1
|
Panda A, Francois CJ, Bookwalter CA, Chaturvedi A, Collins JD, Leiner T, Rajiah PS. Non-Contrast Magnetic Resonance Angiography: Techniques, Principles, and Applications. Magn Reson Imaging Clin N Am 2023; 31:337-360. [PMID: 37414465 DOI: 10.1016/j.mric.2023.04.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/08/2023]
Abstract
Several non-contrast magnetic resonance angiography (MRA) techniques have been developed, providing an attractive alternative to contrast-enhanced MRA and a radiation-free alternative to computed tomography (CT) CT angiography. This review describes the physical principles, limitations, and clinical applications of bright-blood (BB) non-contrast MRA techniques. The principles of BB MRA techniques can be broadly divided into (a) flow-independent MRA, (b) blood-inflow-based MRA, (c) cardiac phase dependent, flow-based MRA, (d) velocity sensitive MRA, and (e) arterial spin-labeling MRA. The review also includes emerging multi-contrast MRA techniques that provide simultaneous BB and black-blood images for combined luminal and vessel wall evaluation.
Collapse
Affiliation(s)
- Ananya Panda
- Department of Radiology, All India Institute of Medical Sciences, Jodhpur, India
| | | | | | - Abhishek Chaturvedi
- Department of Radiology, University of Rochester Medical Center, Rochester, NY, USA
| | | | - Tim Leiner
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | | |
Collapse
|
2
|
Zun Z, Shin T. Velocity-selective excitation: Principles and applications. NMR IN BIOMEDICINE 2023; 36:e4820. [PMID: 35994473 PMCID: PMC9845137 DOI: 10.1002/nbm.4820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Revised: 07/12/2022] [Accepted: 08/16/2022] [Indexed: 06/15/2023]
Abstract
Velocity-selective (VS) excitation is a relatively new type of excitation that can be useful for generating image contrast based on spin's motion. This review aims to explain the principles of VS excitation and their utilization for clinical applications. We first review the generalized excitation k-space formalism, which reveals a Fourier relationship between sequence parameters and excitation profiles for spins with arbitrary spatial location, off-resonance, and velocity. Based on the k-space framework, we analyze practical VS excitation pulse sequences that yield sinusoidal or sinc-shaped velocity profiles. Then we demonstrate how these two types of VS excitation can be used as magnetization preparation for clinical applications, including saturation- or inversion-based arterial spin labeling and black- or bright-blood angiography. We also discuss practical considerations and issues for each application, including the determination of design parameters and the effects of MR system errors, such as magnetic field offsets and eddy currents.
Collapse
Affiliation(s)
- Zungho Zun
- Department of Radiology, Weill Cornell Medicine, New York, NY, United States
| | - Taehoon Shin
- Division of Mechanical and Biomedical Engineering, Ewha Womans University, Seoul, South Korea
- Graduate Program in Smart Factory, Ewha Womans University, Seoul, South Korea
- Department of Medicine, Case Western Reserve University, Cleveland, OH, United States
| |
Collapse
|
3
|
Liu Z, Zhao M, Wang H, Fu Z, Gao H, Peng W, Ni D, Tang W, Gu Y. High relaxivity Gd 3+-based organic nanoparticles for efficient magnetic resonance angiography. J Nanobiotechnology 2022; 20:170. [PMID: 35361219 PMCID: PMC8973627 DOI: 10.1186/s12951-022-01363-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Accepted: 03/09/2022] [Indexed: 01/29/2023] Open
Abstract
Contrast-enhanced MR angiography (MRA) is a critical technique for vascular imaging. Nevertheless, the efficacy of MRA is often limited by the low rate of relaxation, short blood-circulation time, and metal ion-released potential long-term toxicity of clinical available Gd-based contrast agents. In this work, we report a facile and efficient strategy to achieve Gd-chelated organic nanoparticles with high relaxivity for T1-weighted MRA imaging. The Gd-chelated PEG-TCPP nanoparticles (GPT NPs) have been engineered composite structured consisting of Gd-chelated TCPP and PEG. The spherical structure of TCPP offers more chemical sites for Gd3+ coordination to improve the relaxivity and avoid leakage of the Gd3+ ions. The synthesized GPT NPs exhibit a high relaxation rate of 35.76 mM− 1 s− 1 at 3.0 T, which is higher than the rates for most reported MR contrast agents. Therefore, GPT NPs can be used for MRA with much stronger vascular signals, longer circulation time, and high-resolution arterial vascular visualization than those using clinical MR contrast agents at the same dose. This work may make the T1 MRI contrast agents for high-resolution angiography possible and offer a new candidate for preclinical and clinical applications of MR vascular imaging and vascular disease diagnosis.
