1
|
Liu S, Sureshkumar R. Deformation, Rupture, and Morphology Hysteresis of Copolymer Nanovesicles in Uniform Shear Flow. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2024. [PMID: 39739606 DOI: 10.1021/acs.langmuir.4c04200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2025]
Abstract
Copolymer nanovesicles are used extensively in chemical processes and biomedical applications in which they are subjected to dynamic flow environments. Flow-induced vesicle deformation, fragmentation, and reorganization modify the energetic (e.g., polymer-solvent interfacial area) and entropic (e.g., copolymer chain configuration) contributions to the solution free energy. Equilibration of a deformed morphology by flow cessation could reorganize the system into a self-assembled state, which is different from the parent structure through a local free energy minimization pathway. We perform nonequilibrium molecular dynamics simulations to investigate morphology evolution in uniform shear flow of a unilamellar nanovesicle formed by the self-assembly of amphiphilic triblock copolymers in an aqueous solution. Flow strength is characterized by the Weissenberg number Wi, defined as the ratio of the time scale of vesicle shape fluctuations to the inverse shear rate. For Wi < 10, a spherical vesicle deforms into a flow-aligned ellipsoidal bilayer executing tank-treading motion. For Wi > 10, pronounced variations in bilayer thickness and polymer extension manifest along the contour of the elongated vesicle, which breaks up into lamellar fragments. Below a critical strain, the deformed vesicle upon flow cessation returns to its initial spherical morphology. However, for larger strains, structure reorganization after flow stoppage results in the formation of a Novel Equilibrated Shear-Induced Structure (NoESIS) in which two vesicles are connected by a dynamic molecular bridge that can accommodate additional layers of copolymers, leading to a reduction in the polymer-solvent interface area. Mechanisms of morphology hysteresis are explored via an analysis of the thermodynamic markers.
Collapse
Affiliation(s)
- Senyuan Liu
- Department of Biomedical and Chemical Engineering and the Bioinspired Institute, Syracuse University, Syracuse, New York 13244, United States
| | - Radhakrishna Sureshkumar
- Department of Biomedical and Chemical Engineering and the Bioinspired Institute, Syracuse University, Syracuse, New York 13244, United States
- Department of Physics, Syracuse University, Syracuse, New York 13244, United States
| |
Collapse
|
2
|
Lee S, Bashir KMI, Jung DH, Basu SK, Seo G, Cho MG, Wierschem A. Measuring the linear viscoelastic regime of MCF-7 cells with a monolayer rheometer in the presence of microtubule-active anti-cancer drugs at high concentrations. Interface Focus 2022; 12:20220036. [PMID: 36330318 PMCID: PMC9560786 DOI: 10.1098/rsfs.2022.0036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Accepted: 09/06/2022] [Indexed: 10/16/2023] Open
Abstract
The rheological properties of cells have vital functional implications. Depending, for instance, on the life cycle, cells show large cell-to-cell variations making it cumbersome to quantify average viscoelastic properties of cells by single-cell techniques. Microfluidic devices, typically working in the nonlinear viscoelastic range, allow fast analysis of single-cell deformation. Averaging over a large number of cells can also be achieved by studying them in a monolayer between rheometer discs. This technique allows applying well-established rheological standard procedures to cell rheology. It offers further advantages like studying cells in the linear viscoelastic range while quantifying cell vitality. Here, we study the applicability of the technique to rather adverse conditions, like for microtubule-active anti-cancer drugs and for a cell line with large size variation. We found a strong impact of the gap width and of normal forces on the moduli and obtained high vitality levels during the rheological study. To enable studying the impact of microtubule-active drugs on vital cells at concentrations several orders of magnitude beyond the half maximal effective concentration for cytotoxicity, we arrested the cell cycle with hydroxyurea. Irrespective of the high concentrations, we observed no clear impact of the microtubule-active drugs.
Collapse
Affiliation(s)
- Suhyang Lee
- German Engineering Research and Development Center, LSTME-Busan Branch, Gangseo-Gu, Busan 46742, Republic of Korea
- Institute of Fluid Mechanics, Friedrich-Alexander-Universität Erlangen-Nürnberg, Cauerstr. 4, Erlangen 91058, Germany
| | | | - Dong Hee Jung
- German Engineering Research and Development Center, LSTME-Busan Branch, Gangseo-Gu, Busan 46742, Republic of Korea
- Division of Energy and Bioengineering, Dongseo University, Sasang-gu, Busan 47011, Republic of Korea
| | - Santanu Kumar Basu
- Institute of Fluid Mechanics, Friedrich-Alexander-Universität Erlangen-Nürnberg, Cauerstr. 4, Erlangen 91058, Germany
| | - Gayeon Seo
- Division of Energy and Bioengineering, Dongseo University, Sasang-gu, Busan 47011, Republic of Korea
| | - Man-Gi Cho
- German Engineering Research and Development Center, LSTME-Busan Branch, Gangseo-Gu, Busan 46742, Republic of Korea
- Division of Energy and Bioengineering, Dongseo University, Sasang-gu, Busan 47011, Republic of Korea
| | - Andreas Wierschem
- German Engineering Research and Development Center, LSTME-Busan Branch, Gangseo-Gu, Busan 46742, Republic of Korea
- Institute of Fluid Mechanics, Friedrich-Alexander-Universität Erlangen-Nürnberg, Cauerstr. 4, Erlangen 91058, Germany
| |
Collapse
|
3
|
Major R, Wilczek G, Więcek J, Gawlikowski M, Plutecka H, Kasperkiewicz K, Kot M, Pomorska M, Ostrowski R, Kopernik M. Hemocompatibile Thin Films Assessed under Blood Flow Shear Forces. Molecules 2022; 27:molecules27175696. [PMID: 36080463 PMCID: PMC9458224 DOI: 10.3390/molecules27175696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Revised: 08/23/2022] [Accepted: 09/01/2022] [Indexed: 11/16/2022] Open
Abstract
The aim of this study was to minimize the risk of life-threatening thromboembolism in the ventricle through the use of a new biomimetic heart valve based on metal-polymer composites. Finite volume element simulations of blood adhesion to the material were carried out, encompassing radial flow and the cone and plane test together with determination of the effect of boundary conditions. Both tilt-disc and bicuspid valves do not have optimized blood flow due to their design based on rigid valve materials (leaflet made of pyrolytic carbon). The main objective was the development of materials with specific properties dedicated to contact with blood. Materials were evaluated by dynamic tests using blood, concentrates, and whole human blood. Hemostability tests under hydrodynamic conditions were related to the mechanical properties of thin-film materials obtained from tribological tests. The quality of the coatings was high enough to avoid damage to the coating even as they were exposed up to maximum loading. Analysis towards blood concentrates of the hydrogenated carbon sample and the nitrogen-doped hydrogenated carbon sample revealed that the interaction of the coating with erythrocytes was the strongest. Hemocompatibility evaluation under hydrodynamic conditions confirmed very good properties of the developed coatings.
Collapse
Affiliation(s)
- Roman Major
- Institute of Metallurgy and Materials Science, Polish Academy of Sciences, 25 Reymonta St., 30-059 Cracow, Poland
| | - Grażyna Wilczek
- Institute of Biology, Biotechnology and Environmental Protection, University of Silesia, Bankowa St. 9, 40-007 Katowice, Poland
| | - Justyna Więcek
- Institute of Metallurgy and Materials Science, Polish Academy of Sciences, 25 Reymonta St., 30-059 Cracow, Poland
| | - Maciej Gawlikowski
- Faculty of Biomedical Engineering, Department of Biosensors and Processing of Biomedical Signals, Silesian University of Technology, Roosevelt St. 40, 41-800 Zabrze, Poland
| | - Hanna Plutecka
- Division of Molecular Biology and Clinical Genetics, Faculty of Medicine, Jagiellonian University Medical College, Skawinska St. 8, 31-066 Cracow, Poland
| | - Katarzyna Kasperkiewicz
- Institute of Biology, Biotechnology and Environmental Protection, Faculty of Natural Sciences, University of Silesia in Katowice, Jagiellońska St., 2840-032 Katowice, Poland
| | - Marcin Kot
- Faculty of Mechanical Engineering and Robotics, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow, Poland
| | - Małgorzata Pomorska
- Institute of Metallurgy and Materials Science, Polish Academy of Sciences, 25 Reymonta St., 30-059 Cracow, Poland
| | - Roman Ostrowski
- Institute of Optoelectronics, Military University of Technology, Gen. S. Kaliskiego St. 2, 00-908 Warsaw, Poland
| | - Magdalena Kopernik
- Faculty of Metals Engineering and Industrial Computer Science, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow, Poland
- Correspondence: ; Tel.: +48-12-617-51-26
| |
Collapse
|
4
|
Bashir KMI, Lee S, Jung DH, Basu SK, Cho MG, Wierschem A. Narrow-Gap Rheometry: A Novel Method for Measuring Cell Mechanics. Cells 2022; 11:2010. [PMID: 35805094 PMCID: PMC9265971 DOI: 10.3390/cells11132010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Revised: 06/21/2022] [Accepted: 06/21/2022] [Indexed: 12/18/2022] Open
Abstract
The viscoelastic properties of a cell cytoskeleton contain abundant information about the state of a cell. Cells show a response to a specific environment or an administered drug through changes in their viscoelastic properties. Studies of single cells have shown that chemical agents that interact with the cytoskeleton can alter mechanical cell properties and suppress mitosis. This envisions using rheological measurements as a non-specific tool for drug development, the pharmacological screening of new drug agents, and to optimize dosage. Although there exists a number of sophisticated methods for studying mechanical properties of single cells, studying concentration dependencies is difficult and cumbersome with these methods: large cell-to-cell variations demand high repetition rates to obtain statistically significant data. Furthermore, method-induced changes in the cell mechanics cannot be excluded when working in a nonlinear viscoelastic range. To address these issues, we not only compared narrow-gap rheometry with commonly used single cell techniques, such as atomic force microscopy and microfluidic-based approaches, but we also compared existing cell monolayer studies used to estimate cell mechanical properties. This review provides insight for whether and how narrow-gap rheometer could be used as an efficient drug screening tool, which could further improve our current understanding of the mechanical issues present in the treatment of human diseases.
Collapse
Affiliation(s)
- Khawaja Muhammad Imran Bashir
- German Engineering Research and Development Center, LSTME-Busan Branch, Busan 46742, Korea; (K.M.I.B.); (S.L.); (D.H.J.); (M.-G.C.)
| | - Suhyang Lee
- German Engineering Research and Development Center, LSTME-Busan Branch, Busan 46742, Korea; (K.M.I.B.); (S.L.); (D.H.J.); (M.-G.C.)
- Institute of Fluid Mechanics, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), 91058 Erlangen, Germany;
| | - Dong Hee Jung
- German Engineering Research and Development Center, LSTME-Busan Branch, Busan 46742, Korea; (K.M.I.B.); (S.L.); (D.H.J.); (M.-G.C.)
- Division of Energy and Bioengineering, Dongseo University, Busan 47011, Korea
| | - Santanu Kumar Basu
- Institute of Fluid Mechanics, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), 91058 Erlangen, Germany;
| | - Man-Gi Cho
- German Engineering Research and Development Center, LSTME-Busan Branch, Busan 46742, Korea; (K.M.I.B.); (S.L.); (D.H.J.); (M.-G.C.)
- Division of Energy and Bioengineering, Dongseo University, Busan 47011, Korea
| | - Andreas Wierschem
- German Engineering Research and Development Center, LSTME-Busan Branch, Busan 46742, Korea; (K.M.I.B.); (S.L.); (D.H.J.); (M.-G.C.)
- Institute of Fluid Mechanics, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), 91058 Erlangen, Germany;
| |
Collapse
|
5
|
Qiu S, Shen C, Jian X, Lu Y, Tong Z, Wu Z, Mao H, Zhao J. Single-cell level point mutation analysis of circulating tumor cells through droplet microfluidics. CHINESE CHEM LETT 2022. [DOI: 10.1016/j.cclet.2021.08.128] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
6
|
Abstract
Scanning ion conductance microscopy (SICM) has emerged as a versatile tool for studies of interfaces in biology and materials science with notable utility in biophysical and electrochemical measurements. The heart of the SICM is a nanometer-scale electrolyte filled glass pipette that serves as a scanning probe. In the initial conception, manipulations of ion currents through the tip of the pipette and appropriate positioning hardware provided a route to recording micro- and nanoscopic mapping of the topography of surfaces. Subsequent advances in instrumentation, probe design, and methods significantly increased opportunities for SICM beyond recording topography. Hybridization of SICM with coincident characterization techniques such as optical microscopy and faradaic electrodes have brought SICM to the forefront as a tool for nanoscale chemical measurement for a wide range of applications. Modern approaches to SICM realize an important tool in analytical, bioanalytical, biophysical, and materials measurements, where significant opportunities remain for further exploration. In this review, we chronicle the development of SICM from the perspective of both the development of instrumentation and methods and the breadth of measurements performed.
Collapse
Affiliation(s)
- Cheng Zhu
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Kaixiang Huang
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Natasha P Siepser
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Lane A Baker
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| |
Collapse
|
7
|
Pazdzior R, Kubicek S. PlateFlo - A software-controllable plate-scale perfusion system for culture of adherent cells. HARDWAREX 2021; 10:e00222. [PMID: 35607664 PMCID: PMC9123465 DOI: 10.1016/j.ohx.2021.e00222] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 07/23/2021] [Accepted: 08/05/2021] [Indexed: 06/15/2023]
Abstract
Here we present a versatile system for milliliter-scale perfusion culture of adherent cells that can be built using basic tools, based on a readily available one-well culture plate (84 cm2 culture area). Media composition and flow paths can be programmatically controlled via USB serial interface using the FETbox hardware controller and associated PlateFlo Python package. The FETbox can control up to five high current 12 V devices such as common pinch valves, solenoids, and DC motor peristaltic pumps. It was designed to be easily customized with built-in accommodation for additional electronic components (e.g. analog sensors and input), use of the ubiquitous Arduino Nano platform, and easily expanded serial communication protocol. Multiple FETboxes can be used in parallel for additional devices. Applications of the PlateFlo system include perfusion culture of laboratory experiments requiring large cell numbers including genome-scale genetic screens and proteomics, as well as novel perfusion schemes including dynamic media conditions and sequential cell culture.
Collapse
Key Words
- Adherent
- Automation
- BOM, bill of materials
- CFD, computational fluid dynamics
- Cell culture
- DMEM, Dulbecco’s modified Eagle’s medium
- EUR, Euro
- FDM, fused deposition modelling
- MCU, microcontroller unit
- MOSFET, metal oxide semiconductor field effect transistor
- Microplate
- Millifluidic
- PBS, phosphate-buffered saline
- PCB, printed circuit board
- PWM, pulse width modulation
- Perfusion
- hIPSC, human induced pluripotent stem cell
Collapse
|
8
|
Microfabricated Devices for Confocal Microscopy on Biological Samples. Methods Mol Biol 2021. [PMID: 34028712 DOI: 10.1007/978-1-0716-1402-0_4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
Abstract
Microfabricated devices have found applications in a range of biomedical research problems in recent years, with thousands of research papers published and multiple commercial devices now available. This chapter is intended to provide an overview of the available options for devices compatible with confocal microscopy, including an overview of fabrication techniques and some examples of device use. Although there are times when off-the-shelf devices are well suited for the problem at hand, in some cases customized devices are necessary or more convenient. Protocols for researchers who wish to make their own devices are outlined below; although fabricating templates for devices requires some specialized equipment, making PDMS or hydrogel devices from templates can be done in a standard laboratory setting.
Collapse
|
9
|
Pereiro I, Aubert J, Kaigala GV. Micro-scale technologies propel biology and medicine. BIOMICROFLUIDICS 2021; 15:021302. [PMID: 33948133 PMCID: PMC8081554 DOI: 10.1063/5.0047196] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Accepted: 04/05/2021] [Indexed: 05/05/2023]
Abstract
Historically, technology has been central to new discoveries in biology and progress in medicine. Among various technologies, microtechnologies, in particular, have had a prominent role in the revolution experienced by the life sciences in the last few decades, which will surely continue in the years to come. In this Perspective, we illustrate how microtechnologies, with a focus on microfluidics, have evolved in trends/waves to tackle the boundary of knowledge in the life sciences. We provide illustrative examples of technology-enabled biological breakthroughs and their current and future use in clinics. Finally, we take a closer look at the translational process to understand why the incorporation of new micro-scale technologies in medicine has been comparatively slow so far.
Collapse
|
10
|
Zhou K, Dey M, Ayan B, Zhang Z, Ozbolat V, Kim MH, Khristov V, Ozbolat IT. Fabrication of PDMS microfluidic devices using nanoclay-reinforced Pluronic F-127 as a sacrificial ink. Biomed Mater 2021; 16:045005. [PMID: 33571984 DOI: 10.1088/1748-605x/abe55e] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Three-dimensional (3D) printing technology is increasingly being employed in biochemical as well as clinical applications and more importantly in fabrication of microfluidic devices. However, the microfluidic community mainly relies on photolithography for fabrication of a defined mask, which is both tedious and expensive requiring clean room settings as well as limited to the generation of two-dimensional (2D) features. In this work, we 3D printed nanoclay-reinforced Pluronic ink as a sacrificial material, which exhibited shear thinning behavior and superior printability allowing the fabrication of unsupported or overhanging templates of channels with uniform diameter and circular cross-sections. To highlight the potential and effectiveness of the presented approach, we fabricated a human blood vessel-on-a-chip model with curved as well as straight channels. These channels were then lined with Human Umbilical Vein Endothelial cells (HUVECs) and subjected to a dynamic culture for 10 days to explore the effect of shear stress on HUVEC morphology based on the location of HUVECs in the devices. Overall, we presented a highly affordable, useful, and practical approach in fabrication of closed microfluidic channels in PDMS based devices, which holds great potential for numerous applications, such as but not limited to tissue/organ-on-chip, microfluidics, point-of-care devices and drug screening platforms.
Collapse
Affiliation(s)
- Kui Zhou
- Nanchang University, School of Mechanic & Electronic Engineering, Nanchang, 330031, CHINA
| | - Madhuri Dey
- Penn State, W313 MSC, University Park, Pennsylvania, 16802, UNITED STATES
| | - Bugra Ayan
- Penn State, W313 MSC, University Park, Pennsylvania, 16802, UNITED STATES
| | - Zhifeng Zhang
- Penn State, W313 MSC, University Park, Pennsylvania, 16802, UNITED STATES
| | - Veli Ozbolat
- Cukurova Universitesi, Ceyhan Engineering Faculty, Adana, 01950, TURKEY
| | - Myoung Hwan Kim
- Penn State, W313, University Park, Pennsylvania, 16802, UNITED STATES
| | - Vladimir Khristov
- Penn State, Neurosurgery, Herhsey, Pennsylvania, 17033, UNITED STATES
| | - Ibrahim T Ozbolat
- Penn State, W313 MSC, University Park, Pennsylvania, 16802, UNITED STATES
| |
Collapse
|
11
|
Mirzaaghaian A, Ramiar A, Ranjbar AA, Warkiani ME. Application of level-set method in simulation of normal and cancer cells deformability within a microfluidic device. J Biomech 2020; 112:110066. [DOI: 10.1016/j.jbiomech.2020.110066] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2020] [Revised: 09/06/2020] [Accepted: 09/17/2020] [Indexed: 12/11/2022]
|
12
|
Trembecka-Wójciga K, Kopernik M, Surmiak M, Major R, Gawlikowski M, Bruckert F, Kot M, Lackner JM. Effect of the mechanical properties of carbon-based coatings on the mechanics of cell-material interactions. Colloids Surf B Biointerfaces 2020; 197:111359. [PMID: 33032179 DOI: 10.1016/j.colsurfb.2020.111359] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Revised: 08/31/2020] [Accepted: 09/02/2020] [Indexed: 12/28/2022]
Abstract
The paper presents an influence of the surface mechanical properties of thin-film materials on blood cell adhesion under shear stress conditions. Physical vapour deposited (PVD) coatings i.e. hydrogenated amorphous carbon (a-C:H) doped with nitrogen or silicon have been investigated. The mechanical properties of materials, namely their microhardness and Young's modulus were measured using indentation test with Rockwell indenter. The adhesion efficiency of blood cells in dynamic conditions were analysed using a radial flow chamber. Red blood cells (RBC) were used as representative cells to analyse cell-material interactions. The biomaterial examinations were performed under physiological flow conditions at the single-cell level. The 3D FVM (finite volume method) model of multi-phase radial flow test was developed to reproduce the physical test and to predict distributions of shear stresses and velocity during blood washout with PBS. Cell-material interactions were found to be strongly associated with the mechanical properties of the thin-film material. The decrease in the hardness of the coatings translated into a weaker cell - material interactions.
