1
|
Zhang H, Zhang M, Zhou Y, Qiao Z, Gao L, Cao L, Yin H, Wang M. Organic photoelectrochemical transistor aptasensor for dual-mode detection of DEHP with CRISPR-Cas13a assisted signal amplification. JOURNAL OF HAZARDOUS MATERIALS 2024; 470:134175. [PMID: 38574662 DOI: 10.1016/j.jhazmat.2024.134175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 03/25/2024] [Accepted: 03/29/2024] [Indexed: 04/06/2024]
Abstract
Emerging organic photoelectrochemical transistors (OPECTs) with inherent amplification capabilities, good biocompatibility and even self-powered operation have emerged as a promising detection tool, however, they are still not widely studied for pollutant detection. In this paper, a novel OPECT dual-mode aptasensor was constructed for the ultrasensitive detection of di(2-ethylhexyl) phthalate (DEHP). MXene/In2S3/In2O3 Z-scheme heterojunction was used as a light fuel for ion modulation in sensitive gated OPECT biosensing. A transistor system based on poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) converted biological events associated with photosensitive gate achieving nearly a thousand-fold higher current gain at zero bias voltage. This work quantified the target DEHP by aptamer-specific induction of CRISPR-Cas13a trans-cutting activity with target-dependent rolling circle amplification as the signal amplification unit, and incorporated the signal changes strategy of biocatalytic precipitation and TMB color development. Combining OPECT with the auxiliary validation of colorimetry (CM), high sensitivity and accurate detection of DEHP were achieved with a linear range of 0.1 pM to 200 pM and a minimum detection limit of 0.02 pM. This study not only provides a new method for the detection of DEHP, but also offers a promising prospect for the gating and application of the unique OPECT.
Collapse
Affiliation(s)
- Haowei Zhang
- College of Chemistry and Material Science, Food Safety Analysis and Test Engineering Technology Research Center of Shandong Province, Shandong Agricultural University, Tai'an, Shandong 271018, PR China
| | - Miao Zhang
- College of Chemistry and Material Science, Food Safety Analysis and Test Engineering Technology Research Center of Shandong Province, Shandong Agricultural University, Tai'an, Shandong 271018, PR China
| | - Yunlei Zhou
- College of Chemistry and Material Science, Food Safety Analysis and Test Engineering Technology Research Center of Shandong Province, Shandong Agricultural University, Tai'an, Shandong 271018, PR China.
| | - Zhen Qiao
- College of Chemistry and Material Science, Food Safety Analysis and Test Engineering Technology Research Center of Shandong Province, Shandong Agricultural University, Tai'an, Shandong 271018, PR China
| | - Lanlan Gao
- College of Chemistry and Material Science, Food Safety Analysis and Test Engineering Technology Research Center of Shandong Province, Shandong Agricultural University, Tai'an, Shandong 271018, PR China
| | - Lulu Cao
- College of Chemistry and Material Science, Food Safety Analysis and Test Engineering Technology Research Center of Shandong Province, Shandong Agricultural University, Tai'an, Shandong 271018, PR China
| | - Huanshun Yin
- College of Chemistry and Material Science, Food Safety Analysis and Test Engineering Technology Research Center of Shandong Province, Shandong Agricultural University, Tai'an, Shandong 271018, PR China.
| | - Minghui Wang
- Jiangsu Co-Innovation Center of Efficient Processing and Utilization of Forest Resources, College of Science, Nanjing Forestry University, Nanjing 210037, PR China
| |
Collapse
|
2
|
Küçük M, Osman B, Tümay Özer E. Dummy molecularly imprinted polymer-based solid-phase extraction method for the determination of some phthalate monoesters in urine by gas chromatography-mass spectrometry analysis. J Chromatogr A 2024; 1713:464532. [PMID: 38039622 DOI: 10.1016/j.chroma.2023.464532] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 11/13/2023] [Accepted: 11/24/2023] [Indexed: 12/03/2023]
Abstract
A dummy molecularly imprinted polymer-based solid-phase extraction (SPE) sorbent was used for the selective extraction of some phthalate monoesters, monoethyl phthalate (MEP), monobutyl phthalate (MnBP) and mono-(2-ethylhexyl) phthalate (MEHP) in urine prior to gas-chromatography-mass spectrometry (GC-MS) analysis. Diethyl phthalate (DEP), a phthalate ester, was successfully used as a dummy template to prepare selective sorbent for MEP, MnBP, and MEHP extraction. DEP-imprinted poly(ethylene glycol dimethacrylate N-methacryloyl-l-tryptophan methyl ester) (DPEMT) microbeads were synthesized by suspension polymerization and characterized by Fourier Transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and Brunauer Emmet Teller (BET) analysis. The critical parameters (i.e., pH, sorbent amount, ionic strength, sample volume, elution solvent) affecting the extraction performance of the DPEMT-SPE sorbent were optimized. Under optimum conditions, good linearities were obtained in the concentration range of 4 to 60 ng/mL with determination coefficients (R2) of greater than 0.9959. The developed SPE method provided low limits of detection (LOD) of 0.05-1.20 ng/mL and limits of quantification (LOQ) of 0.18-4.01 ng/mL with relative standard deviations (RSDs) of less than 8.95 % for intra- and inter-day analyses. The proposed SPE method was used to analyze phthalate monoesters in spiked urine samples, and recoveries of 97.45-109.26 % were obtained. DPEMT-SPE sorbent was reused for 15 times without any losses of performance. Consequently, a highly selective and sensitive SPE method based on a dummy molecularly imprinted polymer combined with GC-MS was successfully developed to monitor human phthalate exposure via urine samples.
Collapse
Affiliation(s)
- Melike Küçük
- Department of Chemistry, Faculty of Arts and Science, Bursa Uludag University, Görükle, Bursa 16059, Turkey
| | - Bilgen Osman
- Department of Chemistry, Faculty of Arts and Science, Bursa Uludag University, Görükle, Bursa 16059, Turkey
| | - Elif Tümay Özer
- Department of Chemistry, Faculty of Arts and Science, Bursa Uludag University, Görükle, Bursa 16059, Turkey.
| |
Collapse
|
3
|
Liu Y, Deng Y, Liao D, Han Y, Wang Q, Guo Y, Bai H, Dong C, Fan L. Nickel hexacyanoferrate nanoparticle-decorated 3D rGO composites-based electrochemical sensing platform for detection of di-2-ethylhexyl phthalate. Mikrochim Acta 2023; 190:107. [PMID: 36854982 DOI: 10.1007/s00604-023-05670-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Accepted: 01/20/2023] [Indexed: 03/02/2023]
Abstract
A label-free and efficient electrochemical (EC) sensing platform for di-2-ethylhexyl phthalate (DEHP) was developed based on in situ probe nickel hexacyanoferrate nanoparticle (NiHCF NP)-decorated three-dimensional reduced graphene oxide (3D rGO) composites. NiHCF NPs in the composites as an in situ probe show a pair of well-defined peaks with good reversibility and stability. Coupling 3D rGO with NiHCF NPs not only improved the electron transfer capability of NiHCF NPs but also provided more sites for aptamer immobilization. The synthesized NiHCF NP-decorated 3D rGO composites were used to act as a substrate for the immobilization of anti-DEHP aptamer by the covalent bonding method. The designed EC sensing platform displays excellent sensing performance for DEHP with a low detection limit of 3.64 pg/L, and a linear working range of 0.01 - 1000 ng/L. The application of the sensing platform to actual environmental samples was studied and satisfactory results were obtained. Thus, the proposed EC sensing platform would provide a potential tool for efficient detection of pollutants in the environment.
