Lifka S, Rehberger Y, Pastl K, Rofner-Moretti A, Reichkendler M, Baumgartner W. The Development and Biomechanical Analysis of an Allograft Interference Screw for Anterior Cruciate Ligament Reconstruction. Bioengineering (Basel) 2023; 10:1174. [PMID: 37892904 PMCID: PMC10604633 DOI: 10.3390/bioengineering10101174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Accepted: 10/06/2023] [Indexed: 10/29/2023] Open
Abstract
Graft fixation during cruciate ligament reconstruction using interference screws is a common and frequently used surgical technique. These interference screws are usually made of metal or bioabsorbable materials. This paper describes the development of an allograft interference screw from cortical human bone. During the design of the screw, particular attention was paid to the choice of the screw drive and the screw shape, as well as the thread shape. Based on these parameters, a prototype was designed and manufactured. Subsequently, the first biomechanical tests using a bovine model were performed. The test procedure comprised a torsion test to determine the ultimate failure torque of the screw and the insertion torque during graft fixation, as well as a pull-out test to asses the ultimate failure load of the graft fixation. The results of the biomechanical analysis showed that the mean value of the ultimate failure torque was 2633 Nmm, whereas the mean occurring insertion torque during graft fixation was only 1125 Nmm. The mean ultimate failure load of the graft fixation was approximately 235 N. The results of this work show a good overall performance of the allograft screw compared to conventional screws, and should serve as a starting point for further detailed investigations and studies.
Collapse
Affiliation(s)
- Sebastian Lifka
- Institute of Biomedical Mechatronics, Johannes Kepler University Linz, 4040 Linz, Austria
| | | | | | | | - Markus Reichkendler
- Department of Orthopedic and Trauma Surgery, District Hospital Schwaz, 6130 Schwaz, Austria
| | - Werner Baumgartner
- Institute of Biomedical Mechatronics, Johannes Kepler University Linz, 4040 Linz, Austria
| |
Collapse
|
2
|
Ab Rashid AM, Ramlee MH, Gan HS, Rafiq Abdul Kadir M. Effects of badminton insole design on stress distribution, displacement and bone rotation of ankle joint during single-leg landing: a finite element analysis. Sports Biomech 2022:1-22. [PMID: 35722740 DOI: 10.1080/14763141.2022.2086168] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Accepted: 05/31/2022] [Indexed: 10/18/2022]
Abstract
Previous research has reported that up to 92% of injuries amongst badminton players consist of lower limb, whereby 35% of foot fractures occurred at the metatarsal bone. In sports, insoles are widely used to increase athletes' performance and prevent many injuries. However, there is still a lack of badminton insole analysis and improvements. Therefore, this study aimed to biomechanically analyse three different insole designs. A validated and converged three-dimensional (3D) finite element model of ankle-foot complex was developed, which consisted of the skin, talus, calcaneus, navicular, three cuneiform, cuboid, five metatarsals and five phalanges. Three existing insoles from the market, (1) Yonex Active Pro Truactive, (2) Victor VT-XD 8 and (3) Li-Ning L6200LA, were scanned using a 3D scanner. For the analysis, single-leg landing was simulated. On the superior surface of the skin, 2.57 times of the bodyweight was axially applied, and the inferior surface of the outsole was fixed. The results showed that Insole 3 was the most optimum design to reduce peak stress on the metatarsals (3.807 MPa). In conclusion, the optimum design of Insole 3, based on the finite element analysis, could be a justification of athletes' choices to prevent injury and other complications.