Collapse
Affiliation(s)
- Zhuang Liu
- Department of Radiology, Fudan University Shanghai Cancer Center, Shanghai, 200032, China.,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, 200032, China
| | - Menglong Zhao
- Department of Radiology, Zhongshan Hospital, Fudan University and Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Han Wang
- Department of Orthopaedics, Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China
| | - Zi Fu
- Department of Radiology, Fudan University Shanghai Cancer Center, Shanghai, 200032, China.,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, 200032, China.,Department of Orthopaedics, Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China
| | - Hongbo Gao
- Department of Radiation Oncology, Huadong Hospital Affiliated to Fudan University, Shanghai, 200040, China
| | - Weijun Peng
- Department of Radiology, Fudan University Shanghai Cancer Center, Shanghai, 200032, China.,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, 200032, China
| | - Dalong Ni
- Department of Orthopaedics, Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China.
| | - Wei Tang
- Department of Radiology, Fudan University Shanghai Cancer Center, Shanghai, 200032, China. .,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, 200032, China.
| | - Yajia Gu
- Department of Radiology, Fudan University Shanghai Cancer Center, Shanghai, 200032, China. .,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, 200032, China.
| |
Collapse
|
4
|
Liu B, Cai J, Tian X, Huang K, Liu D, Zheng H, Wang L, Yang J, Xu H. Preoperative MRI Evaluation of Hand Vessels in Children With Congenital Syndactyly Malformation by a Contrast-Enhanced Three-Dimensional Water-Selective Cartilage Scan. Front Pediatr 2022; 10:880954. [PMID: 35463876 PMCID: PMC9019362 DOI: 10.3389/fped.2022.880954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Accepted: 03/16/2022] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND It is crucial to preoperatively assess the arteries of the hands in congenital syndactyly malformation (CSM) patients because this information can affect the therapeutic outcome and prognosis. OBJECTIVE To investigate the value of a contrast-enhanced three-dimensional water-selective cartilage scan for the preoperative evaluation of CSM in children. MATERIALS AND METHODS Contrast-enhanced three-dimensional water-selective cartilage scan 3.0 T magnetic resonance imaging (MRI) performed in 16 clinically diagnosed CSM patients with 17 affected hands. The arteries of the hands were displayed with a focus on the bifurcation position of the common palmar digital arteries (CPDAs) and the maturity of the proper palmar digital arteries (PPDAs). The MRI results were interpreted by consensus between two experienced pediatric radiologists with 10 years of MRI experience each. The MRI findings were compared with the operation results. RESULTS Of 51 CPDAs in the 17 affected hands, MRI showed that 30 had an abnormal bifurcation position and 20 had a normal position, and of the 102 PPDAs, 14 were shown to have an abnormal maturity and 85 a normal state, which were confirmed by surgery. The accuracy, sensitivity and specificity for determining the bifurcation position of the CPDAs based on MR maximum intensity projection reconstructed images were 98.04% (50/51), 96.77% (30/31) and 100% (20/20), respectively. The maturity of the PPDAs was judged by MR maximum intensity projection reconstructed images with an accuracy, sensitivity and specificity of 97.06% (99/102), 82.35% (14/17) and 100% (85/85), respectively. CONCLUSION Contrast-enhanced three-dimensional water-selective cartilage scan has excellent performance in displaying the bifurcation position of the CPDAs and the maturity of the PPDAs and is of high value for the preoperative evaluation of CSM in children.
Collapse
Affiliation(s)
- Bo Liu
- Department of Radiology, Children's Hospital of Chongqing Medical University, Chongqing, China.,Ministry of Education Key Laboratory of Child Development and Disorders, Children's Hospital of Chongqing Medical University, Chongqing, China.,National Clinical Research Center for Child Health and Disorders, Children's Hospital of Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory of Pediatrics, Children's Hospital of Chongqing Medical University, Chongqing, China
| | - Jinhua Cai
- Department of Radiology, Children's Hospital of Chongqing Medical University, Chongqing, China.,Ministry of Education Key Laboratory of Child Development and Disorders, Children's Hospital of Chongqing Medical University, Chongqing, China.,National Clinical Research Center for Child Health and Disorders, Children's Hospital of Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory of Pediatrics, Children's Hospital of Chongqing Medical University, Chongqing, China
| | - Xiaofei Tian
- Ministry of Education Key Laboratory of Child Development and Disorders, Children's Hospital of Chongqing Medical University, Chongqing, China.,National Clinical Research Center for Child Health and Disorders, Children's Hospital of Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory of Pediatrics, Children's Hospital of Chongqing Medical University, Chongqing, China.,Department of Burn and Plastic Surgery, Children's Hospital of Chongqing Medical University, Chongqing, China
| | - Kaiping Huang
- Department of Radiology, Children's Hospital of Chongqing Medical University, Chongqing, China
| | - Daisong Liu
- Department of Radiology, Children's Hospital of Chongqing Medical University, Chongqing, China
| | - Helin Zheng
- Department of Radiology, Children's Hospital of Chongqing Medical University, Chongqing, China
| | - Longlun Wang
- Department of Radiology, Children's Hospital of Chongqing Medical University, Chongqing, China
| | - Jing Yang
- Department of Radiology, Children's Hospital of Chongqing Medical University, Chongqing, China
| | - Hongrong Xu
- Department of Radiology, Children's Hospital of Chongqing Medical University, Chongqing, China
| |
Collapse
|
5
|
Noncontrast Magnetic Resonance Angiography in the Era of Nephrogenic Systemic Fibrosis and Gadolinium Deposition. J Comput Assist Tomogr 2021; 45:37-51. [PMID: 32976265 DOI: 10.1097/rct.0000000000001074] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
ABSTRACT Gadolinium-based contrast agents for clinical magnetic resonance imaging are overall safe. However, the discovery of nephrogenic systemic fibrosis in patients with severe renal impairment and gadolinium deposition in patients receiving contrast have generated developments in contrast-free imaging of the vasculature, that is, noncontrast magnetic resonance angiography. This article presents an update on noncontrast magnetic resonance angiography techniques, with comparison to other imaging alternatives. Potential benefits and challenges to implementation, and evidence to date for various clinical applications are discussed.
