1
|
Klemenz AC, Manzke M, Meinel FG. [Artificial intelligence in cardiovascular radiology : Image acquisition, image reconstruction and workflow optimization]. RADIOLOGIE (HEIDELBERG, GERMANY) 2024:10.1007/s00117-024-01335-8. [PMID: 38913176 DOI: 10.1007/s00117-024-01335-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 06/05/2024] [Indexed: 06/25/2024]
Abstract
BACKGROUND Artificial intelligence (AI) has the potential to fundamentally change radiology workflow. OBJECTIVES This review article provides an overview of AI applications in cardiovascular radiology with a focus on image acquisition, image reconstruction, and workflow optimization. MATERIALS AND METHODS First, established applications of AI are presented for cardiovascular computed tomography (CT) and magnetic resonance imaging (MRI). Building on this, we describe the range of applications that are currently being developed and evaluated. The practical benefits, opportunities, and potential risks of artificial intelligence in cardiovascular imaging are critically discussed. The presentation is based on the relevant specialist literature and our own clinical and scientific experience. RESULTS AI-based techniques for image reconstruction are already commercially available and enable dose reduction in cardiovascular CT and accelerated image acquisition in cardiac MRI. Postprocessing of cardiovascular CT and MRI examinations can already be considerably simplified using established AI-based segmentation algorithms. In contrast, the practical benefits of many AI applications aimed at the diagnosis of cardiovascular diseases are less evident. Potential risks such as automation bias and considerations regarding cost efficiency should also be taken into account. CONCLUSIONS In a market characterized by great expectations and rapid technical development, it is important to realistically assess the practical benefits of AI applications for your own hospital or practice.
Collapse
Affiliation(s)
- Ann-Christin Klemenz
- Universitätsmedizin Rostock, Institut für Diagnostische und Interventionelle Radiologie, Kinder- und Neuroradiologie, Schillingallee 36, 18057, Rostock, Deutschland
| | - Mathias Manzke
- Universitätsmedizin Rostock, Institut für Diagnostische und Interventionelle Radiologie, Kinder- und Neuroradiologie, Schillingallee 36, 18057, Rostock, Deutschland
| | - Felix G Meinel
- Universitätsmedizin Rostock, Institut für Diagnostische und Interventionelle Radiologie, Kinder- und Neuroradiologie, Schillingallee 36, 18057, Rostock, Deutschland.
| |
Collapse
|
2
|
Wajer R, Wajer A, Kazimierczak N, Wilamowska J, Serafin Z. The Impact of AI on Metal Artifacts in CBCT Oral Cavity Imaging. Diagnostics (Basel) 2024; 14:1280. [PMID: 38928694 PMCID: PMC11203150 DOI: 10.3390/diagnostics14121280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2024] [Revised: 06/13/2024] [Accepted: 06/14/2024] [Indexed: 06/28/2024] Open
Abstract
OBJECTIVE This study aimed to assess the impact of artificial intelligence (AI)-driven noise reduction algorithms on metal artifacts and image quality parameters in cone-beam computed tomography (CBCT) images of the oral cavity. MATERIALS AND METHODS This retrospective study included 70 patients, 61 of whom were analyzed after excluding those with severe motion artifacts. CBCT scans, performed using a Hyperion X9 PRO 13 × 10 CBCT machine, included images with dental implants, amalgam fillings, orthodontic appliances, root canal fillings, and crowns. Images were processed with the ClariCT.AI deep learning model (DLM) for noise reduction. Objective image quality was assessed using metrics such as the differentiation between voxel values (ΔVVs), the artifact index (AIx), and the contrast-to-noise ratio (CNR). Subjective assessments were performed by two experienced readers, who rated overall image quality and artifact intensity on predefined scales. RESULTS Compared with native images, DLM reconstructions significantly reduced the AIx and increased the CNR (p < 0.001), indicating improved image clarity and artifact reduction. Subjective assessments also favored DLM images, with higher ratings for overall image quality and lower artifact intensity (p < 0.001). However, the ΔVV values were similar between the native and DLM images, indicating that while the DLM reduced noise, it maintained the overall density distribution. Orthodontic appliances produced the most pronounced artifacts, while implants generated the least. CONCLUSIONS AI-based noise reduction using ClariCT.AI significantly enhances CBCT image quality by reducing noise and metal artifacts, thereby improving diagnostic accuracy and treatment planning. Further research with larger, multicenter cohorts is recommended to validate these findings.
Collapse
Affiliation(s)
- Róża Wajer
- Department of Radiology and Diagnostic Imaging, University Hospital No. 1 in Bydgoszcz, Marii Skłodowskiej—Curie 9, 85-094 Bydgoszcz, Poland; (J.W.); (Z.S.)
| | | | - Natalia Kazimierczak
- Kazimierczak Private Medical Practice, Dworcowa 13/u6a, 85-009 Bydgoszcz, Poland;
| | - Justyna Wilamowska
- Department of Radiology and Diagnostic Imaging, University Hospital No. 1 in Bydgoszcz, Marii Skłodowskiej—Curie 9, 85-094 Bydgoszcz, Poland; (J.W.); (Z.S.)
- Department of Radiology and Diagnostic Imaging, Collegium Medicum, Nicolaus Copernicus University in Torun, Jagiellońska 13-15, 85-067 Bydgoszcz, Poland
| | - Zbigniew Serafin
- Department of Radiology and Diagnostic Imaging, University Hospital No. 1 in Bydgoszcz, Marii Skłodowskiej—Curie 9, 85-094 Bydgoszcz, Poland; (J.W.); (Z.S.)
- Department of Radiology and Diagnostic Imaging, Collegium Medicum, Nicolaus Copernicus University in Torun, Jagiellońska 13-15, 85-067 Bydgoszcz, Poland
| |
Collapse
|
3
|
Quaia E, Kiyomi Lanza de Cristoforis E, Agostini E, Zanon C. Computed Tomography Effective Dose and Image Quality in Deep Learning Image Reconstruction in Intensive Care Patients Compared to Iterative Algorithms. Tomography 2024; 10:912-921. [PMID: 38921946 PMCID: PMC11209234 DOI: 10.3390/tomography10060069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Revised: 06/05/2024] [Accepted: 06/06/2024] [Indexed: 06/27/2024] Open
Abstract
Deep learning image reconstruction (DLIR) algorithms employ convolutional neural networks (CNNs) for CT image reconstruction to produce CT images with a very low noise level, even at a low radiation dose. The aim of this study was to assess whether the DLIR algorithm reduces the CT effective dose (ED) and improves CT image quality in comparison with filtered back projection (FBP) and iterative reconstruction (IR) algorithms in intensive care unit (ICU) patients. We identified all consecutive patients referred to the ICU of a single hospital who underwent at least two consecutive chest and/or abdominal contrast-enhanced CT scans within a time period of 30 days using DLIR and subsequently the FBP or IR algorithm (Advanced Modeled Iterative Reconstruction [ADMIRE] model-based algorithm or Adaptive Iterative Dose Reduction 3D [AIDR 3D] hybrid algorithm) for CT image reconstruction. The radiation ED, noise level, and signal-to-noise ratio (SNR) were compared between the different CT scanners. The non-parametric Wilcoxon test was used for statistical comparison. Statistical significance was set at p < 0.05. A total of 83 patients (mean age, 59 ± 15 years [standard deviation]; 56 men) were included. DLIR vs. FBP reduced the ED (18.45 ± 13.16 mSv vs. 22.06 ± 9.55 mSv, p < 0.05), while DLIR vs. FBP and vs. ADMIRE and AIDR 3D IR algorithms reduced image noise (8.45 ± 3.24 vs. 14.85 ± 2.73 vs. 14.77 ± 32.77 and 11.17 ± 32.77, p < 0.05) and increased the SNR (11.53 ± 9.28 vs. 3.99 ± 1.23 vs. 5.84 ± 2.74 and 3.58 ± 2.74, p < 0.05). CT scanners employing DLIR improved the SNR compared to CT scanners using FBP or IR algorithms in ICU patients despite maintaining a reduced ED.
Collapse
Affiliation(s)
- Emilio Quaia
- Department of Radiology, University of Padova, Via Giustiniani 2, 35128 Padova, Italy
| | | | | | | |
Collapse
|
4
|
Bai K, Wang T, Zhang G, Zhang M, Fu H, Feng Y, Liang K. Improving intracranial aneurysms image quality and diagnostic confidence with deep learning reconstruction in craniocervical CT angiography. Acta Radiol 2024:2841851241258220. [PMID: 38839094 DOI: 10.1177/02841851241258220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2024]
Abstract
BACKGROUND The diagnostic impact of deep learning computed tomography (CT) reconstruction on intracranial aneurysm (IA) remains unclear. PURPOSE To quantify the image quality and diagnostic confidence on IA in craniocervical CT angiography (CTA) reconstructed with DEep Learning Trained Algorithm (DELTA) compared to the routine hybrid iterative reconstruction (HIR). MATERIAL AND METHODS A total of 60 patients who underwent craniocervical CTA and were diagnosed with IA were retrospectively enrolled. Images were reconstructed with DELTA and HIR, where the image quality was first compared in noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Next, two radiologists independently graded the noise appearance, arterial sharpness, small vessel visibility, conspicuity of calcifications that may present in arteries, and overall image quality, each with a 5-point Likert scale. The diagnostic confidence on IAs of various sizes was also graded. RESULTS Significantly lower noise and higher SNR and CNR were found on DELTA than on HIR images (all P < 0.05). All five subjective metrics were scored higher by both readers on the DELTA images (all P < 0.05), with good to excellent inter-observer agreement (κ = 0.77-0.93). DELTA images were rated with higher diagnostic confidence on IAs compared to HIR (P < 0.001), particularly for those with size ≤3 mm, which were scored 4.5 ± 0.6 versus 3.4 ± 0.8 and 4.4 ± 0.7 versus 3.5 ± 0.8 by two readers, respectively. CONCLUSION The DELTA shows potential for improving the image quality and the associated confidence in diagnosing IA that may be worth consideration for routine craniocervical CTA applications.
Collapse
Affiliation(s)
- Kun Bai
- Radiology Department, Jiading District Central Hospital Affiliated to Shanghai University of Medicine & Health Sciences, Key Laboratory of Shanghai Municipal Health Commission for Smart Image, Shanghai, PR China
| | - Tiantian Wang
- Central Research Institute, United Imaging Healthcare, Shanghai, PR China
| | - Guozhi Zhang
- Central Research Institute, United Imaging Healthcare, Shanghai, PR China
| | - Ming Zhang
- Radiology Department, Jiading District Central Hospital Affiliated to Shanghai University of Medicine & Health Sciences, Key Laboratory of Shanghai Municipal Health Commission for Smart Image, Shanghai, PR China
| | - Hongchao Fu
- Radiology Department, Jiading District Central Hospital Affiliated to Shanghai University of Medicine & Health Sciences, Key Laboratory of Shanghai Municipal Health Commission for Smart Image, Shanghai, PR China
| | - Yun Feng
- Radiology Department, Jiading District Central Hospital Affiliated to Shanghai University of Medicine & Health Sciences, Key Laboratory of Shanghai Municipal Health Commission for Smart Image, Shanghai, PR China
| | - Kaiyi Liang
- Radiology Department, Jiading District Central Hospital Affiliated to Shanghai University of Medicine & Health Sciences, Key Laboratory of Shanghai Municipal Health Commission for Smart Image, Shanghai, PR China
| |
Collapse
|
5
|
McLean D, Delfino O, Vozzo M, Moorin R. Estimation of maternal and foetal risk of radiation-induced cancer from a survey of computed tomography pulmonary angiography and ventilation/perfusion lung scanning for diagnosing pulmonary embolism during pregnancy. J Med Imaging Radiat Oncol 2024; 68:385-392. [PMID: 38687690 DOI: 10.1111/1754-9485.13661] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Accepted: 04/05/2024] [Indexed: 05/02/2024]
Abstract
INTRODUCTION While there are many papers on maternal and foetal radiation doses from computed tomography pulmonary angiography (CTPA) and ventilation/perfusion (V/Q) lung scanning examinations for diagnosing pulmonary embolism in pregnant patients, few have used clinical data to examine the patient lifetime attributable risk (LAR) of different cancer types. This paper aims to estimate the cancer risk from maternal radiation doses from CTPA and V/Q examinations and associated foetal doses. METHODS Dosimetric data were determined for 267 pregnant patients who received CTPA and/or V/Q examinations over 8 years. Organ and foetal doses were determined using software allowing patient size variations for CTPA and using two different activity-to-organ dose conversion methods for V/Q scans. The LAR of cancer incidence was estimated using International Commission on Radiological Protection (ICRP) modelling including estimates of detriment. RESULTS Estimated total cancer incidence was 23 and 22 cases per 100,000 for CTPA and V/Q examinations, respectively, with detriment estimates of 18 and 20 cases. Cancer incidence was evenly divided between lung and breast cancer for CTPA with lung cancer being 80% of all cancer for V/Q. The median foetal doses were 0.03 mSv for CTPA and 0.29 mSv for V/Q. Significant differences in estimated foetal dose for V/Q scans were obtained by the two different methods used. The differences in dose between the modes of CTPA scan acquisition highlight the importance of optimisation. CONCLUSION Maternal cancer incidence and detriment were remarkably similar for each examination. Optimisation of examinations is critical for low-dose outcomes, particularly for CTPA examination.
Collapse
Affiliation(s)
- Donald McLean
- Medical Physics and Radiation Engineering, Canberra Health Services, Canberra, Australian Capital Territory, Australia
| | - Olivia Delfino
- Medical Physics and Radiation Engineering, Canberra Health Services, Canberra, Australian Capital Territory, Australia
| | - Marie Vozzo
- Medical Physics and Radiation Engineering, Canberra Health Services, Canberra, Australian Capital Territory, Australia
| | - Rachael Moorin
- Discipline of Health Economics & Data Analytics, Curtin School of Population Health, Faculty of Health Sciences, Curtin University, Perth, Western Australia, Australia
- School of Population and Global Health, The University of Western Australia, Perth, Western Australia, Australia
| |
Collapse
|
6
|
Greffier J, Soyer P, Dabli D. Improving image quality of the middle ear with ultra-high-resolution CT coupled with deep-learning image reconstruction algorithm. Diagn Interv Imaging 2024; 105:211-212. [PMID: 38395667 DOI: 10.1016/j.diii.2024.02.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Accepted: 02/09/2024] [Indexed: 02/25/2024]
Affiliation(s)
- Joël Greffier
- Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Nîmes 30029, France.
| | - Philippe Soyer
- Faculté de Médecine, Université Paris Cité, Paris 75006, France; Department of Radiology, Hopital Cochin, AP-HP, Paris 75014, France
| | - Djamel Dabli
- Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Nîmes 30029, France
| |
Collapse
|
7
|
Klemenz AC, Beckert L, Manzke M, Lang CI, Weber MA, Meinel FG. Influence of Deep Learning Based Image Reconstruction on Quantitative Results of Coronary Artery Calcium Scoring. Acad Radiol 2024; 31:2259-2267. [PMID: 38582685 DOI: 10.1016/j.acra.2024.03.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 03/05/2024] [Accepted: 03/18/2024] [Indexed: 04/08/2024]
Abstract
RATIONALE AND OBJECTIVES To assess the impact of deep learning-based imaging reconstruction (DLIR) on quantitative results of coronary artery calcium scoring (CACS) and to evaluate the potential of DLIR for radiation dose reduction in CACS. METHODS For a retrospective cohort of 100 consecutive patients (mean age 62 ±10 years, 40% female), CACS scans were reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASiR-V in 30%, 60% and 90% strength) and DLIR in low, medium and high strength. CACS was quantified semi-automatically and compared between image reconstructions. In a phantom study, a cardiac calcification insert was scanned inside an anthropomorphic thorax phantom at standard dose, 50% dose and 25% dose. FBP reconstructions at standard dose served as the reference standard. RESULTS In the patient study, DLIR led to a mean underestimation of Agatston score by 3.5, 6.4 and 11.6 points at low, medium and high strength, respectively. This underestimation of Agatston score was less pronounced for DLIR than for ASiR-V. In the phantom study, quantitative CACS results increased with reduced radiation dose and decreased with increasing strength of DLIR. Medium strength DLIR reconstruction at 50% dose reduction and high strength DLIR reconstruction at 75% dose reduction resulted in quantitative CACS results that were comparable to FBP reconstructions at standard dose. CONCLUSION Compared to FBP as the historical reference standard, DLIR leads to an underestimation of CACS but this underestimation is more moderate than with ASiR-V. DLIR can offset the increase in image noise and calcium score at reduced dose and may thus allow for substantial radiation dose reductions in CACS studies.
