1
|
Ben Abdallah C, Sekundo W, Ladewig MS, Handzel DM. Intraocular pressure before and after capsulorhexis using two viscoelastic substances and two surgical approaches in enucleated porcine eyes. Int J Ophthalmol 2024; 17:1156-1160. [PMID: 38895666 PMCID: PMC11144763 DOI: 10.18240/ijo.2024.06.22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Accepted: 03/18/2024] [Indexed: 06/21/2024] Open
Abstract
AIM To investigate the influence of ophthalmic viscoelastic devices (OVDs) and different surgical approaches on the intraocular pressure (IOP) before and after creation of the curvilinear circular capsulorhexis (CCC) as a measure for anterior chamber stability during this maneuver. METHODS Prospective experimental WetLab study carried out on enucleated porcine eyes. IOP was measured before and after CCC with the iCare Rebound tonometer (iCare ic200; iCare Finland Oy, Vantaa, Finland). The OVDs used were a cohesive one [Z-Hyalin, Carl Zeiss Meditec AG, Germany; hyaluronic acid (HA)] and a dispersive [Z-Celcoat, Carl Zeiss Meditec AG, Germany; hydroxy propylmethylcellulosis (HPMC)]. The CCC was created using Utrata forceps or 23 g microforceps in different combinations with the OVDs. RESULTS Using the Utrata forceps the IOP dropped from 63.65±6.44 to 11.25±3.63 mm Hg during the CCC. The use of different OVDs made no difference. Using the 23 g microforceps the IOP dropped from 65.35±8.15 to 36.55±6.09 mm Hg. The difference between IOP drop using either Utrata forceps or 23 g microforceps was highly significant regardless of the OVD used. CONCLUSION Using the sideport for the creation of the capsulorhexis leads to a lesser drop in IOP during this maneuver compared to the main incision in enucleated porcine eyes. The use of different OVD has no significant influence on IOP drop.
Collapse
Affiliation(s)
| | - Walter Sekundo
- University Eye Hospital Philipps-University, Marburg 35043, Germany
| | - Markus S. Ladewig
- University Eye Hospital Philipps-University, Campus Fulda, Fulda 36043, Germany
| | | |
Collapse
|
2
|
Wood K, Pessach Y, Kovalyuk N, Lifshitz M, Winter H, Pikkel J. Corneal endothelial cell loss and intraocular pressure following phacoemulsification using a new viscous-cohesive ophthalmic viscosurgical device. Int Ophthalmol 2024; 44:10. [PMID: 38319386 DOI: 10.1007/s10792-024-02997-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Accepted: 10/19/2023] [Indexed: 02/07/2024]
Abstract
PURPOSE To compare results of two ophthalmic viscosurgical devices (OVDs)-Viscoat (a dispersive OVD, Alcon) and FR-Pro (a viscous-cohesive OVD, Rayner), in phacoemulsification surgery. METHODS A prospective randomized controlled study. Patients undergoing phacoemulsification were randomly assigned to receive one of the two OVDs. Exclusion criteria were age under 40, preoperative endothelial cell count (ECC) below 1,500 cells/mm2 and an eventful surgery. The primary outcome was change in ECC from baseline to postoperative month one and month three. Secondary outcomes were the difference between ECC at postoperative month one and month three, changes in IOP and occurrence of an IOP spike ≥ 30 mmHg after surgery. RESULTS The study included 84 eyes-43 in the Viscoat group and 41 in the FR-Pro group. Mean cell density loss at month one and month three was 17.0 and 19.2%, respectively, for the Viscoat group and 18.4 and 18.8%, respectively, for the FR-Pro group, with no statistically significant difference between the groups (p = 0.772 and p = 0.671, respectively). The mean ECC difference between the month one and month three visits was 50.5 cells/mm2 and was not statistically significant (p = 0.285). One eye in each group had an IOP spike ≥ 30 mmHg, both normalized by postoperative week one. CONCLUSIONS Viscoat and FR-Pro have comparable results following phacoemulsification surgery, suggesting that while FR-Pro is not a dispersive OVD, its endothelial cell protection may be comparable to one, perhaps due to the addition of sorbitol. Furthermore, a one-month follow-up of ECC seems sufficient in such trials.
Collapse
Affiliation(s)
- Keren Wood
- Department of Ophthalmology, Samson Assuta Ashdod University Hospital, Ha-Refu'a St 7, 7747629, Ashdod, Israel.
| | - Yuval Pessach
- Department of Ophthalmology, Samson Assuta Ashdod University Hospital, Ha-Refu'a St 7, 7747629, Ashdod, Israel
| | - Natalya Kovalyuk
- Department of Ophthalmology, Samson Assuta Ashdod University Hospital, Ha-Refu'a St 7, 7747629, Ashdod, Israel
| | - Michal Lifshitz
- Department of Ophthalmology, Samson Assuta Ashdod University Hospital, Ha-Refu'a St 7, 7747629, Ashdod, Israel
| | - Halit Winter
- Department of Ophthalmology, Samson Assuta Ashdod University Hospital, Ha-Refu'a St 7, 7747629, Ashdod, Israel
| | - Joseph Pikkel
- Department of Ophthalmology, Samson Assuta Ashdod University Hospital, Ha-Refu'a St 7, 7747629, Ashdod, Israel
| |
Collapse
|
3
|
LoBue SA, Rizzuti AE, Martin CR, Albear SA, Gill ES, Shelby CL, Coleman WT, Smith EF. Preventing the Argentinian flag sign and managing anterior capsular tears: A review. Indian J Ophthalmol 2024; 72:162-173. [PMID: 38273682 PMCID: PMC10941923 DOI: 10.4103/ijo.ijo_1418_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 10/09/2023] [Accepted: 10/25/2023] [Indexed: 01/27/2024] Open
Abstract
The Argentinian flag sign (AFS) is a feared complication during cataract extraction. Intralenticular pressures, especially excessive posterior pressure, have been identified as potential mechanisms for capsular stress and tearing associated with AFS. Capsular tension is created by positive intralenticular pressures, which cause the irido-lens diaphragm to move anteriorly once the manual capsulorhexis has been initiated. This tension can cause inadvertent tears that self-propagate to the lens equator, causing an AFS, among other intraoperative complications. Thus, this review highlights the importance of identifying intumescent cataracts as well as a combination of techniques to relieve intracapsular pressures needed to prevent AFS. However, some instances of anterior capsular tears are unavoidable. Therefore, focus will also be placed on techniques during cataract extraction used to manage anterior capsular tears, mitigating extension to the posterior capsule.
Collapse
Affiliation(s)
- Stephen A LoBue
- Department of Ophthalmology, SUNY Downstate Medical Center, Brooklyn, NY, USA
- Department of Ophthalmology, Willis-Knighton Medical Center, Shreveport, LA, USA
| | - Allison E Rizzuti
- Department of Ophthalmology, SUNY Downstate Medical Center, Brooklyn, NY, USA
| | - Curtis R Martin
- Department of Ophthalmology, Willis-Knighton Medical Center, Shreveport, LA, USA
| | - Sinan A Albear
- Department of Ophthalmology, SUNY Downstate Medical Center, Brooklyn, NY, USA
| | - Ekjyot S Gill
- Department of Ophthalmology, SUNY Downstate Medical Center, Brooklyn, NY, USA
- Department of Ophthalmology, UCLA Stein Eye Institute, Los Angeles, CA, USA
| | - Christopher L Shelby
- Department of Ophthalmology, Willis-Knighton Medical Center, Shreveport, LA, USA
| | - Wyche T Coleman
- Department of Ophthalmology, Willis-Knighton Medical Center, Shreveport, LA, USA
| | - Edward F Smith
- Department of Ophthalmology, SUNY Downstate Medical Center, Brooklyn, NY, USA
| |
Collapse
|
4
|
Naujokaitis T, Auffarth GU, Łabuz G, Khoramnia R. Endothelial Cell Loss in Patients with Phakic Intraocular Lenses. Klin Monbl Augenheilkd 2024. [PMID: 38242162 DOI: 10.1055/a-2209-5251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2024]
Abstract
Although the safety of phakic intraocular lenses (pIOLs) has been continuously improved over 70-years of development, high endothelial cell losses can occur even with current pIOL models. Numerous studies have demonstrated that the distance of a pIOL to the corneal endothelium plays a crucial role in the extent of endothelial cell loss. For this reason alone, higher endothelial cell loss tends to be observed with anterior chamber lenses than with posterior chamber lenses. Adequate preoperative anterior chamber depth is essential, at least for iris-fixed pIOLs, in order to ensure a safe distance from the endothelium. However, the anterior chamber becomes shallower with age and therefore it may be useful to consider patient age in the safety criteria. Although endothelial cell loss is generally low with current pIOL models, regular monitoring of the endothelial cell density remains essential due to large interindividual differences in patients with pIOLs. If the endothelial cell loss is greater than expected and the follow-up visits confirm the trend, the pIOL should be explanted without delay. The endothelial reserve should be considered on an individual basis by taking into account patient age, physiological endothelial cell loss, and loss due to further surgery. With careful indication and long-term patient care, pIOLs remain a safe treatment option.
