Hsiao CY, Yang PC, Huang KW. Linear radiofrequency ablation using dual switching-control mode achieves rapid and bloodless liver resection, an experimental research. Int J Hyperthermia 2021; 38:357-362. [PMID: 33641575 DOI: 10.1080/02656736.2021.1892215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
Abstract
BACKGROUND Radiofrequency (RF)-assisted devices are widely used for hemostasis during liver resection. This study compared the use of dual switching (DS) versus single switching (SS) control modes for RF-based liver resections in a pig model. METHODS The RF-based system comprised a 200-W generator and three electrodes with 4-cm tips arranged in a linear configuration using an adaptor. Eight Lanyu pigs were used to assess ablation outcomes with electrode spacing of 2 or 3 cm, and ablation durations of 1.5, 2 or 3 min. All combinations were tested in DS and SS modes. Procedures were performed on left lateral, caudal and right anterior liver lobes, and after which transections were performed using a scalpel. Blood loss, complete ablation rate and ablation speed were compared. RESULTS DS mode was shown to induce significantly less blood loss than SS mode when the electrode spacing was set at 2 cm and the ablation duration was 2 min or 3 min (p=.010 and .012, respectively). Extended ablation duration and narrow electrode spacing tended to induce less blood loss, regardless of operating mode. Bloodless resection was achieved using DS mode with electrode spacing of 2 cm and ablation duration of 2-3 min. The highest rate of complete ablation (11.3 cm2/min) was achieved using DS mode with electrode spacing of 2 cm and ablation duration of 1.5 min. CONCLUSION RF-based hepatic resection using DS mode is safe and feasible, resulting in less blood loss than SS mode with a higher rate of complete ablation (i.e., superior ablation efficiency).
Collapse
Affiliation(s)
- Chih-Yang Hsiao
- College of Medicine, Graduate Institute of Clinical Medicine, National Taiwan University, Taipei, Taiwan.,Department of Surgery, National Taiwan University Hospital, Taipei, Taiwan.,Department of Traumatology, National Taiwan University Hospital, Taipei, Taiwan
| | - Po-Chih Yang
- College of Medicine, Graduate Institute of Clinical Medicine, National Taiwan University, Taipei, Taiwan.,Center for Organ Transplantation and Liver Disease Treatment, Fu Jen Catholic University Hospital, New Taipei City, Taiwan
| | - Kai-Wen Huang
- College of Medicine, Graduate Institute of Clinical Medicine, National Taiwan University, Taipei, Taiwan.,Department of Surgery, National Taiwan University Hospital, Taipei, Taiwan.,Hepatitis Research Center, National Taiwan University Hospital, Taipei, Taiwan.,Centre of Mini-invasive Interventional Oncology, National Taiwan University Hospital, Taipei, Taiwan
| |
Collapse
|
2
|
Hui TCH, Brace CL, Hinshaw JL, Quek LHH, Huang IKH, Kwan J, Lim GHT, Lee FT, Pua U. Microwave ablation of the liver in a live porcine model: the impact of power, time and total energy on ablation zone size and shape. Int J Hyperthermia 2020; 37:668-676. [DOI: 10.1080/02656736.2020.1774083] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Affiliation(s)
| | - Christopher Lee Brace
- Department of Radiology and Biomedical Engineering, University of Wisconsin, Madison, WI, USA
| | - J. Louis Hinshaw
- Department of Radiology and Urology, University of Wisconsin, Madison, WI, USA
| | | | | | - Justin Kwan