Collapse
Affiliation(s)
- Amir Mustakim Ab Rashid
- Medical Devices and Technology Centre (MEDiTEC), Institute of Human Centered Engineering (iHumEn), Universiti Teknologi Malaysia, Johor Bahru, Malaysia
- Bioinspired Devices and Tissue Engineering (BIOINSPIRA) Research Group, School of Biomedical Engineering and Health Sciences, Faculty of Engineering, Universiti Teknologi Malaysia, Johor Bahru, Malaysia
| | - Muhammad Hanif Ramlee
- Medical Devices and Technology Centre (MEDiTEC), Institute of Human Centered Engineering (iHumEn), Universiti Teknologi Malaysia, Johor Bahru, Malaysia
- Bioinspired Devices and Tissue Engineering (BIOINSPIRA) Research Group, School of Biomedical Engineering and Health Sciences, Faculty of Engineering, Universiti Teknologi Malaysia, Johor Bahru, Malaysia
| | - Hong Seng Gan
- Department of Data Science, Universiti Malaysia Kelantan, 16100 UMK City Campus, Pengkalan Chepa, Kelantan, Malaysia
| | - Mohammed Rafiq Abdul Kadir
- Bioinspired Devices and Tissue Engineering (BIOINSPIRA) Research Group, School of Biomedical Engineering and Health Sciences, Faculty of Engineering, Universiti Teknologi Malaysia, Johor Bahru, Malaysia
- Sports Innovation and Technology Centre (SITC), Institute of Human Centered Engineering (iHumEn), Universiti Teknologi Malaysia, Johor Bahru, Malaysia
| |
Collapse
|
3
|
Wang S. Biomechanical Analysis of the Human Knee Joint. JOURNAL OF HEALTHCARE ENGINEERING 2022; 2022:9365362. [PMID: 35281538 PMCID: PMC8916872 DOI: 10.1155/2022/9365362] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Accepted: 01/31/2022] [Indexed: 11/24/2022]
Abstract
Exercise is an indispensable part of human daily life. The knee joint is inseparable from human movement. The knee is relatively fragile and easy to get injuries. Therefore, the biomechanical properties of knee joints were studied. The VICON T40S 3D motion acquisition and analysis system and the AMTI 3D force measurement platform were used to collect the lower limb kinematics and dynamics data of five male volunteers. Then the knee angle and moment of the human body are analyzed, the foot pressure was obtained by force plate, and the ground reaction force was obtained. The results show that: (1) in terms of knee flexion and extension torques, the peak stretching torques occurred in about 25% and 65% of the gait cycles. At the beginning of the gait, which is the flexion moment, the knee joint produces a moment of -24.65 Nmm, 25% of gait cycles reached the maximum peak value of 896.89 Nmm, 65% of gait cycles reached the second peak value of 315.81 Nmm; (2) The change of reaction force in a gait cycle is: when the ground starts to react, the ground reaction reaches 600 N. At normal times, the ground reaction force rapidly rises to the maximum value of 890 N; when the gait is in the middle of a single support phase, the ground reaction force is 462 N; when the ankle joint moves in plantar flexion, the ground reaction force increases to 830 N again; finally, when the toe is lifted off the ground, the ground reaction force quickly drops to zero; (3) in the course of a gait cycle, the spatial and temporal parameter curve distribution of the subjects was consistent, and the difference was not significant (P > 0.05).
Collapse
Affiliation(s)
- Sheng Wang
- Shanxi University, Taiyuan 030006, China
| |
Collapse
|
4
|
Zainal Abidin NA, Abdul Wahab AH, Abdul Rahim RA, Abdul Kadir MR, Ramlee MH. Biomechanical analysis of three different types of fixators for anterior cruciate ligament reconstruction via finite element method: a patient-specific study. Med Biol Eng Comput 2021; 59:1945-1960. [PMID: 34392448 DOI: 10.1007/s11517-021-02419-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 07/26/2021] [Indexed: 01/11/2023]
Abstract
Complication rates of anterior cruciate ligament reconstruction (ACL-R) were reported to be around 15% although it is a common arthroscopic procedure with good outcomes. Breakage and migration of fixators are still possible even months after surgery. A fixator with optimum stability can minimise those two complications. Factors that affect the stability of a fixator are its configuration, material, and design. Thus, this paper aims to analyse the biomechanical effects of different types of fixators (cross-pin, interference screw, and cortical button) towards the stability of the knee joint after ACL-R. In this study, finite element modelling and analyses of a knee joint attached with double semitendinosus graft and fixators were carried out. Mimics and 3-Matic softwares were used in the development of the knee joint models. Meanwhile, the graft and fixators were designed by using SolidWorks software. Once the meshes of all models were finished in 3-Matic, simulation of the configurations was done using MSC Marc Mentat software. A 100-N anterior tibial load was applied onto the tibia to simulate the anterior drawer test. Based on the findings, cross-pin was found to have optimum stability in terms of stress and strain at the femoral fixation site for better treatment of ACL-R.
