• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4605583)   Today's Articles (21)   Subscriber (49373)
For: Yamazaki H, Hattori Y, Doi K. Delayed rupture of flexor tendons caused by protrusion of a screw head of a volar plate for distal radius fracture: a case report. ACTA ACUST UNITED AC 2010;13:27-9. [PMID: 18711781 DOI: 10.1142/s0218810408003785] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2007] [Accepted: 02/28/2008] [Indexed: 11/18/2022]
Number Cited by Other Article(s)
1
Flexor tendon rupture after volar plating of distal radius fracture: A systematic review of the literature. HAND SURGERY & REHABILITATION 2021;40:535-546. [PMID: 34033928 DOI: 10.1016/j.hansur.2021.05.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Revised: 05/06/2021] [Accepted: 05/11/2021] [Indexed: 11/22/2022]
2
Evaluation of flexor pollicis longus tendon attrition using color Doppler imaging after volar plate fixation for distal radius fracture. J Orthop Sci 2017;22:447-452. [PMID: 28325701 DOI: 10.1016/j.jos.2017.01.025] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/28/2016] [Revised: 11/16/2016] [Accepted: 01/03/2017] [Indexed: 11/21/2022]
3
Kwak DS, Lee JY, Im JH, Song HJ, Park D. Do volar locking plates fit the volar cortex of the distal radius? J Hand Surg Eur Vol 2017;42:266-270. [PMID: 27803378 DOI: 10.1177/1753193416676704] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
4
Shakir S, Naran S, Neral M, Wollstein R. Titanium versus Stainless-Steel Plating in the Surgical Treatment of Distal Radius Fractures: A Randomized Trial. J Hand Microsurg 2016;8:155-158. [PMID: 27999458 DOI: 10.1055/s-0036-1593731] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2016] [Accepted: 09/05/2016] [Indexed: 10/20/2022]  Open
5
Im JH, Lee JY. Pearls and Pitfalls of the Volar Locking Plating for Distal Radius Fractures. J Hand Surg Asian Pac Vol 2016;21:125-32. [PMID: 27454625 DOI: 10.1142/s242483551640004x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
6
Yamazaki H, Uchiyama S, Komatsu M, Hashimoto S, Kato H. Risk Assessment of Tendon Attrition Following Treatment of Distal Radius Fractures With Volar Locking Plates Using Audible Crepitus and Placement of the Plate: A Prospective Clinical Cohort Study. J Hand Surg Am 2015;40:1571-81. [PMID: 25944553 DOI: 10.1016/j.jhsa.2015.03.023] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/23/2014] [Revised: 03/20/2015] [Accepted: 03/24/2015] [Indexed: 02/02/2023]
7
Asadollahi S, Keith PPA. Flexor tendon injuries following plate fixation of distal radius fractures: a systematic review of the literature. J Orthop Traumatol 2013;14:227-34. [PMID: 23670492 PMCID: PMC3828490 DOI: 10.1007/s10195-013-0245-z] [Citation(s) in RCA: 72] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/23/2012] [Accepted: 04/18/2013] [Indexed: 10/28/2022]  Open
8
Macknin JB, Malone KJ. Zone 2 flexor digitorum profundus and superficialis rupture treated with single-stage tendon reconstruction using an Active Hunter Rod Implant. Orthopedics 2012;35:e758-61. [PMID: 22588423 DOI: 10.3928/01477447-20120426-36] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
9
McCann PA, Clarke D, Amirfeyz R, Bhatia R. The cadaveric anatomy of the distal radius: implications for the use of volar plates. Ann R Coll Surg Engl 2012;94:116-20. [PMID: 22391383 DOI: 10.1308/003588412x13171221501186] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]  Open
10
Rupture of Flexor Pollicis Longus Tendon: A Complication of Volar Locking Plating of the Distal Radius. Eur J Trauma Emerg Surg 2010;36:385-7. [PMID: 26816045 DOI: 10.1007/s00068-009-9021-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2009] [Accepted: 08/01/2009] [Indexed: 10/20/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA