1
|
Narsinh KH, Young C, Chen SR, Ansari SA, Kan P, Hetts SW. Neurointerventional oncology: the new frontier. J Neurointerv Surg 2025:jnis-2025-023050. [PMID: 39880620 DOI: 10.1136/jnis-2025-023050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/19/2025] [Indexed: 01/31/2025]
Affiliation(s)
- Kazim H Narsinh
- Radiology & Neurosurgery, University of California San Francisco, San Francisco, California, USA
| | - Christopher Young
- Neurosurgery, The University of Texas Medical Branch at Galveston, Galveston, Texas, USA
| | - Stephen R Chen
- Radiology & Neurosurgery, University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Sameer A Ansari
- Radiology, Neurosurgery, Neurology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Peter Kan
- Neurosurgery, The University of Texas Medical Branch at Galveston, Galveston, Texas, USA
| | - Steven W Hetts
- Radiology & Neurosurgery, University of California San Francisco, San Francisco, California, USA
| |
Collapse
|
2
|
Delgado JF, Negussie AH, Varble NA, Mikhail AS, Arrichiello A, Borde T, Saccenti L, Bakhutashvili I, Owen JW, Morhard R, Karanian JW, Pritchard WF, Wood BJ. In vivo imaging and pharmacokinetics of percutaneously injected ultrasound and X-ray imageable thermosensitive hydrogel loaded with doxorubicin versus free drug in swine. PLoS One 2024; 19:e0310345. [PMID: 39700200 DOI: 10.1371/journal.pone.0310345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2024] [Accepted: 11/11/2024] [Indexed: 12/21/2024] Open
Abstract
Intratumoral injections often lack visibility, leading to unpredictable outcomes such as incomplete tumor coverage, off-target drug delivery and systemic toxicities. This study investigated an ultrasound (US) and x-ray imageable thermosensitive hydrogel based on poloxamer 407 (POL) percutaneously delivered in a healthy swine model. The primary objective was to assess the 2D and 3D distribution of the hydrogel within tissue across three different needle devices and injection sites: liver, kidney, and intercostal muscle region. Secondly, pharmacokinetics of POL loaded with doxorubicin (POLDOX) were evaluated and compared to free doxorubicin injection (DOXSoln) with a Single End Hole Needle. Utilizing 2D and 3D morphometrics from US and x-ray imaging techniques such as Computed Tomography (CT) and Cone Beam CT (CBCT), we monitored the localization and leakage of POLDOX over time. Relative iodine concentrations measured with CBCT following incorporation of an iodinated contrast agent in POL indicated potential drug diffusion and advection transport. Furthermore, US imaging revealed temporal changes, suggesting variations in acoustic intensity, heterogeneity, and echotextures. Notably, 3D reconstruction of the distribution of POL and POLDOX from 2D ultrasound frames was achieved and morphometric data obtained. Pharmacokinetic analysis revealed lower systemic exposure of the drug in various organs with POLDOX formulation compared to DOXSoln formulation. This was demonstrated by a lower area under the curve (852.1 ± 409.1 ng/mL·h vs 2283.4 ± 377.2 ng/mL·h) in the plasma profile, suggesting a potential reduction in systemic toxicity. Overall, the use of POL formulation offers a promising strategy for precise and localized drug delivery, that may minimize adverse effects. Dual modality POL imaging enabled analysis of patterns of gel distribution and morphology, alongside of pharmacokinetics of local delivery. Incorporating hydrogels into drug delivery systems holds significant promise for improving the predictability of the delivered drug and enhancing spatial conformability. These advancements can potentially enhance the safety and precision of anticancer therapy.
Collapse
Affiliation(s)
- Jose F Delgado
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD, United States of America
- Fischell Department of Bioengineering, A. James Clark School of Engineering, University of Maryland, College Park, Maryland, United States of America
| | - Ayele H Negussie
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD, United States of America
| | - Nicole A Varble
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD, United States of America
- Philips Healthcare, Cambridge, Massachusetts, United States of America
| | - Andrew S Mikhail
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD, United States of America
| | - Antonio Arrichiello
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD, United States of America
- Department of Diagnostic and Interventional Radiology, UOS of Interventional Ra `1diology, Ospedale Maggiore di Lodi, Lodi, Italy
| | - Tabea Borde
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD, United States of America
| | - Laetitia Saccenti
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD, United States of America
| | - Ivane Bakhutashvili
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD, United States of America
| | - Joshua W Owen
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD, United States of America
| | - Robert Morhard
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD, United States of America
| | - John W Karanian
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD, United States of America
| | - William F Pritchard
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD, United States of America
| | - Bradford J Wood
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD, United States of America
- Fischell Department of Bioengineering, A. James Clark School of Engineering, University of Maryland, College Park, Maryland, United States of America
| |
Collapse
|
3
|
Pal K, Awad A, Yevich S, Kuban JD, Tam AL, Huang SY, Odisio BC, Gupta S, Habibollahi P, Bishop AJ, Conley AP, Somaiah N, Araujo D, Zarzour MA, Ravin R, Roland CL, Keung EZ, Sheth RA. Safety and Efficacy of Percutaneous Cryoablation for Recurrent or Metastatic Soft-Tissue Sarcoma in Adult Patients. AJR Am J Roentgenol 2024; 223:e2431490. [PMID: 39082849 DOI: 10.2214/ajr.24.31490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/09/2024]
Abstract
BACKGROUND. Treatment options are limited in patients with recurrent or metastatic disease after initial treatment of soft-tissue sarcoma (STS) by surgical resection, radiation, or systemic therapy. Percutaneous cryoablation may provide a complementary minimally invasive option in this setting. OBJECTIVE. The purpose of this article was to assess the safety and efficacy of percutaneous cryoablation performed for local control of treatment-refractory recurrent or metastatic STS. METHODS. This single-institution retrospective study included adult patients who underwent percutaneous cryoablation from January 2016 to April 2023 to achieve local control of recurrent or metastatic STS after earlier treatment (surgery, radiation, or chemotherapy). For each treated lesion, a single interventional radiologist rereviewed intraprocedural images to assess for adequate coverage by the ice ball of the entire lesion and a 5-mm or greater margin in all dimensions. Complications and outcomes were extracted from medical records. The primary end point for procedure efficacy was 1-year local progression-free survival. RESULTS. The study included 141 patients (median age, 66 years; 90 women, 51 men) who underwent 217 cryoablation procedures to treat 250 recurrent or metastatic STS lesions. The most common STS histologic types were leiomyosarcoma (56/141) and liposarcoma (39/141). Lesions had a mean long-axis diameter of 2.0 cm (range, 0.4-11.0 cm). Adequate ice-ball coverage was achieved for 82% (204/250) of lesions. The complication rate was 2% (4/217), including three major complications and one minor complication. Patients' median postablation follow-up was 25 months (range, 3-80 months). Local progression-free survival rate was 86% at 1 year and 80% at 2 years. The chemotherapy-free survival rate was 45% at 1 year and 31% at 2 years. The overall survival (OS) rate was 89% at 1 year and 80% at 2 years. In Kaplan-Meier analysis, leiomyosarcoma, in comparison with liposarcoma, had significantly higher local progression-free survival but no significant difference in OS. In multivariable analysis, factors independently associated with an increased risk for local progression included inadequate ice-ball coverage (HR = 7.34) and a lesion location of peritoneum (HR = 3.63) or retroperitoneum (HR = 3.71) relative to lung. CONCLUSION. Percutaneous cryoablation has a favorable safety and efficacy profile in patients with recurrent or metastatic STS after earlier treatments. CLINICAL IMPACT. Percutaneous cryoablation should be considered for local control of treatment-refractory STS.
Collapse
Affiliation(s)
- Koustav Pal
- Department of Interventional Radiology, University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Unit 1471, Houston, TX 77030-4009
| | - Ahmed Awad
- Department of Interventional Radiology, University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Unit 1471, Houston, TX 77030-4009
| | - Steven Yevich
- Department of Interventional Radiology, University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Unit 1471, Houston, TX 77030-4009
| | - Joshua D Kuban
- Department of Interventional Radiology, University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Unit 1471, Houston, TX 77030-4009
| | - Alda L Tam
- Department of Interventional Radiology, University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Unit 1471, Houston, TX 77030-4009
| | - Steven Y Huang
- Department of Interventional Radiology, University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Unit 1471, Houston, TX 77030-4009
| | - Bruno C Odisio
- Department of Interventional Radiology, University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Unit 1471, Houston, TX 77030-4009
| | - Sanjay Gupta
- Department of Interventional Radiology, University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Unit 1471, Houston, TX 77030-4009
| | - Peiman Habibollahi
- Department of Interventional Radiology, University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Unit 1471, Houston, TX 77030-4009
| | - Andrew J Bishop
- Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX
| | - Anthony P Conley
- Department of Sarcoma Medical Oncology, University of Texas MD Anderson Cancer Center, Houston, TX
| | - Neeta Somaiah
- Department of Sarcoma Medical Oncology, University of Texas MD Anderson Cancer Center, Houston, TX
| | - Dejka Araujo
- Department of Sarcoma Medical Oncology, University of Texas MD Anderson Cancer Center, Houston, TX
| | - Maria A Zarzour
- Department of Sarcoma Medical Oncology, University of Texas MD Anderson Cancer Center, Houston, TX
| | - Ratan Ravin
- Department of Sarcoma Medical Oncology, University of Texas MD Anderson Cancer Center, Houston, TX
| | - Christina L Roland
- Department of Surgical Oncology, University of Texas MD Anderson Cancer Center, Houston, TX
| | - Emily Z Keung
- Department of Surgical Oncology, University of Texas MD Anderson Cancer Center, Houston, TX
| | - Rahul A Sheth
- Department of Interventional Radiology, University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Unit 1471, Houston, TX 77030-4009
| |
Collapse
|
4
|
Delgado JF, Negussie AH, Varble NA, Mikhail AS, Arrichiello A, Borde T, Saccenti L, Bakhutashvili I, Owen JW, Morhard R, Karanian JW, Pritchard WF, Wood BJ. In vivo Imaging and Pharmacokinetics of Percutaneously Injected Ultrasound and X-ray Imageable Thermosensitive Hydrogel loaded with Doxorubicin versus Free Drug in Swine. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.09.01.610710. [PMID: 39282453 PMCID: PMC11398325 DOI: 10.1101/2024.09.01.610710] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 10/25/2024]
Abstract
Intratumoral injections often lack visibility, leading to unpredictable outcomes such as incomplete tumor coverage, off-target drug delivery and systemic toxicities. This study investigated an ultrasound (US) and x-ray imageable thermosensitive hydrogel based on poloxamer 407 (POL) percutaneously delivered in a healthy swine model. The primary objective was to assess the 2D and 3D distribution of the hydrogel within tissue across three different needle devices and injection sites: liver, kidney, and intercostal muscle region. Secondly, pharmacokinetics of POL loaded with doxorubicin (POLDOX) were evaluated and compared to free doxorubicin injection (DOXSoln) with a Single End Hole Needle. Utilizing 2D and 3D morphometrics from US and x-ray imaging techniques such as Computed Tomography (CT) and Cone Beam CT (CBCT), we monitored the localization and leakage of POLDOX over time. Relative iodine concentrations measured with CBCT following incorporation of an iodinated contrast agent in POL indicated potential drug diffusion and advection transport. Furthermore, US imaging revealed temporal changes, suggesting variations in acoustic intensity, heterogeneity, and echotextures. Notably, 3D reconstruction of the distribution of POL and POLDOX from 2D ultrasound frames was achieved and morphometric data obtained. Pharmacokinetic analysis revealed lower systemic exposure of the drug in various organs with POLDOX formulation compared to DOXSoln formulation. This was demonstrated by a lower area under the curve (852.1 ± 409.1 ng/mL·h vs 2283.4 ± 377.2 ng/mL·h) in the plasma profile, suggesting a potential reduction in systemic toxicity. Overall, the use of POL formulation offers a promising strategy for precise and localized drug delivery, that may minimize adverse effects. Dual modality POL imaging enabled analysis of patterns of gel distribution and morphology, alongside of pharmacokinetics of local delivery. Incorporating hydrogels into drug delivery systems holds significant promise for improving the predictability of the delivered drug and enhancing spatial conformability. These advancements can potentially enhance the safety and precision of anticancer therapy.
Collapse
Affiliation(s)
- Jose F. Delgado
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD
- Fischell Department of Bioengineering, A. James Clark School of Engineering, University of Maryland, College Park, MD
| | - Ayele H. Negussie
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD
| | - Nicole A. Varble
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD
- Philips Healthcare, Cambridge, MA
| | - Andrew S. Mikhail
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD
| | - Antonio Arrichiello
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD
- UOS of Interventional Radiology, Department of Diagnostic and Interventional Radiology, Ospedale Maggiore di Lodi, Largo Donatori del Sangue, Lodi, Italy
| | - Tabea Borde
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD
| | - Laetitia Saccenti
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD
| | - Ivane Bakhutashvili
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD
| | - Joshua W. Owen
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD
| | - Robert Morhard
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD
| | - John W. Karanian
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD
| | - William F. Pritchard
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD
| | - Bradford J. Wood
- Center for Interventional Oncology, Clinical Center, National Institutes of Health, Bethesda, MD
- Fischell Department of Bioengineering, A. James Clark School of Engineering, University of Maryland, College Park, MD
| |
Collapse
|
5
|
Delgado JF, Pritchard WF, Varble N, Lopez-Silva TL, Arrichiello A, Mikhail AS, Morhard R, Ray T, Havakuk MM, Nguyen A, Borde T, Owen JW, Schneider JP, Karanian JW, Wood BJ. X-ray imageable, drug-loaded hydrogel that forms at body temperature for image-guided, needle-based locoregional drug delivery. Sci Rep 2024; 14:13352. [PMID: 38858467 PMCID: PMC11164888 DOI: 10.1038/s41598-024-64189-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2024] [Accepted: 06/06/2024] [Indexed: 06/12/2024] Open
Abstract
Liver cancer ranks as the fifth leading cause of cancer-related death globally. Direct intratumoral injections of anti-cancer therapeutics may improve therapeutic efficacy and mitigate adverse effects compared to intravenous injections. Some challenges of intratumoral injections are that the liquid drug formulation may not remain localized and have unpredictable volumetric distribution. Thus, drug delivery varies widely, highly-dependent upon technique. An X-ray imageable poloxamer 407 (POL)-based drug delivery gel was developed and characterized, enabling real-time feedback. Utilizing three needle devices, POL or a control iodinated contrast solution were injected into an ex vivo bovine liver. The 3D distribution was assessed with cone beam computed tomography (CBCT). The 3D distribution of POL gels demonstrated localized spherical morphologies regardless of the injection rate. In addition, the gel 3D conformal distribution could be intentionally altered, depending on the injection technique. When doxorubicin (DOX) was loaded into the POL and injected, DOX distribution on optical imaging matched iodine distribution on CBCT suggesting spatial alignment of DOX and iodine localization in tissue. The controllability and localized deposition of this formulation may ultimately reduce the dependence on operator technique, reduce systemic side effects, and facilitate reproducibility across treatments, through more predictable standardized delivery.
Collapse
Affiliation(s)
- Jose F Delgado
- National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, MD, USA.
