (WWTPs). Current Pb monitoring has been conducted ex situ and off line, unable to affect real-time proactive control and operation. This study targets the crucial challenge of better and faster Pb monitoring by developing novel mm-sized screen-printed solid-state ion-selective membrane (S-ISM) Pb sensors with low-cost, high accuracy and long-term durability and that enable real-time in situ monitoring of Pb(II) ion contamination down to low concentrations (15 ppb-960 ppb) in wastewater. An innovative pH auto-correction data-driven model was built to overcome the inextricable pH inferences on Pb(II) ISM sensors in wastewater. Electrochemical impedance spectroscopy (EIS) and cyclic voltammograms (CV) analysis showed (3,4-ethylenedioxythiophene, EDOT) deposited onto the mm-sized screen-printed carbon electrodes using electropolymerization effectively alleviated the interferences from dissolved oxygen and improved long-term stability in wastewater. Monte Carlo simulation of the nitrification process predicted that real-time, and high accurate in situ monitoring of Pb(II) in wastewater and swift feedback control could save ∼53 % of energy consumption by alleviating the errors from pH and DO impacts in WWTPs.
Collapse
Affiliation(s)
- Yingzheng Fan
- Department of Civil & Environmental Engineering, University of Connecticut, Storrs, CT 06269-3037, United States
| | - Zhiheng Xu
- Department of Civil & Environmental Engineering, University of Connecticut, Storrs, CT 06269-3037, United States
| | - Yuankai Huang
- Department of Civil & Environmental Engineering, University of Connecticut, Storrs, CT 06269-3037, United States
| | - Tianbao Wang
- Department of Civil & Environmental Engineering, University of Connecticut, Storrs, CT 06269-3037, United States
| | - Sikai Zheng
- Department of Civil & Environmental Engineering, University of Connecticut, Storrs, CT 06269-3037, United States
| | - Alex DePasquale
- Department of Civil & Environmental Engineering, University of Connecticut, Storrs, CT 06269-3037, United States
| | - Christian Brüeckner
- Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060, United States
| | - Yu Lei
- Department of Chemical and Biomedical Engineering, University of Connecticut, Storrs, CT 06269-3222, United States
| | - Baikun Li
- Department of Civil & Environmental Engineering, University of Connecticut, Storrs, CT 06269-3037, United States.
| |
Collapse
|
20
|
Al-Mohaimeed AM, A. Al-Onazi W, El-Tohamy MF. Utility of Zinc Oxide Nanoparticles Catalytic Activity in the Electrochemical Determination of Minocycline Hydrochloride. Polymers (Basel) 2020; 12:E2505. [PMID: 33126425 PMCID: PMC7694109 DOI: 10.3390/polym12112505] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Revised: 10/20/2020] [Accepted: 10/21/2020] [Indexed: 11/16/2022] Open
Abstract
The current work described the synthesis and characterization of zinc oxide nanoparticles (ZnONPs) and their electrocatalytic activity in the determination of minocycline hydrochloride (MCL). The unique features of metal oxide nanoparticles such as zinc oxide encourage the researchers to investigate the activity of metal oxide nanoparticles as remarkable semiconductor materials active in the electrochemical sensing determination. Herein, the suggested study displayed a comparative determination of minocycline hydrochloride using two conventional and modified ZnONPs-coated wire sensors. The recorded results showed the linear behavior of the enriched ZnONPs sensor over the 1.0 × 10-10-1.0 × 10-2 mol L-1 with respect to 1.0 × 10-6-1.0 × 10-2 mol L-1 for the conventional sensor. The two sensors are working in the pH range of 3-5 with regression equations EmV = (53.2 ± 0.5) log [MCL] + 448.8 and EmV = (58.7 ± 0.2) log [MCL] + 617.76 for conventional and enriched ZnONPs, respectively. The correlation coefficients were 0.9995 and 0.9998 for the previously mentioned sensors, respectively. The validity of the suggested analytical method was evaluated according to the recommended guidelines for methodology and drug analysis. The developed sensors were also used in the quantification of MCL in commercial formulations.