Collapse
Affiliation(s)
- Tadas Naujokaitis
- International Vision Correction Research Centre (IVCRC) und David J Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, Deutschland
| | - Gerd U Auffarth
- International Vision Correction Research Centre (IVCRC) und David J Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, Deutschland
| | - Grzegorz Łabuz
- International Vision Correction Research Centre (IVCRC) und David J Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, Deutschland
| | - Ramin Khoramnia
- International Vision Correction Research Centre (IVCRC) und David J Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, Deutschland
| |
Collapse
|
5
|
Jensen NR, Ungricht EL, Harris JT, Zaugg B, Barlow WR, Murri MS, Olson RJ, Pettey JH. Temperature Change of Ophthalmic Viscosurgical Devices in a Bi-Chamber Set-Up at a Flow of 0 and 20mL/min. Clin Ophthalmol 2023; 17:555-560. [PMID: 36798796 PMCID: PMC9926926 DOI: 10.2147/opth.s389136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Accepted: 01/10/2023] [Indexed: 02/11/2023] Open
Abstract
Purpose To understand the role of ophthalmic viscosurgical devices (OVDs) in corneal incision contracture (CIC). Specifically, the aim was to evaluate with the tip of the phacoemulsification needle free of OVD, how various OVDs near the tip and sleeve may transmit thermal energy to the incision site. Methods A small chamber was filled with balanced saline solution (BSS), and a thin membrane was placed on the surface. OVD was placed atop the membrane. A temperature probe was placed in the OVD, while the handpiece pierced the membrane. The experiment was run both with and without flow and vacuum. Temperature measurements were gathered for each of the OVDs at four separate time points at 0 and 20mL/min flow. Results As expected, there was a more pronounced temperature increase in all test groups with no fluid flow. While the temperature increase was not significantly different from BSS for any of the OVDs tested at either 0 or 20mL/min, Viscoat showed the most variable results at both flow settings. Conclusion As long as the phaco tip is not in OVD, residual OVD near the incision is not exothermic and so not an additional risk for CIC.
Collapse
Grants
- T35 EY026511 NEI NIH HHS
- UL1 TR002529 NCATS NIH HHS
- Research to Prevent Blindness, Inc., New York, New York, USA, to the Department of Ophthalmology and Visual Sciences, University of Utah, Salt Lake City, Utah, USA. Dr. Harris and Dr. Ungricht were awarded the NIH Ruth L. Kirschstein National Research Service Award (NRS) institutional training grant
- the Indiana Clinical and Translational Sciences Institute
- the National Institutes of Health, National Center for Advancing Translational Sciences, Clinical and Translational Sciences Award
Collapse
Affiliation(s)
- Nathan R Jensen
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
- University of Utah School of Medicine, Salt Lake City, UT, 84132, USA
| | - Emilie L Ungricht
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
- University of Utah School of Medicine, Salt Lake City, UT, 84132, USA
| | - Jacob T Harris
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
- University of Utah School of Medicine, Salt Lake City, UT, 84132, USA
| | - Brian Zaugg
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
| | - William R Barlow
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
| | - Michael S Murri
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
| | - Randall J Olson
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
| | - Jeff H Pettey
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
| |
Collapse
|
6
|
Auffarth GU, Schickhardt SK, Fang H, Wang Q, Khoramnia R, Yildirim TM. Ophthalmic viscosurgical device interaction with two hydrophobic acrylic intraocular lenses of different equilibrium water content. Sci Rep 2022; 12:14563. [PMID: 36028543 PMCID: PMC9418328 DOI: 10.1038/s41598-022-18813-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2022] [Accepted: 08/19/2022] [Indexed: 11/09/2022] Open
Abstract
Ophthalmic viscosurgical device (OVD) is used during intraocular surgery to protect ocular tissue. It requires complete removal from the eye by the end of surgery to avoid postoperative complications. This study compares the interaction of a cohesive OVD with two different intraocular lenses (IOLs) of different equilibrium water content. In this laboratory study on porcine cadaver eyes, the capsular bags and anterior chambers of each eye were filled with fluorescein-stained OVD. Following implantation of 10 IOLs each of Clareon CNA0T0 and AcrySof SN60WF (Alcon Laboratory, Fort Worth, USA) IOLs, the OVD was removed using the irrigation/aspiration mode. The OVD removal was timed and differences between the both IOL groups were compared. OVD removal time ranged from 18 to 40 s (mean ± SD, 26.4 ± 6.8 s) and from 16 to 39 s (mean ± SD, 23.6 ± 6.6 s) for eyes implanted with a CNA0T0 and a SN60WF IOL, respectively, without a statistically significant difference between the groups, P > 0.05. Cohesive OVD removal times were similar between the CNA0T0 and SN60WF groups. Surgeons should experience no differences regarding the interaction between cohesive OVDs and IOLs made from the new Clareon material compared to the established AcrySof material.
Collapse
Affiliation(s)
- Gerd U Auffarth
- The David J Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, 69120, Heidelberg, Germany.
| | - Sonja K Schickhardt
- The David J Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, 69120, Heidelberg, Germany
| | - Hui Fang
- The David J Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, 69120, Heidelberg, Germany
| | - Qiang Wang
- The David J Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, 69120, Heidelberg, Germany.,Department of Ophthalmology, Third Affiliated Hospital, Wenzhou Medical University, Rui'an, 325200, Zhejiang, China
| | - Ramin Khoramnia
- The David J Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, 69120, Heidelberg, Germany
| | - Timur M Yildirim
- The David J Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, 69120, Heidelberg, Germany
| |
Collapse
|
7
|
Vaiciuliene R, Rylskyte N, Baguzyte G, Jasinskas V. Risk factors for fluctuations in corneal endothelial cell density (Review). Exp Ther Med 2022; 23:129. [PMID: 34970352 PMCID: PMC8713183 DOI: 10.3892/etm.2021.11052] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 10/29/2021] [Indexed: 12/17/2022] Open
Abstract
The cornea is a transparent, avascular and abundantly innervated tissue through which light rays are transmitted to the retina. The innermost layer of the cornea, also known as the endothelium, consists of a single layer of polygonal endothelial cells that serve an important role in preserving corneal transparency and hydration. The average corneal endothelial cell density (ECD) is the highest at birth (~3,000 cells/mm2), which then decrease to ~2,500 cells/mm2 at adulthood. These endothelial cells have limited regenerative potential and the minimum (critical) ECD required to maintain the pumping function of the endothelium is 400-500 cells/mm2. ECD < the critical value can result in decreased corneal transparency, development of corneal edema and reduced visual acuity. The condition of the corneal endothelium can be influenced by a number of factors, including systemic diseases, such as diabetes or atherosclerosis, eye diseases, such as uveitis or dry eye disease (DED) and therapeutic ophthalmological interventions. The aim of the present article is to review the impact of the most common systemic disorders (pseudoexfoliation syndrome, diabetes mellitus, cardiovascular disease), eye diseases (DED, uveitis, glaucoma, intraocular lens dislocation) and widely performed ophthalmic interventions (cataract surgery, intraocular pressure-lowering surgeries) on corneal ECD.