- Fischell Department of Bioengineering, University of Maryland, College Park, MD, USA.
| | - William F Pritchard
- National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, MD, USA
| | - Nicole Varble
- National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, MD, USA
- Philips Healthcare, Cambridge, MA, USA
| | - Tania L Lopez-Silva
- Chemical Biology Laboratory, National Cancer Institute, National Institutes of Health, Center for Cancer Research, Frederick, MD, USA
| | - Antonio Arrichiello
- National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, MD, USA
- UOS of Interventional Radiology, Department of Diagnostic and Interventional Radiology, Ospedale Maggiore di Lodi, Largo Donatori del Sangue, Lodi, Italy
| | - Andrew S Mikhail
- National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, MD, USA
| | - Robert Morhard
- National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, MD, USA
| | - Trisha Ray
- National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, MD, USA
| | - Michal M Havakuk
- National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, MD, USA
- Interventional Radiology Department, Tel-Aviv Sourasky Medical Center, Tel-Aviv, Israel
| | - Alex Nguyen
- National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, MD, USA
- Computer Science Department, Stanford University, Stanford, CA, USA
| | - Tabea Borde
- National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, MD, USA
| | - Joshua W Owen
- National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, MD, USA
| | - Joel P Schneider
- Chemical Biology Laboratory, National Cancer Institute, National Institutes of Health, Center for Cancer Research, Frederick, MD, USA
| | - John W Karanian
- National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, MD, USA
| | - Bradford J Wood
- National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, MD, USA
- Fischell Department of Bioengineering, University of Maryland, College Park, MD, USA
| |
Collapse
|
6
|
Liu J, Guo Y, Sun Y, Liu M, Zhang X, Zheng R, Cong L, Liu B, Xie X, Huang G. Three-dimensional ultrasound fusion imaging in precise needle placement for thermal ablation of hepatocellular carcinoma. Int J Hyperthermia 2024; 41:2316097. [PMID: 38360570 DOI: 10.1080/02656736.2024.2316097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Accepted: 02/03/2024] [Indexed: 02/17/2024] Open
Abstract
PURPOSE To investigate the value of three-dimensional ultrasound fusion imaging (3DUS FI) technique for guiding needle placement in hepatocellular carcinoma (HCC) thermal ablation. METHODS A total of 57 patients with 60 HCCs with 3DUS FI-guided thermal ablation were retrospectively included in the study. 3DUS volume data of liver were acquired preoperatively by freehand scanning with the tumor and predetermined 5 mm ablative margin automatically segmented. Plan of needle placement was made through a predetermined simulated ablation zone to ensure a 5 mm ablative margin with the coverage rate toward tumor and ablative margin. With real-time ultrasound and 3DUS fusion imaging, ablation needles were placed according to the plan. After ablation, the ablative margin was immediately evaluated by contrast-enhanced ultrasound and 3DUS fusion imaging. The rate of adequate ablative margin, complete response (CR), local tumor progression (LTP), disease-free survival (DFS), and overall survival (OS) was evaluated. RESULTS According to postoperative contrast-enhanced CT or MR imaging, the complete response rate was 100% (60/60), and 83% of tumors (30/36) achieved adequate ablative margin (>5 mm) three-dimensionally. During the follow-up period of 6.0-42.6 months, LTP occurred in 5 lesions, with 1- and 2-year LTP rates being 7.0% and 9.4%. The 1- and 2-year DFS rates were 76.1% and 65.6%, and 1- and 2-year OS rates were 98.1% and 94.0%. No major complications or ablation-related deaths were observed in any patients. CONCLUSIONS Three-dimensional ultrasound fusion imaging technique may improve the needle placement of thermal ablation for HCC and reduce the rate of LTP.
Collapse
Affiliation(s)
- Jiaming Liu
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Yuqing Guo
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
- Department of Ultrasound, Huadong Hospital, Fudan University, Shanghai, China
| | - Yueting Sun
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Ming Liu
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Xiaoer Zhang
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Ruiying Zheng
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Longfei Cong
- Medical Imaging System Division, Shenzhen Mindray Bio-Medical Electronics Co., Ltd, Shenzhen, China
| | - Baoxian Liu
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Xiaoyan Xie
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Guangliang Huang
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
- Department of Medical Ultrasonics, Guangxi Hospital Division of the First Affiliated Hospital, Sun Yat-Sen University, Nanning, China
| |
Collapse
|
7
|
Muglia R, Marra P, Pinelli D, Dulcetta L, Carbone FS, Barbaro A, Celestino A, Colledan M, Sironi S. Technical and Clinical Outcomes of Laparoscopic-Laparotomic Hepatocellular Carcinoma Thermal Ablation with Microwave Technology: Case Series and Review of Literature. Cancers (Basel) 2023; 16:92. [PMID: 38201536 PMCID: PMC10778313 DOI: 10.3390/cancers16010092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Revised: 12/21/2023] [Accepted: 12/23/2023] [Indexed: 01/12/2024] Open
Abstract
PURPOSE To evaluate technical and clinical outcomes of intraoperative (laparoscopic/laparotomic) microwave ablation on HCC. MATERIALS AND METHODS This is a retrospective single-center study evaluating consecutive patients treated for very early/early-stage HCC with intraoperative microwave ablation from 1 July 2017 to 30 June 2023. In these patients, a percutaneous US-guided approach was excluded due to the nodule's suboptimal visibility or harmful location and liver resection for a deep position or adherences. Data about the clinical stage, surgical approach, liver pathology and nodules characteristics, technical success, complications, and follow-up were collected. Technical success was intended as the absence of locoregional persistence at follow-up CT/MRI controls. RESULTS A total of 36 cirrhotic patients (M:F = 30:6, median age 67 years) were enrolled; 18/36 (50%) had a single nodule, 13/36 (36%) had two, 4/36 had three (11%), and 1/36 had four (3%). Among the patients, 24 (67%) were treated with laparoscopy, and 12/36 (33%) with a laparotomic approach. Sixty HCCs of 16.5 mm (6-50 mm) were treated for 7 min (2-30 min) with 100 W of power. A total of 55 nodules (92%) were treated successfully and showed no residual enhancement at the first postoperative follow-up; the other 5/60 (8%) underwent chemo/radioembolization. There was one complication (3%): a biliary fistula treated with percutaneous drainage and glue embolization. The average hospital stay was 3.5 days (1-51 days), and patients were followed up on average for 238 days (13-1792 days). During follow-up, 5/36 patients (14%) underwent liver transplantation, 1/36 (2%) died during hospitalization and 1 after discharge. CONCLUSIONS Laparoscopic/laparotomic intraoperative HCC MW ablation is feasible in patients unsuitable for percutaneous approach or hepatic resection, with rare complications and with good technical and clinical outcomes.
Collapse
Affiliation(s)
- Riccardo Muglia
- Department of Radiology, Papa Giovanni XXIII Hospital, 24127 Bergamo, Italy; (P.M.); (L.D.); (F.S.C.)
- School of Medicine, University of Milano-Bicocca, 20126 Milano, Italy (A.C.)
| | - Paolo Marra
- Department of Radiology, Papa Giovanni XXIII Hospital, 24127 Bergamo, Italy; (P.M.); (L.D.); (F.S.C.)
- School of Medicine, University of Milano-Bicocca, 20126 Milano, Italy (A.C.)
| | - Domenico Pinelli
- Department of General Surgery, Papa Giovanni XXIII Hospital, 24127 Bergamo, Italy; (D.P.); (M.C.)
| | - Ludovico Dulcetta
- Department of Radiology, Papa Giovanni XXIII Hospital, 24127 Bergamo, Italy; (P.M.); (L.D.); (F.S.C.)
| | - Francesco Saverio Carbone
- Department of Radiology, Papa Giovanni XXIII Hospital, 24127 Bergamo, Italy; (P.M.); (L.D.); (F.S.C.)
| | - Alessandro Barbaro
- School of Medicine, University of Milano-Bicocca, 20126 Milano, Italy (A.C.)
| | - Antonio Celestino
- School of Medicine, University of Milano-Bicocca, 20126 Milano, Italy (A.C.)
| | - Michele Colledan
- Department of General Surgery, Papa Giovanni XXIII Hospital, 24127 Bergamo, Italy; (D.P.); (M.C.)
| | - Sandro Sironi
- Department of Radiology, Papa Giovanni XXIII Hospital, 24127 Bergamo, Italy; (P.M.); (L.D.); (F.S.C.)
- School of Medicine, University of Milano-Bicocca, 20126 Milano, Italy (A.C.)
| |
Collapse
|
8
|
Biondetti P, Ierardi AM, Casiraghi E, Caruso A, Grillo P, Carriero S, Lanza C, Angileri SA, Sangiovanni A, Iavarone M, Guzzardi G, Carrafiello G. Clinical Impact of a Protocol Involving Cone-Beam CT (CBCT), Fusion Imaging and Ablation Volume Prediction in Percutaneous Image-Guided Microwave Ablation in Patients with Hepatocellular Carcinoma Unsuitable for Standard Ultrasound (US) Guidance. J Clin Med 2023; 12:7598. [PMID: 38137667 PMCID: PMC10743619 DOI: 10.3390/jcm12247598] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 11/02/2023] [Accepted: 11/04/2023] [Indexed: 12/24/2023] Open
Abstract
PURPOSE to evaluate the clinical impact of a protocol for the image-guided percutaneous microwave ablation (MWA) of hepatocellular carcinoma (HCC) that includes cone-beam computed tomography (CBCT), fusion imaging and ablation volume prediction in patients with hepatocellular carcinoma unsuitable for standard ultrasound (US) guidance. MATERIALS AND METHODS this study included all patients with HCC treated with MWA between January 2021 and June 2022 in a tertiary institution. Patients were divided into two groups: Group A, treated following the protocol, and Group B, treated with standard ultrasound (US) guidance. Follow-up images were reviewed to assess residual disease (RD), local tumor progression (LTP) and intrahepatic distant recurrence (IDR). Ablation response at 1 month was also evaluated according to mRECIST. Baseline variables and outcomes were compared between the groups. For 1-month RD, propensity score weighting (PSW) was performed. RESULTS 80 consecutive patients with 101 HCCs treated with MWA were divided into two groups. Group A had 41 HCCs in 37 patients, and Group B had 60 HCCs in 43 patients. Among all baseline variables, the groups differed regarding their age (mean of 72 years in Group A and 64 years in Group B, respectively), new vs. residual tumor rates (48% Group A vs. 25% Group B, p < 0.05) and number of subcapsular tumors (56.7% Group B vs. 31.7% Group A, p < 0.05) and perivascular tumors (51.7% Group B vs. 17.1% Group A, p < 0.05). The protocol led to repositioning the antenna in 49% of cases. There was a significant difference in 1-month local response between the groups measured as the RD rate and mRECIST outcomes. LTP rates at 3 and 6 months, and IDR rates at 1, 3 and 6 months, showed no significant differences. Among all variables, logistic regression after PSW demonstrated a protective effect of the protocol against 1-month RD. CONCLUSIONS The use of CBCT, fusion imaging and ablation volume prediction during percutaneous MWA of HCCs provided a better 1-month tumor local control. Further studies with a larger population and longer follow-up are needed.
Collapse
Affiliation(s)
- Pierpaolo Biondetti
- Facoltà di Medicina e Chirurgia, Università degli Studi di Milano, Via Festa del Perdono 7, 20122 Milan, Italy (A.C.); (M.I.); (G.C.)
- Department of Diagnostic and Interventional Radiology, Foundation IRCCS Cà Granda—Ospedale Maggiore Policlinico, Via Francesco Sforza 35, 20122 Milan, Italy; (A.M.I.); (P.G.); (S.A.A.)
| | - Anna Maria Ierardi
- Department of Diagnostic and Interventional Radiology, Foundation IRCCS Cà Granda—Ospedale Maggiore Policlinico, Via Francesco Sforza 35, 20122 Milan, Italy; (A.M.I.); (P.G.); (S.A.A.)
| | - Elena Casiraghi
- AnacletoLab, Computer Science Department “Giovanni degli Antoni”-DI, Università degli Studi di Milano, 20133 Milan, Italy;
- CINI National Laboratory in Artificial Intelligence and Intelligent Systems, 00185 Rome, Italy
| | - Alessandro Caruso
- Facoltà di Medicina e Chirurgia, Università degli Studi di Milano, Via Festa del Perdono 7, 20122 Milan, Italy (A.C.); (M.I.); (G.C.)
| | - Pasquale Grillo
- Department of Diagnostic and Interventional Radiology, Foundation IRCCS Cà Granda—Ospedale Maggiore Policlinico, Via Francesco Sforza 35, 20122 Milan, Italy; (A.M.I.); (P.G.); (S.A.A.)
| | - Serena Carriero
- Postgraduate School in Radiodiagnostics, Università degli Studi di Milano, 20122 Milan, Italy;
| | - Carolina Lanza
- Postgraduate School in Radiodiagnostics, Università degli Studi di Milano, 20122 Milan, Italy;
| | - Salvatore Alessio Angileri
- Department of Diagnostic and Interventional Radiology, Foundation IRCCS Cà Granda—Ospedale Maggiore Policlinico, Via Francesco Sforza 35, 20122 Milan, Italy; (A.M.I.); (P.G.); (S.A.A.)
| | - Angelo Sangiovanni
- Department of Gastroenterology and Hepatology, Foundation IRCCS Cà Granda–Ospedale Maggiore Policlinico, Via Francesco Sforza 35, 20122 Milan, Italy;
| | - Massimo Iavarone
- Facoltà di Medicina e Chirurgia, Università degli Studi di Milano, Via Festa del Perdono 7, 20122 Milan, Italy (A.C.); (M.I.); (G.C.)
- Department of Gastroenterology and Hepatology, Foundation IRCCS Cà Granda–Ospedale Maggiore Policlinico, Via Francesco Sforza 35, 20122 Milan, Italy;
| | - Giuseppe Guzzardi
- Department of Radiology, Unit of Interventional Radiology, Ospedale Maggiore della Carità, Corso Giuseppe Mazzini 18, 28100 Novara, Italy;
| | - Gianpaolo Carrafiello
- Facoltà di Medicina e Chirurgia, Università degli Studi di Milano, Via Festa del Perdono 7, 20122 Milan, Italy (A.C.); (M.I.); (G.C.)
- Department of Diagnostic and Interventional Radiology, Foundation IRCCS Cà Granda—Ospedale Maggiore Policlinico, Via Francesco Sforza 35, 20122 Milan, Italy; (A.M.I.); (P.G.); (S.A.A.)
| |
Collapse
|
9
|
Gómez FM, Van der Reijd DJ, Panfilov IA, Baetens T, Wiese K, Haverkamp-Begemann N, Lam SW, Runge JH, Rice SL, Klompenhouwer EG, Maas M, Helmberger T, Beets-Tan RG. Imaging in interventional oncology, the better you see, the better you treat. J Med Imaging Radiat Oncol 2023; 67:895-902. [PMID: 38062853 DOI: 10.1111/1754-9485.13610] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Accepted: 11/22/2023] [Indexed: 01/14/2024]
Abstract
Imaging and image processing is the fundamental pillar of interventional oncology in which diagnostic, procedure planning, treatment and follow-up are sustained. Knowing all the possibilities that the different image modalities can offer is capital to select the most appropriate and accurate guidance for interventional procedures. Despite there is a wide variability in physicians preferences and availability of the different image modalities to guide interventional procedures, it is important to recognize the advantages and limitations for each of them. In this review, we aim to provide an overview of the most frequently used image guidance modalities for interventional procedures and its typical and future applications including angiography, computed tomography (CT) and spectral CT, magnetic resonance imaging, Ultrasound and the use of hybrid systems. Finally, we resume the possible role of artificial intelligence related to image in patient selection, treatment and follow-up.