Collapse
Affiliation(s)
- Yuyao Liu
- Institute of Environmental Science, College of Chemistry and Chemical Engineering, Shanxi University, Shanxi, 030006, Taiyuan, People's Republic of China
| | - Yuan Deng
- Institute of Environmental Science, College of Chemistry and Chemical Engineering, Shanxi University, Shanxi, 030006, Taiyuan, People's Republic of China
| | - Dongyun Liao
- Institute of Environmental Science, College of Chemistry and Chemical Engineering, Shanxi University, Shanxi, 030006, Taiyuan, People's Republic of China
| | - Yujie Han
- Institute of Environmental Science, College of Chemistry and Chemical Engineering, Shanxi University, Shanxi, 030006, Taiyuan, People's Republic of China
| | - Qiang Wang
- State Key Laboratory of Coal Conversion, Institute of Coal Chemistry, Chinese Academy of Sciences, Taiyuan, 030001, Shanxi, China
| | - Yujing Guo
- Institute of Environmental Science, College of Chemistry and Chemical Engineering, Shanxi University, Shanxi, 030006, Taiyuan, People's Republic of China.
| | - Hongcun Bai
- State Key Laboratory of High-Efficiency Utilization of Coal and Green Chemical Engineering, Ningxia University, Yinchuan, 750021, Ningxia, China
| | - Chuan Dong
- Institute of Environmental Science, College of Chemistry and Chemical Engineering, Shanxi University, Shanxi, 030006, Taiyuan, People's Republic of China
| | - Lifang Fan
- Institute of Environmental Science, College of Chemistry and Chemical Engineering, Shanxi University, Shanxi, 030006, Taiyuan, People's Republic of China.
| |
Collapse
|
4
|
Deng Y, Yan W, Guo Y, Wang Q, Bi Y, Dong C, Fan L. Highly sensitive and selective photoelectrochemical aptasensing of di-2-ethylhexyl phthalate based on graphene quantum dots decorated TiO 2 nanotube arrays. JOURNAL OF HAZARDOUS MATERIALS 2022; 426:128107. [PMID: 34971987 DOI: 10.1016/j.jhazmat.2021.128107] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Revised: 11/29/2021] [Accepted: 12/16/2021] [Indexed: 06/14/2023]
Abstract
A photoelectrochemical (PEC) sensing platform for di-2-ethylhexyl phthalate (DEHP) was constructed using graphene quantum dots decorated TiO2 nanotube arrays (GQDs-decorated TiO2 NTs) as the transducer species and the anti-DEHP aptamer as the biological recognition element. GQDs were synthesized using the alkali-mediated hydrothermal method, and then anchored onto the TiO2 NTs uniformly and intimately via pronounced electrostatic interaction. Coupling GQDs with TiO2 NTs not only enhanced visible-light absorption, but promoted charge separation and transportation, exhibiting excellent photocurrent response, and PEC activity. Various means were conducted to explore morphologies, optical, structural and PEC properties of the materials. As an identification unit, the anti-DEHP aptamer molecules were immobilized on GQDs-decorated TiO2 NTs using a cross-linking coupling method. The developed PEC sensing platform exhibits excellent sensing behavior for DEHP, and provides a low detection limit of 0.1 ng/L, high selectivity and stability. Meanwhile, its application in real environmental samples was evaluated and satisfying results were achieved. Thus, the established sensing platform provides a promising tool to detect DEHP in the environment.
Collapse
Affiliation(s)
- Yuan Deng
- Institute of Environmental Science, College of Chemistry and Chemical Engineering, Shanxi University, Taiyuan, Shanxi 030006, PR China
| | - Wenjun Yan
- Analytical Instrumentation Center and State Key Laboratory of Coal Conversion, Institute of Coal Chemistry, CAS, Taiyuan 030001, PR China
| | - Yujing Guo
- Institute of Environmental Science, College of Chemistry and Chemical Engineering, Shanxi University, Taiyuan, Shanxi 030006, PR China
| | - Qiang Wang
- Analytical Instrumentation Center and State Key Laboratory of Coal Conversion, Institute of Coal Chemistry, CAS, Taiyuan 030001, PR China
| | - Yingpu Bi
- State Key Laboratory for Oxo Synthesis & Selective Oxidation, Lanzhou Institute of Chemical Physics, CAS, Lanzhou 730000, PR China
| | - Chuan Dong
- Institute of Environmental Science, College of Chemistry and Chemical Engineering, Shanxi University, Taiyuan, Shanxi 030006, PR China.