Collapse
Affiliation(s)
- Nur Afikah Zainal Abidin
- Medical Devices & Technology Centre (MEDiTEC), Institute of Human Centered Engineering (iHumEn), Universiti Teknologi Malaysia, 81310, Johor Bahru, Johor, Malaysia.,Bioinspired Devices and Tissue Engineering (BIOINSPIRA) Group, School of Biomedical Engineering and Health Sciences, Faculty of Engineering, Universiti Teknologi Malaysia, 81310, Johor Bahru, Johor, Malaysia
| | - Abdul Hadi Abdul Wahab
- Centre for Multimodal Signal Processing, Faculty of Engineering and Technology, Tunku Abdul Rahman Universiti College, Jalan Genting Kelang, 53300, Setapak, Kuala Lumpur, Malaysia.,Department of Electrical and Electronics Engineering, Faculty of Engineering and Technology, Tunku Abdul Rahman Universiti College, Jalan Genting Kelang, 53300, Setapak, Kuala Lumpur, Malaysia
| | - Rabiatul Adibah Abdul Rahim
- Medical Devices & Technology Centre (MEDiTEC), Institute of Human Centered Engineering (iHumEn), Universiti Teknologi Malaysia, 81310, Johor Bahru, Johor, Malaysia
| | - Mohammed Rafiq Abdul Kadir
- Bioinspired Devices and Tissue Engineering (BIOINSPIRA) Group, School of Biomedical Engineering and Health Sciences, Faculty of Engineering, Universiti Teknologi Malaysia, 81310, Johor Bahru, Johor, Malaysia.,Sports Innovation and Technology Centre (SITC), Institute of Human Centered Engineering (iHumEn), Universiti Teknologi Malaysia, UTM, 81310, Johor Bahru, Johor, Malaysia
| | - Muhammad Hanif Ramlee
- Medical Devices & Technology Centre (MEDiTEC), Institute of Human Centered Engineering (iHumEn), Universiti Teknologi Malaysia, 81310, Johor Bahru, Johor, Malaysia. .,Bioinspired Devices and Tissue Engineering (BIOINSPIRA) Group, School of Biomedical Engineering and Health Sciences, Faculty of Engineering, Universiti Teknologi Malaysia, 81310, Johor Bahru, Johor, Malaysia.
| |
Collapse
|
5
|
Li G, Li J, Zuo S, Dong M. Influence of parameter deviation on the closeness of the tibial limb and external fixator based on a novel collision detection algorithm. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2021; 37:e3502. [PMID: 34114336 DOI: 10.1002/cnm.3502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 04/21/2021] [Accepted: 06/04/2021] [Indexed: 06/12/2023]
Abstract
The Ortho-SUV frame (OSF) is a hexapod external fixator widely applied in orthopedics deformity correction. The possibility of collision between OSF's struts and the soft tissue is an essential but overlooked issue. To avoid the issue, a novel collision detection algorithm is established based on a cone-cylinder model of the tibial limb-strut interaction for detecting the closeness of the tibial limb and external fixator. The algorithm is constructed using the vector analysis based on the model of the minimum distance between the truncated cone generatrix and the cylinder axis. The motion simulation is performed on the overall alignment through the Solidworks-motion module to verify the feasibility of the algorithm. Subsequently, the installation parameter deviations of the bone-fixator system are described to investigate the influence of orientation and position deviation on the closeness of the tibial limb and external fixator through the numerical method. The investigation results show that the orientation deviation γ (around the z-axis), the position deviation τ1 and τ2 (along the x and y-axes, respectively) have greater sensitivity to closeness and the influence of multiple deviations on the closeness has the property of superposition. The proposed algorithm can assist clinicians to strictly design and appraise frame configurations prior to their application to avoid the collision between the external fixator and the limbs during the correction. It has great application significance in the development of computer-aided correction software.
Collapse
Affiliation(s)
- Guotong Li
- Beijing Key Laboratory of Advanced Manufacturing Technology, Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing, PR China
| | - Jianfeng Li
- Beijing Key Laboratory of Advanced Manufacturing Technology, Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing, PR China
| | - Shiping Zuo
- Beijing Key Laboratory of Advanced Manufacturing Technology, Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing, PR China
| | - Mingjie Dong
- Beijing Key Laboratory of Advanced Manufacturing Technology, Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing, PR China
| |
Collapse
|