- Department of Diagnostic Radiology, Tan Tock Seng Hospital, Singapore, Singapore
| | - Gavin Hock Tai Lim
- Department of Diagnostic Radiology, Tan Tock Seng Hospital, Singapore, Singapore
| | - Fred T. Lee
- Department of Diagnostic Radiology, Tan Tock Seng Hospital, Singapore, Singapore
- Department of Radiology and Urology, University of Wisconsin, Madison, WI, USA
| | - Uei Pua
- Department of Diagnostic Radiology, Tan Tock Seng Hospital, Singapore, Singapore
| |
Collapse
|
3
|
Kho ASK, Foo JJ, Ooi ET, Ooi EH. Shape-shifting thermal coagulation zone during saline-infused radiofrequency ablation: A computational study on the effects of different infusion location. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2020; 184:105289. [PMID: 31891903 DOI: 10.1016/j.cmpb.2019.105289] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2019] [Revised: 12/07/2019] [Accepted: 12/19/2019] [Indexed: 06/10/2023]
Abstract
BACKGROUND AND OBJECTIVE The majority of the studies on radiofrequency ablation (RFA) have focused on enlarging the size of the coagulation zone. An aspect that is crucial but often overlooked is the shape of the coagulation zone. The shape is crucial because the majority of tumours are irregularly-shaped. In this paper, the ability to manipulate the shape of the coagulation zone following saline-infused RFA by altering the location of saline infusion is explored. METHODS A 3D model of the liver tissue was developed. Saline infusion was described using the dual porosity model, while RFA was described using the electrostatic and bioheat transfer equations. Three infusion locations were investigated, namely at the proximal end, the middle and the distal end of the electrode. Investigations were carried out numerically using the finite element method. RESULTS Results indicated that greater thermal coagulation was found in the region of tissue occupied by the saline bolus. Infusion at the middle of the electrode led to the largest coagulation volume followed by infusion at the proximal and distal ends. It was also found that the ability to delay roll-off, as commonly associated with saline-infused RFA, was true only for the case when infusion is carried out at the middle. When infused at the proximal and distal ends, the occurrence of roll-off was advanced. This may be due to the rapid and more intense heating experienced by the tissue when infusion is carried out at the electrode ends where Joule heating is dominant. CONCLUSION Altering the location of saline infusion can influence the shape of the coagulation zone following saline-infused RFA. The ability to 'shift' the coagulation zone to a desired location opens up great opportunities for the development of more precise saline-infused RFA treatment that targets specific regions within the tissue.
Collapse
Affiliation(s)
- Antony S K Kho
- School of Engineering, Monash University Malaysia, Jalan Lagoon Selatan, Bandar Sunway 47500, Selangor, Malaysia
| | - Ji J Foo
- School of Engineering, Monash University Malaysia, Jalan Lagoon Selatan, Bandar Sunway 47500, Selangor, Malaysia
| | - Ean T Ooi
- School of Engineering and Information Technology, Faculty of Science and Technology, Federation University, VIC 3350, Australia
| | - Ean H Ooi
- School of Engineering, Monash University Malaysia, Jalan Lagoon Selatan, Bandar Sunway 47500, Selangor, Malaysia; Advanced Engineering Platform, Monash University Malaysia, Jalan Lagoon Selatan, Bandar Sunway 47500, Selangor, Malaysia.