Collapse
Affiliation(s)
- Fernando M Gómez
- Grupo de Investigación Biomédica en Imagen, Instituto de Investigación Sanitaria La Fe, Valencia, Spain
- Área Clínica de Imagen Médica, Hospital Universitario y Politécnico La Fe, Valencia, Spain
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | | | - Ilia A Panfilov
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Tarik Baetens
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Kevin Wiese
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | | | - Siu W Lam
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Jurgen H Runge
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Samuel L Rice
- Radiology, Interventional Radiology Section, UT Southwestern Medical Center, Dallas, TX, USA
| | | | - Monique Maas
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Thomas Helmberger
- Institut für Radiologie, Neuroradiologie und Minimal-Invasive Therapie, München Klinik Bogenhausen, Munich, Germany
| | - Regina Gh Beets-Tan
- Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
- GROW School for Oncology and Developmental Biology, University of Maastricht, Maastricht, The Netherlands
| |
Collapse
|
10
|
van der Lei S, Opperman J, Dijkstra M, Kors N, Boon R, van den Bemd BAT, Timmer FEF, Nota IMGC, van den Bergh JE, de Vries JJJ, Scheffer HJ, Geboers B, Neuss T, Schouten E, Lissenberg-Witte BI, Puijk RS, Meijerink MR. The Added Diagnostic Value of Transcatheter CT Hepatic Arteriography for Intraprocedural Detection of Previously Unknown Colorectal Liver Metastases During Percutaneous Ablation and Impact on the Definitive Treatment Plan. Cardiovasc Intervent Radiol 2023; 46:1257-1266. [PMID: 37491521 PMCID: PMC10471708 DOI: 10.1007/s00270-023-03508-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Accepted: 06/29/2023] [Indexed: 07/27/2023]
Abstract
PURPOSE This study assessed the diagnostic value of CT hepatic arteriography (CTHA) for the intraprocedural detection of previously unknown colorectal liver metastases (CRLM) and the impact on the definitive treatment plan. MATERIALS AND METHODS All patients treated with CTHA-guided percutaneous ablation for CRLM between January 2012 and March 2022 were identified from the Amsterdam Colorectal Liver Met Registry (AmCORE). Radiology reports of the ablative procedure and follow-up imaging were reviewed to see if (a) previously unknown CRLM were detected intra-procedurally and if (b) new CRLM, potentially missed on CTHA, appeared within 6 months following the procedure; three abdominal radiologists re-reviewed the baseline CTHA scans of these patients with early recurrence. To ratify immediate ablations of concomitantly detected CRLM, the upper limit of false positives was predefined at 10%. RESULTS One hundred and fifty-two patients were included. With CTHA, a total of 17 additional tumours in 15 patients were diagnosed and treated immediately, two representing disappeared tumours following systemic chemotherapy. Compared to the conventional contrast-enhanced (ce)CT, ceMRI and 18F-FDG PET-CT, adding CTHA was superior for the detection of CRLM (P < .001). Within 12 months of follow-up 121, new CRLM appeared in 49/152 patients (32.2%); retrospective blinded assessment revealed 56 to already be visible on the baseline CTHA scan (46%); four lesions without substrate on follow-up scans were considered false positives (n = 4/60; 7%). Arterial ring enhancement was the most frequently reported imaging characteristic (n = 45/60; 75%). CONCLUSION The subsequent use of CTHA has added value for the detection of previously unknown and vanished CRLM. Taking into account the low number of false positives (7%) and the favourable safety profile of percutaneous ablation, we believe that immediate ablation of typical ring-enhancing supplementary tumours is justified and sufficiently validated. LEVEL OF EVIDENCE Level 3; individual cross-sectional study with consistently applied reference standard and blinding.
Collapse
Affiliation(s)
- Susan van der Lei
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, VU Medical Center Amsterdam, Cancer Center Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands.
| | - Jip Opperman
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, VU Medical Center Amsterdam, Cancer Center Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
- NWZ Group, Alkmaar, The Netherlands
| | - Madelon Dijkstra
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, VU Medical Center Amsterdam, Cancer Center Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
| | - Nikita Kors
- Cancer Center Amsterdam, Amsterdam, The Netherlands
| | - Rianne Boon
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, VU Medical Center Amsterdam, Cancer Center Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
| | - Bente A T van den Bemd
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, VU Medical Center Amsterdam, Cancer Center Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
| | - Florentine E F Timmer
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, VU Medical Center Amsterdam, Cancer Center Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
| | - Irene M G C Nota
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, VU Medical Center Amsterdam, Cancer Center Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
| | - Janneke E van den Bergh
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, VU Medical Center Amsterdam, Cancer Center Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
| | - Jan J J de Vries
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, VU Medical Center Amsterdam, Cancer Center Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
- OLVG Hospital, Amsterdam, The Netherlands
| | - Hester J Scheffer
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, VU Medical Center Amsterdam, Cancer Center Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
| | - Bart Geboers
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, VU Medical Center Amsterdam, Cancer Center Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
| | - Timothy Neuss
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, VU Medical Center Amsterdam, Cancer Center Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
| | - Evelien Schouten
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, VU Medical Center Amsterdam, Cancer Center Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
| | - Birgit I Lissenberg-Witte
- Department of Epidemiology and Data Science, Amsterdam University Medical Centers, VU Medical Center Amsterdam, Amsterdam, The Netherlands
| | - Robbert S Puijk
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, VU Medical Center Amsterdam, Cancer Center Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
- OLVG Hospital, Amsterdam, The Netherlands
| | - Martijn R Meijerink
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, VU Medical Center Amsterdam, Cancer Center Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
- NWZ Group, Alkmaar, The Netherlands
| |
Collapse
|
11
|
Chen Z, Meng L, Zhang J, Zhang X. Progress in the cryoablation and cryoimmunotherapy for tumor. Front Immunol 2023; 14:1094009. [PMID: 36761748 PMCID: PMC9907027 DOI: 10.3389/fimmu.2023.1094009] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Accepted: 01/09/2023] [Indexed: 01/26/2023] Open
Abstract
With the rapid advancement of imaging equipment and minimally invasive technology, cryoablation technology is being used more frequently in minimally invasive treatment of tumors, primarily for patients with early tumors who voluntarily consent to ablation as well as those with advanced tumors that cannot be surgically removed or cannot be tolerated. Cryoablation is more effective and secure for target lesions than other thermal ablation methods like microwave and radiofrequency ablation (RFA). The study also discovered that cryoablation, in addition to causing tumor tissue necrosis and apoptosis, can facilitate the release of tumor-derived autoantigens into the bloodstream and activate the host immune system to elicit beneficial anti-tumor immunological responses against primary. This may result in regression of the primary tumor and distant metastasis. The additional effect called " Accompanying effects ". It is the basis of combined ablation and immunotherapy for tumor. At present, there is a lot of research on the mechanism of immune response induced by cryoablation. Trying to solve the question: how positively induce immune response. In this review, we focus on: 1. the immune effects induced by cryoablation. 2. the effect and mechanism of tumor immunotherapy combined with cryoablation. 3.The clinical research of this combination therapy in the treatment of tumors.
Collapse
Affiliation(s)
- Zenan Chen
- Department of Radiology, The First Medical Center, Chinese People's Liberation Army (PLA) General Hospital, Beijing, China
| | - Liangliang Meng
- Department of Radiology, The First Medical Center, Chinese People's Liberation Army (PLA) General Hospital, Beijing, China.,Department of Radiology, Chinese People's Armed Police (PAP) Force Hospital of Beijing, Beijing, China
| | - Jing Zhang
- Department of Radiology, The First Medical Center, Chinese People's Liberation Army (PLA) General Hospital, Beijing, China
| | - Xiao Zhang
- Department of Radiology, The First Medical Center, Chinese People's Liberation Army (PLA) General Hospital, Beijing, China
| |
Collapse
|
12
|
Relationship between anxiety and internet searches before percutaneous ultrasound-guided diagnostic procedures: A prospective cohort study. PLoS One 2022; 17:e0275200. [PMID: 36194589 PMCID: PMC9531823 DOI: 10.1371/journal.pone.0275200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Accepted: 09/12/2022] [Indexed: 11/19/2022] Open
Abstract
Invasive procedures guided by ultrasound (US) are part of routine medical diagnostic investigation. The lack of knowledge surrounding the technical aspects of such procedures can lead patients to seek complementary information on the Internet, which may in turn trigger anxiety. However, the intersection between the fields of Radiology and Psychology is poorly studied. Here, we identify the profile of an anxious patient before an US-guided intervention. We prospectively studied 133 patients undergoing image-guided procedures. The State-Trait Anxiety Inventory (STAI) was applied for psychometry. Significantly higher anxiety scores were observed in female patients (p = .001), those who believed they had received inadequate information from their referring physician (p = .006), and in patients who considered online information unreliable or difficult to access (p = .007 and p = .001, respectively). Participants who defined themselves as proactive online reported lower anxiety levels (p = .003).
Collapse
|
13
|
Floridi C, Cellina M, Irmici G, Bruno A, Rossini N, Borgheresi A, Agostini A, Bruno F, Arrigoni F, Arrichiello A, Candelari R, Barile A, Carrafiello G, Giovagnoni A. Precision Imaging Guidance in the Era of Precision Oncology: An Update of Imaging Tools for Interventional Procedures. J Clin Med 2022; 11:4028. [PMID: 35887791 PMCID: PMC9322069 DOI: 10.3390/jcm11144028] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 07/02/2022] [Accepted: 07/08/2022] [Indexed: 02/05/2023] Open
Abstract
Interventional oncology (IO) procedures have become extremely popular in interventional radiology (IR) and play an essential role in the diagnosis, treatment, and supportive care of oncologic patients through new and safe procedures. IR procedures can be divided into two main groups: vascular and non-vascular. Vascular approaches are mainly based on embolization and concomitant injection of chemotherapeutics directly into the tumor-feeding vessels. Percutaneous approaches are a type of non-vascular procedures and include percutaneous image-guided biopsies and different ablation techniques with radiofrequency, microwaves, cryoablation, and focused ultrasound. The use of these techniques requires precise imaging pretreatment planning and guidance that can be provided through different imaging techniques: ultrasound, computed tomography, cone-beam computed tomography, and magnetic resonance. These imaging modalities can be used alone or in combination, thanks to fusion imaging, to further improve the confidence of the operators and the efficacy and safety of the procedures. This article aims is to provide an overview of the available IO procedures based on clinical imaging guidance to develop a targeted and optimal approach to cancer patients.
Collapse
Affiliation(s)
- Chiara Floridi
- Department of Clinical, Special and Dental Sciences, University Politecnica delle Marche, 60126 Ancona, Italy; (A.B.); (N.R.); (A.A.); (A.G.)
- Division of Special and Pediatric Radiology, Department of Radiology, University Hospital “Umberto I—Lancisi—Salesi”, 60126 Ancona, Italy;
- Division of Interventional Radiology, Department of Radiological Sciences, University Politecnica Delle Marche, 60126 Ancona, Italy;
| | - Michaela Cellina
- Radiology Department, Fatebenefratelli Hospital, ASST Fatebenefratelli Sacco, 20122 Milan, Italy;
| | - Giovanni Irmici
- Post-Graduation School in Radiodiagnostics, Università degli Studi di Milano, 20122 Milan, Italy; (G.I.); (A.A.)
| | - Alessandra Bruno
- Department of Clinical, Special and Dental Sciences, University Politecnica delle Marche, 60126 Ancona, Italy; (A.B.); (N.R.); (A.A.); (A.G.)
| | - Nicolo’ Rossini
- Department of Clinical, Special and Dental Sciences, University Politecnica delle Marche, 60126 Ancona, Italy; (A.B.); (N.R.); (A.A.); (A.G.)
| | - Alessandra Borgheresi
- Division of Special and Pediatric Radiology, Department of Radiology, University Hospital “Umberto I—Lancisi—Salesi”, 60126 Ancona, Italy;
| | - Andrea Agostini
- Department of Clinical, Special and Dental Sciences, University Politecnica delle Marche, 60126 Ancona, Italy; (A.B.); (N.R.); (A.A.); (A.G.)
| | - Federico Bruno
- Department of Biotechnological and Applied Clinical Sciences, University of L’Aquila, 67100 L’Aquila, Italy; (F.B.); (A.B.)
| | - Francesco Arrigoni
- Emergency and Interventional Radiology, San Salvatore Hospital, 67100 L’Aquila, Italy;
| | - Antonio Arrichiello
- Post-Graduation School in Radiodiagnostics, Università degli Studi di Milano, 20122 Milan, Italy; (G.I.); (A.A.)
| | - Roberto Candelari
- Division of Interventional Radiology, Department of Radiological Sciences, University Politecnica Delle Marche, 60126 Ancona, Italy;
| | - Antonio Barile
- Department of Biotechnological and Applied Clinical Sciences, University of L’Aquila, 67100 L’Aquila, Italy; (F.B.); (A.B.)
| | - Gianpaolo Carrafiello
- Operative Unit of Radiology, Fondazione IRCCS Ca’ Granda Ospedale Maggiore Policlinico di Milano, 20122 Milan, Italy;
- Department of Health Sciences, Università degli Studi di Milano, 20122 Milan, Italy
| | - Andrea Giovagnoni
- Department of Clinical, Special and Dental Sciences, University Politecnica delle Marche, 60126 Ancona, Italy; (A.B.); (N.R.); (A.A.); (A.G.)
- Division of Special and Pediatric Radiology, Department of Radiology, University Hospital “Umberto I—Lancisi—Salesi”, 60126 Ancona, Italy;
| |
Collapse
|
14
|
Fite BZ, Wang J, Ghanouni P, Ferrara KW. A Review of Imaging Methods to Assess Ultrasound-Mediated Ablation. BME FRONTIERS 2022; 2022:9758652. [PMID: 35957844 PMCID: PMC9364780 DOI: 10.34133/2022/9758652] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Accepted: 02/21/2022] [Indexed: 12/18/2022] Open
Abstract
Ultrasound ablation techniques are minimally invasive alternatives to surgical resection and have rapidly increased in use. The response of tissue to HIFU ablation differs based on the relative contributions of thermal and mechanical effects, which can be varied to achieve optimal ablation parameters for a given tissue type and location. In tumor ablation, similar to surgical resection, it is desirable to include a safety margin of ablated tissue around the entirety of the tumor. A factor in optimizing ablative techniques is minimizing the recurrence rate, which can be due to incomplete ablation of the target tissue. Further, combining focal ablation with immunotherapy is likely to be key for effective treatment of metastatic cancer, and therefore characterizing the impact of ablation on the tumor microenvironment will be important. Thus, visualization and quantification of the extent of ablation is an integral component of ablative procedures. The aim of this review article is to describe the radiological findings after ultrasound ablation across multiple imaging modalities. This review presents readers with a general overview of the current and emerging imaging methods to assess the efficacy of ultrasound ablative treatments.
Collapse
Affiliation(s)
- Brett Z. Fite
- Department of Radiology, Stanford University, Palo Alto, CA 94305, USA
| | - James Wang
- Department of Radiology, Stanford University, Palo Alto, CA 94305, USA
| | - Pejman Ghanouni
- Department of Radiology, Stanford University, Palo Alto, CA 94305, USA
| | | |
Collapse
|
15
|
Pedersoli F, Wilkmann C, Penzkofer T, Disselhorst-Klug C, Schmitz-Rode T, Kuhl C, Bruners P, Isfort P. An accelerometer-based guidance device for CT-guided procedures: an improved wireless prototype. MINIM INVASIV THER 2021; 31:902-908. [PMID: 34865602 DOI: 10.1080/13645706.2021.2002363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
INTRODUCTION The aim of the study was to demonstrate the feasibility of a prototype for accelerometer-based guidance for percutaneous CT-guided punctures and compare it with free-hand punctures. MATERIAL AND METHODS The prototype enabled alignment with the CT coordinate system and a wireless connectivity. Its feasibility was tested in a swine cadaver model: 20 out-of-plane device-assisted punctures performed without intermittent control scans (one-step punctures) were evaluated regarding deviation to target and difference between planned and obtained angle. Thereafter, 22 device-assisted punctures were compared with 20 free-hand punctures regarding distance to target, deviation from the planned angle, number of control scans and procedure time. Differences were compared with the Mann-Whitney U-test (p < .05). RESULTS The one-step punctures revealed a deviation to target of 0.26 ± 0.37 cm (axial plane) and 0.21 ± 0.19 cm (sagittal plane) and differences between planned and performed puncture angles of 0.9 ± 1.09° (axial plane) and 1.15 ± 0.91° (sagittal planes). In the comparative study, device-assisted punctures showed a significantly higher accuracy, 0.20 ± 0.17 cm vs. 0.30 ± 0.21 cm (p < .05) and lower number of required control scans, 1.3 ± 1.1 vs. 3.7 ± 0.9 (p < .05) compared with free-hand punctures. CONCLUSION The accelerometer-based device proved to be feasible and demonstrated significantly higher accuracy and required significantly less control scans compared to free-hand puncture.