| | - Lifang Fan
- Institute of Environmental Science, College of Chemistry and Chemical Engineering, Shanxi University, Taiyuan, Shanxi 030006, PR China.
| |
Collapse
|
5
|
Huang S, Qi Z, Ma S, Li G, Long C, Yu Y. A critical review on human internal exposure of phthalate metabolites and the associated health risks. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2021; 279:116941. [PMID: 33756240 DOI: 10.1016/j.envpol.2021.116941] [Citation(s) in RCA: 68] [Impact Index Per Article: 22.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Revised: 03/02/2021] [Accepted: 03/03/2021] [Indexed: 06/12/2023]
Abstract
Phthalates (PAEs) are popular synthetic chemicals used as plasticizers and solvents for various products, such as polyvinyl chloride or personal care products. Human exposure to PAEs is associated with various diseases, resulting in PAE biomonitoring in humans. Inhalation, dietary ingestion, and dermal absorption are the major human exposure routes. However, estimating the actual exposure dose of PAEs via an external route is difficult. As a result, estimation by internal exposure has become the popular analytical methods to determine the concentrations of phthalate metabolites (mPAEs) in human matrices (such as urine, serum, breast milk, hair, and nails). The various exposure sources and patterns result in different composition profiles of PAEs in biomatrices, which vary from country to country. Nevertheless, the mPAEs of diethyl phthalate (DEP), di-n-butyl phthalate (DnBP), di-iso-butyl phthalate (DiBP), and di-(2-ethylhexyl) phthalate (DEHP) are predominant in the urine. These mPAEs have greater potential health risks for humans. Children have been observed to exhibit higher exposure risks to several mPAEs than adults. Besides age, other influencing factors for phthalate exposure are gender, jobs, and residential areas. Although many studies have reported biological monitoring of PAEs, only a few reviews that adequately summarized the reports are available. The current review appraised available studies on mPAE quantitation in human biomatrices and estimated the dose and health risks of phthalate exposure. While some countries lack biomonitoring data, some countries' data do not reflect the current PAE exposure. Thence, future studies should involve frequent PAE biomonitoring to accurately estimate human exposure to PAEs, which will contribute to health risk assessments of human exposure to PAEs. Such would aid the formulation of corresponding regulations and restrictions by the government.
Collapse
Affiliation(s)
- Senyuan Huang
- Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, School of Environmental Science and Engineering, Institute of Environmental Health and Pollution Control, Guangdong University of Technology, Guangzhou, 510006, PR China; Guangdong-Hong Kong-Macao Joint Laboratory for Contaminants Exposure and Health, Guangzhou, 510006, PR China
| | - Zenghua Qi
- Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, School of Environmental Science and Engineering, Institute of Environmental Health and Pollution Control, Guangdong University of Technology, Guangzhou, 510006, PR China; Guangdong-Hong Kong-Macao Joint Laboratory for Contaminants Exposure and Health, Guangzhou, 510006, PR China
| | - Shengtao Ma
- Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, School of Environmental Science and Engineering, Institute of Environmental Health and Pollution Control, Guangdong University of Technology, Guangzhou, 510006, PR China; Guangdong-Hong Kong-Macao Joint Laboratory for Contaminants Exposure and Health, Guangzhou, 510006, PR China; Synergy Innovation Institute of GDUT, Shantou, 515041, China
| | - Guiying Li
- Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, School of Environmental Science and Engineering, Institute of Environmental Health and Pollution Control, Guangdong University of Technology, Guangzhou, 510006, PR China; Guangdong-Hong Kong-Macao Joint Laboratory for Contaminants Exposure and Health, Guangzhou, 510006, PR China
| | - Chaoyang Long
- Center for Disease Prevention and Control of Guangdong Province, Guangzhou, 510430, PR China
| | - Yingxin Yu
- Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, School of Environmental Science and Engineering, Institute of Environmental Health and Pollution Control, Guangdong University of Technology, Guangzhou, 510006, PR China; Guangdong-Hong Kong-Macao Joint Laboratory for Contaminants Exposure and Health, Guangzhou, 510006, PR China.