| |
Collapse
|
4
|
Ben-David E, Nissenbaum I, Gurevich S, Cosman ER, Goldberg SN. Optimization and characterization of a novel internally-cooled radiofrequency ablation system with optimized pulsing algorithm in an ex-vivo bovine liver. Int J Hyperthermia 2019; 36:81-88. [DOI: 10.1080/02656736.2019.1617901] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] Open
Affiliation(s)
- Eliel Ben-David
- Department of Radiology, Shaare Zedek Medical Center, Jerusalem, Israel
| | - Isaac Nissenbaum
- Department of Radiology, Hadassah Hebrew University Medical Center, Jerusalem, Israel
| | - Svetlana Gurevich
- Department of Radiology, Hadassah Hebrew University Medical Center, Jerusalem, Israel
| | | | - S. Nahum Goldberg
- Department of Radiology, Hadassah Hebrew University Medical Center, Jerusalem, Israel
| |
Collapse
|
5
|
Jiang AN, Wang S, Yang W, Zhao K, Bai XM, Zhang ZY, Wu W, Chen MH, Yan K. The Role of a Curved Electrode with Controllable Direction in the Radiofrequency Ablation of Liver Tumors Behind Large Vessels. Cardiovasc Intervent Radiol 2019; 42:893-904. [PMID: 30761411 DOI: 10.1007/s00270-019-02182-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2018] [Accepted: 02/05/2019] [Indexed: 01/16/2023]
Abstract
PURPOSE To investigate the role of a novel curved radiofrequency ablation (RFA) electrode with controllable direction in the ablation of tumors behind large hepatic vessels in ex vivo bovine and in vivo canine liver experiments. MATERIALS AND METHODS Approval from the institutional animal care and use committee was obtained. In ex vivo experiments, conventional multi-tines expandable electrodes, conventional monopolar straight electrodes and novel curved electrodes were used in the ablation of the bovine liver (n = 90). The ablated area, parallel axis, vertical axis and shape of different electrodes were compared. Then, 24 beagle dogs (10 months old, female) were used for in vivo experiments. Visual tumor targets deeply located in the portal vein were established, and ultrasound-guided liver ablation was performed with different electrodes. The ablation range, target coverage rate, percentage of normal tissue injury and damage to adjacent vessels were evaluated. The Kruskal-Wallis test and the Chi-squared test were used for statistical analysis. RESULTS For the ex vivo study with a 3-cm electrode, the ablation area of the multi-tines expandable electrode group (7.14 ± 0.16 cm2) was significantly larger than that of the novel curved electrode group (5.01 ± 0.30 cm2, P < 0.001) and the monopolar straight electrode group (5.43 ± 0.15 cm2, P < 0.001). The results obtained with the 4-cm electrode in the three groups were in accordance with those of the 3-cm electrode. In vivo, the normal tissue damage area of the novel curved electrode group was smaller than that of the multi-tines expandable electrode group (1.10 ± 0.18 cm2 vs. 4.00 ± 0.18 cm2, P < 0.001). The target coverage rate of the novel curved electrode group was better than that of the monopolar straight electrode group (100% vs. 80.86 ± 1.68%, P < 0.001). The hematoxylin and eosin (H&E) and TUNEL staining results showed that the ablation necrosis area was adjacent to large vessels, but the vascular wall was not significantly damaged in the novel curved electrode group. CONCLUSION Our preliminary results showed that the novel curved RFA electrode with controllable direction could achieve accurate ablation for tumors behind large hepatic vessels, with a better target coverage rate and less damage to normal tissue, than conventional multi-tines expandable electrodes and monopolar straight electrodes.
Collapse
Affiliation(s)
- An-Na Jiang
- Department of Ultrasound, Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Peking University Cancer Hospital and Institute, 52 Fucheng Road, Haidian District, Beijing, 100142, China
| | - Song Wang
- Department of Ultrasound, Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Peking University Cancer Hospital and Institute, 52 Fucheng Road, Haidian District, Beijing, 100142, China
| | - Wei Yang
- Department of Ultrasound, Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Peking University Cancer Hospital and Institute, 52 Fucheng Road, Haidian District, Beijing, 100142, China.