Collapse
Affiliation(s)
- Renata Vaiciuliene
- Department of Ophthalmology, Medical Academy, Lithuanian University of Health Sciences, LT-50161 Kaunas, Lithuania
| | - Neda Rylskyte
- Faculty of Medicine, Lithuanian University of Health Sciences, LT-44307 Kaunas, Lithuania
| | - Gabija Baguzyte
- Department of Ophthalmology, Medical Academy, Lithuanian University of Health Sciences, LT-50161 Kaunas, Lithuania
| | - Vytautas Jasinskas
- Department of Ophthalmology, Medical Academy, Lithuanian University of Health Sciences, LT-50161 Kaunas, Lithuania
| |
Collapse
|
8
|
Moshirfar M, Huynh R, Ellis JH. Cataract surgery and intraocular lens placement in patients with Fuchs corneal dystrophy: a review of the current literature. Curr Opin Ophthalmol 2022; 33:21-27. [PMID: 34743088 DOI: 10.1097/icu.0000000000000816] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE OF REVIEW Late-onset Fuchs endothelial corneal dystrophy (FECD) is seen in approximately 4% of individuals over the age of 40. With the growing population of adults over the age of 65, ophthalmologists need to be aware of the preoperative, perioperative, and postoperative considerations involved in cataract surgery in Fuchs patients. RECENT FINDINGS Management of cataract patients with FECD requires preoperative assessment of endothelial cell size, density, and morphology. Considerations for perioperative endothelial cell loss include patients with hyperopia and shallow anterior chambers, phacoemulsification technique, transfer of ultrasonic energy to the cornea, corneal-protective perioperative agents, as well as thermal and mechanical damage. SUMMARY Ophthalmologists performing cataract surgery on patients with FECD must carefully consider the risks of endothelial cell loss during surgery and minimize the risk of corneal decompensation after surgery. Preoperative management should evaluate the severity of the FECD as well as individual factors such as cataract density, the health and thickness of the cornea, and the anterior chamber depth. Perioperative techniques, adjustments to biometry calculations, and intraocular lens (IOL) selection may help optimize visual outcomes and recovery time.
Collapse
Affiliation(s)
- Majid Moshirfar
- Hoopes Vision Research Center, Hoopes Vision, Draper, Utah, USA
- John A. Moran Eye Center, Department of Ophthalmology and Visual Sciences, University of Utah, Salt Lake City, Utah, USA
- Utah Lions Eye Bank, Murray, Utah, USA
| | - Rachel Huynh
- University of Utah School of Medicine, Salt Lake City, Utah, USA
| | - James H Ellis
- University of Utah School of Medicine, Salt Lake City, Utah, USA
| |
Collapse
|
9
|
Borkenstein AF, Borkenstein EM, Malyugin B. Ophthalmic Viscosurgical Devices (OVDs) in Challenging Cases: a Review. Ophthalmol Ther 2021; 10:831-843. [PMID: 34617249 PMCID: PMC8589875 DOI: 10.1007/s40123-021-00403-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Accepted: 09/27/2021] [Indexed: 11/27/2022] Open
Abstract
Ophthalmic viscoelastic devices (OVDs) are currently used in cataract surgery and have significantly improved the safety and effectiveness of this surgical procedure. OVDs are classified according to the zero-shear viscosity and the cohesion-dispersion index in cohesive, dispersive, and viscoadaptives. OVDs create and maintain anterior chamber depth and visibility, protecting the corneal endothelium and other intraocular tissues during surgery. The selection of the most adequate OVD is especially relevant when performing cataract surgery in challenging cases, such as in hard, mature cataracts, flat anterior chamber, pseudoexfoliation syndrome, intraoperative floppy iris syndrome, or glaucoma surgery. In such cases, OVD is crucial for facilitating the surgical procedure and the associated minimal complication rate. The use of a combination of OVDs (soft-shell technique and modifications), the use of blue-colored OVDs, and the combination of sodium hyaluronate with lidocaine have also been described as useful tools in some of these challenging cases.
