1
|
Hu L, Ye L, Pei C, Sun C, Zhang C, Jiang F, He N, Lv W. Enhanced stiffness in peri-cancerous tissue: a marker of poor prognosis in papillary thyroid carcinoma with lymph node metastasis. Oncologist 2024; 29:e1132-e1148. [PMID: 38902966 PMCID: PMC11379648 DOI: 10.1093/oncolo/oyae086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2024] [Accepted: 04/11/2024] [Indexed: 06/22/2024] Open
Abstract
BACKGROUND The prognostic significance of lymph node metastasis (LNM) in papillary thyroid carcinoma (PTC) remains controversial. Notably, there is evidence suggesting an association between tissue stiffness and the aggressiveness of the disease. We therefore aimed to explore the effect of tissue stiffness on LNM-related invasiveness in PTC patients. METHOD A total of 2492 PTC patients from 3 hospitals were divided into an LNM group and a non-LNM group based on their pathological results. The effects of interior lesion stiffness (E) and peri-cancerous tissue stiffness (Eshell) on the LNM-related recurrence rate and mortality in each patient with PTC subgroup were analyzed. The activation of cancer-associated fibroblasts (CAFs) and extracellular matrix component type 1 collagen (COL-I) in the lesion were compared and analyzed across different subgroups. The underlying biological basis of differences in each subgroup was identified using RNA sequencing (RNA-seq) data. RESULTS The Eshell value and Eshell/E in the LNM group were significantly higher than those in the non-LNM group of patients with PTC (Eshell: 72.72 ± 5.63 vs 66.05 ± 4.46; Eshell/E: 1.20 ± 1.72 vs 1.09 ± 1.10, P < .001). When Eshell/E > 1.412 and LNM were both present, the recurrence rate and mortality were significantly increased compared to those of group of patients with LNM (91.67% and 7.29%, respectively). The CAF activation and COL-I content in the Eshell/E+ group were significantly higher than those in the Eshell/E- group (all P < .001), and the RNA-seq results revealed significant extracellular matrix (ECM) remodeling in the LNM-Eshell/E+ group. CONCLUSIONS Stiff peri-cancerous tissue induced CAF activation, COL-I deposition, and ECM remodeling, resulting in a poor prognosis for PTC patients with LNM.
Collapse
Affiliation(s)
- Lei Hu
- Department of Ultrasound, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of People's Republic of China, Hefei, Anhui 230001, People's Republic of China
| | - Lei Ye
- Department of Ultrasound, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of People's Republic of China, Hefei, Anhui 230001, People's Republic of China
| | - Chong Pei
- Department of Respiratory and Critical Care Medicine, The First People's Hospital of Hefei City, The Third Affiliated Hospital of Anhui Medical University, Hefei 230001, People's Republic of China
| | - Chunlei Sun
- Department of Thyroid and Breast Surgery, The First Affiliated Hospital of USTC, University of Science and Technology of People's Republic of China, Hefei, 230001, People's Republic of China
| | - Chaoxue Zhang
- Department of Ultrasound, The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui 230001, People's Republic of China
| | - Fan Jiang
- Department of Ultrasound, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui 230001, People's Republic of China
| | - Nianan He
- Department of Ultrasound, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of People's Republic of China, Hefei, Anhui 230001, People's Republic of China
| | - Weifu Lv
- Department of Radiology, The First Affiliated Hospital of USTC, University of Science and Technology of People's Republic of China, Hefei 230001, People's Republic of China
| |
Collapse
|
2
|
Jia W, Xia S, Jia X, Tang B, Cheng S, Nie M, Guan L, Duan Y, Zhang M, Chen X, Zhang H, Bai B, Jia H, Li N, Yuan C, Cai E, Dong Y, Zhang J, Jia Y, Liu J, Tang Z, Luo T, Zhang X, Zhan W, Zhu Y, Zhou J. Ultrasound Viscosity Imaging in Breast Lesions: A Multicenter Prospective Study. Acad Radiol 2024; 31:3499-3510. [PMID: 38582684 DOI: 10.1016/j.acra.2024.03.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Revised: 02/16/2024] [Accepted: 03/17/2024] [Indexed: 04/08/2024]
Abstract
RATIONALE AND OBJECTIVES To explore and validate the clinical value of ultrasound (US) viscosity imaging in differentiating breast lesions by combining with BI-RADS, and then comparing the diagnostic performances with BI-RADS alone. MATERIALS AND METHODS This multicenter, prospective study enrolled participants with breast lesions from June 2021 to November 2022. A development cohort (DC) and validation cohort (VC) were established. Using histological results as reference standard, the viscosity-related parameter with the highest area under the receiver operating curve (AUC) was selected as the optimal one. Then the original BI-RADS would upgrade or not based on the value of this parameter. Finally, the results were validated in the VC and total cohorts. In the DC, VC and total cohorts, all breast lesions were divided into the large lesion, small lesion and overall groups respectively. RESULTS A total of 639 participants (mean age, 46 years ± 14) with 639 breast lesions (372 benign and 267 malignant lesions) were finally enrolled in this study including 392 participants in the DC and 247 in the VC. In the DC, the optimal viscosity-related parameter in differentiating breast lesions was calculated to be A'-S2-Vmax, with the AUC of 0.88 (95% CI: 0.84, 0.91). Using > 9.97 Pa.s as the cutoff value, the BI-RADS was then modified. The AUC of modified BI-RADS significantly increased from 0.85 (95% CI: 0.81, 0.88) to 0.91 (95% CI: 0.87, 0.93), 0.85 (95% CI: 0.80, 0.89) to 0.90 (95% CI: 0.85, 0.93) and 0.85 (95% CI: 0.82, 0.87) to 0.90 (95% CI: 0.88, 0.92) in the DC, VC and total cohorts respectively (P < .05 for all). CONCLUSION The quantitative viscous parameters evaluated by US viscosity imaging contribute to breast cancer diagnosis when combined with BI-RADS.
Collapse
Affiliation(s)
- WanRu Jia
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No.197 Ruijin 2nd Road, 200025 Shanghai, China; College of Health Science and Technology, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China
| | - ShuJun Xia
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No.197 Ruijin 2nd Road, 200025 Shanghai, China; College of Health Science and Technology, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China
| | - XiaoHong Jia
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No.197 Ruijin 2nd Road, 200025 Shanghai, China
| | - BingHui Tang
- Department of Ultrasound, Nanchang People's Hospital, Nanchang, Jiangxi Province 330000, China
| | - ShuZhen Cheng
- Department of Ultrasound, Nanchang People's Hospital, Nanchang, Jiangxi Province 330000, China
| | - MeiYuan Nie
- Department of Ultrasound, Nanchang People's Hospital, Nanchang, Jiangxi Province 330000, China
| | - Ling Guan
- Department of Ultrasound, Gansu Provincial Cancer Hospital, Lanzhou, Gansu Province, China
| | - Ying Duan
- Department of Ultrasound, Gansu Provincial Cancer Hospital, Lanzhou, Gansu Province, China
| | - MengYan Zhang
- Department of Ultrasound, Gansu Provincial Cancer Hospital, Lanzhou, Gansu Province, China
| | - Xia Chen
- Department of Ultrasound, Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou Province, China
| | - Hui Zhang
- Department of Ultrasound, The First Hospital of Jiaxing, Affiliated Hospital of Jiaxing University, Jiaxing, Zhejiang Province, China
| | - BaoYan Bai
- Department of Ultrasound, Affiliated Hospital of Yan'an University, Yan'an, Shaanxi Province, China
| | - HaiYun Jia
- Department of Ultrasound, Affiliated Hospital of Yan'an University, Yan'an, Shaanxi Province, China
| | - Ning Li
- Department of Ultrasound, Yunnan Kungang Hospital, The Seventh Affiliated Hospital of Dali University, No.2 Ganghenan Road, Anning, Yunnan Province 650330, China
| | - CongCong Yuan
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No.197 Ruijin 2nd Road, 200025 Shanghai, China
| | - EnHeng Cai
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No.197 Ruijin 2nd Road, 200025 Shanghai, China
| | - YiJie Dong
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No.197 Ruijin 2nd Road, 200025 Shanghai, China; College of Health Science and Technology, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China
| | - JingWen Zhang
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No.197 Ruijin 2nd Road, 200025 Shanghai, China
| | - Yi Jia
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No.197 Ruijin 2nd Road, 200025 Shanghai, China
| | - Juan Liu
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No.197 Ruijin 2nd Road, 200025 Shanghai, China
| | - ZhenYun Tang
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No.197 Ruijin 2nd Road, 200025 Shanghai, China
| | - Ting Luo
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No.197 Ruijin 2nd Road, 200025 Shanghai, China
| | - XiaoXiao Zhang
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No.197 Ruijin 2nd Road, 200025 Shanghai, China
| | - WeiWei Zhan
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No.197 Ruijin 2nd Road, 200025 Shanghai, China; College of Health Science and Technology, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China
| | - Ying Zhu
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No.197 Ruijin 2nd Road, 200025 Shanghai, China; College of Health Science and Technology, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China
| | - JianQiao Zhou
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No.197 Ruijin 2nd Road, 200025 Shanghai, China; College of Health Science and Technology, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China.
| |
Collapse
|
3
|
Deeg J, Swoboda M, Egle D, Wieser V, Soleiman A, Ladenhauf V, Galijasevic M, Amort B, Gruber L. Shear-Wave Elastography Gradient Analysis of Newly Diagnosed Breast Tumours: A Critical Analysis. Diagnostics (Basel) 2024; 14:1657. [PMID: 39125533 PMCID: PMC11312263 DOI: 10.3390/diagnostics14151657] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2024] [Revised: 07/24/2024] [Accepted: 07/26/2024] [Indexed: 08/12/2024] Open
Abstract
BACKGROUND A better understanding of the peritumoral stroma changes due to tumour invasion using non-invasive diagnostic methods may improve the differentiation between benign and malignant breast lesions. This study aimed to assess the correlation between breast lesion differentiation and intra- and peritumoral shear-wave elastography (SWE) gradients. METHODS A total of 135 patients with newly diagnosed breast lesions were included. Intratumoral, subsurface, and three consecutive peritumoral SWE value measurements (with three repetitions) were performed. Intratumoral, interface, and peritumoral gradients (Gradient 1 and Gradient 2) were calculated using averaged SWE values. Statistical analysis included descriptive statistics and an ordinary one-way ANOVA to compare overall and individual gradients among Breast Imaging-Reporting and Data System (BI-RADS) 2, 3, and 5 groups. RESULTS Malignant tumours showed higher average SWE velocity values at the tumour centre (BI-RADS 2/3: 4.1 ± 1.8 m/s vs. BI-RADS 5: 4.9 ± 2.0 m/s, p = 0.04) and the first peritumoral area (BI-RADS 2/3: 3.4 ± 1.8 m/s vs. BI-RADS 5: 4.3 ± 1.8 m/s, p = 0.003). No significant difference was found between intratumoral gradients (0.03 ± 0.32 m/s vs. 0.0 ± 0.28 m/s; p > 0.999) or gradients across the tumour-tissue interface (-0.17 ± 0.18 m/s vs. -0.13 ± 0.35 m/s; p = 0.202). However, the first peritumoral gradient (-0.16 ± 0.24 m/s vs. -0.35 ± 0.31 m/s; p < 0.0001) and the second peritumoral gradient (-0.11 ± 0.18 m/s vs. -0.22 ± 0.28 m/s; p = 0.037) were significantly steeper in malignant tumours. The AUC was best for PTG1 (0.7358) and PTG2 (0.7039). A threshold value for peritumoral SWI PT1 above 3.76 m/s and for PTG1 below -0.238 m/s·mm-1 indicated malignancy in 90.6% of cases. CONCLUSIONS Evaluating the peritumoral SWE gradient may improve the diagnostic pre-test probability, as malignant tumours showed a significantly steeper curve of the elasticity values in the peritumoral stroma compared to the linear regression with a relatively flat curve of benign lesions.
Collapse
Affiliation(s)
- Johannes Deeg
- Department of Radiology, Medical University Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria; (J.D.); (V.L.); (M.G.); (B.A.); (L.G.)
| | - Michael Swoboda
- Department of Radiology, Medical University Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria; (J.D.); (V.L.); (M.G.); (B.A.); (L.G.)
| | - Daniel Egle
- Department of Obstetrics and Gynaecology, Medical University Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria; (D.E.); (V.W.)
| | - Verena Wieser
- Department of Obstetrics and Gynaecology, Medical University Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria; (D.E.); (V.W.)
| | - Afschin Soleiman
- Institute for Pathology, INNPath, University Hospital Tirol Kliniken, Anichstraße 35, 6020 Innsbruck, Austria;
| | - Valentin Ladenhauf
- Department of Radiology, Medical University Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria; (J.D.); (V.L.); (M.G.); (B.A.); (L.G.)
| | - Malik Galijasevic
- Department of Radiology, Medical University Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria; (J.D.); (V.L.); (M.G.); (B.A.); (L.G.)
| | - Birgit Amort
- Department of Radiology, Medical University Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria; (J.D.); (V.L.); (M.G.); (B.A.); (L.G.)
| | - Leonhard Gruber
- Department of Radiology, Medical University Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria; (J.D.); (V.L.); (M.G.); (B.A.); (L.G.)
| |
Collapse
|
4
|
Wang J, Cheng H, Li X. Modified TI-RADS Coupled with BRAFV600E Enhances Diagnostic Efficiency in Papillary Thyroid Carcinoma: Prospective Study. Int J Gen Med 2024; 17:3015-3025. [PMID: 39006910 PMCID: PMC11246655 DOI: 10.2147/ijgm.s456820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Accepted: 06/09/2024] [Indexed: 07/16/2024] Open
Abstract
Background Thyroid disorders, relatively common diseases of the endocrine system, have risen gradually in recent years. Early detection and accurate diagnosis of thyroid cancer hold exceptional importance. This study aimed to determine the efficacy of a modified TI-RADS and BRAFV600E mutation testing for thyroid cancer (PTC) diagnosis. Methods Ninety five thyroid nodules (48 benign and 47 malignant) from 81 patients were examined using Kwak Thyroid Imaging Reporting and Data System (TI-RADS) were subjected to shear wave elasticity (SWE), BRAFV600E genotyping and fine needle aspiration (FNA) cytology. Results The modified TI-RADS exhibited superior diagnostic accuracy compared to TI-RADS in differentiating benign nodules from malignant thyroid nodules. Moreover, the AUC of modified TI-RADS in conjunction with BRAFV600E was the highest at 95% CI (0.898-0.992, p=0.003), surpassing other diagnostic methods in enhanced sensitivity and maintaining high specificity. Conclusion The diagnostic efficiency of this combination surpassed that of individual diagnostic methods.
Collapse
Affiliation(s)
- Jing Wang
- Department of Ultrasound, Bishan Hospital of Chongqing, Bishan Hospital of Chongqing Medical University, Chongqing, 402760, People’s Republic of China
| | - Hong Cheng
- Department of Ultrasound, Bishan Hospital of Chongqing, Bishan Hospital of Chongqing Medical University, Chongqing, 402760, People’s Republic of China
| | - Xu Li
- Department of Ultrasound, Bishan Hospital of Chongqing, Bishan Hospital of Chongqing Medical University, Chongqing, 402760, People’s Republic of China
| |
Collapse
|
5
|
Asafu Adjaye Frimpong G, Aboagye E, Owusu-Afriyie O, Bonsu EO, Mahama F, Asante E, Asafu Adjaye Frimpong BG. Shear Wave Elastography in Breast Cancer: Unveiling Correlations With Histopathological Grades and Subtypes. Cureus 2024; 16:e63759. [PMID: 39099972 PMCID: PMC11296557 DOI: 10.7759/cureus.63759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/03/2024] [Indexed: 08/06/2024] Open
Abstract
Objective This study explores the correlation between shear wave elastography (SWE) features and histopathological grades and subtypes in breast cancer, aiming to enhance diagnostic accuracy and personalized treatment strategies. Methods The study retrospectively analyzed 59 consecutive women with breast cancer who underwent breast ultrasound with SWE. SWE parameters and histopathologic information, including histological type and grade, were recorded. Qualitative and quantitative SWE findings were analyzed, and B-mode findings were evaluated. Sociodemographic and clinical factors and B-mode findings were assessed as predictors of elastography stiffness using logistic regression analysis. Results Of the 59 participants diagnosed with breast cancer, invasive ductal carcinoma of no special type (IDC-NST) was predominantly found in 50 (84.7%) cases, followed by invasive medullary carcinoma in 5 (8.5%) cases. The majority of participants belonged to the 50-59 age group, comprising 19 (32.2%) patients. Histopathological grading revealed grade II tumors in 27 (45.8%) cases and grade III tumors in 24 (40.7%) cases. Notably, grade III tumors exhibited higher tissue stiffness compared to grade II tumors. Out of 36 stiff lesions, 30 (83.3%%) were IDC-NST while 3 (8.3%) were invasive medullary carcinoma. A significant association was observed between higher histopathological grade (grade III) and increased tissue stiffness (p < 0.05). Furthermore, among participants with stiff lesions, 21 (58.3%) exhibited color defects while 4 (23.5%) cases with soft lesions also displayed color defects Conclusion The correlation between SWE findings and histopathological grades and subtypes underscores the potential of SWE as a valuable tool for predicting tumor aggressiveness and characterizing specific subtypes. SWE enhances diagnostic accuracy and complements traditional imaging modalities, holding promise for personalized treatment strategies.
Collapse
Affiliation(s)
- George Asafu Adjaye Frimpong
- Radiology, Kwame Nkrumah University of Science and Technology, Kumasi, GHA
- Radiology, Spectra Health Imaging and Interventional Radiology, Kumasi, GHA
| | - Evans Aboagye
- Research and Development, Spectra Health Imaging and Interventional Radiology, Kumasi, GHA
| | - Osei Owusu-Afriyie
- Pathology, Kwame Nkrumah University of Science and Technology, Kumasi, GHA
| | - Ernest O Bonsu
- National Radiotherapy and Nuclear Medicine, Komfo Anokye Teaching Hospital, Kumasi, GHA
| | - Fairuuj Mahama
- Radiology, Spectra Health Imaging and Interventional Radiology, Kumasi, GHA
| | - Emmanuel Asante
- Research and Development, Spectra Health Imaging and Interventional Radiology, Kumasi, GHA
| | | |
Collapse
|
6
|
Marukatat N, Parklug P, Issaragrisil S, Sumanasrethakul C. Shear wave elastography for solid breast masses evaluation: Quantitative measurement of mean elasticity value and elasticity ratio. Eur J Radiol Open 2024; 12:100573. [PMID: 38855720 PMCID: PMC11157203 DOI: 10.1016/j.ejro.2024.100573] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Revised: 05/15/2024] [Accepted: 05/23/2024] [Indexed: 06/11/2024] Open
Abstract
Purpose Shear wave elastography (SWE), an ultrasonographic technique to measure the elasticity of mass lesions to evaluate breast mass. This study aimed to find out the cutoff values identifying breast malignancy using the mean elasticity (E-mean) and elasticity ratio (E-ratio) of breast masses. Methods This retrospective study included women underwent SWE and US-guided biopsy of breast masses. During conventional US, the SWE mode was also performed, determining elasticity measurements, E-mean and E-ratio. Histopathological reports were obtained to identify mass status. The optimal and alternative cutoff values for E-mean and E-ratio to determine malignancy were assessed by receiver operating characteristic (ROC) curve analysis and Youden's index score. Results Among 147 benign and 93 malignant masses, the median of E-means were 26.20 (IQR 15.70-56.60) and 141.60 (IQR 119.80-154.60) kPa and the median E-ratios were 3.11 (IQR 1.83-5.23) and 9.24 (IQR 6.76-12.44), respectively. Using Youden's index, the optimal cutoff values for E-mean and E-ratio were 90.35 and 5.89, with sensitivity of 87.1 % and 82.8 %, specificity of 89.1 % and 83.7 %, positive predictive value (PPV) of 83.5 % and 76.2 %, negative predictive value (NPV) of 91.6 % and 88.5 %, positive likelihood ratio (LR+) of 8.00 and 5.07, and negative likelihood ratio (LR-) of 0.14 and 0.21, respectively. Conclusion This study revealed that SWE is useful in predicting malignancy. With the optimal cutoff values of E-mean and E-ratio at 90.35 kPa and 5.89, the sensitivity was nearly 90 % with E-mean and slightly over 80 % with E-ratio, respectively. These findings could be used in conjunction with conventional US.
Collapse
Affiliation(s)
- N. Marukatat
- Department of Radiology, Faculty of Medicine, Vajira Hospital, Navamindradhiraj University, 681 Samsen Rd., Dusit, Bangkok 10300, Thailand
| | - P. Parklug
- Department of Radiology, Faculty of Medicine, Vajira Hospital, Navamindradhiraj University, 681 Samsen Rd., Dusit, Bangkok 10300, Thailand
| | - S. Issaragrisil
- Department of Radiology, Faculty of Medicine, Vajira Hospital, Navamindradhiraj University, 681 Samsen Rd., Dusit, Bangkok 10300, Thailand
| | - C. Sumanasrethakul
- Department of Urban Medicine, Faculty of Medicine, Vajira Hospital, Navamindradhiraj University, 681 Samsen Rd., Bangkok 10300, Thailand
| |
Collapse
|
7
|
Liu M, Cui N, Sun C, Gong X, Wang B, Yang D, Wang Y. A prospective study on using shear wave elastography to predict the ypT0 stage of rectal cancer after neoadjuvant therapy: a new support for the watch-and-wait approach? Front Mol Biosci 2024; 11:1402498. [PMID: 38737335 PMCID: PMC11082269 DOI: 10.3389/fmolb.2024.1402498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2024] [Accepted: 04/15/2024] [Indexed: 05/14/2024] Open
Abstract
Introduction The diagnostic accuracy of traditional imaging examination in predicting ypT stage of rectal cancer after neoadjuvant therapy is significantly reduced, which would affect patients' subsequent treatment choices. This study aimed to investigate the use of endorectal shear wave elastography (SWE) for diagnosing ypT0 stage of rectal cancer after neoadjuvant chemoradiotherapy (nCRT). Methods Sixty patients with rectal cancer were prospectively recruited in this study. Data on endorectal ultrasound (ERUS) and SWE parameters were collected before nCRT and 6-8 weeks after nCRT. Postoperative pathological results were the gold standard for evaluating the diagnostic accuracy of SWE and ERUS in predicting the ypT0 stage of rectal cancer after nCRT. Receiver operating characteristic (ROC) curve analysis was used to determine the cut-off values of the SWE parameters that best corresponded to the ypT0 stage and analyze the sensitivity, specificity, and accuracy. Results The diagnostic accuracies of using ERUS to predict the ypT and ypT0 stages of rectal cancer after nCRT were 58.1% (18/31) and 64.3% (9/14), respectively. The ROC curve was constructed with the lesion's Emean, Emean corrected (EC), Emean difference (ED), Emean corrected differencede (ECD), Emean descendding rate (EDR) and Emean corrected descendding rate (ECDR) values after nCRT, the cut-off values of diagnosing the ypT0 stage were 64.40 kPa, 55.45 kPa, 72.55 kPa, 73.75 kPa, 50.15%, and 55.93%, respectively; the area under the curve (AUC) for diagnosing the ypT0 stage was 0.924, 0.933, 0.748, 0.729, 0.857 and 0.861, respectively. The EC value showed the best diagnostic performance. Conclusion SWE could improve the accuracy of conventional ERUS in diagnosing the ypT0 stage of rectal cancer after nCRT. It is expected to become a new method to help predict pathological complete responses in clinical practice and provide new evidence for the watch-and-wait approach.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Yong Wang
- Department of Ultrasound, National Cancer Center, National Clinical Research Center for Cancer, Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|
8
|
Niu Q, Zhao L, Wang R, Du L, Shi Q, Jia C, Li G, Jin L, Li F. Predictive value of contrast-enhanced ultrasonography and ultrasound elastography for management of BI-RADS category 4 nonpalpable breast masses. Eur J Radiol 2024; 173:111391. [PMID: 38422608 DOI: 10.1016/j.ejrad.2024.111391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Revised: 02/07/2024] [Accepted: 02/21/2024] [Indexed: 03/02/2024]
Abstract
PURPOSE The objective of this study was to investigate the independent risk factors and associated predictive values of contrast-enhanced ultrasound (CEUS), shear wave elastography (SWE), and strain elastography (SE) for high-risk lesions (HRL) and malignant tumors (MT) among nonpalpable breast masses classified as BI-RADS category 4 on conventional ultrasound. METHODS This prospective study involved consecutively admitted patients with breast tumors from January 2018, aiming to explore the management of BI-RADS category 4 breast tumors using CEUS and elastography. We conducted a retrospective review of patient data, focusing on those with a history of a nonpalpable mass as the primary complaint. Pathologic findings after surgical resection served as the gold standard. The CEUS arterial-phase indices were analyzed using contrast agent arrival-time parametric imaging processing mode, while quantitative and qualitative indices were examined on ES images. Independent risk factors were identified through binary logistic regression multifactorial analysis. The predictive efficacy of different modalities was compared using a receiver operating characteristics curve. Subsequently, a nomogram for predicting the risk of HRL/MT was established based on a multifactorial logistic regression model. RESULTS A total of 146 breast masses from 146 patients were included, comprising 80 benign tumors, 12 HRLs, and 54 MTs based on the final pathology. There was no significant difference in pathologic size between the benign and HRL/MT groups [8.00(6.25,10.00) vs. 9.00(6.00,10.00), P = 0.506]. The diagnostic efficacy of US plus CEUS exceeded that of US plus SWE/SE for BI-RADS 4 nonpalpable masses, with an AUC of 0.954 compared to 0.798/0.741 (P < 0.001). Further stratified analysis revealed a more pronounced improvement for reclassification of BI-RADS 4a masses (AUC: 0.943 vs. 0.762/0.675, P < 0.001) than BI-RADS 4b (AUC:0.950 vs. 0.885/0.796, P>0.05) with the assistance of CEUS than SWE/SE. Employing downgrade CEUS strategies resulted in negative predictive values ranging from 95.2 % to 100.0 % for BI-RADS 4a and 4b masses. Conversely, using upgrade nomogram strategies, which included the independent predictive risk factors of irregular enhanced shape, poor defined enhanced margin, earlier enhanced time, increased surrounding vessels, and presence of contrast agent retention, the diagnostic performance achieved an AUC of 0.947 with good calibration. CONCLUSION After investigating the potential of CEUS and ES in improving risk assessment and diagnostic accuracy for nonpalpable BI-RADS category 4 breast masses, it is evident that CEUS has a more significant impact on enhancing classification compared to ES, particularly for BI-RADS 4a subgroup masses. This finding suggests that CEUS may offer greater benefits in improving risk assessment and diagnostic accuracy for this specific subgroup of breast masses.
Collapse
Affiliation(s)
- Qinghua Niu
- Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Lei Zhao
- Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Ruitao Wang
- Department of Surgery, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Lianfang Du
- Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Qiusheng Shi
- Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Chao Jia
- Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Gang Li
- Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Lifang Jin
- Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
| | - Fan Li
- Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
| |
Collapse
|
9
|
Yao J, Zhou W, Zhu Y, Zhou J, Chen X, Zhan W. Predictive nomogram using multimodal ultrasonographic features for axillary lymph node metastasis in early‑stage invasive breast cancer. Oncol Lett 2024; 27:95. [PMID: 38288042 PMCID: PMC10823315 DOI: 10.3892/ol.2024.14228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Accepted: 12/19/2023] [Indexed: 01/31/2024] Open
Abstract
Axillary lymph node (ALN) status is a key prognostic factor in patients with early-stage invasive breast cancer (IBC). The present study aimed to develop and validate a nomogram based on multimodal ultrasonographic (MMUS) features for early prediction of axillary lymph node metastasis (ALNM). A total of 342 patients with early-stage IBC (240 in the training cohort and 102 in the validation cohort) who underwent preoperative conventional ultrasound (US), strain elastography, shear wave elastography and contrast-enhanced US examination were included between August 2021 and March 2022. Pathological ALN status was used as the reference standard. The clinicopathological factors and MMUS features were analyzed with uni- and multivariate logistic regression to construct a clinicopathological and conventional US model and a MMUS-based nomogram. The MMUS nomogram was validated with respect to discrimination, calibration, reclassification and clinical usefulness. US features of tumor size, echogenicity, stiff rim sign, perfusion defect, radial vessel and US Breast Imaging Reporting and Data System category 5 were independent risk predictors for ALNM. MMUS nomogram based on these factors demonstrated an improved calibration and favorable performance [area under the receiver operator characteristic curve (AUC), 0.927 and 0.922 in the training and validation cohorts, respectively] compared with the clinicopathological model (AUC, 0.681 and 0.670, respectively), US-depicted ALN status (AUC, 0.710 and 0.716, respectively) and the conventional US model (AUC, 0.867 and 0.894, respectively). MMUS nomogram improved the reclassification ability of the conventional US model for ALNM prediction (net reclassification improvement, 0.296 and 0.288 in the training and validation cohorts, respectively; both P<0.001). Taken together, the findings of the present study suggested that the MMUS nomogram may be a promising, non-invasive and reliable approach for predicting ALNM.
Collapse
Affiliation(s)
- Jiejie Yao
- Department of Ultrasound, Ruijin Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200025, P.R. China
| | - Wei Zhou
- Department of Ultrasound, Ruijin Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200025, P.R. China
| | - Ying Zhu
- Department of Ultrasound, Ruijin Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200025, P.R. China
| | - Jianqiao Zhou
- Department of Ultrasound, Ruijin Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200025, P.R. China
| | - Xiaosong Chen
- Comprehensive Breast Health Center, Ruijin Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200025, P.R. China
| | - Weiwei Zhan
- Department of Ultrasound, Ruijin Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200025, P.R. China
| |
Collapse
|
10
|
Keçeli M, Akyürek N. Early breast development in girls: the power of greyscale sonography and sonoelastography. Br J Radiol 2024; 97:594-599. [PMID: 38331404 PMCID: PMC11027302 DOI: 10.1093/bjr/tqae020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 11/03/2023] [Accepted: 01/16/2024] [Indexed: 02/10/2024] Open
Abstract
OBJECTIVE Accurate distinction between central pubertal precociousness (PP) and premature thelarche (PT) is important to guide treatment. Both greyscale ultrasonography (US) and sonoelastography can be used to examine breast tissue. The aim of this study is to investigate the performance of breast US and strain elastographic (SE) in the diagnosis of increased breast volume in girls. METHODS Sixty-three girls with breast development up to 8 years of age and diagnosed with PP and PT were included in the prospective study. Basal luteinizing hormone (LH), follicle-stimulating hormone (FSH), and estradiol (E2) values were obtained. Each bud was considered as a unit in US. Mediolateral (ML) and anteroposterior diameters (AP) were measured, and US grading was performed. Breast SE was examined, and strain index (SI) was calculated. US and laboratory findings were compared. RESULTS Of the 121 buds examined, 39 (32.2%) were with PP (6.97 ± 2.44 years) and 82 (67.8%) were with PT (6.51 ± 2.52 years). Diameters were correlated with bone age, LH, FSH, and US grade. The mean AP showed a moderate difference in favour of PP between the groups (P < .06). The mean ML was higher in PP (P < .01). There was a difference in mean SI values (P < .004). Sensitivity and specificity were 71% and 61% for ML and 72% and 56% for SI, respectively. CONCLUSION Both ML and US grading may help discriminate PP from PT. The role of sonoelastography requires further investigation. ADVANCES IN KNOWLEDGE Ultrasound and SE show significant differences between PP and PT, but these are not sufficiently reliable to be of clinical use. The contribution of sonoelastography requires further study before it can be recommended. However, SI of breast tissue can be helpful in distinguishing PP and PT from other causes of early increase in breast volume.
Collapse
Affiliation(s)
- Merter Keçeli
- Ankara City Hospital Pediatric Radiology Department, Health Sciences University, Ankara 06800, Turkey
| | | |
Collapse
|
11
|
Zhang W, Wang S, Wang Y, Sun J, Wei H, Xue W, Dong X, Wang X. Ultrasound-based radiomics nomogram for predicting axillary lymph node metastasis in early-stage breast cancer. LA RADIOLOGIA MEDICA 2024; 129:211-221. [PMID: 38280058 DOI: 10.1007/s11547-024-01768-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Accepted: 01/03/2024] [Indexed: 01/29/2024]
Abstract
PURPOSE We aimed at assessing the predictive ability of ultrasound-based radiomics combined with clinical characteristics for axillary lymph node (ALN) status in early-stage breast cancer patients and to compare performance in different peritumoral regions. MATERIALS AND METHODS A total of 755 patients (527 in the primary cohort and 228 in the external validation cohort) were enrolled in this study. Ultrasound images for all patients were acquired and radiomics analysis performed for intratumoral and different peritumoral regions. The MRMR and LASSO regression analyses were performed on extracted features from the primary cohort to construct a radiomics signature formula combined with clinical characteristics. Pearson's coefficient and the variance inflation factor (VIF) were performed to check the correlation and the multicollinearity among the final predictors. The best performing model was selected to develop a nomogram, which was established by performing binary logistic regression and acquiring cut-off values based on the corresponding nomogram scores of the masses. RESULTS Among all the radiomics models, the "Mass + Margin3mm" model exhibited the best performance. The areas under the curves (AUC) of the nomogram in the primary and external validation cohorts were 0.906 (95% confidence intervals [CI] 0.882-0.930) and 0.922 (95% CI 0.894-0.960), respectively. They both showed good calibrations. The nomogram exhibited a good ability to discriminate between positive and negative lymph nodes (AUC: 0.853 (95% CI 0.816-0.889) in primary cohort, 0.870 (95% CI 0.818-0.922) in validation cohort), and between low-volume and high-volume lymph nodes (AUC: 0.832 (95% CI 0.781-0.884) in primary cohort, 0.911 (95% CI 0.858-0.964) in validation cohort). CONCLUSIONS The established nomogram is a prospective clinical prediction tool for non-invasive assessment of ALN status. It has the ability to enhance the accuracy of early-stage breast cancer treatment.