| | - Kun Zhao
- Department of Ultrasound, Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Peking University Cancer Hospital and Institute, 52 Fucheng Road, Haidian District, Beijing, 100142, China
| | - Xiu-Mei Bai
- Department of Ultrasound, Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Peking University Cancer Hospital and Institute, 52 Fucheng Road, Haidian District, Beijing, 100142, China
| | - Zhong-Yi Zhang
- Department of Ultrasound, Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Peking University Cancer Hospital and Institute, 52 Fucheng Road, Haidian District, Beijing, 100142, China
| | - Wei Wu
- Department of Ultrasound, Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Peking University Cancer Hospital and Institute, 52 Fucheng Road, Haidian District, Beijing, 100142, China
| | - Min-Hua Chen
- Department of Ultrasound, Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Peking University Cancer Hospital and Institute, 52 Fucheng Road, Haidian District, Beijing, 100142, China
| | - Kun Yan
- Department of Ultrasound, Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Peking University Cancer Hospital and Institute, 52 Fucheng Road, Haidian District, Beijing, 100142, China
| |
Collapse
|
6
|
Tsui PH, Wang CY, Zhou Z, Wan YL. Monitoring Radiofrequency Ablation Using Ultrasound Envelope Statistics and Shear Wave Elastography in the Periablation Period: An In Vitro Feasibility Study. PLoS One 2016; 11:e0162488. [PMID: 27603012 PMCID: PMC5014384 DOI: 10.1371/journal.pone.0162488] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2016] [Accepted: 08/02/2016] [Indexed: 01/03/2023] Open
Abstract
Radiofrequency ablation (RFA) is a minimally invasive method for treating tumors. Shear wave elastography (SWE) has been widely applied in evaluating tissue stiffness and final ablation size after RFA. However, the usefulness of periablation SWE imaging in assessing RFA remains unclear. Therefore, this study investigated the correlation between periablation SWE imaging and final ablation size. An in vitro porcine liver model was used for experimental validation (n = 36). During RFA with a power of 50 W, SWE images were collected using a clinical ultrasound system. To evaluate the effects of tissue temperature and gas bubbles during RFA, changes in the ablation temperature were recorded, and image echo patterns were measured using B-mode and ultrasound statistical parametric images. After RFA, the gross pathology of each tissue sample was compared with the region of change in the corresponding periablation SWE image. The experimental results showed that the tissue temperature at the ablation site varied between 70°C and 100°C. Hyperechoic regions and changes were observed in the echo amplitude distribution induced by gas bubbles. Under this condition, the confounding effects (including the temperature increase, tissue stiffness increase, and presence of gas bubbles) resulted in artifacts in the periablation SWE images, and the corresponding region correlated with the estimated final ablation size obtained from the gross pathology (r = 0.8). The findings confirm the feasibility of using periablation SWE imaging in assessing RFA.
Collapse
Affiliation(s)
- Po-Hsiang Tsui
- Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan
- Medical Imaging Research Center, Institute for Radiological Research, Chang Gung University and Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan
- Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan
- * E-mail: (PHT); (YLW)
| | - Chiao-Yin Wang
- Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan
- Graduate Institute of Clinical Medical Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan
| | - Zhuhuang Zhou
- College of Life Science and Bioengineering, Beijing University of Technology, Beijing, China
| | - Yung-Liang Wan
- Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan
- Medical Imaging Research Center, Institute for Radiological Research, Chang Gung University and Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan
- Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan
- * E-mail: (PHT); (YLW)
| |
Collapse
|
7
|
Schwenke M, Strehlow J, Haase S, Jenne J, Tanner C, Langø T, Loeve AJ, Karakitsios I, Xiao X, Levy Y, Sat G, Bezzi M, Braunewell S, Guenther M, Melzer A, Preusser T. An integrated model-based software for FUS in moving abdominal organs. Int J Hyperthermia 2015; 31:240-50. [DOI: 10.3109/02656736.2014.1002817] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
|
8
|
Yoon JH, Lee JM, Hwang EJ, Hwang IP, Baek J, Han JK, Choi BI. Monopolar radiofrequency ablation using a dual-switching system and a separable clustered electrode: evaluation of the in vivo efficiency. Korean J Radiol 2014; 15:235-44. [PMID: 24643383 PMCID: PMC3955790 DOI: 10.3348/kjr.2014.15.2.235] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2013] [Accepted: 01/11/2014] [Indexed: 01/18/2023] Open