Collapse
|
6
|
Shibukawa S, Saito M, Niwa T, Obara M, Konta N, Hara T, Okazaki T, Nomura T. Optimized enhanced acceleration selective arterial spin labeling (eAccASL) for non-gated and non-enhanced MR angiography of the hands. Magn Reson Imaging 2021; 78:1-6. [PMID: 33486082 DOI: 10.1016/j.mri.2021.01.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Revised: 12/13/2020] [Accepted: 01/16/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE Enhanced acceleration selective arterial spin labeling (eAccASL) was introduced as non-enhanced and non-gated magnetic resonance angiography (MRA). This technique has not been applied to hand MRA. The objective of this study was to optimize the eAccASL for MRA of the hands and to investigate the factors for MRA visibility of the hands. METHODS Twenty healthy volunteers were examined on a 1.5 T MR system. To evaluate arterial visualization, we compared four different acceleration-encoding (AENC) values (i.e., 0.12, 0.29, 0.58, and 0.87 m/s2). Image quality score regarding the MRA depiction of the proximal artery (range, 0-10), the distal artery (0-5), and venous contamination (0-5) was evaluated by three radiologists. We measured the peak to peak arterial blood flow velocity (Vpp) measured by phase contrast cine MRI and hand temperature as the factors for arterial visualization. Qualitative scores were compared with Friedman's tests. Spearman's correlation of qualitative scores with Vpp and hand temperature was performed to analyze influencing factors. RESULTS For the distal arterial depiction, scores at AENC 0.12 (median, 9.0) and AENC 0.29 (8.0) were significantly better (both P < 0.0001) than those at AENC 0.87 (5.5). For the proximal arterial depiction, scores at AENC 0.12 (2.25) and AENC 0.29 (2.0) were significantly better (P < 0.001 and P < 0.01, respectively) than those at AENC 0.87 (1.5). Conversely, venous contamination scores at AENC 0.12 (3.0) and AENC 0.29 (3.0) were significantly worse (both P < 0.0001) than those at AENC 0.87 (4.0). There were significantly negative correlations between venous contamination and Vpp at AENC 0.12 (ρ = -0.56, P = 0.01), and 0.29 (ρ = -0.68, P = 0.001), whereas hand temperatures were not significantly correlated with scores (all P > 0.05). CONCLUSION eAccASL MRA of the hands was optimized by using low AENC values (0.12-0.29 m/s2). Venous contamination may increase with elevation of arterial blood flow.
Collapse
Affiliation(s)
- Shuhei Shibukawa
- Department of Radiology, Tokai University Hospital, Isehara, Kanagawa, Japan.
| | - Misaki Saito
- Department of Radiology, Tokai University Hospital, Isehara, Kanagawa, Japan
| | - Tetsu Niwa
- Department of Radiology, Tokai University School of Medicine, Isehara, Kanagawa, Japan
| | | | - Natsuo Konta
- Department of Radiology, Tokai University Hospital, Isehara, Kanagawa, Japan
| | - Takuya Hara
- Department of Radiology, Tokai University School of Medicine, Isehara, Kanagawa, Japan
| | - Takashi Okazaki
- Department of Radiology, Tokai University School of Medicine, Isehara, Kanagawa, Japan
| | - Takakiyo Nomura
- Department of Radiology, Tokai University School of Medicine, Isehara, Kanagawa, Japan
| |
Collapse
|
7
|
Li H, Wang S, Graves MJ, Lomas DJ, Priest AN. Subtractive NCE-MRA: Improved background suppression using robust regression-based weighted subtraction. Magn Reson Med 2020; 85:694-708. [PMID: 32754954 DOI: 10.1002/mrm.28443] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2020] [Revised: 06/30/2020] [Accepted: 07/03/2020] [Indexed: 11/09/2022]
Abstract
PURPOSE To correct the intensity difference of static background signal between bright blood images and dark blood images in subtractive non-contrast-enhanced MR angiography using robust regression, thereby improving static background signal suppression on subtracted angiograms. METHODS Robust regression (RR), using iteratively reweighted least squares, is used to calculate the regression coefficient of background tissues from a scatter plot showing the voxel intensity of bright blood images versus dark blood images. The weighting function is based on either the Euclidean distance from the estimated regression line or the deviation angle. Results from RR using the deviation angle (RRDA), conventional RR using the Euclidean distance, and ordinary leastsquares regression were compared with reference values determined manually by two observers. Performance was evaluated over studies using different sequences, including 36 thoracic flow-sensitive dephasing data sets, 13 iliac flow-sensitive dephasing data sets, and 26 femoral fresh blood imaging data sets. RESULTS RR deviation angle achieved robust and accurate performance in all types of images, with small bias, small mean absolute error, and high-correlation coefficients with reference values. Background tissues, such as muscle, veins, and bladder, were suppressed while the vascular signal was preserved. Euclidean distance gave good performance for thoracic and iliac flow-sensitive dephasing, but could not suppress background tissues in femoral fresh blood imaging. Ordinary least squares regression was sensitive to outliers and overestimated regression coefficients in thoracic flow-sensitive dephasing. CONCLUSION Weighted subtraction using RR was able to acquire the regression coefficients of background signal and improve background suppression of subtractive non-contrast-enhanced MR angiography techniques. RR deviation angle has the most robust and accurate overall performance among three regression methods.