Collapse
Affiliation(s)
- Wuyue Zhang
- In-Patient Ultrasound Department, The Second Affiliated Hospital of Harbin Medical University, 246 Xuefu Road, NanGang District, Harbin, 150086, China
| | - Siying Wang
- In-Patient Ultrasound Department, The Second Affiliated Hospital of Harbin Medical University, 246 Xuefu Road, NanGang District, Harbin, 150086, China
| | - Yichun Wang
- In-Patient Ultrasound Department, The Second Affiliated Hospital of Harbin Medical University, 246 Xuefu Road, NanGang District, Harbin, 150086, China
| | - Jiawei Sun
- In-Patient Ultrasound Department, The Second Affiliated Hospital of Harbin Medical University, 246 Xuefu Road, NanGang District, Harbin, 150086, China
| | - Hong Wei
- In-Patient Ultrasound Department, The Second Affiliated Hospital of Harbin Medical University, 246 Xuefu Road, NanGang District, Harbin, 150086, China
| | - Weili Xue
- In-Patient Ultrasound Department, The Second Affiliated Hospital of Harbin Medical University, 246 Xuefu Road, NanGang District, Harbin, 150086, China
| | - Xueying Dong
- In-Patient Ultrasound Department, The Second Affiliated Hospital of Harbin Medical University, 246 Xuefu Road, NanGang District, Harbin, 150086, China
| | - Xiaolei Wang
- In-Patient Ultrasound Department, The Second Affiliated Hospital of Harbin Medical University, 246 Xuefu Road, NanGang District, Harbin, 150086, China.
| |
Collapse
|
12
|
Wang Y, Nie F, Liu T, Zhu Y, Jia Y, Li N, Wu R. The value of Demetics ultrasound-assisted diagnosis system in diagnosis of breast lesions and in assessment Ki-67 status of breast cancer. JOURNAL OF CLINICAL ULTRASOUND : JCU 2024; 52:112-123. [PMID: 37930047 DOI: 10.1002/jcu.23599] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Revised: 10/08/2023] [Accepted: 10/16/2023] [Indexed: 11/07/2023]
Abstract
PURPOSE This study aims to explore the diagnostic efficiency of the Demetics for breast lesions and assessment of Ki-67 status. MATERIAL This retrospective study included 291 patients. Three combined methods (method 1: upgraded BI-RADS when Demetics classified the breast lesion as malignant; method 2: downgraded BI-RADS when Demetics classified the breast lesion as benign; method 3: BI-RADS was upgraded or downgraded according to Demetrics' diagnosis) were used to compare the diagnostic efficiency of two radiologists with different seniority before and after using Demetics. The correlation between the visual heatmap by Demetics and the Ki-67 expression level of breast cancer was explored. RESULTS The sensitivity, specificity, and area under curve (AUC) of diagnosis by Demetics, junior radiologist and senior radiologist were 89.5%, 83.1%, 0.863; 76.9%, 82.4%, 0.797 and 81.1%, 89.9%, 0.855, respectively. Method 1 was the best for senior radiologist, which increased AUC from 0.855 to 0.884. For junior radiologist, Method 3 was the best method, improving sensitivity (88.8% vs. 76.9%) and specificity (87.2% vs. 82.4%). Demetics paid more attention to the peripheral area of breast cancer with high expression of Ki-67. CONCLUSION Demetics has shown good diagnostic efficiency in the assisted diagnosis of breast lesions and is expected to further distinguish Ki-67 status of breast cancer.
Collapse
Affiliation(s)
- Yao Wang
- Lanzhou University Second Hospital Department of Ultrasound, Lanzhou, China
| | - Fang Nie
- Lanzhou University Second Hospital Department of Ultrasound, Lanzhou, China
| | - Ting Liu
- Lanzhou University Second Hospital Department of Ultrasound, Lanzhou, China
| | - Yangyang Zhu
- Lanzhou University Second Hospital Department of Ultrasound, Lanzhou, China
| | - Yingying Jia
- Lanzhou University Second Hospital Department of Ultrasound, Lanzhou, China
| | - Nana Li
- Lanzhou University Second Hospital Department of Ultrasound, Lanzhou, China
| | - Ruichao Wu
- Lanzhou University School of Information Science and Engineering, Lanzhou, China
| |
Collapse
|
13
|
Yi AJ, Yang WW, Cui XW, Dietrich CF, Wang B. The value of quantitative and a new qualitative color pattern shear wave elastography for the differentiation of ACR TI-RADS 4 or 5 category thyroid nodules measuring ≤10 mm. Front Endocrinol (Lausanne) 2024; 14:1275256. [PMID: 38260152 PMCID: PMC10800972 DOI: 10.3389/fendo.2023.1275256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Accepted: 12/12/2023] [Indexed: 01/24/2024] Open
Abstract
Objective This study aims to evaluate the diagnostic performance of quantitative shear wave elastography (SWE) and a new qualitative color pattern SWE for the differentiation of benign and malignant American College of Radiology Thyroid Imaging, Reporting, and Data System (ACR TI-RADS) 4 or 5 category thyroid nodules measuring ≤10 mm. Materials and methods From May 2020 to July 2022, a total of 237 patients with 270 thyroid nodules were enrolled, and conventional ultrasound and SWE examinations were performed for each patient. Each ACR TI-RADS 4 or 5 category thyroid nodule measuring ≤10 mm was evaluated by quantitative SWE and a new qualitative color pattern SWE. The diagnostic performance of quantitative SWE parameters, the new qualitative color pattern SWE, and the combination of SWE with ACR TI-RADS, respectively, for the differentiation of benign and malignant ACR TI-RADS 4 or 5 category thyroid nodules measuring ≤10 mm was evaluated and compared. Results Among 270 thyroid nodules in 237 patients, 72 (26.67%) thyroid nodules were benign and 198 (73.33%) thyroid nodules were malignant. The qualitative color pattern SWE showed better diagnostic performance than the quantitative SWE parameters. When combining the qualitative color pattern SWE with ACR TI-RADS scores, with the optimal cutoff value of the total points ≥8, the thyroid nodules were considered malignant. The sensitivity, specificity, accuracy, and AUC were 89.90%, 56.94%, 81.11%, and 0.820 (95% CI: 0.768-0.864), respectively. Compared with using qualitative color pattern SWE alone, the combination of qualitative color pattern SWE and ACR TI-RADS had better diagnostic performance, which was significantly different (p < 0.05). Conclusion The combination of qualitative SWE color patterns and ACR TI-RADS had high sensitivity and accuracy, which might be a convenient and useful method to differentiate benign and malignant ACR TI-RADS 4 or 5 category thyroid nodules measuring ≤10 mm. It would be helpful for the management of thyroid nodules and improving prognosis.
Collapse
Affiliation(s)
- Ai-jiao Yi
- Department of medical ultrasound, Yueyang Central Hospital, Yueyang, China
| | - Wei-Wei Yang
- Department of medical ultrasound, Yueyang Central Hospital, Yueyang, China
| | - Xin-Wu Cui
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Christoph F. Dietrich
- Department Allgemeine Innere Medizin, Kliniken Hirslanden Beau Site, Salem und Permanence, Bern, Switzerland
| | - Bin Wang
- Department of medical ultrasound, Yueyang Central Hospital, Yueyang, China
| |
Collapse
|
14
|
Mierke CT. Extracellular Matrix Cues Regulate Mechanosensing and Mechanotransduction of Cancer Cells. Cells 2024; 13:96. [PMID: 38201302 PMCID: PMC10777970 DOI: 10.3390/cells13010096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2023] [Revised: 12/29/2023] [Accepted: 01/01/2024] [Indexed: 01/12/2024] Open
Abstract
Extracellular biophysical properties have particular implications for a wide spectrum of cellular behaviors and functions, including growth, motility, differentiation, apoptosis, gene expression, cell-matrix and cell-cell adhesion, and signal transduction including mechanotransduction. Cells not only react to unambiguously mechanical cues from the extracellular matrix (ECM), but can occasionally manipulate the mechanical features of the matrix in parallel with biological characteristics, thus interfering with downstream matrix-based cues in both physiological and pathological processes. Bidirectional interactions between cells and (bio)materials in vitro can alter cell phenotype and mechanotransduction, as well as ECM structure, intentionally or unintentionally. Interactions between cell and matrix mechanics in vivo are of particular importance in a variety of diseases, including primarily cancer. Stiffness values between normal and cancerous tissue can range between 500 Pa (soft) and 48 kPa (stiff), respectively. Even the shear flow can increase from 0.1-1 dyn/cm2 (normal tissue) to 1-10 dyn/cm2 (cancerous tissue). There are currently many new areas of activity in tumor research on various biological length scales, which are highlighted in this review. Moreover, the complexity of interactions between ECM and cancer cells is reduced to common features of different tumors and the characteristics are highlighted to identify the main pathways of interaction. This all contributes to the standardization of mechanotransduction models and approaches, which, ultimately, increases the understanding of the complex interaction. Finally, both the in vitro and in vivo effects of this mechanics-biology pairing have key insights and implications for clinical practice in tumor treatment and, consequently, clinical translation.
Collapse
Affiliation(s)
- Claudia Tanja Mierke
- Biological Physics Division, Peter Debye Institute of Soft Matter Physics, Faculty of Physics and Earth Science, Leipzig University, Linnéstraße 5, 04103 Leipzig, Germany
| |
Collapse
|
15
|
Wen P, Liu L, Pan L, Li X. Evaluating diagnostic significance: The utilization of elastography and contrast-enhanced ultrasound for differential diagnosis in breast lesions. Clin Hemorheol Microcirc 2024; 88:81-95. [PMID: 38758994 DOI: 10.3233/ch-242216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/19/2024]
Abstract
OBJECTIVE The primary aim of this study is to assess the diagnostic efficacy of elastography and contrast-enhanced ultrasound (CEUS) in the identification of breast lesions subsequent to the optimization and correction of the BI-RADS category 4 classification obtained through conventional ultrasound. The objective is to augment both the specificity and accuracy of breast lesion diagnosis, thereby establishing a reliable framework for reducing unnecessary biopsies in clinical settings. METHODS A cohort comprising 50 cases of breast lesions classified under BI-RADS category 4 was collected during the period from November 2022 and November 2023. These cases were examined utilizing strain elastography (SE), shear wave elastography (SWE), and CEUS. Novel scoring methodologies for ultrasonic elastography (UE) and CEUS were formulated for this investigation. Subsequently, the developed UE and CEUS scoring systems were used to refine and optimize the conventional BI-RADS classification, either in isolation or in conjunction. Based on the revised classification, the benign group was classified as category 3 and the suspected malignant group was classified as category 4a and above, with pathological results serving as the definitive reference standard. The diagnostic efficacy of the optimized UE and CEUS, both independently and in combination, was meticulously scrutinized and compared using receiver operating characteristic (ROC) curve analysis, with pathological findings as the reference standard. RESULTS Within the study group, malignancy manifested in 11 cases. Prior to the implementation of the optimization criteria, 78% (39 out of 50) of patients underwent biopsies deemed unnecessary. Following the application of optimization criteria, specifically a threshold of≥8.5 points for the UE scoring method and≥6.5 points for the CEUS scoring method, the incidence of unnecessary biopsies diminished significantly. Reduction rates were observed at 53.8% (21 out of 39) with the UE protocol, 56.4% (22 out of 39) with the CEUS protocol, and 89.7% (35 out of 39) with the combined UE and CEUS optimization protocols. CONCLUSION The diagnostic efficacy of conventional ultrasound BI-RADS category 4 classification for breast lesions is enhanced following optimized correction using UE and CEUS, either independently or in conjunction. The application of the combined protocol demonstrates a notable reduction in the incidence of unnecessary biopsies.
Collapse
Affiliation(s)
- Peng Wen
- Department of Ultrasound, Jilin Province People's Hospital, Changchun, Jilin, China
| | - Lei Liu
- Department of Ultrasound, The First Hospital of Jilin University, Changchun, Jilin, China
| | - Lili Pan
- Department of Ultrasound, Jilin Province People's Hospital, Changchun, Jilin, China
| | - Xiukun Li
- Department of Ultrasound, Jilin Province People's Hospital, Changchun, Jilin, China
| |
Collapse
|
16
|
Gu Y, Chen Q, Yin H, Zeng M, Gao S, Wang X. Cancer-associated fibroblasts in neoadjuvant setting for solid cancers. Crit Rev Oncol Hematol 2024; 193:104226. [PMID: 38056580 DOI: 10.1016/j.critrevonc.2023.104226] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 11/15/2023] [Accepted: 11/30/2023] [Indexed: 12/08/2023] Open
Abstract
Therapeutic approaches for cancer have become increasingly diverse in recent times. A comprehensive understanding of the tumor microenvironment (TME) holds great potential for enhancing the precision of tumor therapies. Neoadjuvant therapy offers the possibility of alleviating patient symptoms and improving overall quality of life. Additionally, it may facilitate the reduction of inoperable tumors and prevent potential preoperative micrometastases. Within the TME, cancer-associated fibroblasts (CAFs) play a prominent role as they generate various elements that contribute to tumor progression. Particularly, extracellular matrix (ECM) produced by CAFs prevents immune cell infiltration into the TME, hampers drug penetration, and diminishes therapeutic efficacy. Therefore, this review provides a summary of the heterogeneity and interactions of CAFs within the TME, with a specific focus on the influence of neoadjuvant therapy on the microenvironment, particularly CAFs. Finally, we propose several potential and promising therapeutic strategies targeting CAFs, which may efficiently eliminate CAFs to decrease stroma density and impair their functions.
Collapse
Affiliation(s)
- Yanan Gu
- Department of Radiology, Zhongshan Hospital and Shanghai Institute of Medical Imaging, Fudan University, Shanghai 200032, China; Department of Interventional Radiology, Zhongshan Hospital Fudan University Shanghai, 200032, China
| | - Qiangda Chen
- Department of Pancreatic Surgery, Zhongshan Hospital Fudan University, Shanghai 200032, China; Cancer Center, Zhongshan Hospital, Fudan University, Shanghai 200032, China
| | - Hanlin Yin
- Department of Pancreatic Surgery, Zhongshan Hospital Fudan University, Shanghai 200032, China; Cancer Center, Zhongshan Hospital, Fudan University, Shanghai 200032, China
| | - Mengsu Zeng
- Department of Radiology, Zhongshan Hospital and Shanghai Institute of Medical Imaging, Fudan University, Shanghai 200032, China
| | - Shanshan Gao
- Department of Radiology, Zhongshan Hospital and Shanghai Institute of Medical Imaging, Fudan University, Shanghai 200032, China.
| | - Xiaolin Wang
- Department of Radiology, Zhongshan Hospital and Shanghai Institute of Medical Imaging, Fudan University, Shanghai 200032, China; Department of Interventional Radiology, Zhongshan Hospital Fudan University Shanghai, 200032, China.
| |
Collapse
|
17
|
Gruber L, Deeg J, Egle D, Soleiman A, Ladenhauf V, Luger A, Amort B, Daniaux M. Peritumoural Strain Elastography of Newly Diagnosed Breast Tumours: Does Maximum Peritumoural Halo Depth Correlate with Tumour Differentiation and Grade? Diagnostics (Basel) 2023; 13:2064. [PMID: 37370959 DOI: 10.3390/diagnostics13122064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Revised: 06/05/2023] [Accepted: 06/07/2023] [Indexed: 06/29/2023] Open
Abstract
To evaluate the diagnostic utility of the maximum ultrasound strain elastography (SE) halo depth in newly diagnosed and histologically confirmed breast lesions, a retrospective study approval was granted by the local Ethical Review Board. Overall, the maximum strain elastography peritumoural halos (SEPHmax)-the maximum distance between the SE stiffening area and the B-mode lesion size-in 428 cases with newly diagnosed breast lesions were retrospectively analysed alongside patient age, affected quadrant, tumour echogenicity, size, acoustic shadowing, and vascularity. Statistical analysis included an ordinary one-way ANOVA to compare the SEPHmax between BI-RADS 2, 3, and 5 groups and between tumour grades 1, 2, and 3. A binary regression analysis was used to determine the correlation between tumour malignancy and the above-mentioned demographic and imaging factors. SEPHmax was significantly higher in BI-RADS 5 tumours (5.5 ± 3.9 mm) compared to BI-RADS 3 (0.9 ± 1.7 mm, p < 0.0001) and 2 (0.6 ± 1.4 mm, p < 0.0001). The receiver operating characteristic area under the curve was 0.933 for the detection of BI-RADS 5 lesions. Furthermore, tumour grades 2 (5.6 ± 3.6 mm, p = 0.001) and 3 (6.8 ± 4.2 mm, p < 0.0001) exhibited significantly higher SEPHmax than grade 1 tumours (4.0 ± 3.9 mm). Similarly, St. Gallen Ki67-stratified low-risk (p = 0.005) and intermediate-risk (p = 0.013) tumours showed smaller SEPHmax than high-risk tumours. Multivariate analysis revealed a significant correlation between malignant differentiation and SEPHmax (standardized regression coefficient 3.17 [95% confidence interval (CI) 2.42-3.92], p < 0.0001), low tumour echogenicity (1.68 [95% CI 0.41-3.00], p = 0.03), and higher patient age (0.89 [95% CI 0.52-1.26], p < 0.0001). High SEPHmax is a strong predictor for tumour malignancy and a higher tumour grade and can be used to improve tumour characterisation before histopathological evaluation. It may also enable radiologists to identify lesions warranting observation rather than immediate biopsy.
Collapse
Affiliation(s)
- Leonhard Gruber
- Department of Radiology, Medical University Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria
| | - Johannes Deeg
- Department of Radiology, Medical University Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria
| | - Daniel Egle
- Department of Obstetrics and Gynaecology, Medical University Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria
| | - Afschin Soleiman
- Institute for Pathology, INNPath, University Hospital Tirol Kliniken, Anichstraße 35, 6020 Innsbruck, Austria
| | - Valentin Ladenhauf
- Department of Radiology, Medical University Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria
| | - Anna Luger
- Department of Radiology, Medical University Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria
| | - Birgit Amort
- Department of Radiology, Medical University Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria
| | - Martin Daniaux
- Department of Radiology, Medical University Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria
| |
Collapse
|
18
|
Duan H, Zhang J, Zhang G, Zhu X, Wang W. An improved nomogram including elastography for the prediction of non-sentinel lymph node metastasis in breast cancer patients with 1 or 2 sentinel lymph node metastases. Front Oncol 2023; 13:1196592. [PMID: 37342193 PMCID: PMC10277680 DOI: 10.3389/fonc.2023.1196592] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Accepted: 05/23/2023] [Indexed: 06/22/2023] Open
Abstract
Background The rate of breast-conserving surgery is very low in China, compared with that in developed countries; most breast cancer patients receive mastectomy. It is great important to explore the possibility of omitting axillary lymph node dissection (ALND) in early-stage breast cancer patients with 1 or 2 positive sentinel lymph nodes (SLNs) in China. The aim of this study was to develop a nomogram based on elastography for the prediction of the risk of non-SLN (NSLN) metastasis in early-stage breast cancer patients with 1 or 2 positive SLNs. Methods A total of 601 breast cancer patients were initially recruited. According to the inclusion and exclusion criteria, 118 early-stage breast cancer patients with 1 or 2 positive SLNs were finally enrolled and were assigned to the training cohort (n=82) and the validation cohort (n=36), respectively. In the training cohort, the independent predictors were screened by logistic regression analysis and then were used to conducted the nomogram for the prediction of NSLN metastasis in early-stage breast cancer patients with 1 or 2 positive SLNs. The calibration curves, concordance index (C-index), the area under the receiver operating characteristic (ROC) curve (AUC), and Decision curve analysis (DCA) were used to verified the performance of the nomogram. Results The multivariable analysis showed that the enrolled patients with positive HER2 expression (OR=6.179, P=0.013), Ki67≥14% (OR=8.976, P=0.015), larger lesion size (OR=1.038, P=0.045), and higher Emean (OR=2.237, P=0.006) were observed to be the independent factors of NSLN metastasis. Based on the above four independent predictors, a nomogram was conducted to predict the risk of the NSLN metastasis in early-stage breast cancer patients with 1 or 2 positive SLNs. The nomogram showed good discrimination in the prediction of NSLN metastasis, with bias-corrected C-index of 0.855 (95% CI, 0.754-0.956) and 0.853 (95% CI, 0.724-0.983) in the training and validation cohorts, respectively. Furthermore, the AUC was 0.877 (95%CI: 0.776- 0.978) and 0.861 (95%CI: 0.732-0.991), respectively, indicating a good performance of the nomogram. The calibration curve suggested a satisfactory agreement between the predictive and actual risk in both the training (χ2 = 11.484, P=0.176, HL test) and validation (χ2 = 6.247, p = 0.620, HL test) cohorts, and the obvious clinical nets were revealed by DCA. Conclusions We conducted a satisfactory nomogram model to evaluate the risk of NSLN metastasis in early-stage breast cancer patients with 1 or 2 SLN metastases. This model could be considered as an ancillary tool to help such patients to be selectively exempted from ALND.