Abstract
OBJECTIVE To determine the in vivo efficiency of monopolar radiofrequency ablation (RFA) using a dual-switching (DS) system and a separable clustered (SC) electrode to create coagulation in swine liver. MATERIALS AND METHODS Thirty-three ablation zones were created in nine pigs using a DS system and an SC electrode in the switching monopolar mode. The pigs were divided into two groups for two experiments: 1) preliminary experiments (n = 3) to identify the optimal inter-electrode distances (IEDs) for dual-switching monopolar (DSM)-RFA, and 2) main experiments (n = 6) to compare the in vivo efficiency of DSM-RFA with that of a single-switching monopolar (SSM)-RFA. RF energy was alternatively applied to one of the three electrodes (SSM-RFA) or concurrently applied to a pair of electrodes (DSM-RFA) for 12 minutes in in vivo porcine livers. The delivered RFA energy and the shapes and dimensions of the coagulation areas were compared between the two groups. RESULTS No pig died during RFA. The ideal IEDs for creating round or oval coagulation area using the DSM-RFA were 2.0 and 2.5 cm. DSM-RFA allowed more efficient RF energy delivery than SSM-RFA at the given time (23.0 ± 4.0 kcal vs. 16.92 ± 2.0 kcal, respectively; p = 0.0005). DSM-RFA created a significantly larger coagulation volume than SSM-RFA (40.4 ± 16.4 cm(3) vs. 20.8 ± 10.7 cm(3); p < 0.001). Both groups showed similar circularity of the ablation zones (p = 0.29). CONCLUSION Dual-switching monopolar-radiofrequency ablation using an SC electrode is feasible and can create larger ablation zones than SSM-RFA as it allows more RF energy delivery at a given time.
Collapse
Affiliation(s)
- Jeong Hee Yoon
- Department of Radiology, Seoul National University Hospital, Seoul 110-744, Korea
| | - Jeong Min Lee
- Department of Radiology, Seoul National University Hospital, Seoul 110-744, Korea. ; Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul 110-744, Korea
| | - Eui Jin Hwang
- Department of Radiology, Seoul National University Hospital, Seoul 110-744, Korea
| | - In Pyung Hwang
- Department of Radiology, Seoul National University Hospital, Seoul 110-744, Korea
| | - Jeehyun Baek
- Department of Radiology, Seoul National University Hospital, Seoul 110-744, Korea
| | - Joon Koo Han
- Department of Radiology, Seoul National University Hospital, Seoul 110-744, Korea. ; Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul 110-744, Korea
| | - Byung Ihn Choi
- Department of Radiology, Seoul National University Hospital, Seoul 110-744, Korea. ; Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul 110-744, Korea
| |
Collapse
|
9
|
Appelbaum L, Ben-David E, Faroja M, Nissenbaum Y, Sosna J, Goldberg SN. Irreversible electroporation ablation: creation of large-volume ablation zones in in vivo porcine liver with four-electrode arrays. Radiology 2013; 270:416-24. [PMID: 24126371 DOI: 10.1148/radiol.13130349] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
PURPOSE To prospectively determine optimal parameters with which to achieve defined large target zones of coagulation by using irreversible electroporation (IRE) with four-electrode arrays and the time needed to achieve this treatment effect in an in vivo animal model. MATERIALS AND METHODS This study was approved by the animal care and use committee. Ultrasonography (US)-guided IRE ablation (n = 90) was performed in vivo in 69 pig livers with an array of four electrodes (18 gauge) and an electroporation generator. Cardiac-gated 100-µsec IRE pulses were applied sequentially between the six sets of electrode pairs at 2250-3000 V. Multiple algorithms of energy deposition and electrode configuration were studied, including interelectrode spacing (1.5-2.5 cm), number of IRE pulses applied consecutively to each electrode pair (10, 20, 50, and 100), and number of times per cycle each electrode pair was activated (one to 10). Resultant zones of treatment were measured with US 1.5-3 hours after IRE and confirmed at gross and histopathologic examination. Data and ablation times were compared to determine the optimal algorithms with which to achieve 4-7-cm areas of treatment effect in the shortest time possible. In addition, the IRE current applied was correlated with ablation size. Data were analyzed by using analysis of variance with multiple comparisons, t tests, or nonparametric statistics. RESULTS For 2.5-cm spacing, ablation diameter was increased by increasing either the overall time of energy application or the number of cycles of 20 pulses (P < .01 for both). IRE application