Collapse
Affiliation(s)
- Amal M. Al-Mohaimeed
- Department of Chemistry, College of Science, King Saud University, P.O. Box 22452, Riyadh 11495, Saudi Arabia; (W.A.A.-O.); (M.F.E.-T.)
| | | | | |
Collapse
|
21
|
Eid SM. Indirect Nano-sensing approach: A universal potentiometric silver ion selective sensor for inline quantitative profiling of the kinetics and thermodynamics of formation and decay of silver nanoparticles. Talanta 2020; 218:121135. [PMID: 32797892 DOI: 10.1016/j.talanta.2020.121135] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Revised: 05/02/2020] [Accepted: 05/06/2020] [Indexed: 11/27/2022]
Abstract
Indirect Nano-sensing are indispensable chemical sensory points that make use of the unique properties of nanoparticles to derive information about it to our macroscopic world. Precious Silver nanoparticles have become more attractive in many areas of healthcare and life sciences leading to massive industrial production and increase of environmental exposure which may lead to Nanotoxicity accompanied by the release of Ag+ ions. A reversible silver selective screen-printed electrode was fabricated, optimized, and validated. A wide linearity range of 1 × 10-6 - 1 × 10-2 M was obtained, with a LOD that reaches 1.5 × 10-7 M and a typical slope of monovalent cationic compounds of 59.6 mV/decade. It showed high selectivity towards the cationic Ag+ ion activity in presence of the negatively charged citrate capped silver nanoparticles (Cit-AgNPs). The fabricated sensor has been used for tracking the decrease of Ag+ activity during the reduction of AgNO3 with tri-sodium citrate during the Bottom-up synthesis of Cit-AgNPs at different temperature (60, 70 and 80 °C). The kinetic parameters (Activation energy (Ea) and Reaction rate (K)) and the thermodynamic characteristics (free activation energy (ΔG), entropy (ΔS), enthalpy (ΔH)) have been calculated. Furthermore, it has been used for tracking the release of Ag+ during the spontaneous and stimulated decay of Cit-AgNPs. The present work could be a junction between nanotechnology and recent advances in design of a reproducible, portable real-time analyzer for in-process monitoring of the production of Cit-AgNPs and its environmental hazards with many advantages in comparison to the reported techniques in terms of portability, simplicity, cost-efficient, fast inline tracking, no sampling, real-time profiles at high temperatures and it does not need professional operators.
Collapse
Affiliation(s)
- Sherif M Eid
- Analytical Chemistry Department, Faculty of Pharmacy, October 6 University, 6 October City, Giza, Egypt.
| |
Collapse
|
22
|
Unintended Changes of Ion-Selective Membranes Composition-Origin and Effect on Analytical Performance. MEMBRANES 2020; 10:membranes10100266. [PMID: 32998393 PMCID: PMC7601616 DOI: 10.3390/membranes10100266] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/29/2020] [Revised: 09/22/2020] [Accepted: 09/23/2020] [Indexed: 01/28/2023]
Abstract
Ion-selective membranes, as used in potentiometric sensors, are mixtures of a few important constituents in a carefully balanced proportion. The changes of composition of the ion-selective membrane, both qualitative and quantitative, affect the analytical performance of sensors. Different constructions and materials applied to improve sensors result in specific conditions of membrane formation, in consequence, potentially can result in uncontrolled modification of the membrane composition. Clearly, these effects need to be considered, especially if preparation of miniaturized, potentially disposable internal-solution free sensors is considered. Furthermore, membrane composition changes can occur during the normal operation of sensors—accumulation of species as well as release need to be taken into account, regardless of the construction of sensors used. Issues related to spontaneous changes of membrane composition that can occur during sensor construction, pre-treatment and their operation, seem to be underestimated in the subject literature. The aim of this work is to summarize available data related to potentiometric sensors and highlight the effects that can potentially be important also for other sensors using ion-selective membranes, e.g., optodes or voltammetric sensors.