Collapse
Affiliation(s)
- Federico Pedersoli
- Department of Diagnostic and Interventional Radiology, RWTH Aachen University Hospital, Aachen, Germany
| | - Christoph Wilkmann
- Department of Diagnostic and Interventional Radiology, RWTH Aachen University Hospital, Aachen, Germany.,Institute of Applied Medical Engineering, Deptartment of Rehabilitation & Prevention Engineering, RWTH Aachen University, Aachen, Germany
| | - Tobias Penzkofer
- Department of Radiology, Charité Universitätsmedizin Berlin, Berlin, Germany.,Berlin Institute of Health, Berlin, Germany
| | - Catherine Disselhorst-Klug
- Institute of Applied Medical Engineering, Deptartment of Rehabilitation & Prevention Engineering, RWTH Aachen University, Aachen, Germany
| | - Thomas Schmitz-Rode
- Institute of Applied Medical Engineering, Deptartment of Rehabilitation & Prevention Engineering, RWTH Aachen University, Aachen, Germany
| | - Christiane Kuhl
- Department of Diagnostic and Interventional Radiology, RWTH Aachen University Hospital, Aachen, Germany
| | - Philipp Bruners
- Department of Diagnostic and Interventional Radiology, RWTH Aachen University Hospital, Aachen, Germany
| | - Peter Isfort
- Department of Diagnostic and Interventional Radiology, RWTH Aachen University Hospital, Aachen, Germany
| |
Collapse
|
16
|
Haroon M, Sathiadoss P, Hibbert RM, Jeyaraj SK, Lim C, Schieda N. Imaging considerations for thermal and radiotherapy ablation of primary and metastatic renal cell carcinoma. Abdom Radiol (NY) 2021; 46:5386-5407. [PMID: 34245341 DOI: 10.1007/s00261-021-03178-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Revised: 06/09/2021] [Accepted: 06/10/2021] [Indexed: 10/20/2022]
Abstract
Ablative (percutaneous and stereotactic) thermal and radiotherapy procedures for management of both primary and metastatic renal cell carcinoma are increasing in popularity in clinical practice. Data suggest comparable efficacy with lower cost and morbidity compared to nephrectomy. Ablative therapies may be used alone or in conjunction with surgery or chemotherapy for treatment of primary tumor and metastatic disease. Imaging plays a crucial role in pre-treatment selection and planning of ablation, intra-procedural guidance, evaluation for complications, short- and long-term post-procedural surveillance of disease, and treatment response. Treatment response and disease recurrence may differ considerably after ablation, particularly for stereotactic radiotherapy, when compared to conventional surgical and chemotherapies. This article reviews the current and emerging role of imaging for ablative therapy of renal cell carcinoma.
Collapse
|
17
|
Buijs M, de Bruin DM, Wagstaff PG, J Zondervan P, Scheltema MJV, W Engelbrecht M, P Laguna M, van Lienden KP. MRI and CT in the follow-up after irreversible electroporation of small renal masses. DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY (ANKARA, TURKEY) 2021; 27:654-663. [PMID: 34559050 DOI: 10.5152/dir.2021.19575] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
PURPOSE Ablation plays a growing role in the treatment of small renal masses (SRMs) due to its nephron sparing properties and low invasiveness. Irreversible electroporation (IRE) has the potential, although still experimental, to overcome current limitations of thermal ablation. No prospective imaging studies exist of the ablation zone in the follow up after renal IRE in humans. Objectives are to assess computed tomography (CT) and magnetic resonance imaging (MRI) on the ablation zone volume (AZV), enhancement and imaging characteristics after renal IRE. METHODS Prospective phase 2 study of IRE in nine patients with ten SRMs. MRI imaging was performed pre-IRE, 1 week, 3 months, 6 months and 12 months after IRE. CT was performed pre-IRE, perioperatively (direct after ablation), 3 months, 6 months and 12 months after IRE. AZVs were assessed by two independent observers. Observer variation was analyzed. Evolution of AZVs, and relation between the needle configuration volume (NCV; planned AZV) and CT- and MRI volumes were evaluated. RESULTS Eight SRMs were clear cell renal cell carcinomas, one SRM was a papillary renal cell carcinoma and one patient had a non-diagnostic biopsy. On CT, median AZV increased perioperatively until 3 months post-IRE (respectively, 16.8 cm3 and 6.2 cm3) compared to the NCV (4.8 cm3). On MRI, median AZV increased 1-week post-IRE until 3 months post-IRE (respectively, 14.5 cm3 and 4.6 cm3) compared to the NCV (4.8 cm3). At 6 months the AZV starts decreasing (CT 4.8 cm3; MRI 3.0 cm3), continuing at 12 months (CT 4.2 cm3, MRI 1.1 cm3). Strong correlation was demonstrated between the planning and the post-treatment volumes. Inter-observer agreement between observers was excellent (CT 95% CI 0.82-0.95, MRI 95% CI 0.86-0.96). All SRMs appeared non-enhanced immediately after ablation, except for one residual tumour. Subtraction images confirmed non-enhancement on MRI in unclear enhancement cases (3/9). Directly after IRE, gas bubbles, perinephric stranding and edema were observed in all cases. CONCLUSION The AZV increases immediately on CT until 3 months after IRE. On MRI, the AZV increases at 1 week until 3 months post-IRE. At 6 months the AZV starts decreasing until 12 months post-IRE on both CT and MRI. Enhancement was absent post-IRE, except for one residual tumour. Gas bubbles, perinephric stranding and edema are normal findings directly post-IRE.
Collapse
Affiliation(s)
- Mara Buijs
- Department of Urology, Academic Medical Center, Amsterdam, The Netherlands
| | - Daniel M de Bruin
- Department of Urology, Academic Medical Center, Amsterdam, The Netherlands; Department of Biomedical Engineering - Physics, Academic Medical Center, Amsterdam, The Netherlands
| | - Peter Gk Wagstaff
- Department of Urology, Academic Medical Center, Amsterdam, The Netherlands
| | | | | | - Marc W Engelbrecht
- Department of Radiology, Academic Medical Center, Amsterdam, The Netherlands
| | - Maria P Laguna
- Department of Urology, Istanbul Medipol University, Instanbul, Turkey
| | - Krijn P van Lienden
- Department of Radiology, Academic Medical Center, Amsterdam, The Netherlands
| |
Collapse
|
18
|
Pohlman RM, Hinshaw JL, Ziemlewicz TJ, Lubner MG, Wells SA, Lee FT, Alexander ML, Wergin KL, Varghese T. Differential Imaging of Liver Tumors before and after Microwave Ablation with Electrode Displacement Elastography. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:2138-2156. [PMID: 34011451 PMCID: PMC8243838 DOI: 10.1016/j.ultrasmedbio.2021.03.027] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2020] [Revised: 03/18/2021] [Accepted: 03/23/2021] [Indexed: 05/17/2023]
Abstract
Liver cancer is a leading cause of cancer-related deaths; however, primary treatment options such as surgical resection and liver transplant may not be viable for many patients. Minimally invasive image-guided microwave ablation (MWA) provides a locally effective treatment option for these patients with an impact comparable to that of surgery for both cancer-specific and overall survival. MWA efficacy is correlated with accurate image guidance; however, conventional modalities such as B-mode ultrasound and computed tomography have limitations. Alternatively, ultrasound elastography has been used to demarcate post-ablation zones, yet has limitations for pre-ablation visualization because of variability in strain contrast between cancer types. This study attempted to characterize both pre-ablation tumors and post-ablation zones using electrode displacement elastography (EDE) for 13 patients with hepatocellular carcinoma or liver metastasis. Typically, MWA ablation margins of 0.5-1.0 cm are desired, which are strongly correlated with treatment efficacy. Our results revealed an average estimated ablation margin inner quartile range of 0.54-1.21 cm with a median value of 0.84 cm. These treatment margins lie within or above the targeted ablative margin, indicating the potential to use EDE for differentiating index tumors and ablated zones during clinical ablations. We also obtained a high correlation between corresponding segmented cross-sectional areas from contrast-enhanced computed tomography, the current clinical gold standard, when compared with EDE strain images, with r2 values of 0.97 and 0.98 for pre- and post-ablation regions.
Collapse
Affiliation(s)
- Robert M Pohlman
- Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA; Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
| | - James L Hinshaw
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Timothy J Ziemlewicz
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Meghan G Lubner
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Shane A Wells
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Fred T Lee
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Marci L Alexander
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Kelly L Wergin
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Tomy Varghese
- Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA; Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| |
Collapse
|
19
|
Borlan R, Focsan M, Maniu D, Astilean S. Interventional NIR Fluorescence Imaging of Cancer: Review on Next Generation of Dye-Loaded Protein-Based Nanoparticles for Real-Time Feedback During Cancer Surgery. Int J Nanomedicine 2021; 16:2147-2171. [PMID: 33746512 PMCID: PMC7966856 DOI: 10.2147/ijn.s295234] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2020] [Accepted: 01/13/2021] [Indexed: 12/13/2022] Open
Abstract
The use of fluorescence imaging technique for visualization, resection and treatment of cancerous tissue, attained plenty of interest once the promise of whole body and deep tissue near-infrared (NIR) imaging emerged. Why is NIR so desired? Contrast agents with optical properties in the NIR spectral range offer an upgrade for the diagnosis and treatment of cancer, by dint of the deep tissue penetration of light in the NIR region of the electromagnetic spectrum, also known as the optical window in biological tissue. Thus, the development of a new generation of NIR emitting and absorbing contrast agents able to overcome the shortcomings of the basic free dye administration is absolutely essential. Several examples of nanoparticles (NPs) have been successfully implemented as carriers for NIR dye molecules to the tumour site owing to their prolonged blood circulation time and enhanced accumulation within the tumour, as well as their increased fluorescence signal relative to free fluorophore emission and active targeting of cancerous cells. Due to their versatile structure, good biocompatibility and capability to efficiently load dyes and bioconjugate with diverse cancer-targeting ligands, the research area of developing protein-based NPs encapsulated or conjugated with NIR dyes is highly promising but still in its infancy. The current review aims to provide an up-to-date overview on the biocompatibility, specific targeting and versatility offered by protein-based NPs loaded with different classes of NIR dyes as next-generation fluorescent agents. Moreover, this study brings to light the newest and most relevant advances involving the state-of-the-art NIR fluorescent agents for the real-time interventional NIR fluorescence imaging of cancer in clinical trials.
Collapse
Affiliation(s)
- Raluca Borlan
- Biomolecular Physics Department, Faculty of Physics, Babeș-Bolyai University, Cluj-Napoca, Cluj, Romania.,Nanobiophotonics and Laser Microspectroscopy Centre, Interdisciplinary Research Institute in Bio-Nano-Sciences, Babeș-Bolyai University, Cluj-Napoca, Cluj, Romania
| | - Monica Focsan
- Nanobiophotonics and Laser Microspectroscopy Centre, Interdisciplinary Research Institute in Bio-Nano-Sciences, Babeș-Bolyai University, Cluj-Napoca, Cluj, Romania
| | - Dana Maniu
- Biomolecular Physics Department, Faculty of Physics, Babeș-Bolyai University, Cluj-Napoca, Cluj, Romania
| | - Simion Astilean
- Biomolecular Physics Department, Faculty of Physics, Babeș-Bolyai University, Cluj-Napoca, Cluj, Romania.,Nanobiophotonics and Laser Microspectroscopy Centre, Interdisciplinary Research Institute in Bio-Nano-Sciences, Babeș-Bolyai University, Cluj-Napoca, Cluj, Romania
| |
Collapse
|
20
|
Saleh M, Virarkar M, Bura V, Valenzuela R, Javadi S, Szklaruk J, Bhosale P. Intrahepatic cholangiocarcinoma: pathogenesis, current staging, and radiological findings. Abdom Radiol (NY) 2020; 45:3662-3680. [PMID: 32417933 DOI: 10.1007/s00261-020-02559-7] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
To this date, it is a major oncological challenge to optimally diagnose, stage, and manage intrahepatic cholangiocarcinoma (ICC). Imaging can not only diagnose and stage ICC, but it can also guide management. Hence, imaging is indispensable in the management of ICC. In this article, we review the pathology, epidemiology, genetics, clinical presentation, staging, pathology, radiology, and treatment of ICC.
Collapse
|
21
|
Puijk RS, Nieuwenhuizen S, van den Bemd BAT, Ruarus AH, Geboers B, Vroomen LGPH, Muglia R, de Jong MC, de Vries JJJ, Scheffer HJ, van den Tol PMP, Meijerink MR. Transcatheter CT Hepatic Arteriography Compared with Conventional CT Fluoroscopy Guidance in Percutaneous Thermal Ablation to Treat Colorectal Liver Metastases: A Single-Center Comparative Analysis of 2 Historical Cohorts. J Vasc Interv Radiol 2020; 31:1772-1783. [PMID: 32981819 DOI: 10.1016/j.jvir.2020.05.011] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Revised: 04/30/2020] [Accepted: 05/04/2020] [Indexed: 02/08/2023] Open
Abstract
PURPOSE To evaluate safety and efficacy of CT hepatic arteriography compared with conventional CT fluoroscopy guidance in percutaneous radiofrequency (RF) and microwave (MW) ablation to treat colorectal liver metastases (CRLM). MATERIALS AND METHODS This single-center comparative, retrospective study analyzed data of 108 patients treated with 156 percutaneous ablation procedures (42 CT fluoroscopy guidance [25 RF ablation, 17 MW ablation]; 114 CT hepatic arteriography guidance [18 RF ablation, 96 MW ablation]) for 260 CRLM between January 2009 and May 2019. Local tumor progression-free survival (LTPFS) was assessed using univariate and multivariate Cox proportional hazard regression analyses. LTPFS and overall survival (OS) were estimated using the Kaplan-Meier method. RESULTS There were no complications related to the transarterial catheter procedure. CT hepatic arteriography proved superior to CT fluoroscopy regarding 2-year LTPFS (18/202 [8.9%] vs 19/58 [32.8%]; P < .001, respectively). CT hepatic arteriography versus CT fluoroscopy (hazard ratio = 0.28; 95% confidence interval, 0.15-0.54; P < .001) and MW ablation versus RF ablation (hazard ratio = 0.52; 95% confidence interval, 0.24-1.12; P = .094) were positive predictors for longer LTPFS. Multivariate analysis revealed that CT hepatic arteriography versus CT fluoroscopy (hazard ratio = 0.41; 95% confidence interval, 0.19-0.90; P = .025) was associated with a significantly superior LTPFS. OS was similar between the 2 cohorts (P = .3). CONCLUSIONS While adding procedure time and marginal patient burden, transcatheter CT hepatic arteriography-guided ablation was associated with increased local disease control and superior LTPFS compared with conventional CT fluoroscopy. CT hepatic arteriography represents a safe and valid alternative to CT fluoroscopy, as it reduces the number of repeat ablations required without adding risk or detrimental effect on survival.
Collapse
Affiliation(s)
- Robbert S Puijk
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers (location VUmc), De Boelelaan 1117, Amsterdam 1081 HV, The Netherlands.
| | - Sanne Nieuwenhuizen
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers (location VUmc), De Boelelaan 1117, Amsterdam 1081 HV, The Netherlands
| | - Bente A T van den Bemd
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers (location VUmc), De Boelelaan 1117, Amsterdam 1081 HV, The Netherlands
| | - Alette H Ruarus
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers (location VUmc), De Boelelaan 1117, Amsterdam 1081 HV, The Netherlands
| | - Bart Geboers
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers (location VUmc), De Boelelaan 1117, Amsterdam 1081 HV, The Netherlands
| | - Laurien G P H Vroomen
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers (location VUmc), De Boelelaan 1117, Amsterdam 1081 HV, The Netherlands
| | - Riccardo Muglia
- Department of Diagnostic and Interventional Radiology, Humanitas Research Hospital, Rozzano, Milan, Italy
| | - Marcus C de Jong
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers (location VUmc), De Boelelaan 1117, Amsterdam 1081 HV, The Netherlands
| | - Jan J J de Vries
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers (location VUmc), De Boelelaan 1117, Amsterdam 1081 HV, The Netherlands
| | - Hester J Scheffer
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers (location VUmc), De Boelelaan 1117, Amsterdam 1081 HV, The Netherlands
| | - Petrousjka M P van den Tol
- Department of Surgical Oncology, Amsterdam University Medical Centers (location VUmc), De Boelelaan 1117, Amsterdam 1081 HV, The Netherlands
| | - Martijn R Meijerink
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers (location VUmc), De Boelelaan 1117, Amsterdam 1081 HV, The Netherlands
| |
Collapse
|
22
|
Rossi SM, Ryan BK, Kelly HM. Evaluation of the activity of a chemo-ablative, thermoresponsive hydrogel in a murine xenograft model of lung cancer. Br J Cancer 2020; 123:369-377. [PMID: 32457364 PMCID: PMC7403591 DOI: 10.1038/s41416-020-0904-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2019] [Revised: 12/30/2019] [Accepted: 02/05/2020] [Indexed: 11/21/2022] Open
Abstract
BACKGROUND Minimally invasive intratumoural administration of thermoresponsive hydrogels, that transition from liquid to gel in response to temperature, has been proposed as a potential treatment modality for solid tumours. The aim of this study was to assess the inherent cytotoxicity of a poloxamer-based thermoresponsive hydrogel in a murine xenograft model of lung cancer. METHODS In vitro viability assessment was carried out in a lung cancer (A549) and non-cancerous (Balb/c 3T3 clone A31) cell line. Following intratumoural administration of saline or the thermoresponsive hydrogel to an A549 xenograft model in female Athymic Nude-Foxn1nu mice (n = 6/group), localisation was confirmed using IVIS imaging. Tumour volume was assessed using callipers measurements over 14 days. Blood serum was analysed for liver and kidney damage and ex vivo tissue samples were histologically assessed. RESULTS The thermoresponsive hydrogel demonstrated a dose-dependent cancer cell-specific toxicity in vitro and was retained in situ for at least 14 days in the xenograft model. Tumour volume increase was statistically significantly lower than saline treated control at day 14 (n = 6, p = 0.0001), with no associated damage of hepatic or renal tissue observed. CONCLUSIONS Presented is a poloxamer-based thermoresponsive hydrogel, suitable for intratumoural administration and retention, which has demonstrated preliminary evidence of local tumour control, with minimal off-site toxicity.