Collapse
Affiliation(s)
- Hao Li
- Department of Radiology, University of Cambridge, Cambridge, UK
| | - Shuo Wang
- Department of Radiology, University of Cambridge, Cambridge, UK.,Data Science Institute, Imperial College London, London, UK
| | - Martin J Graves
- Department of Radiology, University of Cambridge, Cambridge, UK.,Department of Radiology, Addenbrooke's Hospital, Cambridge, UK
| | - David J Lomas
- Department of Radiology, University of Cambridge, Cambridge, UK.,Department of Radiology, Addenbrooke's Hospital, Cambridge, UK
| | - Andrew N Priest
- Department of Radiology, University of Cambridge, Cambridge, UK.,Department of Radiology, Addenbrooke's Hospital, Cambridge, UK
| |
Collapse
|
8
|
Soudet S, Le Joncour A, Quemeneur T, Maillard H, Koskas F, Hachulla E, Cacoub P, Yelnik CM, Saadoun D, Lambert M. Did the Clinical Spectrum of Thromboangiitis Obliterans Change in the Past 40 Years? Angiology 2020; 71:621-625. [PMID: 32319306 DOI: 10.1177/0003319720920163] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Thromboangiitis obliterans (TAO) is an inflammatory disease that usually affects small and medium-sized arteries in the upper and lower limbs of young smokers. Previous studies showed that the spectrum TAO has changed in the 80s: the male-to-female ratio decreased, older patients were diagnosed, and upper limb involvement was more common. The aim of our study was to assess the changing clinical spectrum of TAO in France during the past 40 years. All consecutive patients fulfilling TAO's criteria between January 1967 and January 2016 were retrospectively included in 3 departments of internal medicine. We compared TAO features in patients diagnosed before and after 2002; 141 (77.5%) men and 41 (22.5%) women were included. Patients diagnosed after 2002 were older (37 [31-39] vs 34 [29-35] years P = .03), had a more frequent isolated upper limb involvement (34.3% vs 7.8% P = .001), and less frequent isolated lower limb involvement (55.7% vs 74.5%, P < .001). The clinical spectrum of TAO has changed in France since the beginning of the 21st century.
Collapse
Affiliation(s)
- Simon Soudet
- Department of Internal Medicine, Hôpital HURIEZ, CHRU Lille, France
| | - Alexandre Le Joncour
- Department of Internal Medicine and Clinical Immunology, Centre de Référence des Maladies Auto-Immunes et Systémiques Rares, des Maladies Auto-Inflammatoires et de l'Amylose, Paris, France.,AP-HP, Groupe Hospitalier Pitié-Salpêtrière, Paris, France.,Sorbonne Université, UPMC Univ Paris 06, UMR 7211, France
| | - Thomas Quemeneur
- Department of Nephrology and Internal Medicine, Valenciennes Hospital, France
| | - Helene Maillard
- Department of Internal Medicine, Hôpital HURIEZ, CHRU Lille, France
| | - Fabien Koskas
- Department of Vascular Surgery, Assistance Publique des Hôpitaux de Paris, Hôpital Pitié Salpêtrière, Paris, France
| | - Eric Hachulla
- Department of Internal Medicine, Hôpital HURIEZ, CHRU Lille, France
| | - Patrice Cacoub
- Department of Internal Medicine and Clinical Immunology, Centre de Référence des Maladies Auto-Immunes et Systémiques Rares, des Maladies Auto-Inflammatoires et de l'Amylose, Paris, France.,AP-HP, Groupe Hospitalier Pitié-Salpêtrière, Paris, France.,Sorbonne Université, UPMC Univ Paris 06, UMR 7211, France
| | - Cecile M Yelnik
- Department of Internal Medicine, Hôpital HURIEZ, CHRU Lille, France
| | - David Saadoun
- Department of Internal Medicine and Clinical Immunology, Centre de Référence des Maladies Auto-Immunes et Systémiques Rares, des Maladies Auto-Inflammatoires et de l'Amylose, Paris, France.,AP-HP, Groupe Hospitalier Pitié-Salpêtrière, Paris, France.,Sorbonne Université, UPMC Univ Paris 06, UMR 7211, France
| | - Marc Lambert
- Department of Internal Medicine, Hôpital HURIEZ, CHRU Lille, France
| |
Collapse
|
9
|
Ghouri MA, Gupta N, Bhat AP, Thimmappa ND, Saboo SS, Khandelwal A, Nagpal P. CT and MR imaging of the upper extremity vasculature: pearls, pitfalls, and challenges. Cardiovasc Diagn Ther 2019; 9:S152-S173. [PMID: 31559161 DOI: 10.21037/cdt.2018.09.15] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
Imaging is needed for diagnosis, treatment planning, and follow-up of patients with pathologies affecting upper extremity vasculature. With growth and evolution of imaging modalities [especially CT angiography (CTA) and MR angiography (MRA)], there is need to recognize the advantages and disadvantages of various modalities and obtain the best possible imaging diagnostic test. Understanding various limitations and pitfalls as well as the best practices to minimize and manage these pitfalls is very important for the diagnosis. This article reviews the upper extremity arterial vascular anatomy, discusses the CTA and MRA imaging, various pitfalls, and challenges and discuss imaging manifestations of upper extremity arterial pathologies.