Collapse
Affiliation(s)
- Andreas F Borkenstein
- Borkenstein and Borkenstein, Private Practice at Privatklinik Kreuzschwestern, Kreuzgasse 35, 8010, Graz, Austria.
| | - Eva-Maria Borkenstein
- Borkenstein and Borkenstein, Private Practice at Privatklinik Kreuzschwestern, Kreuzgasse 35, 8010, Graz, Austria
| | - Boris Malyugin
- Department of Cataract and Implant Surgery, S. Fyodorov Eye Microsurgery Complex State Institution, Beskudnikovsky Boulevard 59A, Moscow, 127486, Russia
| |
Collapse
|
10
|
Ghoneim EM. Modified capsulorhexis for fiuid-filled mature cataracts. MEDICAL HYPOTHESIS, DISCOVERY & INNOVATION OPHTHALMOLOGY JOURNAL 2021; 10:59-66. [PMID: 37641610 PMCID: PMC10460229 DOI: 10.51329/mehdioptometry1422] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/31/2023]
Abstract
Background The aim of this study was to develop a modified capsulorhexis technique featuring a new maneuver for the removal of subcortical fluid in fluid-filled mature cataracts to avoid high intralenticular pressure. Methods This prospective interventional study included 33 eyes with mature cataracts and evidence of subcapsular fluid spaces by slit lamp examination. For each patient, 20% mannitol was administered intravenously according to the bodyweight 1 h preoperatively. Under peribulbar anesthesia, a 2.2-mm main incision was made, and the anterior chamber was filled with a dispersive ophthalmic viscosurgical device. Using a bent-tip cystotome, a 2-mm curved incision was made in the center of the anterior capsule, which released subcortical fluid and was drained through compression of the posterior lip of the main incision using a spatula. Then, fine gentle milking in all quadrants around the puncture on the anterior lens capsule from the periphery toward the site of puncture using the blunt-edged spatula further assists drainage of subcortical fluid and breaks fine septa inside the lens to remove fluid from intralenticular fluid pocket collections. Results The study included 15 (45.5%) men and 18 (54.5%) women with a mean (standard deviation [SD]) of age of 63.2 (5.33) and 64.4 (6.21) years, respectively. The modified capsulorhexis technique was performed for 33 intumescent cataracts. Capsulorhexis was completed in all cases; capsulorhexis was easy in 31 (94%) eyes and difficult in 2 (6%) eyes. In the two difficult cases, radial extension occurred in one eye, and it was retrieved using the Little technique; the other case with radial tear was completed successfully using a retinal micro scissor from the other edge of the capsulorhexis until reaching an oval, continuous capsulorhexis. Conclusions This modified capsulorhexis technique with compression on the posterior lip of the main incision and capsule milking allowed for a safe, continuous curvilinear capsulorhexis. Further comparative studies are necessary to confirm our preliminary results.
Collapse
Affiliation(s)
- Ehab M. Ghoneim
- Ophthalmology Department, Faculty of Medicine, Port Said University, Port Said, Egypt
| |
Collapse
|
11
|
Evaluation of femtosecond laser-assisted anterior capsulotomy in the presence of ophthalmic viscoelastic devices (OVDs). Sci Rep 2020; 10:21542. [PMID: 33298985 PMCID: PMC7726555 DOI: 10.1038/s41598-020-78361-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Accepted: 07/24/2020] [Indexed: 11/17/2022] Open
Abstract
The introduction of femtosecond laser-assisted cataract surgery is an alternative approach to conventional cataract surgery. Our study aimed to determine the effectiveness of femtosecond laser-assisted capsulotomy in the presence of different ophthalmic viscoelastic devices (OVDs) in the anterior chamber. Fresh porcine eyes (n = 96) underwent LDV Z8-assisted anterior capsulotomy, either in the presence of an OVD (Viscoat, Provisc, Healon, Healon GV or HPMC) or without, using 90% and 150% energies respectively. Following that, the capsule circularity, tag’s arc-length, tag-length, tag-area and rupture strength (mN) of the residual capsular bag were evaluated. We found that increasing energy from 90 to 150% across the OVD sub-groups improved the studied capsulotomy parameters. Amongst the 90% energy sub-groups, the circularity and tag-parameters were worse with Viscoat and Healon GV, which have higher refractive index and viscosity compared to the aqueous humour. Using 150% energy, Healon GV showed a significantly worse total arc-length (p = 0.01), total tag-length (p = 0.03) and total tag-area (p = 0.05) compared to the control group. We concluded that; an OVD with a refractive index similar to aqueous humour and lower viscosity, such as Healon or Provisc, as well as a higher energy setting, are recommended, to enhance the efficacy of laser capsulotomy.
Collapse
|