Collapse
Affiliation(s)
- Ann-Christin Klemenz
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Center Rostock, Schillingallee 36, 18057 Rostock, Germany
| | - Lynn Beckert
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Center Rostock, Schillingallee 36, 18057 Rostock, Germany
| | - Mathias Manzke
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Center Rostock, Schillingallee 36, 18057 Rostock, Germany
| | - Cajetan I Lang
- Department of Cardiology, University Medical Center Rostock, Rostock, Germany
| | - Marc-André Weber
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Center Rostock, Schillingallee 36, 18057 Rostock, Germany
| | - Felix G Meinel
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Center Rostock, Schillingallee 36, 18057 Rostock, Germany.
| |
Collapse
|
8
|
Bos D, Demircioğlu A, Neuhoff J, Haubold J, Zensen S, Opitz MK, Drews MA, Li Y, Styczen H, Forsting M, Nassenstein K. Assessment of image quality and impact of deep learning-based software in non-contrast head CT scans. Sci Rep 2024; 14:11810. [PMID: 38782976 PMCID: PMC11116440 DOI: 10.1038/s41598-024-62394-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Accepted: 05/16/2024] [Indexed: 05/25/2024] Open
Abstract
In this retrospective study, we aimed to assess the objective and subjective image quality of different reconstruction techniques and a deep learning-based software on non-contrast head computed tomography (CT) images. In total, 152 adult head CT scans (77 female, 75 male; mean age 69.4 ± 18.3 years) obtained from three different CT scanners using different protocols between March and April 2021 were included. CT images were reconstructed using filtered-back projection (FBP), iterative reconstruction (IR), and post-processed using a deep learning-based algorithm (PS). Post-processing significantly reduced noise in FBP-reconstructed images (up to 15.4% reduction) depending on the protocol, leading to improvements in signal-to-noise ratio of up to 19.7%. However, when deep learning-based post-processing was applied to FBP images compared to IR alone, the differences were inconsistent and partly non-significant, which appeared to be protocol or site specific. Subjective assessments showed no significant overall improvement in image quality for all reconstructions and post-processing. Inter-rater reliability was low and preferences varied. Deep learning-based denoising software improved objective image quality compared to FBP in routine head CT. A significant difference compared to IR was observed for only one protocol. Subjective assessments did not indicate a significant clinical impact in terms of improved subjective image quality, likely due to the low noise levels in full-dose images.
Collapse
Affiliation(s)
- Denise Bos
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstraße 55, 45147, Essen, Germany.
| | - Aydin Demircioğlu
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Julia Neuhoff
- Faculty of Medicine, University Duisburg-Essen, Hufelandstraße 55, 45122, Essen, Germany
| | - Johannes Haubold
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Sebastian Zensen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Marcel K Opitz
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Marcel A Drews
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Yan Li
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Hanna Styczen
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Michael Forsting
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstraße 55, 45147, Essen, Germany
| | - Kai Nassenstein
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstraße 55, 45147, Essen, Germany
| |
Collapse
|
9
|
Im JY, Halliburton SS, Mei K, Perkins AE, Wong E, Roshkovan L, Sandvold OF, Liu LP, Gang GJ, Noël PB. Patient-derived PixelPrint phantoms for evaluating clinical imaging performance of a deep learning CT reconstruction algorithm. Phys Med Biol 2024; 69:115009. [PMID: 38604190 PMCID: PMC11097966 DOI: 10.1088/1361-6560/ad3dba] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 03/22/2024] [Accepted: 04/11/2024] [Indexed: 04/13/2024]
Abstract
Objective. Deep learning reconstruction (DLR) algorithms exhibit object-dependent resolution and noise performance. Thus, traditional geometric CT phantoms cannot fully capture the clinical imaging performance of DLR. This study uses a patient-derived 3D-printed PixelPrint lung phantom to evaluate a commercial DLR algorithm across a wide range of radiation dose levels.Method. The lung phantom used in this study is based on a patient chest CT scan containing ground glass opacities and was fabricated using PixelPrint 3D-printing technology. The phantom was placed inside two different size extension rings to mimic a small- and medium-sized patient and was scanned on a conventional CT scanner at exposures between 0.5 and 20 mGy. Each scan was reconstructed using filtered back projection (FBP), iterative reconstruction, and DLR at five levels of denoising. Image noise, contrast to noise ratio (CNR), root mean squared error, structural similarity index (SSIM), and multi-scale SSIM (MS SSIM) were calculated for each image.Results.DLR demonstrated superior performance compared to FBP and iterative reconstruction for all measured metrics in both phantom sizes, with better performance for more aggressive denoising levels. DLR was estimated to reduce dose by 25%-83% in the small phantom and by 50%-83% in the medium phantom without decreasing image quality for any of the metrics measured in this study. These dose reduction estimates are more conservative compared to the estimates obtained when only considering noise and CNR.Conclusion. DLR has the capability of producing diagnostic image quality at up to 83% lower radiation dose, which can improve the clinical utility and viability of lower dose CT scans. Furthermore, the PixelPrint phantom used in this study offers an improved testing environment with more realistic tissue structures compared to traditional CT phantoms, allowing for structure-based image quality evaluation beyond noise and contrast-based assessments.
Collapse
Affiliation(s)
- Jessica Y Im
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States of America
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, United States of America
| | | | - Kai Mei
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States of America
| | - Amy E Perkins
- Philips Healthcare, Cleveland, OH, United States of America
| | - Eddy Wong
- Philips Healthcare, Cleveland, OH, United States of America
| | - Leonid Roshkovan
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States of America
| | - Olivia F Sandvold
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States of America
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, United States of America
| | - Leening P Liu
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States of America
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, United States of America
| | - Grace J Gang
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States of America
| | - Peter B Noël
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States of America
| |
Collapse
|
10
|
Salyapongse AM, Kanne JP, Nagpal P, Laucis NC, Markhardt BK, Yin Z, Slavic S, Lubner MG, Szczykutowicz TP. Spatial Resolution Fidelity Comparison Between Energy Integrating and Deep Silicon Photon Counting CT: Implications for Pulmonary Imaging. J Thorac Imaging 2024:00005382-990000000-00137. [PMID: 38712920 DOI: 10.1097/rti.0000000000000788] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/08/2024]
Abstract
PURPOSE We investigated spatial resolution loss away from isocenter for a prototype deep silicon photon-counting detector (PCD) CT scanner and compare with a clinical energy-integrating detector (EID) CT scanner. MATERIALS AND METHODS We performed three scans on a wire phantom at four positions (isocenter, 6.7, 11.8, and 17.1 cm off isocenter). The acquisition modes were 120 kV EID CT, 120 kV high-definition (HD) EID CT, and 120 kV PCD CT. HD mode used double the projection view angles per rotation as the "regular" EID scan mode. The diameter of the wire was calculated by taking the full width of half max (FWHM) of a profile drawn over the radial and azimuthal directions of the wire. Change in wire diameter appearance was assessed by calculating the ratio of the radial and azimuthal diameter relative to isocenter. t tests were used to make pairwise comparisons of the wire diameter ratio with each acquisition and mean ratios' difference from unity. RESULTS Deep silicon PCD CT had statistically smaller (P<0.05) changes in diameter ratio for both radial and azimuthal directions compared with both regular and HD EID modes and was not statistically different from unity (P<0.05). Maximum increases in FWMH relative to isocenter were 36%, 12%, and 1% for regular EID, HD EID, and deep silicon PCD, respectively. CONCLUSION Deep silicon PCD CT exhibits less change in spatial resolution in both the radial and azimuthal directions compared with EID CT.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | - Timothy P Szczykutowicz
- Departments of Radiology, Medical Physics, and Biomedical Engineering, University of Wisconsin Madison, Madison, WI
| |
Collapse
|
11
|
Ries A, Dorosti T, Thalhammer J, Sasse D, Sauter A, Meurer F, Benne A, Lasser T, Pfeiffer F, Schaff F, Pfeiffer D. Improving image quality of sparse-view lung tumor CT images with U-Net. Eur Radiol Exp 2024; 8:54. [PMID: 38698099 PMCID: PMC11065797 DOI: 10.1186/s41747-024-00450-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Accepted: 02/09/2024] [Indexed: 05/05/2024] Open
Abstract
BACKGROUND We aimed to improve the image quality (IQ) of sparse-view computed tomography (CT) images using a U-Net for lung metastasis detection and determine the best tradeoff between number of views, IQ, and diagnostic confidence. METHODS CT images from 41 subjects aged 62.8 ± 10.6 years (mean ± standard deviation, 23 men), 34 with lung metastasis, 7 healthy, were retrospectively selected (2016-2018) and forward projected onto 2,048-view sinograms. Six corresponding sparse-view CT data subsets at varying levels of undersampling were reconstructed from sinograms using filtered backprojection with 16, 32, 64, 128, 256, and 512 views. A dual-frame U-Net was trained and evaluated for each subsampling level on 8,658 images from 22 diseased subjects. A representative image per scan was selected from 19 subjects (12 diseased, 7 healthy) for a single-blinded multireader study. These slices, for all levels of subsampling, with and without U-Net postprocessing, were presented to three readers. IQ and diagnostic confidence were ranked using predefined scales. Subjective nodule segmentation was evaluated using sensitivity and Dice similarity coefficient (DSC); clustered Wilcoxon signed-rank test was used. RESULTS The 64-projection sparse-view images resulted in 0.89 sensitivity and 0.81 DSC, while their counterparts, postprocessed with the U-Net, had improved metrics (0.94 sensitivity and 0.85 DSC) (p = 0.400). Fewer views led to insufficient IQ for diagnosis. For increased views, no substantial discrepancies were noted between sparse-view and postprocessed images. CONCLUSIONS Projection views can be reduced from 2,048 to 64 while maintaining IQ and the confidence of the radiologists on a satisfactory level. RELEVANCE STATEMENT Our reader study demonstrates the benefit of U-Net postprocessing for regular CT screenings of patients with lung metastasis to increase the IQ and diagnostic confidence while reducing the dose. KEY POINTS • Sparse-projection-view streak artifacts reduce the quality and usability of sparse-view CT images. • U-Net-based postprocessing removes sparse-view artifacts while maintaining diagnostically accurate IQ. • Postprocessed sparse-view CTs drastically increase radiologists' confidence in diagnosing lung metastasis.
Collapse
Affiliation(s)
- Annika Ries
- Chair of Biomedical Physics, Department of Physics, School of Natural Sciences, Technical University of Munich, Garching, 85748, Germany
- Munich Institute of Biomedical Engineering, Technical University of Munich, 85748, Garching, Germany
| | - Tina Dorosti
- Chair of Biomedical Physics, Department of Physics, School of Natural Sciences, Technical University of Munich, Garching, 85748, Germany.
- Munich Institute of Biomedical Engineering, Technical University of Munich, 85748, Garching, Germany.
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum Rechts Der Isar, Technical University of Munich, 81675, Munich, Germany.
| | - Johannes Thalhammer
- Chair of Biomedical Physics, Department of Physics, School of Natural Sciences, Technical University of Munich, Garching, 85748, Germany
- Munich Institute of Biomedical Engineering, Technical University of Munich, 85748, Garching, Germany
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum Rechts Der Isar, Technical University of Munich, 81675, Munich, Germany
- Institute for Advanced Study, Technical University of Munich, 85748, Garching, Germany
| | - Daniel Sasse
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum Rechts Der Isar, Technical University of Munich, 81675, Munich, Germany
| | - Andreas Sauter
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum Rechts Der Isar, Technical University of Munich, 81675, Munich, Germany
| | - Felix Meurer
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum Rechts Der Isar, Technical University of Munich, 81675, Munich, Germany
| | - Ashley Benne
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum Rechts Der Isar, Technical University of Munich, 81675, Munich, Germany
- Institute for Advanced Study, Technical University of Munich, 85748, Garching, Germany
| | - Tobias Lasser
- Munich Institute of Biomedical Engineering, Technical University of Munich, 85748, Garching, Germany
- Computational Imaging and Inverse Problems, Department of Computer Science, School of Computation, Information, and Technology, Technical University of Munich, 85748, Garching, Germany
| | - Franz Pfeiffer
- Chair of Biomedical Physics, Department of Physics, School of Natural Sciences, Technical University of Munich, Garching, 85748, Germany
- Munich Institute of Biomedical Engineering, Technical University of Munich, 85748, Garching, Germany
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum Rechts Der Isar, Technical University of Munich, 81675, Munich, Germany
- Institute for Advanced Study, Technical University of Munich, 85748, Garching, Germany
| | - Florian Schaff
- Chair of Biomedical Physics, Department of Physics, School of Natural Sciences, Technical University of Munich, Garching, 85748, Germany
- Munich Institute of Biomedical Engineering, Technical University of Munich, 85748, Garching, Germany
| | - Daniela Pfeiffer
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum Rechts Der Isar, Technical University of Munich, 81675, Munich, Germany
- Institute for Advanced Study, Technical University of Munich, 85748, Garching, Germany
| |
Collapse
|
12
|
Brendlin AS, Dehdab R, Stenzl B, Mueck J, Ghibes P, Groezinger G, Kim J, Afat S, Artzner C. Novel Deep Learning Denoising Enhances Image Quality and Lowers Radiation Exposure in Interventional Bronchial Artery Embolization Cone Beam CT. Acad Radiol 2024; 31:2144-2155. [PMID: 37989681 DOI: 10.1016/j.acra.2023.11.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 10/23/2023] [Accepted: 11/01/2023] [Indexed: 11/23/2023]
Abstract
OBJECTIVES In interventional bronchial artery embolization (BAE), periprocedural cone beam CT (CBCT) improves guiding and localization. However, a trade-off exists between 6-second runs (high radiation dose and motion artifacts, but low noise) and 3-second runs (vice versa). This study aimed to determine the efficacy of an advanced deep learning denoising (DLD) technique in mitigating the trade-offs related to radiation dose and image quality during interventional BAE CBCT. MATERIALS AND METHODS This study included BMI-matched patients undergoing 6-second and 3-second BAE CBCT scans. The dose-area product values (DAP) were obtained. All datasets were reconstructed using standard weighted filtered back projection (OR) and a novel DLD software. Objective image metrics were derived from place-consistent regions of interest, including CT numbers of the Aorta and lung, noise, and contrast-to-noise ratio. Three blinded radiologists performed subjective assessments regarding image quality, sharpness, contrast, and motion artifacts on all dataset combinations in a forced-choice setup (-1 = inferior, 0 = equal; 1 = superior). The points were averaged per item for a total score. Statistical analysis ensued using a properly corrected mixed-effects model with post hoc pairwise comparisons. RESULTS Sixty patients were assessed in 30 matched pairs (age 64 ± 15 years; 10 female). The mean DAP for the 6 s and 3 s runs was 2199 ± 185 µGym² and 1227 ± 90 µGym², respectively. Neither low-dose imaging nor the reconstruction method introduced a significant HU shift (p ≥ 0.127). The 3 s-DLD presented the least noise and superior contrast-to-noise ratio (CNR) (p < 0.001). While subjective evaluation revealed no noticeable distinction between 6 s-DLD and 3 s-DLD in terms of quality (p ≥ 0.996), both outperformed the OR variants (p < 0.001). The 3 s datasets exhibited fewer motion artifacts than the 6 s datasets (p < 0.001). CONCLUSIONS DLD effectively mitigates the trade-off between radiation dose, image noise, and motion artifact burden in regular reconstructed BAE CBCT by enabling diagnostic scans with low radiation exposure and inherently low motion artifact burden at short examination times.