Collapse
|
23
|
Zhang C, Hao T, Lin H, Wang Q, Wu Y, Kang K, Ji X, Guo Z. One-step electrochemical sensor based on an integrated probe toward sub-ppt level Pb 2+ detection by fast scan voltammetry. Anal Chim Acta 2020; 1128:174-183. [PMID: 32825900 DOI: 10.1016/j.aca.2020.07.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 06/29/2020] [Accepted: 07/02/2020] [Indexed: 01/14/2023]
Abstract
Herein, a one-step electrochemical sensor for selective and sensitive detection of lead ion Pb2+ was developed based on an integrated probe meso-tetra(4-carboxyphenyl) porphine (TCPP)-multi-walled carbon nanotubes (MWCNTs)@Fe3O4, which is TCPP-modified magnetic multi-walled carbon nanotubes. In the integrated probe, TCPP is a porphyrin with a specific cavity structure which could selectively chelate with Pb2+, MWCNTs with good electric conductivity provide a place to load TCPP and form a specific adsorption state of Pb2+ on the electrode surface, and Fe3O4 enables the rapid separation and one-step fabrication of the electrochemical sensor. Based on it, the sample pre-enrichment, separation and determination can be integrated, making the whole process very fast and simple. In addition, fast scan voltammetry (FSV) with a scan rate up to 200 V/s could be used to improve the detection sensitivity greatly, benefitting from the specific adsorption state formed. Under the optimal conditions obtained through orthogonal experiments including adsorption time, integrated probe dosage and solution pH, there was a good linear relationship between the peak current and Pb2+ concentration ranging from 2.0 × 10-4 μg L-1 to 2.0 × 10-3 μg L-1, with the limit of detection (LOD) being 6.7 × 10-5 μg L-1 (S/N = 3) i.e. 0.067 ppt. Analysis of actual water samples was successful. Therefore, being simple, fast, selective and sensitive, the one-step electrochemical sensor proposed has a good potential in practical applications.
Collapse
Affiliation(s)
- Chunfeng Zhang
- State Key Laboratory for Managing Biotic, Chemical Threats to the Quality, Safety of Agro-products, School of Materials Science and Chemical Engineering, Ningbo University, Ningbo, 315211, PR China
| | - Tingting Hao
- State Key Laboratory for Managing Biotic, Chemical Threats to the Quality, Safety of Agro-products, School of Materials Science and Chemical Engineering, Ningbo University, Ningbo, 315211, PR China
| | - Han Lin
- State Key Laboratory for Managing Biotic, Chemical Threats to the Quality, Safety of Agro-products, School of Materials Science and Chemical Engineering, Ningbo University, Ningbo, 315211, PR China
| | - Qi Wang
- State Key Laboratory for Managing Biotic, Chemical Threats to the Quality, Safety of Agro-products, School of Materials Science and Chemical Engineering, Ningbo University, Ningbo, 315211, PR China
| | - Yangbo Wu
- Faculty of Electrical Engineering and Computer Science, Ningbo University, Ningbo, 315211, PR China
| | - Kai Kang
- School of Pharmacy, Hebei Medical University, Shijiazhuang, 050017, PR China
| | - Xueping Ji
- School of Pharmacy, Hebei Medical University, Shijiazhuang, 050017, PR China
| | - Zhiyong Guo
- State Key Laboratory for Managing Biotic, Chemical Threats to the Quality, Safety of Agro-products, School of Materials Science and Chemical Engineering, Ningbo University, Ningbo, 315211, PR China.