Collapse
Affiliation(s)
- Maaz A Ghouri
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - Nishant Gupta
- Department of Radiology, Columbia University Medical Center, New York, NY, USA
| | - Ambarish P Bhat
- Department of Radiology, University of Missouri, Columbia, MO, USA
| | | | - Sachin S Saboo
- Department of Radiology, UT Health Science Center, San Antonio, TX, USA
| | | | - Prashant Nagpal
- Department of Radiology, University of Iowa Hospital and Clinics, Iowa City, IA, USA
| |
Collapse
|
10
|
Li H, Priest AN, Patterson I, Graves MJ, Lomas DJ. Subtractive non‐contrast‐enhanced MRI of lower limb veins using multiple flow‐dependent preparation strategies. Magn Reson Med 2018; 81:1769-1783. [DOI: 10.1002/mrm.27530] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2018] [Revised: 07/30/2018] [Accepted: 08/24/2018] [Indexed: 12/12/2022]
Affiliation(s)
- Hao Li
- Department of Radiology University of Cambridge Cambridge United Kingdom
| | - Andrew N. Priest
- Department of Radiology Addenbrooke’s Hospital Cambridge United Kingdom
| | - Ilse Patterson
- Department of Radiology Addenbrooke’s Hospital Cambridge United Kingdom
| | - Martin J Graves
- Department of Radiology Addenbrooke’s Hospital Cambridge United Kingdom
| | - David J Lomas
- Department of Radiology University of Cambridge Cambridge United Kingdom
| |
Collapse
|
11
|
Cervantes B, Kirschke JS, Klupp E, Kooijman H, Börnert P, Haase A, Rummeny EJ, Karampinos DC. Orthogonally combined motion- and diffusion-sensitized driven equilibrium (OC-MDSDE) preparation for vessel signal suppression in 3D turbo spin echo imaging of peripheral nerves in the extremities. Magn Reson Med 2017; 79:407-415. [DOI: 10.1002/mrm.26660] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2016] [Revised: 02/06/2017] [Accepted: 02/07/2017] [Indexed: 01/28/2023]
Affiliation(s)
- Barbara Cervantes
- Department of Diagnostic and Interventional Radiology; Technische Universität München; Munich Germany
| | - Jan S. Kirschke
- Department of Neuroradiology; Technische Universität München; Munich Germany
| | - Elizabeth Klupp
- Department of Neuroradiology; Technische Universität München; Munich Germany
| | | | | | - Axel Haase
- Institute of Medical Engineering; Technische Universität München; Garching Germany
| | - Ernst J. Rummeny
- Department of Diagnostic and Interventional Radiology; Technische Universität München; Munich Germany
| | - Dimitrios C. Karampinos
- Department of Diagnostic and Interventional Radiology; Technische Universität München; Munich Germany
| |
Collapse
|
12
|
Jin W, Zhang G, Liu H, Zhang H, Li B, Zhu X. Non-contrast-enhanced MR angiography for detecting arteriovenous fistula dysfunction in haemodialysis patients. Clin Radiol 2015; 70:852-7. [PMID: 25976499 DOI: 10.1016/j.crad.2015.04.005] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2014] [Revised: 03/18/2015] [Accepted: 04/09/2015] [Indexed: 11/26/2022]
|
13
|
Zhang N, Zou L, Huang Y, Liu D, Tang Y, Fan Z, Chen H, Liu X. Non-Contrast Enhanced MR Angiography (NCE-MRA) of the Calf: A Direct Comparison between Flow-Sensitive Dephasing (FSD) Prepared Steady-State Free Precession (SSFP) and Quiescent-Interval Single-Shot (QISS) in Patients with Diabetes. PLoS One 2015; 10:e0128786. [PMID: 26035645 PMCID: PMC4452776 DOI: 10.1371/journal.pone.0128786] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2014] [Accepted: 04/30/2015] [Indexed: 11/25/2022] Open
Abstract
Objectives To compare the image quality and diagnostic performance of two non-contrast enhanced MR angiography (NCE-MRA) techniques using flow-sensitive dephasing (FSD) prepared steady-state free precession (SSFP) and quiescent-interval single-shot (QISS) for the calf arteries in patients with diabetes. Materials and Methods Twenty six patients underwent the two NCE-MRA techniques followed by contrast-enhanced MRA (CE-MRA) of lower extremity on a 1.5T MR system. Image quality scores, arterial stenosis scores, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel sharpness, and diagnostic accuracy for detecting more than 50% arterial stenosis were evaluated and statistically compared using CE-MRA as the reference standard. Results All examinations were performed successfully. Of the total 153 calf arterial segments obtained in the 26 patients, FSD and QISS showed no significant difference in the number of diagnostic arterial segments (151 [98%] vs. 147 [96%], respectively, P>0.05). The image quality of FSD was higher than that of QISS in the peroneal artery and posterior tibial artery (P<0.05), but no significant difference in the anterior tibial artery (P>0.05). SNR and CNR of FSD were higher than those of QISS (P<0.01), while FSD showed comparable vessel sharpness compared with QISS (P>0.05). The time efficiency of SNR and CNR between FSD and QISS showed no significant difference when taking into account the times for FSD-related scout scans. There was no difference in sensitivity (95% vs. 93%, P>0.05) and negative predictive value (98% vs. 97%, P>0.05) between FSD and QISS for detecting stenosis greater than 50%. However, FSD showed higher specificities (99% vs. 92%, P<0.05) and diagnostic accuracy (98% vs. 92%, P<0.05) compared to QISS. Conclusion Both FSD and QISS had similar high sensitivity and negative predictive value for detecting calf arteries with over 50% stenosis, but FSD showed slightly higher diagnostic specificity and better depiction of arterial lesions due to its isotropic submillimeter spatial resolution. QISS, being an easier to use and less time-consuming technique, could be a method of choice for rapid screening of arterial disease of the lower extremity.