Collapse
Affiliation(s)
- Seóna M Rossi
- School of Pharmacy and Biomolecular Sciences, Royal College of Surgeons in Ireland (RCSI), 123 St. Stephen's Green, Dublin 2, Ireland
- Tissue Engineering Research Group, Department of Anatomy, Royal College of Surgeons in Ireland (RCSI), 123 St Stephen's Green, Dublin 2, Ireland
| | - Benedict K Ryan
- School of Pharmacy and Biomolecular Sciences, Royal College of Surgeons in Ireland (RCSI), 123 St. Stephen's Green, Dublin 2, Ireland
| | - Helena M Kelly
- School of Pharmacy and Biomolecular Sciences, Royal College of Surgeons in Ireland (RCSI), 123 St. Stephen's Green, Dublin 2, Ireland.
- Tissue Engineering Research Group, Department of Anatomy, Royal College of Surgeons in Ireland (RCSI), 123 St Stephen's Green, Dublin 2, Ireland.
| |
Collapse
|
23
|
Safety and efficacy of ultrasound-guided percutaneous coaxial core biopsy of pancreatic lesions: a retrospective study. J Ultrasound 2020; 24:269-277. [PMID: 32705502 DOI: 10.1007/s40477-020-00487-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2020] [Accepted: 05/29/2020] [Indexed: 12/11/2022] Open
Abstract
BACKGROUND AND OBJECTIVE Pancreatic cancer tumors are difficult to access for biopsy. The use of coaxial needles during ultrasound (US)-guided coarse needle biopsy (CNB) may help to improve specimen collection yields and avoid tissue damage. In this retrospective study, the safety, efficacy, and clinical benefits of US-guided percutaneous coaxial CNB of pancreatic masses were evaluated and compared to those of non-coaxial CNB. METHODS A total sample of 220 biopsies performed from August 2015 to August 2019 were analyzed, including 114 performed with a coaxial needle (17-gauge coaxial coarse needle combined with an 18-gauge coarse biopsy needle) and 106 performed with a non-coaxial needle (18-gauge coarse biopsy needle without a coaxial sheath). The coaxial CNB group was stratified by lesion location to further evaluate the applicability of coaxial core needles. The satisfactory specimen rate, diagnostic efficiency, operating time, and complication rate were compared statistically between groups and subgroups. RESULTS Compared to the non-coaxial CNB group, the coaxial CNB group had a greater satisfactory specimen rate (98.3% vs. 92.3%; p = 0.048), a lesser mean operating time (8.9 ± 3.27 min vs. 16.8 ± 5.77 min; p < 0.001), and a lower complication rate (2.6% vs. 9.6%, p =0 .04). A better diagnostic efficiency was obtained for coaxial CNBs in the head of pancreas (98.7%) than in the body or tail of the pancreas (90%, p = 0.047). CONCLUSION For pancreatic masses, coaxial CNB can yield a higher satisfactory sample rate, lower complication rate, and shorter operating time than non-coaxial biopsy. US-guided percutaneous coaxial CNB is a safe and efficient puncture technique for pancreatic lesion diagnosis.
Collapse
|
24
|
Zada MH, Goldberg SN, Nissenbaum Y, Domb AJ, Ben-David E. Injectable Biodegradable Multimodal Mammography Marker. ACS APPLIED BIO MATERIALS 2019; 2:5069-5076. [PMID: 35021505 DOI: 10.1021/acsabm.9b00749] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Introducing temporary markers for imaging studies is an idea, which in the proper clinical settings can be advantageous for patient compliance and in selected cases where a permanent marker is nondesirable. Hence, we developed injectable marker formulation using a biodegradable "pasty polymer" of poly(ricinoleic acid-co-sebacic acid) (PSA:RA) containing iodixanol and iron oxide as contrast agents that can serve as a visual marker for the region suspected to have tumor growth. The goal of this work is to noninvasively evaluate the visibility, shape, and degradation of the injectable PSA:RA formulation using magnetic resonance imaging (MRI), computed tomography (CT), and ultrasound (US). Prescreening of the marker formulation was performed under MRI and CT scanning using agar gel phantom models with poly(l-lactide-co-ε-caprolactone) (PCL:LA) solid inserts (clips) that contained varying combinations of the contrast agents. The contrast agent combination with the PCL:LA clip that had the best visibility in both MRI and CT was selected and additionally tested as in PSA:RA formulation. Further, we evaluated the PSA:RA marker placement in bovine liver and poultry muscles. The PSA:RA formulation is predictable with good MRI, CT, and US visibility and shows no in vivo systemic toxicity symptoms when implanted subcutaneously in mice. Further, the advantage of PSA:RA formulation is its undefined shape and ease of injecting through a small gauge needle, making it possible to reach into the regions of the body.
Collapse
Affiliation(s)
- Moran Haim Zada
- Institute of Drug Research, School of Pharmacy-Faculty of Medicine, The Hebrew University of Jerusalem, Jerusalem 91120, Israel
| | - S Nahum Goldberg
- Department of Radiology, Hadassah Medical Center, Jerusalem 91999, Israel
| | | | - Abraham J Domb
- Institute of Drug Research, School of Pharmacy-Faculty of Medicine, The Hebrew University of Jerusalem, Jerusalem 91120, Israel
| | - Eliel Ben-David
- Department of Radiology, Shaare Zedek Medical Center, Jerusalem 91031, Israel
| |
Collapse
|
25
|
Sundararajan SH, McClure TD, Winokur RS, Kishore SA, Madoff DC. Extrahepatic Clinical Application of Vessel Tracking Software and 3D Roadmapping Tools: Preliminary Experience. J Vasc Interv Radiol 2019; 30:1021-1026. [PMID: 31003843 DOI: 10.1016/j.jvir.2018.11.039] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2018] [Revised: 11/30/2018] [Accepted: 11/30/2018] [Indexed: 12/26/2022] Open
Abstract
This article demonstrates the use of a representative commercially available automated vessel-tracking software originally intended for liver-only application (Vessel Assist Flight Plan for Liver; GE) in 4 patients. Treatment settings included embolization of small bowel hemorrhage source, treatment of renal cell carcinoma, management of symptomatic benign prostate hypertrophy, and detection with subsequent closure of a mesenteric pseudoaneurysm. All patients were treated successfully.
Collapse
Affiliation(s)
- Sri Hari Sundararajan
- Division of Interventional Radiology, Department of Radiology, New York-Presbyterian Hospital/Weill Cornell Medical Center, 525 East 68th Street, P-518, New York, New York 10065
| | - Timothy D McClure
- Division of Interventional Radiology, Department of Radiology, New York-Presbyterian Hospital/Weill Cornell Medical Center, 525 East 68th Street, P-518, New York, New York 10065
| | - Ronald S Winokur
- Division of Interventional Radiology, Department of Radiology, New York-Presbyterian Hospital/Weill Cornell Medical Center, 525 East 68th Street, P-518, New York, New York 10065
| | - Sirish A Kishore
- Division of Interventional Radiology, Department of Radiology, New York-Presbyterian Hospital/Weill Cornell Medical Center, 525 East 68th Street, P-518, New York, New York 10065
| | - David C Madoff
- Division of Interventional Radiology, Department of Radiology, New York-Presbyterian Hospital/Weill Cornell Medical Center, 525 East 68th Street, P-518, New York, New York 10065.
| |
Collapse
|
26
|
Huo J, Aloia TA, Xu Y, Chung TH, Sheu T, Tina Shih YC. Comparative Effectiveness of Computed Tomography- Versus Ultrasound-Guided Percutaneous Radiofrequency Ablation Among Medicare Patients 65 Years of Age or Older With Hepatocellular Carcinoma. VALUE IN HEALTH : THE JOURNAL OF THE INTERNATIONAL SOCIETY FOR PHARMACOECONOMICS AND OUTCOMES RESEARCH 2019; 22:284-292. [PMID: 30832966 PMCID: PMC6402784 DOI: 10.1016/j.jval.2018.10.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2018] [Revised: 10/04/2018] [Accepted: 10/16/2018] [Indexed: 05/17/2023]
Abstract
BACKGROUND For patients with hepatocellular carcinoma (HCC) not eligible for surgical resection, radiofrequency ablation (RFA) is a promising technique that reduces the risk of disease progression. OBJECTIVES To evaluate whether the trend of image guidance for RFA is moving toward the more expensive computed tomography (CT) technology and to determine the clinical benefits of CT guidance over the ultrasound (US) guidance. METHODS A cohort of 463 patients was identified from the Surveillance, Epidemiology, and End Results and Medicare-linked database. The temporal trends in use of image guidance were assessed using the Cochrane-Armitage test. The associations between modality of image guidance and survival, complications, and costs were assessed using the Cox regression model, the logistic regression model, and the generalized linear model, respectively. RESULTS The use of CT-guided RFA increased sharply, from 20.7% in 2002 to 75.9% in 2011. Compared with CT-guided RFA, those who received US-guided RFA had comparable risk of periprocedural and delayed postprocedural complications. Stratified analyses by tumor size also showed no statistically significant difference. In adjusted survival analysis, no statistically significant difference was observed in overall and cancer-specific survival. Nevertheless, the cost of CT-guided RFA ($2847) was higher than that of US-guided RFA ($1862). CONCLUSIONS Despite its rapid adoption over time, CT-guided RFA incurred higher procedural costs than US-guided RFA but did not significantly improve postprocedural complications and survival. Echoing the American Board of Internal Medicine's Choosing Wisely campaign and the American Society of Clinical Oncology's Value of Cancer Care initiative, findings from our study call for critical evaluation of whether CT-guided RFA provides high-value care for patients with HCC.
Collapse
Affiliation(s)
- Jinhai Huo
- Department of Health Services Research, Management and Policy, University of Florida, Gainesville, FL, USA.
| | - Thomas A Aloia
- Department of Surgical Oncology, University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Ying Xu
- Department of Health Services Research, University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Tong Han Chung
- Healthcare Transformation Initiatives, University of Texas Health Science Center-Houston, Houston, TX, USA
| | - Tommy Sheu
- Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Ya-Chen Tina Shih
- Department of Surgical Oncology, University of Texas MD Anderson Cancer Center, Houston, TX, USA
| |
Collapse
|
27
|
Xia D, Chang YB, Manak J, Siddiqui AH, Zhang Z, Chen B, Sidky EY, Pan X. Reduction of Angularly-Varying-Data Truncation in C-Arm CBCT Imaging. SENSING AND IMAGING 2018; 19:14. [PMID: 30319317 PMCID: PMC6181237 DOI: 10.1007/s11220-018-0198-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2017] [Revised: 03/02/2018] [Indexed: 05/07/2023]
Abstract
C-arm cone-beam computed tomography (CBCT) has been used increasingly as an imaging tool for yielding 3D anatomical information about the subjects in surgical and interventional procedures. In the clinical applications, the limited field-of-view (FOV) of C-arm CBCT can lead to significant data truncation, resulting in image artifacts that can obscure low contrast tumor embedded within soft-tissue background, thus limiting the utility of C-arm CBCT. The truncation issue can become serious as most of the surgical and interventional procedures would involve devices and tubes that are placed outside the FOV of C-arm CBCT and thus can engender angularly-varying-data truncation. Existing methods may not be adequately applicable to dealing with the angularly-varying truncation. In this work, we seek to reduce truncation artifacts by tailoring optimization-based reconstruction directly from truncated data, without performing pre-reconstruction data compensation, collected from physical phantoms and human subjects. The reconstruction problem is formulated as a constrained optimization program in which a data-derivative-ℓ2-norm fidelity is included for effectively suppressing image artifacts caused by the angularly-varying-data truncation, and the generic Chambolle-Pock algorithm is tailored to solve the optimization program. The results of the study suggest that an appropriately designed optimization-based reconstruction can be exploited for yielding images with reduced artifacts caused by angularly-varying-data truncation.
Collapse
Affiliation(s)
- Dan Xia
- Department of Radiology, The University of Chicago, Chicago, IL 60637, USA
| | - Yu-Bing Chang
- Canon Medical Research Institute USA, Inc., Vernon Hills, IL 60061, USA
| | - Joe Manak
- Canon Medical Research Institute USA, Inc., Vernon Hills, IL 60061, USA
| | - Adnan H Siddiqui
- University at Buffalo Neurosurgery, Inc., Baffulo, NY 14203, USA
| | - Zheng Zhang
- Department of Radiology, The University of Chicago, Chicago, IL 60637, USA
| | - Buxin Chen
- Department of Radiology, The University of Chicago, Chicago, IL 60637, USA
| | - Emil Y Sidky
- Department of Radiology, The University of Chicago, Chicago, IL 60637, USA
| | - Xiaochuan Pan
- Department of Radiology, The University of Chicago, Chicago, IL 60637, USA
| |
Collapse
|
28
|
Woodard LE, Dennis CL, Borchers JA, Attaluri A, Velarde E, Dawidczyk C, Searson PC, Pomper MG, Ivkov R. Nanoparticle architecture preserves magnetic properties during coating to enable robust multi-modal functionality. Sci Rep 2018; 8:12706. [PMID: 30139940 PMCID: PMC6107675 DOI: 10.1038/s41598-018-29711-0] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2018] [Accepted: 07/17/2018] [Indexed: 11/09/2022] Open
Abstract
Magnetic iron oxide nanoparticles (MIONs) have established a niche as a nanomedicine platform for diagnosis and therapy, but they present a challenging surface for ligand functionalization which limits their applications. On the other hand, coating MIONs with another material such as gold to enhance these attachments introduces other complications. Incomplete coating may expose portions of the iron oxide core, or the coating process may alter their magnetic properties. We describe synthesis and characterization of iron oxide/silica/gold core-shell nanoparticles to elucidate the effects of a silica-gold coating process and its impact on the resulting performance. In particular, small angle neutron scattering reveals silica intercalates between iron oxide crystallites that form the dense core, likely preserving the magnetic properties while enabling formation of a continuous gold shell. The synthesized silica-gold-coated MIONs demonstrate magnetic heating properties consistent with the original iron oxide core, with added x-ray contrast for imaging and laser heating.