Collapse
Affiliation(s)
- K Trembecka-Wójciga
- Institute of Metallurgy and Materials Science, Polish Academy of Sciences, Reymonta St. 25, Cracow, Poland
| | - M Kopernik
- AGH University of Science and Technology, Mickiewicza Str. 30, Cracow, Poland.
| | - M Surmiak
- Department of Internal Medicine, Jagiellonian University Medical College, Skawinska Str. 8, Cracow, Poland
| | - R Major
- Institute of Metallurgy and Materials Science, Polish Academy of Sciences, Reymonta St. 25, Cracow, Poland
| | - M Gawlikowski
- Silesian University of Technology, Faculty of Biomedical Engineering, Department of Biosensors and Processing of Biomedical Signals, Roosevelt Str. 40, Zabrze, Poland
| | - F Bruckert
- Laboratoire des Matériaux et du Génie Physique - UMR 5628, 3 parvis Louis Néel, Grenoble Cedex 1, France
| | - M Kot
- Faculty of Mechanical Engineering and Robotics, AGH University of Science and Technology, Mickiewicza Str. 30, Cracow, Poland
| | - J M Lackner
- Joanneum Research Forschungsges mbH, Institute of Surface Technologies and Photonics, Functional Surfaces, Leobner Strasse 94, A-8712, Niklasdorf, Austria
| |
Collapse
|
13
|
Elias M, Dutoya A, Laborde A, Lecestre A, Montis C, Caselli L, Berti D, Lonetti B, Roux C, Joseph P. Microfluidic characterization of biomimetic membrane mechanics with an on-chip micropipette. MICRO AND NANO ENGINEERING 2020. [DOI: 10.1016/j.mne.2020.100064] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
14
|
Laumann M, Zimmermann W. Focusing and splitting streams of soft particles in microflows via viscosity gradients. THE EUROPEAN PHYSICAL JOURNAL. E, SOFT MATTER 2019; 42:108. [PMID: 31444586 DOI: 10.1140/epje/i2019-11872-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Accepted: 07/18/2019] [Indexed: 06/10/2023]
Abstract
Microflows are intensively used for investigating and controlling the dynamics of particles, including soft particles such as biological cells and capsules. A classic result is the tank-treading motion of elliptically deformed soft particles in linear shear flows, which do not migrate across straight streamlines in the bulk. However, soft particles migrate across straight streamlines in Poiseuille flows. In this work we describe a new mechanism of cross-streamline migration by using soft capsules with a spherical equilibrium shape. If the viscosity varies perpendicular to the streamlines then the soft particles migrate across streamlines towards regions of a lower viscosity, even in linear shear flows. An interplay with the repulsive particle-boundary interaction causes then focusing of particles in linear shear flows with the attractor streamline closer to the wall in the low viscosity region. Viscosity variations perpendicular to the streamlines in Poiseuille flows leads either to a shift of the particle attractor or even to a splitting of particle attractors, which may give rise to interesting applications for particle separation. The location of attracting streamlines depend on the particle properties, like their size and elasticity. The cross-stream migration induced by viscosity variations is explained by analytical considerations, Stokesian dynamics simulations with a generalized Oseen tensor and lattice-Boltzmann simulations.
Collapse
Affiliation(s)
- Matthias Laumann
- Theoretische Physik I, Universität Bayreuth, 95440, Bayreuth, Germany
| | - Walter Zimmermann
- Theoretische Physik I, Universität Bayreuth, 95440, Bayreuth, Germany.