Collapse
Affiliation(s)
- Na Zhang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology of Chinese Academy of Sciences, Shenzhen, China
- Shenzhen Key Laboratory for MRI, Shenzhen Institutes of Advanced Technology of Chinese Academy of Sciences, Shenzhen, China
| | - Liqiu Zou
- Department of Radiology, Peking University Shenzhen Hospital, Shenzhen, China
| | - Yi Huang
- Department of Radiology, Guangzhou Panyu Central Hospital, Guangzhou, China
| | - Dexiang Liu
- Department of Radiology, Guangzhou Panyu Central Hospital, Guangzhou, China
| | - Yukuan Tang
- Department of Radiology, Guangzhou Panyu Central Hospital, Guangzhou, China
| | - Zhaoyang Fan
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States of America
| | - Hanwei Chen
- Department of Radiology, Guangzhou Panyu Central Hospital, Guangzhou, China
- * E-mail: (XL); (HC)
| | - Xin Liu
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology of Chinese Academy of Sciences, Shenzhen, China
- Shenzhen Key Laboratory for MRI, Shenzhen Institutes of Advanced Technology of Chinese Academy of Sciences, Shenzhen, China
- * E-mail: (XL); (HC)
| |
Collapse
|
14
|
Liu X, Fan Z, Zhang N, Yang Q, Feng F, Liu P, Zheng H, Li D. Unenhanced MR angiography of the foot: initial experience of using flow-sensitive dephasing-prepared steady-state free precession in patients with diabetes. Radiology 2014; 272:885-94. [PMID: 24758556 DOI: 10.1148/radiol.14132284] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To assess image quality and diagnostic performance of unenhanced magnetic resonance (MR) angiography with use of flow-sensitive dephasing (FSD)-prepared steady-state free precession (SSFP) of the foot arteries in patients with diabetes. MATERIALS AND METHODS This prospective study was approved by institutional review board. Informed consent was obtained from all subjects. Thirty-two healthy volunteers and 38 diabetic patients who had been scheduled for lower-extremity contrast material-enhanced MR angiography were recruited to undergo unenhanced MR angiography with a 1.5-T MR unit. Image quality and diagnostic accuracy of unenhanced MR angiography in the detection of significant arterial stenosis (≥50%) were assessed by two independent reviewers. Contrast-enhanced MR angiography was used as the reference standard. The difference in the percentage of diagnostic arterial segments at unenhanced MR angiography between healthy volunteers and diabetic patients was evaluated with the McNemar test and generalized estimating equation for correlated data. Signal-to-noise ratio (SNR) and artery-to-muscle contrast-to-noise ratio (CNR) of pedal arteries were measured and compared between the two MR angiography techniques by using the paired t test. RESULTS All subjects successfully underwent unenhanced MR angiography of the foot. Unenhanced MR angiography yielded a high percentage of diagnostic arterial segments in both healthy volunteers (303 of 320 segments, 95%) and patients (341 of 370 segments, 92%), and there was no difference in the percentage between the two populations (P = .195). In patients, the average SNR and CNR at unenhanced MR angiography were higher than those at contrast-enhanced MR angiography (SNR: 90.7 ± 38.1 vs 81.7 ± 34.7, respectively, P = .023; CNR: 85.2 ± 33.2 vs 76.6 ± 33.5, respectively, P = .013). The average sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of unenhanced MR angiography were 88% (35 of 40 segments), 93% (107 of 115 segments), 81% (35 of 43 segments), 96% (107 of 112 segments), and 92% (142 of 155 segments), respectively. Interobserver agreement between the two readers for diagnostic accuracy was good (κ = 0.83). CONCLUSION Unenhanced MR angiography with use of FSD-prepared SSFP allows clear depiction of the foot arterial tree and accurate detection of significant arterial stenosis. The technique has the potential to be a safe and reliable screening tool for the assessment of foot arteries in diabetic patients without the use of gadolinium-based contrast material.
Collapse
Affiliation(s)
- Xin Liu
- From the Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology of Chinese Academy of Sciences, Shenzhen Key Laboratory for MRI, 1068 Xueyuan Ave, Shenzhen, Guangdong 518055, China (X.L., N.Z., H.Z.); Beijing Center for Mathematical and Information Disciplinary Sciences, Beijing, China (X.L., H.Z.); Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, Calif (Z.F., D.L.); Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing, China (Q.Y.); and Department of Radiology, Peking University Shenzhen Hospital, Shenzhen, China (F.F., P.L.)
| | | | | | | | | | | | | | | |
Collapse
|
15
|
Liu X, Zhang N, Fan Z, Feng F, Yang Q, Zheng H, Liu P, Li D. Detection of infragenual arterial disease using non-contrast-enhanced MR angiography in patients with diabetes. J Magn Reson Imaging 2013; 40:1422-9. [PMID: 24925770 DOI: 10.1002/jmri.24477] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2013] [Accepted: 09/24/2013] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To evaluate the diagnostic performance of a newly developed non-contrast-enhanced MR angiography (NCE-MRA) technique using flow-sensitive dephasing (FSD) prepared steady-state free precession (SSFP) for detecting calf arterial disease in patients with diabetes. MATERIALS AND METHODS Forty-five patients with diabetes who underwent routine contrast-enhanced MR angiography (CE-MRA) of lower extremities were recruited for NCE-MRA at the calf on a 1.5 Tesla MR system. Image quality evaluated on a 4-point scale and diagnostic performance for detecting more than 50% arterial stenosis were statistically analyzed, using CE-MRA as the standard of reference. RESULTS A total of 264 calf arterial segments were obtained in the 45 patients with 88 legs. The percentage of diagnostic arterial segments was all 98% for NCE- and CE-MRA. The image quality, SNR, CNR was 3.3, 177, 138, and 3.5, 103, 99, for NCE-MRA and CE-MRA, respectively. The average sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of NCE-MRA were 97%, 96%, 90%, 99%, and 96%, respectively on a per-segment basis and 90%, 84%, 82%, 91%, and 87%, respectively, on a per-patients basis. CONCLUSION The NCE-MRA technique demonstrates adequate image quality in the delineation of calf arteries and consistent diagnostic performance for detecting significant stenosis with CE-MRA in patients with diabetes.
Collapse
Affiliation(s)
- Xin Liu
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology of Chinese Academy of Sciences, Shenzhen Key Laboratory for MRI, Shenzhen, China
| | | | | | | | | | | | | | | |
Collapse
|
16
|
Priest AN, Joubert I, Winterbottom AP, See TC, Graves MJ, Lomas DJ. Initial clinical evaluation of a non-contrast-enhanced MR angiography method in the distal lower extremities. Magn Reson Med 2013; 70:1644-52. [DOI: 10.1002/mrm.24626] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2012] [Revised: 11/29/2012] [Accepted: 12/13/2012] [Indexed: 12/20/2022]
Affiliation(s)
| | - Ilse Joubert
- Department of Radiology; Addenbrooke's Hospital; Cambridge UK
| | | | - Teik Choon See
- Department of Radiology; Addenbrooke's Hospital; Cambridge UK
| | | | | |
Collapse
|
17
|
Akbayrak E, Dinser R, Müller-Ladner U, Tarner IH. Low-field magnetic resonance imaging study on carpal arthritis in systemic sclerosis--low-grade erosive arthritis of carpal bones is an unexpected and frequent disease manifestation. Arthritis Res Ther 2013; 15:R2. [PMID: 23289906 PMCID: PMC3672762 DOI: 10.1186/ar4128] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2012] [Accepted: 01/02/2013] [Indexed: 11/10/2022] Open
Abstract
Introduction The aim of the present study was to assess the prevalence and characteristics of subclinical arthritis of carpal and metacarpophalangeal joints in patients with systemic sclerosis (SSc). Methods Low-field (0.2 T) magnetic resonance imaging (MRI) was performed in consecutive patients with SSc attending our center between January 2010 and March 2011. Results were assessed in a standardized manner using the Rheumatoid Arthritis Magnetic Resonance Imaging Score (RAMRIS) and standardized assessments of all hand joints. Patients with arthritis due to overlap syndromes were excluded. Results Of 38 inpatients and eight outpatients who were screened for inclusion, 30 patients participated in the study and 26 patients could be evaluated. Erosions, bone marrow edema, synovitis, and joint effusions were found in 87%, 37%, 68%, and 58%, respectively, and 24% of patients had additional tenovaginitis. Arthritis affected only a low number of joints per analyzed hand. All bones and joints could be affected, but synovitis and bone marrow edema occurred predominantly in the proximal row of carpal bones, most frequently affecting the lunate bone. The extent of inflammatory changes measured with the RAMRIS correlated significantly with the functional status assessed with the validated German functional score questionnaire Funktionsfragebogen Hannover. Conclusion Low-grade arthritic changes on low-field MRI are frequent in patients with pure SSc. The features of arthritis in SSc differ from rheumatoid arthritis. The distribution, the MRI pattern and the predilection for the lunate bone raise the hypothesis that arthritis in SSc may be caused not only by immunological inflammation but also by ischemic mechanisms.
Collapse
|
18
|
Wheaton AJ, Miyazaki M. Non-contrast enhanced MR angiography: Physical principles. J Magn Reson Imaging 2012; 36:286-304. [DOI: 10.1002/jmri.23641] [Citation(s) in RCA: 104] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
|
19
|
Dimmick SJ, Goh AC, Cauzza E, Steinbach LS, Baumgartner I, Stauffer E, Voegelin E, Anderson SE. Imaging appearances of Buerger's disease complications in the upper and lower limbs. Clin Radiol 2012; 67:1207-11. [PMID: 22784658 DOI: 10.1016/j.crad.2012.04.005] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2011] [Revised: 04/01/2012] [Accepted: 04/11/2012] [Indexed: 10/28/2022]
Abstract
Thromboangiitis obliterans (Buerger's disease) is a rare, non-atherosclerotic, segmental, inflammatory vasculitis that most commonly involves small and medium-sized arteries, veins and nerves of the extremities and affects tobacco smokers between the ages of 25 and 45 years. The manifestations of Buerger's disease can be extremely variable and, therefore, awareness of the condition is important for both general and musculoskeletal radiologists. This paper presents the radiological appearance of the sequelae of Buerger's disease involving the upper and lower limbs.