| |
Collapse
|
6
|
Daryanavard SM, Zolfaghari H, Abdel-Rehim A, Abdel-Rehim M. Recent applications of microextraction sample preparation techniques in biological samples analysis. Biomed Chromatogr 2021; 35:e5105. [PMID: 33660303 DOI: 10.1002/bmc.5105] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 01/26/2021] [Accepted: 02/05/2021] [Indexed: 12/11/2022]
Abstract
Analysis of biological samples is affected by interfering substances with chemical properties similar to those of the target analytes, such as drugs. Biological samples such as whole blood, plasma, serum, urine and saliva must be properly processed for separation, purification, enrichment and chemical modification to meet the requirements of the analytical instruments. This causes the sample preparation stage to be of undeniable importance in the analysis of such samples through methods such as microextraction techniques. The scope of this review will cover a comprehensive summary of available literature data on microextraction techniques playing a key role for analytical purposes, methods of their implementation in common biological samples, and finally, the most recent examples of application of microextraction techniques in preconcentration of analytes from urine, blood and saliva samples. The objectives and merits of each microextration technique are carefully described in detail with respect to the nature of the biological samples. This review presents the most recent and innovative work published on microextraction application in common biological samples, mostly focused on original studies reported from 2017 to date. The main sections of this review comprise an introduction to the microextraction techniques supported by recent application studies involving quantitative and qualitative results and summaries of the most significant, recently published applications of microextracion methods in biological samples. This article considers recent applications of several microextraction techniques in the field of sample preparation for biological samples including urine, blood and saliva, with consideration for extraction techniques, sample preparation and instrumental detection systems.
Collapse
Affiliation(s)
| | - Hesane Zolfaghari
- Department of Chemistry, Faculty of Science, University of Hormozgan, Bandar-Abbas, Iran
| | - Abbi Abdel-Rehim
- Department of Chemical Engineering and Biotechnology, Cambridge University, Cambridge, UK
| | - Mohamed Abdel-Rehim
- Functional Materials Division, Department of Applied Physics, School of Engineering Sciences, KTH Royal Institute of Technology, Stockholm, Sweden.,Department of Clinical Neuroscience, Centre for Psychiatry Research, Karolinska Institutet, Solna, Sweden
| |
Collapse
|
7
|
Arpna Kumari, Rajinder Kaur. Chromatographic Methods for the Determination of Phthalic Acid Esters in Different Samples. JOURNAL OF ANALYTICAL CHEMISTRY 2021. [DOI: 10.1134/s1061934821010056] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
8
|
A comprehensive review on application of the syringe in liquid- and solid-phase microextraction methods. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2021. [DOI: 10.1007/s13738-020-02025-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
9
|
Huelsmann RD, Will C, Carasek E. Novel strategy for disposable pipette extraction (DPX): Low-cost Parallel-DPX for determination of phthalate migration from common plastic materials to saliva simulant with GC-MS. Talanta 2021; 221:121443. [PMID: 33076068 DOI: 10.1016/j.talanta.2020.121443] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Revised: 07/16/2020] [Accepted: 07/20/2020] [Indexed: 11/28/2022]
Abstract
In widespread use in commercial products as plasticizers, phthalic acid esters (phthalates) have worried researchers and society in general, given the negative impacts on living organisms, especially human health. Since they are not chemically linked to the polymeric matrix, their migration is evident for samples that come into contact with plastics that contain them, such as water, food and saliva. In this work, a new strategy is described, named parallel-disposable pipette extraction (Pa-DPX), in a fast, efficient and robust analytical method using five simultaneous extractions for the determination of migration of 6 phthalates from common plastic materials (children's toys, school supplies, dog toys and oral contact items) to saliva simulant, using gas chromatography-mass spectrometry (GC-MS). The optimized conditions were 5 extraction cycles with 1600 μL of saliva simulant and desorption with 200 μL of ethyl acetate using 5 cycles with the same aliquot. The calibration curves resulted in determination coefficients higher than 0.9915, limits of detection at 1.5 μg L-1, and the quantification limits were 5.0 μg L-1. Excellent results were obtained for repeatability (relative standard deviation ranging from 8.7% to 20.1% for 5 μg L-1) and intermediate precision, varying the day of analyses (7.9%-16.2%). The analyte recovery ranged from 75% to 114% for two different samples, in four different levels of concentration. The Pa-DPX-GC-MS method was successfully applied to determine the migration of PAE from 21 samples. At least one PAE was detected in 81% of samples, and di-n-octyl phthalate was found in higher concentration, achieving the migration of almost 30 μg per g of sample.