Collapse
Affiliation(s)
- Andreas S Brendlin
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls University, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany (A.S.B., R.D., B.S., J.M., P.G., G.G., S.A., C.A.).
| | - Reza Dehdab
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls University, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany (A.S.B., R.D., B.S., J.M., P.G., G.G., S.A., C.A.)
| | - Benedikt Stenzl
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls University, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany (A.S.B., R.D., B.S., J.M., P.G., G.G., S.A., C.A.)
| | - Jonas Mueck
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls University, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany (A.S.B., R.D., B.S., J.M., P.G., G.G., S.A., C.A.)
| | - Patrick Ghibes
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls University, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany (A.S.B., R.D., B.S., J.M., P.G., G.G., S.A., C.A.)
| | - Gerd Groezinger
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls University, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany (A.S.B., R.D., B.S., J.M., P.G., G.G., S.A., C.A.)
| | - Jonghyo Kim
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul 03080, Republic of Korea (J.K.); ClariPi Inc., 11 Ihwajang 1-gil, Jongno-gu, Seoul 03088, Republic of Korea (J.K.)
| | - Saif Afat
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls University, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany (A.S.B., R.D., B.S., J.M., P.G., G.G., S.A., C.A.)
| | - Christoph Artzner
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls University, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany (A.S.B., R.D., B.S., J.M., P.G., G.G., S.A., C.A.)
| |
Collapse
|
13
|
Rep S, Jensterle L, Zdešar U, Zaletel K, Tomše P, Ležaič L. Contribution of CT scan to patient's radiation exposure in parathyroid SPECT/CT scintigraphy. Radiography (Lond) 2024; 30:995-1000. [PMID: 38688163 DOI: 10.1016/j.radi.2024.04.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Revised: 04/11/2024] [Accepted: 04/11/2024] [Indexed: 05/02/2024]
Abstract
INTRODUCTION Dual phase technetium-99mTc-methoxy isobutyl isonitrile (MIBI) single-photon emission computed tomography with computed tomography (SPECT/CT) may be the most accurate conventional imaging approach for localization of enlarged parathyroid gland (EPG). The imaging is based on the radiopharmaceutical (RP) retention in EPG compared to washout from normal thyroid and normal parathyroid glands. This study aimed to estimate and optimize the contribution of computed tomography (CT) scan and scan range to effective dose (ED) in dual-phase MIBI SPECT/CT parathyroid scintigraphy. METHODS The study included seventy-four patients; thirty-seven with reduced and thirty-seven with extended CT scan range. The ED caused by the CT scan was calculated using Dose Length Product (DLP) data and estimated using the Imaging Performance Assessment of CT scanners (ImPACT) calculator. RESULTS For all patients, the contribution of CT to the ED in a combined SPECT/CT examination was 2.62 ± 0.29 mSv (48%). The contribution of CT to the total ED was 1.8 ± 0.18 mSv (33%) when using reduced and 3.44 ± 0.23 mSv (64%) when using extended scan range. The DLP and ED were statistically significantly different between the reduced and extended CT scan range (p < 0.001) in the first and second phases. The individual organ dose was reduced from 8% to 94%. CONCLUSION The hybrid SPECT/CT improves the interpretation of nuclear medicine images and also increases the radiation dose to the patient. An adequately defined CT scan range on SPECT/CT imaging, can significantly reduce a patient's ED. IMPLICATIONS FOR PRACTICE The research findings showed that knowledge of anatomy, pathology and technology can provide optimising diagnostic procedures and reduce patient ED after SPECT/CT scans.
Collapse
Affiliation(s)
- S Rep
- Department of Nuclear Medicine, University Medical Centre Ljubljana, Slovenia; University of Ljubljana, Faculty of Health Sciences, Slovenia.
| | - L Jensterle
- Department of Nuclear Medicine, University Medical Centre Ljubljana, Slovenia
| | - U Zdešar
- Institute of Occupational Safety, Ljubljana, Slovenia
| | - K Zaletel
- Department of Nuclear Medicine, University Medical Centre Ljubljana, Slovenia; Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| | - P Tomše
- Department of Nuclear Medicine, University Medical Centre Ljubljana, Slovenia
| | - L Ležaič
- Department of Nuclear Medicine, University Medical Centre Ljubljana, Slovenia; Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| |
Collapse
|
14
|
Gennari AG, Rossi A, De Cecco CN, van Assen M, Sartoretti T, Giannopoulos AA, Schwyzer M, Huellner MW, Messerli M. Artificial intelligence in coronary artery calcium score: rationale, different approaches, and outcomes. Int J Cardiovasc Imaging 2024; 40:951-966. [PMID: 38700819 PMCID: PMC11147943 DOI: 10.1007/s10554-024-03080-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2024] [Accepted: 03/09/2024] [Indexed: 06/05/2024]
Abstract
Almost 35 years after its introduction, coronary artery calcium score (CACS) not only survived technological advances but became one of the cornerstones of contemporary cardiovascular imaging. Its simplicity and quantitative nature established it as one of the most robust approaches for atherosclerotic cardiovascular disease risk stratification in primary prevention and a powerful tool to guide therapeutic choices. Groundbreaking advances in computational models and computer power translated into a surge of artificial intelligence (AI)-based approaches directly or indirectly linked to CACS analysis. This review aims to provide essential knowledge on the AI-based techniques currently applied to CACS, setting the stage for a holistic analysis of the use of these techniques in coronary artery calcium imaging. While the focus of the review will be detailing the evidence, strengths, and limitations of end-to-end CACS algorithms in electrocardiography-gated and non-gated scans, the current role of deep-learning image reconstructions, segmentation techniques, and combined applications such as simultaneous coronary artery calcium and pulmonary nodule segmentation, will also be discussed.
Collapse
Affiliation(s)
- Antonio G Gennari
- Department of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, Zurich, 8091, Switzerland
- University of Zurich, Zurich, Switzerland
| | - Alexia Rossi
- Department of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, Zurich, 8091, Switzerland
- University of Zurich, Zurich, Switzerland
| | - Carlo N De Cecco
- Division of Cardiothoracic Imaging, Department of Radiology and Imaging Sciences, Emory University, Atlanta, GA, USA
- Translational Laboratory for Cardiothoracic Imaging and Artificial Intelligence, Emory University, Atlanta, GA, USA
| | - Marly van Assen
- Translational Laboratory for Cardiothoracic Imaging and Artificial Intelligence, Emory University, Atlanta, GA, USA
| | - Thomas Sartoretti
- Department of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, Zurich, 8091, Switzerland
- University of Zurich, Zurich, Switzerland
| | - Andreas A Giannopoulos
- Department of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, Zurich, 8091, Switzerland
| | - Moritz Schwyzer
- Department of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, Zurich, 8091, Switzerland
- University of Zurich, Zurich, Switzerland
| | - Martin W Huellner
- Department of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, Zurich, 8091, Switzerland
- University of Zurich, Zurich, Switzerland
| | - Michael Messerli
- Department of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, Zurich, 8091, Switzerland.
- University of Zurich, Zurich, Switzerland.
| |
Collapse
|
15
|
Chandran M O, Pendem S, P S P, Chacko C, - P, Kadavigere R. Influence of deep learning image reconstruction algorithm for reducing radiation dose and image noise compared to iterative reconstruction and filtered back projection for head and chest computed tomography examinations: a systematic review. F1000Res 2024; 13:274. [PMID: 38725640 PMCID: PMC11079581 DOI: 10.12688/f1000research.147345.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 03/26/2024] [Indexed: 05/12/2024] Open
Abstract
Background The most recent advances in Computed Tomography (CT) image reconstruction technology are Deep learning image reconstruction (DLIR) algorithms. Due to drawbacks in Iterative reconstruction (IR) techniques such as negative image texture and nonlinear spatial resolutions, DLIRs are gradually replacing them. However, the potential use of DLIR in Head and Chest CT has to be examined further. Hence, the purpose of the study is to review the influence of DLIR on Radiation dose (RD), Image noise (IN), and outcomes of the studies compared with IR and FBP in Head and Chest CT examinations. Methods We performed a detailed search in PubMed, Scopus, Web of Science, Cochrane Library, and Embase to find the articles reported using DLIR for Head and Chest CT examinations between 2017 to 2023. Data were retrieved from the short-listed studies using Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guidelines. Results Out of 196 articles searched, 15 articles were included. A total of 1292 sample size was included. 14 articles were rated as high and 1 article as moderate quality. All studies compared DLIR to IR techniques. 5 studies compared DLIR with IR and FBP. The review showed that DLIR improved IQ, and reduced RD and IN for CT Head and Chest examinations. Conclusions DLIR algorithm have demonstrated a noted enhancement in IQ with reduced IN for CT Head and Chest examinations at lower dose compared with IR and FBP. DLIR showed potential for enhancing patient care by reducing radiation risks and increasing diagnostic accuracy.
Collapse
Affiliation(s)
- Obhuli Chandran M
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Saikiran Pendem
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Priya P S
- Department of Radio Diagnosis and Imaging, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Cijo Chacko
- Philips Research and Development, Philips Innovation Campus, Yelahanka, Karnataka, 560064, India
| | - Priyanka -
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Rajagopal Kadavigere
- Department of Radio Diagnosis and Imaging, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| |
Collapse
|
16
|
Schindler P, Gerwing M. Using deep learning-based denoising and iterative reconstruction to reduce radiation exposure - How low can we go? Eur J Radiol 2024; 173:111376. [PMID: 38377893 DOI: 10.1016/j.ejrad.2024.111376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Accepted: 02/15/2024] [Indexed: 02/22/2024]
Affiliation(s)
- Philipp Schindler
- Clinic for Radiology, University and University Hospital of Münster, Münster, Germany
| | - Mirjam Gerwing
- Clinic for Radiology, University and University Hospital of Münster, Münster, Germany.
| |
Collapse
|
17
|
Zhou Z, Gong H, Hsieh S, McCollough CH, Yu L. Image quality evaluation in deep-learning-based CT noise reduction using virtual imaging trial methods: Contrast-dependent spatial resolution. Med Phys 2024. [PMID: 38555876 DOI: 10.1002/mp.17029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Revised: 02/19/2024] [Accepted: 02/26/2024] [Indexed: 04/02/2024] Open
Abstract
BACKGROUND Deep-learning-based image reconstruction and noise reduction methods (DLIR) have been increasingly deployed in clinical CT. Accurate image quality assessment of these methods is challenging as the performance measured using physical phantoms may not represent the true performance of DLIR in patients since DLIR is trained mostly on patient images. PURPOSE In this work, we aim to develop a patient-data-based virtual imaging trial framework and, as a first application, use it to measure the spatial resolution properties of a DLIR method. METHODS The patient-data-based virtual imaging trial framework consists of five steps: (1) insertion of lesions into projection domain data using the acquisition geometry of the patient exam to simulate different lesion characteristics; (2) insertion of noise into projection domain data using a realistic photon statistical model of the CT system to simulate different dose levels; (3) creation of DLIR-processed images from projection or image data; (4) creation of ensembles of DLIR-processed patient images from a large number of noise and lesion realizations; and (5) evaluation of image quality using ensemble DLIR images. This framework was applied to measure the spatial resolution of a ResNet based deep convolutional neural network (DCNN) trained on patient images. Lesions in a cylindrical shape and different contrast levels (-500, -100, -50, -20, -10 HU) were inserted to the lower right lobe of the liver in a patient case. Multiple dose levels were simulated (50%, 25%, 12.5%). Each lesion and dose condition had 600 noise realizations. Multiple reconstruction and denoising methods were used on all the noise realizations, including the original filtered-backprojection (FBP), iterative reconstruction (IR), and the DCNN method with three different strength setting (DCNN-weak, DCNN-medium, and DCNN-strong). Mean lesion signal was calculated by performing ensemble averaging of all the noise realizations for each lesion and dose condition and then subtracting the lesion-present images from the lesion absent images. Modulation transfer functions (MTFs) both in-plane and along the z-axis were calculated based on the mean lesion signals. The standard deviations of MTFs at each condition were estimated with bootstrapping: randomly sampling (with replacement) all the DLIR/FBP/IR images from the ensemble data (600 samples) at each condition. The impact of varying lesion contrast, dose levels, and denoising strengths were evaluated. Statistical analysis with paired t-test was used to compare the z-axis and in-plane spatial resolution of five algorithms for five different contrasts and three dose levels. RESULTS The in-plane and z-axis spatial resolution degradation of DCNN becomes more severe as the contrast or radiation dose decreased, or DCNN denoising strength increased. In comparison with FBP, a 59.5% and 4.1% reduction of in-plane and z-axis MTF (in terms of spatial frequencies at 50% MTF), respectively, was observed at low contrast (-10 HU) for DCNN with the highest denoising strength at 25% routine dose level. When the dose level reduces from 50% to 12.5% of routine dose, the in-plane and z-axis MTFs reduces from 92.1% to 76.3%, and from 98.9% to 95.5%, respectively, at contrast of -100 HU, using FBP as the reference. For most conditions of contrasts and dose levels, significant differences were found among the five algorithms, with the following relationship in both in-plane and cross-plane spatial resolution: FBP > DCNN-Weak > IR > DCNN-Medium > DCNN-Strong. The spatial resolution difference among algorithms decreases at higher contrast or dose levels. CONCLUSIONS A patient-data-based virtual imaging trial framework was developed and applied to measuring the spatial resolution properties of a DCNN noise reduction method at different contrast and dose levels using real patient data. As with other non-linear image reconstruction and post-processing techniques, the evaluated DCNN method degraded the in-plane and z-axis spatial resolution at lower contrast levels, lower radiation dose, and higher denoising strength.
Collapse
Affiliation(s)
- Zhongxing Zhou
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | - Hao Gong
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | - Scott Hsieh
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | | | - Lifeng Yu
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| |
Collapse
|
18
|
You Y, Zhong S, Zhang G, Wen Y, Guo D, Li W, Li Z. Exploring the Low-Dose Limit for Focal Hepatic Lesion Detection with a Deep Learning-Based CT Reconstruction Algorithm: A Simulation Study on Patient Images. JOURNAL OF IMAGING INFORMATICS IN MEDICINE 2024:10.1007/s10278-024-01080-3. [PMID: 38502435 DOI: 10.1007/s10278-024-01080-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Revised: 03/06/2024] [Accepted: 03/07/2024] [Indexed: 03/21/2024]
Abstract
This study aims to investigate the maximum achievable dose reduction for applying a new deep learning-based reconstruction algorithm, namely the artificial intelligence iterative reconstruction (AIIR), in computed tomography (CT) for hepatic lesion detection. A total of 40 patients with 98 clinically confirmed hepatic lesions were retrospectively included. The mean volume CT dose index was 13.66 ± 1.73 mGy in routine-dose portal venous CT examinations, where the images were originally obtained with hybrid iterative reconstruction (HIR). Low-dose simulations were performed in projection domain for 40%-, 20%-, and 10%-dose levels, followed by reconstruction using both HIR and AIIR. Two radiologists were asked to detect hepatic lesion on each set of low-dose image in separate sessions. Qualitative metrics including lesion conspicuity, diagnostic confidence, and overall image quality were evaluated using a 5-point scale. The contrast-to-noise ratio (CNR) for lesion was also calculated for quantitative assessment. The lesion CNR on AIIR at reduced doses were significantly higher than that on routine-dose HIR (all p < 0.05). Lower qualitative image quality was observed as the radiation dose reduced, while there were no significant differences between 40%-dose AIIR and routine-dose HIR images. The lesion detection rate was 100%, 98% (96/98), and 73.5% (72/98) on 40%-, 20%-, and 10%-dose AIIR, respectively, whereas it was 98% (96/98), 73.5% (72/98), and 40% (39/98) on the corresponding low-dose HIR, respectively. AIIR outperformed HIR in simulated low-dose CT examinations of the liver. The use of AIIR allows up to 60% dose reduction for lesion detection while maintaining comparable image quality to routine-dose HIR.
Collapse
Affiliation(s)
- Yongchun You
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | | | | | - Yuting Wen
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | - Dian Guo
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | - Wanjiang Li
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China.
| | - Zhenlin Li
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China.
| |
Collapse
|
19
|
Kazimierczak W, Kędziora K, Janiszewska-Olszowska J, Kazimierczak N, Serafin Z. Noise-Optimized CBCT Imaging of Temporomandibular Joints-The Impact of AI on Image Quality. J Clin Med 2024; 13:1502. [PMID: 38592413 PMCID: PMC10932444 DOI: 10.3390/jcm13051502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Revised: 02/28/2024] [Accepted: 03/04/2024] [Indexed: 04/10/2024] Open
Abstract
Background: Temporomandibular joint disorder (TMD) is a common medical condition. Cone beam computed tomography (CBCT) is effective in assessing TMD-related bone changes, but image noise may impair diagnosis. Emerging deep learning reconstruction algorithms (DLRs) could minimize noise and improve CBCT image clarity. This study compares standard and deep learning-enhanced CBCT images for image quality in detecting osteoarthritis-related degeneration in TMJs (temporomandibular joints). This study analyzed CBCT images of patients with suspected temporomandibular joint degenerative joint disease (TMJ DJD). Methods: The DLM reconstructions were performed with ClariCT.AI software. Image quality was evaluated objectively via CNR in target areas and subjectively by two experts using a five-point scale. Both readers also assessed TMJ DJD lesions. The study involved 50 patients with a mean age of 28.29 years. Results: Objective analysis revealed a significantly better image quality in DLM reconstructions (CNR levels; p < 0.001). Subjective assessment showed high inter-reader agreement (κ = 0.805) but no significant difference in image quality between the reconstruction types (p = 0.055). Lesion counts were not significantly correlated with the reconstruction type (p > 0.05). Conclusions: The analyzed DLM reconstruction notably enhanced the objective image quality in TMJ CBCT images but did not significantly alter the subjective quality or DJD lesion diagnosis. However, the readers favored DLM images, indicating the potential for better TMD diagnosis with CBCT, meriting more study.
Collapse
Affiliation(s)
- Wojciech Kazimierczak
- Department of Radiology and Diagnostic Imaging, Collegium Medicum, Nicolaus Copernicus University in Torun, Jagiellońska 13-15, 85-067 Bydgoszcz, Poland
- Department of Interdisciplinary Dentistry, Pomeranian Medical University in Szczecin, 70-111 Szczecin, Poland
| | - Kamila Kędziora
- Department of Radiology and Diagnostic Imaging, Collegium Medicum, Nicolaus Copernicus University in Torun, Jagiellońska 13-15, 85-067 Bydgoszcz, Poland
| | | | - Natalia Kazimierczak
- Kazimierczak Private Medical Practice, Dworcowa 13/u6a, 85-009 Bydgoszcz, Poland
| | - Zbigniew Serafin
- Department of Radiology and Diagnostic Imaging, Collegium Medicum, Nicolaus Copernicus University in Torun, Jagiellońska 13-15, 85-067 Bydgoszcz, Poland
| |
Collapse
|
20
|
Chen H, Li Q, Zhou L, Li F. Deep learning-based algorithms for low-dose CT imaging: A review. Eur J Radiol 2024; 172:111355. [PMID: 38325188 DOI: 10.1016/j.ejrad.2024.111355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 01/05/2024] [Accepted: 01/31/2024] [Indexed: 02/09/2024]
Abstract
The computed tomography (CT) technique is extensively employed as an imaging modality in clinical settings. The radiation dose of CT, however, is significantly high, thereby raising concerns regarding the potential radiation damage it may cause. The reduction of X-ray exposure dose in CT scanning may result in a significant decline in imaging quality, thereby elevating the risk of missed diagnosis and misdiagnosis. The reduction of CT radiation dose and acquisition of high-quality images to meet clinical diagnostic requirements have always been a critical research focus and challenge in the field of CT. Over the years, scholars have conducted extensive research on enhancing low-dose CT (LDCT) imaging algorithms, among which deep learning-based algorithms have demonstrated superior performance. In this review, we initially introduced the conventional algorithms for CT image reconstruction along with their respective advantages and disadvantages. Subsequently, we provided a detailed description of four aspects concerning the application of deep neural networks in LDCT imaging process: preprocessing in the projection domain, post-processing in the image domain, dual-domain processing imaging, and direct deep learning-based reconstruction (DLR). Furthermore, an analysis was conducted to evaluate the merits and demerits of each method. The commercial and clinical applications of the LDCT-DLR algorithm were also presented in an overview. Finally, we summarized the existing issues pertaining to LDCT-DLR and concluded the paper while outlining prospective trends for algorithmic advancement.
Collapse
Affiliation(s)
- Hongchi Chen
- School of Medical Information Engineering, Gannan Medical University, Ganzhou 341000, China
| | - Qiuxia Li
- School of Medical Information Engineering, Gannan Medical University, Ganzhou 341000, China
| | - Lazhen Zhou
- School of Medical Information Engineering, Gannan Medical University, Ganzhou 341000, China
| | - Fangzuo Li
- School of Medical Information Engineering, Gannan Medical University, Ganzhou 341000, China; Key Laboratory of Prevention and Treatment of Cardiovascular and Cerebrovascular Diseases, Ministry of Education, Gannan Medical University, Ganzhou 341000, China.
| |
Collapse
|
21
|
Barat M, Pellat A, Hoeffel C, Dohan A, Coriat R, Fishman EK, Nougaret S, Chu L, Soyer P. CT and MRI of abdominal cancers: current trends and perspectives in the era of radiomics and artificial intelligence. Jpn J Radiol 2024; 42:246-260. [PMID: 37926780 DOI: 10.1007/s11604-023-01504-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Accepted: 10/12/2023] [Indexed: 11/07/2023]
Abstract
Abdominal cancers continue to pose daily challenges to clinicians, radiologists and researchers. These challenges are faced at each stage of abdominal cancer management, including early detection, accurate characterization, precise assessment of tumor spread, preoperative planning when surgery is anticipated, prediction of tumor aggressiveness, response to therapy, and detection of recurrence. Technical advances in medical imaging, often in combination with imaging biomarkers, show great promise in addressing such challenges. Information extracted from imaging datasets owing to the application of radiomics can be used to further improve the diagnostic capabilities of imaging. However, the analysis of the huge amount of data provided by these advances is a difficult task in daily practice. Artificial intelligence has the potential to help radiologists in all these challenges. Notably, the applications of AI in the field of abdominal cancers are expanding and now include diverse approaches for cancer detection, diagnosis and classification, genomics and detection of genetic alterations, analysis of tumor microenvironment, identification of predictive biomarkers and follow-up. However, AI currently has some limitations that need further refinement for implementation in the clinical setting. This review article sums up recent advances in imaging of abdominal cancers in the field of image/data acquisition, tumor detection, tumor characterization, prognosis, and treatment response evaluation.
Collapse
Affiliation(s)
- Maxime Barat
- Department of Radiology, Hôpital Cochin, Assistance Publique-Hopitaux de Paris, 75014, Paris, France
- Faculté de Médecine, Université Paris Cité, 75006, Paris, France
| | - Anna Pellat
- Faculté de Médecine, Université Paris Cité, 75006, Paris, France
- Department of Gastroenterology and Digestive Oncology, Hôpital Cochin, Assistance Publique-Hopitaux de Paris, 75014, Paris, France
| | - Christine Hoeffel
- Department of Radiology, Hopital Robert Debré, CHU Reims, Université Champagne-Ardennes, 51092, Reims, France
| | - Anthony Dohan
- Department of Radiology, Hôpital Cochin, Assistance Publique-Hopitaux de Paris, 75014, Paris, France
- Faculté de Médecine, Université Paris Cité, 75006, Paris, France
| | - Romain Coriat
- Faculté de Médecine, Université Paris Cité, 75006, Paris, France
- Department of Gastroenterology and Digestive Oncology, Hôpital Cochin, Assistance Publique-Hopitaux de Paris, 75014, Paris, France
| | - Elliot K Fishman
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, 21287, USA
| | - Stéphanie Nougaret
- Department of Radiology, Montpellier Cancer Institute, 34000, Montpellier, France
- PINKCC Lab, IRCM, U1194, 34000, Montpellier, France
| | - Linda Chu
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, 21287, USA
| | - Philippe Soyer
- Department of Radiology, Hôpital Cochin, Assistance Publique-Hopitaux de Paris, 75014, Paris, France.
- Faculté de Médecine, Université Paris Cité, 75006, Paris, France.
| |
Collapse
|
22
|
Tomasi S, Szilagyi KE, Barca P, Bisello F, Spagnoli L, Domenichelli S, Strigari L. A CT deep learning reconstruction algorithm: Image quality evaluation for brain protocol at decreasing dose indexes in comparison with FBP and statistical iterative reconstruction algorithms. Phys Med 2024; 119:103319. [PMID: 38422902 DOI: 10.1016/j.ejmp.2024.103319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2023] [Revised: 01/17/2024] [Accepted: 02/09/2024] [Indexed: 03/02/2024] Open
Abstract
PURPOSE To characterise the impact of Precise Image (PI) deep learning reconstruction algorithm on image quality, compared to filtered back-projection (FBP) and iDose4 iterative reconstruction for brain computed tomography (CT) phantom images. METHODS Catphan-600 phantom was acquired with an Incisive CT scanner using a dedicated brain protocol, at six different dose levels (volume computed tomography dose index (CTDIvol): 7/14/29/49/56/67 mGy). Images were reconstructed using FBP, levels 2/5 of iDose4, and PI algorithm (Sharper/Sharp/Standard/Smooth/Smoother). Image quality was assessed by evaluating CT numbers, image histograms, noise, image non-uniformity (NU), noise power spectrum, target transfer function, and detectability index. RESULTS The five PI levels did not significantly affect the mean CT number. For a given CTDIvol using Sharper-to-Smoother levels, the spatial resolution for all the investigated materials and the detectability index increased while the noise magnitude decreased, slightly affecting noise texture. For a fixed PI level increasing the CTDIvol the detectability index increased, the noise magnitude decreased. From 29 mGy, NU values converged within 1 Hounsfield Unit from each other without a substantial improvement at higher CTDIvol values. CONCLUSIONS The improved performances of intermediate PI levels in brain protocols compared to conventional algorithms seem to suggest a potential reduction of CTDIvol.
Collapse
Affiliation(s)
- Silvia Tomasi
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Klarisa Elena Szilagyi
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Patrizio Barca
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy; Unit of Medical Physics, Azienda Ospedaliero-Universitaria Pisana, 56126 Pisa, Italy
| | - Francesca Bisello
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Lorenzo Spagnoli
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Sara Domenichelli
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Lidia Strigari
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy.
| |
Collapse
|
23
|
Nigam S, Gjelaj E, Wang R, Wei GW, Wang P. Machine Learning and Deep Learning Applications in Magnetic Particle Imaging. J Magn Reson Imaging 2024. [PMID: 38358090 DOI: 10.1002/jmri.29294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 01/29/2024] [Accepted: 01/31/2024] [Indexed: 02/16/2024] Open
Abstract
In recent years, magnetic particle imaging (MPI) has emerged as a promising imaging technique depicting high sensitivity and spatial resolution. It originated in the early 2000s where it proposed a new approach to challenge the low spatial resolution achieved by using relaxometry in order to measure the magnetic fields. MPI presents 2D and 3D images with high temporal resolution, non-ionizing radiation, and optimal visual contrast due to its lack of background tissue signal. Traditionally, the images were reconstructed by the conversion of signal from the induced voltage by generating system matrix and X-space based methods. Because image reconstruction and analyses play an integral role in obtaining precise information from MPI signals, newer artificial intelligence-based methods are continuously being researched and developed upon. In this work, we summarize and review the significance and employment of machine learning and deep learning models for applications with MPI and the potential they hold for the future. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Saumya Nigam
- Precision Health Program, Michigan State University, East Lansing, Michigan, USA
- Department of Radiology, College of Human Medicine, Michigan State University, East Lansing, Michigan, USA
| | - Elvira Gjelaj
- Precision Health Program, Michigan State University, East Lansing, Michigan, USA
- Lyman Briggs College, Michigan State University, East Lansing, Michigan, USA
| | - Rui Wang
- Department of Mathematics, College of Natural Science, Michigan State University, East Lansing, Michigan, USA
| | - Guo-Wei Wei
- Department of Mathematics, College of Natural Science, Michigan State University, East Lansing, Michigan, USA
- Department of Electrical and Computer Engineering, College of Engineering, Michigan State University, East Lansing, Michigan, USA
- Department of Biochemistry and Molecular Biology, College of Natural Science, Michigan State University, East Lansing, Michigan, USA
| | - Ping Wang
- Precision Health Program, Michigan State University, East Lansing, Michigan, USA
- Department of Radiology, College of Human Medicine, Michigan State University, East Lansing, Michigan, USA
| |
Collapse
|
24
|
Kazimierczak W, Kazimierczak N, Wilamowska J, Wojtowicz O, Nowak E, Serafin Z. Enhanced visualization in endoleak detection through iterative and AI-noise optimized spectral reconstructions. Sci Rep 2024; 14:3845. [PMID: 38360941 PMCID: PMC10869818 DOI: 10.1038/s41598-024-54502-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Accepted: 02/13/2024] [Indexed: 02/17/2024] Open
Abstract
To assess the image quality parameters of dual-energy computed tomography angiography (DECTA) 40-, and 60 keV virtual monoenergetic images (VMIs) combined with deep learning-based image reconstruction model (DLM) and iterative reconstructions (IR). CT scans of 28 post EVAR patients were enrolled. The 60 s delayed phase of DECTA was evaluated. Objective [noise, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR)] and subjective (overall image quality and endoleak conspicuity - 3 blinded readers assessment) image quality analyses were performed. The following reconstructions were evaluated: VMI 40, 60 keV VMI; IR VMI 40, 60 keV; DLM VMI 40, 60 keV. The noise level of the DLM VMI images was approximately 50% lower than that of VMI reconstruction. The highest CNR and SNR values were measured in VMI DLM images. The mean CNR in endoleak in 40 keV was accounted for as 1.83 ± 1.2; 2.07 ± 2.02; 3.6 ± 3.26 in VMI, VMI IR, and VMI DLM, respectively. The DLM algorithm significantly reduced noise and increased lesion conspicuity, resulting in higher objective and subjective image quality compared to other reconstruction techniques. The application of DLM algorithms to low-energy VMIs significantly enhances the diagnostic value of DECTA in evaluating endoleaks. DLM reconstructions surpass traditional VMIs and IR in terms of image quality.
Collapse
Affiliation(s)
- Wojciech Kazimierczak
- Collegium Medicum, Nicolaus Copernicus University in Torun, Jagiellońska 13-15, 85-067, Bydgoszcz, Poland.
- Kazimierczak Private Medical Practice, Dworcowa 13/u6a, 85-009, Bydgoszcz, Poland.
- University Hospital No 1 in Bydgoszcz, Marii Skłodowskiej - Curie 9, 85-094, Bydgoszcz, Poland.
| | - Natalia Kazimierczak
- Kazimierczak Private Medical Practice, Dworcowa 13/u6a, 85-009, Bydgoszcz, Poland
| | - Justyna Wilamowska
- Collegium Medicum, Nicolaus Copernicus University in Torun, Jagiellońska 13-15, 85-067, Bydgoszcz, Poland
- University Hospital No 1 in Bydgoszcz, Marii Skłodowskiej - Curie 9, 85-094, Bydgoszcz, Poland
| | - Olaf Wojtowicz
- Collegium Medicum, Nicolaus Copernicus University in Torun, Jagiellońska 13-15, 85-067, Bydgoszcz, Poland
- University Hospital No 1 in Bydgoszcz, Marii Skłodowskiej - Curie 9, 85-094, Bydgoszcz, Poland
| | - Ewa Nowak
- University Hospital No 1 in Bydgoszcz, Marii Skłodowskiej - Curie 9, 85-094, Bydgoszcz, Poland
| | - Zbigniew Serafin
- Collegium Medicum, Nicolaus Copernicus University in Torun, Jagiellońska 13-15, 85-067, Bydgoszcz, Poland
- University Hospital No 1 in Bydgoszcz, Marii Skłodowskiej - Curie 9, 85-094, Bydgoszcz, Poland
| |
Collapse
|
25
|
Sharma S, Pal D, Abadi E, Segars P, Hsieh J, Samei E. Deep silicon photon-counting CT: A first simulation-based study for assessing perceptual benefits across diverse anatomies. Eur J Radiol 2024; 171:111279. [PMID: 38194843 PMCID: PMC10922475 DOI: 10.1016/j.ejrad.2023.111279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 11/26/2023] [Accepted: 12/20/2023] [Indexed: 01/11/2024]
Abstract
OBJECTIVES To assess perceptual benefits provided by the improved spatial resolution and noise performance of deep silicon photon-counting CT (Si-PCCT) over conventional energy-integrating CT (ECT) using polychromatic images for various clinical tasks and anatomical regions. MATERIALS AND METHODS Anthropomorphic, computational models were developed for lungs, liver, inner ear, and head-and-neck (H&N) anatomies. These regions included specific abnormalities such as lesions in the lungs and liver, and calcified plaques in the carotid arteries. The anatomical models were imaged using a scanner-specific CT simulation platform (DukeSim) modeling a Si-PCCT prototype and a conventional ECT system at matched dose levels. The simulated polychromatic projections were reconstructed with matched in-plane resolutions using manufacturer-specific software. The reconstructed pairs of images were scored by radiologists to gauge the task-specific perceptual benefits provided by Si-PCCT compared to ECT based on visualization of anatomical and image quality features. The scores were standardized as z-scores for minimizing inter-observer variability and compared between the systems for evidence of statistically significant improvement (one-sided Wilcoxon rank-sum test with a significance level of 0.05) in perceptual performance for Si-PCCT. RESULTS Si-PCCT offered favorable image quality and improved visualization capabilities, leading to mean improvements in task-specific perceptual performance over ECT for most tasks. The improvements for Si-PCCT were statistically significant for the visualization of lung lesion (0.08 ± 0.89 vs. 0.90 ± 0.48), liver lesion (-0.64 ± 0.37 vs. 0.95 ± 0.55), and soft tissue structures (-0.47 ± 0.90 vs. 0.33 ± 1.24) and cochlea (-0.47 ± 0.80 vs. 0.38 ± 0.62) in inner ear. CONCLUSIONS Si-PCCT exhibited mean improvements in task-specific perceptual performance over ECT for most clinical tasks considered in this study, with statistically significant improvement for 6/20 tasks. The perceptual performance of Si-PCCT is expected to improve further with availability of spectral information and reconstruction kernels optimized for high resolution provided by smaller pixel size of Si-PCCT. The outcomes of this study indicate the positive potential of Si-PCCT for benefiting routine clinical practice through improved image quality and visualization capabilities.
Collapse
Affiliation(s)
- Shobhit Sharma
- Center for Virtual Imaging Trials and Carl E. Ravin Advanced Imaging Laboratories, 2424 Erwin Rd, Suite 302, Durham, NC 27705, USA; Department of Physics, Duke University, Science Drive, Durham, NC 27708, USA
| | - Debashish Pal
- GE Healthcare, 3000 N Grandview Blvd, Waukesha, WI 53188, USA
| | - Ehsan Abadi
- Center for Virtual Imaging Trials and Carl E. Ravin Advanced Imaging Laboratories, 2424 Erwin Rd, Suite 302, Durham, NC 27705, USA; Department of Radiology, Duke University, 2301 Erwin Rd, Durham, NC 27705, USA.
| | - Paul Segars
- Center for Virtual Imaging Trials and Carl E. Ravin Advanced Imaging Laboratories, 2424 Erwin Rd, Suite 302, Durham, NC 27705, USA; Department of Radiology, Duke University, 2301 Erwin Rd, Durham, NC 27705, USA
| | - Jiang Hsieh
- GE Healthcare, 3000 N Grandview Blvd, Waukesha, WI 53188, USA
| | - Ehsan Samei
- Center for Virtual Imaging Trials and Carl E. Ravin Advanced Imaging Laboratories, 2424 Erwin Rd, Suite 302, Durham, NC 27705, USA; Department of Physics, Duke University, Science Drive, Durham, NC 27708, USA; Department of Radiology, Duke University, 2301 Erwin Rd, Durham, NC 27705, USA
| |
Collapse
|
26
|
Im JY, Halliburton SS, Mei K, Perkins AE, Wong E, Roshkovan L, Gang GJ, Noël PB. Lifelike PixelPrint phantoms for assessing clinical image quality and dose reduction capabilities of a deep learning CT reconstruction algorithm. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2024; 12925:129251O. [PMID: 38836183 PMCID: PMC11148728 DOI: 10.1117/12.3006547] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2024]
Abstract
Deep learning CT reconstruction (DLR) has become increasingly popular as a method for improving image quality and reducing radiation exposure. Due to their nonlinear nature, these algorithms result in resolution and noise performance which are object-dependent. Therefore, traditional CT phantoms, which lack realistic tissue morphology, have become inadequate for assessing clinical imaging performance. We propose to utilize 3D-printed PixelPrint phantoms, which exhibit lifelike attenuation profiles, textures, and structures, as a better tool for evaluating DLR performance. In this study, we evaluate a DLR algorithm (Precise Image (PI), Philips Healthcare) using a custom PixelPrint lung phantom and perform head-to-head comparisons between DLR, iterative reconstruction, and filtered back projection (FBP) with scans acquired at a broad range of radiation exposures (CTDIvol: 0.5, 1, 2, 4, 6, 9, 12, 15, 19, and 20 mGy). We compared the performance of each resultant image using noise, peak signal to noise ratio (PSNR), structural similarity index (SSIM), feature-based similarity index (FSIM), information theoretic-based statistic similarity measure (ISSM) and universal image quality index (UIQ). Iterative reconstruction at 9 mGy matches the image quality of FBP at 12 mGy (diagnostic reference level) for all metrics, demonstrating a dose reduction capability of 25%. Meanwhile, DLR matches the image quality of diagnostic reference level FBP images at doses between 4 - 9 mGy, demonstrating dose reduction capabilities between 25% and 67%. This study shows that DLR allows for reduced radiation dose compared to both FBP and iterative reconstruction without compromising image quality. Furthermore, PixelPrint phantoms offer more realistic testing conditions compared to traditional phantoms in the evaluation of novel CT technologies. This, in turn, promotes the translation of new technologies, such as DLR, into clinical practice.
Collapse
Affiliation(s)
- Jessica Y Im
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA
| | | | - Kai Mei
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | | | - Eddy Wong
- Philips Healthcare, Cleveland, OH, USA
| | - Leonid Roshkovan
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | - Grace J Gang
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | - Peter B Noël
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
27
|
Mese I, Altintas Taslicay C, Sivrioglu AK. Synergizing photon-counting CT with deep learning: potential enhancements in medical imaging. Acta Radiol 2024; 65:159-166. [PMID: 38146126 DOI: 10.1177/02841851231217995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2023]
Abstract
This review article highlights the potential of integrating photon-counting computed tomography (CT) and deep learning algorithms in medical imaging to enhance diagnostic accuracy, improve image quality, and reduce radiation exposure. The use of photon-counting CT provides superior image quality, reduced radiation dose, and material decomposition capabilities, while deep learning algorithms excel in automating image analysis and improving diagnostic accuracy. The integration of these technologies can lead to enhanced material decomposition and classification, spectral image analysis, predictive modeling for individualized medicine, workflow optimization, and radiation dose management. However, data requirements, computational resources, and regulatory and ethical concerns remain challenges that need to be addressed to fully realize the potential of this technology. The fusion of photon-counting CT and deep learning algorithms is poised to revolutionize medical imaging and transform patient care.
Collapse
Affiliation(s)
- Ismail Mese
- Department of Radiology, Health Sciences University, Erenkoy Mental Health and Neurology Training and Research Hospital, Istanbul, Turkey
| | | | | |
Collapse
|
28
|
Sadia RT, Chen J, Zhang J. CT image denoising methods for image quality improvement and radiation dose reduction. J Appl Clin Med Phys 2024; 25:e14270. [PMID: 38240466 PMCID: PMC10860577 DOI: 10.1002/acm2.14270] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Revised: 12/15/2023] [Accepted: 12/28/2023] [Indexed: 02/13/2024] Open
Abstract
With the ever-increasing use of computed tomography (CT), concerns about its radiation dose have become a significant public issue. To address the need for radiation dose reduction, CT denoising methods have been widely investigated and applied in low-dose CT images. Numerous noise reduction algorithms have emerged, such as iterative reconstruction and most recently, deep learning (DL)-based approaches. Given the rapid advancements in Artificial Intelligence techniques, we recognize the need for a comprehensive review that emphasizes the most recently developed methods. Hence, we have performed a thorough analysis of existing literature to provide such a review. Beyond directly comparing the performance, we focus on pivotal aspects, including model training, validation, testing, generalizability, vulnerability, and evaluation methods. This review is expected to raise awareness of the various facets involved in CT image denoising and the specific challenges in developing DL-based models.
Collapse
Affiliation(s)
- Rabeya Tus Sadia
- Department of Computer ScienceUniversity of KentuckyLexingtonKentuckyUSA
| | - Jin Chen
- Department of Medicine‐NephrologyUniversity of Alabama at BirminghamBirminghamAlabamaUSA
| | - Jie Zhang
- Department of RadiologyUniversity of KentuckyLexingtonKentuckyUSA
| |
Collapse
|
29
|
Chen Y, Huang Z, Feng L, Zou W, Kong D, Zhu D, Dai G, Zhao W, Zhang Y, Luo M. Deep Learning-Based Reconstruction Improves the Image Quality of Low-Dose CT Colonography. Acad Radiol 2024:S1076-6332(24)00021-7. [PMID: 38290889 DOI: 10.1016/j.acra.2024.01.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 01/11/2024] [Accepted: 01/11/2024] [Indexed: 02/01/2024]
Abstract
RATIONALE AND OBJECTIVES To evaluate the image quality of low-dose CT colonography (CTC) using deep learning-based reconstruction (DLR) compared to iterative reconstruction (IR). MATERIALS AND METHODS Adults included in the study were divided into four groups according to body mass index (BMI). Routine-dose (RD: 120 kVp) CTC images were reconstructed with IR (RD-IR); low-dose (LD: 100kVp) images were reconstructed with IR (LD-IR) and DLR (LD-DLR). The subjective image quality was rated on a 5-point scale by two radiologists independently. The parameters for objective image quality included noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). The Friedman test was used to compare the image quality among RD-IR, LD-IR and LD-DLR. The KruskalWallis test was used to compare the results among different BMI groups. RESULTS A total of 270 volunteers (mean age: 47.94 years ± 11.57; 115 men) were included. The effective dose of low-dose CTC was decreased by approximately 83.18% (5.18mSv ± 0.86 vs. 0.86mSv ± 0.05, P < 0.001). The subjective image quality score of LD-DLR was superior to that of LD-IR (3.61 ± 0.56 vs. 2.70 ± 0.51, P < 0.001) and on par with the RD- IR's (3.61 ± 0.56 vs. 3.74 ± 0.52, P = 0.486). LD-DLR exhibited the lowest noise, and the maximum SNR and CNR compared to RD-IR and LD-IR (all P < 0.001). No statistical difference was found in the noise of LD-DLR images between different BMI groups (all P > 0.05). CONCLUSION Compared to IR, DLR provided low-dose CTC with superior image quality at an average radiation dose of 0.86mSv, which may be promising in future colorectal cancer screening.
Collapse
Affiliation(s)
- Yanshan Chen
- Department of Radiology, the Six Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.); Biomedical Innovation Center, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.); Department of Radiology, Jinling Hospital, the First School of Clinical Medicine, Southern Medical University, Nanjing, Jiangsu 210002, China (Y.C.)
| | - Zixuan Huang
- Department of Radiology, the Six Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.); Biomedical Innovation Center, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.); Department of Radiology, Guangdong Second Traditional Chinese Medicine Hospital, Guangzhou, Guangdong 510095, China (Z.H.)
| | - Lijuan Feng
- Department of Radiology, the Six Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.); Biomedical Innovation Center, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.); Department of Radiology, the First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi 530021, China (L.F.)
| | - Wenbin Zou
- Department of Radiology, the Six Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.); Biomedical Innovation Center, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.)
| | - Decan Kong
- Department of Radiology, the Six Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.); Biomedical Innovation Center, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.)
| | - Dongyun Zhu
- Department of Radiology, the Six Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.); Biomedical Innovation Center, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.)
| | - Guochao Dai
- Medical Imaging Center, the First People's Hospital of Kashi Area, Kashi, Xinjiang 844000, China (G.D.)
| | - Weidong Zhao
- Department of Radiology, the Second Hospital of Shanxi Medical University, Taiyuan, Shanxi 030001, China (W.Z.)
| | - Yuanke Zhang
- School of Computer Science, Qufu Normal University, Rizhao, Shandong 276826, China (Y.Z.)
| | - Mingyue Luo
- Department of Radiology, the Six Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.); Biomedical Innovation Center, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China (Y.C., Z.H., L.F., W.Z., D.K., D.Z., M.L.).
| |
Collapse
|
30
|
Higaki T. [[CT] 5. Various CT Image Reconstruction Methods Applying Deep Learning]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2024; 80:112-117. [PMID: 38246633 DOI: 10.6009/jjrt.2024-2309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2024]
Affiliation(s)
- Toru Higaki
- Graduate School of Advanced Science and Engineering, Hiroshima University
| |
Collapse
|
31
|
Lyu P, Li Z, Chen Y, Wang H, Liu N, Liu J, Zhan P, Liu X, Shang B, Wang L, Gao J. Deep learning reconstruction CT for liver metastases: low-dose dual-energy vs standard-dose single-energy. Eur Radiol 2024; 34:28-38. [PMID: 37532899 DOI: 10.1007/s00330-023-10033-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2022] [Revised: 05/28/2023] [Accepted: 06/05/2023] [Indexed: 08/04/2023]
Abstract
OBJECTIVES To assess image quality and liver metastasis detection of reduced-dose dual-energy CT (DECT) with deep learning image reconstruction (DLIR) compared to standard-dose single-energy CT (SECT) with DLIR or iterative reconstruction (IR). METHODS In this prospective study, two groups of 40 participants each underwent abdominal contrast-enhanced scans with full-dose SECT (120-kVp images, DLIR and IR algorithms) or reduced-dose DECT (40- to 60-keV virtual monochromatic images [VMIs], DLIR algorithm), with 122 and 106 metastases, respectively. Groups were matched by age, sex ratio, body mass index, and cross-sectional area. Noise power spectrum of liver images and task-based transfer function of metastases were calculated to assess the noise texture and low-contrast resolution. The image noise, signal-to-noise ratios (SNR) of liver and portal vein, liver-to-lesion contrast-to-noise ratio (LLR), lesion conspicuity, lesion detection rate, and the subjective image quality metrics were compared between groups on 1.25-mm reconstructed images. RESULTS Compared to 120-kVp images with IR, 40- and 50-keV VMIs with DLIR showed similar noise texture and LLR, similar or higher image noise and low-contrast resolution, improved SNR and lesion conspicuity, and similar or better perceptual image quality. When compared to 120-kVp images with DLIR, 50-keV VMIs with DLIR had similar low-contrast resolution, SNR, LLR, lesion conspicuity, and perceptual image quality but lower frequency noise texture and higher image noise. For the detection of hepatic metastases, reduced-dose DECT by 34% maintained observer lesion detection rates. CONCLUSION DECT assisted with DLIR enables a 34% dose reduction for detecting hepatic metastases while maintaining comparable perceptual image quality to full-dose SECT. CLINICAL RELEVANCE STATEMENT Reduced-dose dual-energy CT with deep learning image reconstruction is as accurate as standard-dose single-energy CT for the detection of liver metastases and saves more than 30% of the radiation dose. KEY POINTS • The 40- and 50-keV virtual monochromatic images (VMIs) with deep learning image reconstruction (DLIR) improved lesion conspicuity compared with 120-kVp images with iterative reconstruction while providing similar or better perceptual image quality. • The 50-keV VMIs with DLIR provided comparable perceptual image quality and lesion conspicuity to 120-kVp images with DLIR. • The reduction of radiation by 34% by DLIR in low-keV VMIs is clinically sufficient for detecting low-contrast hepatic metastases.
Collapse
Affiliation(s)
- Peijie Lyu
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province, China
| | - Zhen Li
- Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province, China
| | - Yan Chen
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province, China
| | - Huixia Wang
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province, China
| | - Nana Liu
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province, China
| | - Jie Liu
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province, China
| | - Pengchao Zhan
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province, China
| | - Xing Liu
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province, China
| | - Bo Shang
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province, China
| | - Luotong Wang
- CT Imaging Research Center, GE Healthcare China, Beijing, China
| | - Jianbo Gao
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province, China.
| |
Collapse
|
32
|
Kawashima H. [[CT] 6. The Current Situation of AI Image Reconstruction in CT]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2024; 80:252-259. [PMID: 38382985 DOI: 10.6009/jjrt.2024-2321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
Affiliation(s)
- Hiroki Kawashima
- Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University
| |
Collapse
|
33
|
Kelly Han B, Binka E, Griffiths E, Hobbs R, Eckhauser A, Husain A, Overman D. Left Ventricular Outflow Tract Obstruction in Congenital Heart Disease: The Role of Cardiovascular Computed Tomography in Surgical Decision Making. Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu 2023; 27:11-18. [PMID: 38522866 DOI: 10.1053/j.pcsu.2023.12.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Revised: 11/17/2023] [Accepted: 12/02/2023] [Indexed: 03/26/2024]
Abstract
Patients with many forms of congenital heart disease (CHD) and hypertrophic cardiomyopathy undergo surgical intervention to relieve left ventricular outflow tract obstruction (LVOTO). Cardiovascular Computed Tomography (CCT) defines the complex pathway from the ventricle to the outflow tract and can be visualized in 2D, 3D, and 4D (3D in motion) to help define the mechanism and physiologic significance of obstruction. Advanced cardiac visualization may aid in surgical planning to relieve obstruction in the left ventricular outflow tract, aortic or neo-aortic valve and the supravalvular space. CCT scanner technology has advanced to achieve submillimeter, isotropic spatial resolution, temporal resolution as low as 66 msec allowing high-resolution imaging even at the fast heart rates and small cardiac structures of pediatric patients ECG gating techniques allow radiation exposure to be targeted to a minimal portion of the cardiac cycle for anatomic imaging, and pulse modulation allows cine imaging with a fraction of radiation given during most of the cardiac cycle, thus reducing radiation dose. Scanning is performed in a single heartbeat or breath hold, minimizing the need for anesthesia or sedation, for which CHD patents are highest risk for an adverse event. Examples of visualization of complex left ventricular outflow tract obstruction in the subaortic, valvar and supravalvular space will be highlighted, illustrating the novel applications of CCT in this patient subset.
Collapse
Affiliation(s)
- B Kelly Han
- Division of Pediatric Cardiology, Primary Children's Hospital, University of Utah, Salt Lake City, Utah.
| | - Edem Binka
- Division of Pediatric Cardiology, Primary Children's Hospital, University of Utah, Salt Lake City, Utah
| | - Eric Griffiths
- Division of Cardiothoracic Surgery, Primary Children's Hospital, University of Utah, Salt Lake City, Utah
| | - Reilly Hobbs
- Division of Cardiothoracic Surgery, Primary Children's Hospital, University of Utah, Salt Lake City, Utah
| | - Aaron Eckhauser
- Division of Cardiothoracic Surgery, Primary Children's Hospital, University of Utah, Salt Lake City, Utah
| | - Adil Husain
- Division of Cardiothoracic Surgery, Primary Children's Hospital, University of Utah, Salt Lake City, Utah
| | - David Overman
- Division of Cardiovascular Surgery, Children's Minnesota, Mayo Clinic-Children's Minnesota Cardiovascular Collaborative, Minnesota
| |
Collapse
|
34
|
Im JY, Halliburton SS, Mei K, Perkins AE, Wong E, Roshkovan L, Sandvold OF, Liu LP, Gang GJ, Noël PB. Patient-derived PixelPrint phantoms for evaluating clinical imaging performance of a deep learning CT reconstruction algorithm. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2023:2023.12.07.23299625. [PMID: 38106064 PMCID: PMC10723564 DOI: 10.1101/2023.12.07.23299625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/19/2023]
Abstract
Objective Deep learning reconstruction (DLR) algorithms exhibit object-dependent resolution and noise performance. Thus, traditional geometric CT phantoms cannot fully capture the clinical imaging performance of DLR. This study uses a patient-derived 3D-printed PixelPrint lung phantom to evaluate a commercial DLR algorithm across a wide range of radiation dose levels. Approach The lung phantom used in this study is based on a patient chest CT scan containing ground glass opacities and was fabricated using PixelPrint 3D-printing technology. The phantom was placed inside two different sized extension rings to mimic a small and medium sized patient and was scanned on a conventional CT scanner at exposures between 0.5 and 20 mGy. Each scan was reconstructed using filtered back projection (FBP), iterative reconstruction, and DLR at five levels of denoising. Image noise, contrast to noise ratio (CNR), root mean squared error (RMSE), structural similarity index (SSIM), and multi-scale SSIM (MS SSIM) were calculated for each image. Main Results DLR demonstrated superior performance compared to FBP and iterative reconstruction for all measured metrics in both phantom sizes, with better performance for more aggressive denoising levels. DLR was estimated to reduce dose by 25-83% in the small phantom and by 50-83% in the medium phantom without decreasing image quality for any of the metrics measured in this study. These dose reduction estimates are more conservative compared to the estimates obtained when only considering noise and CNR with a non-anatomical physics phantom. Significance DLR has the capability of producing diagnostic image quality at up to 83% lower radiation dose which can improve the clinical utility and viability of lower dose CT scans. Furthermore, the PixelPrint phantom used in this study offers an improved testing environment with more realistic tissue structures compared to traditional CT phantoms, allowing for structure-based image quality evaluation beyond noise and contrast-based assessments.
Collapse
|
35
|
Moy L. Top Publications in Radiology, 2023: Our 100th Year. Radiology 2023; 309:e233126. [PMID: 38085075 DOI: 10.1148/radiol.233126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
|
36
|
Lei L, Zhou Y, Guo X, Wang L, Zhao X, Wang H, Ma J, Yue S. The value of a deep learning image reconstruction algorithm in whole-brain computed tomography perfusion in patients with acute ischemic stroke. Quant Imaging Med Surg 2023; 13:8173-8189. [PMID: 38106310 PMCID: PMC10722072 DOI: 10.21037/qims-23-547] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Accepted: 09/19/2023] [Indexed: 12/19/2023]
Abstract
Background Computed tomography perfusion (CTP) and computed tomography angiography (CTA) are valuable tools for diagnosing acute ischemic stroke (AIS). It is essential to obtain high-quality CTP and CTA images in short time. This study aimed to evaluate the image quality and diagnostic performance of brain CTP and CTA images generated from CTP reconstructed by a deep learning image reconstruction (DLIR) algorithm on patients with AIS. Methods The study prospectively enrolled 54 patients with suspected AIS undergoing non-contrast CT and CTP within 24 hours. CTP datasets were reconstructed with three levels of adaptive statistical iterative reconstruction-Veo algorithm [ASIR-V 0% with filtered back projection (FBP), ASIR-V 40%, and ASIR-V 80%] and three levels of DLIR, including low (DLIR-L), medium (DLIR-M), and high (DLIR-H). CTA images were generated using the CTP datasets at the peak arterial phase. Objective parameters including signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and noise reduction rate. Subjective evaluation was assessed according to Abels scoring system. Perfusion parameters and detection accuracy for infarction core lesions were evaluated. The objective and subjective image quality of CTA images were also evaluated. Results All reconstructions produced similar CT values (P>0.05). With the increase of ASIR-V and DLIR reconstruction strength, image noise decreased, while SNR and CNR increased for CTP images, especially in white matter. DLIR-H, DLIR-M, and ASIR-V80% yielded higher subjective scores than did ASIR-V40% and FBP. DLIR-H provided the highest noise reduction rate and detection accuracy. No significant difference was found in conventional parameters, the volume of infarct core, or ischemic penumbra among the 6 groups (P>0.05). The objective evaluation of reconstructed CTA images was comparable in DLIR-H, DLIR-M, and ASIR-V80% (P>0.05). The subjective scores of the DLIR-H and DLIR-M images were higher than those of the other groups, especially ASIR-V40% and FBP (P<0.05). Conclusions Compared with FBP and ASIR-V40%, DLIR-H, DLIR-M, and ASIR-V80% improved the overall image quality of CTP and CTA images to varying degrees. Furthermore, DLIR-H and DLIR-M showed the best performance. DLIR-H is the best choice in diagnosing AIS with improved detection accuracy for cerebral infarction. Reconstructing CTA images using CTP datasets could reduce contrast agent and radiation dose.
Collapse
Affiliation(s)
- Limin Lei
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Yuhan Zhou
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Xiaoxu Guo
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | | | - Xitong Zhao
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Hui Wang
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Jinping Ma
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Songwei Yue
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| |
Collapse
|
37
|
Vedantham S, Tseng HW, Fu Z, Chow HHS. Dedicated Cone-Beam Breast CT: Reproducibility of Volumetric Glandular Fraction with Advanced Image Reconstruction Methods. Tomography 2023; 9:2039-2051. [PMID: 37987346 PMCID: PMC10661286 DOI: 10.3390/tomography9060160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 10/06/2023] [Accepted: 10/20/2023] [Indexed: 11/22/2023] Open
Abstract
Dedicated cone-beam breast computed tomography (CBBCT) is an emerging modality and provides fully three-dimensional (3D) images of the uncompressed breast at an isotropic voxel resolution. In an effort to translate this modality to breast cancer screening, advanced image reconstruction methods are being pursued. Since radiographic breast density is an established risk factor for breast cancer and CBBCT provides volumetric data, this study investigates the reproducibility of the volumetric glandular fraction (VGF), defined as the proportion of fibroglandular tissue volume relative to the total breast volume excluding the skin. Four image reconstruction methods were investigated: the analytical Feldkamp-Davis-Kress (FDK), a compressed sensing-based fast, regularized, iterative statistical technique (FRIST), a fully supervised deep learning approach using a multi-scale residual dense network (MS-RDN), and a self-supervised approach based on Noise-to-Noise (N2N) learning. Projection datasets from 106 women who participated in a prior clinical trial were reconstructed using each of these algorithms at a fixed isotropic voxel size of (0.273 mm3). Each reconstructed breast volume was segmented into skin, adipose, and fibroglandular tissues, and the VGF was computed. The VGF did not differ among the four reconstruction methods (p = 0.167), and none of the three advanced image reconstruction algorithms differed from the standard FDK reconstruction (p > 0.862). Advanced reconstruction algorithms developed for low-dose CBBCT reproduce the VGF to provide quantitative breast density, which can be used for risk estimation.
Collapse
Affiliation(s)
- Srinivasan Vedantham
- Department of Medical Imaging, University of Arizona, Tucson, AZ 85724, USA; (H.W.T.); (Z.F.)
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ 85724, USA
| | - Hsin Wu Tseng
- Department of Medical Imaging, University of Arizona, Tucson, AZ 85724, USA; (H.W.T.); (Z.F.)
| | - Zhiyang Fu
- Department of Medical Imaging, University of Arizona, Tucson, AZ 85724, USA; (H.W.T.); (Z.F.)
| | | |
Collapse
|
38
|
Jensen CT, Wong VK, Wagner-Bartak NA, Liu X, Padmanabhan Nair Sobha R, Sun J, Likhari GS, Gupta S. Accuracy of liver metastasis detection and characterization: Dual-energy CT versus single-energy CT with deep learning reconstruction. Eur J Radiol 2023; 168:111121. [PMID: 37806195 DOI: 10.1016/j.ejrad.2023.111121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 09/08/2023] [Accepted: 09/27/2023] [Indexed: 10/10/2023]
Abstract
PURPOSE To assess whether image quality differences between SECT (single-energy CT) and DECT (dual-energy CT 70 keV) with equivalent radiation doses result in altered detection and characterization accuracy of liver metastases when using deep learning image reconstruction (DLIR), and whether DECT spectral curve usage improves accuracy of indeterminate lesion characterization. METHODS In this prospective Health Insurance Portability and Accountability Act-compliant study (March through August 2022), adult men and non-pregnant adult women with biopsy-proven colorectal cancer and liver metastases underwent SECT (120 kVp) and a DECT (70 keV) portovenous abdominal CT scan using DLIR in the same breath-hold (Revolution CT ES; GE Healthcare). Participants were excluded if consent could not be obtained, if there were nonequivalent radiation doses between the two scans, or if the examination was cancelled/rescheduled. Three radiologists independently performed lesion detection and characterization during two separate sessions (SECT DLIRmedium and DECT DLIRhigh) as well as reported lesion confidence and overall image quality. Hounsfield units were measured. Spectral HU curves were provided for any lesions rated as indeterminate. McNemar's test was used to test the marginal homogeneity in terms of diagnostic sensitivity, accuracy and lesion detection. A generalized estimating equation method was used for categorical outcomes. RESULTS 30 participants (mean age, 58 years ± 11, 21 men) were evaluated. Mean CTDIvol was 34 mGy for both scans. 141 lesions (124 metastases, 17 benign) with a mean size of 0.8 cm ± 0.3 cm were identified. High scores for image quality (scores of 4 or 5) were not significantly different between DECT (N = 71 out of 90 total scores from the three readers) and SECT (N = 62) (OR, 2.01; 95% CI:0.89, 4.57; P = 0.093). Equivalent image noise to SECT DLIRmed (HU SD 10 ± 2) was obtained with DECT DLIRhigh (HU SD 10 ± 3) (P = 1). There was no significant difference in lesion detection between DECT and SECT (140/141 lesions) (99.3%; 95% CI:96.1%, 100%).The mean lesion confidence scores by each reader were 4.2 ± 1.3, 3.9 ± 1.0, and 4.8 ± 0.8 for SECT and 4.1 ± 1.4, 4.0 ± 1.0, and 4.7 ± 0.8 for DECT (odds ratio [OR], 0.83; 95% CI: 0.62, 1.11; P = 0.21). Small lesion (≤5mm) characterization accuracy on SECT and DECT was 89.1% (95% CI:76.4%, 96.4%; 41/46) and 84.8% (71.1%, 93.7%; 39/46), respectively (P = 0.41). Use of spectral HU lesion curves resulted in 34 correct changes in characterizations and no mischaracterizations. CONCLUSION DECT required a higher strength of DLIR to obtain equivalent noise compared to SECT DLIR. At equivalent radiation doses and image noise, there was no significant difference in subjective image quality or observer lesion performance between DECT (70 keV) and SECT. However, DECT spectral HU curves of indeterminate lesions improved characterization.
Collapse
Affiliation(s)
- Corey T Jensen
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX 77030-4009, USA.
| | - Vincenzo K Wong
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX 77030-4009, USA
| | - Nicolaus A Wagner-Bartak
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX 77030-4009, USA
| | - Xinming Liu
- Department of Physics, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX 77030-4009, USA
| | - Renjith Padmanabhan Nair Sobha
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX 77030-4009, USA
| | - Jia Sun
- Department of Biostatistics, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX 77030-4009, USA
| | - Gauruv S Likhari
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX 77030-4009, USA
| | - Shiva Gupta
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX 77030-4009, USA
| |
Collapse
|
39
|
Tatsugami F, Nakaura T, Yanagawa M, Fujita S, Kamagata K, Ito R, Kawamura M, Fushimi Y, Ueda D, Matsui Y, Yamada A, Fujima N, Fujioka T, Nozaki T, Tsuboyama T, Hirata K, Naganawa S. Recent advances in artificial intelligence for cardiac CT: Enhancing diagnosis and prognosis prediction. Diagn Interv Imaging 2023; 104:521-528. [PMID: 37407346 DOI: 10.1016/j.diii.2023.06.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Accepted: 06/20/2023] [Indexed: 07/07/2023]
Abstract
Recent advances in artificial intelligence (AI) for cardiac computed tomography (CT) have shown great potential in enhancing diagnosis and prognosis prediction in patients with cardiovascular disease. Deep learning, a type of machine learning, has revolutionized radiology by enabling automatic feature extraction and learning from large datasets, particularly in image-based applications. Thus, AI-driven techniques have enabled a faster analysis of cardiac CT examinations than when they are analyzed by humans, while maintaining reproducibility. However, further research and validation are required to fully assess the diagnostic performance, radiation dose-reduction capabilities, and clinical correctness of these AI-driven techniques in cardiac CT. This review article presents recent advances of AI in the field of cardiac CT, including deep-learning-based image reconstruction, coronary artery motion correction, automatic calcium scoring, automatic epicardial fat measurement, coronary artery stenosis diagnosis, fractional flow reserve prediction, and prognosis prediction, analyzes current limitations of these techniques and discusses future challenges.