Collapse
Affiliation(s)
- Lauren E Woodard
- Institute for NanoBioTechnology, Johns Hopkins University, Baltimore, MD, 21218, USA
| | - Cindi L Dennis
- Material Measurement Laboratory, NIST, Gaithersburg, MD, 20899-8550, USA
| | - Julie A Borchers
- NIST Center for Neutron Research, NIST, Gaithersburg, MD, 20899-6102, USA
| | - Anilchandra Attaluri
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD, 21231, USA
- Department of Mechanical Engineering, School of Science, Engineering, and Technology, Pennsylvania State University, Harrisburg,Middletown, PA, 17057, USA
| | - Esteban Velarde
- Department of Oncology, Johns Hopkins University School of Medicine, Baltimore, MD, 21231, USA
| | - Charlene Dawidczyk
- Institute for NanoBioTechnology, Johns Hopkins University, Baltimore, MD, 21218, USA
| | - Peter C Searson
- Institute for NanoBioTechnology, Johns Hopkins University, Baltimore, MD, 21218, USA
- Department of Oncology, Johns Hopkins University School of Medicine, Baltimore, MD, 21231, USA
- Department of Materials Science and Engineering, Johns Hopkins University, Baltimore, MD, 21218, USA
| | - Martin G Pomper
- Institute for NanoBioTechnology, Johns Hopkins University, Baltimore, MD, 21218, USA
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD, 21231, USA
- Department of Oncology, Johns Hopkins University School of Medicine, Baltimore, MD, 21231, USA
- Department of Materials Science and Engineering, Johns Hopkins University, Baltimore, MD, 21218, USA
- Division of Cancer Imaging Research, Russell H. Morgan Department of Radiology and Radiological Sciences, Johns Hopkins University School of Medicine, Baltimore, MD, 21231, USA
| | - Robert Ivkov
- Institute for NanoBioTechnology, Johns Hopkins University, Baltimore, MD, 21218, USA.
- NIST Center for Neutron Research, NIST, Gaithersburg, MD, 20899-6102, USA.
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, 21218, USA.
| |
Collapse
|
29
|
Puijk RS, Ruarus AH, Scheffer HJ, Vroomen LGPH, van Tilborg AAJM, de Vries JJJ, Berger FH, van den Tol PMP, Meijerink MR. Percutaneous Liver Tumour Ablation: Image Guidance, Endpoint Assessment, and Quality Control. Can Assoc Radiol J 2018; 69:51-62. [PMID: 29458955 DOI: 10.1016/j.carj.2017.11.001] [Citation(s) in RCA: 53] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2017] [Revised: 11/01/2017] [Accepted: 11/07/2017] [Indexed: 02/06/2023] Open
Abstract
Liver tumour ablation nowadays represents a routine treatment option for patients with primary and secondary liver tumours. Radiofrequency ablation and microwave ablation are the most widely adopted methods, although novel techniques, such as irreversible electroporation, are quickly working their way up. The percutaneous approach is rapidly gaining popularity because of its minimally invasive character, low complication rate, good efficacy rate, and repeatability. However, matched to partial hepatectomy and open ablations, the issue of ablation site recurrences remains unresolved and necessitates further improvement. For percutaneous liver tumour ablation, several real-time imaging modalities are available to improve tumour visibility, detect surrounding critical structures, guide applicators, monitor treatment effect, and, if necessary, adapt or repeat energy delivery. Known predictors for success are tumour size, location, lesion conspicuity, tumour-free margin, and operator experience. The implementation of reliable endpoints to assess treatment efficacy allows for completion-procedures, either within the same session or within a couple of weeks after the procedure. Although the effect on overall survival may be trivial, (local) progression-free survival will indisputably improve with the implementation of reliable endpoints. This article reviews the available needle navigation techniques, evaluates potential treatment endpoints, and proposes an algorithm for quality control after the procedure.
Collapse
Affiliation(s)
- Robbert S Puijk
- Department of Radiology and Nuclear Medicine, VU University Medical Center, Amsterdam, the Netherlands.
| | - Alette H Ruarus
- Department of Radiology and Nuclear Medicine, VU University Medical Center, Amsterdam, the Netherlands
| | - Hester J Scheffer
- Department of Radiology and Nuclear Medicine, VU University Medical Center, Amsterdam, the Netherlands
| | - Laurien G P H Vroomen
- Department of Radiology and Nuclear Medicine, VU University Medical Center, Amsterdam, the Netherlands
| | - Aukje A J M van Tilborg
- Department of Radiology and Nuclear Medicine, VU University Medical Center, Amsterdam, the Netherlands
| | - Jan J J de Vries
- Department of Radiology and Nuclear Medicine, VU University Medical Center, Amsterdam, the Netherlands
| | - Ferco H Berger
- Department of Medical Imaging, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
| | | | - Martijn R Meijerink
- Department of Radiology and Nuclear Medicine, VU University Medical Center, Amsterdam, the Netherlands
| |
Collapse
|
30
|
Abstract
Multifunctional nanoparticles with superior imaging properties and therapeutic effects have been extensively developed for the nanomedicine. However, tumor-intrinsic barriers and tumor heterogeneity have resulted in low in vivo therapeutic efficacy. The poor in vivo targeting efficiency in passive and active targeting of nanotherapeutics along with the toxicity of nanoparticles has been a major problem in nanomedicine. Recently, image-guided nanomedicine, which can deliver nanoparticles locally using non-invasive imaging and interventional oncology techniques, has been paid attention as a new opportunity of nanomedicine. This short review will discuss the existing challenges in nanomedicine and describe the prospects for future image-guided nanomedicine.
Collapse
Affiliation(s)
- Dong-Hyun Kim
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL 60611, USA
- Robert H. Lurie Comprehensive Cancer Center, Chicago, IL 60611, USA
| |
Collapse
|
31
|
Miner RC. Image-Guided Neurosurgery. J Med Imaging Radiat Sci 2017; 48:328-335. [PMID: 31047466 DOI: 10.1016/j.jmir.2017.06.005] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2017] [Accepted: 06/27/2017] [Indexed: 01/21/2023]
Abstract
Image-guided surgery provides more precise targeting, is less invasive, and has improved outcomes when compared with conventional surgical approaches. Imaging is used to plan, monitor progress, and assess results. Because no one modality offers real-time physiological and anatomical information, a wide range of imaging modalities are used at each phase of the surgery. This article will discuss how various modalities are used in image-guided neurosurgery for common brain pathologies.
Collapse
Affiliation(s)
- Robert C Miner
- Carleton University, Ottawa, Ontario, Canada; Ottawa Heart Institute, Ottawa, Ontario, Canada.
| |
Collapse
|
32
|
Cornelis FH, Marin F, Labrèze C, Pinsolle V, Le Bras Y, Midy D, Grenier N. Percutaneous cryoablation of symptomatic venous malformations as a second-line therapeutic option: a five-year single institution experience. Eur Radiol 2017; 27:5015-5023. [PMID: 28677056 DOI: 10.1007/s00330-017-4892-y] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2017] [Revised: 04/17/2017] [Accepted: 05/11/2017] [Indexed: 01/20/2023]
Abstract
PURPOSE To report the mid-term outcomes of percutaneous cryoablation (PCA) performed as second-line therapeutic option of venous malformations (VM). MATERIAL AND METHODS From 2011 to 2015, PCA was offered in 24 patients (mean age: 31 years, range: 12-64) as second-line treatment for recurrence of symptoms after sclerotherapy and when resection was not possible (due to lesion location or previous failure) or refused by the patient. Adverse effects were recorded, disease-free survival (DFS) and local tissue control (LTC) rates were calculated based on symptoms and volume evolution. RESULTS Mean follow-up was 18.7 months (6-48). Nine (37.5%, 9/24) adverse effects occurred and three (12.5%, 3/24) were severe. Mean pain assessed by visual analog scale (VAS) was 41.7 mm (0-80) before treatment and 20.3 mm (0-80) (p=0.01) after. Mean volume decreased significantly after treatment from 22.4 cm3 (0.9-146) to 8.35 cm3 (0-81.3) (p<0.001). Pain recurred in nine patients and size of one lesion increased. The DFS and LTC rates were 54% [95%CI: 22.94-77.27] and 93.33% [61.26-99.03] at 24 months, respectively. Only VM volume >10 cm3 was associated with a higher risk of local recurrence (p=0.05). CONCLUSION PCA as second-line treatment appears to be safe and effective for local control of VM according to mid-term results. KEY POINTS • Percutaneous cryoablation of venous malformations appeared well tolerated. • Size of venous malformations decreased significantly after percutaneous cryoablation (p<0.001). • Pain decreased significantly after percutaneous cryoablation of venous malformations (p=0.01).
Collapse
Affiliation(s)
- F H Cornelis
- Department of Radiology, Pellegrin Hospital, Place Amélie Raba Léon, 33076, Bordeaux, France. .,Department of Radiology, Tenon Hospital, APHP, 4 rue de la Chine, 75020, Paris, France.
| | - F Marin
- Department of Radiology, Pellegrin Hospital, Place Amélie Raba Léon, 33076, Bordeaux, France
| | - C Labrèze
- Department of Pediatric Dermatology, Pellegrin Hospital, Place Amélie Raba Léon, 33076, Bordeaux, France
| | - V Pinsolle
- Department of Aesthetic Surgery, Pellegrin Hospital, Place Amélie Raba Léon, 33076, Bordeaux, France
| | - Y Le Bras
- Department of Radiology, Pellegrin Hospital, Place Amélie Raba Léon, 33076, Bordeaux, France
| | - D Midy
- Department of Vascular Surgery, Pellegrin Hospital, Place Amélie Raba Léon, 33076, Bordeaux, France
| | - N Grenier
- Department of Radiology, Pellegrin Hospital, Place Amélie Raba Léon, 33076, Bordeaux, France
| |
Collapse
|
33
|
Cornelis FH, Durack JC, Kimm SY, Wimmer T, Coleman JA, Solomon SB, Srimathveeravalli G. A Comparative Study of Ablation Boundary Sharpness After Percutaneous Radiofrequency, Cryo-, Microwave, and Irreversible Electroporation Ablation in Normal Swine Liver and Kidneys. Cardiovasc Intervent Radiol 2017; 40:1600-1608. [PMID: 28516273 DOI: 10.1007/s00270-017-1692-3] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2017] [Accepted: 05/03/2017] [Indexed: 02/08/2023]
Abstract
PURPOSE To compare ablation boundary sharpness after percutaneous radiofrequency ablation (RFA), cryoablation (CA), microwave ablation (MWA) and irreversible electroporation (IRE) ablation in normal swine liver and kidney. MATERIALS AND METHODS Percutaneous CT-guided RFA (n = 5), CA (n = 5), MWA (n = 5) and IRE (n = 5) were performed in the liver and kidney of four Yorkshire pigs. Parameters were chosen to produce ablations 2-3 cm in diameter with a single ablation probe. Contrast-enhanced CT imaging was performed 24 h after ablation, and animals were killed. Treated organs were removed and processed for histologic analysis with hematoxylin and eosin, and terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL). Three readers independently analyzed CT, H&E and TUNEL stained images of the ablation boundary to delineate regions of (1) viable cells, (2) complete necrosis or (3) mixture of viable and necrotic cells which was defined as the transition zone (TZ). The width of TZ was compared across the techniques and organs. RESULTS Ablations appeared as non-contrast-enhancing regions on CT with sharp transition to enhancing normal tissue. On TUNEL stained slides, the mean width (μm) of the TZ after MWA was 319 ± 157 in liver and 267 ± 95 in kidney, which was significantly lower than RFA (811 ± 477 and 938 ± 429); CA (452 ± 222 and 700 ± 563); and IRE (1319 ± 682 and 1570 ± 962) (all p < 0.01). No significant differences were observed between the organs. CONCLUSION Under similar conditions, the width of the TZ at the ablation boundary varies significantly between different ablation techniques.
Collapse
Affiliation(s)
- Francois H Cornelis
- Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Jeremy C Durack
- Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Simon Y Kimm
- Department of Urology, Palo Alto Medical Foundation, Palo Alto, CA, USA
| | | | - Jonathan A Coleman
- Division of Urology, Department of Surgery, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Stephen B Solomon
- Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Govindarajan Srimathveeravalli
- Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA. .,Weill Cornell Medical College, New York, NY, USA.
| |
Collapse
|
34
|
Lin MX, Kuang M, Xu M, Zhuang BW, Tian WS, Ye JY, Xie XH, Xie XY. Ultrasound and Contrast-Enhanced Ultrasound for Evaluation of Irreversible Electroporation Ablation: In Vivo Proof of Concept in Normal Porcine Liver. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:2639-2649. [PMID: 27546157 DOI: 10.1016/j.ultrasmedbio.2016.07.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2016] [Revised: 06/27/2016] [Accepted: 07/06/2016] [Indexed: 06/06/2023]
Abstract
The objective of this study was to describe the performance of ultrasound (US) and contrast-enhanced ultrasound (CEUS) within 2 h after irreversible electroporation (IRE) ablation of porcine liver. Six IRE ablations were performed on porcine liver in vivo; ultrasound assessments were performed within 2 h after IRE ablation. On US images, the ablation zone appeared as a hypo-echoic area within 10 min after the ablation, and then the echo of the ablation zone gradually increased. On CEUS images, the ablation zone appeared as a non-enhanced area within 10 min after ablation and then was gradually centripetally filled by microbubbles. A hyper-echoic rim on US images and a hyper-enhanced rim on CEUS images appeared in the periphery of the ablation zone 60 min after the ablation. Characteristic and dynamic ultrasound images of the IRE ablation zone were obtained within 2 h after IRE ablation of in vivo porcine liver.
Collapse
Affiliation(s)
- Man-Xia Lin
- Department of Medical Ultrasonics, First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, Guangzhou, China
| | - Ming Kuang
- Department of Medical Ultrasonics, First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, Guangzhou, China; Department of Hepatobiliary Surgery, First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, China
| | - Ming Xu
- Department of Medical Ultrasonics, First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, Guangzhou, China
| | - Bo-Wen Zhuang
- Department of Medical Ultrasonics, First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, Guangzhou, China
| | - Wen-Shuo Tian
- Department of Medical Ultrasonics, First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, Guangzhou, China
| | - Jie-Yi Ye
- Department of Medical Ultrasonics, First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, Guangzhou, China
| | - Xiao-Hua Xie
- Department of Medical Ultrasonics, First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, Guangzhou, China
| | - Xiao-Yan Xie
- Department of Medical Ultrasonics, First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, Guangzhou, China.
| |
Collapse
|
35
|
Xia D, Langan DA, Solomon SB, Zhang Z, Chen B, Lai H, Sidky EY, Pan X. Optimization-based image reconstruction with artifact reduction in C-arm CBCT. Phys Med Biol 2016; 61:7300-7333. [PMID: 27694700 PMCID: PMC5109550 DOI: 10.1088/0031-9155/61/20/7300] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
We investigate an optimization-based reconstruction, with an emphasis on image-artifact reduction, from data collected in C-arm cone-beam computed tomography (CBCT) employed in image-guided interventional procedures. In the study, an image to be reconstructed is formulated as a solution to a convex optimization program in which a weighted data divergence is minimized subject to a constraint on the image total variation (TV); a data-derivative fidelity is introduced in the program specifically for effectively suppressing dominant, low-frequency data artifact caused by, e.g. data truncation; and the Chambolle-Pock (CP) algorithm is tailored to reconstruct an image through solving the program. Like any other reconstructions, the optimization-based reconstruction considered depends upon numerous parameters. We elucidate the parameters, illustrate their determination, and demonstrate their impact on the reconstruction. The optimization-based reconstruction, when applied to data collected from swine and patient subjects, yields images with visibly reduced artifacts in contrast to the reference reconstruction, and it also appears to exhibit a high degree of robustness against distinctively different anatomies of imaged subjects and scanning conditions of clinical significance. Knowledge and insights gained in the study may be exploited for aiding in the design of practical reconstructions of truly clinical-application utility.