Collapse
Affiliation(s)
- Hongtao Duan
- Department of Ultrasound, Wuxi Huishan District People’s Hospital, Wuxi, Jiangsu, China
| | - Jiawei Zhang
- Department of Ultrasound, Wuxi Huishan District People’s Hospital, Wuxi, Jiangsu, China
| | - Guanxin Zhang
- Department of Ultrasound, Wuxi Huishan District People’s Hospital, Wuxi, Jiangsu, China
| | - Xingmeng Zhu
- Department of Ultrasound, Wuxi Huishan District People’s Hospital, Wuxi, Jiangsu, China
| | - Wenjia Wang
- Department of Ultrasound, Hulunbuir People’s Hospital, Hulunbuir, China
| |
Collapse
|
19
|
Wang S, Wen W, Zhao H, Liu J, Wan X, Lan Z, Peng Y. Prediction of clinical response to neoadjuvant therapy in advanced breast cancer by baseline B-mode ultrasound, shear-wave elastography, and pathological information. Front Oncol 2023; 13:1096571. [PMID: 37228493 PMCID: PMC10203521 DOI: 10.3389/fonc.2023.1096571] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2022] [Accepted: 04/18/2023] [Indexed: 05/27/2023] Open
Abstract
Background Neoadjuvant therapy (NAT) is the preferred treatment for advanced breast cancer nowadays. The early prediction of its responses is important for personalized treatment. This study aimed at using baseline shear wave elastography (SWE) ultrasound combined with clinical and pathological information to predict the clinical response to therapy in advanced breast cancer. Methods This retrospective study included 217 patients with advanced breast cancer who were treated in West China Hospital of Sichuan University from April 2020 to June 2022. The features of ultrasonic images were collected according to the Breast imaging reporting and data system (BI-RADS), and the stiffness value was measured at the same time. The changes were measured according to the Response evaluation criteria in solid tumors (RECIST1.1) by MRI and clinical situation. The relevant indicators of clinical response were obtained through univariate analysis and incorporated into a logistic regression analysis to establish the prediction model. The receiver operating characteristic (ROC) curve was used to evaluate the performance of the prediction models. Results All patients were divided into a test set and a validation set in a 7:3 ratio. A total of 152 patients in the test set, with 41 patients (27.00%) in the non-responders group and 111 patients (73.00%) in the responders group, were finally included in this study. Among all unitary and combined mode models, the Pathology + B-mode + SWE model performed best, with the highest AUC of 0.808 (accuracy 72.37%, sensitivity 68.47%, specificity 82.93%, P<0.001). HER2+, Skin invasion, Post mammary space invasion, Myometrial invasion and Emax were the factors with a significant predictive value (P<0.05). 65 patients were used as an external validation set. There was no statistical difference in ROC between the test set and the validation set (P>0.05). Conclusion As the non-invasive imaging biomarkers, baseline SWE ultrasound combined with clinical and pathological information can be used to predict the clinical response to therapy in advanced breast cancer.
Collapse
|
20
|
Zheng D, Zhou J, Qian L, Liu X, Chang C, Tang S, Zhang H, Zhou S. Biomimetic nanoparticles drive the mechanism understanding of shear-wave elasticity stiffness in triple negative breast cancers to predict clinical treatment. Bioact Mater 2023; 22:567-587. [DOI: 10.1016/j.bioactmat.2022.10.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 09/20/2022] [Accepted: 10/24/2022] [Indexed: 11/06/2022] Open
|
21
|
Li J, Sun B, Li Y, Li S, Wang J, Zhu Y, Lu H. Correlation analysis between shear-wave elastography and pathological profiles in breast cancer. Breast Cancer Res Treat 2023; 197:269-276. [PMID: 36374375 DOI: 10.1007/s10549-022-06804-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Accepted: 11/03/2022] [Indexed: 11/16/2022]
Abstract
PURPOSE To explore the correlation between shear-wave elastography (SWE) parameters and pathological profiles of invasive breast cancer. METHODS A total of 197 invasive breast cancers undergoing preoperative SWE and primary surgical treatment were included. Maximum elastic modulus (Emax), mean elastic modulus (Emean), and elastic modulus standard deviation (Esd) were calculated by SWE. Pathological profile was gold standard according to postoperative pathology. The relationship between SWE parameters and pathological factors were analyzed using univariate and multivariate analysis. RESULTS In univariate analysis, large cancers showed significantly higher Emax, Emean and Esd (all P < 0.001). Emax and Esd in the group of histological grade III were higher than those in the group of grade I (both P < 0.05). Invasive lobular carcinomas (ILC) showed higher Emean than invasive ductal carcinoma (IDC) (P < 0.001). Lymphovascular invasion (LVI) group showed higher Emax values than negative group (P < 0.05). Emax, Emean and Esd of the Ki-67 positive group presented higher values than negative group (all P < 0.05). Androgen receptor (AR) positive lesions had lower Esd than AR negative lesions (P < 0.05). In multivariate analysis, invasive size independently influenced Emax (P < 0.001). Invasive size and pathological type both independently influenced Emean (both P < 0.001). Invasive size and AR status were both independently influenced Esd (both P < 0.05). CONCLUSION SWE parameters correlated with pathological profiles of invasive breast cancer.In particular, AR positive group showed significantly low Esd than negative group.
Collapse
Affiliation(s)
- Junnan Li
- Department of Breast Imaging, Tianjin Medical University Cancer Institute & Hospital, National Clinical Research Center for Cancer, Tianjin's Clinical Research Center for Cancer, Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Key Laboratory of Cancer Prevention and Therapy, Tianjin, China
| | - Bo Sun
- The Second Department of Breast Cancer, Tianjin Medical University Cancer Institute & Hospital, National Clinical Research Center for Cancer, Tianjin's Clinical Research Center for Cancer, Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Key Laboratory of Cancer Prevention and Therapy, Tianjin, China
| | - Yanbo Li
- Department of Breast Imaging, Tianjin Medical University Cancer Institute & Hospital, National Clinical Research Center for Cancer, Tianjin's Clinical Research Center for Cancer, Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Key Laboratory of Cancer Prevention and Therapy, Tianjin, China
| | - Shuang Li
- Department of Bone and Tissue Oncology, Tianjin Hospital, Tianjin University, Tianjin, China
| | - Jiahui Wang
- Department of Breast Imaging, Tianjin Medical University Cancer Institute & Hospital, National Clinical Research Center for Cancer, Tianjin's Clinical Research Center for Cancer, Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Key Laboratory of Cancer Prevention and Therapy, Tianjin, China
| | - Ying Zhu
- Department of Breast Imaging, Tianjin Medical University Cancer Institute & Hospital, National Clinical Research Center for Cancer, Tianjin's Clinical Research Center for Cancer, Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Key Laboratory of Cancer Prevention and Therapy, Tianjin, China
| | - Hong Lu
- Department of Breast Imaging, Tianjin Medical University Cancer Institute & Hospital, National Clinical Research Center for Cancer, Tianjin's Clinical Research Center for Cancer, Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Key Laboratory of Cancer Prevention and Therapy, Tianjin, China. .,Tianjin Medical University Cancer Institute and Hospital, West Huan-Hu Rd, Ti Yuan Bei, Hexi District, Tianjin, 300060, People's Republic of China.
| |
Collapse
|
22
|
Li J, Liu Y, Li Y, Li S, Wang J, Zhu Y, Lu H. Comparison of diagnostic potential of shear wave elastography between breast mass lesions and non-mass-like lesions. Eur J Radiol 2023; 158:110609. [PMID: 36423364 DOI: 10.1016/j.ejrad.2022.110609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Revised: 10/17/2022] [Accepted: 11/10/2022] [Indexed: 11/17/2022]
Abstract
BACKGROUND Shear wave elastography (SWE) can improve the specificity of B-mode ultrasound (US) without reducing the sensitivity for breast cancer diagnosis. Existing research on SWE includes both mass lesions and non‑mass‑like (NML) lesions or only NML lesions; however, there are no studies comparing the diagnostic potential of SWE in the detection of mass and NML lesions in the same trial. OBJECTIVE This study aimed to compare the diagnostic performance of SWE in detecting mass lesions and NML lesions and determine the different individualised thresholds of the SWE parameters according to the lesion type. METHODS This Study included 623 breast lesions of 562 consecutive women, who were scheduled for conventional US and SWE between January 2021 and December 2021. The diagnostic performances of conventional US and each quantitative SWE parameter (maximum elastic modulus [Emax], mean elastic modulus [Emean], and elastic modulus standard deviation [Esd]) were assessed. Histological diagnosis for all Breast Imaging Reporting and Database System (BI-RADS) category 4/5 patients and some BI-RADS category 3 patients and the follow-up results of other BI-RADS category 3 patients were used as the reference standard. RESULTS In this study, 281 benign lesions and 342 malignant lesions were identified. The diagnostic performance of conventional US and SWE was better in the mass lesion group than in the NML lesion group. Every SWE parameter had a different threshold in each group, and the thresholds of the SWE parameters were higher in the mass lesion group than in the NML lesion group. In the mass lesion group, Esd had the highest Az value, whereas in the NML lesion group, Emax had the highest Az value. In both the mass and NML lesion groups, the diagnostic specificity of the combination of conventional US and SWE was significantly higher than that of conventional US alone (P < 0.05), without a significantly decrease in the diagnosticsensitivity. CONCLUSIONS SWE could increase the confidence of breast ultrasound diagnosis, especially for NML lesions. NML lesions had lower thresholds of SWE parameters than did the mass lesions.
Collapse
Affiliation(s)
- Junnan Li
- Department of Breast Imaging, Tianjin Medical University Cancer Institute & Hospital, National Clinical Research Center for Cancer; Tianjin's Clinical Research Center for Cancer; Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education; Key Laboratory of Cancer Prevention and Therapy, Tianjin, PR China
| | - Yacong Liu
- Department of Breast Imaging, Tianjin Medical University Cancer Institute & Hospital, National Clinical Research Center for Cancer; Tianjin's Clinical Research Center for Cancer; Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education; Key Laboratory of Cancer Prevention and Therapy, Tianjin, PR China
| | - Yanbo Li
- Department of Breast Imaging, Tianjin Medical University Cancer Institute & Hospital, National Clinical Research Center for Cancer; Tianjin's Clinical Research Center for Cancer; Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education; Key Laboratory of Cancer Prevention and Therapy, Tianjin, PR China
| | - Shuang Li
- Department of Bone and Tissue Oncology, Tianjin Hospital, Tianjin University, Tianjin, PR China
| | - Jiahui Wang
- Department of Breast Imaging, Tianjin Medical University Cancer Institute & Hospital, National Clinical Research Center for Cancer; Tianjin's Clinical Research Center for Cancer; Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education; Key Laboratory of Cancer Prevention and Therapy, Tianjin, PR China
| | - Ying Zhu
- Department of Breast Imaging, Tianjin Medical University Cancer Institute & Hospital, National Clinical Research Center for Cancer; Tianjin's Clinical Research Center for Cancer; Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education; Key Laboratory of Cancer Prevention and Therapy, Tianjin, PR China
| | - Hong Lu
- Department of Breast Imaging, Tianjin Medical University Cancer Institute & Hospital, National Clinical Research Center for Cancer; Tianjin's Clinical Research Center for Cancer; Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education; Key Laboratory of Cancer Prevention and Therapy, Tianjin, PR China.
| |
Collapse
|
23
|
Quantitative Assessment of Breast-Tumor Stiffness Using Shear-Wave Elastography Histograms. Diagnostics (Basel) 2022; 12:diagnostics12123140. [PMID: 36553148 PMCID: PMC9777730 DOI: 10.3390/diagnostics12123140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 12/08/2022] [Accepted: 12/11/2022] [Indexed: 12/15/2022] Open
Abstract
Purpose: Shear-wave elastography (SWE) measures tissue elasticity using ultrasound waves. This study proposes a histogram-based SWE analysis to improve breast malignancy detection. Methods: N = 22/32 (patients/tumors) benign and n = 51/64 malignant breast tumors with histological ground truth. Colored SWE heatmaps were adjusted to a 0−180 kPa scale. Normalized, 250-binned RGB histograms were used as image descriptors based on skewness and area under curve (AUC). The histogram method was compared to conventional SWE metrics, such as (1) the qualitative 5-point scale classification and (2) average stiffness (SWEavg)/maximal tumor stiffness (SWEmax) within the tumor B-mode boundaries. Results: The SWEavg and SWEmax did not discriminate malignant lesions in this database, p > 0.05, rank sum test. RGB histograms, however, differed between malignant and benign tumors, p < 0.001, Kolmogorov−Smirnoff test. The AUC analysis of histograms revealed the reduction of soft-tissue components as a significant SWE biomarker (p = 0.03, rank sum). The diagnostic accuracy of the suggested method is still low (Se = 0.30 for Se = 0.90) and a subject for improvement in future studies. Conclusions: Histogram-based SWE quantitation improved the diagnostic accuracy for malignancy compared to conventional average SWE metrics. The sensitivity is a subject for improvement in future studies.
Collapse
|
24
|
Zhong X, Chen L, Long H, Zheng R, Su L, Duan Y, Xie X, Lin M. The "stiff rim" sign of hepatocellular carcinoma on shear wave elastography: correlation with pathological features and potential prognostic value. ABDOMINAL RADIOLOGY (NEW YORK) 2022; 47:4115-4125. [PMID: 35962810 DOI: 10.1007/s00261-022-03628-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 07/01/2022] [Accepted: 07/13/2022] [Indexed: 01/18/2023]
Abstract
PURPOSE To explore the pathologic basis, the influencing factors and potential prognostic value of the stiff rim sign in two-dimensional shear wave elastography (2D-SWE) of hepatocellular carcinoma (HCC). METHODS HCC patients who underwent tumor 2D-SWE examination before resection were prospectively enrolled. The stiff rim sign was defined as increased stiffness in the peritumoral region. Interobserver and intraobserver variability of the stiff rim sign was assessed. The correlation between the stiff rim sign and pathological characteristics was analyzed. Multivariate analysis was performed to examine clinical and radiological factors influencing the appearance of stiff rim sign. The Kaplan-Meier method was used to analyze the relationship between recurrence-free survival (RFS) and the stiff rim sign. RESULTS The stiff rim sign on 2D-SWE was present in 44.7% of HCC lesions. Interobserver agreement and intraobserver agreement for the stiff rim sign were substantial (κ = 0.772) and almost perfect (κ = 0.895), respectively. Pathologically, the stiff rim sign was associated with capsule status, capsule integrity, capsule thickness, proportion of peritumoral fibrous tissue, and peritumoral fibrous arrangement. Multivariate analysis showed that tumor size was an independent clinical predictor for the appearance of stiff rim sign (OR 1.201, p = 0.008). Kaplan-Meier analysis showed RFS was significantly poorer in the stiff rim sign (+) group than the stiff rim sign (-) group in solitary tumors smaller than 5 cm (p = 0.007) and solitary tumors with intratumoral stiffness less than 33.7 kPa (p = 0.007). CONCLUSION The stiff rim sign on 2D-SWE was mainly correlated with peritumoral fibrous tissue status and was a poor prognostic indicator for HCC.