of less than four cycles (or continuous IRE application of 100 pulses) did not result in contiguous ablation. However, sequentially increasing the number of cycles of IRE from four to 10 increased both the electrical current applied (from 14.4 A ± 0.4 to 17.6 A ± 0.7, P = .0004) and ablation diameter (from 5.6 cm ± 0.3 to 6.6 cm ± 0.3, P = .001). Although division of application into cycles did not alter coagulation at 2.0- and 1.5-cm spacing, application of energy to diagonal electrode pairs increased coagulation. Thus, one 100-pulse cycle (11.0 minutes ± 1.4) produced 4.8 cm ± 0.3 of ablation for 2.0-cm spacing with diagonal pairs but only 4.1 cm ± 0.3 of ablation without diagonal pairs (7.5 minutes ± 1.0, P < .03 for both). CONCLUSION With four-electrode arrays, IRE can create large contiguous zones of treatment effect in clinically acceptable ablation times; parameters can be tailored to achieve a wide range of ablation sizes. Cyclical deposition of IRE application is beneficial, particularly for larger interprobe spacing, most likely owing to alterations of electrical conductivity that occur after successive applications of IRE energy.
Collapse
Affiliation(s)
- Liat Appelbaum
- From the Departments of Radiology (L.A., E.B., Y.N., J.S., S.N.G.) and Surgery (M.F.), Hadassah Hebrew University Medical Center, Jerusalem, Israel 91120; and Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Mass (S.N.G.)
| | | | | | | | | | | |
Collapse
|
10
|
Zhang B, Moser M, Zhang E, Zhang WJ. Radiofrequency ablation technique in the treatment of liver tumours: review and future issues. J Med Eng Technol 2013; 37:150-9. [PMID: 23360198 DOI: 10.3109/03091902.2012.754510] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Thermal ablation is increasingly being used for treatment of liver tumours. Among the techniques of thermal ablation, radiofrequency ablation (RF) is undoubtedly being used most frequently because of its advantages, such as morbidity and mortality rates, effective tumour ablation, as well as being less time-consuming. This paper presents the state of the art of RF ablation technique. This includes the theoretical development, experimental study and clinical application of the radiofrequency ablation technique. First, it introduces the principle of this technique. Second, it shows the development of this technique and valuable achievements. These achievements include the device, strategy of operation and extension to other diseases. Third, it concludes future issues to be addressed in order to further advance this technique.
Collapse
Affiliation(s)
- B Zhang
- Department of Biomedical Engineering, University of Saskatchewan, Saskatoon, SK, Canada
| | | | | | | |
Collapse
|
11
|
Furse A, Miller BJ, McCann C, Kachura JR, Jewett MA, Sherar MD. Radiofrequency coil for the creation of large ablations: ex vivo and in vivo testing. J Vasc Interv Radiol 2013; 23:1522-8. [PMID: 23101925 DOI: 10.1016/j.jvir.2012.08.015] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2012] [Revised: 07/31/2012] [Accepted: 08/13/2012] [Indexed: 01/12/2023] Open
Abstract
PURPOSE Various radiofrequency (RF) ablation electrode designs have been developed to increase ablation volume. Multiple heating cycles and electrode positions are often required, thereby increasing treatment time. The objective of this study was to evaluate the performance of a high-frequency monopolar induction coil designed to produce large thermal lesions (>3 cm) with a single electrode insertion in a treatment time of less than 10 minutes. MATERIALS AND METHODS A monopolar nitinol interstitial coil operated at 27.12 MHz and 200 W was evaluated. Ex vivo performance was tested in excised bovine liver (n = 22). In vivo testing (n = 10) was conducted in livers of seven Yorkshire pigs. Visual inspection, contrast-enhanced computed tomography (CT), and pathologic evaluation of ablation zones were performed. RESULTS Average ablation volumes in ex vivo and in vivo tests were 60.5 cm(3) ± 14.1 (5.9 × 4.4 × 4.4 cm) and 57.1cm(3) ± 13.8 (6.1 × 4.5 × 4.1cm), with average treatment times of 9.0 minutes ± 3.0 and 8.4 minutes ± 2.7, respectively. Contrast-enhanced CT ablation volume measurements corresponded with findings of gross inspection. Pathologic analysis showed morphologic and enzymatic changes suggestive of tissue death within the ablation zones. CONCLUSIONS The RF ablation coil device successfully produced large, uniform ablation volumes in ex vivo and in vivo settings in treatment times of less than 10 minutes. Ex vivo and in vivo lesion sizes were not significantly different (P = .53), suggesting that the heating efficiency of this higher-frequency coil device may help to minimize the heat-sink effect of perfusion.