| |
Collapse
|
15
|
Bidhendi AJ, Geitmann A. Methods to quantify primary plant cell wall mechanics. JOURNAL OF EXPERIMENTAL BOTANY 2019; 70:3615-3648. [PMID: 31301141 DOI: 10.1093/jxb/erz281] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2018] [Accepted: 06/26/2019] [Indexed: 05/23/2023]
Abstract
The primary plant cell wall is a dynamically regulated composite material of multiple biopolymers that forms a scaffold enclosing the plant cells. The mechanochemical make-up of this polymer network regulates growth, morphogenesis, and stability at the cell and tissue scales. To understand the dynamics of cell wall mechanics, and how it correlates with cellular activities, several experimental frameworks have been deployed in recent years to quantify the mechanical properties of plant cells and tissues. Here we critically review the application of biomechanical tool sets pertinent to plant cell mechanics and outline some of their findings, relevance, and limitations. We also discuss methods that are less explored but hold great potential for the field, including multiscale in silico mechanical modeling that will enable a unified understanding of the mechanical behavior across the scales. Our overview reveals significant differences between the results of different mechanical testing techniques on plant material. Specifically, indentation techniques seem to consistently report lower values compared with tensile tests. Such differences may in part be due to inherent differences among the technical approaches and consequently the wall properties that they measure, and partly due to differences between experimental conditions.
Collapse
Affiliation(s)
- Amir J Bidhendi
- Department of Plant Science, McGill University, Macdonald Campus, Lakeshore, Ste-Anne-de-Bellevue, Québec, Canada
- Institut de recherche en biologie végétale, Département de sciences biologiques, Université de Montréal, Montreal, Quebec, Canada
| | - Anja Geitmann
- Department of Plant Science, McGill University, Macdonald Campus, Lakeshore, Ste-Anne-de-Bellevue, Québec, Canada
| |
Collapse
|
16
|
Spatarelu CP, Zhang H, Trung Nguyen D, Han X, Liu R, Guo Q, Notbohm J, Fan J, Liu L, Chen Z. Biomechanics of Collective Cell Migration in Cancer Progression: Experimental and Computational Methods. ACS Biomater Sci Eng 2019; 5:3766-3787. [PMID: 32953985 PMCID: PMC7500334 DOI: 10.1021/acsbiomaterials.8b01428] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Cell migration is essential for regulating many biological processes in physiological or pathological conditions, including embryonic development and cancer invasion. In vitro and in silico studies suggest that collective cell migration is associated with some biomechanical particularities such as restructuring of extracellular matrix (ECM), stress and force distribution profiles, and reorganization of the cytoskeleton. Therefore, the phenomenon could be understood by an in-depth study of cells' behavior determinants, including but not limited to mechanical cues from the environment and from fellow "travelers". This review article aims to cover the recent development of experimental and computational methods for studying the biomechanics of collective cell migration during cancer progression and invasion. We also summarized the tested hypotheses regarding the mechanism underlying collective cell migration enabled by these methods. Together, the paper enables a broad overview on the methods and tools currently available to unravel the biophysical mechanisms pertinent to cell collective migration as well as providing perspectives on future development toward eventually deciphering the key mechanisms behind the most lethal feature of cancer.
Collapse
Affiliation(s)
| | - Hao Zhang
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire 03755, United States
| | - Dung Trung Nguyen
- Department of Engineering and Computer Science, Seattle Pacific University, Seattle, Washington 98119,
United States
| | - Xinyue Han
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire 03755, United States
| | - Ruchuan Liu
- College of Physics, Chongqing University, Chongqing 400032, China
| | - Qiaohang Guo
- School of Materials Science and Engineering, Fujian University of Technology, Fuzhou 350014,
China
| | - Jacob Notbohm
- Department of Engineering Physics, University of Wisconsin—Madison, Madison, Wisconsin 53706,
United States
| | - Jing Fan
- Department of Mechanical Engineering, City College of City University of New York, New York 10031, United
States
| | - Liyu Liu
- College of Physics, Chongqing University, Chongqing 400032, China
| | - Zi Chen
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire 03755, United States
| |
Collapse
|
17
|
Harrison DL, Fang Y, Huang J. T-Cell Mechanobiology: Force Sensation, Potentiation, and Translation. FRONTIERS IN PHYSICS 2019; 7:45. [PMID: 32601597 PMCID: PMC7323161 DOI: 10.3389/fphy.2019.00045] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
A T cell is a sensitive self-referential mechanical sensor. Mechanical forces influence the recognition, activation, differentiation, and function throughout the lifetime of a T cell. T cells constantly perceive and respond to physical stimuli through their surface receptors, cytoskeleton, and subcellular structures. Surface receptors receive physical cues in the form of forces generated through receptor-ligand binding events, which are dynamically regulated by contact tension, shear stress, and substrate rigidity. The resulting mechanotransduction not only influences T-cell recognition and signaling but also possibly modulates cell metabolism and gene expression. Moreover, forces also dynamically regulate the deformation, organization, and translocation of cytoskeleton and subcellular structures, leading to changes in T-cell mobility, migration, and infiltration. However, the roles and mechanisms of how mechanical forces modulate T-cell recognition, signaling, metabolism, and gene expression, are largely unknown and underappreciated. Here, we review recent technological and scientific advances in T-cell mechanobiology, discuss possible roles and mechanisms of T-cell mechanotransduction, and propose new research directions of this emerging field in health and disease.
