1
|
Rava RA, Mokin M, Snyder KV, Waqas M, Siddiqui AH, Davies JM, Levy EI, Ionita CN. Performance of angiographic parametric imaging in locating infarct core in large vessel occlusion acute ischemic stroke patients. J Med Imaging (Bellingham) 2020; 7:016001. [PMID: 32064301 PMCID: PMC7012174 DOI: 10.1117/1.jmi.7.1.016001] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Accepted: 01/27/2020] [Indexed: 12/26/2022] Open
Abstract
Purpose: Biomarkers related to hemodynamics can be quantified using angiographic parametric imaging (API), which is a quantitative imaging method that uses digital subtraction angiography (DSA). We aimed to assess the accuracy of API in locating infarct core within large vessel occlusion (LVO) acute ischemic stroke (AIS) patients. Approach: Data were retrospectively collected for 25 LVO AIS patients who achieved successful recanalization. DSA data from lateral and anteroposterior (AP) views were loaded into API software to generate hemodynamic parameter maps. Relative differences in hemispherical regions for each API parameter were calculated. Ground truth infarct core locations were obtained using 24-h follow-up fluid-attenuation inversion recovery (FLAIR) MRI imaging. FLAIR MRI infarct locations were registered with DSA images to determine infarct regions in API parameter maps. Relative differences across hemispheres for each API parameter were plotted against each other. A support vector machine was used to determine the optimal hyperplane for classifying regions as infarct or healthy tissue. Results: For the lateral and AP views, respectively, the most accurate classification of infarct regions came from plotting mean transit time (MTT) versus peak height (PH) [ accuracy = 0.8125 ± 0.0012 (95%)], the area under the receiver operator characteristic curve ( AUROC ) = 0.8946 ± 0.0000 (95%), and plotting MTT versus the area under the curve (AUC) [ accuracy = 0.7957 ± 0.0011 (95%), AUROC = 0.8759 ± 0.0000 (95%)]. Conclusions: API provides accurate assessment of locating ischemic core in AIS LVO patients and has the potential for clinical benefit by determining infarct core location and growth in real time for intraoperative decision making.
Collapse
Affiliation(s)
- Ryan A. Rava
- University at Buffalo, Department of Biomedical Engineering, Buffalo, New York, United States
- Canon Stroke and Vascular Research Center, Buffalo, New York, United States
| | - Maxim Mokin
- University of South Florida, Department of Neurosurgery, Tampa, Florida, United States
| | - Kenneth V. Snyder
- Canon Stroke and Vascular Research Center, Buffalo, New York, United States
- University at Buffalo, Department of Neurosurgery, Buffalo, New York, United States
| | - Muhammad Waqas
- Canon Stroke and Vascular Research Center, Buffalo, New York, United States
- University at Buffalo, Department of Neurosurgery, Buffalo, New York, United States
| | - Adnan H. Siddiqui
- Canon Stroke and Vascular Research Center, Buffalo, New York, United States
- University at Buffalo, Department of Neurosurgery, Buffalo, New York, United States
| | - Jason M. Davies
- Canon Stroke and Vascular Research Center, Buffalo, New York, United States
- University at Buffalo, Department of Neurosurgery, Buffalo, New York, United States
- University at Buffalo, Department of Bioinformatics, Buffalo, New York, United States
| | - Elad I. Levy
- Canon Stroke and Vascular Research Center, Buffalo, New York, United States
- University at Buffalo, Department of Neurosurgery, Buffalo, New York, United States
| | - Ciprian N. Ionita
- University at Buffalo, Department of Biomedical Engineering, Buffalo, New York, United States
- Canon Stroke and Vascular Research Center, Buffalo, New York, United States
| |
Collapse
|
2
|
Zaidat OO, Yoo AJ, Khatri P, Tomsick TA, von Kummer R, Saver JL, Marks MP, Prabhakaran S, Kallmes DF, Fitzsimmons BFM, Mocco J, Wardlaw JM, Barnwell SL, Jovin TG, Linfante I, Siddiqui AH, Alexander MJ, Hirsch JA, Wintermark M, Albers G, Woo HH, Heck DV, Lev M, Aviv R, Hacke W, Warach S, Broderick J, Derdeyn CP, Furlan A, Nogueira RG, Yavagal DR, Goyal M, Demchuk AM, Bendszus M, Liebeskind DS. Recommendations on angiographic revascularization grading standards for acute ischemic stroke: a consensus statement. Stroke 2013; 44:2650-63. [PMID: 23920012 PMCID: PMC4160883 DOI: 10.1161/strokeaha.113.001972] [Citation(s) in RCA: 1167] [Impact Index Per Article: 106.1] [Reference Citation Analysis] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Affiliation(s)
- Osama O Zaidat
- Department of Neurology, Medical College of Wisconsin, Milwaukee, WI, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|