Collapse
Affiliation(s)
- Dan Xia
- Department of Radiology, The University of Chicago, Chicago, IL, USA
| | | | | | | | | | | | | | | |
Collapse
|
36
|
Neumann W, Lietzmann F, Schad LR, Zöllner FG. Design of a multimodal ( 1H/ 23Na MR/CT) anthropomorphic thorax phantom. Z Med Phys 2016; 27:124-131. [PMID: 27596568 DOI: 10.1016/j.zemedi.2016.07.004] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2016] [Revised: 07/04/2016] [Accepted: 07/26/2016] [Indexed: 01/07/2023]
Abstract
OBJECTIVES This work proposes a modular, anthropomorphic MR and CT thorax phantom that enables the comparison of experimental studies for quantitative evaluation of deformable, multimodal image registration algorithms and realistic multi-nuclear MR imaging techniques. METHODS A human thorax phantom was developed with insertable modules representing lung, liver, ribs and additional tracking spheres. The quality of human tissue mimicking characteristics was evaluated for 1H and 23Na MR as well as CT imaging. The position of landmarks in the lung lobes was tracked during CT image acquisition at several positions during breathing cycles. 1H MR measurements of the liver were repeated after seven months to determine long term stability. RESULTS The modules possess HU, T1 and T2 values comparable to human tissues (lung module: -756±148HU, artificial ribs: 218±56HU (low CaCO3 concentration) and 339±121 (high CaCO3 concentration), liver module: T1=790±28ms, T2=65±1ms). Motion analysis showed that the landmarks in the lung lobes follow a 3D trajectory similar to human breathing motion. The tracking spheres are well detectable in both CT and MRI. The parameters of the tracking spheres can be adjusted in the following ranges to result in a distinct signal: HU values from 150 to 900HU, T1 relaxation time from 550ms to 2000ms, T2 relaxation time from 40ms to 200ms. CONCLUSION The presented anthropomorphic multimodal thorax phantom fulfills the demands of a simple, inexpensive system with interchangeable components. In future, the modular design allows for complementing the present set up with additional modules focusing on specific research targets such as perfusion studies, 23Na MR quantification experiments and an increasing level of complexity for motion studies.
Collapse
Affiliation(s)
- Wiebke Neumann
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Germany.
| | - Florian Lietzmann
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Germany
| | - Lothar R Schad
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Germany
| | - Frank G Zöllner
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Germany
| |
Collapse
|
37
|
Ahmed Y, Novak RD, Nakamoto D, Azar N. Is Ultrasound Fusion a Reasonable Replacement for Computed Tomography in Guiding Abdominal Interventions? JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2016; 35:1131-1141. [PMID: 27091917 DOI: 10.7863/ultra.15.06007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/03/2015] [Accepted: 08/31/2015] [Indexed: 06/05/2023]
Abstract
OBJECTIVES To compare the diagnostic yield, complication rate, and procedure length of ultrasound fusion-guided liver biopsy to the diagnostic yield, complication rate, and procedure length of computed tomography (CT)-guided liver biopsy; to measure the average ionizing radiation dose that patients are exposed to during a typical CT-guided liver biopsy procedure; and to present relevant and interesting cases of ultrasound fusion-guided abdominal interventions to describe the efficacious use of the technology. METHODS A retrospective analysis of 63 patients who had image-guided liver biopsies performed at our institution was completed. Patient records were divided into 2 groups according to the type of image guidance used during the procedure (ultrasound fusion versus CT), and data were compared by the χ(2) test, Student t test, and Mann-Whitney U test. RESULTS The diagnostic yields and complication rates were not statistically significantly different between the modalities. The average procedure durations were significantly different: ultrasound fusion-guided biopsy, 31.63 minutes; compared to CT-guided biopsy, 61.67 minutes (P = .003). CONCLUSIONS Diagnostic yields and complication rates were comparable for ultrasound fusion and CT. However, the average procedure duration for an ultrasound fusion-guided liver biopsy was approximately half that of CT-guided liver biopsy, likely increasing both cost-effectiveness and patient satisfaction.
Collapse
Affiliation(s)
- Yasmine Ahmed
- University Hospitals, Case Medical Center, Cleveland, Ohio USA
| | - Ronald D Novak
- University Hospitals, Case Medical Center, Cleveland, Ohio USACase Western Reserve University School of Medicine, Cleveland, Ohio USA
| | - Dean Nakamoto
- University Hospitals, Case Medical Center, Cleveland, Ohio USA
| | - Nami Azar
- University Hospitals, Case Medical Center, Cleveland, Ohio USA
| |
Collapse
|
38
|
Attaluri A, Seshadri M, Mirpour S, Wabler M, Marinho T, Furqan M, Zhou H, De Paoli S, Gruettner C, Gilson W, DeWeese T, Garcia M, Ivkov R, Liapi E. Image-guided thermal therapy with a dual-contrast magnetic nanoparticle formulation: A feasibility study. Int J Hyperthermia 2016; 32:543-57. [PMID: 27151045 DOI: 10.3109/02656736.2016.1159737] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
PURPOSE/OBJECTIVE The aim of this study was to develop and investigate the properties of a magnetic iron oxide nanoparticle-ethiodised oil formulation for image-guided thermal therapy of liver cancer. MATERIALS AND METHODS The formulation comprises bionised nano-ferrite (BNF) nanoparticles suspended in ethiodised oil, emulsified with polysorbate 20 (BNF-lip). Nanoparticle size was measured via photon correlation spectroscopy and transmission electron microscopy. In vivo thermal therapy capability was tested in two groups of male Foxn1(nu) mice bearing subcutaneous HepG2 xenograft tumours. Group I (n = 12) was used to screen conditions for group II (n = 48). In group II, mice received one of BNF-lip (n = 18), BNF alone (n = 16), or PBS (n = 14), followed by alternating magnetic field (AMF) hyperthermia, with either varied duration (15 or 20 min) or amplitude (0, 16, 20, or 24 kA/m). Image-guided fluoroscopic intra-arterial injection of BNF-lip was tested in New Zealand white rabbits (n = 10), bearing liver VX2 tumours. The animals were subsequently imaged with CT and 3 T MRI, up to 7 days post-injection. The tumours were histopathologically evaluated for distribution of BNF-lip. RESULTS The BNF showed larger aggregate diameters when suspended in BNF-lip, compared to clear solution. The BNF-lip formulation produced maximum tumour temperatures with AMF >20 kA/m and showed positive X-ray visibility and substantial shortening of T1 and T2 relaxation time, with sustained intratumoural retention up to 7 days post-injection. On pathology, intratumoural BNF-lip distribution correlated well with CT imaging of intratumoural BNF-lip distribution. CONCLUSION The BNF-lip formulation has favourable thermal and dual imaging capabilities for image-guided thermal therapy of liver cancer, suggesting further exploration for clinical applications.
Collapse
Affiliation(s)
- Anilchandra Attaluri
- a Department of Radiation Oncology and Molecular Radiation Sciences , Johns Hopkins University School of Medicine , Baltimore , Maryland
| | - Madhav Seshadri
- a Department of Radiation Oncology and Molecular Radiation Sciences , Johns Hopkins University School of Medicine , Baltimore , Maryland
| | - Sahar Mirpour
- b Department of Radiology and Radiological Sciences , Johns Hopkins Hospital , Baltimore , Maryland
| | - Michele Wabler
- a Department of Radiation Oncology and Molecular Radiation Sciences , Johns Hopkins University School of Medicine , Baltimore , Maryland
| | - Thomas Marinho
- a Department of Radiation Oncology and Molecular Radiation Sciences , Johns Hopkins University School of Medicine , Baltimore , Maryland
| | - Muhammad Furqan
- a Department of Radiation Oncology and Molecular Radiation Sciences , Johns Hopkins University School of Medicine , Baltimore , Maryland
| | - Haoming Zhou
- a Department of Radiation Oncology and Molecular Radiation Sciences , Johns Hopkins University School of Medicine , Baltimore , Maryland
| | - Silvia De Paoli
- c Center for Biological Evaluation and Research , Food and Drug Administration , Bethesda , Maryland , USA
| | | | - Wesley Gilson
- e Siemens Healthcare Solutions, Inc. , Baltimore , Maryland , USA
| | - Theodore DeWeese
- a Department of Radiation Oncology and Molecular Radiation Sciences , Johns Hopkins University School of Medicine , Baltimore , Maryland
| | - Monica Garcia
- a Department of Radiation Oncology and Molecular Radiation Sciences , Johns Hopkins University School of Medicine , Baltimore , Maryland ;,f Department of Genetics and Morphology , Institute of Biological Sciences, University of Brasilia , Brazil
| | - Robert Ivkov
- a Department of Radiation Oncology and Molecular Radiation Sciences , Johns Hopkins University School of Medicine , Baltimore , Maryland ;,g Department of Oncology , Johns Hopkins University School of Medicine , Baltimore , Maryland ;,h Institute for NanoBioTechnology, Johns Hopkins University , Baltimore , Maryland ;,i Department of Materials Science and Engineering , Johns Hopkins University , Baltimore , Maryland , USA
| | - Eleni Liapi
- b Department of Radiology and Radiological Sciences , Johns Hopkins Hospital , Baltimore , Maryland
| |
Collapse
|
39
|
Abstract
Although molecular imaging has had a dramatic impact on diagnostic imaging, it has only recently begun to be integrated into interventional procedures. Its significant impact is attributed to its ability to provide noninvasive, physiologic information that supplements conventional morphologic imaging. The four major interventional opportunities for molecular imaging are, first, to provide guidance to localize a target; second, to provide tissue analysis to confirm that the target has been reached; third, to provide in-room, posttherapy assessment; and fourth, to deliver targeted therapeutics. With improved understanding and application of(18)F-FDG, as well as the addition of new molecular probes beyond(18)F-FDG, the future holds significant promise for the expansion of molecular imaging into the realm of interventional procedures.
Collapse
Affiliation(s)
- Stephen B Solomon
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York; and
| | - Francois Cornelis
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York; and Department of Radiology, Pellegrin Hospital, Bordeaux, France
| |
Collapse
|
40
|
Mar WA, Shon AM, Lu Y, Yu JH, Berggruen SM, Guzman G, Ray CE, Miller F. Imaging spectrum of cholangiocarcinoma: role in diagnosis, staging, and posttreatment evaluation. Abdom Radiol (NY) 2016; 41:553-67. [PMID: 26847022 DOI: 10.1007/s00261-015-0583-9] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Cholangiocarcinoma, a tumor of biliary epithelium, is increasing in incidence. The imaging appearance, behavior, and treatment of cholangiocarcinoma differ according to its location and morphology. Cholangiocarcinoma is usually classified as intrahepatic, perihilar, or distal. The three morphologies are mass-forming, periductal sclerosing, and intraductal growing. As surgical resection is the only cure, prompt diagnosis and accurate staging is crucial. In staging, vascular involvement, longitudinal spread, and lymphadenopathy are important to assess. The role of liver transplantation for unresectable peripheral cholangiocarcinoma will be discussed. Locoregional therapy can extend survival for those with unresectable intrahepatic tumors. The main risk factors predisposing to cholangiocarcinoma are parasitic infections, primary sclerosing cholangitis, choledochal cysts, and viral hepatitis. Several inflammatory conditions can mimic cholangiocarcinoma, including IgG4 disease, sclerosing cholangitis, Mirizzi's syndrome, and recurrent pyogenic cholangitis. The role of PET in diagnosis and staging will also be discussed. Radiologists play a crucial role in diagnosis, staging, and treatment of this disease.
Collapse
Affiliation(s)
- Winnie A Mar
- Department of Radiology, University of Illinois at Chicago, 1740 W Taylor St Rm 2483, MC 931, Chicago, IL, 60612, USA.
| | - Andrew M Shon
- Department of Radiology, University of Illinois at Chicago, 1740 W Taylor St Rm 2483, MC 931, Chicago, IL, 60612, USA
| | - Yang Lu
- Department of Radiology, University of Illinois at Chicago, 1740 W Taylor St Rm 2483, MC 931, Chicago, IL, 60612, USA
| | - Jonathan H Yu
- Department of Radiology, University of Illinois at Chicago, 1740 W Taylor St Rm 2483, MC 931, Chicago, IL, 60612, USA
| | - Senta M Berggruen
- Department of Radiology, Northwestern University, NMH/Arkes Family Pavilion Suite 800, 676 N Saint Clair, Chicago, IL, 60611, USA
| | - Grace Guzman
- Department of Pathology, University of Illinois at Chicago, 840 S. Wood St., Suite 130 CSN, MC 847, Chicago, IL, 60612, USA
| | - Charles E Ray
- Department of Radiology, University of Illinois at Chicago, 1740 W Taylor St Rm 2483, MC 931, Chicago, IL, 60612, USA
| | - Frank Miller
- Department of Radiology, Northwestern University, NMH/Arkes Family Pavilion Suite 800, 676 N Saint Clair, Chicago, IL, 60611, USA
| |
Collapse
|
41
|
Chen CS, Zhao Q, Qian S, Li HL, Guo CY, Zhang W, Yan ZP, Liu R, Wang JH. Ultrasound-guided RNA interference targeting HIF-1 alpha improves the effects of transarterial chemoembolization in rat liver tumors. Onco Targets Ther 2015; 8:3539-48. [PMID: 26664137 PMCID: PMC4669929 DOI: 10.2147/ott.s94800] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Aim To investigate whether ultrasound-guided RNA interference (RNAi) targeting hypoxia-inducible factor-1alpha (HIF-1α) can enhance the efficacy of transarterial chemoembolization (TACE) in treating hepatocellular carcinoma. Materials and methods Rats with orthotopic hepatocellular carcinoma were randomized to four groups and treated as follows: 1) control; 2) siHIF-1α; 3) TACE; 4) siHIF-1α+TACE. Lentivirus (4×108 transfection units) with or without small interfering RNA (siRNA) expression in 0.6 mL transduction reagent was injected into tumors using a standard 1 mL syringe under ultrasonic guidance. In the siHIF-1α+TACE and siHIF-1α groups, rats received siRNA-expressing lentivirus; the rats in the TACE and control groups received lentivirus without siRNA. TACE was performed by placing a microcatheter into the gastroduodenal artery. Results The median survival time, body weight, and tumor volume of the siHIF-1α+TACE group were better than those of the TACE, siHIF-1α, and control groups. A comparative analysis of the different treatment groups demonstrated that HIF-1α RNAi could downregulate the levels of HIF-1α and VEGF, inhibit tumor angiogenesis, and lessen metastases; all of these effects were enhanced by TACE. Conclusion HIF-1α RNAi, which was administered in vivo in liver tumors under ultrasound guidance, improved the efficacy of TACE in treating hepatocellular carcinoma in an animal model.
Collapse
Affiliation(s)
- Cheng-Shi Chen
- Department of Interventional Radiology, Zhongshan Hospital, Fudan University, Shanghai, People's Republic of China ; Department of Radiology, Henan Cancer Hospital, Zhengzhou University, Zhengzhou, People's Republic of China
| | - Qing Zhao
- Department of Interventional Radiology, Zhongshan Hospital, Fudan University, Shanghai, People's Republic of China
| | - Sheng Qian
- Department of Interventional Radiology, Zhongshan Hospital, Fudan University, Shanghai, People's Republic of China
| | - Hai-Liang Li
- Department of Radiology, Henan Cancer Hospital, Zhengzhou University, Zhengzhou, People's Republic of China
| | - Chen-Yang Guo
- Department of Radiology, Henan Cancer Hospital, Zhengzhou University, Zhengzhou, People's Republic of China
| | - Wei Zhang
- Department of Interventional Radiology, Zhongshan Hospital, Fudan University, Shanghai, People's Republic of China
| | - Zhi-Ping Yan
- Department of Interventional Radiology, Zhongshan Hospital, Fudan University, Shanghai, People's Republic of China
| | - Rong Liu
- Department of Interventional Radiology, Zhongshan Hospital, Fudan University, Shanghai, People's Republic of China
| | - Jian-Hua Wang
- Department of Interventional Radiology, Zhongshan Hospital, Fudan University, Shanghai, People's Republic of China
| |
Collapse
|
42
|
Cone Beam Computed Tomography (CBCT) in the Field of Interventional Oncology of the Liver. Cardiovasc Intervent Radiol 2015; 39:8-20. [DOI: 10.1007/s00270-015-1180-6] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/01/2015] [Accepted: 06/27/2015] [Indexed: 12/21/2022]
|
43
|
Abdel-Rehim M, Ronot M, Sibert A, Vilgrain V. Assessment of liver ablation using cone beam computed tomography. World J Gastroenterol 2015; 21:517-524. [PMID: 25593467 PMCID: PMC4292283 DOI: 10.3748/wjg.v21.i2.517] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/30/2014] [Revised: 08/04/2014] [Accepted: 10/15/2014] [Indexed: 02/06/2023] Open
Abstract
AIM: To investigate the feasibility and accuracy of cone beam computed tomography (CBCT) in assessing the ablation zone after liver tumor ablation.