Collapse
Affiliation(s)
- Devin L. Harrison
- The Graduate Program in Biophysical Sciences, The University of Chicago, Chicago, IL, United States
| | - Yun Fang
- The Graduate Program in Biophysical Sciences, The University of Chicago, Chicago, IL, United States
- Section of Pulmonary and Critical Care, Department of Medicine, The University of Chicago, Chicago, IL, United States
| | - Jun Huang
- The Graduate Program in Biophysical Sciences, The University of Chicago, Chicago, IL, United States
- Institute for Molecular Engineering, The University of Chicago, Chicago, IL, United States
| |
Collapse
|
18
|
Laumann M, Schmidt W, Farutin A, Kienle D, Förster S, Misbah C, Zimmermann W. Emerging Attractor in Wavy Poiseuille Flows Triggers Sorting of Biological Cells. PHYSICAL REVIEW LETTERS 2019; 122:128002. [PMID: 30978078 DOI: 10.1103/physrevlett.122.128002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/28/2018] [Indexed: 06/09/2023]
Abstract
Microflows constitute an important instrument to control particle dynamics. A prominent example is the sorting of biological cells, which relies on the ability of deformable cells to move transversely to flow lines. A classic result is that soft microparticles migrate in flows through straight microchannels to an attractor at their center. Here, we show that flows through wavy channels fundamentally change the overall picture. They lead to the emergence of a second, coexisting attractor for soft particles. Its emergence and off-center location depends on the boundary modulation and the particle properties. The related cross-stream migration of soft particles is explained by analytical considerations, Stokesian dynamics simulations in unbounded flows, and Lattice-Boltzmann simulations in bounded flows. The novel off-center attractor can be used, for instance, in diagnostics, for separating cells of different size and elasticity, which is often an indicator of their health status.
Collapse
Affiliation(s)
- Matthias Laumann
- Theoretische Physik I, Universität Bayreuth, 95440 Bayreuth, Germany
- Universite Grenoble Alpes/CNRS UMR 5588, LIPhy, 38041 Grenoble, France
| | - Winfried Schmidt
- Theoretische Physik I, Universität Bayreuth, 95440 Bayreuth, Germany
| | - Alexander Farutin
- Universite Grenoble Alpes/CNRS UMR 5588, LIPhy, 38041 Grenoble, France
| | - Diego Kienle
- Theoretische Physik I, Universität Bayreuth, 95440 Bayreuth, Germany
| | - Stephan Förster
- JNCS-1/ICS-1, Forschungszentrum Jülich, 52428 Jülich, Germany
| | - Chaouqi Misbah
- Theoretische Physik I, Universität Bayreuth, 95440 Bayreuth, Germany
- Universite Grenoble Alpes/CNRS UMR 5588, LIPhy, 38041 Grenoble, France
| | - Walter Zimmermann
- Theoretische Physik I, Universität Bayreuth, 95440 Bayreuth, Germany
| |
Collapse
|
19
|
Luo ZY, Bai BF. Off-center motion of a trapped elastic capsule in a microfluidic channel with a narrow constriction. SOFT MATTER 2017; 13:8281-8292. [PMID: 29071316 DOI: 10.1039/c7sm01425b] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Owing to their significance in capsule-related engineering and biomedical applications, a number of studies have considered the dynamics of elastic capsules flowing in constricted microchannels. However, these studies have focused on capsules moving along the channel centerline. In the present study, we numerically investigate the transient motion of an elastic capsule in a microfluidic channel with a rectangular constriction, which is initially trapped at the constriction inlet while off the channel centerline (i.e., on the channel bottom-wall). Under the push of the surrounding flow, the capsule can squeeze into the constriction, but only if the capsule deformability or the constriction size is sufficiently large. We find that the critical capillary number leading to the penetration of the capsule into the constriction is larger for off-centerline capsules compared to centered capsules. The centered capsule is stationary at the steady state when it remains stuck at the constriction; in contrast, the off-centerline capsule is not stationary but exhibits a tank-treading motion, i.e., its overall shape maintains a nonspherical shape with a protrusion into the constriction while its membrane exhibits a continuous rotation. Further, we examine the dependence of the capsule motion type, capsule deformation degree and membrane tension distribution on the capillary number (measuring the effects of flow strength and membrane mechanics) and constriction geometries (including the constriction height and width). Finally, we discuss the mechanism governing the capsule motion by analyzing the hydrodynamic forces acting on the capsule. The shear force acting on the capsule top owing to the fluid flow in the gap between the capsule top and the channel top-wall is the main source inducing the membrane tank-treading rotation.