Collapse
Affiliation(s)
- Alex Furse
- Division of Biophysics and Bioimaging, Ontario Cancer Institute, Princess Margaret Hospital, University Health Network, Toronto, Ontario, Canada.
| | | | | | | | | | | |
Collapse
|
12
|
Characterization of irreversible electroporation ablation in in vivo porcine liver. AJR Am J Roentgenol 2012; 198:W62-8. [PMID: 22194517 DOI: 10.2214/ajr.11.6940] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
OBJECTIVE The purpose of this study was to prospectively characterize and optimize irreversible electroporation ablation to determine the best parameters to achieve the largest target zones of coagulation for two electrodes. MATERIALS AND METHODS Ultrasound-guided irreversible electroporation ablation (n=110) was performed in vivo in 25 pig livers using two 18-gauge electroporation electrodes and an irreversible electroporation generator. Five variables for energy deposition and electrode configuration were sequentially studied: number of electrical pulses (n=20-90), length of pulses (20-100 microseconds), generator voltage (2250-3000 V), interelectrode spacing (1.5-2.5 cm), and length of active electrode exposure (1.0-3.0 cm). Zones of ablation were determined at gross pathology and histopathology 2-3 hours after irreversible electroporation. Dimensions were compared and subjected to statistical analysis. RESULTS For 1.5-cm spacing and 2-cm electrode exposure at 2250 V, there was no statistical difference in the size of coagulation when varying the number or length of pulses from 50 to 90 repetitions or 50-100 microseconds, respectively, with each parameter combination yielding 3.0±0.4×1.7±0.4×3.0±0.6 cm (width, depth, and height, respectively). Yet, increasing the pulse width or number over 70 caused increased hyperechogenic or gas and coagulation around the electrode. Increasing the voltage from 2250-3000 V for 70 pulses of 70 microseconds increased coagulation to 3.1±0.4×2.0±0.2 cm (p<0.01 for depth). Greater coagulation width of 3.9±0.5 cm (p<0.01) was achieved at 2-cm interelectrode spacing (with similar depth of 1.9±0.4 cm). However, consistent results required 90 repetitions and a 100-microsecond pulse width; 2.5-cm spacing resulted in two separate zones of ablation. Although electrode exposure did not influence width or depth, a linear correlation (r2=0.77) was noted for height, which ranged from 2.0±0.2-5.0±0.8 cm (for 1- and 3-cm exposures, respectively). CONCLUSION Predictable zones of tissue destruction can be achieved for irreversible electroporation. Ablation dimensions are sensitive to multiple parameters, suggesting that precise technique and attention to detail will be particularly important when using this modality.