Collapse
Affiliation(s)
- Fuminari Tatsugami
- Department of Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan.
| | - Takeshi Nakaura
- Department of Diagnostic Radiology, Kumamoto University Graduate School of Medicine, 1-1-1 Honjo Chuo-ku, Kumamoto, 860-8556, Japan
| | - Masahiro Yanagawa
- Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita City, Osaka, 565-0871, Japan
| | - Shohei Fujita
- Departmen of Radiology, Graduate School of Medicine and Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Koji Kamagata
- Department of Radiology, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo 113-8421, Japan
| | - Rintaro Ito
- Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, Aichi, 466-8550, Japan
| | - Mariko Kawamura
- Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, Aichi, 466-8550, Japan
| | - Yasutaka Fushimi
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawaharacho, Sakyoku, Kyoto, 606-8507, Japan
| | - Daiju Ueda
- Department of Diagnostic and Interventional Radiology, Graduate School of Medicine, Osaka Metropolitan University, 1-4-3 Asahi-machi, Abeno-ku, Osaka, 545-8585, Japan
| | - Yusuke Matsui
- Department of Radiology, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8558, Japan
| | - Akira Yamada
- Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano, 390-8621, Japan
| | - Noriyuki Fujima
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital N15, W5, Kita-Ku, Sapporo 060-8638, Japan
| | - Tomoyuki Fujioka
- Department of Diagnostic Radiology, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8519, Japan
| | - Taiki Nozaki
- Department of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-Ku, Tokyo, 160-0016, Japan
| | - Takahiro Tsuboyama
- Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita City, Osaka, 565-0871, Japan
| | - Kenji Hirata
- Department of Diagnostic Imaging, Graduate School of Medicine, Hokkaido University, Kita 15 Nishi 7, Kita-Ku, Sapporo, Hokkaido, 060-8648, Japan
| | - Shinji Naganawa
- Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, Aichi, 466-8550, Japan
| |
Collapse
|
40
|
Zhou Z, Gao Y, Zhang W, Zhang N, Wang H, Wang R, Gao Z, Huang X, Zhou S, Dai X, Yang G, Zhang H, Nieman K, Xu L. Deep Learning-based Prediction of Percutaneous Recanalization in Chronic Total Occlusion Using Coronary CT Angiography. Radiology 2023; 309:e231149. [PMID: 37962501 DOI: 10.1148/radiol.231149] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2023]
Abstract
Background CT is helpful in guiding the revascularization of chronic total occlusion (CTO), but manual prediction scores of percutaneous coronary intervention (PCI) success have challenges. Deep learning (DL) is expected to predict success of PCI for CTO lesions more efficiently. Purpose To develop a DL model to predict guidewire crossing and PCI outcomes for CTO using coronary CT angiography (CCTA) and evaluate its performance compared with manual prediction scores. MATERIALS AND METHODS Participants with CTO lesions were prospectively identified from one tertiary hospital between January 2018 and December 2021 as the training set to develop the DL prediction model for PCI of CTO, with fivefold cross validation. The algorithm was tested using an external test set prospectively enrolled from three tertiary hospitals between January 2021 and June 2022 with the same eligibility criteria. All participants underwent preprocedural CCTA within 1 month before PCI. The end points were guidewire crossing within 30 minutes and PCI success of CTO. Results A total of 534 participants (mean age, 57.7 years ± 10.8 [SD]; 417 [78.1%] men) with 565 CTO lesions were included. In the external test set (186 participants with 189 CTOs), the DL model saved 85.0% of the reconstruction and analysis time of manual scores (mean, 73.7 seconds vs 418.2-466.9 seconds) and had higher accuracy than manual scores in predicting guidewire crossing within 30 minutes (DL, 91.0%; CT Registry of Chronic Total Occlusion Revascularization, 61.9%; Korean Multicenter CTO CT Registry [KCCT], 68.3%; CCTA-derived Multicenter CTO Registry of Japan (J-CTO), 68.8%; P < .05) and PCI success (DL, 93.7%; KCCT, 74.6%; J-CTO, 75.1%; P < .05). For DL, the area under the receiver operating characteristic curve was 0.97 (95% CI: 0.89, 0.99) for the training test set and 0.96 (95% CI: 0.90, 0.98) for the external test set. Conclusion The DL prediction model accurately predicted the percutaneous recanalization outcomes of CTO lesions and increased the efficiency of noninvasively grading the difficulty of PCI. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Pundziute-do Prado in this issue.
Collapse
Affiliation(s)
- Zhen Zhou
- From the Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd, Chaoyang District, Beijing 100029, China (Z.Z., Y.G., N.Z., H.W., R.W., L.X.); School of Biomedical Engineering, Sun Yat-Sen University, Guangzhou, China (W.Z., Z.G., H.Z.); Keya Medical Company, Shenzhen, China (X.H.); Department of Cardiology, Chinese PLA General Hospital, Beijing, China (S.Z.); Department of Radiology, The First Hospital of China Medical University, Shenyang, China (X.D.); Cardiovascular Research Centre, Royal Brompton Hospital, London, UK (G.Y.); National Heart and Lung Institute, Imperial College London, London, UK (G.Y.); and Department of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, Calif (K.N.)
| | - Yifeng Gao
- From the Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd, Chaoyang District, Beijing 100029, China (Z.Z., Y.G., N.Z., H.W., R.W., L.X.); School of Biomedical Engineering, Sun Yat-Sen University, Guangzhou, China (W.Z., Z.G., H.Z.); Keya Medical Company, Shenzhen, China (X.H.); Department of Cardiology, Chinese PLA General Hospital, Beijing, China (S.Z.); Department of Radiology, The First Hospital of China Medical University, Shenyang, China (X.D.); Cardiovascular Research Centre, Royal Brompton Hospital, London, UK (G.Y.); National Heart and Lung Institute, Imperial College London, London, UK (G.Y.); and Department of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, Calif (K.N.)
| | - Weiwei Zhang
- From the Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd, Chaoyang District, Beijing 100029, China (Z.Z., Y.G., N.Z., H.W., R.W., L.X.); School of Biomedical Engineering, Sun Yat-Sen University, Guangzhou, China (W.Z., Z.G., H.Z.); Keya Medical Company, Shenzhen, China (X.H.); Department of Cardiology, Chinese PLA General Hospital, Beijing, China (S.Z.); Department of Radiology, The First Hospital of China Medical University, Shenyang, China (X.D.); Cardiovascular Research Centre, Royal Brompton Hospital, London, UK (G.Y.); National Heart and Lung Institute, Imperial College London, London, UK (G.Y.); and Department of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, Calif (K.N.)
| | - Nan Zhang
- From the Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd, Chaoyang District, Beijing 100029, China (Z.Z., Y.G., N.Z., H.W., R.W., L.X.); School of Biomedical Engineering, Sun Yat-Sen University, Guangzhou, China (W.Z., Z.G., H.Z.); Keya Medical Company, Shenzhen, China (X.H.); Department of Cardiology, Chinese PLA General Hospital, Beijing, China (S.Z.); Department of Radiology, The First Hospital of China Medical University, Shenyang, China (X.D.); Cardiovascular Research Centre, Royal Brompton Hospital, London, UK (G.Y.); National Heart and Lung Institute, Imperial College London, London, UK (G.Y.); and Department of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, Calif (K.N.)
| | - Hui Wang
- From the Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd, Chaoyang District, Beijing 100029, China (Z.Z., Y.G., N.Z., H.W., R.W., L.X.); School of Biomedical Engineering, Sun Yat-Sen University, Guangzhou, China (W.Z., Z.G., H.Z.); Keya Medical Company, Shenzhen, China (X.H.); Department of Cardiology, Chinese PLA General Hospital, Beijing, China (S.Z.); Department of Radiology, The First Hospital of China Medical University, Shenyang, China (X.D.); Cardiovascular Research Centre, Royal Brompton Hospital, London, UK (G.Y.); National Heart and Lung Institute, Imperial College London, London, UK (G.Y.); and Department of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, Calif (K.N.)
| | - Rui Wang
- From the Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd, Chaoyang District, Beijing 100029, China (Z.Z., Y.G., N.Z., H.W., R.W., L.X.); School of Biomedical Engineering, Sun Yat-Sen University, Guangzhou, China (W.Z., Z.G., H.Z.); Keya Medical Company, Shenzhen, China (X.H.); Department of Cardiology, Chinese PLA General Hospital, Beijing, China (S.Z.); Department of Radiology, The First Hospital of China Medical University, Shenyang, China (X.D.); Cardiovascular Research Centre, Royal Brompton Hospital, London, UK (G.Y.); National Heart and Lung Institute, Imperial College London, London, UK (G.Y.); and Department of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, Calif (K.N.)
| | - Zhifan Gao
- From the Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd, Chaoyang District, Beijing 100029, China (Z.Z., Y.G., N.Z., H.W., R.W., L.X.); School of Biomedical Engineering, Sun Yat-Sen University, Guangzhou, China (W.Z., Z.G., H.Z.); Keya Medical Company, Shenzhen, China (X.H.); Department of Cardiology, Chinese PLA General Hospital, Beijing, China (S.Z.); Department of Radiology, The First Hospital of China Medical University, Shenyang, China (X.D.); Cardiovascular Research Centre, Royal Brompton Hospital, London, UK (G.Y.); National Heart and Lung Institute, Imperial College London, London, UK (G.Y.); and Department of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, Calif (K.N.)
| | - Xiaomeng Huang
- From the Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd, Chaoyang District, Beijing 100029, China (Z.Z., Y.G., N.Z., H.W., R.W., L.X.); School of Biomedical Engineering, Sun Yat-Sen University, Guangzhou, China (W.Z., Z.G., H.Z.); Keya Medical Company, Shenzhen, China (X.H.); Department of Cardiology, Chinese PLA General Hospital, Beijing, China (S.Z.); Department of Radiology, The First Hospital of China Medical University, Shenyang, China (X.D.); Cardiovascular Research Centre, Royal Brompton Hospital, London, UK (G.Y.); National Heart and Lung Institute, Imperial College London, London, UK (G.Y.); and Department of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, Calif (K.N.)
| | - Shanshan Zhou
- From the Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd, Chaoyang District, Beijing 100029, China (Z.Z., Y.G., N.Z., H.W., R.W., L.X.); School of Biomedical Engineering, Sun Yat-Sen University, Guangzhou, China (W.Z., Z.G., H.Z.); Keya Medical Company, Shenzhen, China (X.H.); Department of Cardiology, Chinese PLA General Hospital, Beijing, China (S.Z.); Department of Radiology, The First Hospital of China Medical University, Shenyang, China (X.D.); Cardiovascular Research Centre, Royal Brompton Hospital, London, UK (G.Y.); National Heart and Lung Institute, Imperial College London, London, UK (G.Y.); and Department of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, Calif (K.N.)
| | - Xu Dai
- From the Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd, Chaoyang District, Beijing 100029, China (Z.Z., Y.G., N.Z., H.W., R.W., L.X.); School of Biomedical Engineering, Sun Yat-Sen University, Guangzhou, China (W.Z., Z.G., H.Z.); Keya Medical Company, Shenzhen, China (X.H.); Department of Cardiology, Chinese PLA General Hospital, Beijing, China (S.Z.); Department of Radiology, The First Hospital of China Medical University, Shenyang, China (X.D.); Cardiovascular Research Centre, Royal Brompton Hospital, London, UK (G.Y.); National Heart and Lung Institute, Imperial College London, London, UK (G.Y.); and Department of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, Calif (K.N.)
| | - Guang Yang
- From the Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd, Chaoyang District, Beijing 100029, China (Z.Z., Y.G., N.Z., H.W., R.W., L.X.); School of Biomedical Engineering, Sun Yat-Sen University, Guangzhou, China (W.Z., Z.G., H.Z.); Keya Medical Company, Shenzhen, China (X.H.); Department of Cardiology, Chinese PLA General Hospital, Beijing, China (S.Z.); Department of Radiology, The First Hospital of China Medical University, Shenyang, China (X.D.); Cardiovascular Research Centre, Royal Brompton Hospital, London, UK (G.Y.); National Heart and Lung Institute, Imperial College London, London, UK (G.Y.); and Department of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, Calif (K.N.)
| | - Heye Zhang
- From the Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd, Chaoyang District, Beijing 100029, China (Z.Z., Y.G., N.Z., H.W., R.W., L.X.); School of Biomedical Engineering, Sun Yat-Sen University, Guangzhou, China (W.Z., Z.G., H.Z.); Keya Medical Company, Shenzhen, China (X.H.); Department of Cardiology, Chinese PLA General Hospital, Beijing, China (S.Z.); Department of Radiology, The First Hospital of China Medical University, Shenyang, China (X.D.); Cardiovascular Research Centre, Royal Brompton Hospital, London, UK (G.Y.); National Heart and Lung Institute, Imperial College London, London, UK (G.Y.); and Department of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, Calif (K.N.)
| | - Koen Nieman
- From the Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd, Chaoyang District, Beijing 100029, China (Z.Z., Y.G., N.Z., H.W., R.W., L.X.); School of Biomedical Engineering, Sun Yat-Sen University, Guangzhou, China (W.Z., Z.G., H.Z.); Keya Medical Company, Shenzhen, China (X.H.); Department of Cardiology, Chinese PLA General Hospital, Beijing, China (S.Z.); Department of Radiology, The First Hospital of China Medical University, Shenyang, China (X.D.); Cardiovascular Research Centre, Royal Brompton Hospital, London, UK (G.Y.); National Heart and Lung Institute, Imperial College London, London, UK (G.Y.); and Department of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, Calif (K.N.)
| | - Lei Xu
- From the Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd, Chaoyang District, Beijing 100029, China (Z.Z., Y.G., N.Z., H.W., R.W., L.X.); School of Biomedical Engineering, Sun Yat-Sen University, Guangzhou, China (W.Z., Z.G., H.Z.); Keya Medical Company, Shenzhen, China (X.H.); Department of Cardiology, Chinese PLA General Hospital, Beijing, China (S.Z.); Department of Radiology, The First Hospital of China Medical University, Shenyang, China (X.D.); Cardiovascular Research Centre, Royal Brompton Hospital, London, UK (G.Y.); National Heart and Lung Institute, Imperial College London, London, UK (G.Y.); and Department of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, Calif (K.N.)
| |
Collapse
|
41
|
Ryan ME, Jaju A. Revolutionizing pediatric neuroimaging: the era of CT, MRI, and beyond. Childs Nerv Syst 2023; 39:2583-2592. [PMID: 37380927 DOI: 10.1007/s00381-023-06041-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/28/2023] [Accepted: 06/17/2023] [Indexed: 06/30/2023]
Abstract
PURPOSE To review the evolution of cross-sectional imaging in pediatric neuroradiology from early developments to current advancements and future directions. METHODS Information was obtained through a PubMed literature search as well as referenced online resources and personal experience from radiologists currently practicing pediatric neuroimaging and those who experienced the era of nascent cross-sectional imaging. RESULTS The advent of computed tomography (CT) and magnetic resonance imaging (MRI) in the 1970s and 1980s brought about a revolutionary shift in the field of medical imaging, neurosurgical and neurological diagnosis. These cross-sectional imaging techniques ushered in a new era by enabling the visualization of soft tissue structures within the brain and spine. Advancements in these imaging modalities have continued at a remarkable pace, now providing not only high high-resolution and 3-dimensional anatomical imaging, but also functional assessment. With each stride forward, CT and MRI have provided clinicians with invaluable insights, improving the accuracy and precision of diagnoses, facilitating the identification of optimal surgical targets, and guiding the selection of appropriate treatment strategies. CONCLUSION This article traces the origins and early developments of CT and MRI, chronicling their journey from pioneering technologies to their current indispensable status in clinical applications and exciting possibilities that lie ahead in the realm of medical imaging and neurologic diagnosis.
Collapse
Affiliation(s)
- Maura E Ryan
- Department of Medical Imaging, Ann and Robert H. Lurie Children's Hospital of Chicago, 225 East Chicago Ave, Chicago, IL, USA.
- Northwestern University Feinberg School of Medicine, 420 East Superior St, Chicago, IL, USA.
| | - Alok Jaju
- Department of Medical Imaging, Ann and Robert H. Lurie Children's Hospital of Chicago, 225 East Chicago Ave, Chicago, IL, USA
- Northwestern University Feinberg School of Medicine, 420 East Superior St, Chicago, IL, USA
| |
Collapse
|
42
|
Abstract
In 1971, the first patient CT examination by Ambrose and Hounsfield paved the way for not only volumetric imaging of the brain but of the entire body. From the initial 5-minute scan for a 180° rotation to today's 0.24-second scan for a 360° rotation, CT technology continues to reinvent itself. This article describes key historical milestones in CT technology from the earliest days of CT to the present, with a look toward the future of this essential imaging modality. After a review of the beginnings of CT and its early adoption, the technical steps taken to decrease scan times-both per image and per examination-are reviewed. Novel geometries such as electron-beam CT and dual-source CT have also been developed in the quest for ever-faster scans and better in-plane temporal resolution. The focus of the past 2 decades on radiation dose optimization and management led to changes in how exposure parameters such as tube current and tube potential are prescribed such that today, examinations are more customized to the specific patient and diagnostic task than ever before. In the mid-2000s, CT expanded its reach from gray-scale to color with the clinical introduction of dual-energy CT. Today's most recent technical innovation-photon-counting CT-offers greater capabilities in multienergy CT as well as spatial resolution as good as 125 μm. Finally, artificial intelligence is poised to impact both the creation and processing of CT images, as well as automating many tasks to provide greater accuracy and reproducibility in quantitative applications.