Collapse
Affiliation(s)
- Xian Zhong
- Department of Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, No. 58 Zhongshan Second Road, Guangzhou, 510080, China
| | - Lili Chen
- Department of Pathology, The First Affiliated Hospital of Sun Yat-Sen University, 58 Zhongshan Second Road, Guangzhou, 510080, China
| | - Haiyi Long
- Department of Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, No. 58 Zhongshan Second Road, Guangzhou, 510080, China
| | - Ruiying Zheng
- Department of Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, No. 58 Zhongshan Second Road, Guangzhou, 510080, China
| | - Liya Su
- Department of Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, No. 58 Zhongshan Second Road, Guangzhou, 510080, China
| | - Yu Duan
- Department of Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, No. 58 Zhongshan Second Road, Guangzhou, 510080, China
| | - Xiaoyan Xie
- Department of Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, No. 58 Zhongshan Second Road, Guangzhou, 510080, China
| | - Manxia Lin
- Department of Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, No. 58 Zhongshan Second Road, Guangzhou, 510080, China.
| |
Collapse
|
25
|
de Oliveira J, de Souza MA, Assef AA, Maia JM. Multi-Sensing Techniques with Ultrasound for Musculoskeletal Assessment: A Review. SENSORS (BASEL, SWITZERLAND) 2022; 22:9232. [PMID: 36501933 PMCID: PMC9740760 DOI: 10.3390/s22239232] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 10/22/2022] [Accepted: 10/27/2022] [Indexed: 06/17/2023]
Abstract
The study of muscle contractions generated by the muscle-tendon unit (MTU) plays a critical role in medical diagnoses, monitoring, rehabilitation, and functional assessments, including the potential for movement prediction modeling used for prosthetic control. Over the last decade, the use of combined traditional techniques to quantify information about the muscle condition that is correlated to neuromuscular electrical activation and the generation of muscle force and vibration has grown. The purpose of this review is to guide the reader to relevant works in different applications of ultrasound imaging in combination with other techniques for the characterization of biological signals. Several research groups have been using multi-sensing systems to carry out specific studies in the health area. We can divide these studies into two categories: human-machine interface (HMI), in which sensors are used to capture critical information to control computerized prostheses and/or robotic actuators, and physiological study, where sensors are used to investigate a hypothesis and/or a clinical diagnosis. In addition, the relevance, challenges, and expectations for future work are discussed.
Collapse
Affiliation(s)
- Jonathan de Oliveira
- Graduate Program in Health Technology (PPGTS), Pontifical Catholic University of Paraná, Curitiba 80215-901, Brazil
| | - Mauren Abreu de Souza
- Graduate Program in Health Technology (PPGTS), Pontifical Catholic University of Paraná, Curitiba 80215-901, Brazil
| | - Amauri Amorin Assef
- Graduate Program in Electrical and Computer Engineering (CPGEI), Federal University of Technology of Paraná (UTFPR), Curitiba 80230-901, Brazil
| | - Joaquim Miguel Maia
- Graduate Program in Electrical and Computer Engineering (CPGEI), Federal University of Technology of Paraná (UTFPR), Curitiba 80230-901, Brazil
- Electronics Engineering Department (DAELN), Federal University of Technology of Paraná (UTFPR), Curitiba 80230-901, Brazil
| |
Collapse
|
26
|
Chen Y, Lu J, Li J, Liao J, Huang X, Zhang B. Evaluation of diagnostic efficacy of multimode ultrasound in BI-RADS 4 breast neoplasms and establishment of a predictive model. Front Oncol 2022; 12:1053280. [PMID: 36505867 PMCID: PMC9730703 DOI: 10.3389/fonc.2022.1053280] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2022] [Accepted: 11/04/2022] [Indexed: 11/25/2022] Open
Abstract
Objectives To explore the diagnostic efficacy of ultrasound (US), two-dimensional and three-dimensional shear-wave elastography (2D-SWE and 3D-SWE), and contrast-enhanced ultrasound (CEUS) in breast neoplasms in category 4 based on the Breast Imaging Reporting and Data System (BI-RADS) from the American College of Radiology (ACR) and to develop a risk-prediction nomogram based on the optimal combination to provide a reference for the clinical management of BI-RADS 4 breast neoplasms. Methods From September 2021 to April 2022, a total of 104 breast neoplasms categorized as BI-RADS 4 by US were included in this prospective study. There were 78 breast neoplasms randomly assigned to the training cohort; the area under the receiver-operating characteristic curve (AUC), 95% confidence interval (95% CI), sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 2D-SWE, 3D-SWE, CEUS, and their combination were analyzed and compared. The optimal combination was selected to develop a risk-prediction nomogram. The performance of the nomogram was assessed by a validation cohort of 26 neoplasms. Results Of the 78 neoplasms in the training cohort, 16 were malignant and 62 were benign. Among the 26 neoplasms in the validation cohort, 6 were malignant and 20 were benign. The AUC values of 2D-SWE, 3D-SWE, and CEUS were not significantly different. After a comparison of the different combinations, 2D-SWE+CEUS showed the optimal performance. Least absolute shrinkage and selection operator (LASSO) regression was used to filter the variables in this combination, and the variables included Emax, Eratio, enhancement mode, perfusion defect, and area ratio. Then, a risk-prediction nomogram with BI-RADS was built. The performance of the nomogram was better than that of the radiologists in the training cohort (AUC: 0.974 vs. 0.863). In the validation cohort, there was no significant difference in diagnostic accuracy between the nomogram and the experienced radiologists (AUC: 0.946 vs. 0.842). Conclusions US, 2D-SWE, 3D-SWE, CEUS, and their combination could improve the diagnostic efficiency of BI-RADS 4 breast neoplasms. The diagnostic efficacy of US+3D-SWE was not better than US+2D-SWE. US+2D-SWE+CEUS showed the optimal diagnostic performance. The nomogram based on US+2D-SWE+CEUS performs well.
Collapse
|
27
|
Tang L, Wang Y, Chen P, Chen M, Jiang L. Clinical use and adjustment of ultrasound elastography for breast lesions followed WFUMB guidelines and recommendations in the real world. Front Oncol 2022; 12:1022917. [PMID: 36505783 PMCID: PMC9730323 DOI: 10.3389/fonc.2022.1022917] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Accepted: 11/07/2022] [Indexed: 11/25/2022] Open
Abstract
Objective This study aimed to explore the value of strain elastography (SE) and shear wave elastography (SWE) following the World Federation of Ultrasound in Medicine and Biology (WFUMB) guidelines and recommendations in the real world in distinguishing benign and malignant breast lesions and reducing biopsy of BI-RADS (Breast Imaging Reporting and Data System) 4a lesions. Methods This prospective study included 274 breast lesions. The elastography score (ES) by the Tsukuba score, the strain ratio (SR) for SE, and Emax for SWE of the lesion(A) and the regions(A') included the lesion and the margin (0.5-5 mm) surrounding the lesion were measured. The sensitivity, specificity, and AUC were calculated and compared by the cutoff values recommended by WFUMB guidelines. Results When scores of 1 to 3 were classified as probably benign by WFUMB recommendation, the ES was significantly higher in malignant lesions compared to benign lesions (p < 0.05) in all lesions. For the cohort by size >20 mm, the sensitivity was 100%, and the specificity was 45.5%. ES had the highest AUC: 0.79(95% CI 0.72-0.86) with a sensitivity of 96.2%, and a specificity of 61.8% for the cohort by size ≤20 mm. For the Emax-A'-S2.5mm, when the high stiffness would be considered with Emax above 80 kPa in SWE, the malignant lesions were diagnosed with a sensitivity of 95.8%, a specificity of 43.3% for all lesions, a sensitivity of 88.5% for lesions with size ≤20 mm, and sensitivity of 100.0% for lesions with size >20 mm. In 84 lesions of BI-RADS category 4a, if category 4a lesions with ES of 1-3 points or Emax-A'-S2.5 less than 80 kPa could be downgraded to category 3, 52 (61.9%) lesions could be no biopsy, including two malignancies. If category 4a lesions with ES of 1-3 points and Emax-A'-S2.5 less than 80kPa could be downgraded to category 3, 23 (27.4%) lesions could be no biopsy, with no malignancy. Conclusions The elastography score for SE and Emax-A' for SWE after our modification were beneficial in the diagnosis of breast cancer. The combination of SWE and SE could effectively reduce the biopsy rate of BI-RADS category 4a lesions.
Collapse
Affiliation(s)
- Lei Tang
- Department of Ultrasound, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China,Department of Ultrasound Medicine, Tongren Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Yuqun Wang
- Department of Ultrasound Medicine, Tongren Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Pingping Chen
- Department of Ultrasound Medicine, Tongren Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Man Chen
- Department of Ultrasound Medicine, Tongren Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China,*Correspondence: Lixin Jiang, ; Man Chen,
| | - Lixin Jiang
- Department of Ultrasound, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China,*Correspondence: Lixin Jiang, ; Man Chen,
| |
Collapse
|
28
|
Liu R, Gao L, Shi X, Ma L, Wang O, Xia W, Hu Y, Xia Y, Jiang Y. Shear wave elastography for differentiating parathyroid neoplasms with malignant diagnosis or uncertain malignant potential from parathyroid adenomas: initial experience. Cancer Imaging 2022; 22:64. [PMID: 36415001 PMCID: PMC9682726 DOI: 10.1186/s40644-022-00503-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Accepted: 11/07/2022] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVE Parathyroid carcinoma (PC) and atypical parathyroid tumor (APT) are rare parathyroid disorders carrying the risk of recurrence of varying degrees. This study aims to explore the value of 2D-shear wave elastography (SWE) in the discrimination of PC/APT among suspicious parathyroid lesions. METHODS AND MATERIALS In this prospective study, patients with primary hyperparathyroidism and suspicious parathyroid lesions on ultrasonography (US) were recruited. All the lesions were assessed by SWE before surgery. The velocity (m/s), Young's modulus (Kpa), and elastogram of SWE were compared between pathologically proven parathyroid carcinoma or atypical parathyroid tumor (Group1) and parathyroid adenoma (Group2). All the SWE parameters were displayed at the setting of 50 or 70 kPa. Correlations between SWE and the lesion size as well as biochemical parameters were analyzed. RESULTS 36 target lesions were enrolled for analysis. The mean shear wave velocity (SWV) between the two groups was 2.4 m/s vs 1.9 m/s, respectively, while the mean Young's modulus was 11.1 kPa vs 18.2 kPa, respectively. The cut-off values are 2.35 m/s and 17.05 kPa correspondingly. The sensitivity and specificity of the selecting cut-off values were 0.56 vs 0.63 and 0.95 vs 1.0 (area under the curve [AUC]: 0.813 vs 0.852 [95% confidence interval (CI): 0.669-0.956 vs 0.720-0.983]; p < 0.001, p < 0.001; respectively). In contrast, the max SWV and Young's modulus showed a better sensitivity of 0.75 and 0.81, respectively. The "colored lesion" and "stiff rim" patterns on the elastogram are more indicated in parathyroid carcinoma and atypical parathyroid tumor, whereas the negative elastogram prevails in parathyroid adenoma. The SWV and Young's modulus of the parathyroid lesions were independent of the tumor size, but the max SWV and Young's modulus slightly correlated with serum parathyroid hormone concentration (PTH) (r = 0.398, p = 0.016; r = 0.396, p = 0.017). CONCLUSIONS 2D-shear wave elastography plays a useful role in the preoperative assessment of parathyroid lesions with suspicious malignancy. The mean SWV and Young's modulus are advised as the favored diagnostic parameter with the best AUC and excellent specificities, while the max SWV and Young's modulus are more sensitive to distinguish the PC and APT compared with other parameters.
Collapse
Affiliation(s)
- Ruifeng Liu
- grid.506261.60000 0001 0706 7839Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shuaifuyuan 1#, Dongcheng District, Beijing, 10073 China
| | - Luying Gao
- grid.506261.60000 0001 0706 7839Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shuaifuyuan 1#, Dongcheng District, Beijing, 10073 China
| | - Xinlong Shi
- grid.506261.60000 0001 0706 7839Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shuaifuyuan 1#, Dongcheng District, Beijing, 10073 China
| | - Liyuan Ma
- grid.506261.60000 0001 0706 7839Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shuaifuyuan 1#, Dongcheng District, Beijing, 10073 China
| | - Ou Wang
- grid.506261.60000 0001 0706 7839Department of Endocrinology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shuaifuyuan 1#, Dongcheng District, Beijing, 100730 China
| | - Weibo Xia
- grid.506261.60000 0001 0706 7839Department of Endocrinology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shuaifuyuan 1#, Dongcheng District, Beijing, 100730 China
| | - Ya Hu
- grid.506261.60000 0001 0706 7839Department of General Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shuaifuyuan 1#, Dongcheng District, Beijing, 100730 China
| | - Yu Xia
- grid.506261.60000 0001 0706 7839Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shuaifuyuan 1#, Dongcheng District, Beijing, 10073 China
| | - Yuxin Jiang
- grid.506261.60000 0001 0706 7839Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shuaifuyuan 1#, Dongcheng District, Beijing, 10073 China
| |
Collapse
|
29
|
Deng B, Zhao Z, Kong W, Han C, Shen X, Zhou C. Biological role of matrix stiffness in tumor growth and treatment. J Transl Med 2022; 20:540. [PMID: 36419159 PMCID: PMC9682678 DOI: 10.1186/s12967-022-03768-y] [Citation(s) in RCA: 64] [Impact Index Per Article: 32.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Accepted: 11/09/2022] [Indexed: 11/24/2022] Open
Abstract
In recent years, the biological role of changes in physical factors in carcinogenesis and progression has attracted increasing attention. Matrix stiffness, also known as ECM stress, is a critical physical factor of tumor microenvironment and remains alternating during carcinogenesis as a result of ECM remodeling through activation of cancer-associated fibroblasts and extracellular collagen accumulation, crosslinking and fibrosis. Different content and density of extracellular collagen in ECM endows matrix with varying stiffness. Physical signals induced by matrix stiffness are transmitted to tumor cells primarily by the integrins receptor family and trigger a series of mechanotransduction that result in changes in tumor cell morphology, proliferative capacity, and invasive ability. Importantly, accumulating evidence revealed that changes in matrix stiffness in tumor tissues greatly control the sensitivity of tumor cells in response to chemotherapy, radiotherapy, and immunotherapy through integrin signaling, YAP signaling, and related signaling pathways. Here, the present review analyzes the current research advances on matrix stiffness and tumor cell behavior with a view to contributing to tumor cell growth and treatment, with the hope of improving the understanding of the biological role of matrix stiffness in tumors.
Collapse
Affiliation(s)
- Boer Deng
- grid.24696.3f0000 0004 0369 153XDepartment of Gynecologic Oncology, Beijing Obstetrics and Gynecology Hospital, Capital Medical University, Beijing Maternal and Child Health Care Hospital, Beijing, People’s Republic of China ,grid.10698.360000000122483208Division of Gynecologic Oncology, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 USA
| | - Ziyi Zhao
- grid.24696.3f0000 0004 0369 153XDepartment of Gynecologic Oncology, Beijing Obstetrics and Gynecology Hospital, Capital Medical University, Beijing Maternal and Child Health Care Hospital, Beijing, People’s Republic of China ,grid.10698.360000000122483208Division of Gynecologic Oncology, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 USA
| | - Weimin Kong
- grid.24696.3f0000 0004 0369 153XDepartment of Gynecologic Oncology, Beijing Obstetrics and Gynecology Hospital, Capital Medical University, Beijing Maternal and Child Health Care Hospital, Beijing, People’s Republic of China ,grid.10698.360000000122483208Division of Gynecologic Oncology, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 USA
| | - Chao Han
- grid.24696.3f0000 0004 0369 153XDepartment of Gynecologic Oncology, Beijing Obstetrics and Gynecology Hospital, Capital Medical University, Beijing Maternal and Child Health Care Hospital, Beijing, People’s Republic of China
| | - Xiaochang Shen
- grid.24696.3f0000 0004 0369 153XDepartment of Gynecologic Oncology, Beijing Obstetrics and Gynecology Hospital, Capital Medical University, Beijing Maternal and Child Health Care Hospital, Beijing, People’s Republic of China ,grid.10698.360000000122483208Division of Gynecologic Oncology, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 USA
| | - Chunxiao Zhou
- grid.10698.360000000122483208Division of Gynecologic Oncology, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 USA ,grid.10698.360000000122483208Lineberger Cancer Center, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 USA
| |
Collapse
|
30
|
Evaluating Different Quantitative Shear Wave Parameters of Ultrasound Elastography in the Diagnosis of Lymph Node Malignancies: A Systematic Review and Meta-Analysis. Cancers (Basel) 2022; 14:cancers14225568. [PMID: 36428661 PMCID: PMC9688428 DOI: 10.3390/cancers14225568] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 11/08/2022] [Accepted: 11/11/2022] [Indexed: 11/16/2022] Open
Abstract
Shear wave elastography (SWE) has shown promise in distinguishing lymph node malignancies. However, the diagnostic accuracies of various SWE parameters that quantify tissue stiffness are yet to be demonstrated. To evaluate the pooled diagnostic accuracy of different SWE parameters for differentiating lymph node malignancies, we conducted a systematic screening of four databases using the PRISMA guidelines. Lymph node biopsy was adopted as the reference standard. Emax (maximum stiffness), Emean (mean stiffness), Emin (minimum stiffness), and Esd (standard deviation) SWE parameters were subjected to separate meta-analyses. A sub-group analysis comparing the use of Emax in cervical (including thyroid) and axillary lymph node malignancies was also conducted. Sixteen studies were included in this meta-analysis. Emax and Esd demonstrated the highest pooled sensitivity (0.78 (95% CI: 0.69-0.87); 0.78 (95% CI: 0.68-0.87)), while Emean demonstrated the highest pooled specificity (0.93 (95% CI: 0.88-0.98)). From the sub-group analysis, the diagnostic performance did not differ significantly in cervical and axillary LN malignancies. In conclusion, SWE is a promising adjunct imaging technique to conventional ultrasonography in the diagnosis of lymph node malignancy. SWE parameters of Emax and Esd have been identified as better choices of parameters for screening clinical purposes.
Collapse
|
31
|
Liu J, Wang X, Hu M, Zheng Y, Zhu L, Wang W, Hu J, Zhou Z, Dai Y, Dong F. Development of an ultrasound-based radiomics nomogram to preoperatively predict Ki-67 expression level in patients with breast cancer. Front Oncol 2022; 12:963925. [PMID: 36046035 PMCID: PMC9421073 DOI: 10.3389/fonc.2022.963925] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Accepted: 07/20/2022] [Indexed: 11/13/2022] Open
Abstract
ObjectiveTo develop and validate a radiomics nomogram that could incorporate clinicopathological characteristics and ultrasound (US)-based radiomics signature to non-invasively predict Ki-67 expression level in patients with breast cancer (BC) preoperatively.MethodsA total of 328 breast lesions from 324 patients with BC who were pathologically confirmed in our hospital from June 2019 to October 2020 were included, and they were divided into high Ki-67 expression level group and low Ki-67 expression level group. Routine US and shear wave elastography (SWE) were performed for each lesion, and the ipsilateral axillary lymph nodes (ALNs) were scanned for abnormal changes. The datasets were randomly divided into training and validation cohorts with a ratio of 7:3. Correlation analysis and the least absolute shrinkage and selection operator (LASSO) were used to select the radiomics features obtained from gray-scale US images of BC patients, and each radiomics score (Rad-score) was calculated. Afterwards, multivariate logistic regression analysis was used to establish a radiomics nomogram based on the radiomics signature and clinicopathological characteristics. The prediction performance of the nomogram was assessed by the area under the receiver operating characteristic curve (AUC), the calibration curve, and decision curve analysis (DCA) using the results of immunohistochemistry as the gold standard.ResultsThe radiomics signature, consisted of eight selected radiomics features, achieved a nearly moderate prediction efficacy with AUC of 0.821 (95% CI:0.764-0.880) and 0.713 (95% CI:0.612-0.814) in the training and validation cohorts, respectively. The radiomics nomogram, incorporating maximum diameter of lesions, stiff rim sign, US-reported ALN status, and radiomics signature showed a promising performance for prediction of Ki-67 expression level, with AUC of 0.904 (95% CI:0.860-0.948) and 0.890 (95% CI:0.817-0.964) in the training and validation cohorts, respectively. The calibration curve and DCA indicated promising consistency and clinical applicability.ConclusionThe proposed US-based radiomics nomogram could be used to non-invasively predict Ki-67 expression level in BC patients preoperatively, and to assist clinicians in making reliable clinical decisions.
Collapse
Affiliation(s)
- Jinjin Liu
- Department of Ultrasound, The First Affiliated Hospital of Soochow University, Suzhou, China
| | - Xuchao Wang
- Department of Radiology, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Suzhou, China
| | - Mengshang Hu
- Department of Ultrasound, The First Affiliated Hospital of Soochow University, Suzhou, China
| | - Yan Zheng
- Department of Ultrasound, The First Affiliated Hospital of Soochow University, Suzhou, China
| | - Lin Zhu
- Department of Ultrasound, The First Affiliated Hospital of Soochow University, Suzhou, China
| | - Wei Wang
- Department of Ultrasound, The First Affiliated Hospital of Soochow University, Suzhou, China
| | - Jisu Hu
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
| | - Zhiyong Zhou
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
- *Correspondence: Zhiyong Zhou, ; Yakang Dai, ; Fenglin Dong,
| | - Yakang Dai
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
- *Correspondence: Zhiyong Zhou, ; Yakang Dai, ; Fenglin Dong,
| | - Fenglin Dong
- Department of Ultrasound, The First Affiliated Hospital of Soochow University, Suzhou, China
- *Correspondence: Zhiyong Zhou, ; Yakang Dai, ; Fenglin Dong,
| |
Collapse
|
32
|
Zhou Y, Wu J. Which combination of different ultrasonography modalities is more appropriate to diagnose breast cancer?: A network meta-analysis (a PRISMA-compliant article). Medicine (Baltimore) 2022; 101:e29955. [PMID: 35945707 PMCID: PMC9351919 DOI: 10.1097/md.0000000000029955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
BACKGROUND Abundant amount of literature that analyze the various detection of different ultrasound methods, no comprehensive literature that investigates the diagnostic values of breast cancer (BC) by different ultrasonography modalities through a network meta-analysis (NMA) has been made available. Each imaging diagnostic examination has its own advantages and disadvantages, and any imaging examination is not enough to make an accurate diagnosis of the disease. Thus, this study aimed to compare diagnostic values among different ultrasonography modalities, including the information of 2-dimension, stiffness and blood flow, by a network meta-analysis in the hopes of understanding which imaging methods are better and which combination of different ultrasonography modalities is more appropriate to diagnose BC. METHODS We made use of Cochrane Library, PubMed, and Embase in order to obtain literature and papers. The combination analysis of both direct and indirect evidence in terms of sensitivity, specificity, positive predictive value (PPV), negative predictive value(NPV) and accuracy was conducted so as to assess the odds ratios (ORs) and surface under the cumulative ranking curve (SUCRA) values of the 8 different ultrasound methods. RESULTS A total of 36 eligible diagnostic tests regarding 8 ultrasound methods were included in the study. According to this network meta-analysis, Breast Imaging Reporting and Data System (BI-RADS) 4b exhibited higher specificity, PPV, and accuracy and lower sensitivity and NPV than BI-RADS 4a. Contrast-enhanced ultrasound (CEUS) had the highest sensitivity, PPV, NPV and accuracy and superb microvascular imaging (SMI) had the highest specificity among color Doppler flow imaging (CDFI), power Doppler imaging(PDI), SMI and CEUS. There was no significant difference in diagnostic indexes between SMI and CEUS. Shear wave elastrography (SWE) had higher PPV and accuracy and lower sensitivity, specificity NPV than strain elastography (SE). CONCLUSION The results of this network meta-analysis suggested more appropriate combination of different ultrasound modalities is BI-RADS 4b, SMI, and SWE for the diagnosis of breast cancer.
Collapse
Affiliation(s)
- Yang Zhou
- Ultrasound department of the First Affiliated Hospital of Dalian Medical University
| | - Jialing Wu
- Ultrasound department of the First Affiliated Hospital of Dalian Medical University
- *Correspondence: Jialing Wu, No. 222 Zhongshan Road, Xigang District, Dalian City, Liaoning Province, China (e-mail: )
| |
Collapse
|
33
|
Xu Z, Wang Y, Chen M, Zhang Q. Multi-region radiomics for artificially intelligent diagnosis of breast cancer using multimodal ultrasound. Comput Biol Med 2022; 149:105920. [DOI: 10.1016/j.compbiomed.2022.105920] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Revised: 07/06/2022] [Accepted: 07/30/2022] [Indexed: 11/03/2022]
|
34
|
Cui YY, He NA, Ye XJ, Hu L, Xie L, Zhong W, Zhang CX. Evaluation of Tissue Stiffness Around Lesions by Sound Touch Shear Wave Elastography in Breast Malignancy Diagnosis. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:1672-1680. [PMID: 35672199 DOI: 10.1016/j.ultrasmedbio.2022.04.219] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/16/2022] [Revised: 03/09/2022] [Accepted: 04/29/2022] [Indexed: 06/15/2023]
Abstract
The aim of the study described here was to assess the evaluation of tissue stiffness around lesions by sound touch shear wave elastography (STE) in breast malignancy diagnosis. This was an institutional ethics committee-approved, single-center study. A total of 90 women with breast masses examined with conventional ultrasound and STE were eligible for enrollment from December 2020 to July 2021. The maximum and mean elastic values of masses, Emax and Emean, were determined. Shell function was used to measure the maximum and mean elastic values of tissues around masses in annular shells 0.5, 1.0, 1.5 and 2.0 mm wide, recorded as corresponding Emax-shell and Emean-shell. All parameters were analyzed and compared with histopathologic results. Receiver operating characteristic curves were constructed to assess diagnostic performance. Logistic regression analysis was conducted to determine the best diagnostic model. Collagen fiber content of tissues around breast lesions was evaluated using Masson staining and ImageJ software. Ninety women with breast masses were included in this study; 50 had benign (mean diameter 15.84 ± 4.39 mm) and 40 had malignant (mean diameter 17.40 ± 5.42 mm) masses. The diagnostic value of Emax-shell-2.0 was the highest (area under the curve = 0.930) with a sensitivity of 87.5% and specificity of 88%. According to stepwise logistic regression analysis, Emax-shell-2.0 and age were independent predictors of malignancy. Emax-shell-2.0 was also found to be highly correlated with the collagen fiber content of tissue in the malignant group (r = 0.877). Tissue stiffness around lesions measured by STE is a useful metric in identifying malignant breast masses by reflecting collagen fiber content, and Emax-shell-2.0 performs best.
Collapse
Affiliation(s)
- Ya-Yun Cui
- Department of Ultrasound, First Affiliated Hospital of Anhui Medical University, Hefei, Anhui, China; Department of Ultrasound, First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, China
| | - Nian-An He
- Department of Ultrasound, First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, China
| | - Xian-Jun Ye
- Department of Ultrasound, First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, China
| | - Lei Hu
- Department of Ultrasound, First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, China
| | - Li Xie
- Department of Ultrasound, First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, China
| | - Wen Zhong
- Department of Pathology, First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, China
| | - Chao-Xue Zhang
- Department of Ultrasound, First Affiliated Hospital of Anhui Medical University, Hefei, Anhui, China.
| |
Collapse
|
35
|
Mahadevan GSV, Chakkalakkoombil SV, Kayal S, Dharanipragada K, Toi PC, Ananthakrishnan R. Evaluation of change in tumor stiffness measured by acoustic radiation force impulse imaging for early prediction of response to neoadjuvant chemotherapy in breast cancer. JOURNAL OF CLINICAL ULTRASOUND : JCU 2022; 50:666-674. [PMID: 35353384 DOI: 10.1002/jcu.23201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2021] [Revised: 01/16/2022] [Accepted: 03/02/2022] [Indexed: 06/14/2023]
Abstract
OBJECTIVES In this study, the role of change in tumor stiffness between pre- and post-two cycles of neoadjuvant chemotherapy (NACT) measured by Acoustic Radiation Force Impulse (ARFI) imaging for predicting the response to NACT in breast cancer was analyzed. METHODS Fifty-two adult women with biopsy-proven locally advanced breast cancer and early-stage breast cancer who received NACT followed by either modified radical mastectomy or breast conservation surgery were included in the study. Tumor stiffness represented by shear wave velocity (SWV) in meter per second by ARFI imaging was measured before and after two cycles of NACT. Participants were categorized into responders and nonresponders based on pathological response assessment from the postoperative specimen. The association of change in tumor stiffness between pre- and post-two cycles of NACT with final pathological response status was assessed. RESULTS The mean change in SWV before and after completion of two cycles of NACT was 0.42 ± 0.16 and 0.17 ± 0.11 m/s in responders and nonresponders, respectively, and this difference was proven to be statistically significant (p < 0.001) suggesting that tumors that exhibit a larger reduction in tumor stiffness, respond better. An SWV reduction cut-off of 0.295 m/s between baseline and post-two cycles of NACT was also arrived at, which can discriminate between responders and nonresponders with a sensitivity and specificity of 88% and 83%, respectively. CONCLUSION Difference in tumor stiffness measured by ARFI imaging before and after two cycles of chemotherapy can be used as a reliable early predictor of response to chemotherapy in breast cancer.
Collapse
Affiliation(s)
| | | | - Smita Kayal
- Department of Medical Oncology, JIPMER, Pondicherry, India
| | | | - Pampa Ch Toi
- Department of Pathology, JIPMER, Pondicherry, India
| | | |
Collapse
|
36
|
Yu JF, Zhang S, Yin HH, Zhou BG, Pu YY, Fang Y, Du D, Zhang Y, Xu HX. Two-dimensional shear wave elastography with two different systems for the diagnosis of breast lesions. Clin Hemorheol Microcirc 2022; 82:53-62. [DOI: 10.3233/ch-221471] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND: Two-dimensional (2D) - shear wave elastography (SWE) has made promising advances in the diagnostic of breast lesions. However, few studies have assessed whether the diagnostic effectiveness of different platforms employing 2D-SWE is equal or different. OBJECTIVE: To compare the diagnostic effectiveness of 2D-SWE techniques from two different systems in differentiating malignant breast lesions from benign ones. METHODS: A total of 84 breast lesions were retrospectively analyzed by experienced radiologists using 2D-SWE on two ultrasound systems, i.e. system-1 (LOGIQ E9 system, GE Healthcare, Wauwatosa, WI, USA), and system-2 (Aixplorer US system, SuperSonic Imagine, Aix-en-Provence, France). Qualitative and quantitative parameters including color sign, the maximum elasticity modulus values (E-max), the mean elasticity modulus values (E-mean) and standard deviation (E-sd) of elasticity modulus values in two 2D-SWE systems were analyzed. The diagnostic performance between system-1 and system-2 were evaluated in terms of the areas under the receiver operating characteristic curves (AUROCs). RESULTS: Among the 84 lesions in this study, 66 (78.6%) were benign and 18 (21.4%) were malignant. E-max in system-1 showed the best diagnostic performance with a cut-off value of 174.5 kPa with the associated sensitivity and specificity of 100.0% and 80.3% respectively. Meanwhile, E-sd in system-2 displayed the best diagnostic performance with a cut-off value of 12.7 kPa, with the associated sensitivity and specificity of 94.4% and 80.3% respectively. The diagnostic performance of the two 2D-SWE systems was not statistically different according to ROC analysis of E-max, E-mean, and E-sd. CONCLUSION: For identifying breast lesions, system-1 and system-2 appear to be similar in diagnostic performance. However, different cut-off values for different parameters might be selected to obtain the best diagnostic performance for the two 2D-SWE systems.
Collapse
Affiliation(s)
- Ji-Feng Yu
- Department of Medical Ultrasound, Shanghai Tenth Hospital, School of Clinical Medicine of Nanjing Medical University, Shanghai, P.R. China
- Department of Medical Ultrasound, Center of Minimally Invasive Treatment for Tumor, Shanghai Tenth People’s Hospital; Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University. Shanghai, P.R. China
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment; National Clinical Research Center for Interventional Medicine, Shanghai, P.R. China
| | - Shen Zhang
- Department of Medical Ultrasound, Shanghai Tenth Hospital, School of Clinical Medicine of Nanjing Medical University, Shanghai, P.R. China
- Department of Medical Ultrasound, Center of Minimally Invasive Treatment for Tumor, Shanghai Tenth People’s Hospital; Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University. Shanghai, P.R. China
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment; National Clinical Research Center for Interventional Medicine, Shanghai, P.R. China
| | - Hao-Hao Yin
- Department of Medical Ultrasound, Center of Minimally Invasive Treatment for Tumor, Shanghai Tenth People’s Hospital; Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University. Shanghai, P.R. China
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment; National Clinical Research Center for Interventional Medicine, Shanghai, P.R. China
| | - Bang-Guo Zhou
- Department of Medical Ultrasound, Center of Minimally Invasive Treatment for Tumor, Shanghai Tenth People’s Hospital; Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University. Shanghai, P.R. China
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment; National Clinical Research Center for Interventional Medicine, Shanghai, P.R. China
| | - Yin-Ying Pu
- Department of Medical Ultrasound, Center of Minimally Invasive Treatment for Tumor, Shanghai Tenth People’s Hospital; Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University. Shanghai, P.R. China
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment; National Clinical Research Center for Interventional Medicine, Shanghai, P.R. China
| | - Yan Fang
- Department of Medical Ultrasound, Center of Minimally Invasive Treatment for Tumor, Shanghai Tenth People’s Hospital; Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University. Shanghai, P.R. China
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment; National Clinical Research Center for Interventional Medicine, Shanghai, P.R. China
| | - Dou Du
- Department of Medical Ultrasound, Center of Minimally Invasive Treatment for Tumor, Shanghai Tenth People’s Hospital; Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University. Shanghai, P.R. China
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment; National Clinical Research Center for Interventional Medicine, Shanghai, P.R. China
| | - Yan Zhang
- Department of Medical Ultrasound, Center of Minimally Invasive Treatment for Tumor, Shanghai Tenth People’s Hospital; Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University. Shanghai, P.R. China
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment; National Clinical Research Center for Interventional Medicine, Shanghai, P.R. China
| | - Hui-Xiong Xu
- Department of Medical Ultrasound, Shanghai Tenth Hospital, School of Clinical Medicine of Nanjing Medical University, Shanghai, P.R. China
- Department of Medical Ultrasound, Center of Minimally Invasive Treatment for Tumor, Shanghai Tenth People’s Hospital; Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University. Shanghai, P.R. China
- Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment; National Clinical Research Center for Interventional Medicine, Shanghai, P.R. China
| |
Collapse
|
37
|
Yao R, Zhang Y, Wu K, Li Z, He M, Fengyue B. Quantitative assessment for characterization of breast lesion tissues using adaptively decomposed ultrasound RF images. Biomed Signal Process Control 2022. [DOI: 10.1016/j.bspc.2022.103559] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
|
38
|
Luo H, Li J, Shi Y, Xiao X, Wang Y, Wei Z, Xu J. Stiffness in breast masses with posterior acoustic shadowing: significance of ultrasound real time shear wave elastography. BMC Med Imaging 2022; 22:71. [PMID: 35430798 PMCID: PMC9013446 DOI: 10.1186/s12880-022-00797-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Accepted: 04/11/2022] [Indexed: 11/16/2022] Open
Abstract
Background To assess the stiffness of benign breast masses in ultrasound images with posterior acoustic shadowing (PAS) and malignant lesions, and explore the significance of differential diagnosis using ultrasound real time shear wave elastography. Material and methods All 117 mammary masses (98 patients) with PAS were assessed by using routine ultrasound examination, and elastic modulus values were obtained with the real time shear wave elastography mode. All breast lesions were confirmed by surgery or biopsy. The significance of differences in ultrasound elastography values between breast benign and malignant masses with posterior acoustic shadowing was assessed, and the ROC curves of elasticity modulus values were analyzed. Results Among the 117 masses, 72 were benign and 45 were malignant. The two types of breast masses showed significant differences in size, margin, internal echo, calcification, and blood flow characteristics (P < 0.05), although the difference in orientation was not significant (P > 0.05). Emean, Emax and Esd obtained with real time shear wave elastography showed statistically significant differences between benign masses with posterior acoustic shadowing and breast cancer (P < 0.05), while Emin showed no significant difference between them (P = 0.633). Ultrasound real time shear wave elastography showed higher sensitivity and specificity than conventional ultrasound. Conclusions Benign and malignant breast masses with PAS show different ultrasound manifestations. Real time shear wave elastography can facilitate the differential diagnosis and treatment planning for these breast masses.