Collapse
|
13
|
Ahmed M, Moussa M, Goldberg SN. Synergy in cancer treatment between liposomal chemotherapeutics and thermal ablation. Chem Phys Lipids 2011; 165:424-37. [PMID: 22197685 DOI: 10.1016/j.chemphyslip.2011.12.002] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2011] [Revised: 12/05/2011] [Accepted: 12/06/2011] [Indexed: 01/03/2023]
Abstract
Minimally invasive image-guided tumor ablation using short duration heating via needle-like applicators using energies such as radiofrequency or microwave has seen increasing clinical use to treat focal liver, renal, breast, bone, and lung tumors. Potential benefits of this thermal therapy include reduced morbidity and mortality compared to standard surgical resection and ability to treat non-surgical patients. However, improvements to this technique are required as achieving complete ablation in many cases can be challenging particularly at margins of tumors>3 cm in diameter and adjacent to blood vessels. Thus, one very promising strategy has been to combine thermal tumor ablation with adjuvant nanoparticle-based chemotherapy agents to improve efficiency. Here, we will primarily review principles of thermal ablation to provide a framework for understanding the mechanisms of combination therapy, and review the studies on combination therapy, including presenting preliminary data on the role of such variables as nanoparticle size and thermal dose on improving combination therapy outcome. We will discuss how thermal ablation can also be used to improve overall intratumoral drug accumulation and nanoparticle content release. Finally, in this article we will further describe the appealing off-shoot approach of utilizing thermal ablation techniques not as the primary treatment, but rather, as a means to improve efficiency of intratumoral nanoparticle drug delivery.
Collapse
Affiliation(s)
- Muneeb Ahmed
- Minimally Invasive Tumor Therapy Laboratory, Section of Interventional Radiology, Department of Radiology, Beth Israel Deaconess Medical Center/Harvard Medical School, 330 Brookline Ave, Boston, MA 02215, USA.
| | | | | |
Collapse
|
14
|
Koda M, Tokunaga S, Matono T, Sugihara T, Nagahara T, Murawaki Y. Comparison between different thickness umbrella-shaped expandable radiofrequency electrodes (SuperSlim and CoAccess): Experimental and clinical study. Exp Ther Med 2011; 2:1215-1220. [PMID: 22977647 DOI: 10.3892/etm.2011.347] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2011] [Accepted: 08/24/2011] [Indexed: 11/06/2022] Open
Abstract
The purpose of the present study was to compare the size and configuration of the ablation zones created by SuperSlim and CoAccess electrodes, using various ablation algorithms in ex vivo bovine liver and in clinical cases. In the experimental study, we ablated explanted bovine liver using 2 types of electrodes and 4 ablation algorithms (combinations of incremental power supply, stepwise expansion and additional low-power ablation) and evaluated the ablation area and time. In the clinical study, we compared the ablation volume and the shape of the ablation zone between both electrodes in 23 hepatocellular carcinoma (HCC) cases with the best algorithm (incremental power supply, stepwise expansion and additional low-power ablation) as derived from the experimental study. In the experimental study, the ablation area and time by the CoAccess electrode were significantly greater compared to those by the SuperSlim electrode for the single-step (algorithm 1, p=0.0209 and 0.0325, respectively) and stepwise expansion algorithms (algorithm 2, p=0.0002 and <0.0001, respectively; algorithm 3, p= 0.006 and 0.0407, respectively). However, differences were not significant for the additional low-power ablation algorithm. In the clinical study, the ablation volume and time in the CoAccess group were significantly larger and longer, respectively, compared to those in the SuperSlim group (p=0.0242 and 0.009, respectively). Round ablation zones were acquired in 91.7% of the CoAccess group, while irregular ablation zones were obtained in 45.5% of the SuperSlim group (p=0.0428). In conclusion, the CoAccess electrode achieves larger and more uniform ablation zones compared with the SuperSlim electrode, though it requires longer ablation times in experimental and clinical studies.
Collapse
Affiliation(s)
- Masahiko Koda
- Second Department of Internal Medicine, School of Medicine, Tottori University, Yonago 683-8504, Japan
| | | | | | | | | | | |
Collapse
|
15
|
Pua BB, Thornton RH, Solomon SB. Radiofrequency Ablation: Treatment of Primary Lung Cancer. Semin Roentgenol 2011; 46:224-9. [DOI: 10.1053/j.ro.2011.02.006] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
16
|
|