| |
Collapse
|
24
|
Kormosh ZA, Matviichuk OY, Antal IP, Bazel’ YR. Sensors Based on Single- and Double-Layer Plasticized Membranes for the Potentiometric Determination of Mefenamic and Phenylanthranylic Acids. JOURNAL OF ANALYTICAL CHEMISTRY 2020. [DOI: 10.1134/s1061934820060131] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
25
|
Urbanowicz M, Sadowska K, Pijanowska DG, Pomećko R, Bocheńska M. Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva. SENSORS (BASEL, SWITZERLAND) 2020; 20:E2817. [PMID: 32429165 PMCID: PMC7288078 DOI: 10.3390/s20102817] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Revised: 05/06/2020] [Accepted: 05/12/2020] [Indexed: 12/13/2022]
Abstract
A new solid-contact potentiometric ion-selective electrode for the determination of SCN- (SCN-ISE) has been described. Synthesized phosphonium derivative of calix[4]arene was used as a charged ionophore. The research included selection of the ion-selective membrane composition, determination of the ISEs metrological parameters and SCN-ISE application for thiocyanate determination in human saliva. Preparation of the ISEs included selection of a plasticizer for the ion-selective membrane composition and type of the electrode material. The study was carried out using ISE with liquid internal electrolyte (LE-ISE) and solid-contact electrodes made of glassy carbon (GC-ISE) and gold rods (Au-ISE). The best parameters were found for GC sensors for which the ion-selective membrane contained chloroparaffin as a plasticizer (S = 59.9 mV/dec, LOD = 1.6 ´ 10-6 M). The study of potentiometric selectivity coefficients has shown that the thiocyanate-selective sensor could be applied in biomedical research for determination of SCN- concentration in human saliva. The accuracy of the SCN- determination was verified by testing 59 samples of volunteers' saliva by potentiometric sensors and UV-Vis spectrophotometry as a reference technique. Moreover, SCN- concentrations in the smokers' and non-smokers' saliva were compared. In order to investigate the influence of various factors (sex, health status, taken medications) on the thiocyanate level in the saliva, more extensive studies on a group of 100 volunteers were carried out. Additionally, for a group of 18 volunteers, individual profiles of SCN- concentration in saliva measured on a daily basis for over a month were collected.
Collapse
Affiliation(s)
- Marcin Urbanowicz
- Nalecz Institute of Biocybernetics and Biomedical Engineering Polish Academy of Sciences, Ks. Trojdena 4, 02-109 Warsaw, Poland; (K.S.); (D.G.P.)
| | - Kamila Sadowska
- Nalecz Institute of Biocybernetics and Biomedical Engineering Polish Academy of Sciences, Ks. Trojdena 4, 02-109 Warsaw, Poland; (K.S.); (D.G.P.)
| | - Dorota G. Pijanowska
- Nalecz Institute of Biocybernetics and Biomedical Engineering Polish Academy of Sciences, Ks. Trojdena 4, 02-109 Warsaw, Poland; (K.S.); (D.G.P.)
| | - Radosław Pomećko
- Department of Chemistry and Technology of Functional Materials, Chemical Faculty, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk, Poland; (R.P.); (M.B.)
| | - Maria Bocheńska
- Department of Chemistry and Technology of Functional Materials, Chemical Faculty, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk, Poland; (R.P.); (M.B.)
| |
Collapse
|
26
|
Enhancing electrode sensitivity for detection of antibiotic contamination in water using functionalized magnetic nanoparticles. SN APPLIED SCIENCES 2020. [DOI: 10.1007/s42452-020-2270-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022] Open
|
27
|
Shao Y, Ying Y, Ping J. Recent advances in solid-contact ion-selective electrodes: functional materials, transduction mechanisms, and development trends. Chem Soc Rev 2020; 49:4405-4465. [DOI: 10.1039/c9cs00587k] [Citation(s) in RCA: 143] [Impact Index Per Article: 35.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
This article presents a comprehensive overview of recent progress in the design and applications of solid-contact ion-selective electrodes (SC-ISEs).
Collapse
Affiliation(s)
- Yuzhou Shao
- Laboratory of Agricultural Information Intelligent Sensing
- School of Biosystems Engineering and Food Science
- Zhejiang University
- Hangzhou
- China
| | - Yibin Ying
- Laboratory of Agricultural Information Intelligent Sensing
- School of Biosystems Engineering and Food Science
- Zhejiang University
- Hangzhou
- China
| | - Jianfeng Ping
- Laboratory of Agricultural Information Intelligent Sensing
- School of Biosystems Engineering and Food Science
- Zhejiang University
- Hangzhou
- China
| |
Collapse
|
28
|
Zayed MA, Mahmoud WH, Abbas AA, Ali AE, Mohamed GG. A highly sensitive, selective and renewable carbon paste electrode based on a unique acyclic diamide ionophore for the potentiometric determination of lead ions in polluted water samples. RSC Adv 2020; 10:17552-17560. [PMID: 35515636 PMCID: PMC9053576 DOI: 10.1039/d0ra01435d] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Accepted: 04/20/2020] [Indexed: 11/22/2022] Open
Abstract
Due to the toxicity of lead(ii) to all living organisms as it destroys the central nervous system leading to circulatory system and brain disorders, the development of effective and selective lead(ii) ionophores for its detection is very important. In this work, 1,3-bis[2-(N-morpholino)acetamidophenoxy]propane (BMAPP), belonging to acyclic diamides, was applied as a highly selective lead(ii) ionophore in a carbon paste ion selective electrode for the accurate and precise determination of Pb(ii) ions even in the presence of other interfering ions. Factors affecting the electrode's response behavior were studied and optimized. Scanning electron microscopy (SEM), energy dispersive X-ray (EDX) and FT-IR spectroscopy were used for studying the morphology and response mechanism of the prepared sensor. The lipophilicity of the used ionophore, which contributes to the mechanical stability of the sensor, was studied using the contact angle measurement technique. The selectivity coefficients obtained by the separate solution method (SSM) and fixed interference method (FIM) confirmed the selectivity of the proposed sensor for Pb(ii) ions. The proposed sensor exhibited a Nernstian slope of 29.96 ± 0.34 mV per decade over a wide linear range of 5 × 10−8 to 1 × 10−1 mol L−1 and detection limit of 3 × 10−8 mol L−1 for 2 months with a fast response time (<10 s) and working pH range (2.5–5.5). To further ensure the practical applicability of the sensor, it was successfully applied for the lead(ii) ion determination in different water samples and the obtained data showed an agreement with those obtained by atomic absorption spectroscopy. In addition, it was successfully applied for the potentiometric titration of Pb(ii) against K2CrO4 and Na2SO4. Due to the toxicity of lead(ii) to all living organisms destroying the central nervous system and leading to circulatory system and brain disorders, the development of effective and selective lead(ii) ionophores for its detection is very important.![]()
Collapse
Affiliation(s)
- M. A. Zayed
- Chemistry Department
- Faculty of Science
- Cairo University
- Giza
- Egypt
| | | | - Ashraf A. Abbas
- Chemistry Department
- Faculty of Science
- Cairo University
- Giza
- Egypt
| | - Aya E. Ali
- Chemistry Department
- Faculty of Science
- Cairo University
- Giza
- Egypt
| | | |
Collapse
|
29
|
Pletnev IV, Smirnova SV, Shvedene NV. New Directions in Using Ionic Liquids in Analytical Chemistry. 2: Electrochemical Methods. JOURNAL OF ANALYTICAL CHEMISTRY 2019. [DOI: 10.1134/s1061934819070177] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
30
|
Matveichuk YV, Rakhman’ko EM. Ion-Selective Electrodes Based on Polyvinyl Chloride Modified by p-(Trifluoroacetyl)Benzoate Groups. JOURNAL OF ANALYTICAL CHEMISTRY 2019. [DOI: 10.1134/s1061934819040063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
31
|
Apel PY, Bobreshova OV, Volkov AV, Volkov VV, Nikonenko VV, Stenina IA, Filippov AN, Yampolskii YP, Yaroslavtsev AB. Prospects of Membrane Science Development. MEMBRANES AND MEMBRANE TECHNOLOGIES 2019. [DOI: 10.1134/s2517751619020021] [Citation(s) in RCA: 91] [Impact Index Per Article: 18.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
32
|
Sedaghat S, Jeong S, Zareei A, Peana S, Glassmaker N, Rahimi R. Development of a nickel oxide/oxyhydroxide-modified printed carbon electrode as an all solid-state sensor for potentiometric phosphate detection. NEW J CHEM 2019. [DOI: 10.1039/c9nj04502c] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
This work describes the preparation, characterization and use of a nickel oxide/oxyhydroxide-printed carbon electrode as an efficient potentiometric phosphate sensor.