Collapse
|
39
|
Duan Y, Zhu Y, Nie F, Guan L, Jia Y, Chen K, Wang W. Predictive value of combining clinicopathological, multimodal ultrasonic characteristics in axillary lymph nodal metastasis burden of patients with cT1-2N0 breast cancer. Clin Hemorheol Microcirc 2022; 81:255-269. [PMID: 35342081 DOI: 10.3233/ch-221398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVE Since the ACOSOG Z0011 trial, the clinical examination of axillary lymph node-negative early breast cancer patients (cT1-2N0) can be used to predict the burden of axillary lymph nodes (ALNs) by axillary ultrasound (AUS). To improving diagnosis of axillary lymph node metastasis (ALNM), we assessed the value of combining clinicopathological, conventional ultrasound, SWE features in the cT1-2N0 breast cancer patients. METHODS Retrospective analysis of 285 patients with cT1-2N0 breast cancer who underwent preoperative ultrasound examination of the lesion and axillary, with shear wave elastography (SWE) of the lesions. According to the postoperative pathological results, they were divided into ≤2 metastatic ALNs group (low nodal burden, LNB) and > 2 metastatic ALNs group (high nodal burden, HNB). Binary logistic regression analysis was used to screen independent risk factors and establish prediction models. The best cut-off value of continuous variables is determined by the receiver operating characteristic curve, and the performance of the prediction model is evaluated. RESULTS Presence of lymphovascular invasion (OR = 7.966, P = 0.010), tumor size (OR = 2.485, P = 0.019), Emean of intratumor (OR = 0.939, P = 0.002) and cortical thickness of lymph node (OR = 9.277, P < 0.001) were independent risk predictors for HNB of cT1-2N0 Group. The predictive model of combined method had better performance in predicting HNB of cT1-2N0 compared with models based on SWE and conventional ultrasound alone (area under the curve: 0.824 vs 0.658, P < 0.001; 0.824 vs 0.789, P = 0.035). CONCLUSIONS The predictive models of combined method obtained from significant clinicopathological and ultrasonographic features can potentially improve the diagnosis and individual treatment of ALNM in patients with cT1-2N0 breast cancer.
Collapse
Affiliation(s)
- Ying Duan
- Department of Ultrasound, Lanzhou University Second Hospital, Lanzhou, China.,Department of Ultrasound, Gansu Cancer Hospital, Lanzhou, China
| | - Yangyang Zhu
- Department of Ultrasound, Lanzhou University Second Hospital, Lanzhou, China
| | - Fang Nie
- Department of Ultrasound, Lanzhou University Second Hospital, Lanzhou, China
| | - Ling Guan
- Department of Ultrasound, Gansu Cancer Hospital, Lanzhou, China
| | - Yingying Jia
- Department of Ultrasound, Lanzhou University Second Hospital, Lanzhou, China
| | - Kundi Chen
- Department of Ultrasound, Lanzhou University Second Hospital, Lanzhou, China
| | - Weili Wang
- Department of Ultrasound, Gansu Cancer Hospital, Lanzhou, China
| |
Collapse
|
40
|
Zhang H, Dong Y, Jia X, Zhang J, Li Z, Chuan Z, Xu Y, Hu B, Huang Y, Chang C, Xu J, Dong F, Xia X, Wu C, Hu W, Wu G, Li Q, Chen Q, Deng W, Jiang Q, Mou Y, Yan H, Xu X, Yan H, Zhou P, Shao Y, Cui L, He P, Qian L, Liu J, Shi L, Zhao Y, Xu Y, Song Y, Zhan W, Zhou J. Comprehensive Risk System Based on Shear Wave Elastography and BI-RADS Categories in Assessing Axillary Lymph Node Metastasis of Invasive Breast Cancer—A Multicenter Study. Front Oncol 2022; 12:830910. [PMID: 35359391 PMCID: PMC8960926 DOI: 10.3389/fonc.2022.830910] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Accepted: 02/14/2022] [Indexed: 12/07/2022] Open
Abstract
Purpose To develop a risk stratification system that can predict axillary lymph node (LN) metastasis in invasive breast cancer based on the combination of shear wave elastography (SWE) and conventional ultrasound. Materials and Methods A total of 619 participants pathologically diagnosed with invasive breast cancer underwent breast ultrasound examinations were recruited from a multicenter of 17 hospitals in China from August 2016 to August 2017. Conventional ultrasound and SWE features were compared between positive and negative LN metastasis groups. The regression equation, the weighting, and the counting methods were used to predict axillary LN metastasis. The sensitivity, specificity, and the areas under the receiver operating characteristic curve (AUC) were calculated. Results A significant difference was found in the Breast Imaging Reporting and Data System (BI-RADS) category, the “stiff rim” sign, minimum elastic modulus of the internal tumor and peritumor region of 3 mm between positive and negative LN groups (p < 0.05 for all). There was no significant difference in the diagnostic performance of the regression equation, the weighting, and the counting methods (p > 0.05 for all). Using the counting method, a 0–4 grade risk stratification system based on the four characteristics was established, which yielded an AUC of 0.656 (95% CI, 0.617–0.693, p < 0.001), a sensitivity of 54.60% (95% CI, 46.9%–62.1%), and a specificity of 68.99% (95% CI, 64.5%–73.3%) in predicting axillary LN metastasis. Conclusion A 0–4 grade risk stratification system was developed based on SWE characteristics and BI-RADS categories, and this system has the potential to predict axillary LN metastases in invasive breast cancer.
Collapse
Affiliation(s)
- Huiting Zhang
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Yijie Dong
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Xiaohong Jia
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Jingwen Zhang
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Zhiyao Li
- Department of Medical Ultrasound, Yunnan Cancer Hospital & The Third Affiliated Hospital of Kunming Medical University, Kunming, China
| | - Zhirui Chuan
- Department of Medical Ultrasound, Yunnan Cancer Hospital & The Third Affiliated Hospital of Kunming Medical University, Kunming, China
| | - Yanjun Xu
- Department of Ultrasound in Medicine, Shanghai Jiao Tong University Affiliated Sixth People’s Hospital, Shanghai Institute of Ultrasound in Medicine, Shanghai, China
| | - Bin Hu
- Department of Ultrasound, Minhang Hospital, Fudan University, Shanghai, China
| | - Yunxia Huang
- Department of Ultrasonography, Fudan University Shanghai Cancer Center, Shanghai Medical College, Fudan University, Shanghai, China
| | - Cai Chang
- Department of Ultrasonography, Fudan University Shanghai Cancer Center, Shanghai Medical College, Fudan University, Shanghai, China
| | - Jinfeng Xu
- Department of Ultrasound, Shenzhen People’s Hospital, The Second Clinical Medical College, Jinan University, and The First Affiliated Hospital, Southern University of Science and Technology, Shenzhen, China
| | - Fajin Dong
- Department of Ultrasound, Shenzhen People’s Hospital, The Second Clinical Medical College, Jinan University, and The First Affiliated Hospital, Southern University of Science and Technology, Shenzhen, China
| | - Xiaona Xia
- Department of Ultrasound Medicine, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, China
| | - Chengrong Wu
- Department of Ultrasound Medicine, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, China
| | - Wenjia Hu
- Department of Ultrasound, People’s Hospital of Henan Province, Zhengzhou, China
| | - Gang Wu
- Department of Ultrasound, People’s Hospital of Henan Province, Zhengzhou, China
| | - Qiaoying Li
- Department of Ultrasound Diseases, Tangdu Hospital, Four Military Medical University, Xi’an, China
| | - Qin Chen
- Department of Ultrasound, Sichuan Provincial People’s Hospital, University of Electronic Science and Technology of China, Chengdu, China
| | - Wanyue Deng
- Department of Ultrasound, Sichuan Provincial People’s Hospital, University of Electronic Science and Technology of China, Chengdu, China
| | - Qiongchao Jiang
- Department of Ultrasound, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Yonglin Mou
- Department of Ultrasound, General Hospital of Northern Theater Command, Shenyang, China
| | - Huannan Yan
- Department of Ultrasound, General Hospital of Northern Theater Command, Shenyang, China
| | - Xiaojing Xu
- Department of Ultrasound, Affiliated Hangzhou First People’s Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Hongju Yan
- Department of Ultrasound, Affiliated Hangzhou First People’s Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Ping Zhou
- Department of Ultrasound, The Third Xiangya Hospital of Central South University, Changsha, China
| | - Yang Shao
- Department of Ultrasound, The Third Xiangya Hospital of Central South University, Changsha, China
| | - Ligang Cui
- Department of Ultrasound, Peking University Third Hospital, Beijing, China
| | - Ping He
- Department of Ultrasound, Peking University Third Hospital, Beijing, China
| | - Linxue Qian
- Department of Ultrasound, Beijing Friendship Hospital, Capital Medical University, Beijing, China
| | - Jinping Liu
- Department of Ultrasound, Beijing Friendship Hospital, Capital Medical University, Beijing, China
| | - Liying Shi
- Department of Ultrasound, Affiliated Hospital of Guizhou Medical University, Guizhou, China
| | - Yanan Zhao
- Department of Ultrasound, Second Affiliated Hospital of Zhejiang University, School of Medicine, Hangzhou, China
| | - Yongyuan Xu
- Department of Ultrasound, Second Affiliated Hospital of Zhejiang University, School of Medicine, Hangzhou, China
| | - Yanyan Song
- Department of Biostatistics, Institute of Medical Sciences, Shanghai Jiaotong University School of Medicine, Shanghai, China
- *Correspondence: Jianqiao Zhou, ; Yanyan Song, ; Weiwei Zhan,
| | - Weiwei Zhan
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
- *Correspondence: Jianqiao Zhou, ; Yanyan Song, ; Weiwei Zhan,
| | - Jianqiao Zhou
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
- *Correspondence: Jianqiao Zhou, ; Yanyan Song, ; Weiwei Zhan,
| |
Collapse
|
41
|
Gu JH, He C, Zhao QY, Jiang TA. Usefulness of new shear wave elastography in early predicting the efficacy of neoadjuvant chemotherapy for patients with breast cancer: where and when to measure is optimal? Breast Cancer 2022; 29:478-486. [PMID: 35038129 DOI: 10.1007/s12282-021-01327-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Accepted: 12/22/2021] [Indexed: 11/02/2022]
Abstract
BACKGROUND The aim of this study was to investigate the diagnosis performance of new shear wave elastography (sound touch elastography, STE) in the prediction of neoadjuvant chemotherapy (NAC) response at an early stage in breast cancer patients and to determine the optimal measurement locations around the lesion in different ranges. METHODS One hundred and eight patients were analyzed in this prospective study from November 2018 to December 2020. All patients completed NAC treatment and underwent STE examination at three time points [the day before NAC (t0); the day before the second course (t1); the day before third course (t2)]. The stiffness of the whole lesion (G), 1-mm shell (S1) and 2-mm shell (S2) around the lesion was expressed by STE parameters. The relative changes (∆stiffness) of STE parameters after the first and second course of NAC were calculated and shown as the variables [Δ(t1) and Δ(t2)]. The diagnostic accuracy of STE was evaluated by means of receiver operating characteristic curve analysis. RESULTS The ∆stiffness (%) including ∆Gmean(t2), ∆S1mean(t2) and ∆S2mean(t2) all showed significant differences between pathological complete response (pCR) and non-pCR groups. ∆S2mean(t2) displayed the best predictive performance for pCR (AUC = 0.842) with an ideal ∆stiffness threshold value - 26%. CONCLUSIONS Measuring the relative changes in the stiffness of surrounding tissue or entire lesion with STE holds promise for effectively predicting the response to NAC at its early stage for breast cancer patients and ∆stiffness of shell 2 mm after the second course of NAC may be a potential prediction parameter.
Collapse
Affiliation(s)
- Jiong-Hui Gu
- Department of Ultrasound, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, 310003, Zhejiang, People's Republic of China
| | - Chang He
- Department of Ultrasound, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, 310003, Zhejiang, People's Republic of China
| | - Qi-Yu Zhao
- Department of Ultrasound, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, 310003, Zhejiang, People's Republic of China
| | - Tian-An Jiang
- Department of Ultrasound, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, 310003, Zhejiang, People's Republic of China.
| |
Collapse
|
42
|
Jia W, Yang Z, Zhang X, Dong Y, Jia X, Zhou J. Shear wave elastography and pulsed doppler for breast lesions: Similar diagnostic performance and positively correlated stiffness and blood flow resistance. Eur J Radiol 2022; 147:110149. [PMID: 35007981 DOI: 10.1016/j.ejrad.2021.110149] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Revised: 12/11/2021] [Accepted: 12/30/2021] [Indexed: 12/24/2022]
Abstract
PURPOSE To compare the diagnostic performance of shear wave elastography (SWE) and pulsed Doppler ultrasound in breast lesions, and to explore whether the quantitative SWE parameters correlated with pulsed Doppler ultrasound parameters. MATERIALS AND METHODS Seventy-nine patients with 79 breast lesions who had undergone conventional ultrasound, pulsed Doppler ultrasound and SWE examination were included. All of them underwent core needle biopsy or surgery within one week. Parameters including Emax (the maximum elastic modulus), Emean (mean elastic modulus), Emin (minimum elastic modulus), Esd (elastic modulus standard deviation), and RI (resistive index), PI (pulsatility index), PSV (peak systolic velocity) and EDV (end diastolic velocity) were obtained for statistical analysis. RESULTS Almost all SWE parameters were significantly different between benign and malignant breast lesions (P<0.05). There was no significant difference between Esd and PI (P>0.05), which had the best AUC among SWE and vascular parameters respectively (0.877 vs. 0.871). Emax showed a moderate correlation with PI (P = 0.000, r = 0.552) and RI (P = 0.000, r = 0.544), and Esd moderately correlated with PI (P = 0.000, r = 0.567) and RI (P = 0.000, r = 0.546). For the benign group, no parameters showed any significant correlation (P>0.05), while for the malignant group, Emax and Esd also significantly correlated with PI or RI. CONCLUSIONS SWE and pulsed Doppler ultrasound had similar diagnostic efficacy for breast lesions. SWE and pulsed Doppler parameters were significantly correlated in breast lesions, especially in malignant ones, indicating the potential association between elastographic and vascular characteristics of breast tumors.
Collapse
Affiliation(s)
- WanRu Jia
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200025, China
| | - ZhiFang Yang
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200025, China
| | - XiaoXiao Zhang
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200025, China
| | - YiJie Dong
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200025, China
| | - XiaoHong Jia
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200025, China.
| | - JianQiao Zhou
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200025, China.
| |
Collapse
|
43
|
Tay IWM, Sim LSJ, Moey THL, Tan KPP, Lai LMS, Leong LCH. Shear wave versus strain elastography of breast lesions-The value of incorporating boundary tissue assessment. Clin Imaging 2021; 82:228-233. [PMID: 34902798 DOI: 10.1016/j.clinimag.2021.11.030] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Revised: 11/20/2021] [Accepted: 11/27/2021] [Indexed: 01/31/2023]
Abstract
PURPOSE This prospective study compares the diagnostic performance of strain elastography (SE) based on the elastogram to B-mode (E/B) size ratio to shear-wave elastography (SWE) incorporating assessment of boundary tissue stiffness. METHODS In this prospective study, 81 women consented to undergo ultrasound (US) elastographic assessment prior to biopsy of their mass(es). A total of 101 masses were evaluated with SE and SWE using a single machine (Siemens Acuson S2000). The histopathologic diagnosis was used as the reference standard. The sensitivity, specificity and area under curve (AUC) were obtained for SE and SWE. RESULTS The sensitivity and specificity of SE using the E/B ratio was 94.7% (95% CI: 87.6 100) and 81.0% (95% CI: 71.3 90.1) respectively. For SWE the sensitivity and specificity was 73.7% (95% CI: 59.7 87.7) and 82.5% (95% CI: 73.2 91.9) respectively. The AUC for SE was higher (0.878) compared to SWE (0.697). CONCLUSION SE elastography using the E/B ratio yields diagnostic performance which is superior to SWE incorporating assessment of peripheral stiffness.
Collapse
Affiliation(s)
- Ian Wei Ming Tay
- Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, 169608, Singapore.
| | - Llewellyn Shao-Jen Sim
- Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, 169608, Singapore.
| | - Tammy Hui Lin Moey
- Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, 169608, Singapore.
| | - Karen Pei Pei Tan
- Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, 169608, Singapore.
| | - Lily Mei San Lai
- Department of Diagnostic Radiology, National Cancer Centre Singapore, Outram Road, 169608, Singapore.
| | - Lester Chee Hao Leong
- Department of Diagnostic Radiology, National Cancer Centre Singapore, Outram Road, 169608, Singapore.
| |
Collapse
|
44
|
Duric N, Sak M, Littrup PJ. The Potential Role of the Fat-Glandular Interface (FGI) in Breast Carcinogenesis: Results from an Ultrasound Tomography (UST) Study. J Clin Med 2021; 10:5615. [PMID: 34884317 PMCID: PMC8658427 DOI: 10.3390/jcm10235615] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Revised: 11/18/2021] [Accepted: 11/23/2021] [Indexed: 11/29/2022] Open
Abstract
This study explored the relationship between the extent of the fat-glandular interface (FGI) and the presence of malignant vs. benign lesions. Two hundred and eight patients were scanned with ultrasound tomography (UST) as part of a Health Insurance Portability and Accountability Act (HIPAA)-compliant study. Segmentation of the sound speed images, employing the k-means clustering method, was used to help define the extent of the FGI for each patient. The metric, α, was defined as the surface area to volume ratio of the segmented fibroglandular volume and its mean value across patients was determined for cancers, fibroadenomas and cysts. ANOVA tests were used to assess significance. The means and standard deviations of α for cancers, fibroadenomas and cysts were found to be 4.0 ± 2.0 cm-1, 3.1 ± 1.7 cm-1 and 2.3 ± 0.9 cm-1, respectively. The differences were statistically significant (p < 0.001). The separation between the groups increased when α was measured on only the image slice where the finding was most prominent, with values for cancers, fibroadenomas and cysts of 5.4 ± 3.6 cm-1, 3.6 ± 2.3 cm-1 and 2.4 ± 1.5 cm-1, respectively. Of the three types of masses studied, cancer was associated with the most extensive FGIs, suggesting a potential role for the FGI in carcinogenesis, a subject for future studies.