METHODS: Twenty-three patients (17 men and 6 women, range: 45-85 years old, mean age 65 years) with malignant liver tumors underwent ultrasound-guided percutaneous tumor ablation [radiofrequency (n = 14), microwave (n = 9)] followed by intravenous contrast-enhanced CBCT. Baseline multidetector computed tomography (MDCT) and peri-procedural CBCT images were compared. CBCT image quality was assessed as poor, good, or excellent. Image fusion was performed to assess tumor coverage, and quality of fusion was rated as bad, good, or excellent. Ablation zone volumes on peri-procedural CBCT and post-procedural MDCT were compared using the non-parametric paired Wilcoxon t-test.
RESULTS: Rate of primary ablation effectiveness was 100%. There were no complications related to ablation. Local tumor recurrence and new liver tumors were found 3 mo after initial treatment in one patient (4%). The ablation zone was identified in 21/23 (91.3%) patients on CBCT. The fusion of baseline MDCT and peri-procedural CBCT images was feasible in all patients and showed satisfactory tumor coverage (at least 5-mm margin). CBCT image quality was poor, good, and excellent in 2 (9%), 8 (35%), and 13 (56%), patients respectively. Registration quality between peri-procedural CBCT and post-procedural MDCT images was good to excellent in 17/23 (74%) patients. The median ablation volume on peri-procedural CBCT and post-procedural MDCT was 30 cm3 (range: 4-95 cm3) and 30 cm3 (range: 4-124 cm3), respectively (P-value > 0.2). There was a good correlation (r = 0.79) between the volumes of the two techniques.
CONCLUSION: Contrast-enhanced CBCT after tumor ablation of the liver allows early assessment of the ablation zone.
Collapse
|
44
|
Ahmed M, Solbiati L, Brace CL, Breen DJ, Callstrom MR, Charboneau JW, Chen MH, Choi BI, de Baère T, Dodd GD, Dupuy DE, Gervais DA, Gianfelice D, Gillams AR, Lee FT, Leen E, Lencioni R, Littrup PJ, Livraghi T, Lu DS, McGahan JP, Meloni MF, Nikolic B, Pereira PL, Liang P, Rhim H, Rose SC, Salem R, Sofocleous CT, Solomon SB, Soulen MC, Tanaka M, Vogl TJ, Wood BJ, Goldberg SN. Image-guided tumor ablation: standardization of terminology and reporting criteria--a 10-year update. J Vasc Interv Radiol 2014; 25:1691-705.e4. [PMID: 25442132 PMCID: PMC7660986 DOI: 10.1016/j.jvir.2014.08.027] [Citation(s) in RCA: 358] [Impact Index Per Article: 32.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2013] [Revised: 02/11/2014] [Accepted: 03/26/2014] [Indexed: 12/12/2022] Open
Abstract
Image-guided tumor ablation has become a well-established hallmark of local cancer therapy. The breadth of options available in this growing field increases the need for standardization of terminology and reporting criteria to facilitate effective communication of ideas and appropriate comparison among treatments that use different technologies, such as chemical (eg, ethanol or acetic acid) ablation, thermal therapies (eg, radiofrequency, laser, microwave, focused ultrasound, and cryoablation) and newer ablative modalities such as irreversible electroporation. This updated consensus document provides a framework that will facilitate the clearest communication among investigators regarding ablative technologies. An appropriate vehicle is proposed for reporting the various aspects of image-guided ablation therapy including classification of therapies, procedure terms, descriptors of imaging guidance, and terminology for imaging and pathologic findings. Methods are addressed for standardizing reporting of technique, follow-up, complications, and clinical results. As noted in the original document from 2003, adherence to the recommendations will improve the precision of communications in this field, leading to more accurate comparison of technologies and results, and ultimately to improved patient outcomes.
Collapse
Affiliation(s)
- Muneeb Ahmed
- Department of Radiology, Beth Israel Deaconess Medical Center 1 Deaconess Rd, WCC-308B, Boston, MA 02215.
| | - Luigi Solbiati
- Department of Radiology, Ospedale Generale, Busto Arsizio, Italy
| | - Christopher L Brace
- Departments of Radiology, Biomedical Engineering, and Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
| | - David J Breen
- Department of Radiology, Southampton University Hospitals, Southampton, England
| | | | | | - Min-Hua Chen
- Department of Ultrasound, School of Oncology, Peking University, Beijing, China
| | - Byung Ihn Choi
- Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea
| | - Thierry de Baère
- Department of Imaging, Institut de Cancérologie Gustave Roussy, Villejuif, France
| | - Gerald D Dodd
- Department of Radiology, School of Medicine, University of Colorado Anschutz Medical Campus, Aurora, Colorado
| | - Damian E Dupuy
- Department of Diagnostic Radiology, Rhode Island Hospital, Providence, Rhode Island
| | - Debra A Gervais
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| | - David Gianfelice
- Medical Imaging, University Health Network, Laval, Quebec, Canada
| | | | - Fred T Lee
- Department of Radiology, University of Wisconsin Hospital and Clinics, Madison, Wisconsin
| | - Edward Leen
- Department of Radiology, Royal Infirmary, Glasgow, Scotland
| | - Riccardo Lencioni
- Department of Diagnostic Imaging and Intervention, Cisanello Hospital, Pisa University Hospital and School of Medicine, University of Pisa, Pisa, Italy
| | - Peter J Littrup
- Department of Radiology, Karmonos Cancer Institute, Wayne State University, Detroit, Michigan
| | | | - David S Lu
- Department of Radiology, David Geffen School of Medicine at UCLA, Los Angeles, California
| | - John P McGahan
- Department of Radiology, Ambulatory Care Center, UC Davis Medical Center, Sacramento, California
| | | | - Boris Nikolic
- Department of Radiology, Albert Einstein Medical Center, Philadelphia, Pennsylvania
| | - Philippe L Pereira
- Clinic of Radiology, Minimally-Invasive Therapies and Nuclear Medicine, Academic Hospital Ruprecht-Karls-University Heidelberg, Heilbronn, Germany
| | - Ping Liang
- Department of Interventional Ultrasound, Chinese PLA General Hospital, Beijing, China
| | - Hyunchul Rhim
- Department of Diagnostic Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Steven C Rose
- Department of Radiology, University of California, San Diego, San Diego, California
| | - Riad Salem
- Department of Radiology, Northwestern University, Chicago, Illinois
| | | | - Stephen B Solomon
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Michael C Soulen
- Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | | | - Thomas J Vogl
- Institute for Diagnostic and Interventional Radiology, University Hospital Frankfurt, Johann Wolfgang Goethe-University, Frankfurt, Germany
| | - Bradford J Wood
- Radiology and Imaging Science, National Institutes of Health, Bethesda, Maryland
| | - S Nahum Goldberg
- Department of Radiology, Image-Guided Therapy and Interventional Oncology Unit, Hadassah Hebrew University Medical Center, Jerusalem, Israel
| |
Collapse
|
45
|
Vandenbroucke F, Vandemeulebroucke J, Ilsen B, Verdries D, Belsack D, Everaert H, Buls N, Ros PR, de Mey J. Predictive Value of Pattern Classification 24 Hours after Radiofrequency Ablation of Liver Metastases on CT and Positron Emission Tomography/CT. J Vasc Interv Radiol 2014; 25:1240-9. [DOI: 10.1016/j.jvir.2014.04.020] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2013] [Revised: 04/03/2014] [Accepted: 04/24/2014] [Indexed: 01/20/2023] Open
|
46
|
Floridi C, Radaelli A, Abi-Jaoudeh N, Grass M, Lin M, Chiaradia M, Geschwind JF, Kobeiter H, Squillaci E, Maleux G, Giovagnoni A, Brunese L, Wood B, Carrafiello G, Rotondo A. C-arm cone-beam computed tomography in interventional oncology: technical aspects and clinical applications. Radiol Med 2014; 119:521-32. [PMID: 25012472 DOI: 10.1007/s11547-014-0429-5] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2014] [Accepted: 06/16/2014] [Indexed: 12/12/2022]
Abstract
C-arm cone-beam computed tomography (CBCT) is a new imaging technology integrated in modern angiographic systems. Due to its ability to obtain cross-sectional imaging and the possibility to use dedicated planning and navigation software, it provides an informed platform for interventional oncology procedures. In this paper, we highlight the technical aspects and clinical applications of CBCT imaging and navigation in the most common loco-regional oncological treatments.
Collapse
Affiliation(s)
- Chiara Floridi
- Radiology Department, Insubria University, Viale Borri 57, 21100, Varese, Italy,
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
47
|
Ahmed M, Solbiati L, Brace CL, Breen DJ, Callstrom MR, Charboneau JW, Chen MH, Choi BI, de Baère T, Dodd GD, Dupuy DE, Gervais DA, Gianfelice D, Gillams AR, Lee FT, Leen E, Lencioni R, Littrup PJ, Livraghi T, Lu DS, McGahan JP, Meloni MF, Nikolic B, Pereira PL, Liang P, Rhim H, Rose SC, Salem R, Sofocleous CT, Solomon SB, Soulen MC, Tanaka M, Vogl TJ, Wood BJ, Goldberg SN. Image-guided tumor ablation: standardization of terminology and reporting criteria--a 10-year update. Radiology 2014; 273:241-60. [PMID: 24927329 DOI: 10.1148/radiol.14132958] [Citation(s) in RCA: 876] [Impact Index Per Article: 79.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Image-guided tumor ablation has become a well-established hallmark of local cancer therapy. The breadth of options available in this growing field increases the need for standardization of terminology and reporting criteria to facilitate effective communication of ideas and appropriate comparison among treatments that use different technologies, such as chemical (eg, ethanol or acetic acid) ablation, thermal therapies (eg, radiofrequency, laser, microwave, focused ultrasound, and cryoablation) and newer ablative modalities such as irreversible electroporation. This updated consensus document provides a framework that will facilitate the clearest communication among investigators regarding ablative technologies. An appropriate vehicle is proposed for reporting the various aspects of image-guided ablation therapy including classification of therapies, procedure terms, descriptors of imaging guidance, and terminology for imaging and pathologic findings. Methods are addressed for standardizing reporting of technique, follow-up, complications, and clinical results. As noted in the original document from 2003, adherence to the recommendations will improve the precision of communications in this field, leading to more accurate comparison of technologies and results, and ultimately to improved patient outcomes. Online supplemental material is available for this article .
Collapse
Affiliation(s)
- Muneeb Ahmed
- Department of Radiology, Beth Israel Deaconess Medical Center 1 Deaconess Rd, WCC-308B, Boston, MA 02215 (M.A.); Department of Radiology, Ospedale Generale, Busto Arsizio, Italy (L.S.); Departments of Radiology, Biomedical Engineering, and Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wis (C.L.B.); Department of Radiology, Southampton University Hospitals, Southampton, England (D.J.B.); Department of Radiology, Mayo Clinic, Rochester, Minn (M.R.C., J.W.C.); Department of Ultrasound, School of Oncology, Peking University, Beijing, China (M.H.C.); Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea (B.I.C.); Department of Imaging, Institut de Cancérologie Gustave Roussy, Villejuif, France (T.d.B.); Department of Radiology, School of Medicine, University of Colorado Anschutz Medical Campus, Aurora, Colo (G.D.D.); Department of Diagnostic Radiology, Rhode Island Hospital, Providence, RI (D.E.D.); Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (D.A.G.); Medical Imaging, University Health Network, Laval, Quebec, Canada (D.G.); Imaging Department, the London Clinic, London, England (A.R.G.); Department of Radiology, University of Wisconsin Hospital and Clinics, Madison, Wis (F.T.L.); Department of Radiology, Royal Infirmary, Glasgow, Scotland (E.L.); Department of Diagnostic Imaging and Intervention, Cisanello Hospital, Pisa University Hospital and School of Medicine, University of Pisa, Pisa, Italy (R.L.); Department of Radiology, Karmonos Cancer Institute, Wayne State University, Detroit, Mich (P.J.L.); Busto Arsizio, Italy (T.L.); Department of Radiology, David Geffen School of Medicine at UCLA, Los Angeles, Calif (D.S.L.); Department of Radiology, Ambulatory Care Center, UC Davis Medical Center, Sacramento, Calif (J.P.M.); Department of Radiology, Ospedale Valduce, Como, Italy (M.F.M.); Department of Radiology, Albert Einstein Medical Center, Phil
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
48
|
Percutaneous bone biopsies: comparison between flat-panel cone-beam CT and CT-scan guidance. Cardiovasc Intervent Radiol 2014; 38:167-76. [PMID: 24627161 DOI: 10.1007/s00270-014-0870-9] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2013] [Accepted: 01/27/2014] [Indexed: 01/18/2023]
Abstract
PURPOSE This study was designed to compare the accuracy of targeting and the radiation dose of bone biopsies performed either under fluoroscopic guidance using a cone-beam CT with real-time 3D image fusion software (FP-CBCT-guidance) or under conventional computed tomography guidance (CT-guidance). METHODS Sixty-eight consecutive patients with a bone lesion were prospectively included. The bone biopsies were scheduled under FP-CBCT-guidance or under CT-guidance according to operating room availability. Thirty-four patients underwent a bone biopsy under FP-CBCT and 34 under CT-guidance. We prospectively compared the two guidance modalities for their technical success, accuracy, puncture time, and pathological success rate. Patient and physician radiation doses also were compared. RESULTS All biopsies were technically successful, with both guidance modalities. Accuracy was significantly better using FP-CBCT-guidance (3 and 5 mm respectively: p = 0.003). There was no significant difference in puncture time (32 and 31 min respectively, p = 0.51) nor in pathological results (88 and 88 % of pathological success respectively, p = 1). Patient radiation doses were significantly lower with FP-CBCT (45 vs. 136 mSv, p < 0.0001). The percentage of operators who received a dose higher than 0.001 mSv (dosimeter detection dose threshold) was lower with FP-CBCT than CT-guidance (27 vs. 59 %, p = 0.01). CONCLUSIONS FP-CBCT-guidance for bone biopsy is accurate and reduces patient and operator radiation doses compared with CT-guidance.
Collapse
|
49
|
Koethe Y, Xu S, Velusamy G, Wood BJ, Venkatesan AM. Accuracy and efficacy of percutaneous biopsy and ablation using robotic assistance under computed tomography guidance: a phantom study. Eur Radiol 2014; 24:723-30. [PMID: 24220755 PMCID: PMC3945277 DOI: 10.1007/s00330-013-3056-y] [Citation(s) in RCA: 63] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2013] [Revised: 09/24/2013] [Accepted: 10/10/2013] [Indexed: 02/06/2023]
Abstract
OBJECTIVE To compare the accuracy of a robotic interventional radiologist (IR) assistance platform with a standard freehand technique for computed-tomography (CT)-guided biopsy and simulated radiofrequency ablation (RFA). METHODS The accuracy of freehand single-pass needle insertions into abdominal phantoms was compared with insertions facilitated with the use of a robotic assistance platform (n = 20 each). Post-procedural CTs were analysed for needle placement error. Percutaneous RFA was simulated by sequentially placing five 17-gauge needle introducers into 5-cm diameter masses (n = 5) embedded within an abdominal phantom. Simulated ablations were planned based on pre-procedural CT, before multi-probe placement was executed freehand. Multi-probe placement was then performed on the same 5-cm mass using the ablation planning software and robotic assistance. Post-procedural CTs were analysed to determine the percentage of untreated residual target. RESULTS Mean needle tip-to-target errors were reduced with use of the IR assistance platform (both P < 0.0001). Reduced percentage residual tumour was observed with treatment planning (P = 0.02). CONCLUSION Improved needle accuracy and optimised probe geometry are observed during simulated CT-guided biopsy and percutaneous ablation with use of a robotic IR assistance platform. This technology may be useful for clinical CT-guided biopsy and RFA, when accuracy may have an impact on outcome. KEY POINTS • A recently developed robotic intervention radiology assistance platform facilitates CT-guided interventions. • Improved accuracy of complex needle insertions is achievable. • IR assistance platform use can improve target ablation coverage.
Collapse
Affiliation(s)
- Yilun Koethe
- Center for Interventional Oncology, NIH Clinical Center, National Institutes of Health, Bethesda, MD, USA
| | | | | | | | | |
Collapse
|
50
|
|