Collapse
Affiliation(s)
- S J Dimmick
- Department of Radiology, Royal North Shore Hospital, St Leonards New South Wales, Australia.
| | | | | | | | | | | | | | | |
Collapse
|
20
|
Miyazaki M, Akahane M. Non-contrast enhanced MR angiography: established techniques. J Magn Reson Imaging 2012; 35:1-19. [PMID: 22173999 DOI: 10.1002/jmri.22789] [Citation(s) in RCA: 98] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Until recently, time-of-flight (TOF) and phase contrast (PC) were the only non-contrast MR angiography (NC-MRA) techniques practically used in clinical. In the decade, NC-MRA have been gained a revival of an interest among the MR researchers and scientists, in part because of safety concerns related to the possible link between gadolinium-based contrast agents and nephrogenic systemic fibrosis (NSF). This article introduces other established NC-MRA techniques, such as ECG-gated partial Fourier fast spin echo (FSE) and balanced steady-state free precession (bSSFP), both with and without arterial spin labeling. Then, the article focuses on two main applications: peripheral run-off and renal MRA. Recently, both applications have achieved remarkable advancements and have become a viable clinical option as an alternative to contrast-enhanced (CE)-MRA. In addition, developments on the horizon including whole body MRA applications and further advancement at 3 Tesla are discussed.
Collapse
Affiliation(s)
- Mitsue Miyazaki
- Toshiba Medical Research Institute USA, Vernon Hills, Illinois 60061, USA.
| | | |
Collapse
|
21
|
Frerix M, Stegbauer J, Dragun D, Kreuter A, Weiner SM. Ulnar artery occlusion is predictive of digital ulcers in SSc: a duplex sonography study. Rheumatology (Oxford) 2011; 51:735-42. [DOI: 10.1093/rheumatology/ker414] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
22
|
Noncontrast magnetic resonance angiography of the hand: improved arterial conspicuity by multidirectional flow-sensitive dephasing magnetization preparation in 3D balanced steady-state free precession imaging. Invest Radiol 2011; 46:515-23. [PMID: 21487301 DOI: 10.1097/rli.0b013e318217daee] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE : To develop a flow-sensitive dephasing (FSD) preparative scheme to facilitate multidirectional flow-signal suppression in 3-dimensional balanced steady-state free precession imaging and to validate the feasibility of the refined sequence for noncontrast magnetic resonance angiography (NC-MRA) of the hand. MATERIALS AND METHODS : A new FSD preparative scheme was developed that combines 2 conventional FSD modules. Studies using a flow phantom (gadolinium-doped water 15 cm/s) and the hands of 11 healthy volunteers (6 males and 5 females) were performed to compare the proposed FSD scheme with its conventional counterpart with respect to the signal suppression of multidirectional flow. In 9 of the 11 healthy subjects and 2 patients with suspected vasculitis and documented Raynaud phenomenon, respectively, 3-dimensional balanced steady-state free precession imaging coupled with the new FSD scheme was compared with spatial-resolution-matched (0.94 × 0.94 × 0.94 mm) contrast-enhanced magnetic resonance angiography (0.15 mmol/kg gadopentetate dimeglumine) in terms of overall image quality, venous contamination, motion degradation, and arterial conspicuity. RESULTS : The proposed FSD scheme was able to suppress 2-dimensional flow signal in the flow phantom and hands and yielded significantly higher arterial conspicuity scores than the conventional scheme did on NC-MRA at the regions of common digitals and proper digitals. Compared with contrast-enhanced magnetic resonance angiography, the refined NC-MRA technique yielded comparable overall image quality and motion degradation, significantly less venous contamination, and significantly higher arterial conspicuity score at digital arteries. CONCLUSION : The FSD-based NC-MRA technique is improved in the depiction of multidirectional flow by applying a 2-module FSD preparation, which enhances its potential to serve as an alternative magnetic resonance angiography technique for the assessment of hand vascular abnormalities.
Collapse
|
23
|
Fan Z, Zhou X, Bi X, Dharmakumar R, Carr JC, Li D. Determination of the optimal first-order gradient moment for flow-sensitive dephasing magnetization-prepared 3D noncontrast MR angiography. Magn Reson Med 2011; 65:964-72. [PMID: 21413060 DOI: 10.1002/mrm.22847] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2010] [Revised: 12/18/2010] [Accepted: 12/27/2010] [Indexed: 11/10/2022]
Abstract
Flow-sensitive dephasing (FSD) magnetization preparation has been developed for black-blood vessel wall MRI and noncontrast MR angiography. The first-order gradient moment, m(1) , is a measure of the flow-sensitization imparted by an FSD preparative module. Determination of the optimal m(1) for each individual is highly desirable for FSD-prepared MR angiography. This work developed a 2D m(1)-scouting method that evaluates a range of m(1) values for their effectiveness in blood signal suppression in a single scan. The feasibility of using the 2D method to predict blood signal suppression in 3D FSD-prepared imaging was validated on a flow phantom and the popliteal arteries of 5 healthy volunteers. Excellent correlation of the blood signal measurements between the 2D scouting and 3D FSD imaging was obtained. Therefore, the optimal m(1) determined from the 2D m(1)-scouting scan may be directly translated to 3D FSD-prepared imaging. In vivo studies of additional 10 healthy volunteers and 2 patients have demonstrated the proposed method can help significantly improve the signal performance of FSD MR angiography, indicating its potential to enhance diagnostic confidence. Further systematic studies in patients are warranted to evaluate its clinical value.
Collapse
Affiliation(s)
- Zhaoyang Fan
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California 90048, USA
| | | | | | | | | | | |
Collapse
|