Collapse
Affiliation(s)
- Nebojsa Duric
- Department of Imaging Sciences, University of Rochester, Rochester, NY 14642, USA
- Delphinus Medical Technologies Inc., Novi, MI 48374, USA;
| | - Mark Sak
- School of Medicine, Wayne State University, Detroit, MI 48202, USA;
| | - Peter J. Littrup
- Delphinus Medical Technologies Inc., Novi, MI 48374, USA;
- School of Medicine, Wayne State University, Detroit, MI 48202, USA;
| |
Collapse
|
45
|
Zhang YX, Xue JP, Li HZ, Miao JW, Kang CS. Clinical Value of Shear Wave Elastography Color Scores in Classifying Thyroid Nodules. Int J Gen Med 2021; 14:8007-8018. [PMID: 34785943 PMCID: PMC8590981 DOI: 10.2147/ijgm.s331406] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Accepted: 10/19/2021] [Indexed: 11/23/2022] Open
Abstract
Objective To evaluate the clinical value of qualitative shear wave elastography (SWE) color in the differential diagnosis of benign and malignant thyroid nodules. Methods From January 2017 to July 2018, 241 patients with 261 thyroid nodules, who underwent conventional ultrasonography and SWE examination before surgical resection, were enrolled. The nodules were also evaluated by histopathologic analyses. The SWE color characteristics that could differentiate malignant and benign thyroid nodules were selected and scored based on the malignancy rate. The diagnostic performances were evaluated by receiver operating characteristic (ROC) curves analysis. Results Among the 261 thyroid nodules, 58 were benign, and 203 were malignant. Malignancy was associated with orange or red as the color of maximum hardness inside a nodule, green as the primary color, with a “stiff rim,” inhomogeneous internal color, and inhomogeneous color between the nodules and its surrounding areas. The SWE color scores for benign thyroid nodules were mainly 0 and 1, while 4 and 5 were for malignant thyroid nodules. The area under the ROC curve (AUC) of the SWE color score ≥3 for the diagnosis of malignant thyroid nodules was 0.828 (95% CI: 0.764, 0.891) with a sensitivity of 82.8%, a specificity of 82.8%, and an accuracy of 83.1%. Additionally, conventional ultrasound combined with SWE color scores had a higher diagnostic performance than conventional ultrasound (AUC 0.820 vs AUC 0.796, P = 0.04). Conclusion The SWE color scores might be a convenient and effective method to assist in differentiating thyroid nodules.
Collapse
Affiliation(s)
- Yan-Xia Zhang
- Department of Ultrasonography, Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Taiyuan, 030032, People's Republic of China
| | - Ji-Ping Xue
- Department of Ultrasonography, Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Taiyuan, 030032, People's Republic of China
| | - Hui-Zhan Li
- Department of Ultrasonography, Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Taiyuan, 030032, People's Republic of China
| | - Jun-Wang Miao
- Department of Ultrasonography, Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Taiyuan, 030032, People's Republic of China
| | - Chun-Song Kang
- Department of Ultrasonography, Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Taiyuan, 030032, People's Republic of China
| |
Collapse
|
46
|
Napoli ME, Goswami S, McAleavey SA, Doyley MM, Howard TM. Enabling quantitative robot-assisted compressional elastography via the extended Kalman filter. Phys Med Biol 2021; 66. [PMID: 34715685 DOI: 10.1088/1361-6560/ac34b0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Accepted: 10/29/2021] [Indexed: 11/12/2022]
Abstract
Compressional or quasi-static elastography has demonstrated the capability to detect occult cancers in a variety of tissue types, however it has a serious limitation in that the resulting elastograms are generally qualitative whereas other forms of elastography, such as shear-wave, can produce absolute measures of elasticity for histopathological classification. We address this limitation by introducing a stochastic method using an extended Kalman filter and robot-assistance to obtain quantitative elastograms which are resilient to measurement noise and system uncertainty. In this paper, the probabilistic framework is described, which utilizes many ultrasound acquisitions obtained from multiple palpations, to fuse data and uncertainty from a robotic manipulator's joint encoders and force/torque sensor directly into the inverse reconstruction of the elastogram. Quantitative results are demonstrated over homogeneous and inclusion gelatin phantoms using a seven degree of freedom manipulator for a range of initial elasticity assumptions. Results imply resilience to poorly assumed initial conditions as all trials were within 5 kPa of the elasticity measured by a mechanical testing system. Moreover, the presence or absence of an inclusion is clear in all reconstructed elastograms even when artifacts are present in displacement fields, indicating further robustness to measurement noise. The proposed stochastic method allows fusion of data from a robot's sensors directly into compressional elastography image reconstruction which may stabilize optimization and improve accuracy. This approach provides a mathematical framework to readily incorporate measurements from additional sensors in future applications which may extend the capabilities of compressional elastography beyond that of producing quantitative elasticity measurements.
Collapse
Affiliation(s)
- Michael E Napoli
- University of Rochester, Rochester, NY, United States of America
| | - Soumya Goswami
- University of Rochester, Rochester, NY, United States of America
| | | | - Marvin M Doyley
- University of Rochester, Rochester, NY, United States of America
| | - Thomas M Howard
- University of Rochester, Rochester, NY, United States of America
| |
Collapse
|
47
|
Huang Y, Liu Y, Wang Y, Zheng X, Han J, Li Q, Hu Y, Mao R, Zhou J. Quantitative analysis of shear wave elastic heterogeneity for prediction of lymphovascular invasion in breast cancer. Br J Radiol 2021; 94:20210682. [PMID: 34478333 DOI: 10.1259/bjr.20210682] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE To evaluate the correlation between elastic heterogeneity (EH) and lymphovascular invasion (LVI) in breast cancers and assess the clinical value of using EH to predict LVI pre-operatively. METHODS This retrospective study consisted of 376 patients with breast cancers that had undergone shear wave elastography (SWE) with virtual touch tissue imaging quantification between June 2017 and June 2018. The EH was determined as the difference between the averaged three highest and three lowest shear wave value. Clinicalpathological parameters including histological type and grades, LVI, axillary lymph node status and molecular markers (estrogen receptor, progesterone receptor, human epidermal growth factor receptor 2 and Ki-67) were reviewed and recorded. Relationship EH and clinicalpathological parameters was investigated respectively. The diagnostic performance of EH in distinguishing LVI or not was analyzed. RESULTS At multivariate regression analysis, only EH (p = 0.017) was positively correlated with LVI in all tumors. EH (p = 0.003) and Ki-67 (p = 0.025) were positively correlated with LVI in tumors ≤ 2 cm. None of clinicalpathological parameters were correlated with LVI in tumors > 2 cm (p > 0.05 for all). Using EH to predict LVI in tumors ≤ 2 cm, the sensitivity and negative predictive value were 93 and 89% respectively. CONCLUSION EH has the potential to be served as an imaging biomarker to predict LVI in breast cancer especially for tumors ≤ 2 cm. ADVANCES IN KNOWLEDGE There was no association between LVI and other most commonly used elastic features such as SWVmean and SWVmax. Elastic heterogeneity is an independent predictor of LVI, so it can provide additional prognostic information for routine preoperative breast cancer assessment.For tumors ≤ 2cm, using EH value higher than 1.36 m/s to predict LVI involvement, the sensitivity and negative predictive value can reach to 93% and 89%, respectively, suggesting that breast cancer with negative EH value was more likely to be absent of LVI.
Collapse
Affiliation(s)
- Yini Huang
- Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong, China
| | - Yubo Liu
- Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong, China
| | - Yun Wang
- Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong, China
| | - Xueyi Zheng
- Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong, China
| | - Jing Han
- Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong, China
| | - Qian Li
- Department of Ultrasound, Affiliated Tumor Hospital of Zhengzhou University, Zhengzhou, China
| | - Yixin Hu
- Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong, China
| | - Rushuang Mao
- Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong, China
| | - Jianhua Zhou
- Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong, China
| |
Collapse
|
48
|
Jiang M, Li CL, Luo XM, Chuan ZR, Chen RX, Tang SC, Lv WZ, Cui XW, Dietrich CF. Radiomics model based on shear-wave elastography in the assessment of axillary lymph node status in early-stage breast cancer. Eur Radiol 2021; 32:2313-2325. [PMID: 34671832 DOI: 10.1007/s00330-021-08330-w] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 08/12/2021] [Accepted: 09/13/2021] [Indexed: 11/26/2022]
Abstract
OBJECTIVES To develop and validate an ultrasound elastography radiomics nomogram for preoperative evaluation of the axillary lymph node (ALN) burden in early-stage breast cancer. METHODS Data of 303 patients from hospital #1 (training cohort) and 130 cases from hospital #2 (external validation cohort) between Jun 2016 and May 2019 were enrolled. Radiomics features were extracted from shear-wave elastography (SWE) and corresponding B-mode ultrasound (BMUS) images. The minimum redundancy maximum relevance and least absolute shrinkage and selection operator algorithms were used to select ALN status-related features. Proportional odds ordinal logistic regression was performed using the radiomics signature together with clinical data, and an ordinal nomogram was subsequently developed. We evaluated its performance using C-index and calibration. RESULTS SWE signature, US-reported LN status, and molecular subtype were independent risk factors associated with ALN status. The nomogram based on these variables showed good discrimination in the training (overall C-index: 0.842; 95%CI, 0.773-0.879) and the validation set (overall C-index: 0.822; 95%CI, 0.765-0.838). For discriminating between disease-free axilla (N0) and any axillary metastasis (N + (≥ 1)), it achieved a C-index of 0.845 (95%CI, 0.777-0.914) for the training cohort and 0.817 (95%CI, 0.769-0.865) for the validation cohort. The tool could also discriminate between low (N + (1-2)) and heavy metastatic ALN burden (N + (≥ 3)), with a C-index of 0.827 (95%CI, 0.742-0.913) in the training cohort and 0.810 (95%CI, 0.755-0.864) in the validation cohort. CONCLUSION The radiomics model shows favourable predictive ability for ALN staging in patients with early-stage breast cancer, which could provide incremental information for decision-making. KEY POINTS • Radiomics analysis helps radiologists to evaluate the axillary lymph node status of breast cancer with accuracy. • This multicentre retrospective study showed that radiomics nomogram based on shear-wave elastography provides incremental information for risk stratification. • Treatment can be given with more precision based on the model.
Collapse
Affiliation(s)
- Meng Jiang
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei Province, China
| | - Chang-Li Li
- Department of Geratology, Hubei Provincial Hospital of Integrated Chinese and Western Medicine, 11 Lingjiaohu Avenue, Wuhan, 430015, China
| | - Xiao-Mao Luo
- Department of Medical Ultrasound, Yunnan Cancer Hospital & The Third Affiliated Hospital of Kunming Medical University, Kunming, 650118, China.
| | - Zhi-Rui Chuan
- Department of Medical Ultrasound, Yunnan Cancer Hospital & The Third Affiliated Hospital of Kunming Medical University, Kunming, 650118, China
| | - Rui-Xue Chen
- Department of Medical Ultrasound, Wuchang Hospital, Wuhan, 430030, China
| | - Shi-Chu Tang
- Department of Medical Ultrasound, Hunan Cancer Hospital/The Affiliated Cancer Hospital of Xiangya School of Medicine, Central South University, Changsha, 410013, Hunan, China
| | - Wen-Zhi Lv
- Department of Artificial Intelligence, Julei Technology, Wuhan, 430030, China
| | - Xin-Wu Cui
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei Province, China.
| | - Christoph F Dietrich
- Department of Internal Medicine, Hirslanden Clinic, Schänzlihalde 11, 3013, Bern, Switzerland
| |
Collapse
|
49
|
Littrup PJ, Duric N, Sak M, Li C, Roy O, Brem RF, Yamashita M. The Fat-glandular Interface and Breast Tumor Locations: Appearances on Ultrasound Tomography Are Supported by Quantitative Peritumoral Analyses. JOURNAL OF BREAST IMAGING 2021; 3:455-464. [PMID: 38424790 DOI: 10.1093/jbi/wbab032] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Indexed: 03/02/2024]
Abstract
OBJECTIVE To analyze the preferred tissue locations of common breast masses in relation to anatomic quadrants and the fat-glandular interface (FGI) using ultrasound tomography (UST). METHODS Ultrasound tomography scanning was performed in 206 consecutive women with 298 mammographically and/or sonographically visible, benign and malignant breast masses following written informed consent to participate in an 8-site multicenter, Institutional Review Board-approved cohort study. Mass locations were categorized by their anatomic breast quadrant and the FGI, which was defined by UST as the high-contrast circumferential junction of fat and fibroglandular tissue on coronal sound speed imaging. Quantitative UST mass comparisons were done for each tumor and peritumoral region using mean sound speed and percentage of fibroglandular tissue. Chi-squared and analysis of variance tests were used to assess differences. RESULTS Cancers were noted at the FGI in 95% (74/78) compared to 51% (98/194) of fibroadenomas and cysts combined (P < 0.001). No intra-quadrant differences between cancer and benign masses were noted for tumor location by anatomic quadrants (P = 0.66). Quantitative peritumoral sound speed properties showed that cancers were surrounded by lower mean sound speeds (1477 m/s) and percent fibroglandular tissue (47%), compared to fibroadenomas (1496 m/s; 65.3%) and cysts (1518 m/s; 84%) (P < 0.001; P < 0.001, respectively). CONCLUSION Breast cancers form adjacent to fat and UST localized the vast majority to the FGI, while cysts were most often completely surrounded by dense tissue. These observations were supported by quantitative peritumoral analyses of sound speed values for fat and fibroglandular tissue.
Collapse
Affiliation(s)
- Peter J Littrup
- Departments of Radiology and Oncology, Karmanos Cancer Institute, Detroit, MI, USA
- Department of Oncology, Wayne State University, Detroit, Novi, MI, USA
- Delphinus Medical Technologies, Inc., Novi, MI, USA
| | - Nebojsa Duric
- Departments of Radiology and Oncology, Karmanos Cancer Institute, Detroit, MI, USA
- Department of Oncology, Wayne State University, Detroit, Novi, MI, USA
- Delphinus Medical Technologies, Inc., Novi, MI, USA
| | - Mark Sak
- Delphinus Medical Technologies, Inc., Novi, MI, USA
| | - Cuiping Li
- Delphinus Medical Technologies, Inc., Novi, MI, USA
| | - Olivier Roy
- Delphinus Medical Technologies, Inc., Novi, MI, USA
| | - Rachel F Brem
- The George Washington Cancer Center, George Washington University, Washington, DC, USA
| | - Mary Yamashita
- University of Southern California; Norris Cancer Center and Hospital, Los Angeles, CA, USA
| |
Collapse
|
50
|
Chami L, Giron A, Ezziane M, Leblond V, Charlotte F, Pellot-Barakat C, Lucidarme O. Quantitative and Qualitative Approach for Shear Wave Elastography in Superficial Lymph Nodes. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:2117-2127. [PMID: 34059376 DOI: 10.1016/j.ultrasmedbio.2021.04.008] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Revised: 04/01/2021] [Accepted: 04/10/2021] [Indexed: 06/12/2023]
Abstract
The diagnostic contribution of 2-D shear-wave elastography (SWE) in management of superficial lymph nodes (LNs) of any origin was evaluated in 222 patients referred for needle core biopsy. Each patient underwent conventional B-mode/Doppler ultrasound examinations (conventional ultrasound) and SWE. Quantitative SWE parameters and qualitative SWE map features were extracted. Carcinomas were found to be significantly stiffer than benign LNs (29.5 ± 32.3 kPa vs. 6.7 ± 12.3 kPa). Lymphomas exhibited intermediate stiffness (11.4 ± 5.2 kPa). Qualitative SWE analysis provided color patterns specific to histopathology (stiff rim, nodular and undetermined patterns related to malignancy and blue pattern to benignity). Adding SWE to conventional ultrasound improved the sensitivity of LN diagnosis (from 81.1% to 92.0%) but decreased its specificity (from 73.2% to 67.6%) because of the high prevalence of lymphomas compared with carcinomas. Inter-observer agreement for quantitative SWE was good (intra-class correlation coefficient = 0.82) as was inter-observer diagnostic agreement for qualitative SWE (κ = 0.65). LN location and histology type were found to influence the reported diagnostic performance of SWE.
Collapse
Affiliation(s)
- Linda Chami
- Department of Radiology, Pitié-Salpêtrière Hospital, Sorbonne University, Paris, France; LIB, INSERM, CNRS, UMR7371-U1146, Sorbonne University, Paris, France
| | - Alain Giron
- LIB, INSERM, CNRS, UMR7371-U1146, Sorbonne University, Paris, France
| | - Malek Ezziane
- Department of Radiology, Pitié-Salpêtrière Hospital, Sorbonne University, Paris, France
| | - Véronique Leblond
- Department of Haematology, Pitié-Salpêtrière Hospital, Sorbonne University, Paris, France
| | - Frédéric Charlotte
- Department of Pathology, Pitié-Salpêtrière Hospital, Sorbonne University, Paris, France
| | - Claire Pellot-Barakat
- BioMaps, University Paris-Saclay, CEA, CNRS, INSERM, Service Hospitalier Frédéric Joliot, Orsay, France.
| | - Olivier Lucidarme
- Department of Radiology, Pitié-Salpêtrière Hospital, Sorbonne University, Paris, France; LIB, INSERM, CNRS, UMR7371-U1146, Sorbonne University, Paris, France
| |
Collapse
|