Collapse
Affiliation(s)
- Sotoudeh Sedaghat
- Birck Nanotechnology Center
- Purdue University
- West Lafayette
- USA
- School of Materials Engineering
| | - Sookyoung Jeong
- Birck Nanotechnology Center
- Purdue University
- West Lafayette
- USA
- School of Materials Engineering
| | - Amin Zareei
- Birck Nanotechnology Center
- Purdue University
- West Lafayette
- USA
- School of Materials Engineering
| | - Samuel Peana
- School of Electrical and Computer Engineering
- Purdue University
- West Lafayette
- USA
| | | | - Rahim Rahimi
- Birck Nanotechnology Center
- Purdue University
- West Lafayette
- USA
- School of Materials Engineering
| |
Collapse
|
33
|
Highly selective solid-state sensor for iodide based on the combined use of platinum (IV) phthalocyanine and solidified pyridinium ionic liquid. J Solid State Electrochem 2018. [DOI: 10.1007/s10008-018-4159-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
34
|
Matveichuk YV, Rakhman’ko EM, Okaev EB. Carbonate-Selective Electrodes Based on Higher Quaternary Ammonium Salts with Increased Steric Accessibility of the Exchange Site. JOURNAL OF ANALYTICAL CHEMISTRY 2018. [DOI: 10.1134/s1061934818030097] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
35
|
Chemically modified (poly)vinyl chloride with built-in neutral carrier function as a new material for ion selective electrodes. CHEMICAL PAPERS 2017. [DOI: 10.1007/s11696-017-0356-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
36
|
Almeida MIGS, Cattrall RW, Kolev SD. Polymer inclusion membranes (PIMs) in chemical analysis - A review. Anal Chim Acta 2017; 987:1-14. [PMID: 28916032 DOI: 10.1016/j.aca.2017.07.032] [Citation(s) in RCA: 99] [Impact Index Per Article: 14.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2017] [Revised: 07/09/2017] [Accepted: 07/12/2017] [Indexed: 11/27/2022]
Abstract
This review highlights the increasing interest in polymer inclusion membranes (PIMs) in analytical chemistry as they are adapted to new and novel applications. PIMs are polymer-based liquid membranes and were first introduced 50 years ago as the sensing membranes in ion-selective electrodes and optodes. More recently however, PIMs have been used for other applications in analytical chemistry such as for sample separation, sample pre-concentration, electro-driven extraction, and passive sampling, and have also been incorporated into on-line and automated analysis systems. The present review provides a general overview of the analytical chemistry applications of PIMs reported in the literature to date and illustrates their versatility for solving challenging chemical analysis problems.
Collapse
Affiliation(s)
- M Inês G S Almeida
- School of Chemistry, The University of Melbourne, Victoria 3010, Australia
| | - Robert W Cattrall
- School of Chemistry, The University of Melbourne, Victoria 3010, Australia
| | - Spas D Kolev
- School of Chemistry, The University of Melbourne, Victoria 3010, Australia.
| |
Collapse
|
37
|
Bieg C, Fuchsberger K, Stelzle M. Introduction to polymer-based solid-contact ion-selective electrodes—basic concepts, practical considerations, and current research topics. Anal Bioanal Chem 2016; 409:45-61. [DOI: 10.1007/s00216-016-9945-6] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2016] [Revised: 07/26/2016] [Accepted: 09/14/2016] [Indexed: 11/30/2022]
|
38
|
Mikhelson KN, Peshkova MA. Advances and trends in ionophore-based chemical sensors. RUSSIAN CHEMICAL REVIEWS 2015. [DOI: 10.1070/rcr4506] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|