Collapse
Affiliation(s)
| | - Camila Will
- Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis, 88040900, Brazil
| | - Eduardo Carasek
- Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis, 88040900, Brazil.
| |
Collapse
|
10
|
Zakharkiv I, Zui M, Zaitsev V. Determination of Phthalate Esters in Water and Liquid Pharmaceutical Samples by Dispersive Liquid-Liquid Microextraction (DLLME) and Gas Chromatography with Flame Ionization Detection (GC-FID). ANAL LETT 2020. [DOI: 10.1080/00032719.2019.1711384] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Affiliation(s)
- Igor Zakharkiv
- Department of Chemistry, Taras Shevchenko National University of Kyiv, Kyiv, Ukraine
| | - Maryna Zui
- Department of Chemistry, Taras Shevchenko National University of Kyiv, Kyiv, Ukraine
| | - Vladimir Zaitsev
- Department of Chemistry, Pontifícia Universidade Católica do Rio de Janeiro, Brazil, Rio de Janeiro, RJ, Brasil
| |
Collapse
|
11
|
Tu D, Garza JT, Coté GL. A SERS aptasensor for sensitive and selective detection of bis(2-ethylhexyl) phthalate. RSC Adv 2019; 9:2618-2625. [PMID: 31681474 PMCID: PMC6823992 DOI: 10.1039/c8ra09230c] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Bis(2-ethylhexyl)phthalate (DEHP) is an endocrine disruptor commonly present in plastic products, such as PVC tubes and water bottles. In this work, a surface enhanced Raman spectroscopy (SERS) based aptasensor was developed and utilized for rapid, easy, sensitive, and specific detection of trace DEHP. A DEHP aptamer was immobilized on magnetic particles. Raman reporter molecule conjugated silver nanoparticles were clustered and coated with silica to provide a stable SERS signal. The SERS silica particle was then functionalized with 1,2,4-benzenetricarboxylic acid 1,2-bis(2-ethylhexyl) ester to increase its affinity to the DEHP aptamer. In the presence of a sample with DEHP, the high-affinity SERS silica particle competes with the DEHP molecule to bind with the aptamer on the magnetic particle. By measuring the signal of free SERS silica particles in the supernatant after magnetic separation, the concentration of DEHP in the sample was quantitatively determined. The developed DEHP aptasensor had a detection range from 0.008 to 182 nM and a limit of detection (LOD) of 8 pM. The aptasensor also showed high selectivity when exposed to interferents with analogous structures. The aptasensor was successfully tested for the detection of DEHP spiked in tap water, bottled water, and a carbonate beverage. The developed SERS-based aptasensor provides a rapid, sensitive, and easy-to-use method for the quantitative detection of DEHP in environmental and food analysis. This paper reports a SERS aptasensor developed to detect DEHP at relevant ranges with ultrasensitive performance and good selectivity.![]()
Collapse
Affiliation(s)
- Dandan Tu
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Javier T Garza
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States.,Center for Remote Health Technologies & Systems, Texas A&M Engineering Experiment Station, College Station, Texas 77843, United States
| | - Gerard L Coté
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States.,Center for Remote Health Technologies & Systems, Texas A&M Engineering Experiment Station, College Station, Texas 77843, United States
| |
Collapse
|