Collapse
Affiliation(s)
- Cynthia H. McCollough
- Department of Radiology, Mayo Clinic, 200 First St SW Rochester, MN, United States 55905
| | | |
Collapse
|
43
|
Kim CH, Chung MJ, Cha YK, Oh S, Kim KG, Yoo H. The impact of deep learning reconstruction in low dose computed tomography on the evaluation of interstitial lung disease. PLoS One 2023; 18:e0291745. [PMID: 37756357 PMCID: PMC10529569 DOI: 10.1371/journal.pone.0291745] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Accepted: 09/05/2023] [Indexed: 09/29/2023] Open
Abstract
To evaluate the effect of the deep learning model reconstruction (DLM) method in terms of image quality and diagnostic agreement in low-dose computed tomography (LDCT) for interstitial lung disease (ILD), 193 patients who underwent LDCT for suspected ILD were retrospectively reviewed. Datasets were reconstructed using filtered back projection (FBP), adaptive statistical iterative reconstruction Veo (ASiR-V), and DLM. For image quality analysis, the signal, noise, signal-to-noise ratio (SNR), blind/referenceless image spatial quality evaluator (BRISQUE), and visual scoring were evaluated. Also, CT patterns of usual interstitial pneumonia (UIP) were classified according to the 2022 idiopathic pulmonary fibrosis (IPF) diagnostic criteria. The differences between CT images subjected to FBP, ASiR-V 30%, and DLM were evaluated. The image noise and BRISQUE scores of DLM images was lower and SNR was higher than that of the ASiR-V and FBP images (ASiR-V vs. DLM, p < 0.001 and FBP vs. DLR-M, p < 0.001, respectively). The agreement of the diagnostic categorization of IPF between the three reconstruction methods was almost perfect (κ = 0.992, CI 0.990-0.994). Image quality was improved with DLM compared to ASiR-V and FBP.
Collapse
Affiliation(s)
- Chu hyun Kim
- Center for Health Promotion, Samsung Medical Center, Seoul, Republic of Korea
- Department of Radiology and AI Research Center, Samsung Medical Center, Sungkyunkwan University, Seoul, Korea
| | - Myung Jin Chung
- Department of Radiology and AI Research Center, Samsung Medical Center, Sungkyunkwan University, Seoul, Korea
- Department of Data Convergence and Future Medicine, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Yoon Ki Cha
- Department of Radiology and AI Research Center, Samsung Medical Center, Sungkyunkwan University, Seoul, Korea
| | - Seok Oh
- Gil Medical Center, Department of Biomedical Engineering, Gachon University College of Medicine, Incheon, Korea
| | - Kwang gi Kim
- Gil Medical Center, Department of Biomedical Engineering, Gachon University College of Medicine, Incheon, Korea
| | - Hongseok Yoo
- Division of Pulmonary and Critical Care Medicine, Samsung Medical Center, School of Medicine, Sungkyunkwan University, Seoul, South Korea
| |
Collapse
|
44
|
Iwasawa T, Matsushita S, Hirayama M, Baba T, Ogura T. Quantitative Analysis for Lung Disease on Thin-Section CT. Diagnostics (Basel) 2023; 13:2988. [PMID: 37761355 PMCID: PMC10528918 DOI: 10.3390/diagnostics13182988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Revised: 08/30/2023] [Accepted: 09/12/2023] [Indexed: 09/29/2023] Open
Abstract
Thin-section computed tomography (CT) is widely employed not only for assessing morphology but also for evaluating respiratory function. Three-dimensional images obtained from thin-section CT provide precise measurements of lung, airway, and vessel volumes. These volumetric indices are correlated with traditional pulmonary function tests (PFT). CT also generates lung histograms. The volume ratio of areas with low and high attenuation correlates with PFT results. These quantitative image analyses have been utilized to investigate the early stages and disease progression of diffuse lung diseases, leading to the development of novel concepts such as pre-chronic obstructive pulmonary disease (pre-COPD) and interstitial lung abnormalities. Quantitative analysis proved particularly valuable during the COVID-19 pandemic when clinical evaluations were limited. In this review, we introduce CT analysis methods and explore their clinical applications in the context of various lung diseases. We also highlight technological advances, including images with matrices of 1024 × 1024 and slice thicknesses of 0.25 mm, which enhance the accuracy of these analyses.
Collapse
Affiliation(s)
- Tae Iwasawa
- Department of Radiology, Kanagawa Cardiovascular & Respiratory Center, 6-16-1 Tomioka-higashi, Kanazawa-ku, Yokohama 236-0051, Japan; (S.M.); (M.H.)
| | - Shoichiro Matsushita
- Department of Radiology, Kanagawa Cardiovascular & Respiratory Center, 6-16-1 Tomioka-higashi, Kanazawa-ku, Yokohama 236-0051, Japan; (S.M.); (M.H.)
| | - Mariko Hirayama
- Department of Radiology, Kanagawa Cardiovascular & Respiratory Center, 6-16-1 Tomioka-higashi, Kanazawa-ku, Yokohama 236-0051, Japan; (S.M.); (M.H.)
| | - Tomohisa Baba
- Department of Respiratory Medicine, Kanagawa Cardiovascular & Respiratory Center, 6-16-1 Tomioka-higashi, Kanazawa-ku, Yokohama 236-0051, Japan; (T.B.); (T.O.)
| | - Takashi Ogura
- Department of Respiratory Medicine, Kanagawa Cardiovascular & Respiratory Center, 6-16-1 Tomioka-higashi, Kanazawa-ku, Yokohama 236-0051, Japan; (T.B.); (T.O.)
| |
Collapse
|
45
|
Shehata MA, Saad AM, Kamel S, Stanietzky N, Roman-Colon AM, Morani AC, Elsayes KM, Jensen CT. Deep-learning CT reconstruction in clinical scans of the abdomen: a systematic review and meta-analysis. Abdom Radiol (NY) 2023; 48:2724-2756. [PMID: 37280374 DOI: 10.1007/s00261-023-03966-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 05/13/2023] [Accepted: 05/16/2023] [Indexed: 06/08/2023]
Abstract
OBJECTIVE To perform a systematic literature review and meta-analysis of the two most common commercially available deep-learning algorithms for CT. METHODS We used PubMed, Scopus, Embase, and Web of Science to conduct systematic searches for studies assessing the most common commercially available deep-learning CT reconstruction algorithms: True Fidelity (TF) and Advanced intelligent Clear-IQ Engine (AiCE) in the abdomen of human participants since only these two algorithms currently have adequate published data for robust systematic analysis. RESULTS Forty-four articles fulfilled inclusion criteria. 32 studies evaluated TF and 12 studies assessed AiCE. DLR algorithms produced images with significantly less noise (22-57.3% less than IR) but preserved a desirable noise texture with increased contrast-to-noise ratios and improved lesion detectability on conventional CT. These improvements with DLR were similarly noted in dual-energy CT which was only assessed for a single vendor. Reported radiation reduction potential was 35.1-78.5%. Nine studies assessed observer performance with the two dedicated liver lesion studies being performed on the same vendor reconstruction (TF). These two studies indicate preserved low contrast liver lesion detection (> 5 mm) at CTDIvol 6.8 mGy (BMI 23.5 kg/m2) to 12.2 mGy (BMI 29 kg/m2). If smaller lesion detection and improved lesion characterization is needed, a CTDIvol of 13.6-34.9 mGy is needed in a normal weight to obese population. Mild signal loss and blurring have been reported at high DLR reconstruction strengths. CONCLUSION Deep learning reconstructions significantly improve image quality in CT of the abdomen. Assessment of other dose levels and clinical indications is needed. Careful choice of radiation dose levels is necessary, particularly for small liver lesion assessment.
Collapse
Affiliation(s)
- Mostafa A Shehata
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX, 77030-4009, USA
| | | | - Serageldin Kamel
- Department of Lymphoma and Myeloma, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX, 77030-4009, USA
| | - Nir Stanietzky
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX, 77030-4009, USA
| | | | - Ajaykumar C Morani
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX, 77030-4009, USA
| | - Khaled M Elsayes
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX, 77030-4009, USA
| | - Corey T Jensen
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Unit 1473, Houston, TX, 77030-4009, USA.
| |
Collapse
|
46
|
Lell M, Kachelrieß M. Computed Tomography 2.0: New Detector Technology, AI, and Other Developments. Invest Radiol 2023; 58:587-601. [PMID: 37378467 PMCID: PMC10332658 DOI: 10.1097/rli.0000000000000995] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 05/04/2023] [Indexed: 06/29/2023]
Abstract
ABSTRACT Computed tomography (CT) dramatically improved the capabilities of diagnostic and interventional radiology. Starting in the early 1970s, this imaging modality is still evolving, although tremendous improvements in scan speed, volume coverage, spatial and soft tissue resolution, as well as dose reduction have been achieved. Tube current modulation, automated exposure control, anatomy-based tube voltage (kV) selection, advanced x-ray beam filtration, and iterative image reconstruction techniques improved image quality and decreased radiation exposure. Cardiac imaging triggered the demand for high temporal resolution, volume acquisition, and high pitch modes with electrocardiogram synchronization. Plaque imaging in cardiac CT as well as lung and bone imaging demand for high spatial resolution. Today, we see a transition of photon-counting detectors from experimental and research prototype setups into commercially available systems integrated in patient care. Moreover, with respect to CT technology and CT image formation, artificial intelligence is increasingly used in patient positioning, protocol adjustment, and image reconstruction, but also in image preprocessing or postprocessing. The aim of this article is to give an overview of the technical specifications of up-to-date available whole-body and dedicated CT systems, as well as hardware and software innovations for CT systems in the near future.
Collapse
|
47
|
Ohno Y, Ozawa Y, Nagata H, Bando S, Cong S, Takahashi T, Oshima Y, Hamabuchi N, Matsuyama T, Ueda T, Yoshikawa T, Takenaka D, Toyama H. Area-Detector Computed Tomography for Pulmonary Functional Imaging. Diagnostics (Basel) 2023; 13:2518. [PMID: 37568881 PMCID: PMC10416899 DOI: 10.3390/diagnostics13152518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Revised: 07/22/2023] [Accepted: 07/25/2023] [Indexed: 08/13/2023] Open
Abstract
An area-detector CT (ADCT) has a 320-detector row and can obtain isotropic volume data without helical scanning within an area of nearly 160 mm. The actual-perfusion CT data within this area can, thus, be obtained by means of continuous dynamic scanning for the qualitative or quantitative evaluation of regional perfusion within nodules, lymph nodes, or tumors. Moreover, this system can obtain CT data with not only helical but also step-and-shoot or wide-volume scanning for body CT imaging. ADCT also has the potential to use dual-energy CT and subtraction CT to enable contrast-enhanced visualization by means of not only iodine but also xenon or krypton for functional evaluations. Therefore, systems using ADCT may be able to function as a pulmonary functional imaging tool. This review is intended to help the reader understand, with study results published during the last a few decades, the basic or clinical evidence about (1) newly applied reconstruction methods for radiation dose reduction for functional ADCT, (2) morphology-based pulmonary functional imaging, (3) pulmonary perfusion evaluation, (4) ventilation assessment, and (5) biomechanical evaluation.
Collapse
Affiliation(s)
- Yoshiharu Ohno
- Department of Diagnostic Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan
- Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan;
| | - Yoshiyuki Ozawa
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Hiroyuki Nagata
- Joint Research Laboratory of Advanced Medical Imaging, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan;
| | - Shuji Bando
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Shang Cong
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Tomoki Takahashi
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Yuka Oshima
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Nayu Hamabuchi
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Takahiro Matsuyama
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Takahiro Ueda
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| | - Takeshi Yoshikawa
- Department of Diagnostic Radiology, Hyogo Cancer Center, Akashi 673-0021, Hyogo, Japan
| | - Daisuke Takenaka
- Department of Diagnostic Radiology, Hyogo Cancer Center, Akashi 673-0021, Hyogo, Japan
| | - Hiroshi Toyama
- Department of Radiology, Fujita Health University School of Medicine, Toyoake 470-1192, Aichi, Japan; (Y.O.)
| |
Collapse
|
48
|
Pashazadeh A, Hoeschen C. [Opportunities for artificial intelligence in radiation protection : Improving safety of diagnostic imaging]. RADIOLOGIE (HEIDELBERG, GERMANY) 2023; 63:530-538. [PMID: 37347256 PMCID: PMC10299955 DOI: 10.1007/s00117-023-01167-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 05/16/2023] [Indexed: 06/23/2023]
Abstract
CLINICAL/METHODOLOGICAL ISSUE Imaging of structures of internal organs often requires ionizing radiation, which is a health risk. Reducing the radiation dose can increase the image noise, which means that images provide less information. STANDARD RADIOLOGICAL METHODS This problem is observed in commonly used medical imaging modalities such as computed tomography (CT), positron emission tomography (PET), single photon emission computed tomography (SPECT), angiography, fluoroscopy, and any modality that uses ionizing radiation for imaging. METHODOLOGICAL INNOVATIONS Artificial intelligence (AI) can improve the quality of low-dose images and help minimize radiation exposure. Potential applications are explored, and frameworks and procedures are critically evaluated. PERFORMANCE The performance of AI models varies. High-performance models could be used in clinical settings in the near future. Several challenges (e.g., quantitative accuracy, insufficient training data) must be addressed for optimal performance and widespread adoption of this technology in the field of medical imaging. PRACTICAL RECOMMENDATIONS To fully realize the potential of AI and deep learning (DL) in medical imaging, research and development must be intensified. In particular, quality control of AI models must be ensured, and training and testing data must be uncorrelated and quality assured. With sufficient scientific validation and rigorous quality management, AI could contribute to the safe use of low-dose techniques in medical imaging.
Collapse
Affiliation(s)
- Ali Pashazadeh
- Institut für Medizintechnik (IMT), Otto-von-Guericke-Universität Magdeburg, Otto-Hahn-Str. 2, 39016, Magdeburg, Deutschland.
| | - Christoph Hoeschen
- Institut für Medizintechnik (IMT), Otto-von-Guericke-Universität Magdeburg, Otto-Hahn-Str. 2, 39016, Magdeburg, Deutschland
| |
Collapse
|
49
|
Mastrodicasa D, Aquino GJ, Ordovas KG, Vargas D, Fleischmann D, Abbara S, Hanneman K. Radiology: Cardiothoracic Imaging Highlights 2022. Radiol Cardiothorac Imaging 2023; 5:e230042. [PMID: 37404783 PMCID: PMC10316293 DOI: 10.1148/ryct.230042] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 04/07/2023] [Accepted: 05/08/2023] [Indexed: 07/06/2023]
Abstract
Since its inaugural issue in 2019, Radiology: Cardiothoracic Imaging has disseminated the latest scientific advances and technical developments in cardiac, vascular, and thoracic imaging. In this review, we highlight select articles published in this journal between October 2021 and October 2022. The scope of the review encompasses various aspects of coronary artery and congenital heart diseases, vascular diseases, thoracic imaging, and health services research. Key highlights include changes in the revised Coronary Artery Disease Reporting and Data System 2.0, the value of coronary CT angiography in informing prognosis and guiding treatment decisions, cardiac MRI findings after COVID-19 vaccination or infection, high-risk features at CT angiography to identify patients with aortic dissection at risk for late adverse events, and CT-guided fiducial marker placement for preoperative planning for pulmonary nodules. Ongoing research and future directions include photon-counting CT and artificial intelligence applications in cardiovascular imaging. Keywords: Pediatrics, CT Angiography, CT-Perfusion, CT-Spectral Imaging, MR Angiography, PET/CT, Transcatheter Aortic Valve Implantation/Replacement (TAVI/TAVR), Cardiac, Pulmonary, Vascular, Aorta, Coronary Arteries © RSNA, 2023.
Collapse
|