Collapse
Affiliation(s)
- Zheng Yuan Luo
- State Key Laboratory of Multiphase Flow in Power Engineering, Xi'an Jiaotong University, Xi'an 710049, P. R. China.
| | | |
Collapse
|
20
|
Perrier DL, Rems L, Boukany PE. Lipid vesicles in pulsed electric fields: Fundamental principles of the membrane response and its biomedical applications. Adv Colloid Interface Sci 2017; 249:248-271. [PMID: 28499600 DOI: 10.1016/j.cis.2017.04.016] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2017] [Revised: 04/24/2017] [Accepted: 04/25/2017] [Indexed: 01/04/2023]
Abstract
The present review focuses on the effects of pulsed electric fields on lipid vesicles ranging from giant unilamellar vesicles (GUVs) to small unilamellar vesicles (SUVs), from both fundamental and applicative perspectives. Lipid vesicles are the most popular model membrane systems for studying biophysical and biological processes in living cells. Furthermore, as vesicles are made from biocompatible and biodegradable materials, they provide a strategy to create safe and functionalized drug delivery systems in health-care applications. Exposure of lipid vesicles to pulsed electric fields is a common physical method to transiently increase the permeability of the lipid membrane. This method, termed electroporation, has shown many advantages for delivering exogenous molecules including drugs and genetic material into vesicles and living cells. In addition, electroporation can be applied to induce fusion between vesicles and/or cells. First, we discuss in detail how research on cell-size GUVs as model cell systems has provided novel insight into the basic mechanisms of cell electroporation and associated phenomena. Afterwards, we continue with a thorough overview how electroporation and electrofusion have been used as versatile methods to manipulate vesicles of all sizes in different biomedical applications. We conclude by summarizing the open questions in the field of electroporation and possible future directions for vesicles in the biomedical field.
Collapse
|
21
|
Chen JWE, Pedron S, Harley BAC. The Combined Influence of Hydrogel Stiffness and Matrix-Bound Hyaluronic Acid Content on Glioblastoma Invasion. Macromol Biosci 2017; 17:10.1002/mabi.201700018. [PMID: 28379642 PMCID: PMC5555785 DOI: 10.1002/mabi.201700018] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2017] [Indexed: 12/28/2022]
Abstract
Glioblastoma (GBM) is the most common and lethal form of brain cancer. Its high mortality is associated with its aggressive invasion throughout the brain. The heterogeneity of stiffness and hyaluronic acid (HA) content within the brain makes it difficult to study invasion in vivo. A dextran-bead assay is employed to quantify GBM invasion within HA-functionalized gelatin hydrogels. Using a library of stiffness-matched hydrogels with variable levels of matrix-bound HA, it is reported that U251 GBM invasion is enhanced in softer hydrogels but reduced in the presence of matrix-bound HA. Inhibiting HA-CD44 interactions reduces invasion, even in hydrogels lacking matrix-bound HA. Analysis of HA biosynthesis suggests that GBM cells compensate for a lack of matrix-bound HA by producing soluble HA to stimulate invasion. Together, a robust method is showed to quantify GBM invasion over long culture times to reveal the coordinated effect of matrix stiffness, immobilized HA, and compensatory HA production on GBM invasion.
Collapse
Affiliation(s)
- Jee-Wei Emily Chen
- Department of Chemical and Biomolecular Engineering, University of Illinois at Urbana-Champaign, 600 S. Mathews St., Urbana, IL, 61801, USA
| | - Sara Pedron
- Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, 1206 W. Gregory Dr., Urbana, IL, 61801, USA
| | - Brendan A C Harley
- Department of Chemical and Biomolecular Engineering, and Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, 600 S. Mathews St., Urbana, IL, 61801, USA
| |
Collapse
|
22
|
Gupta S, Wang WS, Vanapalli SA. Microfluidic viscometers for shear rheology of complex fluids and biofluids. BIOMICROFLUIDICS 2016; 10:043402. [PMID: 27478521 PMCID: PMC4947045 DOI: 10.1063/1.4955123] [Citation(s) in RCA: 58] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2016] [Accepted: 06/21/2016] [Indexed: 05/20/2023]
Abstract
The rich diversity of man-made complex fluids and naturally occurring biofluids is opening up new opportunities for investigating their flow behavior and characterizing their rheological properties. Steady shear viscosity is undoubtedly the most widely characterized material property of these fluids. Although widely adopted, macroscale rheometers are limited by sample volumes, access to high shear rates, hydrodynamic instabilities, and interfacial artifacts. Currently, microfluidic devices are capable of handling low sample volumes, providing precision control of flow and channel geometry, enabling a high degree of multiplexing and automation, and integrating flow visualization and optical techniques. These intrinsic advantages of microfluidics have made it especially suitable for the steady shear rheology of complex fluids. In this paper, we review the use of microfluidics for conducting shear viscometry of complex fluids and biofluids with a focus on viscosity curves as a function of shear rate. We discuss the physical principles underlying different microfluidic viscometers, their unique features and limits of operation. This compilation of technological options will potentially serve in promoting the benefits of microfluidic viscometry along with evincing further interest and research in this area. We intend that this review will aid researchers handling and studying complex fluids in selecting and adopting microfluidic viscometers based on their needs. We conclude with challenges and future directions in microfluidic rheometry of complex fluids and biofluids.
Collapse
Affiliation(s)
- Siddhartha Gupta
- Department of Chemical Engineering, Texas Tech University , Lubbock, Texas 79409, USA
| | - William S Wang
- Department of Chemical Engineering, Texas Tech University , Lubbock, Texas 79409, USA
| | - Siva A Vanapalli
- Department of Chemical Engineering, Texas Tech University , Lubbock, Texas 79409, USA
| |
Collapse
|
23
|
|
24
|
|